1
|
Nagahawatte ND, Avci R, Paskaranandavadivel N, Cheng LK. High-energy pacing inhibits slow-wave dysrhythmias in the small intestine. Am J Physiol Gastrointest Liver Physiol 2024; 326:G676-G686. [PMID: 38591131 DOI: 10.1152/ajpgi.00254.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 03/18/2024] [Accepted: 04/01/2024] [Indexed: 04/10/2024]
Abstract
The motility of the gastrointestinal tract is coordinated in part by rhythmic slow waves, and disrupted slow-wave patterns are linked to functional motility disorders. At present, there are no treatment strategies that primarily target slow-wave activity. This study assessed the use of pacing to suppress glucagon-induced slow-wave dysrhythmias in the small intestine. Slow waves in the jejunum were mapped in vivo using a high-resolution surface-contact electrode array in pigs (n = 7). Glucagon was intravenously administered to induce hyperglycemia. Slow-wave propagation patterns were categorized into antegrade, retrograde, collision, pacemaker, and uncoupled activity. Slow-wave characteristics such as period, amplitude, and speed were also quantified. Postglucagon infusion, pacing was applied at 4 mA and 8 mA and the resulting slow waves were quantified spatiotemporally. Antegrade propagation was dominant throughout all stages with a prevalence of 55 ± 38% at baseline. However, glucagon infusion resulted in a substantial and significant increase in uncoupled slow waves from 10 ± 8% to 30 ± 12% (P = 0.004) without significantly altering the prevalence of other slow-wave patterns. Slow-wave frequency, amplitude, and speed remained unchanged. Pacing, particularly at 8 mA, significantly suppressed dysrhythmic slow-wave patterns and achieved more effective spatial entrainment (85%) compared with 4 mA (46%, P = 0.039). This study defined the effect of glucagon on jejunal slow waves and identified uncoupling as a key dysrhythmia signature. Pacing effectively entrained rhythmic activity and suppressed dysrhythmias, highlighting the potential of pacing for gastrointestinal disorders associated with slow-wave abnormalities.NEW & NOTEWORTHY Glucagon was infused in pigs to induce hyperglycemia and the resulting slow-wave response in the intact jejunum was defined in high resolution for the first time. Subsequently, with pacing, the glucagon-induced dysrhythmias were suppressed and spatially entrained for the first time with a success rate of 85%. The ability to suppress slow-wave dysrhythmias through pacing is promising in treating motility disorders that are associated with intestinal dysrhythmias.
Collapse
Affiliation(s)
- Nipuni D Nagahawatte
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Recep Avci
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | | | - Leo K Cheng
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
- Department of Surgery, Vanderbilt University, Nashville, Tennessee, United States
- Riddet Institute Centre of Research Excellence, Palmerston North, New Zealand
| |
Collapse
|
2
|
Nagahawatte ND, Avci R, Paskaranandavadivel N, Cheng LK. Optimization of pacing parameters to entrain slow wave activity in the pig jejunum. Sci Rep 2024; 14:6038. [PMID: 38472365 DOI: 10.1038/s41598-024-56256-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Accepted: 03/04/2024] [Indexed: 03/14/2024] Open
Abstract
Pacing has been proposed as a therapy to restore function in motility disorders associated with electrical dysrhythmias. The spatial response of bioelectrical activity in the small intestine to pacing is poorly understood due to a lack of high-resolution investigations. This study systematically varied pacing parameters to determine the optimal settings for the spatial entrainment of slow wave activity in the jejunum. An electrode array was developed to allow simultaneous pacing and high-resolution mapping of the small intestine. Pacing parameters including pulse-width (50, 100 ms), pulse-amplitude (2, 4, 8 mA) and pacing electrode orientation (antegrade, retrograde, circumferential) were systematically varied and applied to the jejunum (n = 15 pigs). Pulse-amplitudes of 4 mA (p = 0.012) and 8 mA (p = 0.002) were more effective than 2 mA in achieving spatial entrainment while pulse-widths of 50 ms and 100 ms had comparable effects (p = 0.125). A pulse-width of 100 ms and a pulse-amplitude of 4 mA were determined to be most effective for slow wave entrainment when paced in the antegrade or circumferential direction with a success rate of greater than 75%. These settings can be applied in chronic studies to evaluate the long-term efficacy of pacing, a critical aspect in determining its therapeutic potential.
Collapse
Affiliation(s)
- Nipuni D Nagahawatte
- Auckland Bioengineering Institute, University of Auckland, Private Bag 92019, Auckland, 1142, New Zealand
| | - Recep Avci
- Auckland Bioengineering Institute, University of Auckland, Private Bag 92019, Auckland, 1142, New Zealand
| | | | - Leo K Cheng
- Auckland Bioengineering Institute, University of Auckland, Private Bag 92019, Auckland, 1142, New Zealand.
- Department of Surgery, Vanderbilt University, Nashville, TN, USA.
- Riddet Institute Centre of Research Excellence, Palmerston North, New Zealand.
| |
Collapse
|
3
|
Drake CE, Cheng LK, Muszynski ND, Somarajan S, Paskaranandavadivel N, Angeli-Gordon TR, Du P, Bradshaw LA, Avci R. Electroanatomical mapping of the stomach with simultaneous biomagnetic measurements. Comput Biol Med 2023; 165:107384. [PMID: 37633085 DOI: 10.1016/j.compbiomed.2023.107384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 07/17/2023] [Accepted: 08/14/2023] [Indexed: 08/28/2023]
Abstract
Gastric motility is coordinated by bioelectric slow waves (SWs) and dysrhythmic SW activity has been linked with motility disorders. Magnetogastrography (MGG) is the non-invasive measurement of the biomagnetic fields generated by SWs. Dysrhythmia identification using MGG is currently challenging because source models are not well developed and the impact of anatomical variation is not well understood. A novel method for the quantitative spatial co-registration of serosal SW potentials, MGG, and geometric models of anatomical structures was developed and performed on two anesthetized pigs to verify feasibility. Electrode arrays were localized using electromagnetic transmitting coils. Coil localization error for the volume where the stomach is normally located under the sensor array was assessed in a benchtop experiment, and mean error was 4.2±2.3mm and 3.6±3.3° for a coil orientation parallel to the sensor array and 6.2±5.7mm and 4.5±7.0° for a perpendicular coil orientation. Stomach geometries were reconstructed by fitting a generic stomach to up to 19 localization coils, and SW activation maps were mapped onto the reconstructed geometries using the registered positions of 128 electrodes. Normal proximal-to-distal and ectopic SW propagation patterns were recorded from the serosa and compared against the simultaneous MGG measurements. Correlations between the center-of-gravity of normalized MGG and the mean position of SW activity on the serosa were 0.36 and 0.85 for the ectopic and normal propagation patterns along the proximal-distal stomach axis, respectively. This study presents the first feasible method for the spatial co-registration of MGG, serosal SW measurements, and subject-specific anatomy. This is a significant advancement because these data enable the development and validation of novel non-invasive gastric source characterization methods.
Collapse
Affiliation(s)
- Chad E Drake
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Leo K Cheng
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand; Department of Surgery, Vanderbilt University, Nashville, TN, USA
| | | | | | | | | | - Peng Du
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | | | - Recep Avci
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.
| |
Collapse
|
4
|
Drake CE, Cheng LK, Paskaranandavadivel N, Alighaleh S, Angeli-Gordon TR, Du P, Bradshaw LA, Avci R. Stomach Geometry Reconstruction Using Serosal Transmitting Coils and Magnetic Source Localization. IEEE Trans Biomed Eng 2023; 70:1036-1044. [PMID: 36121949 PMCID: PMC10069741 DOI: 10.1109/tbme.2022.3207770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE Bioelectric slow waves (SWs) are a key regulator of gastrointestinal motility, and disordered SW activity has been linked to motility disorders. There is currently a lack of practical options for the acquisition of the 3D stomach geometry during research studies when medical imaging is challenging. Accurately recording the geometry of the stomach and co-registering electrode and sensor positions would provide context for in-vivo studies and aid the development of non-invasive methods of gastric SW assessment. METHODS A stomach geometry reconstruction method based on the localization of transmitting coils placed on the gastric serosa was developed. The positions and orientations of the coils, which represented boundary points and surface-normal vectors, were estimated using a magnetic source localization algorithm. Coil localization results were then used to generate surface models. The reconstruction method was evaluated against four 3D-printed anatomically realistic human stomach models and applied in a proof of concept in-vivo pig study. RESULTS Over ten repeated reconstructions, average Hausdorff distance and average surface-normal vector error values were 4.7 ±0.2 mm and 18.7 ±0.7° for the whole stomach, and 3.6 ±0.2 mm and 14.6 ±0.6° for the corpus. Furthermore, mean intra-array localization error was 1.4 ±1.1 mm for the benchtop experiment and 1.7 ±1.6 mm in-vivo. CONCLUSION AND SIGNIFICANCE Results demonstrated that the proposed reconstruction method is accurate and feasible. The stomach models generated by this method, when co-registered with electrode and sensor positions, could enable the investigation and validation of novel inverse analysis techniques.
Collapse
|
5
|
Ding F, Guo R, Cui ZY, Hu H, Zhao G. Clinical application and research progress of extracellular slow wave recording in the gastrointestinal tract. World J Gastrointest Surg 2022; 14:544-555. [PMID: 35979419 PMCID: PMC9258241 DOI: 10.4240/wjgs.v14.i6.544] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Revised: 03/21/2022] [Accepted: 05/17/2022] [Indexed: 02/06/2023] Open
Abstract
The physiological function of the gastrointestinal (GI) tract is based on the slow wave generated and transmitted by the interstitial cells of Cajal. Extracellular myoelectric recording techniques are often used to record the characteristics and propagation of slow wave and analyze the models of slow wave transmission under physiological and pathological conditions to further explore the mechanism of GI dysfunction. This article reviews the application and research progress of electromyography, bioelectromagnetic technology, and high-resolution mapping in animal and clinical experiments, summarizes the clinical application of GI electrical stimulation therapy, and reviews the electrophysiological research in the biliary system.
Collapse
Affiliation(s)
- Fan Ding
- Center of Gallbladder Disease, East Hospital of Tongji University, Shanghai 200120, China
- Institute of Gallstone Disease, Tongji University School of Medicine, Shanghai 200331, China
| | - Run Guo
- Department of Ultrasonography, East Hospital of Tongji University, Shanghai 200120, China
| | - Zheng-Yu Cui
- Department of Internal Medicine of Traditional Chinese Medicine, East Hospital of Tongji University, Shanghai 200120, China
| | - Hai Hu
- Center of Gallbladder Disease, East Hospital of Tongji University, Shanghai 200120, China
- Institute of Gallstone Disease, Tongji University School of Medicine, Shanghai 200331, China
| | - Gang Zhao
- Center of Gallbladder Disease, East Hospital of Tongji University, Shanghai 200120, China
- Institute of Gallstone Disease, Tongji University School of Medicine, Shanghai 200331, China
| |
Collapse
|
6
|
Aghababaie Z, Cheng LK, Paskaranandavadivel N, Avci R, Chan CHA, Matthee A, Amirapu S, Asirvatham SJ, Farrugia G, Beyder A, O’Grady G, Angeli-Gordon TR. Targeted ablation of gastric pacemaker sites to modulate patterns of bioelectrical slow wave activation and propagation in an anesthetized pig model. Am J Physiol Gastrointest Liver Physiol 2022; 322:G431-G445. [PMID: 35137624 PMCID: PMC8917929 DOI: 10.1152/ajpgi.00332.2021] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Gastric motility is coordinated by underlying bioelectrical slow waves. Gastric dysrhythmias occur in gastrointestinal (GI) motility disorders, but there are no validated methods for eliminating dysrhythmias. We hypothesized that targeted ablation could eliminate pacemaker sites in the stomach, including dysrhythmic ectopic pacemaker sites. In vivo high-resolution serosal electrical mapping (16 × 16 electrodes; 6 × 6 cm) was applied to localize normal and ectopic gastric pacemaker sites in 13 anesthetized pigs. Radiofrequency ablation was performed in a square formation surrounding the pacemaker site. Postablation high-resolution mapping revealed that ablation successfully induced localized conduction blocks after 18 min (SD 5). Normal gastric pacemaker sites were eliminated by ablation (n = 6), resulting in the emergence of a new pacemaker site immediately distal to the original site in all cases. Ectopic pacemaker sites were similarly eliminated by ablation in all cases (n = 7), and the surrounding mapped area was then entrained by normal antegrade activity in five of those cases. Histological analysis showed that ablation lesions extended through the entire depth of the muscle layer. Immunohistochemical staining confirmed localized interruption of the interstitial cell of Cajal (ICC) network through the ablation lesions. This study demonstrates that targeted gastric ablation can effectively modulate gastric electrical activation, including eliminating ectopic sites of slow wave activation underlying gastric dysrhythmias, without disrupting surrounding conduction capability or tissue structure. Gastric ablation presents a powerful new research tool for modulating gastric electrical activation and may likely hold therapeutic potential for disorders of gastric function.NEW & NOTEWORTHY This study presents gastric ablation as a novel tool for modulating gastric bioelectrical activation, including eliminating the normal gastric pacemaker site as well as abnormal ectopic pacemaker sites underlying gastric dysrhythmias. Targeted application of radiofrequency ablation was able to eliminate these pacemaker sites without disrupting surrounding conduction capability or tissue structure. Gastric ablation presents a powerful new research tool for modulating gastric electrical activation and may likely hold therapeutic potential for disorders of gastric function.
Collapse
Affiliation(s)
- Zahra Aghababaie
- 1Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Leo K. Cheng
- 1Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand,2Department of Surgery, Vanderbilt University, Nashville, Tennessee
| | | | - Recep Avci
- 1Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | | | - Ashton Matthee
- 1Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Satya Amirapu
- 3Histology Laboratory, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | | | - Gianrico Farrugia
- 5Division of Gastroenterology and Hepatology and Enteric Neurosciences Program, Mayo Clinic, Rochester, Minnesota
| | - Arthur Beyder
- 5Division of Gastroenterology and Hepatology and Enteric Neurosciences Program, Mayo Clinic, Rochester, Minnesota
| | - Gregory O’Grady
- 1Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand,6Department of Surgery, University of Auckland, Auckland, New Zealand
| | - Timothy R. Angeli-Gordon
- 1Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand,6Department of Surgery, University of Auckland, Auckland, New Zealand
| |
Collapse
|
7
|
Chan CHA, Aghababaie Z, Paskaranandavadivel N, Avci R, Cheng LK, Angeli-Gordon TR. Localized gastric distension disrupts slow-wave entrainment leading to temporary ectopic propagation: a high-resolution electrical mapping study. Am J Physiol Gastrointest Liver Physiol 2021; 321:G656-G667. [PMID: 34612062 DOI: 10.1152/ajpgi.00219.2021] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Gastric distension is known to affect normal slow-wave activity and gastric function, but links between slow-wave dysrhythmias and stomach function are poorly understood. Low-resolution mapping is unable to capture complex spatial properties of gastric dysrhythmias, necessitating the use of high-resolution mapping techniques. Characterizing the nature of these dysrhythmias has implications in the understanding of postprandial function and the development of new mapping devices. In this two-phase study, we developed and implemented a protocol for measuring electrophysiological responses to gastric distension in porcine experiments. In vivo, serosal high-resolution electrical mapping (256 electrodes; 36 cm2) was performed in anaesthetized pigs (n = 11), and slow-wave pattern, velocity, frequency, and amplitude were quantified before, during, and after intragastric distension. Phase I experiments (n = 6) focused on developing and refining the distension mapping methods using a surgically inserted intragastric balloon, with a variety of balloon types and distension protocols. Phase II experiments (n = 5) used barostat-controlled 500-mL isovolumetric distensions of an endoscopically introduced intragastric balloon. Dysrhythmias were consistently induced in all five gastric distensions, using refined distension protocols. Dysrhythmias appeared 23 s (SD = 5 s) after the distension and lasted 129 s (SD = 72 s), which consisted of ectopic propagation originating from the greater curvature in the region of distension. In summary, our results suggest that distension disrupts gastric entrainment, inducing temporary ectopic slow-wave propagation. These results may influence the understanding of the postprandial stomach and electrophysiological effects of gastric interventions.NEW & NOTEWORTHY This study presents the discovery of temporary dysrhythmic ectopic pacemakers in the distal stomach caused by localized gastric distension. Distension-induced dysrhythmias are an interesting physiological phenomenon that can inform the design of new interventional and electrophysiological protocols for both research and the clinic. The observation of distension-induced dysrhythmias also contributes to our understanding of stretch-sensitivity in the gut and may play an important role in normal and abnormal postprandial physiology.
Collapse
Affiliation(s)
| | - Zahra Aghababaie
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Niranchan Paskaranandavadivel
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.,Department of Surgery, University of Auckland, Auckland, New Zealand
| | - Recep Avci
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Leo K Cheng
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.,Department of Surgery, Vanderbilt University, Nashville, Tennessee
| | - Timothy R Angeli-Gordon
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.,Department of Surgery, University of Auckland, Auckland, New Zealand
| |
Collapse
|
8
|
Varghese C, Carson DA, Bhat S, Hayes TCL, Gharibans AA, Andrews CN, O'Grady G. Clinical associations of functional dyspepsia with gastric dysrhythmia on electrogastrography: A comprehensive systematic review and meta-analysis. Neurogastroenterol Motil 2021; 33:e14151. [PMID: 33830590 DOI: 10.1111/nmo.14151] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 01/30/2021] [Accepted: 03/23/2021] [Indexed: 12/12/2022]
Abstract
BACKGROUND Functional dyspepsia (FD) is a common gastroduodenal disorder, yet its pathophysiology remains poorly understood. Bioelectrical gastric slow-wave abnormalities are thought to contribute to its multifactorial pathophysiology. Electrogastrography (EGG) has been used to record gastric electrical activity; however, the clinical associations require further evaluation. AIMS This study aimed to systematically assess the clinical associations of EGG in FD. METHODS MEDLINE, EMBASE, and CENTRAL databases were systematically searched for articles using EGG in adults with FD. Primary outcomes were percentage normal versus abnormal rhythm (bradygastria, normogastria, and tachygastria). Secondary outcomes were dominant power, dominant frequency, percentage coupling, and the meal responses. RESULTS 1751 FD patients and 555 controls from 47 studies were included. FD patients spent less time in normogastria while fasted (SMD -0.74; 95%CI -1.22 to -0.25) and postprandially (-0.86; 95%CI -1.35 to -0.37) compared with controls. FD patients also spent more fasted time in bradygastria (0.63; 95%CI 0.33-0.93) and tachygastria (0.45; 95%CI 0.12-0.78%). The power ratio (-0.17; 95%CI -0.83-0.48) and dominant frequency meal-response ratio (0.06; 95%CI -0.08-0.21) were not significantly different to controls. Correlations between EGG metrics and the presence and timing of FD symptoms were inconsistent. EGG methodologies were diverse and variably applied. CONCLUSION Abnormal gastric slow-wave rhythms are a consistent abnormality present in FD, as defined by EGG and, therefore, likely play a role in pathophysiology. The aberrant electrophysiology identified in FD warrants further investigation, including into underlying mechanisms, associated spatial patterns, and symptom correlations.
Collapse
Affiliation(s)
- Chris Varghese
- Department of Surgery, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand
| | - Daniel A Carson
- Department of Surgery, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand
| | - Sameer Bhat
- Department of Surgery, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand
| | - Tommy C L Hayes
- Department of Surgery, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand
| | - Armen A Gharibans
- Department of Surgery, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand.,Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | | | - Greg O'Grady
- Department of Surgery, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand.,Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| |
Collapse
|
9
|
O'Grady G, Gharibans AA, Du P, Huizinga JD. The gastric conduction system in health and disease: a translational review. Am J Physiol Gastrointest Liver Physiol 2021; 321:G527-G542. [PMID: 34549598 DOI: 10.1152/ajpgi.00065.2021] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Gastric peristalsis is critically dependent on an underlying electrical conduction system. Recent years have witnessed substantial progress in clarifying the operations of this system, including its pacemaking units, its cellular architecture, and slow-wave propagation patterns. Advanced techniques have been developed for assessing its functions at high spatiotemporal resolutions. This review synthesizes and evaluates this progress, with a focus on human and translational physiology. A current conception of the initiation and conduction of slow-wave activity in the human stomach is provided first, followed by a detailed discussion of its organization at the cellular and tissue level. Particular emphasis is then given to how gastric electrical disorders may contribute to disease states. Gastric dysfunction continues to grow in their prevalence and impact, and while gastric dysrhythmia is established as a clear and pervasive feature in several major gastric disorders, its role in explaining pathophysiology and informing therapy is still emerging. New insights from high-resolution gastric mapping are evaluated, together with historical data from electrogastrography, and the physiological relevance of emerging biomarkers from body surface mapping such as retrograde propagating slow waves. Knowledge gaps requiring further physiological research are highlighted.
Collapse
Affiliation(s)
- Gregory O'Grady
- Department of Surgery, The University of Auckland, Auckland, New Zealand.,Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Armen A Gharibans
- Department of Surgery, The University of Auckland, Auckland, New Zealand.,Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Peng Du
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Jan D Huizinga
- Department of Medicine, Farncombe Family Digestive Health Research Institute, McMaster University, Hamilton, Ontario, Canada
| |
Collapse
|
10
|
Cheng LK, Nagahawatte ND, Avci R, Du P, Liu Z, Paskaranandavadivel N. Strategies to Refine Gastric Stimulation and Pacing Protocols: Experimental and Modeling Approaches. Front Neurosci 2021; 15:645472. [PMID: 33967679 PMCID: PMC8100207 DOI: 10.3389/fnins.2021.645472] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Accepted: 03/22/2021] [Indexed: 12/13/2022] Open
Abstract
Gastric pacing and stimulation strategies were first proposed in the 1960s to treat motility disorders. However, there has been relatively limited clinical translation of these techniques. Experimental investigations have been critical in advancing our understanding of the control mechanisms that innervate gut function. In this review, we will discuss the use of pacing to modulate the rhythmic slow wave conduction patterns generated by interstitial cells of Cajal in the gastric musculature. In addition, the use of gastric high-frequency stimulation methods that target nerves in the stomach to either inhibit or enhance stomach function will be discussed. Pacing and stimulation protocols to modulate gastric activity, effective parameters and limitations in the existing studies are summarized. Mathematical models are useful to understand complex and dynamic systems. A review of existing mathematical models and techniques that aim to help refine pacing and stimulation protocols are provided. Finally, some future directions and challenges that should be investigated are discussed.
Collapse
Affiliation(s)
- Leo K Cheng
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.,Department of General Surgery, Vanderbilt University Medical Center, Nashville, TN, United States.,Riddet Institute, Palmerston North, New Zealand
| | - Nipuni D Nagahawatte
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Recep Avci
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Peng Du
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Zhongming Liu
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States.,Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI, United States
| | | |
Collapse
|
11
|
Carson DA, O'Grady G, Du P, Gharibans AA, Andrews CN. Body surface mapping of the stomach: New directions for clinically evaluating gastric electrical activity. Neurogastroenterol Motil 2021; 33:e14048. [PMID: 33274564 DOI: 10.1111/nmo.14048] [Citation(s) in RCA: 45] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Revised: 10/11/2020] [Accepted: 11/03/2020] [Indexed: 12/12/2022]
Abstract
BACKGROUND Gastric motility disorders, which include both functional and organic etiologies, are highly prevalent. However, there remains a critical lack of objective biomarkers to guide efficient diagnostics and personalized therapies. Bioelectrical activity plays a fundamental role in coordinating gastric function and has been investigated as a contributing mechanism to gastric dysmotility and sensory dysfunction for a century. However, conventional electrogastrography (EGG) has not achieved common clinical adoption due to its perceived limited diagnostic capability and inability to impact clinical care. The last decade has seen the emergence of novel high-resolution methods for invasively mapping human gastric electrical activity in health and disease, providing important new insights into gastric physiology. The limitations of EGG have also now become clearer, including the finding that slow-wave frequency alone is not a reliable discriminator of gastric dysrhythmia, shifting focus instead toward altered spatial patterns. Recently, advances in bioinstrumentation, signal processing, and computational modeling have aligned to allow non-invasive body surface mapping of the stomach to detect spatiotemporal gastric dysrhythmias. The clinical relevance of this emerging strategy to improve diagnostics now awaits determination. PURPOSE This review evaluates these recent advances in clinical gastric electrophysiology, together with promising emerging data suggesting that novel gastric electrical signatures recorded at the body surface (termed "body surface mapping") may correlate with symptoms. Further technological progress and validation data are now awaited to determine whether these advances will deliver on the promise of clinical gastric electrophysiology diagnostics.
Collapse
Affiliation(s)
- Daniel A Carson
- Department of Surgery, University of Auckland, Auckland, New Zealand
| | - Greg O'Grady
- Department of Surgery, University of Auckland, Auckland, New Zealand.,Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Peng Du
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.,Department of Engineering Science, University of Auckland, Auckland, New Zealand
| | - Armen A Gharibans
- Department of Surgery, University of Auckland, Auckland, New Zealand.,Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | | |
Collapse
|
12
|
Wang TH, Angeli TR, Ishida S, Du P, Gharibans A, Paskaranandavadivel N, Imai Y, Miyagawa T, Abell TL, Farrugia G, Cheng LK, O’Grady G. The influence of interstitial cells of Cajal loss and aging on slow wave conduction velocity in the human stomach. Physiol Rep 2021; 8:e14659. [PMID: 33355992 PMCID: PMC7757374 DOI: 10.14814/phy2.14659] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Revised: 11/08/2020] [Accepted: 11/09/2020] [Indexed: 12/14/2022] Open
Abstract
Loss of interstitial cells of Cajal (ICC) has been associated with gastric dysfunction and is also observed during normal aging at ~13% reduction per decade. The impact of ICC loss on gastric slow wave conduction velocity is currently undefined. This study correlated human gastric slow wave velocity with ICC loss and aging. High-resolution gastric slow wave mapping data were screened from a database of 42 patients with severe gastric dysfunction (n = 20) and controls (n = 22). Correlations were performed between corpus slow wave conduction parameters (frequency, velocity, and amplitude) and corpus ICC counts in patients, and with age in controls. Physiological parameters were further integrated into computational models of gastric mixing. Patients: ICC count demonstrated a negative correlation with slow wave velocity in the corpus (i.e., higher velocities with reduced ICC; r2 = .55; p = .03). ICC count did not correlate with extracellular slow wave amplitude (p = .12) or frequency (p = .84). Aging: Age was positively correlated with slow wave velocity in the corpus (range: 25-74 years; r2 = .32; p = .02). Age did not correlate with extracellular slow wave amplitude (p = .40) or frequency (p = .34). Computational simulations demonstrated that the gastric emptying rate would increase at higher slow wave velocities. ICC loss and aging are associated with a higher slow wave velocity. The reason for these relationships is unexplained and merit further investigation. Increased slow wave velocity may modulate gastric emptying higher, although in gastroparesis other pathological factors must dominate to prevent emptying.
Collapse
Affiliation(s)
| | - Timothy R. Angeli
- Auckland Bioengineering InstituteUniversity of AucklandAucklandNew Zealand
| | | | - Peng Du
- Auckland Bioengineering InstituteUniversity of AucklandAucklandNew Zealand
| | - Armen Gharibans
- Department of SurgeryUniversity of AucklandAucklandNew Zealand
- Auckland Bioengineering InstituteUniversity of AucklandAucklandNew Zealand
| | | | - Yohsuke Imai
- Graduate School of EngineeringKobe UniversityKobeJapan
| | - Taimei Miyagawa
- Graduate School of Science and TechnologyHirosaki UniversityHirosakiJapan
| | - Thomas L. Abell
- Division of GastroenterologyUniversity of LouisvilleLouisvilleKYUSA
| | | | - Leo K. Cheng
- Auckland Bioengineering InstituteUniversity of AucklandAucklandNew Zealand
| | - Gregory O’Grady
- Department of SurgeryUniversity of AucklandAucklandNew Zealand
- Auckland Bioengineering InstituteUniversity of AucklandAucklandNew Zealand
| |
Collapse
|
13
|
Eichler CE, Cheng LK, Paskaranandavadivel N, Du P, Bradshaw LA, Avci R. Effects of magnetogastrography sensor configurations in tracking slow wave propagation. Comput Biol Med 2020; 129:104169. [PMID: 33338892 DOI: 10.1016/j.compbiomed.2020.104169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 11/19/2020] [Accepted: 12/03/2020] [Indexed: 10/22/2022]
Abstract
Magnetogastrography (MGG) is a non-invasive method of assessing gastric slow waves (SWs) by recording the resultant magnetic fields. MGG can capture both SW frequency and propagation, and identify SW dysrhythmias that are associated with motility disorders. However, the impact of the restricted spatial coverage and sensor density on SW propagation tracking performance is unknown. This study simulated MGG using multiple anatomically specific torso geometries and two realistic SW propagation patterns to determine the effect of different sensor configurations on tracking SW propagation. The surface current density mapping and center-of-gravity tracking methods were used to compare four magnetometer array configurations: a reference system currently used in GI research and three hypothetical higher density and coverage arrays. SW propagation patterns identified with two hypothetical arrays (with coverage over at least the anterior of the torso) correlated significantly higher with simulated realistic 3 cycle-per-minute SW activity than the reference array (p = 0.016, p = 0.005). Furthermore, results indicated that most of the magnetic fields that contribute to the performance of SW propagation tracking were located on the anterior of the torso as further increasing the coverage did not significantly increase performance. A 30% decrease in sensor spacing within the same spatial coverage of the reference array also significantly increased correlation values by approximately 0.50 when the signal-to-noise ratio was 5 dB. This study provides evidence that higher density and coverage sensor layouts will improve the utility of MGG. Further work is required to investigate optimum sensor configurations across larger anatomical variations and other SW propagation patterns.
Collapse
Affiliation(s)
- Chad E Eichler
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Leo K Cheng
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand; Department of Surgery, Vanderbilt University, Nashville, TN, USA
| | | | - Peng Du
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | | | - Recep Avci
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.
| |
Collapse
|
14
|
Eichler CE, Cheng LK, Du P, Calder S, Paskaranandavadivel N, Bradshaw LA, Avci R. Simulation-based Analysis of Magnetogastrography Sensor Configurations for Characterizing Gastric Slow Wave Dysrhythmias. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:2512-2515. [PMID: 33018517 DOI: 10.1109/embc44109.2020.9175406] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The routine diagnosis of gastric motility disorders represents a significant problem to current clinical practice. Magnetogastrography (MGG) provides a non-invasive option for assessing gastric slow wave (SW) dysrhythmias that are associated with motility disorders. However, its ability to characterize SW propagation is impaired by the limited spatial coverage of existing superconducting quantum interference devices (SQUIDs). Recently developed optically-pumped magnetometers can potentially substitute SQUIDs and enable subject-specific MGG arrays with greater spatial coverage. This study developed simulations of gastric MGG to determine the distribution of the magnetic fields (MFs) generated by SWs above the torso, and investigated the impact of several realistic dysrhythmic patterns of propagation. The distribution of MFs was found to vary significantly for different patterns of SW propagation, with ectopic dysrhythmia displaying the greatest difference from normal. Notably, some important proportion of the MFs lay outside the coverage of an existing experimental SQUID array used in gastrointestinal research for some simulated SW propagation patterns, such as retrograde activity. Results suggest that MGG measurements should be made over the entire frontal face of the torso to capture all of the strongest MFs generated by SWs.Clinical relevance- This provides a guide for the placement of MGG sensors for the capture of both normal and dysrhythmic gastric slow wave propagation.
Collapse
|
15
|
Du P, Liu JYH, Sukasem A, Qian A, Calder S, Rudd JA. Recent progress in electrophysiology and motility mapping of the gastrointestinal tract using multi-channel devices. J R Soc N Z 2020. [DOI: 10.1080/03036758.2020.1735455] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Peng Du
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
- Department of Engineering Science, The University of Auckland, Auckland, New Zealand
| | - Julia Y. H. Liu
- Faculty of Medicine, School of Biomedical Sciences, The Chinese University of Hong Kong, Hong Kong, People’s Republic of China
| | - Atchariya Sukasem
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Anna Qian
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Stefan Calder
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - John A. Rudd
- Faculty of Medicine, School of Biomedical Sciences, The Chinese University of Hong Kong, Hong Kong, People’s Republic of China
| |
Collapse
|
16
|
Calder S, O'Grady G, Cheng LK, Du P. A Simulated Anatomically Accurate Investigation Into the Effects of Biodiversity on Electrogastrography. IEEE Trans Biomed Eng 2020; 67:868-875. [DOI: 10.1109/tbme.2019.2922449] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
17
|
Kamat AA, Paskaranandavadivel N, Alighaleh S, Cheng LK, Angeli TR. Effects of Electrode Diameter and Contact Material on Signal Morphology of Gastric Bioelectrical Slow Wave Recordings. Ann Biomed Eng 2020; 48:1407-1418. [DOI: 10.1007/s10439-020-02457-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Accepted: 01/11/2020] [Indexed: 12/14/2022]
|
18
|
Chan CHA, Aghababaie Z, Paskaranandavadivel N, Cheng LK, Angeli TR. Methods for Visualization of Gastric Endoscopic Mapping Data From Three-Dimensional, Non-Uniform Electrode Arrays. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:2222-2225. [PMID: 31946342 DOI: 10.1109/embc.2019.8857158] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Methods were developed for visualizing three-dimensional endoscopic slow wave mapping data. Simulations representative of normal and abnormal slow wave propagation patterns were generated, allowing qualitative and quantitative evaluation of gridded and spherical interpolation algorithms. Three-dimensional isochronal maps provided a visual representation of slow wave propagation patterns, while mean absolute errors provided a quantitative metric for interpolation performance. Spherical thin plate spline interpolation provided an improvement over current gridded interpolation methods, with a 1.5 to 3.0 fold reduction of mean absolute errors (0.25-0.30 s to 0.08-0.15 s) over three classes of propagation patterns. Different electrode arrangements and densities were tested. A 128-electrode Fibonacci spiral arrangement was proposed as an efficient layout for capturing slow wave dynamics. These methods provide a new visualization technique suitable for endoscopic mapping, and provide a framework for testing and evaluating new interpolation techniques and device designs.
Collapse
|
19
|
Han H, Cheng LK, Angeli TR, Paskaranandavadivel N. Detection of Monophasic Slow-wave Activation Phase Using Wavelet Decomposition. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:7157-7160. [PMID: 31947485 DOI: 10.1109/embc.2019.8856736] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Gastric bio-electric slow-waves are in part responsible for generating motility. Extracellular recordings of the slow-wave activation phase have yielded significant physiological insight about its spatio-temporal characteristics. With the growth of multi-electrode data and long recording periods, there is a need for automated methods to detect the activation phase in a reliable and accurate manner. In this study, the Variable Threshold Wavelet (VTW) algorithm was developed, featuring wavelet decomposition, to compute the derivative to detect the slow-wave activation phase of monophasic signals. The performance of the VTW algorithm was compared against an existing Falling-Edge, Variable Threshold (FEVT) algorithm. Varying levels of synthetic noise representing ventilator and high-frequency noise were added to in vivo slow-wave recordings. Sensitivity, positive-predictive value, area under the curve (Aroc) metric and percentage improvement metric (PIM) of activation phase identification accuracy were calculated. Compared to the existing FEVT algorithm, the VTW algorithm achieved similar performance in identifying the activation phase of slow-waves with various levels of ventilator noise. In the presence of high-frequency noise, the VTW algorithm improved the Aroc of the existing FEVT algorithm by 11.1%. The VTW algorithm can now be applied to analyze normal and abnormal slow-wave recordings.
Collapse
|
20
|
Avci R, Paskaranandavadivel N, Calder S, Du P, Bradshaw LA, Cheng LK. Source localization for gastric electrical activity using simulated magnetogastrographic data. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:2336-2339. [PMID: 31946368 DOI: 10.1109/embc.2019.8857384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
In this study, the use of magnetic dipole (MDP) approximation to localize the underlying source of magnetogastrographic (MGG) data was investigated. An anatomically realistic torso and a stomach model were used to simulate slow wave (SW) activities and magnetic fields (MFs). SW activity in the stomach was simulated using a grid-based finite element method. The SW activity at each time sample was represented by the dipoles generated for each element and MFs were computed from these dipoles including secondary sources in the torso. Gaussian noise was added to the MFs to represent experimental signal noise. MDP fitting was executed on the time samples of selected 2-second time frames, and goodness of fit (GOF) and the distance from the fitted MDP to the center of gravity (COG) of active dipoles were computed. Then, for each time frame, the spatial changes of COG and MDP positions in x-, y-, and z-directions and correlation scores were computed. Our results showed that MDP fitting was capable of identifying propagation patterns with mean correlation scores of 0.63 ± 0.30, 0.71 ± 0.19, and 0.81 ± 0.24 in x-, y-, and z-directions, respectively. The mean distance from COGs to the identified MDPs was 49±4 mm. The results were similar under the noise conditions as well. Our results suggest that source localization using MDP approximation can be useful to identify the propagation characteristics of SWs using MGG data.
Collapse
|
21
|
Farajidavar A. Bioelectronics for mapping gut activity. Brain Res 2019; 1693:169-173. [PMID: 29903619 DOI: 10.1016/j.brainres.2018.03.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2017] [Revised: 03/01/2018] [Accepted: 03/02/2018] [Indexed: 12/18/2022]
Abstract
Gastric peristalsis is initiated and coordinated by an underlying bioelectrical activity, termed slow waves. High-resolution (HR) mapping of the slow waves has become a fundamental tool for accurately defining electrophysiological properties in gastroenterology, including dysrhythmias in gastric disorders such as gastroparesis and functional dyspepsia. Currently, HR mapping is achieved via acquisition of slow waves taken directly from the serosa of fasted subjects undergoing invasive abdominal surgery. Recently, a minimally invasive retractable catheter and electrode has been developed for HR mapping that can only be used in short-term studies in subjects undergoing laparoscopy. Noninvasive mapping has also emerged from multichannel cutaneous electrogastrography; however, it lacks sufficient resolution and is prone to artifacts. Bioelectronics that can map slow waves in conscious subjects, postprandially and long-term, are in high demand. Due to the low signal-to-noise ratio of cutaneous electrogastrography, electrodes for HR mapping of gut activity have to acquire slow waves directly from the gut; hence, development of novel device implantation methods has inevitably accompanied development of the devices themselves. Initial efforts that have paved the way toward achieving these goals have included development of miniature wireless systems with a limited number of acquisition channels using commercially available off-the-shelf electronic components, flexible HR electrodes, and endoscopic methods for minimally invasive device implantation. To further increase the spatial resolution of HR mapping, and to minimize the size and power consumption of the implant for long-term studies, application-specific integrated circuitry, wireless power transfer, and stretchable electronics technologies have had to be integrated into a single system.
Collapse
Affiliation(s)
- Aydin Farajidavar
- Department of Electrical and Computer Engineering, New York Institute of Technology, Room 226B, Schure Hall, Northern Blvd, Old Westbury, NY 11568-8000, USA.
| |
Collapse
|
22
|
Du P, Grady GO, Paskaranandavadivel N, Tang SJ, Abell T, Cheng LK. High-resolution Mapping of Hyperglycemia-induced Gastric Slow Wave Dysrhythmias. J Neurogastroenterol Motil 2019; 25:276-285. [PMID: 30870879 PMCID: PMC6474709 DOI: 10.5056/jnm18192] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2018] [Revised: 12/27/2018] [Accepted: 01/16/2019] [Indexed: 12/11/2022] Open
Abstract
Background/Aims It is now recognised that gastric dysrhythmias are best characterised by their spatial propagation pattern. Hyperglycemia is an important cause of gastric slow wave dysrhythmia, however, the spatiotemporal patterns of dysrhythmias in this context have not been investigated. This study aims to investigate the relationship between hyperglycemia and the patterns of dysrhythmias by employing high-resolution (multi-electrode) mapping simultaneously at the anterior and posterior gastric serosa. Methods High-resolution mapping (8 × 16 electrodes per serosal) was performed in 4 anesthetized hounds. Baseline recordings (21 ± 8 minutes) were followed by intravenous injection of glucagon (0.5 mg per dose) and further recordings (59 ± 15 minutes). Blood glucose levels were monitored manually using a glucose sensing kit at regular 5-minute intervals. Slow wave activation maps, amplitudes, velocity, anisotropic ratio, and frequency were calculated. Differences were compared between baseline and post glucagon injection. Results Baseline slow waves propagated symmetrically and antegrade. The blood glucose levels were increased by an average of 112% compared to the baseline by the end of the recordings. All subjects demonstrated elevated incidence of slow wave dysrhythmias following injection compared to the baseline (48 ± 23% vs 6 ± 4%, P < 0.05). Dysrhythmias arose simultaneously or independently on anterior and posterior serosa. Spatial dysrhythmias occurred before and persisted after the onset and disappearance of temporal dysrhythmias. Conclusions Infusion of glucagon induced gastric slow wave dysrhythmias, which occurred across a heterogeneous range of patterns and frequencies. The spatial dysrhythmias of gastric slow waves were shown to be more prevalent and persisted over a longer period of time compared to the temporal dysrhythmias.
Collapse
Affiliation(s)
- Peng Du
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Gregory O' Grady
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.,Department of Surgery, University of Auckland, Auckland, New Zealand
| | | | | | | | - Leo K Cheng
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.,Department of Surgery, Vanderbilt University, Nashville, TN, USA
| |
Collapse
|
23
|
Zhang H, Yu H, Walcott GP, Paskaranandavadivel N, Cheng LK, O’Grady G, Rogers JM. High-resolution optical mapping of gastric slow wave propagation. Neurogastroenterol Motil 2019; 31:e13449. [PMID: 30129082 PMCID: PMC6724537 DOI: 10.1111/nmo.13449] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Revised: 06/20/2018] [Accepted: 07/18/2018] [Indexed: 01/03/2023]
Abstract
BACKGROUND Improved understanding of the details of gastric slow wave propagation could potentially inform new diagnosis and treatment options for stomach motility disorders. Optical mapping has been used extensively in cardiac electrophysiology. Although optical mapping has a number of advantages relative to electrical mapping, optical signals are highly sensitive to motion artifact. We recently introduced a novel cardiac optical mapping method that corrects motion artifact and enables optical mapping to be performed in beating hearts. Here, we reengineer the method as an experimental tool to map gastric slow waves. METHODS The method was developed and tested in 12 domestic farm pigs. Stomachs were exposed by laparotomy and stained with the voltage-sensitive fluorescence dye di-4-ANEPPS through a catheter placed in the gastroepiploic artery. Fiducial markers for motion tracking were attached to the serosa. The dye was excited by 450 or 505 nm light on alternate frames of an imaging camera running at 300 Hz. Emitted fluorescence was imaged between 607 and 695 nm. The optical slow wave signal was reconstructed using a combination of motion tracking and excitation ratiometry to suppress motion artifact. Optical slow wave signals were compared with simultaneously recorded bipolar electrograms and suction electrode signals, which approximate membrane potential. KEY RESULTS The morphology of optical slow waves was consistent with previously published microelectrode recordings and simultaneously recorded suction electrode signals. The timing of the optical slow wave signals was consistent with the bipolar electrograms. CONCLUSIONS AND INFERENCES Optical mapping of slow wave propagation in the stomach is feasible.
Collapse
Affiliation(s)
- Hanyu Zhang
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, Alabama, United States
| | - Han Yu
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, Alabama, United States
| | - Gregory P. Walcott
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, Alabama, United States,Division of Cardiovascular Disease, Department of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, United States
| | - Niranchan Paskaranandavadivel
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand,Department of Surgery, The University of Auckland, Auckland, New Zealand
| | - Leo K Cheng
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand,Department of Surgery, Vanderbilt University, Nashville, Tennessee, United States
| | - Gregory O’Grady
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand,Department of Surgery, The University of Auckland, Auckland, New Zealand
| | - Jack M. Rogers
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, Alabama, United States,Corresponding author: 1670 University Blvd, Volker Hall B140, Birmingham, AL, 35294, USA, (205) 975-2102,
| |
Collapse
|
24
|
O'Grady G, Angeli TR, Paskaranandavadivel N, Erickson JC, Wells CI, Gharibans AA, Cheng LK, Du P. Methods for High-Resolution Electrical Mapping in the Gastrointestinal Tract. IEEE Rev Biomed Eng 2018; 12:287-302. [PMID: 30176605 DOI: 10.1109/rbme.2018.2867555] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Over the last two decades, high-resolution (HR) mapping has emerged as a powerful technique to study normal and abnormal bioelectrical events in the gastrointestinal (GI) tract. This technique, adapted from cardiology, involves the use of dense arrays of electrodes to track bioelectrical sequences in fine spatiotemporal detail. HR mapping has now been applied in many significant GI experimental studies informing and clarifying both normal physiology and arrhythmic behaviors in disease states. This review provides a comprehensive and critical analysis of current methodologies for HR electrical mapping in the GI tract, including extracellular measurement principles, electrode design and mapping devices, signal processing and visualization techniques, and translational research strategies. The scope of the review encompasses the broad application of GI HR methods from in vitro tissue studies to in vivo experimental studies, including in humans. Controversies and future directions for GI mapping methodologies are addressed, including emerging opportunities to better inform diagnostics and care in patients with functional gut disorders of diverse etiologies.
Collapse
|
25
|
Angeli TR, O'Grady G, Vather R, Bissett IP, Cheng LK. Intra-operative high-resolution mapping of slow wave propagation in the human jejunum: Feasibility and initial results. Neurogastroenterol Motil 2018; 30:e13310. [PMID: 29493080 DOI: 10.1111/nmo.13310] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2017] [Accepted: 01/11/2018] [Indexed: 02/08/2023]
Abstract
BACKGROUND Bioelectrical slow waves are a coordinating mechanism of small intestine motility, but extracellular human studies have been restricted to a limited number of sparse electrode recordings. High-resolution (HR) mapping has offered substantial insights into spatiotemporal intestinal slow wave dynamics, but has been limited to animal studies to date. This study aimed to translate intra-operative HR mapping to define pacemaking and conduction profiles in the human small intestine. METHODS Immediately following laparotomy, flexible-printed-circuit arrays were applied around the serosa of the proximal jejunum (128-256 electrodes; 4-5.2 mm spacing; 28-59 cm2 ). Slow wave propagation patterns were mapped, and frequencies, amplitudes, downstroke widths, and velocities were calculated. Pacemaking and propagation patterns were defined. KEY RESULTS Analysis comprised nine patients with mean recording duration of 7.6 ± 2.8 minutes. Slow waves occurred at a frequency of 9.8 ± 0.4 cpm, amplitude 0.3 ± 0.04 mV, downstroke width 0.5 ± 0.1 seconds, and with faster circumferential velocity than longitudinal (10.1 ± 0.8 vs 9.0 ± 0.7 mm/s; P = .001). Focal pacemakers were identified and mapped (n = 4; mean frequency 9.9 ± 0.2 cpm). Disordered slow wave propagation was observed, including wavefront collisions, conduction blocks, and breakout and entrainment of pacemakers. CONCLUSIONS & INFERENCES This study introduces HR mapping of human intestinal slow waves, and provides first descriptions of intestinal pacemaker sites and velocity anisotropy. Future translation to other intestinal regions, disease states, and postsurgical dysmotility holds potential for improving the basic and clinical understanding of small intestine pathophysiology.
Collapse
Affiliation(s)
- T R Angeli
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - G O'Grady
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.,Department of Surgery, University of Auckland, Auckland, New Zealand
| | - R Vather
- Department of Surgery, University of Auckland, Auckland, New Zealand
| | - I P Bissett
- Department of Surgery, University of Auckland, Auckland, New Zealand
| | - L K Cheng
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.,Department of Surgery, Vanderbilt University, Nashville, TN, USA
| |
Collapse
|
26
|
Patterns of Abnormal Gastric Pacemaking After Sleeve Gastrectomy Defined by Laparoscopic High-Resolution Electrical Mapping. Obes Surg 2018; 27:1929-1937. [PMID: 28213666 DOI: 10.1007/s11695-017-2597-6] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Laparoscopic sleeve gastrectomy (LSG) is increasingly being applied to treat obesity. LSG includes excision of the normal gastric pacemaker, which could induce electrical dysrhythmias impacting on post-operative symptoms and recovery, but these implications have not been adequately investigated. This study aimed to define the effects of LSG on gastric slow-wave pacemaking using laparoscopic high-resolution (HR) electrical mapping. METHODS Laparoscopic HR mapping was performed before and after LSG using flexible printed circuit arrays (64-96 electrodes; 8-12 cm2; n = 8 patients) deployed through a 12 mm trocar and positioned on the gastric serosa. An additional patient with chronic reflux, nausea, and dysmotility 6 months after LSG also underwent gastric mapping while undergoing conversion to gastric bypass. Slow-wave activity was quantified by propagation pattern, frequency, velocity, and amplitude. RESULTS Baseline activity showed exclusively normal propagation. Acutely after LSG, all patients developed either a distal unifocal ectopic pacemaker with retrograde propagation (50%) or bioelectrical quiescence (50%). Propagation velocity was abnormally rapid after LSG (12.5 ± 0.8 vs baseline 3.8 ± 0.8 mm s-1; p = 0.01), whereas frequency and amplitude were unchanged (2.7 ± 0.3 vs 2.8 ± 0.3 cpm, p = 0.7; 1.7 ± 0.2 vs 1.6 ± 0.6 mV, p = 0.7). In the patient with chronic dysmotility after LSG, mapping also revealed a stable antral ectopic pacemaker with retrograde rapid propagation (12.6 ± 4.8 mm s-1). CONCLUSION Resection of the gastric pacemaker during LSG acutely resulted in aberrant distal ectopic pacemaking or bioelectrical quiescence. Ectopic pacemaking can persist long after LSG, inducing chronic dysmotility. The clinical and therapeutic significance of these findings now require further investigation.
Collapse
|
27
|
Du P, Calder S, Angeli TR, Sathar S, Paskaranandavadivel N, O'Grady G, Cheng LK. Progress in Mathematical Modeling of Gastrointestinal Slow Wave Abnormalities. Front Physiol 2018; 8:1136. [PMID: 29379448 PMCID: PMC5775268 DOI: 10.3389/fphys.2017.01136] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2017] [Accepted: 12/22/2017] [Indexed: 12/19/2022] Open
Abstract
Gastrointestinal (GI) motility is regulated in part by electrophysiological events called slow waves, which are generated by the interstitial cells of Cajal (ICC). Slow waves propagate by a process of "entrainment," which occurs over a decreasing gradient of intrinsic frequencies in the antegrade direction across much of the GI tract. Abnormal initiation and conduction of slow waves have been demonstrated in, and linked to, a number of GI motility disorders. A range of mathematical models have been developed to study abnormal slow waves and applied to propose novel methods for non-invasive detection and therapy. This review provides a general outline of GI slow wave abnormalities and their recent classification using multi-electrode (high-resolution) mapping methods, with a particular emphasis on the spatial patterns of these abnormal activities. The recently-developed mathematical models are introduced in order of their biophysical scale from cellular to whole-organ levels. The modeling techniques, main findings from the simulations, and potential future directions arising from notable studies are discussed.
Collapse
Affiliation(s)
- Peng Du
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Stefan Calder
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Timothy R. Angeli
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Shameer Sathar
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | | | - Gregory O'Grady
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
- Department of Surgery, University of Auckland, Auckland, New Zealand
| | - Leo K. Cheng
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
- Department of Surgery, Vanderbilt University, Nashville, TN, United States
| |
Collapse
|
28
|
Wang THH, Du P, Angeli TR, Paskaranandavadivel N, Erickson JC, Abell TL, Cheng LK, O'Grady G. Relationships between gastric slow wave frequency, velocity, and extracellular amplitude studied by a joint experimental-theoretical approach. Neurogastroenterol Motil 2018; 30. [PMID: 28695661 DOI: 10.1111/nmo.13152] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2017] [Accepted: 06/08/2017] [Indexed: 02/08/2023]
Abstract
BACKGROUND Gastric slow wave dysrhythmias are accompanied by deviations in frequency, velocity, and extracellular amplitude, but the inherent association between these parameters in normal activity still requires clarification. This study quantified these associations using a joint experimental-theoretical approach. METHODS Gastric pacing was conducted in pigs with simultaneous high-resolution slow wave mapping (32-256 electrodes; 4-7.6 mm spacing). Relationships between period, velocity, and amplitude were quantified and correlated for each wavefront. Human data from two existing mapping control cohorts were analyzed to extract and correlate these same parameters. A validated biophysically based ICC model was also applied in silico to quantify velocity-period relationships during entrainment simulations and velocity-amplitude relationships from membrane potential equations. KEY RESULTS Porcine pacing studies identified positive correlations for velocity-period (0.13 mm s-1 per 1 s, r2 =.63, P<.001) and amplitude-velocity (74 μV per 1 mm s-1 , r2 =.21, P=.002). In humans, positive correlations were also quantified for velocity-period (corpus: 0.11 mm s-1 per 1 s, r2 =.16, P<.001; antrum: 0.23 mm s-1 per 1 s, r2 =.55; P<.001), and amplitude-velocity (94 μV per 1 mm s-1 , r2 =.56; P<.001). Entrainment simulations matched the experimental velocity-period relationships and demonstrated dependence on the slow wave recovery phase. Simulated membrane potential relationships were close to these experimental results (100 μV per 1 mm s-1 ). CONCLUSIONS AND INFERENCES These data quantify the relationships between slow wave frequency, velocity, and extracellular amplitude. The results from both human and porcine studies were in keeping with biophysical models, demonstrating concordance with ICC biophysics. These relationships are important in the regulation of gastric motility and will help to guide interpretations of dysrhythmias.
Collapse
Affiliation(s)
- T H-H Wang
- Department of Surgery, University of Auckland, Auckland, New Zealand
| | - P Du
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - T R Angeli
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - N Paskaranandavadivel
- Department of Surgery, University of Auckland, Auckland, New Zealand.,Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - J C Erickson
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.,Department of Physics-Engineering, Washington & Lee University, Lexington, VA, USA
| | - T L Abell
- Division of Gastroenterology, University of Louisville, Louisville, KY, USA
| | - L K Cheng
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.,Department of Surgery, Vanderbilt University, Nashville, TN, USA
| | - G O'Grady
- Department of Surgery, University of Auckland, Auckland, New Zealand.,Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| |
Collapse
|
29
|
Qian A, Means S, Cheng LK, Sneyd J. A mathematical model of the effects of anoctamin-1 loss on intestinal slow wave entrainment. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2017:2688-2691. [PMID: 29060453 DOI: 10.1109/embc.2017.8037411] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The interstitial cells of Cajal (ICC) generate electrophysiological events called slow waves that regulate the motility of the gastrointestinal (GI) tract. Recent studies have demonstrated that the Ca2+-activated Cl- -channel, encoded by the anoctamin1 (Ano1) protein, has a major role in regulating intestinal slow waves and motility. The main aim of this study was to develop a multi-scale mathematical model capable of simulating both normal slow wave entrainment and the effects of Ano1 knockout (KO) on the normal activity. A biophysically-based cell model was adapted to simulate the effects of Ano1 KO at the cellular level. A 10mm one-dimensional (1D) model was then developed to simulate entrained intestinal slow wave propagation. Cellular KO at levels of 100% and 20% were applied to a varying-sized middle region of the 1D model. The main finding was that the level of loss of entrainment increased as both cellular and spatial Ano1 KO levels increased, mostly manifesting as ectopic activation. In the future, this model will be extended and used in combination with Ca2+ -imaging data to quantitatively investigate the effects of Ano1 loss in ICC.
Collapse
|
30
|
Du P, O'Grady G, Cheng LK. A theoretical analysis of anatomical and functional intestinal slow wave re-entry. J Theor Biol 2017; 425:72-79. [DOI: 10.1016/j.jtbi.2017.04.021] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Revised: 04/19/2017] [Accepted: 04/21/2017] [Indexed: 12/26/2022]
|
31
|
Morishita H, Iwata N, Takai C, Mochizuki N, Kaji N, Hori M, Kajioka S, Nakayama S. Micro-Coordination of Pacemaker Potentials in the Intestine of the Mouse. Gastroenterology 2017; 152:1831-1833.e4. [PMID: 28433349 DOI: 10.1053/j.gastro.2017.04.016] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2016] [Revised: 02/22/2017] [Accepted: 04/05/2017] [Indexed: 12/02/2022]
Affiliation(s)
- Hirotaka Morishita
- Department of Cell Physiology, Graduate School of Medicine, Nagoya University, Nagoya, Japan
| | - Naoko Iwata
- Department of Cell Physiology, Graduate School of Medicine, Nagoya University, Nagoya, Japan
| | - Chiho Takai
- Department of Cell Physiology, Graduate School of Medicine, Nagoya University, Nagoya, Japan
| | - Naoto Mochizuki
- Department of Cell Physiology, Graduate School of Medicine, Nagoya University, Nagoya, Japan
| | - Noriyuki Kaji
- Department of Veterinary Pharmacology, Graduate School of Agriculture and Life Sciences, The University of Tokyo, Tokyo, Japan
| | - Masatoshi Hori
- Department of Veterinary Pharmacology, Graduate School of Agriculture and Life Sciences, The University of Tokyo, Tokyo, Japan
| | - Shunichi Kajioka
- Department of Applied Urology and Molecular Medicine, Graduate School of Medicine, Kyushu University, Kyushu, Japan
| | - Shinsuke Nakayama
- Department of Cell Physiology, Graduate School of Medicine, Nagoya University, Nagoya, Japan.
| |
Collapse
|
32
|
Angeli TR, Du P, Paskaranandavadivel N, Sathar S, Hall A, Asirvatham SJ, Farrugia G, Windsor JA, Cheng LK, O'Grady G. High-resolution electrical mapping of porcine gastric slow-wave propagation from the mucosal surface. Neurogastroenterol Motil 2017; 29:10.1111/nmo.13010. [PMID: 28035728 PMCID: PMC5393964 DOI: 10.1111/nmo.13010] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/06/2016] [Accepted: 11/19/2016] [Indexed: 12/12/2022]
Abstract
BACKGROUND Gastric motility is coordinated by bioelectrical slow waves, and gastric dysrhythmias are reported in motility disorders. High-resolution (HR) mapping has advanced the accurate assessment of gastric dysrhythmias, offering promise as a diagnostic technique. However, HR mapping has been restricted to invasive surgical serosal access. This study investigates the feasibility of HR mapping from the gastric mucosal surface. METHODS Experiments were conducted in vivo in 14 weaner pigs. Reference serosal recordings were performed with flexible-printed-circuit (FPC) arrays (128-192 electrodes). Mucosal recordings were performed by two methods: (i) FPC array aligned directly opposite the serosal array, and (ii) cardiac mapping catheter modified for gastric mucosal recordings. Slow-wave propagation and morphology characteristics were quantified and compared between simultaneous serosal and mucosal recordings. KEY RESULTS Slow-wave activity was consistently recorded from the mucosal surface from both electrode arrays. Mucosally recorded slow-wave propagation was consistent with reference serosal activation pattern, frequency (P≥.3), and velocity (P≥.4). However, mucosally recorded slow-wave morphology exhibited reduced amplitude (65-72% reduced, P<.001) and wider downstroke width (18-31% wider, P≤.02), compared to serosal data. Dysrhythmias were successfully mapped and classified from the mucosal surface, accorded with serosal data, and were consistent with known dysrhythmic mechanisms in the porcine model. CONCLUSIONS & INFERENCES High-resolution gastric electrical mapping was achieved from the mucosal surface, and demonstrated consistent propagation characteristics with serosal data. However, mucosal signal morphology was attenuated, demonstrating necessity for optimized electrode designs and analytical algorithms. This study demonstrates feasibility of endoscopic HR mapping, providing a foundation for advancement of minimally invasive spatiotemporal gastric mapping as a clinical and scientific tool.
Collapse
Affiliation(s)
- Timothy R. Angeli
- Auckland Bioengineering Institute, University of Auckland, New Zealand
| | - Peng Du
- Auckland Bioengineering Institute, University of Auckland, New Zealand
| | | | - Shameer Sathar
- Auckland Bioengineering Institute, University of Auckland, New Zealand
| | - Andrew Hall
- Department of Surgery, University of Auckland, New Zealand
| | | | - Gianrico Farrugia
- Department of Gastroenterology and Hepatology, Mayo Clinic, Rochester, MN, USA
| | | | - Leo K. Cheng
- Auckland Bioengineering Institute, University of Auckland, New Zealand., Department of Surgery, Vanderbilt University, Nashville, TN, USA
| | - Gregory O'Grady
- Auckland Bioengineering Institute, University of Auckland, New Zealand., Department of Surgery, University of Auckland, New Zealand
| |
Collapse
|
33
|
Calder S, O'Grady G, Cheng LK. A Theoretical Analysis of Electrogastrography (EGG) Signatures Associated With Gastric Dysrhythmias. IEEE Trans Biomed Eng 2016; 64:1592-1601. [PMID: 28113227 DOI: 10.1109/tbme.2016.2614277] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Routine screening and accurate diagnosis of chronic gastrointestinal motility disorders represent a significant problem in current clinical practice. The electrogastrography (EGG) provides a noninvasive option for assessing gastric slow waves, as a means of diagnosing gastric dysrhythmias, but its uptake in motility practice has been limited partly due to an incomplete sensitivity and specificity. This paper presents the development of a human whole-organ gastric model to enable virtual (in silico) testing of gastric electrophysiological dispersion in order to improve the diagnostic accuracy of EGG. The model was developed to simulate normal gastric slow wave conduction as well as three types of dysrhythmias identified in recent high-resolution gastric mapping studies: conduction block, re-entry, and ectopic pacemaking. The stomach simulations were then applied in a torso model to identify predicted EGG signatures of normal and dysrhythmic slow wave profiles. The resulting EGG data were compared using percentage differences and correlation coefficients. Virtual EGG channels that demonstrated a percentage difference over 100% and a correlation coefficient less than ±0.2 (threshold relaxed to ±0.5 for the ectopic pacemaker case) were further investigated for their specific distinguishing features. In particular, anatomical locations from the epigastric region and specific channel configurations were identified that could be used to clinically diagnose the three classes of human gastric dysrhythmia. These locations and channels predicted by simulations present a promising methodology for improving the clinical reliability and applications of EGG.
Collapse
|
34
|
Du P, O'Grady G, Paskaranandavadivel N, Tang SJ, Abell T, Cheng LK. Simultaneous anterior and posterior serosal mapping of gastric slow-wave dysrhythmias induced by vasopressin. Exp Physiol 2016; 101:1206-1217. [PMID: 27265885 PMCID: PMC5140776 DOI: 10.1113/ep085697] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2015] [Accepted: 05/31/2016] [Indexed: 12/23/2022]
Abstract
NEW FINDINGS What is the central question of this study? This study aimed to provide the first comparison of simultaneous high-resolution mapping of anterior and posterior gastric serosa over sustained periods. What is the main finding and its importance? Episodes of spontaneous gastric slow-wave dysrhythmias increased significantly following intravenous infusion of vasopressin compared with the baseline state. A number of persistent dysrhythmias were defined, including ectopic activation, conduction block, rotor, retrograde and collision/merger of wavefronts. Slow-wave dysrhythmias could occur either simultaneously or independently on the anterior and posterior gastric serosa, and interacted depending on activation-repolarization and frequency dynamics. High-resolution mapping enables mechanistic insights into gastric slow-wave dysrhythmias and is now achieving clinical translation. However, previous studies have focused mainly on dysrhythmias occurring on the anterior gastric wall. The present study simultaneously mapped the anterior and posterior gastric serosa during episodes of dysrhythmias induced by vasopressin to aid understanding of dysrhythmia initiation, maintenance and termination. High-resolution mapping (8 × 16 electrodes on each serosa; 20-74 cm2 ) was performed in anaesthetized dogs. Baseline recordings (21 ± 8 min) were followed by intravenous infusion of vasopressin (0.1-0.5 IU ml-1 at 60-190 ml h-1 ) and further recordings (22 ± 13 min). Slow-wave activation maps, amplitudes, velocity, interval and frequency were calculated, and differences compared between baseline and postinfusion. All dogs demonstrated an increased prevalence of dysrhythmic events following infusion of vasopressin (17 versus 51%). Both amplitude and velocity demonstrated significant differences (baseline versus postinfusion: 3.6 versus 2.2 mV; 7.7 versus 6.5 mm s-1 ; P < 0.05 for both). Dysrhythmias occurred simultaneously or independently on the anterior and posterior serosa, and then interacted according to frequency dynamics. A number of persistent dysrhythmias were compared, including the following: ectopic activation (n = 2 animals), conduction block (n = 1), rotor (n = 2), retrograde (n = 3) and collision/merger of wavefronts (n = 2). We conclude that infusion of vasopressin induces gastric dysrhythmias, which occur across a heterogeneous range of frequencies and patterns. The results demonstrate that different classes of gastric dysrhythmias may arise simultaneously or independently in one or both surfaces of the serosa, then interact according to their relative frequencies. These results will help to inform interpretation of clinical dysrhythmia.
Collapse
Affiliation(s)
- Peng Du
- Auckland Bioengineering Institute, University of Auckland, New Zealand
| | - Greg O'Grady
- Auckland Bioengineering Institute, University of Auckland, New Zealand
- Department of Surgery, University of Auckland, New Zealand
| | | | | | | | - Leo K Cheng
- Auckland Bioengineering Institute, University of Auckland, New Zealand
- Department of Surgery, Vanderbilt University, Nashville, TN, USA
| |
Collapse
|
35
|
Tse G, Lai ETH, Lee APW, Yan BP, Wong SH. Electrophysiological Mechanisms of Gastrointestinal Arrhythmogenesis: Lessons from the Heart. Front Physiol 2016; 7:230. [PMID: 27378939 PMCID: PMC4906021 DOI: 10.3389/fphys.2016.00230] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2016] [Accepted: 05/30/2016] [Indexed: 01/09/2023] Open
Abstract
Disruptions in the orderly activation and recovery of electrical excitation traveling through the heart and the gastrointestinal (GI) tract can lead to arrhythmogenesis. For example, cardiac arrhythmias predispose to thromboembolic events resulting in cerebrovascular accidents and myocardial infarction, and to sudden cardiac death. By contrast, arrhythmias in the GI tract are usually not life-threatening and much less well characterized. However, they have been implicated in the pathogenesis of a number of GI motility disorders, including gastroparesis, dyspepsia, irritable bowel syndrome, mesenteric ischaemia, Hirschsprung disease, slow transit constipation, all of which are associated with significant morbidity. Both cardiac and gastrointestinal arrhythmias can broadly be divided into non-reentrant and reentrant activity. The aim of this paper is to compare and contrast the mechanisms underlying arrhythmogenesis in both systems to provide insight into the pathogenesis of GI motility disorders and potential molecular targets for future therapy.
Collapse
Affiliation(s)
- Gary Tse
- Li Ka Shing Faculty of Medicine, School of Biomedical Sciences, The University of Hong KongHong Kong, China
- Department of Medicine and Therapeutics, The Chinese University of Hong KongHong Kong, China
| | - Eric T. H. Lai
- Li Ka Shing Faculty of Medicine, School of Biomedical Sciences, The University of Hong KongHong Kong, China
| | - Alex P. W. Lee
- Department of Medicine and Therapeutics, The Chinese University of Hong KongHong Kong, China
| | - Bryan P. Yan
- Department of Medicine and Therapeutics, The Chinese University of Hong KongHong Kong, China
| | - Sunny H. Wong
- Department of Medicine and Therapeutics, Institute of Digestive Disease, Li Ka Shing Institute of Health Sciences, The Chinese University of Hong KongHong Kong, China
| |
Collapse
|
36
|
A novel retractable laparoscopic device for mapping gastrointestinal slow wave propagation patterns. Surg Endosc 2016; 31:477-486. [PMID: 27129554 DOI: 10.1007/s00464-016-4936-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2015] [Accepted: 04/09/2016] [Indexed: 01/28/2023]
Abstract
BACKGROUND Gastric slow waves regulate peristalsis, and gastric dysrhythmias have been implicated in functional motility disorders. To accurately define slow wave patterns, it is currently necessary to collect high-resolution serosal recordings during open surgery. We therefore developed a novel gastric slow wave mapping device for use during laparoscopic procedures. METHODS The device consists of a retractable catheter constructed of a flexible nitinol core coated with Pebax. Once deployed through a 5-mm laparoscopic port, the spiral head is revealed with 32 electrodes at 5 mm intervals. Recordings were validated against a reference electrode array in pigs and tested in a human patient. RESULTS Recordings from the device and a reference array in pigs were identical in frequency (2.6 cycles per minute; p = 0.91), and activation patterns and velocities were consistent (8.9 ± 0.2 vs 8.7 ± 0.1 mm s-1; p = 0.2). Device and reference amplitudes were comparable (1.3 ± 0.1 vs 1.4 ± 0.1 mV; p = 0.4), though the device signal-to-noise ratio was higher (17.5 ± 0.6 vs 12.8 ± 0.6 dB; P < 0.0001). In the human patient, corpus slow waves were recorded and mapped (frequency 2.7 ± 0.03 cycles per minute, amplitude 0.8 ± 0.4 mV, velocity 2.3 ± 0.9 mm s-1). CONCLUSION In conclusion, the novel laparoscopic device achieves high-quality serosal slow wave recordings. It can be used for laparoscopic diagnostic studies to document slow wave patterns in patients with gastric motility disorders.
Collapse
|
37
|
Paskaranandavadivel N, OGrady G, Cheng LK. Time-Delay Mapping of High-Resolution Gastric Slow-Wave Activity. IEEE Trans Biomed Eng 2016; 64:166-172. [PMID: 27071158 DOI: 10.1109/tbme.2016.2548940] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
GOAL Analytic monitoring of electrophysiological data has become an essential component of efficient and accurate clinical care. In the gastrointestinal (GI) field, recent advances in high-resolution (HR) mapping are now providing critical information about spatiotemporal profiles of slow-wave activity in normal and disease (dysrhythmic) states. The current approach to analyze GI HR electrophysiology data involves the identification of individual slow-wave events in the electrode array, followed by tracking and clustering of events to create a spatiotemporal map. This method is labor and computationally intensive and is not well suited for real-time clinical use or chronic monitoring. METHODS In this study, an automated novel technique to assess propagation patterns was developed. The method utilized time delays of the slow-wave signals which was computed through cross correlations to calculate velocity. Validation was performed with both synthetic and human and porcine experimental data. RESULTS The slow-wave profiles computed via the time-delay method compared closely with those computed using the traditional method (speed difference: 7.2% ± 2.6%; amplitude difference: 8.6% ± 3.5%, and negligible angle difference). CONCLUSION This novel method provides rapid and intuitive analysis and visualization of slow-wave activity. SIGNIFICANCE This techniques will find major applications in the clinical translation of acute and chronic HR electrical mapping for motility disorders, and act as a screening tool for detailed detection and tracking of individual propagating wavefronts, without the need for comprehensive standard event-detection analysis.
Collapse
|
38
|
Erickson JC, Putney J, Hilbert D, Paskaranandavadivel N, Cheng LK, O'Grady G, Angeli TR. Iterative Covariance-Based Removal of Time-Synchronous Artifacts: Application to Gastrointestinal Electrical Recordings. IEEE Trans Biomed Eng 2016; 63:2262-2272. [PMID: 26829772 DOI: 10.1109/tbme.2016.2521764] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
OBJECTIVE The aim of this study was to develop, validate, and apply a fully automated method for reducing large temporally synchronous artifacts present in electrical recordings made from the gastrointestinal (GI) serosa, which are problematic for properly assessing slow wave dynamics. Such artifacts routinely arise in experimental and clinical settings from motion, switching behavior of medical instruments, or electrode array manipulation. METHODS A novel iterative Covariance-Based Reduction of Artifacts (COBRA) algorithm sequentially reduced artifact waveforms using an updating across-channel median as a noise template, scaled and subtracted from each channel based on their covariance. RESULTS Application of COBRA substantially increased the signal-to-artifact ratio (12.8 ± 2.5 dB), while minimally attenuating the energy of the underlying source signal by 7.9% on average ( -11.1 ± 3.9 dB). CONCLUSION COBRA was shown to be highly effective for aiding recovery and accurate marking of slow wave events (sensitivity = 0.90 ± 0.04; positive-predictive value = 0.74 ± 0.08) from large segments of in vivo porcine GI electrical mapping data that would otherwise be lost due to a broad range of contaminating artifact waveforms. SIGNIFICANCE Strongly reducing artifacts with COBRA ultimately allowed for rapid production of accurate isochronal activation maps detailing the dynamics of slow wave propagation in the porcine intestine. Such mapping studies can help characterize differences between normal and dysrhythmic events, which have been associated with GI abnormalities, such as intestinal ischemia and gastroparesis. The COBRA method may be generally applicable for removing temporally synchronous artifacts in other biosignal processing domains.
Collapse
Affiliation(s)
- Jonathan C Erickson
- Department of Physics and Engineering, Washington and Lee University, Lexington, VA, USA
| | - Joy Putney
- Department of Physics and Engineering, Washington and Lee University
| | - Douglas Hilbert
- Departments of Mathematics and Biochemistry, Washington and Lee University
| | | | | | | | | |
Collapse
|
39
|
Paskaranandavadivel N, Du P, Erickson J, O'Grady G, Cheng LK. Extending the automated gastrointestinal analysis pipeline: Removal of invalid slow wave marks in gastric serosal recordings. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:1938-41. [PMID: 26736663 DOI: 10.1109/embc.2015.7318763] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Gastric contractions are governed by a bioelectrical event known as slow waves. High-resolution electrical mapping has recently been applied to study complex gastric slow wave spatiotemporal propagations in detail. As these methods are translated to clinical and experimental applications, it is evident that efficient and automated methods are a necessity for analysis. Despite automated methods to detect slow wave events, manual review and correction remains necessary due to the presence of experimental noise in the recordings. Manual deletion of invalid slow wave events is time consuming and inefficient. We have therefore developed an algorithm to eliminate invalid markers of slow waves, via the use of frequency and morphological analysis. The techniques were validated with experimental data using serosal gastric slow wave recordings from animals and humans with a sensitivity of 90% and specificity of 85%. It is anticipated these methods will facilitate analyzing high-resolution slow wave mapping data and accelerate clinical translation of electrical mapping to clinical and diagnostic gastroentrology.
Collapse
|
40
|
Abstract
BACKGROUND Ethanol ingestion causes a variety of gastrointestinal disturbances including motility alterations. Slow wave propagation coordinates gastrointestinal motility, and abnormal slow wave activity is thought to contribute to motility disorders. To date, however, little is known about the effect of acute ethanol on motility disturbances associated with slow wave activity. AIM To investigate the effect of ethanol on small intestine slow wave activity. METHODS Segments (3-5 cm long) were isolated from the rat duodenum, jejunum, and ileum and mounted in an organ bath superfused with a normal Tyrode solution or with 1, 3, or 5% ethanol containing Tyrode. The electrical activities were recorded using an array of 121 extracellular electrodes, and motility recordings were performed using a digital video camera. RESULTS The frequency and amplitude of slow wave activity were not altered at 1, 3, or 5% ethanol concentrations, but a significant drop in velocity was found at 3 and 5% ethanol. Furthermore, inexcitable areas appeared in a dose-dependent manner. Slow wave was sometimes also seen to propagate in a circular fashion, thereby describing a reentrant loop. Finally, in all duodenal, jejunal, and ileal segments, ethanol inhibited contractions and became fully quiescent at 3-5%. CONCLUSIONS These studies for the first time demonstrate that ethanol significantly inhibits slow wave and spike activity in a dose-dependent manner and could also initiate reentrant activities. Intestinal contractions were also inhibited in a dose-dependent manner. In conclusion, ethanol inhibits both slow wave activity and motor activity to cause ethanol-induced intestinal disturbances.
Collapse
|
41
|
Du P, Hameed A, Angeli TR, Lahr C, Abell TL, Cheng LK, O’Grady G. The impact of surgical excisions on human gastric slow wave conduction, defined by high-resolution electrical mapping and in silico modeling. Neurogastroenterol Motil 2015; 27:1409-22. [PMID: 26251163 PMCID: PMC4598186 DOI: 10.1111/nmo.12637] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2015] [Accepted: 06/20/2015] [Indexed: 12/12/2022]
Abstract
BACKGROUND Gastric contractions are coordinated by slow waves, generated by interstitial cells of Cajal (ICC). Gastric surgery affects slow wave conduction, potentially contributing to postoperative gastric dysfunction. However, the impact of gastric cuts on slow waves has not been comprehensively evaluated. This study aimed to define consequences of surgical excisions on gastric slow waves by applying high-resolution (HR) electrical mapping and in silico modeling. METHODS Patients undergoing gastric stimulator implantation (n = 10) underwent full-thickness stapled excisions (25 × 15 mm, distal corpus) for histological evaluation, enabling HR mapping (256 electrodes; 36 cm(2) ) over and adjacent to excisions. A biophysically based in silico model of bidirectionally coupled ICC networks was developed and applied to investigate the underlying conduction mechanisms and importance of excision orientation. KEY RESULTS Normal gastric slow waves propagated aborally (3.0 ± 0.2 cpm). Excisions induced complete conduction block and wavelets that rotated around blocks, then propagated rapidly circumferentially distal to the blocks (8.5 ± 1.2 vs normal 3.6 ± 0.4 mm/s; p < 0.01). This 'conduction anisotropy' homeostatically restored antegrade propagating gastric wavefronts distal to excisions. Excisions were associated with complex dysrhythmias in five patients: retrograde propagation (3/10), ectopics (3/10), functional blocks (2/10), and collisions (1/10). Simulations demonstrated conduction anisotropy emerged from bidirectional coupling within ICC layers and showed transverse incision length and orientation correlated with the degree of conduction distortion. CONCLUSIONS & INFERENCES Orienting incisions in the longitudinal gastric axis causes least disruption to electrical conduction and motility. However, if transverse incisions are made, a homeostatic mechanism of gastric conduction anisotropy compensates by restoring aborally propagating wavefronts. Complex dysrhythmias accompanying excisions could modify postoperative recovery in susceptible patients.
Collapse
Affiliation(s)
- Peng Du
- Auckland Bioengineering Institute, University of Auckland, New Zealand
| | - Ahmer Hameed
- Division of Surgery, Westmead Hospital, Sydney, Australia
| | - Timothy R. Angeli
- Auckland Bioengineering Institute, University of Auckland, New Zealand
| | - Christopher Lahr
- Department of Surgery, Mississippi Medical Center, Jackson, Mississippi, USA
| | - Thomas L. Abell
- Department of Gastroenterology, University of Louisville, Louisville, Kentucky, USA
| | - Leo K. Cheng
- Auckland Bioengineering Institute, University of Auckland, New Zealand,Department of Surgery, Vanderbilt University, Nashville, TN, USA
| | - Gregory O’Grady
- Auckland Bioengineering Institute, University of Auckland, New Zealand,Department of Surgery, University of Auckland, New Zealand
| |
Collapse
|
42
|
Lammers WJ. Inhomogeneities in the propagation of the slow wave in the stomach. Neurogastroenterol Motil 2015; 27:1349-53. [PMID: 26407766 DOI: 10.1111/nmo.12671] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/30/2015] [Accepted: 08/11/2015] [Indexed: 01/07/2023]
Abstract
The propagation of the slow wave in the stomach and its role in inducing sweeping peristaltic contractions toward the pylorus, essential for a proper digestion and emptying, have been studied for many years. Irregularities in the timing or in the pattern of propagation of the slow wave have been known to induce various gastric malfunctions and, recently, several types of gastric dysrhythmias have been described which could lead to gastric contraction abnormalities. In this study, Du et al. have analyzed the disturbances caused by a simple transmural incision in a human stomach, performed to obtain a biopsy of the muscle, on the propagation pattern of the slow wave. In addition, they show that such an incision may by itself also induce new types of gastric dysrhythmias. These results are important in demonstrating that the function of the stomach can easily be disturbed by such procedures. This mini-review describes several ways in which inhomogeneities in propagation may affect the conduction pattern of the slow wave, including the genesis of several dysrhythmias, and what is currently known about their impact on gastric contraction and digestion.
Collapse
Affiliation(s)
- W J Lammers
- formerly Department of Physiology, College of Medicine and Health Sciences, United Arab Emirates University, Al Ain, United Arab Emirates
| |
Collapse
|
43
|
Putney J, O'Grady G, Angeli TR, Paskaranandavadivel N, Cheng LK, Erickson JC. Determining the efficient inter-electrode distance for high-resolution mapping using a mathematical model of human gastric dysrhythmias. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2015:1448-1451. [PMID: 26736542 DOI: 10.1109/embc.2015.7318642] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Motility of the stomach is in part coordinated by an electrophysiological event called slow waves, which are generated by pacemaker cells called the interstitial cells of Cajal (ICC). In functional motility disorders, which can be associated with a reduction of ICC, dynamic slow wave dysrhythmias can occur. In recent years, high-resolution (HR) mapping techniques have been applied to describe both normal and dysrhythmic slow wave patterns. The main aim of this study was to inform gastric HR mapping array design by determining the efficient inter-electrode distance required to accurately capture normal and dysrhythmic gastric slow wave activity. A two-dimensional mathematical model was used to simulate normal activity and four types of reported slow wave dysrhythmias in human patients: ectopic activation, retrograde propagation, slow conduction, conduction block. For each case, the simulated data were re-sampled at 4, 6, 10, 12, 20 and 30mm inter-electrode distances. The accuracy of each distance was compared to a reference set sampled at 2mm inter-electrode distance, in terms of accuracy of velocity, using an ANOVA. Manual groupings were also conducted to test the ability of the human markers to distinguish separate cycles of slow waves as inter-electrode distance increases. The largest interelectrode distance for human gastric slow wave analysis, which produced both accurate grouping and velocity, was 10mm (CI [0.3 2.4]mms(-1); p<;0.05). Therefore an inter-electrode distance of less than 10mm was required to accurately describe the types of baseline and dysrhythmic activities reported in this study. However, it is likely that more spatially complex dysrhythmias, such as re-entry, may require finer inter-electrode distances.
Collapse
|
44
|
O'Grady G, Wang THH, Du P, Angeli T, Lammers WJEP, Cheng LK. Recent progress in gastric arrhythmia: pathophysiology, clinical significance and future horizons. Clin Exp Pharmacol Physiol 2015; 41:854-62. [PMID: 25115692 DOI: 10.1111/1440-1681.12288] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2014] [Revised: 07/11/2014] [Accepted: 07/14/2014] [Indexed: 01/27/2023]
Abstract
Gastric arrhythmia continues to be of uncertain diagnostic and therapeutic significance. However, recent progress has been substantial, with technical advances, theoretical insights and experimental discoveries offering new translational opportunities. The discoveries that interstitial cells of Cajal (ICC) generate slow waves and that ICC defects are associated with dysmotility have reinvigorated gastric arrhythmia research. Increasing evidence now suggests that ICC depletion and damage, network disruption and channelopathies may lead to aberrant slow wave initiation and conduction. Histological and high-resolution (HR) electrical mapping studies have now redefined the human 'gastric conduction system', providing an improved baseline for arrhythmia research. The application of HR mapping to arrhythmia has also generated important new insights into the spatiotemporal dynamics of arrhythmia onset and maintenance, resulting in the emergence of new provisional classification schemes. Meanwhile, the strong associations between gastric functional disorders and electrogastrography (EGG) abnormalities (e.g. in gastroparesis, unexplained nausea and vomiting and functional dyspepsia) continue to motivate deeper inquiries into the nature and causes of gastrointestinal arrhythmias. In future, technical progress in EGG methods, new HR mapping devices and software, wireless slow wave acquisition systems and improved gastric pacing devices may achieve validated applications in clinical practice. Neurohormonal factors in arrhythmogenesis also continue to be elucidated and a deepening understanding of these mechanisms may open opportunities for drug design for treating arrhythmias. However, for all translational goals, it remains to be seen whether arrhythmia can be corrected in a way that meaningfully improves organ function and symptoms in patients.
Collapse
Affiliation(s)
- Gregory O'Grady
- Department of Surgery, The University of Auckland, Auckland, New Zealand; Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | | | | | | | | | | |
Collapse
|
45
|
Angeli TR, Cheng LK, Du P, Wang THH, Bernard CE, Vannucchi MG, Faussone-Pellegrini MS, Lahr C, Vather R, Windsor JA, Farrugia G, Abell TL, O'Grady G. Loss of Interstitial Cells of Cajal and Patterns of Gastric Dysrhythmia in Patients With Chronic Unexplained Nausea and Vomiting. Gastroenterology 2015; 149:56-66.e5. [PMID: 25863217 PMCID: PMC4617790 DOI: 10.1053/j.gastro.2015.04.003] [Citation(s) in RCA: 160] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2014] [Revised: 03/24/2015] [Accepted: 04/01/2015] [Indexed: 01/18/2023]
Abstract
BACKGROUND & AIMS Chronic unexplained nausea and vomiting (CUNV) is a debilitating disease of unknown cause. Symptoms of CUNV substantially overlap with those of gastroparesis, therefore the diseases may share pathophysiologic features. We investigated this hypothesis by quantifying densities of interstitial cells of Cajal (ICCs) and mapping slow-wave abnormalities in patients with CUNV vs controls. METHODS Clinical data and gastric biopsy specimens were collected from 9 consecutive patients with at least 6 months of continuous symptoms of CUNV but normal gastric emptying who were treated at the University of Mississippi Medical Center, and from 9 controls (individuals free of gastrointestinal disease or diabetes). ICCs were counted and ultrastructural analyses were performed on tissue samples. Slow-wave propagation profiles were defined by high-resolution electrical mapping (256 electrodes; 36 cm(2)). Results from patients with CUNV were compared with those of controls as well as patients with gastroparesis who were studied previously by identical methods. RESULTS Patients with CUNV had fewer ICCs than controls (mean, 3.5 vs 5.6 bodies/field, respectively; P < .05), with mild ultrastructural abnormalities in the remaining ICCs. Slow-wave dysrhythmias were identified in all 9 subjects with CUNV vs only 1 of 9 controls. Dysrhythmias included abnormalities of initiation (stable ectopic pacemakers, unstable focal activities) and conduction (retrograde propagation, wavefront collisions, conduction blocks, and re-entry), operating across bradygastric, normal (range, 2.4-3.7 cycles/min), and tachygastric frequencies; dysrhythmias showed velocity anisotropy (mean, 3.3 mm/s longitudinal vs 7.6 mm/s circumferential; P < .01). ICCs were less depleted in patients with CUNV than in those with gastroparesis (mean, 3.5 vs 2.3 bodies/field, respectively; P < .05), but slow-wave dysrhythmias were similar between groups. CONCLUSIONS This study defined cellular and bioelectrical abnormalities in patients with CUNV, including the identification of slow-wave re-entry. Pathophysiologic features of CUNV were observed to be similar to those of gastroparesis, indicating that they could be spectra of the same disorder. These findings offer new insights into the pathogenesis of CUNV and may help to inform future treatments.
Collapse
Affiliation(s)
- Timothy R Angeli
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Leo K Cheng
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand; Department of Surgery, Vanderbilt University, Nashville, Tennessee
| | - Peng Du
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Tim Hsu-Han Wang
- Department of Surgery, University of Auckland, Auckland, New Zealand
| | - Cheryl E Bernard
- Division of Gastroenterology and Hepatology, Enteric Neurosciences Program, Mayo Clinic, Rochester, Minnesota
| | - Maria-Giuliana Vannucchi
- Histology and Embryology Research Unit, Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | | | - Christopher Lahr
- Department of Surgery, Mississippi Medical Center, Jackson, Mississippi
| | - Ryash Vather
- Department of Surgery, University of Auckland, Auckland, New Zealand
| | - John A Windsor
- Department of Surgery, University of Auckland, Auckland, New Zealand
| | - Gianrico Farrugia
- Division of Gastroenterology and Hepatology, Enteric Neurosciences Program, Mayo Clinic, Rochester, Minnesota
| | - Thomas L Abell
- Department of Gastroenterology, University of Louisville, Louisville, Kentucky
| | - Gregory O'Grady
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand; Department of Surgery, University of Auckland, Auckland, New Zealand.
| |
Collapse
|
46
|
O'Grady G, Angeli T, Du P, Cheng LK. Concerning the validity of gastrointestinal extracellular recordings. Physiol Rev 2015; 95:691-2. [PMID: 25834235 DOI: 10.1152/physrev.00005.2015] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Affiliation(s)
- Gregory O'Grady
- Department of Surgery, University of Auckland, Auckland, New Zealand; and Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Timothy Angeli
- Department of Surgery, University of Auckland, Auckland, New Zealand; and Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Peng Du
- Department of Surgery, University of Auckland, Auckland, New Zealand; and Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Leo K Cheng
- Department of Surgery, University of Auckland, Auckland, New Zealand; and Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| |
Collapse
|
47
|
Worth AA, Forrest AS, Peri LE, Ward SM, Hennig GW, Sanders KM. Regulation of gastric electrical and mechanical activity by cholinesterases in mice. J Neurogastroenterol Motil 2015; 21:200-16. [PMID: 25843073 PMCID: PMC4398240 DOI: 10.5056/jnm14120] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2014] [Revised: 11/15/2014] [Accepted: 11/18/2014] [Indexed: 12/03/2022] Open
Abstract
Background/Aims Gastric peristalsis begins in the orad corpus and propagates to the pylorus. Directionality of peristalsis depends upon orderly generation and propagation of electrical slow waves and a frequency gradient between proximal and distal pacemakers. We sought to understand how chronotropic agonists affect coupling between corpus and antrum. Methods Electrophysiological and imaging techniques were used to investigate regulation of gastric slow wave frequency by muscarinic agonists in mice. We also investigated the expression and role of cholinesterases in regulating slow wave frequency and motor patterns in the stomach. Results Both acetycholinesterase (Ache) and butyrylcholine esterase (Bche) are expressed in gastric muscles and AChE is localized to varicose processes of motor neurons. Inhibition of AChE in the absence of stimulation increased slow wave frequency in corpus and throughout muscle strips containing corpus and antrum. CCh caused depolarization and increased slow wave frequency. Stimulation of cholinergic neurons increased slow wave frequency but did not cause depolarization. Neostigmine (1 μM) increased slow wave frequency, but uncoupling between corpus and antrum was not detected. Motility mapping of contractile activity in gastric muscles showed similar effects of enteric nerve stimulation on the frequency and propagation of slow waves, but neostigmine (> 1 μM) caused aberrant contractile frequency and propagation and ectopic pacemaking. Conclusions Our data show that slow wave uncoupling is difficult to assess with electrical recording from a single or double sites and suggest that efficient metabolism of ACh released from motor neurons is an extremely important regulator of slow wave frequency and propagation and gastric motility patterns.
Collapse
Affiliation(s)
- Amy A Worth
- Faculty of Life Sciences, University of Manchester, Manchester, United Kingdom
| | | | - Lauren E Peri
- Department of Physiology and Cell Biology, University of Nevada School of Medicine, Reno, Nevada, USA
| | - Sean M Ward
- Department of Physiology and Cell Biology, University of Nevada School of Medicine, Reno, Nevada, USA
| | - Grant W Hennig
- Department of Physiology and Cell Biology, University of Nevada School of Medicine, Reno, Nevada, USA
| | - Kenton M Sanders
- Department of Physiology and Cell Biology, University of Nevada School of Medicine, Reno, Nevada, USA
| |
Collapse
|
48
|
Paskaranandavadivel N, Wang R, Sathar S, O’Grady G, Cheng LK, Farajidavar A. Multi-channel wireless mapping of gastrointestinal serosal slow wave propagation. Neurogastroenterol Motil 2015; 27:580-5. [PMID: 25599978 PMCID: PMC4380526 DOI: 10.1111/nmo.12515] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2014] [Accepted: 12/22/2014] [Indexed: 12/27/2022]
Abstract
BACKGROUND High-resolution (HR) extracellular mapping allows accurate profiling of normal and dysrhythmic slow wave patterns. A current limitation is that cables traverse the abdominal wall or a natural orifice, risking discomfort, dislodgement or infection. Wireless approaches offer advantages, but a multi-channel system is required, capable of recording slow waves and mapping propagation with high fidelity. METHODS A novel multi-channel (n = 7) wireless mapping system was developed and compared to a wired commercial system. Slow wave signals were recorded from the porcine gastric and intestinal serosa in vivo. Signals were simultaneously acquired using both systems, and were filtered and processed to map activation wavefronts. For validation, the frequency and amplitude of detected events were compared, together with the speed and direction of mapped wavefronts. KEY RESULTS The wireless device achieved comparable signal quality to the reference device, and slow wave frequencies were identical. Amplitudes of the acquired gastric and intestinal slow wave signals were consistent between the devices. During normal propagation, spatiotemporal mapping remained accurate in the wireless system, however, during ectopic dysrhythmic pacemaking, the lower sampling resolution of the wireless device led to reduced accuracy in spatiotemporal mapping. CONCLUSIONS & INFERENCES A novel multichannel wireless device is presented for mapping slow wave activity. The device achieved high quality signals, and has the potential to facilitate chronic monitoring studies and clinical translation of spatiotemporal mapping. The current implementation may be applied to detect normal patterns and dysrhythmia onset, but HR mapping with finely spaced arrays currently remains necessary to accurately define dysrhythmic patterns.
Collapse
Affiliation(s)
| | - Rui Wang
- School of Engineering and Computing Sciences, Department of Electrical and Computer Engineering, New York Institute of Technology, Old Westbury, New York, USA
| | - Shameer Sathar
- Auckland Bioengineering Institute, University of Auckland, New Zealand
| | - Gregory O’Grady
- Auckland Bioengineering Institute, University of Auckland, New Zealand
| | - Leo K Cheng
- Auckland Bioengineering Institute, University of Auckland, New Zealand,Department of Surgery, Vanderbilt University, Nashville, Tennessee, USA
| | - Aydin Farajidavar
- School of Engineering and Computing Sciences, Department of Electrical and Computer Engineering, New York Institute of Technology, Old Westbury, New York, USA
| |
Collapse
|
49
|
O'Grady G, Abell TL. Gastric arrhythmias in gastroparesis: low- and high-resolution mapping of gastric electrical activity. Gastroenterol Clin North Am 2015; 44:169-84. [PMID: 25667031 PMCID: PMC4323584 DOI: 10.1016/j.gtc.2014.11.013] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Gastric arrhythmias occur in gastroparesis but their significance is debated. An improved understanding is currently emerging, including newly-defined histopathologic abnormalities in gastroparesis. In particular, the observation that interstitial cells of Cajal are depleted and injured provides mechanisms for arrhythmogenesis in gastroparesis. Electrogastrography has been the dominant clinical method of arrhythmia analysis, but is limited by summative nature, low signal quality, and incomplete sensitivity and specificity. Recently, high-resolution (HR; multi-electrode) mapping has emerged, providing superior spatial data on arrhythmic patterns and mechanisms. However, HR mapping is invasive, and low-resolution approaches are being assessed as bridging techniques until endoscopic mapping is achieved.
Collapse
Affiliation(s)
- Gregory O'Grady
- Department of Surgery, University of Auckland, Private Bag 92019, Auckland 1142, New Zealand
| | - Thomas L Abell
- Division of Gastroenterology, GI Motility Clinic, University of Louisville, 220 Abraham Flexner Way, Suite 300, Louisville, KY 40202, USA.
| |
Collapse
|
50
|
Lammers WJ, van der Vusse GJ. Introduction to 'electrical propagation in smooth muscle organs'. Acta Physiol (Oxf) 2015; 213:347-8. [PMID: 25482098 DOI: 10.1111/apha.12434] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- W. J. Lammers
- Department of Physiology; College of Medicine & Health Sciences; UAE University; Al Ain United Arab Emirates
| | - G. J. van der Vusse
- Emeritus of Physiology; Cardiovascular Research Institute Maastricht; Maastricht University; Maastricht the Netherlands
| |
Collapse
|