1
|
Wang J, Li Y, El Fakhri G. Advances and Insights in Positron Emission Tomography Tracers for Metabotropic Glutamate Receptor 4 Imaging. J Med Chem 2024; 67:10517-10529. [PMID: 38924702 PMCID: PMC11290609 DOI: 10.1021/acs.jmedchem.3c02431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/28/2024]
Abstract
Positron emission tomography (PET) imaging employs positron-emitting radioisotopes to visualize biological processes in living subjects with high sensitivity and quantitative accuracy. As the most translational molecular imaging modality, PET can detect and image a wide range of radiotracers with minimal or no modification to parent drugs or targeting molecules. This Perspective provides a comprehensive analysis of developing PET radioligands using allosteric modulators for the metabotropic glutamate receptor subtype 4 (mGluR4) as a therapeutic target for neurological disorders. We focus on the selection of lead compounds from various chemotypes of mGluR4 positive allosteric modulators (PAMs) and discuss the challenges and systematic characterization required in developing brain-penetrant PET tracers specific for mGluR4. Through this analysis, we offer insights into the development and evaluation of PET ligands. Our review concludes that further research and development in this field hold great promise for discovering effective treatments for neurological disorders.
Collapse
Affiliation(s)
- Junfeng Wang
- Gordon Center for Medical Imaging, Massachusetts General Hospital & Department of Radiology, Harvard Medical School, Massachusetts, 02114, USA
| | - Yingbo Li
- State Key Laboratory of Natural and Biomimetic Drugs, School of Pharmaceutical Sciences, Peking University, Beijing, 100191, China
| | - Georges El Fakhri
- PET Center, School of Medicine, Yale University, Connecticut, 06520, USA
| |
Collapse
|
2
|
Pells S, Zeraatkar N, Kalluri KS, Moore SC, May M, Furenlid LR, Kupinski MA, Kuo PH, King MA. Correction of multiplexing artefacts in multi-pinhole SPECT through temporal shuttering, de-multiplexing of projections, and alternating reconstruction. Phys Med Biol 2024; 69:10.1088/1361-6560/ad4f47. [PMID: 38776948 PMCID: PMC11212123 DOI: 10.1088/1361-6560/ad4f47] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Accepted: 05/22/2024] [Indexed: 05/25/2024]
Abstract
Objective.Single-photon emission computed tomography (SPECT) with pinhole collimators can provide high-resolution imaging, but is often limited by low sensitivity. Acquiring projections simultaneously through multiple pinholes affords both high resolution and high sensitivity. However, the overlap of projections from different pinholes on detectors, known as multiplexing, has been shown to cause artefacts which degrade reconstructed images.Approach.Multiplexed projection sets were considered here using an analytic simulation model of AdaptiSPECT-C-a brain-dedicated multi-pinhole SPECT system. AdaptiSPECT-C has fully adaptable aperture shutters, so can acquire projections with a combination of multiplexed and non-multiplexed frames using temporal shuttering. Two strategies for reducing multiplex artefacts were considered: an algorithm to de-multiplex projections, and an alternating reconstruction strategy for projections acquired with a combination of multiplexed and non-multiplexed frames. Geometric and anthropomorphic digital phantoms were used to assess a number of metrics.Main results.Both de-multiplexing strategies showed a significant reduction in image artefacts and improved fidelity, image uniformity, contrast recovery and activity recovery (AR). In all cases, the two de-multiplexing strategies resulted in superior metrics to those from images acquired with only mux-free frames. The de-multiplexing algorithm provided reduced image noise and superior uniformity, whereas the alternating strategy improved contrast and AR.Significance.The use of these de-multiplexing algorithms means that multi-pinhole SPECT systems can acquire projections with more multiplexing without degradation of images.
Collapse
Affiliation(s)
- Sophia Pells
- Department of Radiology, University of Massachusetts Chan Medical School, Worcester, MA, United States of America
| | - Navid Zeraatkar
- Department of Radiology, University of Massachusetts Chan Medical School, Worcester, MA, United States of America
| | - Kesava S Kalluri
- Department of Radiology, University of Massachusetts Chan Medical School, Worcester, MA, United States of America
| | - Stephen C Moore
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, United States of America
| | - Micaehla May
- James C. Wyant College of Optical Sciences, The University of Arizona, Tucson, AZ, United States of America
| | - Lars R Furenlid
- James C. Wyant College of Optical Sciences, The University of Arizona, Tucson, AZ, United States of America
- Department of Medical Imaging, The University of Arizona, Tucson, AZ, United States of America
| | - Matthew A Kupinski
- James C. Wyant College of Optical Sciences, The University of Arizona, Tucson, AZ, United States of America
| | - Phillip H Kuo
- Department of Medical Imaging, The University of Arizona, Tucson, AZ, United States of America
- Department of Medicine, The University of Arizona, Tucson, AZ, United States of America
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ, United States of America
| | - Michael A King
- Department of Radiology, University of Massachusetts Chan Medical School, Worcester, MA, United States of America
| |
Collapse
|
3
|
Li Y, Wang J. Site-specifically radiolabeled nanobodies for imaging blood-brain barrier penetration and targeting in the brain. J Labelled Comp Radiopharm 2023; 66:444-451. [PMID: 37873934 PMCID: PMC10842159 DOI: 10.1002/jlcr.4069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 09/22/2023] [Accepted: 10/03/2023] [Indexed: 10/25/2023]
Abstract
Nanobodies (Nbs) hold significant potential in molecular imaging due to their unique characteristics. However, there are challenges to overcome when it comes to brain imaging. To address these obstacles, collaborative efforts and interdisciplinary research are needed. This article aims to raise awareness and encourage collaboration among researchers from various fields to find solutions for effective brain imaging using Nbs. By fostering cooperation and knowledge sharing, we can make progress in overcoming the existing limitations and pave the way for improved molecular imaging techniques in the future.
Collapse
Affiliation(s)
- Yingbo Li
- State Key Laboratory of Natural and Biomimetic Drugs, School of Pharmaceutical Sciences, Peking University, Beijing, China
| | - Junfeng Wang
- Gordon Center for Medical Imaging, Massachusetts General Hospital & Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
4
|
Moon SH, El Fakhri G, Zhang Z, Brownell AL, Wang J. Fully Automated Radiosynthesis of [ 18F]mG4P027 for mGluR4 Imaging. IRADIOLOGY 2023; 1:120-127. [PMID: 37496513 PMCID: PMC10371389 DOI: 10.1002/ird3.25] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2023] [Accepted: 05/18/2023] [Indexed: 07/28/2023]
Abstract
Fluorine-18 labeled N-(4-chloro-3-(((fluoro-18F)methyl-d2)thio)phenyl)picolinamide, [18F]mG4P027, is a potent positron emission tomography (PET) radiotracer for metabotropic glutamate receptor 4 (mGluR4). Our previous in vitro and in vivo evaluations have demonstrated that this tracer is promising for further translational studies. To automate the radiosynthesis of [18F]mG4P027, significant modifications were made to the manual process by carefully examining this process and addressing the root causes of the challenges associated with its automation. We successfully implemented its automated radiosynthesis using the TRACERlab FX2N module and consequently, obtained a high-purity radiolabeled [18F]mG4P027 in high yield, meeting the requirements for future human studies.
Collapse
Affiliation(s)
- Sung-Hyun Moon
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114 (USA)
| | - Georges El Fakhri
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114 (USA)
| | - Zhaoda Zhang
- Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114 (USA)
| | - Anna-Liisa Brownell
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114 (USA)
| | - Junfeng Wang
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114 (USA)
| |
Collapse
|
5
|
Terzi R. An Ensemble of Deep Learning Object Detection Models for Anatomical and Pathological Regions in Brain MRI. Diagnostics (Basel) 2023; 13:diagnostics13081494. [PMID: 37189595 DOI: 10.3390/diagnostics13081494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Revised: 04/13/2023] [Accepted: 04/17/2023] [Indexed: 05/17/2023] Open
Abstract
This paper proposes ensemble strategies for the deep learning object detection models carried out by combining the variants of a model and different models to enhance the anatomical and pathological object detection performance in brain MRI. In this study, with the help of the novel Gazi Brains 2020 dataset, five different anatomical parts and one pathological part that can be observed in brain MRI were identified, such as the region of interest, eye, optic nerves, lateral ventricles, third ventricle, and a whole tumor. Firstly, comprehensive benchmarking of the nine state-of-the-art object detection models was carried out to determine the capabilities of the models in detecting the anatomical and pathological parts. Then, four different ensemble strategies for nine object detectors were applied to boost the detection performance using the bounding box fusion technique. The ensemble of individual model variants increased the anatomical and pathological object detection performance by up to 10% in terms of the mean average precision (mAP). In addition, considering the class-based average precision (AP) value of the anatomical parts, an up to 18% AP improvement was achieved. Similarly, the ensemble strategy of the best different models outperformed the best individual model by 3.3% mAP. Additionally, while an up to 7% better FAUC, which is the area under the TPR vs. FPPI curve, was achieved on the Gazi Brains 2020 dataset, a 2% better FAUC score was obtained on the BraTS 2020 dataset. The proposed ensemble strategies were found to be much more efficient in finding the anatomical and pathological parts with a small number of anatomic objects, such as the optic nerve and third ventricle, and producing higher TPR values, especially at low FPPI values, compared to the best individual methods.
Collapse
Affiliation(s)
- Ramazan Terzi
- Department of Big Data and Artificial Intelligence, Digital Transformation Office of the Presidency of Republic of Türkiye, Ankara 06100, Turkey
- Department of Computer Engineering, Amasya University, Amasya 05100, Turkey
| |
Collapse
|
6
|
Hommer N, Kallab M, Schlatter A, Janku P, Werkmeister RM, Howorka K, Schmidl D, Schmetterer L, Garhöfer G. Neuro-vascular coupling and heart rate variability in patients with type II diabetes at different stages of diabetic retinopathy. Front Med (Lausanne) 2022; 9:1025853. [PMID: 36438055 PMCID: PMC9684184 DOI: 10.3389/fmed.2022.1025853] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Accepted: 10/26/2022] [Indexed: 11/11/2022] Open
Abstract
Aims/Hypothesis There is evidence that diabetes is accompanied by a break-down of functional hyperemia, an intrinsic mechanism of neural tissues to adapt blood flow to changing metabolic demands. However, to what extent functional hyperemia is altered in different stages of diabetic retinopathy (DR) in patients with type II diabetes is largely unknown. The current study set out to investigate flicker-induced retinal blood flow changes in patients with type II diabetes at different stages of DR. Materials and methods A total of 76 subjects were included in the present parallel-group study, of which 56 had diabetes with either no DR or different stages of non-proliferative DR (n = 29 no DR, 12 mild DR, 15 moderate to severe DR). In addition, 20 healthy subjects were included as controls. Retinal blood flow was assessed before and during visual stimulation using a combined measurement of retinal vessel calibers and blood velocity by the means of Doppler optical coherence tomography (OCT). To measure systemic autonomic nervous system function, heart rate variability (HRV) was assessed using a short-term orthostatic challenge test. Results In healthy controls, retinal blood flow increased by 40.4 ± 27.2% during flicker stimulation. Flicker responses in patients with DR were significantly decreased depending on the stage of the disease (no DR 37.7 ± 26.0%, mild DR 26.2 ± 28.2%, moderate to severe DR 22.3 ± 13.9%; p = 0.035, ANOVA). When assessing systemic autonomous neural function using HRV, normalized low frequency (LF) spectral power showed a significantly different response to the orthostatic maneuver in diabetic patients compared to healthy controls (p < 0.001). Conclusion/Interpretation Our study indicates that flicker induced hyperemia is reduced in patients with DR compared to healthy subjects. Further, this impairment is more pronounced with increasing severity of DR. Further studies are needed to elucidate mechanisms behind the reduced hyperemic response in patients with type II diabetes. Clinical trial registration [https://clinicaltrials.gov/], identifier [NCT03 552562].
Collapse
Affiliation(s)
- Nikolaus Hommer
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
| | - Martin Kallab
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
| | - Andreas Schlatter
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
- Hanusch Hospital, Karl Landsteiner Institute, Vienna, Austria
- Hanusch Hospital, Vienna Institute for Research in Ocular Surgery, Vienna, Austria
| | - Patrick Janku
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
| | - René M. Werkmeister
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Kinga Howorka
- Metabolic Competence Center, Medical University of Vienna, Vienna, Austria
| | - Doreen Schmidl
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
| | - Leopold Schmetterer
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
- Singapore National Eye Centre, Singapore Eye Research Institute, Singapore, Singapore
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore, Singapore
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore, Singapore
- Institute of Clinical and Experimental Ophthalmology, Basel, Switzerland
| | - Gerhard Garhöfer
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
- *Correspondence: Gerhard Garhöfer,
| |
Collapse
|
7
|
Zannoni EM, Yang C, Meng LJ. Design Study of an Ultrahigh Resolution Brain SPECT System Using a Synthetic Compound-Eye Camera Design With Micro-Slit and Micro-Ring Apertures. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:3711-3727. [PMID: 34255626 PMCID: PMC8711775 DOI: 10.1109/tmi.2021.3096920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
In this paper, we discuss the design study for a brain SPECT imaging system, referred to as the HelmetSPECT system, based on a spherical synthetic compound-eye (SCE) gamma camera design. The design utilizes a large number ( ∼ 500 ) of semiconductor detector modules, each coupled to an aperture with a very narrow opening for high-resolution SPECT imaging applications. In this study, we demonstrate that this novel system design could provide an excellent spatial resolution, a very high sensitivity, and a rich angular sampling without scanning motion over a clinically relevant field-of-view (FOV). These properties make the proposed HelmetSPECT system attractive for dynamic imaging of epileptic patients during seizures. In ictal SPECT, there is typically no prior information on where the seizures would happen, and both the imaging resolution and quantitative accuracy of the dynamic SPECT images would provide critical information for staging the seizures outbreak and refining the plans for subsequent surgical intervention.We report the performance evaluation and comparison among similar system geometries using non-conventional apertures, such as micro-ring and micro-slit, and traditional lofthole apertures. We demonstrate that the combination of ultrahigh-resolution imaging detectors, the SCE gamma camera design, and the micro-ring and micro-slit apertures would offer an interesting approach for the future ultrahigh-resolution clinical SPECT imaging systems without sacrificing system sensitivity and FOV.
Collapse
|
8
|
Lee MS, Cates JW, Gonzalez-Montoro A, Levin CS. High-resolution time-of-flight PET detector with 100 ps coincidence time resolution using a side-coupled phoswich configuration. Phys Med Biol 2021; 66. [PMID: 34106089 DOI: 10.1088/1361-6560/ac01b5] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2020] [Accepted: 05/14/2021] [Indexed: 12/23/2022]
Abstract
Photon time-of-flight (TOF) capability in positron emission tomography (PET) enables reconstructed image signal-to-noise ratio (SNR) improvement. With the coincidence time resolution (CTR) of 100 picosecond (ps), a five-fold SNR improvement can be achieved with a 40 cm diameter imaging subject, relative to a system without TOF capability. This 100 ps CTR can be achieved for aclinically relevantdetector design (crystal element length ≥20 mm with reasonably high crystal packing fraction) using a side-readout PET detector configuration that enables 511 keV photon interaction depth-independent light collection efficiency and lower variance in scintillation photon transit time to the silicon photomultiplier (SiPM). In this study, we propose a new concept of TOF-PET detector to achieve high (<2 mm) resolution, using a 'side-coupled phoswich' configuration, where two crystals with different decay times (τd) are coupled in a side-readout configuration to a common row of photosensors. The proposed design was validated and optimized with GATE Monte Carlo simulation studies to determine an efficient detector design. Based on the simulation results, a proof-of-concept side-coupled phoswich detector design was developed comprising two LSO crystals with the size of 1.9 × 1.9 × 10 mm3with decay times of 34.39 and 43.07 ns, respectively. The phoswich crystals were side-coupled to the same three 4 × 4 mm2SiPMs and detector performances were evaluated. As a result of the experimental evaluation, the side-coupled phoswich configuration achieved CTR of 107 ± 3 ps, energy resolution of 10.5% ± 1.21% at 511 keV and >95% accuracy in identifying interactions in the two adjacent 1.9 × 1.9 × 10 mm3crystal elements using the time-over-threshold technique. Based on our results, we can achieve excellent spatial and energy resolution in addition to ∼100 ps CTR with this novel detector design.
Collapse
Affiliation(s)
- Min Sun Lee
- Department of Radiology, Molecular Imaging Program at Stanford, School of Medicine, Stanford University, CA, United States of America.,Nuclear Emergency & Environmental Protection Division, Korea Atomic Energy Research Institute, Daejeon, Republic of Korea
| | - Joshua W Cates
- Applied Nuclear Physics Program, Lawrence Berkeley National Laboratory, CA, United States of America
| | - Andrea Gonzalez-Montoro
- Department of Radiology, Molecular Imaging Program at Stanford, School of Medicine, Stanford University, CA, United States of America
| | - Craig S Levin
- Department of Radiology, Molecular Imaging Program at Stanford, School of Medicine, Stanford University, CA, United States of America.,Department of Physics, Stanford University, CA, United States of America.,Department of Electrical Engineering, Stanford University, CA, United States of America.,Department of Bioengineering, Stanford University, CA, United States of America
| |
Collapse
|
9
|
Chaudhari AJ, Badawi RD. Application-specific nuclear medical in vivoimaging devices. Phys Med Biol 2021; 66. [PMID: 33770765 DOI: 10.1088/1361-6560/abf275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Accepted: 03/26/2021] [Indexed: 11/11/2022]
Abstract
Nuclear medical imaging devices, such as those enabling photon emission imaging (gamma camera, single photon emission computed tomography, or positron emission imaging), that are typically used in today's clinics are optimized for assessing large portions of the human body, and are classified as whole-body imaging systems. These systems have known limitations for organ imaging, therefore application-specific devices have been designed, constructed and evaluated. These devices, given their compact nature and superior technical characteristics, such as their higher detection sensitivity and spatial resolution for organ imaging compared to whole-body imaging systems, have shown promise for niche applications. Several of these devices have further been integrated with complementary anatomical imaging devices. The objectives of this review article are to (1) provide an overview of such application-specific nuclear imaging devices that were developed over the past two decades (in the twenty-first century), with emphasis on brain, cardiac, breast, and prostate imaging; and (2) discuss the rationale, advantages and challenges associated with the translation of these devices for routine clinical imaging. Finally, a perspective on the future prospects for application-specific devices is provided, which is that sustained effort is required both to overcome design limitations which impact their utility (where these exist) and to collect the data required to define their clinical value.
Collapse
Affiliation(s)
- Abhijit J Chaudhari
- Department of Radiology, University of California Davis, Sacramento, CA 95817, United States of America.,Center for Molecular and Genomic Imaging, University of California Davis, Davis, CA 95616, United States of America
| | - Ramsey D Badawi
- Department of Radiology, University of California Davis, Sacramento, CA 95817, United States of America.,Department of Biomedical Engineering, University of California Davis, Davis, CA 95616, United States of America
| |
Collapse
|
10
|
Huang J, Jiang S, Wagoner R, Yang H, Currier G, Jiang H. Three-dimensional optical imaging of brain activation during transcranial magnetic stimulation. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2021; 29:891-902. [PMID: 34397443 DOI: 10.3233/xst-210900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Repetitive transcranial magnetic stimulation (rTMS) of the brain is an effective clinical treatment for psychiatric disorders. Noninvasive neuroimaging during rTMS allows visualization of cortical brain activations and responses, and it is a potential tool for investigating the neurophysiological response occurring actively during stimulation. In this paper, we present a fast diffuse optical tomography (DOT) approach for three-dimensional brain mapping of hemodynamics during rTMS. Eight healthy subjects were enrolled in the study. These subjects received 10 Hz stimulation with 80%and 100%of resting motor threshold (rMT), respectively, for 4 seconds for each stimulation. Significant hemodynamic activation was observed in all cases with the strongest response when 100%rMT stimulation was applied. This work demonstrates that fast DOT has the potential to become a powerful tool for noninvasive three-dimensional imaging of the brain during rTMS.
Collapse
Affiliation(s)
- Jingyu Huang
- Department of Medical Engineering, University of South Florida, Tampa, Florida, USA
| | - Shixie Jiang
- Department of Psychiatry and Behavioral Neurosciences, University of South Florida, Tampa, Florida, USA
| | - Ryan Wagoner
- Department of Psychiatry and Behavioral Neurosciences, University of South Florida, Tampa, Florida, USA
| | - Hao Yang
- Department of Medical Engineering, University of South Florida, Tampa, Florida, USA
| | - Glenn Currier
- Department of Psychiatry and Behavioral Neurosciences, University of South Florida, Tampa, Florida, USA
| | - Huabei Jiang
- Department of Medical Engineering, University of South Florida, Tampa, Florida, USA
| |
Collapse
|
11
|
Zeraatkar N, Kalluri KS, Auer B, Konik A, Fromme TJ, Furenlid LR, Kuo PH, King MA. Investigation of Axial and Angular Sampling in Multi-Detector Pinhole-SPECT Brain Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:4209-4224. [PMID: 32763850 PMCID: PMC7875096 DOI: 10.1109/tmi.2020.3015079] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
We designed a dedicated multi-detector multi-pinhole brain SPECT scanner to generate images of higher quality compared to general-purpose systems. The system, AdaptiSPECT-C, is intended to adapt its sensitivity-resolution trade-off by varying its aperture configurations allowing both high-sensitivity dynamic and high-spatial-resolution static imaging. The current system design consists of 23 detector heads arranged in a truncated spherical geometry. In this work, we investigated the axial and angular sampling capability of the current stationary system design. Two data acquisition schemes using limited rotation of the gantry and two others using axial translation of the imaging bed were also evaluated concerning their impact on image quality through improved sampling. Increasing both angular and axial sampling in the current prototype system resulted in quantitative improvements in image quality metrics and qualitative appearance of the images as determined in studies with specifically selected phantoms. Visual improvements for the brain phantoms with clinical distributions were less pronounced but presented quantitative improvements in the fidelity (normalized root-mean-square error (NRMSE)) and striatal specific binding ratio (SBR) for a dopamine transporter (DAT) distribution, and in NRMSE and activity recovery for a brain perfusion distribution. More pronounced improvements with increased sampling were seen in contrast recovery coefficient, bias, and coefficient of variation for a lesion in the brain perfusion distribution. The negligible impact of the most cranial ring of detectors on axial sampling, but its significant impact on sensitivity and angular sampling in the cranial portion of the imaging volume-of-interest were also determined.
Collapse
|
12
|
Kessler M, Schierholz I, Mamach M, Wilke F, Hahne A, Büchner A, Geworski L, Bengel FM, Sandmann P, Berding G. Combined Brain-Perfusion SPECT and EEG Measurements Suggest Distinct Strategies for Speech Comprehension in CI Users With Higher and Lower Performance. Front Neurosci 2020; 14:787. [PMID: 32848560 PMCID: PMC7431776 DOI: 10.3389/fnins.2020.00787] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2020] [Accepted: 07/06/2020] [Indexed: 11/29/2022] Open
Abstract
Cochlear implantation constitutes a successful therapy of inner ear deafness, with the majority of patients showing good outcomes. There is, however, still some unexplained variability in outcomes with a number of cochlear-implant (CI) users, showing major limitations in speech comprehension. The current study used a multimodal diagnostic approach combining single-photon emission computed tomography (SPECT) and electroencephalography (EEG) to examine the mechanisms underlying speech processing in postlingually deafened CI users (N = 21). In one session, the participants performed a speech discrimination task, during which a 96-channel EEG was recorded and the perfusions marker 99mTc-HMPAO was injected intravenously. The SPECT scan was acquired 1.5 h after injection to measure the cortical activity during the speech task. The second session included a SPECT scan after injection without stimulation at rest. Analysis of EEG and SPECT data showed N400 and P600 event-related potentials (ERPs) particularly evoked by semantic violations in the sentences, and enhanced perfusion in a temporo-frontal network during task compared to rest, involving the auditory cortex bilaterally and Broca's area. Moreover, higher performance in testing for word recognition and verbal intelligence strongly correlated to the activation in this network during the speech task. However, comparing CI users with lower and higher speech intelligibility [median split with cutoff + 7.6 dB signal-to-noise ratio (SNR) in the Göttinger sentence test] revealed for CI users with higher performance additional activations of parietal and occipital regions and for those with lower performance stronger activation of superior frontal areas. Furthermore, SPECT activity was tightly coupled with EEG and cognitive abilities, as indicated by correlations between (1) cortical activation and the amplitudes in EEG, N400 (temporal and occipital areas)/P600 (parietal and occipital areas) and (2) between cortical activation in left-sided temporal and bilateral occipital/parietal areas and working memory capacity. These results suggest the recruitment of a temporo-frontal network in CI users during speech processing and a close connection between ERP effects and cortical activation in CI users. The observed differences in speech-evoked cortical activation patterns for CI users with higher and lower speech intelligibility suggest distinct processing strategies during speech rehabilitation with CI.
Collapse
Affiliation(s)
- Mariella Kessler
- Department of Nuclear Medicine, Hannover Medical School, Hanover, Germany
- Cluster of Excellence Hearing4all, Hannover Medical School, University of Oldenburg, Oldenburg, Germany
| | - Irina Schierholz
- Cluster of Excellence Hearing4all, Hannover Medical School, University of Oldenburg, Oldenburg, Germany
- Department of Otorhinolaryngology, Hannover Medical School, Hanover, Germany
- Department of Otorhinolaryngology, University of Cologne, Cologne, Germany
| | - Martin Mamach
- Cluster of Excellence Hearing4all, Hannover Medical School, University of Oldenburg, Oldenburg, Germany
- Department of Medical Physics and Radiation Protection, Hannover Medical School, Hanover, Germany
| | - Florian Wilke
- Department of Medical Physics and Radiation Protection, Hannover Medical School, Hanover, Germany
| | - Anja Hahne
- Department of Otorhinolaryngology, Faculty of Medicine Carl Gustav Carus, Saxonian Cochlear Implant Center, Technical University Dresden, Dresden, Germany
| | - Andreas Büchner
- Cluster of Excellence Hearing4all, Hannover Medical School, University of Oldenburg, Oldenburg, Germany
- Department of Otorhinolaryngology, Hannover Medical School, Hanover, Germany
| | - Lilli Geworski
- Department of Medical Physics and Radiation Protection, Hannover Medical School, Hanover, Germany
| | - Frank M. Bengel
- Department of Nuclear Medicine, Hannover Medical School, Hanover, Germany
| | - Pascale Sandmann
- Department of Otorhinolaryngology, University of Cologne, Cologne, Germany
| | - Georg Berding
- Department of Nuclear Medicine, Hannover Medical School, Hanover, Germany
- Cluster of Excellence Hearing4all, Hannover Medical School, University of Oldenburg, Oldenburg, Germany
| |
Collapse
|
13
|
Abstract
Positron emission tomography (PET) has a long history in the assessment of brain physiology and pathology; however, its initial use was limited to more academic and scientific settings. This changed radically with the clinical introduction of PET–computed tomography (PET-CT). PET-CT has become an integral part of the radiological armamentarium, especially in the assessment of patients with oncological or cardiovascular disorders. It has until now not found a clear role in neuroradiology. Indeed, magnetic resonance techniques have proven superior for the investigation of brain tumors and inflammatory diseases. However, some newer applications are emerging that can re-center PET-CT clearly in the neuroradiological world such as the investigation of vascular diseases.
Collapse
|
14
|
Gonzalez AJ, Pincay EJ, Canizares G, Lamprou E, Sanchez S, Catret JV, Jimenez-Serrano S, Cabello J, Schwaiger M, Iborra A, Merlin T, Gonzalez-Montoro A, Visvikis D, Benlloch JM, Vidal LF, Barbera J, Aussenhofer S, Hernandez L, Moliner L, Sanchez F, Correcher C. Initial Results of the MINDView PET Insert Inside the 3T mMR. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2019. [DOI: 10.1109/trpms.2018.2866899] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
15
|
Gonzalez AJ, Sanchez F, Benlloch JM. Organ-Dedicated Molecular Imaging Systems. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2018. [DOI: 10.1109/trpms.2018.2846745] [Citation(s) in RCA: 47] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
16
|
Jackson S, Weingart J, Nduom EK, Harfi TT, George RT, McAreavey D, Ye X, Anders NM, Peer C, Figg WD, Gilbert M, Rudek MA, Grossman SA. The effect of an adenosine A 2A agonist on intra-tumoral concentrations of temozolomide in patients with recurrent glioblastoma. Fluids Barriers CNS 2018; 15:2. [PMID: 29332604 PMCID: PMC5767971 DOI: 10.1186/s12987-017-0088-8] [Citation(s) in RCA: 51] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2017] [Accepted: 12/26/2017] [Indexed: 01/29/2023] Open
Abstract
Background The blood–brain barrier (BBB) severely limits the entry of systemically administered drugs including chemotherapy to the brain. In rodents, regadenoson activation of adenosine A2A receptors causes transient BBB disruption and increased drug concentrations in normal brain. This study was conducted to evaluate if activation of A2A receptors would increase intra-tumoral temozolomide concentrations in patients with glioblastoma. Methods Patients scheduled for a clinically indicated surgery for recurrent glioblastoma were eligible. Microdialysis catheters (MDC) were placed intraoperatively, and the positions were documented radiographically. On post-operative day #1, patients received oral temozolomide (150 mg/m2). On day #2, 60 min after oral temozolomide, patients received one intravenous dose of regadenoson (0.4 mg). Blood and MDC samples were collected to determine temozolomide concentrations. Results Six patients were enrolled. Five patients had no complications from the MDC placement or regadenoson and had successful collection of blood and dialysate samples. The mean plasma AUC was 16.4 ± 1.4 h µg/ml for temozolomide alone and 16.6 ± 2.87 h µg/ml with addition of regadenoson. The mean dialysate AUC was 2.9 ± 1.2 h µg/ml with temozolomide alone and 3.0 ± 1.7 h µg/ml with regadenoson. The mean brain:plasma AUC ratio was 18.0 ± 7.8 and 19.1 ± 10.7% for temozolomide alone and with regadenoson respectively. Peak concentration and Tmax in brain were not significantly different. Conclusions Although previously shown to be efficacious in rodents to increase varied size agents to cross the BBB, our data suggest that regadenoson does not increase temozolomide concentrations in brain. Further studies exploring alternative doses and schedules are needed; as transiently disrupting the BBB to facilitate drug entry is of critical importance in neuro-oncology. Electronic supplementary material The online version of this article (10.1186/s12987-017-0088-8) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Sadhana Jackson
- Brain Cancer Program, Johns Hopkins University, David H. Koch Cancer Research Building II, 1550 Orleans Street, Room 1M16, Baltimore, MD, 21287, USA. .,Neuro-Oncology Branch, NCI/NIH, 9030 Old Georgetown Rd, Building 82, Bethesda, MD, 20892, USA.
| | - Jon Weingart
- School of Medicine, Department of Neurosurgery, Johns Hopkins University, Baltimore, MD, 21287, USA
| | - Edjah K Nduom
- Surgical Neurology Branch, NINDS/NIH, 10 Center Drive, 3D20, Bethesda, MD, 20814, USA
| | - Thura T Harfi
- David Heart & Lung Research Institute, The Ohio State University, 374 12th Avenue, Suite 200, Columbus, OH, 43210, USA
| | - Richard T George
- Heart and Vascular Institute, Johns Hopkins University, 600 N. Wolfe Street, Sheikh Zayed Tower, Baltimore, MD, 21287, USA
| | - Dorothea McAreavey
- Critical Care Medicine Department, Nuclear Cardiology Section, NIH Clinical Center, 10 Center Drive, Bethesda, MD, 20892, USA
| | - Xiaobu Ye
- School of Medicine, Department of Neurosurgery, Johns Hopkins University, Baltimore, MD, 21287, USA
| | - Nicole M Anders
- Cancer Chemical and Structural Biology and Analytical Pharmacology Core Laboratory, Johns Hopkins University, Bunting-Blaustein Cancer Research Building I, 1650 Orleans Street, CRB1 Room 1M52, Baltimore, MD, 21231, USA
| | - Cody Peer
- Clinical Pharmacology, NCI/NIH, 10 Center Drive, 5A01, Bethesda, MD, 20814, USA
| | - William D Figg
- Clinical Pharmacology, NCI/NIH, 10 Center Drive, 5A01, Bethesda, MD, 20814, USA
| | - Mark Gilbert
- Neuro-Oncology Branch, NCI/NIH, 9030 Old Georgetown Rd, Building 82, Bethesda, MD, 20892, USA
| | - Michelle A Rudek
- Cancer Chemical and Structural Biology and Analytical Pharmacology Core Laboratory, Johns Hopkins University, Bunting-Blaustein Cancer Research Building I, 1650 Orleans Street, CRB1 Room 1M52, Baltimore, MD, 21231, USA
| | - Stuart A Grossman
- Brain Cancer Program, Johns Hopkins University, David H. Koch Cancer Research Building II, 1550 Orleans Street, Room 1M16, Baltimore, MD, 21287, USA
| |
Collapse
|
17
|
Jackson S, George RT, Lodge MA, Piotrowski A, Wahl RL, Gujar SK, Grossman SA. The effect of regadenoson on the integrity of the human blood-brain barrier, a pilot study. J Neurooncol 2017; 132:513-519. [PMID: 28315063 DOI: 10.1007/s11060-017-2404-1] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2016] [Accepted: 03/12/2017] [Indexed: 10/19/2022]
Abstract
Regadenoson is an FDA approved adenosine receptor agonist which increases blood-brain barrier (BBB) permeability in rodents. Regadenoson is used clinically for pharmacologic cardiac stress testing using SPECT or CT imaging agents that do not cross an intact BBB. This study was conducted to determine if standard doses of regadenoson transiently disrupt the human BBB allowing higher concentrations of systemically administered imaging agents to enter the brain. Patients without known intracranial disease undergoing clinically indicated pharmacologic cardiac stress tests were eligible for this study. They received regadenoson (0.4 mg) followed by brain imaging with either 99mTc-sestamibi for SPECT or visipaque for CT imaging. Pre- and post-regadenoson penetration of imaging agents into brain were quantified [SPECT: radioactive counts, CT: Hounsfield units (HU)] and compared using a matched-pairs t-test. Twelve patients (33% male, median 60 yo) were accrued: 7 SPECT and 5 CT. No significant differences were noted in pre- and post-regadenoson values using mean radionuclide counts (726 vs. 757) or HU (29 vs. 30). While animal studies have demonstrated that regadenoson transiently increases the permeability of the BBB to dextran and temozolomide, we were unable to document changes in the penetration of contrast agents in humans with intact BBB using the FDA approved doses of regadenoson for cardiac evaluation. Further studies are needed exploring alternate regadenoson dosing, schedules, and studies in patients with brain tumors; as transiently disrupting the BBB to improve drug entry into the brain is critical to improving the care of patients with CNS malignancies.
Collapse
Affiliation(s)
- Sadhana Jackson
- Brain Cancer Program, Johns Hopkins University, David H. Koch Cancer Research Building II, 1550 Orleans Street, Room 1M16, Baltimore, MD, 21287, USA
| | - Richard T George
- Heart and Vascular Institute, Johns Hopkins University, 600 N. Wolfe Street, Sheikh Zayed Tower, Baltimore, MD, 21287, USA
| | - Martin A Lodge
- Nuclear Medicine, Russell H. Morgan Dept. of Radiology and Radiological Sciences, Johns Hopkins University, 601 Caroline St, Baltimore, MD, 21231, USA
| | - Anna Piotrowski
- Brain Cancer Program, Johns Hopkins University, David H. Koch Cancer Research Building II, 1550 Orleans Street, Room 1M16, Baltimore, MD, 21287, USA
| | - Richard L Wahl
- Nuclear Medicine, Russell H. Morgan Dept. of Radiology and Radiological Sciences, Johns Hopkins University, 601 Caroline St, Baltimore, MD, 21231, USA.,Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 South Kingshighway Blvd., St. Louis, MO, 63110, USA
| | - Sachin K Gujar
- Radiology and Radiological Science, Johns Hopkins University, 600 N. Wolfe Street, Sheikh Zayed Tower, Baltimore, MD, 21287, USA
| | - Stuart A Grossman
- Brain Cancer Program, Johns Hopkins University, David H. Koch Cancer Research Building II, 1550 Orleans Street, Room 1M16, Baltimore, MD, 21287, USA.
| |
Collapse
|
18
|
Abstract
Single-photon emission computed tomography (SPECT) is a functional nuclear imaging technique that allows visualization and quantification of different in vivo physiologic and pathologic features of brain neurobiology. It has been used for many years in diagnosis of several neurologic and psychiatric disorders. In this chapter, we discuss the current state-of-the-art of SPECT imaging of brain perfusion and dopamine transporter (DAT) imaging. Brain perfusion SPECT imaging plays an important role in the localization of the seizure onset zone in patients with refractory epilepsy. In cerebrovascular disease, it can be useful in determining the cerebrovascular reserve. After traumatic brain injury, SPECT has shown perfusion abnormalities despite normal morphology. In the context of organ donation, the diagnosis of brain death can be made with high accuracy. In neurodegeneration, while amyloid or (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET) are the nuclear diagnostic tools of preference for early and differential diagnosis of dementia, perfusion SPECT imaging can be useful, albeit with slightly lower accuracy. SPECT imaging of the dopamine transporter system is widely available in Europe and Asia, but since recently also in the USA, and has been accepted as an important diagnostic tool in the early and differential diagnosis of parkinsonism in patients with unclear clinical features. The combination of perfusion SPECT (or FDG-PET) and DAT imaging provides differential diagnosis between idiopathic Parkinson's disease, Parkinson-plus syndromes, dementia with Lewy bodies, and essential tremor.
Collapse
Affiliation(s)
- Karolien Goffin
- Division of Nuclear Medicine, University Hospital Leuven and KU Leuven, Leuven, Belgium
| | - Koen van Laere
- Division of Nuclear Medicine, University Hospital Leuven and KU Leuven, Leuven, Belgium.
| |
Collapse
|
19
|
Amyot F, Arciniegas DB, Brazaitis MP, Curley KC, Diaz-Arrastia R, Gandjbakhche A, Herscovitch P, Hinds SR, Manley GT, Pacifico A, Razumovsky A, Riley J, Salzer W, Shih R, Smirniotopoulos JG, Stocker D. A Review of the Effectiveness of Neuroimaging Modalities for the Detection of Traumatic Brain Injury. J Neurotrauma 2015; 32:1693-721. [PMID: 26176603 PMCID: PMC4651019 DOI: 10.1089/neu.2013.3306] [Citation(s) in RCA: 114] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
The incidence of traumatic brain injury (TBI) in the United States was 3.5 million cases in 2009, according to the Centers for Disease Control and Prevention. It is a contributing factor in 30.5% of injury-related deaths among civilians. Additionally, since 2000, more than 260,000 service members were diagnosed with TBI, with the vast majority classified as mild or concussive (76%). The objective assessment of TBI via imaging is a critical research gap, both in the military and civilian communities. In 2011, the Department of Defense (DoD) prepared a congressional report summarizing the effectiveness of seven neuroimaging modalities (computed tomography [CT], magnetic resonance imaging [MRI], transcranial Doppler [TCD], positron emission tomography, single photon emission computed tomography, electrophysiologic techniques [magnetoencephalography and electroencephalography], and functional near-infrared spectroscopy) to assess the spectrum of TBI from concussion to coma. For this report, neuroimaging experts identified the most relevant peer-reviewed publications and assessed the quality of the literature for each of these imaging technique in the clinical and research settings. Although CT, MRI, and TCD were determined to be the most useful modalities in the clinical setting, no single imaging modality proved sufficient for all patients due to the heterogeneity of TBI. All imaging modalities reviewed demonstrated the potential to emerge as part of future clinical care. This paper describes and updates the results of the DoD report and also expands on the use of angiography in patients with TBI.
Collapse
Affiliation(s)
- Franck Amyot
- The Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, Maryland
- Center for Neuroscience and Regenerative Medicine, Uniformed Services University of the Health Sciences, Bethesda, Maryland
| | - David B. Arciniegas
- Beth K. and Stuart C. Yudofsky Division of Neuropsychiatry, Baylor College of Medicine, Houston, Texas
- Brain Injury Research, TIRR Memorial Hermann, Houston, Texas
| | | | - Kenneth C. Curley
- Combat Casualty Care Directorate (RAD2), U.S. Army Medical Research and Materiel Command, Fort Detrick, Maryland
| | - Ramon Diaz-Arrastia
- Center for Neuroscience and Regenerative Medicine, Uniformed Services University of the Health Sciences, Bethesda, Maryland
| | - Amir Gandjbakhche
- The Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, Maryland
| | - Peter Herscovitch
- Positron Emission Tomography Department, National Institutes of Health Clinical Center, Bethesda, Maryland
| | - Sidney R. Hinds
- Defense and Veterans Brain Injury Center, Defense Centers of Excellence for Psychological Health and Traumatic Brain Injury Silver Spring, Maryland
| | - Geoffrey T. Manley
- Brain and Spinal Injury Center, Department of Neurological Surgery, University of California, San Francisco, San Francisco, California
| | - Anthony Pacifico
- Congressionally Directed Medical Research Programs, Fort Detrick, Maryland
| | | | - Jason Riley
- Queens University, Kingston, Ontario, Canada
- ArcheOptix Inc., Picton, Ontario, Canada
| | - Wanda Salzer
- Congressionally Directed Medical Research Programs, Fort Detrick, Maryland
| | - Robert Shih
- Walter Reed National Military Medical Center, Bethesda, Maryland
| | - James G. Smirniotopoulos
- Department of Radiology, Neurology, and Biomedical Informatics, Uniformed Services University of the Health Sciences, Bethesda, Maryland
| | - Derek Stocker
- Walter Reed National Military Medical Center, Bethesda, Maryland
| |
Collapse
|
20
|
Samara A, Tsangaris GT. Brain asymmetry: both sides of the story. Expert Rev Proteomics 2014; 8:693-703. [DOI: 10.1586/epr.11.62] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
21
|
Abstract
Stroke and cerebrovascular diseases are major causes of mortality, morbidity, and disability. Nuclear Medicine, primarily via tomographic methods, has made significant contributions to the understanding of the hemodynamic and metabolic consequences of cerebrovascular diseases. In this review, the findings in acute, subacute, and chronic cerebrovascular diseases are described. Many of the pathophysiologic processes and consequences that follow stroke, including completed infarct core, adjacent penumbra, and diaschisis, have been investigated with Nuclear Medicine, and stroke outcome may be related to these phenomena. Additional topics included in this review are cerebrovascular reserve tests and multi-infarct dementia. Finally, Nuclear Medicine investigations of stroke recovery and cerebral plasticity appear to indicate that enhanced activity of preexisting networks, rather than substitution of function, represents the most important mechanism of improvement in chronic stroke rehabilitation.
Collapse
Affiliation(s)
- David H Lewis
- Division of Nuclear Medicine, Department of Radiology, University of Washington School of Medicine, Seattle, WA 98104, USA.
| | | | | |
Collapse
|
22
|
Carter E, Coles JP. Imaging in the diagnosis and prognosis of traumatic brain injury. EXPERT OPINION ON MEDICAL DIAGNOSTICS 2012; 6:541-554. [PMID: 23480836 DOI: 10.1517/17530059.2012.707188] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
INTRODUCTION Traumatic brain injury (TBI) is a major cause of death and disability worldwide. Improved understanding of the impact of head injury and the extent and development of neuronal loss and cognitive dysfunction could lead to improved therapy and outcome for patients. AREAS COVERED This paper reviews the currently available imaging techniques and defines their role in the diagnosis, management and prediction of outcome following traumatic brain injury. These imaging techniques provide delineation of the structural, physiological and functional derangements that result following acute injury, and map their development and association with late functional deficits. Imaging tools also have a role in defining the pathophysiological mechanisms responsible for further neuronal loss following the primary injury. Finally, this paper provides an overview of the role of functional imaging in classifying unresponsive coma and defining functional reorganisation of the brain following injury. EXPERT OPINION Brain imaging is of key importance in TBI management, enabling efficient and accurate diagnoses to be made, informing management decisions and contributing to prognostication. Developments in imaging techniques promise to improve understanding of the structural and functional derangements, improve management and guide the development and implementation of novel neuroprotective strategies following head injury.
Collapse
Affiliation(s)
- Eleanor Carter
- Division of Anaesthesia, University of Cambridge, Addenbrooke's Hospital , Cambridge, CB2 0AA , UK +01223 217889 ; +01223 217887 ;
| | | |
Collapse
|
23
|
Mansi L, Ciarmiello A, Cuccurullo V. PET/MRI and the revolution of the third eye. Eur J Nucl Med Mol Imaging 2012; 39:1519-24. [DOI: 10.1007/s00259-012-2185-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
24
|
Bian ZX. Novel insights about the mechanism of visceral hypersensitivity in maternally separated rats. Neurogastroenterol Motil 2012; 24:593-6. [PMID: 22709237 DOI: 10.1111/j.1365-2982.2012.01951.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Visceral hypersensitivity (VHS) is one of the most important characteristics of functional gastrointestinal disorders, including irritable bowel syndrome (IBS). Stress, whether physical or psychological, is known to be a crucial factor for inducing and maintaining visceral sensitivity in humans and rodents, but how stress induces VHS is not fully understood. In a recent study published in Neurogastroenterology and Motility, Wouters et al. demonstrate, for the first time, that maternal separation induces activation of periaqueductal gray (PAG), the hippocampus and the somatosensory cortex concomitantly with increased deactivation of the pre-frontal cortex. The findings provide insight on the role of maternal separation in inducing regional cerebral blood flow changes and cerebral plasticity. These novel insights on the role of central activation in the modulation of stress-induced VHS add to our growing understanding of the mechanisms that underlie VHS and suggest potential new drug development targets in stress-related diseases, including IBS.
Collapse
Affiliation(s)
- Z X Bian
- School of Chinese Medicine, Hong Kong Baptist University, HKSRA, Hong Kong, China.
| |
Collapse
|
25
|
|