1
|
Champendal M, Ribeiro RST, Müller H, Prior JO, Sá Dos Reis C. Nuclear medicine technologists practice impacted by AI denoising applications in PET/CT images. Radiography (Lond) 2024; 30:1232-1239. [PMID: 38917681 DOI: 10.1016/j.radi.2024.06.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Revised: 05/24/2024] [Accepted: 06/11/2024] [Indexed: 06/27/2024]
Abstract
PURPOSE Artificial intelligence (AI) in positron emission tomography/computed tomography (PET/CT) can be used to improve image quality when it is useful to reduce the injected activity or the acquisition time. Particular attention must be paid to ensure that users adopt this technological innovation when outcomes can be improved by its use. The aim of this study was to identify the aspects that need to be analysed and discussed to implement an AI denoising PET/CT algorithm in clinical practice, based on the representations of Nuclear Medicine Technologists (NMT) from Western-Switzerland, highlighting the barriers and facilitators associated. METHODS Two focus groups were organised in June and September 2023, involving ten voluntary participants recruited from all types of medical imaging departments, forming a diverse sample of NMT. The interview guide followed the first stage of the revised model of Ottawa of Research Use. A content analysis was performed following the three-stage approach described by Wanlin. Ethics cleared the study. RESULTS Clinical practice, workload, knowledge and resources were de 4 themes identified as necessary to be thought before implementing an AI denoising PET/CT algorithm by ten NMT participants (aged 31-60), not familiar with this AI tool. The main barriers to implement this algorithm included workflow challenges, resistance from professionals and lack of education; while the main facilitators were explanations and the availability of support to ask questions such as a "local champion". CONCLUSION To implement a denoising algorithm in PET/CT, several aspects of clinical practice need to be thought to reduce the barriers to its implementation such as the procedures, the workload and the available resources. Participants emphasised also the importance of clear explanations, education, and support for successful implementation. IMPLICATIONS FOR PRACTICE To facilitate the implementation of AI tools in clinical practice, it is important to identify the barriers and propose strategies that can mitigate it.
Collapse
Affiliation(s)
- M Champendal
- School of Health Sciences HESAV, HES-SO, University of Applied Sciences Western Switzerland: Lausanne, CH, Switzerland; Faculty of Biology and Medicine, University of Lausanne, Lausanne, CH, Switzerland.
| | - R S T Ribeiro
- School of Health Sciences HESAV, HES-SO, University of Applied Sciences Western Switzerland: Lausanne, CH, Switzerland.
| | - H Müller
- Informatics Institute, University of Applied Sciences Western Switzerland (HES-SO Valais) Sierre, CH, Switzerland; Medical Faculty, University of Geneva, CH, Switzerland.
| | - J O Prior
- Faculty of Biology and Medicine, University of Lausanne, Lausanne, CH, Switzerland; Nuclear Medicine and Molecular Imaging Department, Lausanne University Hospital (CHUV): Lausanne, CH, Switzerland.
| | - C Sá Dos Reis
- School of Health Sciences HESAV, HES-SO, University of Applied Sciences Western Switzerland: Lausanne, CH, Switzerland.
| |
Collapse
|
2
|
Caldarella C, De Risi M, Massaccesi M, Miccichè F, Bussu F, Galli J, Rufini V, Leccisotti L. Role of 18F-FDG PET/CT in Head and Neck Squamous Cell Carcinoma: Current Evidence and Innovative Applications. Cancers (Basel) 2024; 16:1905. [PMID: 38791983 PMCID: PMC11119768 DOI: 10.3390/cancers16101905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Revised: 05/08/2024] [Accepted: 05/13/2024] [Indexed: 05/26/2024] Open
Abstract
This article provides an overview of the use of 18F-FDG PET/CT in various clinical scenarios of head-neck squamous cell carcinoma, ranging from initial staging to treatment-response assessment, and post-therapy follow-up, with a focus on the current evidence, debated issues, and innovative applications. Methodological aspects and the most frequent pitfalls in head-neck imaging interpretation are described. In the initial work-up, 18F-FDG PET/CT is recommended in patients with metastatic cervical lymphadenectomy and occult primary tumor; moreover, it is a well-established imaging tool for detecting cervical nodal involvement, distant metastases, and synchronous primary tumors. Various 18F-FDG pre-treatment parameters show prognostic value in terms of disease progression and overall survival. In this scenario, an emerging role is played by radiomics and machine learning. For radiation-treatment planning, 18F-FDG PET/CT provides an accurate delineation of target volumes and treatment adaptation. Due to its high negative predictive value, 18F-FDG PET/CT, performed at least 12 weeks after the completion of chemoradiotherapy, can prevent unnecessary neck dissections. In addition to radiomics and machine learning, emerging applications include PET/MRI, which combines the high soft-tissue contrast of MRI with the metabolic information of PET, and the use of PET radiopharmaceuticals other than 18F-FDG, which can answer specific clinical needs.
Collapse
Affiliation(s)
- Carmelo Caldarella
- Nuclear Medicine Unit, Department of Radiology and Oncologic Radiotherapy, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy; (C.C.); (M.D.R.); (L.L.)
| | - Marina De Risi
- Nuclear Medicine Unit, Department of Radiology and Oncologic Radiotherapy, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy; (C.C.); (M.D.R.); (L.L.)
| | - Mariangela Massaccesi
- Radiation Oncology Unit, Department of Radiology and Oncologic Radiotherapy, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy;
| | - Francesco Miccichè
- Radiation Oncology Unit, Ospedale Isola Tiberina—Gemelli Isola, 00186 Rome, Italy;
| | - Francesco Bussu
- Otorhinolaryngology Operative Unit, Azienda Ospedaliero Universitaria Sassari, 07100 Sassari, Italy;
- Department of Medicine, Surgery and Pharmacy, University of Sassari, 07100 Sassari, Italy
| | - Jacopo Galli
- Otorhinolaryngology Unit, Department of Neurosciences, Sensory Organs and Thorax, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy;
- Section of Otolaryngology, Department of Head-Neck and Sensory Organs, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Vittoria Rufini
- Nuclear Medicine Unit, Department of Radiology and Oncologic Radiotherapy, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy; (C.C.); (M.D.R.); (L.L.)
- Section of Nuclear Medicine, Department of Radiological Sciences and Hematology, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Lucia Leccisotti
- Nuclear Medicine Unit, Department of Radiology and Oncologic Radiotherapy, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy; (C.C.); (M.D.R.); (L.L.)
- Section of Nuclear Medicine, Department of Radiological Sciences and Hematology, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| |
Collapse
|
3
|
Ulaner GA, Vaz SC, Groheux D. Quarter-Century Transformation of Oncology: Positron Emission Tomography for Patients with Breast Cancer. PET Clin 2024; 19:147-162. [PMID: 38177052 DOI: 10.1016/j.cpet.2023.12.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2024]
Abstract
PET radiotracers have become indispensable in the care of patients with breast cancer. 18F-fluorodeoxyglucose has become the preferred method of many oncologists for systemic staging of breast cancer at initial diagnosis, detecting recurrent disease, and for measuring treatment response after therapy. 18F-Sodium Fluoride is valuable for detection of osseous metastases. 18F-fluoroestradiol is now FDA-approved with multiple appropriate clinical uses. There are multiple PET radiotracers in clinical trials, which may add utility of PET imaging for patients with breast cancer in the future. This article will describe the advances during the last quarter century in PET for patients with breast cancer.
Collapse
Affiliation(s)
- Gary A Ulaner
- Molecular Imaging and Therapy, Hoag Family Cancer Institute, Irvine, CA, USA; Departments of Radiology and Translational Genomics, University of Southern California, Los Angeles, CA, USA.
| | - Sofia Carrilho Vaz
- Nuclear Medicine-Radiopharmacology, Champalimaud Clinical Center, Champalimaud Foundation, Lisbon, Portugal; Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - David Groheux
- Nuclear Department of Nuclear Medicine, Saint-Louis Hospital, Paris, France; Centre d'Imagerie Radio-Isotopique (CIRI), La Rochelle, France; University Paris-Diderot, INSERM U976, HIPI, Paris, France
| |
Collapse
|
4
|
Chung HW, Park KS, Lim I, Noh WC, Yoo YB, Nam SE, So Y, Lee EJ. PET/MRI and Novel Targets for Breast Cancer. Biomedicines 2024; 12:172. [PMID: 38255277 PMCID: PMC10813582 DOI: 10.3390/biomedicines12010172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 01/04/2024] [Accepted: 01/09/2024] [Indexed: 01/24/2024] Open
Abstract
Breast cancer, with its global prevalence and impact on women's health, necessitates effective early detection and accurate staging for optimal patient outcomes. Traditional imaging modalities such as mammography, ultrasound, and dynamic contrast-enhanced magnetic resonance imaging (MRI) play crucial roles in local-regional assessment, while bone scintigraphy and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) aid in evaluating distant metastasis. Despite the proven utility of 18F-FDG PET/CT in various cancers, its limitations in breast cancer, such as high false-negative rates for small and low-grade tumors, have driven exploration into novel targets for PET radiotracers, including estrogen receptor, human epidermal growth factor receptor-2, fibroblast activation protein, and hypoxia. The advent of PET/MRI, which combines metabolic PET information with high anatomical detail from MRI, has emerged as a promising tool for breast cancer diagnosis, staging, treatment response assessment, and restaging. Technical advancements including the integration of PET and MRI, considerations in patient preparation, and optimized imaging protocols contribute to the success of dedicated breast and whole-body PET/MRI. This comprehensive review offers the current technical aspects and clinical applications of PET/MRI for breast cancer. Additionally, novel targets in breast cancer for PET radiotracers beyond glucose metabolism are explored.
Collapse
Affiliation(s)
- Hyun Woo Chung
- Department of Nuclear Medicine, Konkuk University Medical Center, Konkuk University School of Medicine, 120-1 Neungdong-ro, Gwangjin-gu, Seoul 05030, Republic of Korea; (H.W.C.); (Y.S.)
| | - Kyoung Sik Park
- Department of Surgery, Konkuk University Medical Center, Konkuk University School of Medicine, 120-1 Neungdong-ro, Gwangjin-gu, Seoul 05030, Republic of Korea; (W.C.N.); (Y.B.Y.); (S.E.N.)
- Research Institute of Medical Science, Konkuk University School of Medicine, 120-1 Neungdong-ro, Gwangjin-gu, Seoul 05030, Republic of Korea
| | - Ilhan Lim
- Department of Nuclear Medicine, Korea Cancer Center Hospital, Korea Institute of Radiological and Medical Sciences (KIRAMS), 75 Nowon-ro, Nowon-gu, Seoul 07812, Republic of Korea;
| | - Woo Chul Noh
- Department of Surgery, Konkuk University Medical Center, Konkuk University School of Medicine, 120-1 Neungdong-ro, Gwangjin-gu, Seoul 05030, Republic of Korea; (W.C.N.); (Y.B.Y.); (S.E.N.)
| | - Young Bum Yoo
- Department of Surgery, Konkuk University Medical Center, Konkuk University School of Medicine, 120-1 Neungdong-ro, Gwangjin-gu, Seoul 05030, Republic of Korea; (W.C.N.); (Y.B.Y.); (S.E.N.)
| | - Sang Eun Nam
- Department of Surgery, Konkuk University Medical Center, Konkuk University School of Medicine, 120-1 Neungdong-ro, Gwangjin-gu, Seoul 05030, Republic of Korea; (W.C.N.); (Y.B.Y.); (S.E.N.)
| | - Young So
- Department of Nuclear Medicine, Konkuk University Medical Center, Konkuk University School of Medicine, 120-1 Neungdong-ro, Gwangjin-gu, Seoul 05030, Republic of Korea; (H.W.C.); (Y.S.)
| | - Eun Jeong Lee
- Department of Nuclear Medicine, Seoul Medical Center, 156 Sinnae-ro, Jungnang-gu, Seoul 02053, Republic of Korea;
| |
Collapse
|
5
|
Alves VDPV, Ata NA, MacLean J, Sharp SE, Li Y, Brady S, Trout AT. Reduced count pediatric whole-body 18F-FDG PET imaging reconstruction with a Bayesian penalized likelihood algorithm. Pediatr Radiol 2024; 54:170-180. [PMID: 37962603 DOI: 10.1007/s00247-023-05801-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 10/24/2023] [Accepted: 10/26/2023] [Indexed: 11/15/2023]
Abstract
BACKGROUND Advanced positron emission tomography (PET) image reconstruction methods promise to allow optimized PET/CT protocols with improved image quality, decreased administered activity and/or acquisition times. OBJECTIVE To evaluate the impact of reducing counts (simulating reduced acquisition time) in block sequential regularized expectation maximization (BSREM) reconstructed pediatric whole-body 18F-fluorodeoxyglucose (FDG) PET images, and to compare BSERM with ordered-subset expectation maximization (OSEM) reconstructed reduced-count images. MATERIALS AND METHODS Twenty children (16 male) underwent clinical whole-body 18F-FDG PET/CT examinations using a 25-cm axial field-of-view (FOV) digital PET/CT system at 90 s per bed (s/bed) with BSREM reconstruction (β=700). Reduced count simulations with varied BSREM β levels were generated from list-mode data: 60 s/bed, β=800; 50 s/bed, β=900; 40 s/bed, β=1000; and 30 s/bed, β=1300. In addition, a single OSEM reconstruction was created at 60 s/bed based on prior literature. Qualitative (Likert scores) and quantitative (standardized uptake value [SUV]) analyses were performed to evaluate image quality and quantitation across simulated reconstructions. RESULTS The mean patient age was 9.0 ± 5.5 (SD) years, mean weight was 38.5 ± 24.5 kg, and mean administered 18F-FDG activity was 4.5 ± 0.7 (SD) MBq/kg. Between BSREM reconstructions, no qualitative measure showed a significant difference versus the 90 s/bed β=700 standard (all P>0.05). SUVmax values for lesions were significantly lower from 90 s/bed, β=700 only at a simulated acquisition time of 30 s/bed, β=1300 (P=0.001). In a side-by-side comparison of BSREM versus OSEM reconstructions, 40 s/bed, β=1000 images were generally preferred over 60 s/bed TOF OSEM images. CONCLUSION In children who undergo whole-body 18F-FDG PET/CT on a 25-cm FOV digital PET/CT scanner, reductions in acquisition time or, by corollary, administered radiopharmaceutical activity of >50% from a clinical standard of 90 s/bed may be possible while maintaining diagnostic quality when a BSREM reconstruction algorithm is used.
Collapse
Affiliation(s)
- Vinicius de Padua V Alves
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA
| | - Nadeen Abu Ata
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Joseph MacLean
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA
| | - Susan E Sharp
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Yinan Li
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Samuel Brady
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Andrew T Trout
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA.
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
| |
Collapse
|
6
|
Makita K, Hamamoto Y, Kanzaki H, Nagasaki K, Miyagawa M, Kawaguchi N, Okada T, Kido T, Kozuki T. Impact of digital positron emission tomography/computed tomography on the delineation of clinical target volume in advanced lung cancer. Mol Clin Oncol 2023; 19:102. [PMID: 38022846 PMCID: PMC10666076 DOI: 10.3892/mco.2023.2698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Accepted: 10/27/2023] [Indexed: 12/01/2023] Open
Abstract
The present study investigated the differences between digital [18F]-Fluorodeoxyglucose (FDG) positron emission tomography [PET]/computed tomography [CT] (dPET/CT) and conventional PET/CT (cPET/CT) in delineating the clinical target volume (CTV) in patients with advanced lung cancer in the involved field radiation therapy (IFRT) era. Patients with advanced lung cancer were scanned using two dual-imaging protocols (dPET/CT and cPET/CT). Two virtual delineations contoured with reference to dPET/CT and cPET/CT images were created for each patient by five radiation oncologists. Changes in the delineation of target volumes in each patient were examined. A total of 10 patients [male/female, 9/1; median age, 65 years (range, 58-80 years)] were enrolled between April 2020 and September 2020. Significant changes in the delineation of CTVs were uncommon between dPET/CT and cPET/CT. A notable increase in CTVn was observed in 10% of the patients (1/10; P<0.05; Smirnov-Grubbs analysis). In this patient, a node that was not assessed as lymph node metastasis when cPET/CT was used was assessed as lymph node metastasis when dPET/CT was used and was included in the CTVn by all five radiation oncologists. In patients with advanced lung cancer, notable changes in CTV delineations are uncommon, regardless of whether dPET/CT or cPET/CT is used. However, in some cases, CTVn delineation with reference to dPET/CT may improve the treatment outcomes of IFRT for advanced lung cancer.
Collapse
Affiliation(s)
- Kenji Makita
- Department of Radiation Oncology, National Hospital Organization Shikoku Cancer Center, Matsuyama, Ehime 791-0280, Japan
- Department of Radiology, Ehime University Graduate School of Medicine, Toon, Ehime 791-0295, Japan
- Department of Radiology, Ehime Prefectural Central Hospital, Matsuyama, Ehime 790-0024, Japan
| | - Yasushi Hamamoto
- Department of Radiation Oncology, National Hospital Organization Shikoku Cancer Center, Matsuyama, Ehime 791-0280, Japan
| | - Hiromitsu Kanzaki
- Department of Radiation Oncology, National Hospital Organization Shikoku Cancer Center, Matsuyama, Ehime 791-0280, Japan
| | - Kei Nagasaki
- Department of Radiation Oncology, National Hospital Organization Shikoku Cancer Center, Matsuyama, Ehime 791-0280, Japan
| | - Masao Miyagawa
- Department of Radiology, Ehime University Graduate School of Medicine, Toon, Ehime 791-0295, Japan
| | - Naoto Kawaguchi
- Department of Radiology, Ehime University Graduate School of Medicine, Toon, Ehime 791-0295, Japan
| | - Tomohisa Okada
- Department of Radiology, Ehime University Graduate School of Medicine, Toon, Ehime 791-0295, Japan
| | - Teruhito Kido
- Department of Radiology, Ehime University Graduate School of Medicine, Toon, Ehime 791-0295, Japan
| | - Toshiyuki Kozuki
- Department of Thoracic Oncology and Medicine, National Hospital Organization Shikoku Cancer Center, Matsuyama, Ehime 791-0280, Japan
| |
Collapse
|
7
|
Ricci M, Carabellese B, Pietroniro D, Grivet Fojaja MR, De Vincentis G, Cimini A. Digital PET for recurrent prostate cancer: how the technology help. Clin Transl Imaging 2023. [DOI: 10.1007/s40336-023-00545-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
|
8
|
Simulated Reduced-Count Whole-Body FDG PET: Evaluation in Children and Young Adults Imaged on a Digital PET Scanner. AJR Am J Roentgenol 2022; 219:952-961. [PMID: 35731102 DOI: 10.2214/ajr.22.27894] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
BACKGROUND. Digital PET scanners with increased sensitivity may allow shorter scan acquisition times or reductions in administered radiopharmaceutical activities. OBJECTIVE. The purpose of this study was to evaluate in children and young adults the impact of shorter simulated acquisition times on the quality of whole-body FDG PET images obtained using a digital PET/CT system. METHODS. This retrospective study included 27 children and young adults (nine male and 18 female patients) who underwent clinically indicated whole-body FDG PET/CT examinations performed using a 25-cm axial FOV PET/CT system at 90 s per bed position (expressed hereafter as seconds per bed). Raw list-mode data were reprocessed to simulate acquisition times of 60, 55, 50, 45, 40, and 30 s/bed. Three radiologists independently reviewed reconstructed images and assigned Likert scores for lesion conspicuity, normal structure conspicuity, image quality, and image noise. A separate observer recorded the SUVmax, SUVmean, and SD of the SUV (SUVSD) for liver, thigh, and the most FDG-avid lesion. The SUVSD/SUVmean (the SUVSD divided by the SUVmean) was calculated as a surrogate of image noise. ANOVA, the Friedman test, and the Dunn test were used to compare qualitative measures (combining reader scores) and SUV measurements. RESULTS. The mean patient age was 10.8 ± 8.3 (SD) years, mean BMI was 18.7 ± 2.9, and mean administered FDG activity was 4.44 ± 0.37 MBq/kg (0.12 ± 0.01 mCi/kg). No qualitative measure showed a significant difference versus 90 s/bed for the simulated acquisition at 60 s/bed (all p > .05). Significant differences (all p < .05) versus 90 s/bed were observed for lesion conspicuity at at most 40 s/bed, conspicuity of normal structures and overall image quality at at most 45 s/bed, and image noise at at most 55 s/bed. SUVmean was not significantly different from 90 s/bed for any site for any reduced-count simulation (all p > .05). SUVSD/SUVmean and SUVmax showed gradual increases with decreasing acquisition times and were significantly different from 90 s/bed only for liver at 60 s/bed (for SUVmax: 1.00 ± 0.00 vs 1.05 ± 0.03, p = .02; for SUVSD/SUVmean: 0.09 ± 0.02 vs 0.11 ± 0.02, p = .04). CONCLUSION. Favorable findings for the simulated acquisition at 60 s/bed suggest that, in children and young adults who undergo imaging performed using a 25-cm FOV digital PET scanner, acquisition time or administered FDG activity may be decreased by approximately 33% from the clinical standard without significantly impacting image quality. CLINICAL IMPACT. A 25-cm axial FOV digital scanner may allow FDG PET/CT examinations to be performed with reduced radiation exposure or faster scan acquisition times.
Collapse
|
9
|
Hicks RJ, Van den Abbeele AD. Will ultra-extended field-of-view scanners be an expensive folly or the next clinical standard for PET/CT? Cancer Imaging 2022; 22:49. [PMID: 36068626 PMCID: PMC9450327 DOI: 10.1186/s40644-022-00486-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Accepted: 08/23/2022] [Indexed: 11/24/2022] Open
Affiliation(s)
| | - Annick D Van den Abbeele
- Dana-Farber Cancer Institute and Mass General Brigham Hospitals, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
10
|
Venet M, Friedberg MK, Mertens L, Baranger J, Jalal Z, Tlili G, Villemain O. Nuclear Imaging in Pediatric Cardiology: Principles and Applications. Front Pediatr 2022; 10:909994. [PMID: 35874576 PMCID: PMC9301385 DOI: 10.3389/fped.2022.909994] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Accepted: 06/16/2022] [Indexed: 11/13/2022] Open
Abstract
Nuclear imaging plays a unique role within diagnostic imaging since it focuses on cellular and molecular processes. Using different radiotracers and detection techniques such as the single photon emission scintigraphy or the positron emission tomography, specific parameters can be assessed: myocardial perfusion and viability, pulmonary perfusion, ventricular function, flow and shunt quantification, and detection of inflammatory processes. In pediatric and congenital cardiology, nuclear imaging can add complementary information compared to other imaging modalities such as echocardiography or magnetic resonance imaging. In this state-of-the-art paper, we appraise the different techniques in pediatric nuclear imaging, evaluate their advantages and disadvantages, and discuss the current clinical applications.
Collapse
Affiliation(s)
- Maelys Venet
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| | - Mark K. Friedberg
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| | - Luc Mertens
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| | - Jerome Baranger
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| | - Zakaria Jalal
- Department of Congenital and Pediatric Cardiology, Hôpital du Haut-Lévêque, CHU de Bordeaux, Bordeaux-Pessac, France
| | - Ghoufrane Tlili
- Department of Nuclear Medicine, Hôpital du Haut-Lévêque, CHU de Bordeaux, Bordeaux-Pessac, France
| | - Olivier Villemain
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
11
|
Long Y, Shao F, Ji H, Song X, Lv X, Xia X, Liu Q, Zhang Y, Zeng D, Lan X, Gai Y. Evaluation of a CD13 and Integrin α vβ 3 Dual-Receptor Targeted Tracer 68Ga-NGR-RGD for Ovarian Tumor Imaging: Comparison With 18F-FDG. Front Oncol 2022; 12:884554. [PMID: 35664759 PMCID: PMC9158524 DOI: 10.3389/fonc.2022.884554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2022] [Accepted: 04/08/2022] [Indexed: 11/13/2022] Open
Abstract
Ovarian cancer has the highest mortality rate of gynecologic malignancy. 18F-FDG positron emission tomography (PET) adds an important superiority over traditional anatomic imaging modalities in oncological imaging but has drawbacks including false negative results at the early stage of ovarian cancer, and false positives when inflammatory comorbidities are present. Aminopeptidase N (APN, also known as CD13) and integrin αvβ3 are two important targets overexpressed on tumor neo-vessels and frequently on ovarian cancerous cells. In this study, we used subcutaneous and metastatic models of ovarian cancer and muscular inflammation models to identify 68Ga-NGR-RGD, a heterodimeric tracer consisting of NGR and RGD peptides targeting CD13 and integrin αvβ3, respectively, and compared it with 18F-FDG. We found that 68Ga-NGR-RGD showed greater contrast in SKOV3 and ES-2 tumors than 18F-FDG. Low accumulation of 68Ga-NGR-RGD but avid uptake of 18F-FDG were observed in inflammatory muscle. In abdominal metastasis models, PET imaging with 68Ga-NGR-RGD allowed for rapid and clear delineation of both peritoneal and liver metastases (3-6 mm), whereas, 18F-FDG could not distinguish the metastasis lesions due to the relatively low metabolic activity in tumors and the interference of intestinal physiological 18F-FDG uptake. Due to the high tumor-targeting efficacy, low inflammatory uptake, and higher tumor-to-background ratios compared to that of 18F-FDG, 68Ga-NGR-RGD presents a promising imaging agent for diagnosis, staging, and follow-up of ovarian tumors.
Collapse
Affiliation(s)
- Yu Long
- Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Fuqiang Shao
- Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Hao Ji
- Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Xiangming Song
- Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Xiaoying Lv
- Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Xiaotian Xia
- Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Qingyao Liu
- Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Yongxue Zhang
- Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Dexing Zeng
- Department of Radiology, University of Pittsburgh, Pittsburgh, PA, United States
| | - Xiaoli Lan
- Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| | - Yongkang Gai
- Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China
| |
Collapse
|
12
|
Artificial intelligence-based PET denoising could allow a two-fold reduction in [ 18F]FDG PET acquisition time in digital PET/CT. Eur J Nucl Med Mol Imaging 2022; 49:3750-3760. [PMID: 35593925 PMCID: PMC9399218 DOI: 10.1007/s00259-022-05800-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Accepted: 04/10/2022] [Indexed: 11/18/2022]
Abstract
Purpose We investigated whether artificial intelligence (AI)-based denoising halves PET acquisition time in digital PET/CT. Methods One hundred ninety-five patients referred for [18F]FDG PET/CT were prospectively included. Body PET acquisitions were performed in list mode. Original “PET90” (90 s/bed position) was compared to reconstructed ½-duration PET (45 s/bed position) with and without AI-denoising, “PET45AI and PET45”. Denoising was performed by SubtlePET™ using deep convolutional neural networks. Visual global image quality (IQ) 3-point scores and lesion detectability were evaluated. Lesion maximal and peak standardized uptake values using lean body mass (SULmax and SULpeak), metabolic volumes (MV), and liver SULmean were measured, including both standard and EARL1 (European Association of Nuclear Medicine Research Ltd) compliant SUL. Lesion-to-liver SUL ratios (LLR) and liver coefficients of variation (CVliv) were calculated. Results PET45 showed mediocre IQ (scored poor in 8% and moderate in 68%) and lesion concordance rate with PET90 (88.7%). In PET45AI, IQ scores were similar to PET90 (P = 0.80), good in 92% and moderate in 8% for both. The lesion concordance rate between PET90 and PET45AI was 836/856 (97.7%), with 7 lesions (0.8%) only detected in PET90 and 13 (1.5%) exclusively in PET45AI. Lesion EARL1 SULpeak was not significantly different between both PET (P = 0.09). Lesion standard SULpeak, standard and EARL1 SULmax, LLR and CVliv were lower in PET45AI than in PET90 (P < 0.0001), while lesion MV and liver SULmean were higher (P < 0.0001). Good to excellent intraclass correlation coefficients (ICC) between PET90 and PET45AI were observed for lesion SUL and MV (ICC ≥ 0.97) and for liver SULmean (ICC ≥ 0.87). Conclusion AI allows [18F]FDG PET duration in digital PET/CT to be halved, while restoring degraded ½-duration PET image quality. Future multicentric studies, including other PET radiopharmaceuticals, are warranted. Supplementary Information The online version contains supplementary material available at 10.1007/s00259-022-05800-1.
Collapse
|
13
|
Bouchelouche K, Sathekge MM. Letter from the Editors. Semin Nucl Med 2022; 52:263-265. [DOI: 10.1053/j.semnuclmed.2022.03.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|