Li N, Cai QM, Hu NY, Jiang SL, Chen FQ, Hu QQ, Yang F, He CZ. Pyrosequencing analysis of bacterial community changes in dental unit waterlines after chlorogenic acid treatment. Front Cell Infect Microbiol 2024; 14:1303099. [PMID: 38299116 PMCID: PMC10828043 DOI: 10.3389/fcimb.2024.1303099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Accepted: 01/02/2024] [Indexed: 02/02/2024] Open
Abstract
Introduction The contamination of dental unit waterlines (DUWLs) poses a significant risk of cross-infection in dentistry. Although chemical disinfectants have been effective in reducing number of bacteria, they do have limitations. Methods This study aimed to investigate the potential of chlorogenic acid, a natural substance with broadspectrum antibacterial properties, for treating DUWLs. Over a period of three months, we analyzed the microbial communities in 149 DUWLs samples collected from 5 dental units using high-throughput pyrophosphate sequencing. Results The results revealed that chlorogenic acid treatment had a significant impact on the microbial community profile in the DUWLs, with the most significant changes occurring within the first 15 days and stabilization observed in the last 30 days. The predominant genera detected in the samples were Bacteroides, Lactobacillus, Streptococcus, Methylobacterium, and Phreatobacter. Additionally, the relative abundance of certain beneficial bacteria, such as Alloprevotella, Roseburia, and Blautia, increased, while the presence of opportunistic pathogens like Mycobacteria significantly decreased. The functional prediction analysis using the KEGG database indicated a decrease in the pathogenicity of the bacterial community in the DUWLs following chlorogenic acid treatment. Discussion This study introduces a novel approach for the prevention and treatment of infections associated with dental care.
Collapse
Affiliation(s)
- Na Li
- Department of Stomatology, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China
- Nursing School, Nanchang University, Nanchang, China
| | - Qin-Ming Cai
- The First Affiliated Hospital of Nanchang University, School of Public Health, Nanchang University, Nanchang, China
- The Second School of Clinical Medicine, Southern Medical University, Guangzhou, China
| | - Ni-Ya Hu
- The First Affiliated Hospital of Nanchang University, School of Public Health, Nanchang University, Nanchang, China
| | - Shu-ling Jiang
- Department of Stomatology, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China
- Nursing School, Nanchang University, Nanchang, China
| | - Fu-Qing Chen
- Department of Stomatology, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China
| | - Qiao-Qiao Hu
- Department of Stomatology, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China
| | - Fen Yang
- Department of Stomatology, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China
| | - Chao-Zhu He
- Nursing School, Nanchang University, Nanchang, China
| |
Collapse
|
2
|
Buitrago JM, Kolbe RJ, Siqueira MF. Dental unit waterline testing practices: an 11-Year retrospective study. BMC Oral Health 2023; 23:867. [PMID: 37968643 PMCID: PMC10652605 DOI: 10.1186/s12903-023-03590-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Accepted: 10/27/2023] [Indexed: 11/17/2023] Open
Abstract
OBJECTIVES This retrospective study examined the dental unit waterline (DUWL) testing practices of Saskatchewan dental clinics over a period of 11 years, with an emphasis on their responses after identification of high microbial levels. MATERIALS AND METHODS Dental clinics (n = 137) aseptically collected samples of output water from their air/water syringes, handpieces, and ultrasonic scaler lines using Sigma-Aldrich® waterline test kits and delivered them to a quality assurance laboratory. Tests were incubated for seven days at room temperature, and those with heterotrophic plate counts > 500 CFU/mL were reported as failures. Statistical analyses were performed on a database containing 4,093 test results. RESULTS Participating clinics submitted an average of 11 DUWL tests per year. Overall, 21% of tests failed, and a moderate positive association (rs=.52, p < 0.001) was found between clinics' DUWL testing frequency and failure rate. Only 7% of failed DUWL tests were followed up by collection of a subsequent test within two weeks, of which 47% still exceeded the 500 CFU/mL threshold. CONCLUSIONS Our findings demonstrate an association between DUWL testing frequency and detection of unacceptable microbial levels, along with infrequent retesting and often-inadequate intervention after a failed test. This suggests the need for further efforts at the regulatory and educational levels to maintain adequate water quality during dental treatment. CLINICAL RELEVANCE Procedural water can become contaminated in DUWLs and endanger patients. Regular DUWL monitoring and evidence-based interventions to treat contaminated systems are necessary to safeguard patient health.
Collapse
Affiliation(s)
- Juan M Buitrago
- College of Dentistry, University of Saskatchewan, Saskatoon, SK, Canada
| | - Rob J Kolbe
- College of Dentistry, University of Saskatchewan, Saskatoon, SK, Canada
| | | |
Collapse
|
3
|
Marino F, Mazzotta M, Pascale MR, Derelitto C, Girolamini L, Cristino S. First water safety plan approach applied to a Dental Clinic complex: identification of new risk factors associated with Legionella and P. aeruginosa contamination, using a novel sampling, maintenance and management program. J Oral Microbiol 2023; 15:2223477. [PMID: 37346998 PMCID: PMC10281406 DOI: 10.1080/20002297.2023.2223477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 05/18/2023] [Accepted: 06/06/2023] [Indexed: 06/23/2023] Open
Abstract
Dental unit waterlines (DUWLs) represent a complex environment able to promote microbial contamination, due to functional, mechanical and practical risk factors. According to a water safety plan approach, the main goal is to preserve the health of dentists, dental staff and patients. The aim of this study is to develop a DUWLs water safety plan that is able to support correct and effective maintenance and disinfection procedures. Three different water systems serve 60 dental chairs: (i) water that comes directly from municipal water (Type A), (ii) water supplied by municipal water and water bottles (Type B) and (iii) water supplied only via water bottles (Type C). For each type, Legionella and Pseudomonas aeruginosa contamination was studied, by applying a new sampling scheme, based on separate sampling from water bottles, cup filler and handpieces. Type B DUWL is the only type of DUWL contaminated by L. pneumophila (ST 59) and L. anisa (mean contamination: 608.33 ± 253.33 cfu/L) detected in cup filler and handpieces, as well as the high presence of P. aeruginosa (44.42 ± 13.25 cfu/100 mL). Two subsequent shock treatments and resampling procedures were performed by increasing disinfectant dosage and contact time and removing some DUWL components linked to biofilm growth in DUWLs. A significant reduction of contamination was obtained for both microorganisms (Legionella spp.: -100%, p < 0.001 and P. aeruginosa: -99.86%, p = 0.006). The sampling strategy proposed allows us to identify the source of contamination and better focus on the maintenance and disinfection procedures. DUWLs represent an environment that requires a multidisciplinary approach, combining the knowledge of all DUWL components to correct procedures that are able to preserve the health of personnel and patients, as well as guaranteeing DUWLs' safe functionality.
Collapse
Affiliation(s)
- Federica Marino
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
| | - Marta Mazzotta
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
| | - Maria Rosaria Pascale
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
- Department of Civil, Chemical, Environmental and Materials Engineering, University of Bologna, Bologna, Italy
| | - Carlo Derelitto
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
| | - Luna Girolamini
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
- European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Legionella Infections (ESGLI), Basel, Switzerland
| | - Sandra Cristino
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
- European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Legionella Infections (ESGLI), Basel, Switzerland
| |
Collapse
|
4
|
Sun X, Li Y, Yang Q, Zhang H, Xu N, Tang Z, Wu S, Jiang Y, Mohamed HF, Ou D, Zheng X. Identification of quorum sensing-regulated Vibrio fortis as potential pathogenic bacteria for coral bleaching and the effects on the microbial shift. Front Microbiol 2023; 14:1116737. [PMID: 36819038 PMCID: PMC9935839 DOI: 10.3389/fmicb.2023.1116737] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Accepted: 01/09/2023] [Indexed: 02/05/2023] Open
Abstract
Coastal pollution, global warming, ocean acidification, and other reasons lead to the imbalance of the coral reef ecosystem, resulting in the increasingly serious problem of coral degradation. Coral bleaching is often accompanied by structural abnormalities of coral symbiotic microbiota, among which Vibrio is highly concerned. In this study, Vibrio fortis S10-1 (MCCC 1H00104), isolated from sea cucumber, was used for the bacterial infection on coral Seriatopora guttatus and Pocillopora damicornis. The infection of S10-1 led to coral bleaching and a significant reduction of photosynthetic function in coral holobiont, and the pathogenicity of V. fortis was regulated by quorum sensing. Meanwhile, Vibrio infection also caused a shift of coral symbiotic microbial community, with significantly increased abundant Proteobacteria and Actinobacteria and significantly reduced abundant Firmicutes; on genus level, the abundance of Bacillus decreased significantly and the abundance of Rhodococcus, Ralstonia, and Burkholderia-Caballeronia-Paraburkholderia increased significantly; S10-1 infection also significantly impacted the water quality in the micro-ecosystem. In contrast, S10-1 infection showed less effect on the microbial community of the live stone, which reflected that the microbes in the epiphytic environment of the live stone might have a stronger ability of self-regulation; the algal symbionts mainly consisted of Cladocopium sp. and showed no significant effect by the Vibrio infection. This study verified that V. fortis is the primary pathogenic bacterium causing coral bleaching, revealed changes in the microbial community caused by its infection, provided strong evidence for the "bacterial bleaching" hypothesis, and provided an experimental experience for the exploration of the interaction mechanism among microbial communities, especially coral-associated Vibrio in the coral ecosystem, and potential probiotic strategy or QS regulation on further coral disease control.
Collapse
Affiliation(s)
- Xiaohui Sun
- College of Chemical Engineering, Huaqiao University, Xiamen, China,*Correspondence: Xiaohui Sun,
| | - Yan Li
- Third Institute of Oceanography, Ministry of Natural Resources, Xiamen, China
| | - Qian Yang
- College of Chemical Engineering, Huaqiao University, Xiamen, China
| | - Han Zhang
- Third Institute of Oceanography, Ministry of Natural Resources, Xiamen, China
| | - Nuo Xu
- College of Chemical Engineering, Huaqiao University, Xiamen, China
| | - Zheng Tang
- College of Chemical Engineering, Huaqiao University, Xiamen, China
| | - Shishi Wu
- College of Chemical Engineering, Huaqiao University, Xiamen, China
| | - Yusheng Jiang
- College of Chemical Engineering, Huaqiao University, Xiamen, China
| | - Hala F. Mohamed
- Third Institute of Oceanography, Ministry of Natural Resources, Xiamen, China,Botany and Microbiology Department (Girls Branch), Faculty of Science, Al-Azhar University, Cairo, Egypt
| | - Danyun Ou
- Third Institute of Oceanography, Ministry of Natural Resources, Xiamen, China,Key Laboratory of Marine Ecological Conservation and Restoration, Ministry of Natural Resources, Xiamen, China,Danyun Ou,
| | - Xinqing Zheng
- Third Institute of Oceanography, Ministry of Natural Resources, Xiamen, China,Key Laboratory of Marine Ecological Conservation and Restoration, Ministry of Natural Resources, Xiamen, China,Observation and Research Station of Coastal Wetland Ecosystem in Beibu Gulf, Ministry of Natural Resources, Xiamen, China,Xinqing Zheng,
| |
Collapse
|
5
|
Wu M, Shi Z, Yu X, Xu Y, Jin X, Zhang L, Fu B. Disinfection methods of dental unit waterlines contamination: a systematic review. J Med Microbiol 2022; 71. [PMID: 35670283 DOI: 10.1099/jmm.0.001540] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Background. Severe contamination of dental unit waterlines was found in healthcare settings. The benefits of decontamination methods are controversial. The aim of this review was to systematically evaluate disinfection methods in contamination control of dental unit waterlines.Methods. The terms 'dental unit waterline(s) or DUWL(s) or dental unit water line(s)' were searched through PubMed, Cochrane Library, Embase, Web of Science and Scopusup to 31 May 2021. The DUWLs' output water was incubated on R2A agar at 20-28 °C for 5-7 days to evaluate heterotrophic mesophilic bacteria. The risk of bias was evaluated by a modified Newcastle-Ottawa quality assessment scale.Results. Eighteen papers from the literature were included. One study indicated that water supply played a crucial role in disinfecting DUWLs. Three studies indicated that flushing decreased bacteria counts but did not meet the American CDC standard (500 c.f.u. ml-1). All chlorine- and peroxide-containing disinfectants except sodium hypochlorite in one of 15 studies as well as three mouthrinses and citrus botanical extract achieved the standard (≤500 c.f.u. ml-1). The included studies were of low (1/18), moderate (6/18) and high (11/18) quality.Conclusion. Independent water reservoirs are recommended for disinfecting DUWLs using distilled water. Flushing DUWLs should be combined with disinfections. Nearly all the chlorine-, chlorhexidine- and peroxide-containing disinfectants, mouthrinses and citrus botanical extract meet the standard for disinfecting DUWLs. Alkaline peroxide would lead to tube blockage in the DUWLs. Regularly changing disinfectants can reduce the risk of occurrence of disinfectant-resistant strains of microbes.
Collapse
Affiliation(s)
- Mengting Wu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006, PR China
| | - Zhiwei Shi
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006, PR China
| | - Xuefen Yu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006, PR China
| | - Yuedan Xu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006, PR China
| | - Xinyang Jin
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006, PR China
| | - Ling Zhang
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006, PR China
| | - Baiping Fu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006, PR China
| |
Collapse
|
6
|
Walczak M, Michalska-Sionkowska M, Olkiewicz D, Tarnawska P, Warżyńska O. Potential of Carvacrol and Thymol in Reducing Biofilm Formation on Technical Surfaces. Molecules 2021; 26:molecules26092723. [PMID: 34066411 PMCID: PMC8125478 DOI: 10.3390/molecules26092723] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 05/01/2021] [Accepted: 05/02/2021] [Indexed: 01/18/2023] Open
Abstract
Polyvinyl chloride (PVC), polypropylene (PP), polyethylene (PE), and stainless steel (SS) are commonly used in medicine and food production technologies. During contact with microorganisms on the surface of these materials, a microbial biofilm is formed. The biofilm structure is difficult to remove and promotes the development of pathogenic bacteria. For this reason, the inhibition of biofilm formation in medical and food production environments is very important. For this purpose, five naturally occurring compounds were used for antimicrobial screening tests. The two with the best antimicrobial properties were chosen to inhibit the biofilm formation of Staphylococcus aureus and Pseudomonas aeruginosa. After 3 days of exposure, thymol reduced the amount of biofilm of Pseudomonas aeruginosa within the range of 70–77% and 52–75% for Staphylococcus aureus. Carvacrol inhibited the formation of biofilms by up to 74–88% for Pseudomonas aeruginosa and up to 86–100% for Staphylococcus aureus. Those phenols decreased the enzyme activity of the biofilm by up to 40–100%. After 10 days of exposure to thymol, biofilm formation was reduced by 80–100% for Pseudomonas aeruginosa and by about 79–100% for Staphylococcus aureus. Carvacrol reduced the amount of biofilm by up to 91–100% for Pseudomonas aeruginosa and up to 95–100% for Staphylococcus aureus.
Collapse
|
7
|
Cheng L, Naibijiang N, Hasenbai A, Dong H, He H. Bacteriostatic effects of nanometer silver disinfectant on the biofilms in dental unit water lines. J Dent Sci 2020; 16:327-332. [PMID: 33384816 PMCID: PMC7770243 DOI: 10.1016/j.jds.2020.03.015] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Revised: 03/30/2020] [Indexed: 01/10/2023] Open
Abstract
Background/purpose Dental unit water lines (DUWLs) may be contaminated by aerobic bacteria in clinical settings and comprehensive disinfecting methods should be considered without delay. Herein, this study aims to investigate the timeliness and dynamic bacteriostatic effects of different forms of nanometer silver (NMS) disinfectant on bio-film in DUWLs. Materials and methods Bacterial DUWLs samples were respectively treated with different NMS forms, including liquid phase and solid phase at the concentrations of 0.25%, 0.5%, 1% and 2% and their bacteriostatic effects were observed at the 1st, 4th, 7th, 14th, 28th day. Results The bacteriostatic effects of liquid phase NMS at all concentrations were unsatisfactory and the bacteriostatic rate was only 20% at the 1st day. However, there appeared massive bacteria growth at the 4th, 7th, 14th, 28th day. Comparatively, no bacteria growth was found at the 1st, 4th, 7th, 14th, 28th day after sterilizing with different concentrations of solid phase NMS and the bacteriostatic rate was 100%. Conclusion Microbial contamination in DUWLs can be disinfected by different NMS forms, among which solid phase NMS is more bactericidal against bacteria bio-films, demonstrating significant roles of solid phase NMS in preventing DUWL contamination.
Collapse
Affiliation(s)
- Lujin Cheng
- Department of Stomatology, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang Uyghur Autonomous Region, People's Republic of China
| | - Nijiatijiang Naibijiang
- Urumqi Stomatology Hospital, Urumqi, Xinjiang Uyghur Autonomous Region, People's Republic of China
| | - Aletengguli Hasenbai
- Department of Stomatology, The People's Hospital of Guoerguosi, Guoerguosi, Xinjiang Uyghur Autonomous Region, People's Republic of China
| | - Hongbin Dong
- Department of Stomatology, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang Uyghur Autonomous Region, People's Republic of China
| | - Huiyu He
- Department of Stomatology, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang Uyghur Autonomous Region, People's Republic of China
| |
Collapse
|
8
|
Lizzadro J, Mazzotta M, Girolamini L, Dormi A, Pellati T, Cristino S. Comparison between Two Types of Dental Unit Waterlines: How Evaluation of Microbiological Contamination Can Support Risk Containment. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:E328. [PMID: 30682855 PMCID: PMC6388184 DOI: 10.3390/ijerph16030328] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/10/2018] [Revised: 01/16/2019] [Accepted: 01/18/2019] [Indexed: 01/16/2023]
Abstract
Infection risk management in a dental unit waterline (DUWL) involves healthcare personnel and patients and is related to routine exposure to water and aerosols that may contain bacterial species. To improve water safety plans, maintenance, and sanitation procedures, analyses of heterotrophic plate counts (HPCs) at 36 °C, and two other microorganisms frequently associated with biofilms, Pseudomonas aeruginosa and Legionella spp., were performed in order to evaluate differences in microbiological contamination between two types of DUWLs: Type A, provided by a water tank, and Type B, directly connected to municipal water. The data showed that the water supply and water safety plan differentially influenced microbiological contamination: Type A DUWLs were more contaminated than Type B DUWLs for all microbiological parameters tested, with significant changes in the percentage of positive samples and contamination levels that were beyond the limits of standard guidelines. The results obtained show how the storage tank, the absence of anti-retraction valves, and the disinfection procedures performed are the main critical points of Type A DUWLs, which confirms that dental unit management (maintenance/sanitization) is often missed or not correctly applied by stakeholders, with an underestimation of the real risk of infection for patients and operators.
Collapse
Affiliation(s)
- Jessica Lizzadro
- Department of Biological, Geological, and Environmental Sciences, BiGeA, University of Bologna, via San Giacomo 12, 40126 Bologna, Italy.
| | - Marta Mazzotta
- Department of Biological, Geological, and Environmental Sciences, BiGeA, University of Bologna, via San Giacomo 12, 40126 Bologna, Italy.
| | - Luna Girolamini
- Department of Biological, Geological, and Environmental Sciences, BiGeA, University of Bologna, via San Giacomo 12, 40126 Bologna, Italy.
| | - Ada Dormi
- Department of Medical and Surgical Science, DIMEC, University of Bologna, via San Giacomo 12, 40126 Bologna, Italy.
| | - Tiziana Pellati
- GVM Care & Research, via Emaldi 10, 48124 Lugo di Ravenna, Italy.
| | - Sandra Cristino
- Department of Biological, Geological, and Environmental Sciences, BiGeA, University of Bologna, via San Giacomo 12, 40126 Bologna, Italy.
| |
Collapse
|
9
|
Ditommaso S, Giacomuzzi M, Ricciardi E, Garbuio R, Zotti CM. The role of chemical products at low doses in preventing the proliferation of bacteria in dental unit waterlines: the ICX ® experience. JOURNAL OF WATER AND HEALTH 2018; 16:150-158. [PMID: 29424728 DOI: 10.2166/wh.2017.035] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
In this study we evaluated (1) the efficacy of a protocol that combines hydrogen peroxide (shock treatment) and ICX® tablets (continuous treatment) for the control of microbial contamination in dental unit water lines, and (2) the in vitro antimicrobial activity of ICX® tablets on collection and wild strains isolated from dental chair output waters. To assess the treatment effectiveness, the microbial load in the output water samples of three dental chairs were investigated: one control chair received only shock treatment. In vitro bactericidal activity was tested against Staphylococcus aureus and Pseudomonas aeruginosa. Data obtained from samples collected from chairs treated with ICX® and shock treatment and data from the control chair did not differ significantly on the basis of microbial load. In the in vitro study, the product was unable to kill Gram-negative bacteria. These results show that the continuous introduction of ICX® was not effective in maintaining low counts of the heterotrophic bacteria in the output water of dental devices, and shock treatment may be needed more frequently than monthly.
Collapse
Affiliation(s)
- Savina Ditommaso
- Department of Public Health and Pediatrics, University of Turin, Piazza Polonia 94, 10126 Turin, Italy E-mail:
| | - Monica Giacomuzzi
- Department of Public Health and Pediatrics, University of Turin, Piazza Polonia 94, 10126 Turin, Italy E-mail:
| | - Elisa Ricciardi
- Department of Public Health and Pediatrics, University of Turin, Piazza Polonia 94, 10126 Turin, Italy E-mail:
| | - Roberto Garbuio
- Freelance Dentist, Piazza Campidoglio 2, 10036 Settimo Torinese, Italy
| | - Carla M Zotti
- Department of Public Health and Pediatrics, University of Turin, Piazza Polonia 94, 10126 Turin, Italy E-mail:
| |
Collapse
|
10
|
Zhang Y, Ping Y, Zhou R, Wang J, Zhang G. High throughput sequencing-based analysis of microbial diversity in dental unit waterlines supports the importance of providing safe water for clinical use. J Infect Public Health 2017; 11:357-363. [PMID: 28988812 DOI: 10.1016/j.jiph.2017.09.017] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2017] [Revised: 09/02/2017] [Accepted: 09/09/2017] [Indexed: 01/27/2023] Open
Abstract
This study aims to explore the water quality of dental unit waterlines (DUWLs) and the diversity of microbial communities in DUWLs. Water samples from 33 dental chair units (DCUs) were collected, diluted and then spread on sterilized R2A plate for incubation. Subsequently, the microbial colony-forming units per milliliter (CFU/ml) were recorded by an automatic colony analyzer. Total DNA extracted from the rest of the samples was tested on the Illumina MiSeq PE300 platform. T-test and Kruskal-Wallis rank test were adopted for statistical analysis. Significance was assumed at a P<0.05. After incubation, the average total microbial count was 21,413.13±17,861.00CFU/ml. High-throughput sequencing revealed 10 bacterial phyla, including 9 identified and 1 unclassified phyla. Totally 63 sequences were identified at the genus level, including 42 genera, 3 tentative species and 18 unclassified genera. In addition, 7 potential human pathogenic bacteria were detected. In summary, department, brand and service life of DCUs do not influence the water quality of DUWLs significantly. The diversity of microbial communities in DUWLs is abundant and includes both pathogenic and some unknown bacteria.
Collapse
Affiliation(s)
- Yuan Zhang
- Jiangsu Key Laboratory of Oral Diseases, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Yifan Ping
- Jiangsu Key Laboratory of Oral Diseases, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Ruyu Zhou
- Jiangsu Key Laboratory of Oral Diseases, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Juan Wang
- Jiangsu Key Laboratory of Oral Diseases, Nanjing Medical University, Department of Endodontics and Operative Dentistry, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, Jiangsu, China.
| | - Guangdong Zhang
- Jiangsu Key Laboratory of Oral Diseases, Nanjing Medical University, Department of Endodontics and Operative Dentistry, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, Jiangsu, China.
| |
Collapse
|
11
|
Zemouri C, de Soet H, Crielaard W, Laheij A. A scoping review on bio-aerosols in healthcare and the dental environment. PLoS One 2017; 12:e0178007. [PMID: 28531183 PMCID: PMC5439730 DOI: 10.1371/journal.pone.0178007] [Citation(s) in RCA: 170] [Impact Index Per Article: 24.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Accepted: 05/06/2017] [Indexed: 01/16/2023] Open
Abstract
Background Bio-aerosols originate from different sources and their potentially pathogenic nature may form a hazard to healthcare workers and patients. So far no extensive review on existing evidence regarding bio-aerosols is available. Objectives This study aimed to review evidence on bio-aerosols in healthcare and the dental setting. The objectives were 1) What are the sources that generate bio-aerosols?; 2) What is the microbial load and composition of bio-aerosols and how were they measured?; and 3) What is the hazard posed by pathogenic micro-organisms transported via the aerosol route of transmission? Methods Systematic scoping review design. Searched in PubMed and EMBASE from inception to 09-03-2016. References were screened and selected based on abstract and full text according to eligibility criteria. Full text articles were assessed for inclusion and summarized. The results are presented in three separate objectives and summarized for an overview of evidence. Results The search yielded 5,823 studies, of which 62 were included. Dental hand pieces were found to generate aerosols in the dental settings. Another 30 sources from human activities, interventions and daily cleaning performances in the hospital also generate aerosols. Fifty-five bacterial species, 45 fungi genera and ten viruses were identified in a hospital setting and 16 bacterial and 23 fungal species in the dental environment. Patients with certain risk factors had a higher chance to acquire Legionella in hospitals. Such infections can lead to irreversible septic shock and death. Only a few studies found that bio-aerosol generating procedures resulted in transmission of infectious diseases or allergic reactions. Conclusion Bio-aerosols are generated via multiple sources such as different interventions, instruments and human activity. Bio-aerosols compositions reported are heterogeneous in their microbiological composition dependent on the setting and methodology. Legionella species were found to be a bio-aerosol dependent hazard to elderly and patients with respiratory complaints. But all aerosols can be can be hazardous to both patients and healthcare workers.
Collapse
Affiliation(s)
- Charifa Zemouri
- Department of Preventive Dentistry, Academic Centre for Dentistry Amsterdam, University of Amsterdam & Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- * E-mail:
| | - Hans de Soet
- Department of Preventive Dentistry, Academic Centre for Dentistry Amsterdam, University of Amsterdam & Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Wim Crielaard
- Department of Preventive Dentistry, Academic Centre for Dentistry Amsterdam, University of Amsterdam & Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Alexa Laheij
- Department of Preventive Dentistry, Academic Centre for Dentistry Amsterdam, University of Amsterdam & Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
12
|
Boyle MA, O'Donnell MJ, Russell RJ, Galvin N, Swan J, Coleman DC. Overcoming the problem of residual microbial contamination in dental suction units left by conventional disinfection using novel single component suction handpieces in combination with automated flood disinfection. J Dent 2015; 43:1268-79. [PMID: 26248229 DOI: 10.1016/j.jdent.2015.07.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2015] [Revised: 07/30/2015] [Accepted: 07/31/2015] [Indexed: 01/28/2023] Open
Abstract
OBJECTIVES Decontaminating dental chair unit (DCU) suction systems in a convenient, safe and effective manner is problematic. This study aimed to identify and quantify the extent of the problems using 25 DCUs, methodically eliminate these problems and develop an efficient approach for reliable, effective, automated disinfection. METHODS DCU suction system residual contamination by environmental and human-derived bacteria was evaluated by microbiological culture following standard aspiration disinfection with a quaternary ammonium disinfectant or alternatively, a novel flooding approach to disinfection. Disinfection of multicomponent suction handpieces, assembled and disassembled, was also studied. A prototype manual and a novel automated Suction Tube Cleaning System (STCS) were developed and tested, as were novel single component suction handpieces. RESULTS Standard aspiration disinfection consistently failed to decontaminate DCU suction systems effectively. Semi-confluent bacterial growth (101-500 colony forming units (CFU) per culture plate) was recovered from up to 60% of suction filter housings and from up to 19% of high and 37% of low volume suction hoses. Manual and automated flood disinfection of DCU suction systems reduced this dramatically (ranges for filter cage and high and low volume hoses of 0-22, 0-16 and 0-14CFU/plate, respectively) (P<0.0001). Multicomponent suction handpieces could not be adequately disinfected without prior removal and disassembly. Novel single component handpieces, allowed their effective disinfection in situ using the STCS, which virtually eliminated contamination from the entire suction system. CONCLUSION Flood disinfection of DCU suction systems and single component handpieces radically improves disinfection efficacy and considerably reduces potential cross-infection and cross-contamination risks. CLINICAL SIGNIFICANCE DCU suction systems become heavily contaminated during use. Conventional disinfection does not adequately control this. Furthermore, multicomponent suction handpieces cannot be adequately disinfected without disassembly, which is costly in time, staff and resources. The automated STCS DCU suction disinfection system used with single component handpieces provides an effective solution.
Collapse
Affiliation(s)
- M A Boyle
- Microbiology Research Unit, Division of Oral Biosciences, Dublin Dental University Hospital, University of Dublin, Trinity College Dublin, Lincoln Place, Dublin 2, Ireland
| | - M J O'Donnell
- Microbiology Research Unit, Division of Oral Biosciences, Dublin Dental University Hospital, University of Dublin, Trinity College Dublin, Lincoln Place, Dublin 2, Ireland
| | - R J Russell
- Department of Microbiology, University of Dublin, Trinity College Dublin, Lincoln Place, Dublin 2, Ireland
| | - N Galvin
- Moyderwell Dental Clinic, Tralee, County Kerry, Ireland
| | - J Swan
- Microbiology Research Unit, Division of Oral Biosciences, Dublin Dental University Hospital, University of Dublin, Trinity College Dublin, Lincoln Place, Dublin 2, Ireland
| | - D C Coleman
- Microbiology Research Unit, Division of Oral Biosciences, Dublin Dental University Hospital, University of Dublin, Trinity College Dublin, Lincoln Place, Dublin 2, Ireland.
| |
Collapse
|
13
|
Microbiology, genomics, and clinical significance of the Pseudomonas fluorescens species complex, an unappreciated colonizer of humans. Clin Microbiol Rev 2015; 27:927-48. [PMID: 25278578 DOI: 10.1128/cmr.00044-14] [Citation(s) in RCA: 153] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
Pseudomonas fluorescens is not generally considered a bacterial pathogen in humans; however, multiple culture-based and culture-independent studies have identified it at low levels in the indigenous microbiota of various body sites. With recent advances in comparative genomics, many isolates originally identified as the "species" P. fluorescens are now being reclassified as novel Pseudomonas species within the P. fluorescens "species complex." Although most widely studied for its role in the soil and the rhizosphere, P. fluorescens possesses a number of functional traits that provide it with the capability to grow and thrive in mammalian hosts. While significantly less virulent than P. aeruginosa, P. fluorescens can cause bacteremia in humans, with most reported cases being attributable either to transfusion of contaminated blood products or to use of contaminated equipment associated with intravenous infusions. Although not suspected of being an etiologic agent of pulmonary disease, there are a number of reports identifying it in respiratory samples. There is also an intriguing association between P. fluorescens and human disease, in that approximately 50% of Crohn's disease patients develop serum antibodies to P. fluorescens. Altogether, these reports are beginning to highlight a far more common, intriguing, and potentially complex association between humans and P. fluorescens during health and disease.
Collapse
|
14
|
Lal S, Singhrao SK, Bricknell M, Pearce M, Morton LHG, Ahmed W, Crean SJ. Monitoring Dental-Unit-Water-Line Output Water by Current In-office Test Kits. Curr Microbiol 2014; 69:135-42. [DOI: 10.1007/s00284-014-0569-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2013] [Accepted: 02/04/2014] [Indexed: 10/25/2022]
|
15
|
Güngör ND, Kadaifçiler DG, Peker OÖ. Investigation of the bacterial load and antibiotic susceptibility of dental units. ENVIRONMENTAL MONITORING AND ASSESSMENT 2014; 186:1847-1853. [PMID: 24197558 DOI: 10.1007/s10661-013-3498-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2013] [Accepted: 10/23/2013] [Indexed: 06/02/2023]
Abstract
The aim of this study was to evaluate the bacterial contamination level and to determine the antibiotic susceptibility of the isolated bacteria from dental unit waterlines (DUWLs) in Istanbul. Bacterial quality of DUWLs is very important, as patients and dental staff are regularly exposed to water and aerosols generated by the unit. If opportunistic pathogens such as Staphylococcus aureus, Pseudomonas aeruginosa, and Legionella pneumophila are present in DUWLs, patient and dental staff can be infected. One hundred water samples were collected from high-speed drills and input waters from 50 dental units. Aerobic heterotrophic bacteria counts and the presence of Legionella, Pseudomonas, oral streptococci, and Staphylococcus were investigated in dental unit waters and aerosol samples. In addition, the antibiotic susceptibility of the isolated and identified bacteria from DUWLs was examined. This research found that 37 out of 50 dental unit water samples exceeded the American Dental Association's limit of 200 colony-forming units (CFU)/mL(-1). Legionella, oral streptococci, and S. aureus were not detected in any water or aerosol samples, but P. aeruginosa was isolated in three DUWLs. Also, Pseudomonas and Staphylococcus were found in water and aerosol samples. Cefoperazone, ofloxacin, gentamicin, ciprofloxacin, and piperacillin were the most effective antibiotics against the isolated bacteria from DUWLs.
Collapse
Affiliation(s)
- Nihal Dogruöz Güngör
- Department of Biology, Faculty of Science, Istanbul University, 34134, Vezneciler, Istanbul, Turkey,
| | | | | |
Collapse
|
16
|
Ramalingam K, Frohlich NC, Lee VA. Effect of nanoemulsion on dental unit waterline biofilm. J Dent Sci 2013. [DOI: 10.1016/j.jds.2013.02.035] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
17
|
Repeated detection of microbes in beverages dispensed from soda fountain machines and the effect of flushing on microbial density. Int J Food Microbiol 2013; 163:218-22. [DOI: 10.1016/j.ijfoodmicro.2013.03.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2012] [Revised: 01/31/2013] [Accepted: 03/09/2013] [Indexed: 11/22/2022]
|
18
|
Gea-Izquierdo E, Loza-Murguia MG. Calidad del agua y Salud: Las biopelículas y Legionella. JOURNAL OF THE SELVA ANDINA RESEARCH SOCIETY 2013. [DOI: 10.36610/j.jsars.2012.030200112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
19
|
Abstract
Recent advances in research technology have allowed researchers to study bacteria in their natural environment. Dental biofilm forms via an ordered sequence of events, resulting in structured and functionally organized species rich microbial community and modern molecular biological techniques have identified about 1000 different bacterial species in the dental biofilm, twice as many as can be cultured. Sites for biofilm formation include all kinds of surfaces: natural materials above and below ground, metals, plastics, medical implant materials—even plant and body tissue. Wherever you find a combination of moisture, nutrients and a surface, you are likely to find biofilm. The biofilm is used to describe the communities of micro-organisms attached to a surface; such microbes are usually spatially organized into three-dimension structure and are enclosed in matrix of extracellular material derived both from the cells themselves and from the environment. Dental biofilm pathogenicity in the oral cavity is magnified by specific biofilm characteristics and modern molecular biological techniques have identified about 1000 different bacterial species in the dental biofilm, twice as many as can be cultured. Adaptation to a biofilm lifestyle involves regulation of a vast set of genes, and the micro-organisms are thus able to optimize phenotypic properties for the particular environment.
Collapse
Affiliation(s)
- Rajiv Saini
- Department of Periodontology and Oral Implantology, Rural Dental College, Maharashtra, India
| | | | | |
Collapse
|
20
|
Barbot V, Robert A, Rodier MH, Imbert C. Update on infectious risks associated with dental unit waterlines. ACTA ACUST UNITED AC 2012; 65:196-204. [PMID: 22469485 DOI: 10.1111/j.1574-695x.2012.00971.x] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2011] [Revised: 02/08/2012] [Accepted: 03/22/2012] [Indexed: 11/28/2022]
Abstract
Modern dental chair units consist of a network of interconnected narrow-bore plastic tubes called dental unit waterlines (DUWLs). The water delivered by these DUWLs acts as both a coolant for a range of instruments and an irrigant during dental treatments. The quality of water is of considerable importance because both patients and dental team are regularly exposed to water and aerosols generated by dental equipment. Studies have demonstrated that DUWLs provide a favourable environment for microbial proliferation and biofilm formation, and that water is consequently often contaminated with high densities of various microorganisms (bacteria, fungi, protozoa, viruses). The presence of high levels of microbial contamination may be a health problem for dentists and patients, especially those who are immunocompromised. The current status of knowledge on microbial contamination of DUWLs is presented, with an emphasis on the infectious risk associated with DUWLs and on the various approaches for disinfecting and protecting DUWLs.
Collapse
Affiliation(s)
- Vanessa Barbot
- Laboratoire de Chimie et Microbiologie de l'Eau, Université de Poitiers, Poitiers, France.
| | | | | | | |
Collapse
|
21
|
O’Donnell MJ, Boyle MA, Russell RJ, Coleman DC. Management of dental unit waterline biofilms in the 21st century. Future Microbiol 2011; 6:1209-26. [DOI: 10.2217/fmb.11.104] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
Dental chair units (DCUs) use water to cool and irrigate DCU-supplied instruments and tooth surfaces, and provide rinsewater during dental treatment. A complex network of interconnected plastic dental unit waterlines (DUWLs) supply water to these instruments. DUWLs are universally prone to microbial biofilm contamination seeded predominantly from microorganisms in supply water. Consequently, DUWL output water invariably becomes contaminated by high densities of microorganisms, principally Gram-negative environmental bacteria including Pseudomonas aeruginosa and Legionella species, but sometimes contain human-derived pathogens such as Staphylococcus aureus. Patients and staff are exposed to microorganisms from DUWL output water and to contaminated aerosols generated by DCU instruments. A wide variety of approaches, many unsuccessful, have been proposed to control DUWL biofilm. More recently, advances in biofilm science, chemical DUWL biofilm treatment agents, DCU design, supply water treatment and development of automated DUWL biofilm control systems have provided effective long-term solutions to DUWL biofilm control.
Collapse
Affiliation(s)
- Mary J O’Donnell
- Microbiology Research Unit, Division of Oral Biosciences, Dublin Dental University Hospital, University of Dublin, Trinity College Dublin, Dublin 2, Republic of Ireland
| | - Maria A Boyle
- Microbiology Research Unit, Division of Oral Biosciences, Dublin Dental University Hospital, University of Dublin, Trinity College Dublin, Dublin 2, Republic of Ireland
| | - Ronnie J Russell
- The Department of Microbiology, The Moyne Institute of Preventive Medicine, University of Dublin, Trinity College Dublin, Dublin 2, Republic of Ireland
| | | |
Collapse
|
22
|
Ferreira C, Pereira AM, Pereira MC, Melo LF, Simoes M. Physiological changes induced by the quaternary ammonium compound benzyldimethyldodecylammonium chloride on Pseudomonas fluorescens. J Antimicrob Chemother 2011; 66:1036-43. [DOI: 10.1093/jac/dkr028] [Citation(s) in RCA: 92] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
|
23
|
Boyle M, O’Donnell M, Russell R, Coleman D. Lack of cytotoxicity by Trustwater Ecasol™ used to maintain good quality dental unit waterline output water in keratinocyte monolayer and reconstituted human oral epithelial tissue models. J Dent 2010; 38:930-40. [DOI: 10.1016/j.jdent.2010.08.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2010] [Revised: 08/05/2010] [Accepted: 08/06/2010] [Indexed: 11/16/2022] Open
|
24
|
Chate RAC. An audit improves the quality of water within the dental unit water lines of general dental practices across the East of England. Br Dent J 2010; 209:E11. [PMID: 20885414 DOI: 10.1038/sj.bdj.2010.885] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/10/2010] [Indexed: 11/09/2022]
Abstract
OBJECTIVE To evaluate and improve upon the quality of water emanating from the dental unit waterlines (DUWLs) which supply irrigation for dental handpieces and triple spray syringes in general practice. DESIGN A prospective clinical audit. SETTING Seventy-two general dental practices in the East of England. METHODS In 2006, 124 dentists initially registered to participate in the audit. By 2007, 72 had begun and by 2008, 68 had completed the project. This involved collecting samples of water discharged from the DUWLs in the dental practices both before the start and mid-way through a morning session. These were tested microbiologically at a United Kingdom Accreditation Service testing laboratory. INTERVENTIONS Before the audit, 56% of the DUWLs were reportedly flushed through for 2 minutes at the start of the day, 29% were purged for 20 seconds in between each patient, 50% were treated with a wide range of different disinfectant solutions, 44% were drained down dry at the end of the day and 9% had no cross-infection control measures applied to them at all. In the audit, 100% used a disinfectant solution alone, predominantly either Alpron or Sterilox. MAIN OUTCOME MEASURES The minimum audit standard set was for the water samples to meet the United States' Centers for Disease Control and Prevention (CDC) guideline on the quality of DUWL water, namely that the United States' Environmental Protection Agency (EPA) regulatory standards for drinking water be adopted, in that no more than 5% of water samples should be contaminated with total coliforms and that they should not have more than 500 colony forming units per ml (cfu/ml) of heterotrophic water bacteria. However, the participating dentists were encouraged to try and achieve the more stringent European Union (EU) standards for potable (drinking) water, namely for the water samples to have neither Escherichia coli nor any other faecal coliforms present and for the aerobic colony count to be less than 100 cfu/ml at 22°C after 72 hours of culturing. RESULTS In the pre-audit survey, none of the 72 DUWL water samples were contaminated with E. coli but in five of them (7%) coliforms were recovered. Only 25% reached the EU potable water standard, of which 11% had zero planktonic bacterial contamination. Three percent were above the EU standard but below the CDC guideline/EPA regulatory drinking water standard, while alarmingly, 72% of them failed to reach this minimum audit standard altogether. However, after the application of a suitable disinfectant for at least a month, the audit revealed that E. coli still remained absent in the water samples taken from the 68 DUWLs that completed the project and in only one (1.5%) were coliforms recovered. Remarkably, nearly 81% reached the EU potable water standard, of which 54% had zero planktonic bacterial contamination, with nearly an additional 6% reaching the American CDC/EPA standard and with only 13% failing outright. CONCLUSIONS Clinical audit using appropriate DUWL disinfectants can result in the improvement of the quality of water that is discharged through DUWLs, thereby minimising both the risk of cross-infection to vulnerable patients as well as to dental staff chronically exposed to contaminated aerosols.
Collapse
Affiliation(s)
- R A C Chate
- Orthodontic Department, Essex County Hospital, Lexden Road, Colchester, UK
| |
Collapse
|
25
|
Yousefshahi F, Khajavi MR, Anbarafshan M, Khashayar P, Najafi A. Sanosil, a more effective agent for preventing the hospital-acquired ventilator associated pneumonia. Int J Health Care Qual Assur 2010; 23:583-90. [PMID: 20845824 DOI: 10.1108/09526861011060942] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE The aim of this study is to compare the effects of Sanosil and glutaraldehyde 2 percent in disinfecting ventilator connecting tubes in an intensive care unit (ICU) environment. DESIGN/METHODOLOGY/APPROACH The 12-week open-labelled clinical trial was conducted in the surgical ICU of a teaching hospital from March to May 2005. In the first phase of the study, high level disinfection was performed using glutaraldehyde 2 percent, whereas Sanosil was used as the disinfectant agent of the second phase. Samples for microbial culture were obtained from the Y piece, the expiratory limb proximal to the ventilator and the humidifier in different stages; the results were then compared. FINDINGS Positive culture was more frequently reported in Y pieces, humidifiers and expiratory end of ventilators. Comparing the two groups, there were more positive cultures in the glutaraldehyde group (p value = 0.005); multiple organism growths, gram negative, gram positive and fungi were also more frequent in this group (p value = 0.01; 0. 007; 0. 062; 0.144, respectively). ORIGINALITY/VALUE The paper shows that Sanosil is an effective agent in reducing the contamination risk in the tubes used in ICUs.
Collapse
|
26
|
Coleman DC, O'Donnell MJ, Boyle M, Russell R. Microbial biofilm control within the dental clinic: reducing multiple risks. J Infect Prev 2010. [DOI: 10.1177/1757177410376845] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
This short review focuses on biofilms in the dental clinic environment. Microbial biofilms are potentially a significant source of cross-contamination and cross-infection in the dental clinic. Biofilms in dental chair unit waterlines (DUWLs), suction hoses and fittings pose the most significant risk as these may come into contact with the patient during treatment. These can be managed effectively by regular disinfection using chemical disinfectants and procedures that have proven efficacy. As dental chair units (DCUs) are classified as medical devices, there is a requirement for DCU manufacturers to provide detailed guidance for their decontamination. Planned routine preventive maintenance of the dental clinic water network and good quality water will considerably minimise infection risks from microorganisms in tap water and has benefits for the operation of other clinic equipment. Regular and effective cleaning and disinfection of taps, sinks and splash-backs will help to minimise reservoirs and disseminators of potentially pathogenic bacteria from these areas.
Collapse
Affiliation(s)
- David C Coleman
- Dublin Dental School and Hospital, Trinity College Dublin, Lincoln Place, Dublin, Ireland,
| | - Mary J O'Donnell
- Dublin Dental School and Hospital, Trinity College Dublin, Lincoln Place, Dublin, Ireland
| | - Maria Boyle
- Dublin Dental School and Hospital, Trinity College Dublin, Lincoln Place, Dublin, Ireland
| | - Ronnie Russell
- Department of Microbiology, Trinity College Dublin, Dublin, Ireland
| |
Collapse
|
27
|
Doğruöz N, Göksay D, Ilhan-Sungur E, Cotuk A. Pioneer colonizer microorganisms in biofilm formation on galvanized steel in a simulated recirculating cooling-water system. J Basic Microbiol 2009; 49 Suppl 1:S5-12. [PMID: 19455520 DOI: 10.1002/jobm.200800250] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Some bacteria have a higher tendency to produce biofilm than others. Especially, Pseudomonas and Aeromonas strains are acknowledged to be pioneer colonizers and are predominant in biofilm formation. We examined biofilm formation and first attachment maintance of biofilms of Pseudomonas spp., Pseudomonas aeruginosa, Aeromonas spp, sulphate reducing bacteria and filamentous fungi. A simulated recirculating cooling-water system was used. Heterotrophic bacteria counts on galvanized steel and glass surfaces rose during the tidy period of 720 hours. In addition, we determined that although Pseudomonas spp., Pseudomonas aeruginosa and Aeromonas spp. were the pioneer colonizers, they surprisingly could not be determined in the biofilms on both types of surface after 456 hours. Sulphate reducing bacteria were observed in biofilms on both surfaces from the outset of the experiments. Filamentous fungi were seen on the galvanized steel and glass surfaces after 0.5 h.
Collapse
Affiliation(s)
- Nihal Doğruöz
- Department of Biology, Faculty of Science, Istanbul University, Vezneciler, Istanbul, Turkey.
| | | | | | | |
Collapse
|
28
|
O’Donnell M, Boyle M, Swan J, Russell R, Coleman D. A centralised, automated dental hospital water quality and biofilm management system using neutral Ecasol™ maintains dental unit waterline output at better than potable quality: A 2-year longitudinal study. J Dent 2009; 37:748-62. [DOI: 10.1016/j.jdent.2009.06.001] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2009] [Revised: 06/02/2009] [Accepted: 06/03/2009] [Indexed: 10/20/2022] Open
|
29
|
Coleman DC, O'Donnell MJ, Shore AC, Russell RJ. Biofilm problems in dental unit water systems and its practical control. J Appl Microbiol 2009; 106:1424-37. [PMID: 19187140 DOI: 10.1111/j.1365-2672.2008.04100.x] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- D C Coleman
- Microbiology Research Unit, Division of Oral Biosciences, Dublin Dental School & Hospital, University of Dublin, Trinity College Dublin, Lincoln Place, Dublin 2, Ireland.
| | | | | | | |
Collapse
|
30
|
Percival RS, Devine DA, Nattress B, Kite P, Marsh PD. Control of microbial contamination in dental unit water systems using tetra-sodium EDTA. J Appl Microbiol 2009; 107:1081-8. [PMID: 19486406 DOI: 10.1111/j.1365-2672.2009.04299.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
AIM To examine the efficacy of tetra-sodium EDTA in controlling microbial contamination of dental unit water systems (DUWS). METHODS AND RESULTS Ten dental units were treated once a week with either 4% or 8% tetra-sodium EDTA for four or two consecutive weeks, respectively. Before treatment, 43% and 60% of the water samples from the air/water triple syringe and high-speed hand-pieces, respectively, exceeded the American Dental Association (ADA) guidelines of 200 CFU ml(-1) water during a 6-week baseline period. After each weekend treatment, the levels of microbial contamination in all DUWS fell significantly (P < 0.001) to below the ADA guideline. By the end of the week, microbial counts in the outflowing water had returned to baseline levels indicating a transient effect of single doses of tetra-sodium EDTA, and the need for multiple applications. The biofilms were virtually eliminated after a single weekend treatment. CONCLUSIONS Tetra-sodium EDTA is effective in controlling microbial contamination in DUWS. SIGNIFICANCE AND IMPACT OF THE STUDY Inexpensive, effective and safe products for reducing the microbial load of water from DUWS are needed to meet ADA and other national guidelines. Tetra-sodium EDTA can significantly reduce microbial biofilms and bacterial counts in outflowing water, and is compatible for use in DUWS.
Collapse
Affiliation(s)
- R S Percival
- Department of Oral Biology, Leeds Dental Institute, Clarendon Way, Leeds LS2 9LU, UK.
| | | | | | | | | |
Collapse
|
31
|
Zanetti F, De Luca G, Sacchetti R. Control of bacterial contamination in microfiltered water dispensers (MWDs) by disinfection. Int J Food Microbiol 2009; 128:446-52. [DOI: 10.1016/j.ijfoodmicro.2008.10.007] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2008] [Revised: 09/18/2008] [Accepted: 10/04/2008] [Indexed: 11/26/2022]
|
32
|
Liaqat I, Bachmann RT, Nasim Sabri A, Edyvean RGJ, Biggs CA. Investigating the effect of patulin, penicillic acid and EDTA on biofilm formation of isolates from dental unit water lines. Appl Microbiol Biotechnol 2008; 81:349-58. [DOI: 10.1007/s00253-008-1691-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2008] [Revised: 08/25/2008] [Accepted: 08/26/2008] [Indexed: 11/29/2022]
|
33
|
Gawande PV, LoVetri K, Yakandawala N, Romeo T, Zhanel GG, Cvitkovitch DG, Madhyastha S. Antibiofilm activity of sodium bicarbonate, sodium metaperiodate and SDS combination against dental unit waterline-associated bacteria and yeast. J Appl Microbiol 2008; 105:986-92. [PMID: 18422552 DOI: 10.1111/j.1365-2672.2008.03823.x] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
AIM To determine the effect of sodium bicarbonate (SB), sodium metaperiodate (SMP) and sodium dodecyl sulfate (SDS) combination on biofilm formation and dispersal in dental unit waterline (DUWL)-associated bacteria and yeast. METHODS AND RESULTS The in vitro effect of SB, SMP and SDS alone and in combination on biofilm formation and dispersal in Pseudomonas aeruginosa, Klebsiella pneumoniae, Actinomyces naeslundii, and Candida albicans was investigated using a 96-well microtitre plate biofilm assay. The combination showed a broad-spectrum inhibitory effect on growth as well as biofilm formation of both gram-negative and gram-positive bacteria, and yeast. In addition, the SB + SMP + SDS combination was significantly more effective in dispersing biofilm than the individual compounds. The combination dispersed more than 90% of P. aeruginosa biofilm whereas the commercial products, Oxygenal 6, Sterilex Ultra, and PeraSafe showed no biofilm dispersal activity. CONCLUSION The composition comprising SB, SMP, and SDS was effective in inhibiting as well as dispersing biofilms in DUWL-associated bacteria and yeast. SIGNIFICANCE AND IMPACT OF THE STUDY This study shows that a composition comprising environmentally friendly and biologically safe compounds such as SB, SMP, and SDS has a potential application in reducing DUWL-associated acquired infections in dental clinics.
Collapse
|
34
|
Ma’ayeh SY, Al-Hiyasat AS, Hindiyeh MY, Khader YS. Legionella pneumophila contamination of a dental unit water line system in a dental teaching centre. Int J Dent Hyg 2008; 6:48-55. [DOI: 10.1111/j.1601-5037.2007.00280.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
35
|
Simões M, Simões LC, Cleto S, Machado I, Pereira MO, Vieira MJ. Antimicrobial mechanisms of ortho-phthalaldehyde action. J Basic Microbiol 2007; 47:230-42. [PMID: 17518416 DOI: 10.1002/jobm.200610280] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Biocides generally have multiple biochemical targets. Such a feature easily entangles the analysis of the mechanisms of antimicrobial action. In this study, the action of the dialdehyde biocide ortho-phtalaldehyde (OPA), on bacteria, was investigated using the Gram-negative Pseudomonas fluorescens. The targets of the biocide action were studied using different bacterial physiological indices. The respiratory activity, membrane permeabilization, physico-chemical characterization of the bacterial surfaces, outer membrane proteins (OMP) expression, concomitant influence of pH, contact time and presence of bovine serum albumin (BSA) on respiratory activity, morphological changes and OPA-DNA interactions were assessed for different OPA concentrations. With the process conditions used, the minimum inhibitory concentration was 1500 mg/l, the concentration to promote total loss of bacterial culturability was 65 mg/l and the concentration needed to inactivate respiratory activity was 80 mg/l. These data are evidence that culturability and respiratory activity were markedly affected by the biocide. OPA lead, moreover, to a significant change in cell surface hydrophobicity and induced propidium iodide uptake. Such results suggest cytoplasmic membrane damage, although no release of ATP was detected. At pH 5, the bactericidal action of OPA was stronger, though not influenced by BSA presence. Nevertheless, at pH 9, BSA noticeably (p < 0.05) impaired biocide action. A time-dependent effect in OPA action was evident when contemplating respiratory activity variation, mainly for the lower exposure times. Scanning electron microscopy allowed to detect bacterial morphological changes, translated on cellular elongation, for OPA concentrations higher than 100 mg/l. Interferences at DNA level were, however, restricted to extreme biocide concentrations. The overall bactericidal events occurred without detectable OMP expression changes. In conclusion, the results indicated a sequence of events responsible for the antimicrobial action of OPA: it binds to membrane receptors due to cross-linkage; impairs the membrane functions allowing the biocide to enter through the permeabilized membrane; it interacts with intracellular reactive molecules, such as RNA, compromising the growth cycle of the cells and, at last, with DNA.
Collapse
Affiliation(s)
- Manuel Simões
- IBB-Institute for Biotechnology and Bioengineering, Centre for Biological Engineering, Universidade do Minho, Campus de Gualtar, Braga, Portugal.
| | | | | | | | | | | |
Collapse
|
36
|
Coleman DC, O'Donnell MJ, Shore AC, Swan J, Russell RJ. The role of manufacturers in reducing biofilms in dental chair waterlines. J Dent 2007; 35:701-11. [PMID: 17576035 DOI: 10.1016/j.jdent.2007.05.003] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2007] [Revised: 05/03/2007] [Accepted: 05/08/2007] [Indexed: 01/23/2023] Open
Abstract
OBJECTIVES This paper reviews how dental chair unit (DCU) manufacturers can contribute practically to resolving the problem of biofilm formation in dental unit waterlines (DUWs). STUDY SELECTION The review concentrates on how novel developments and changes in a range of specific areas have, and might contribute to DUW biofilm control. These include (i) DCU engineering and design changes; (ii) improvements to DCU supply water quality; (iii) development of automated DUW treatment procedures that are effective at controlling biofilm in the long-term, safe for patients and dental staff, environmentally friendly and which do not exhibit adverse effects on DCU components after prolonged use. SOURCES The majority of the material contained in this review is based on, or supported by the peer-reviewed literature. DATA The current consensus from the literature reveals that the emphasis on DUW biofilm and its control has focused on describing the problem and its control using a range of periodic and residual DUW treatment agents. Unfortunately, until recently, DCU manufacturers have provided very little specific guidance in this regard. Indeed, ensuring that DCUs provide good quality output water has generally been regarded to be the responsibility of dental practitioners. Some recent studies have shown that novel DCUs with integral semi-automated or automated DUW cleaning systems can effectively control DUW biofilm in the long-term. However, there are other potential DCU engineering and design changes that DCU manufacturers could undertake to further improve DUW biofilm control. CONCLUSIONS DCU manufacturers can significantly contribute to controlling the problem of DUW biofilm.
Collapse
Affiliation(s)
- D C Coleman
- Microbiology Research Unit, Division of Oral Biosciences, Dublin Dental School & Hospital, University of Dublin, Trinity College Dublin, Lincoln Place, Dublin 2, Ireland.
| | | | | | | | | |
Collapse
|
37
|
Walker JT, Marsh PD. Microbial biofilm formation in DUWS and their control using disinfectants. J Dent 2007; 35:721-30. [PMID: 17714847 DOI: 10.1016/j.jdent.2007.07.005] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2007] [Revised: 07/03/2007] [Accepted: 07/03/2007] [Indexed: 01/10/2023] Open
Abstract
OBJECTIVES Due to the presence of extended narrow bore tubing and long periods of stagnation, dental unit water systems (DUWs) can be prone to relatively high levels of microbial contamination, including the formation of biofilm and the presence of opportunistic pathogens, irrespective of the source and quality of the inflowing water. Whilst the European Union (EU) has yet to set a definitive microbiological guideline, the American Dental Association (ADA) has set a maximum of <200 colony forming units (cfu)/ml for DUWs water in the USA. The objective of this review is to discuss why microbial contamination and biofilms are so prevalent in DUWs, as well as the role of disinfectants and their potential for achieving microbial water quality levels recommended by the ADA. STUDY SELECTION The review outlines the principal factors responsible for biofilm formation in DUWs and a number of mechanisms used for microbial control. SOURCES The source material contained in this review is taken from the peer-reviewed literature. DATA A variety of disinfectants are available for use, but controlled laboratory and clinical studies have shown that they can vary markedly in their efficacy and suitability for use. Some products have been shown to successfully remove biofilm and consistently reduce the microbial load of out-flowing water to <200 cfu/ml. CONCLUSIONS The effective delivery of approved disinfectants can control the level of microorganisms in DUWs at acceptable levels.
Collapse
Affiliation(s)
- J T Walker
- Centre for Emergency Preparedness and Response, HPA Porton Down, Salisbury, United Kingdom
| | | |
Collapse
|
38
|
Pankhurst CL, Coulter WA. Do contaminated dental unit waterlines pose a risk of infection? J Dent 2007; 35:712-20. [PMID: 17689168 DOI: 10.1016/j.jdent.2007.06.002] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2007] [Revised: 06/01/2007] [Accepted: 06/05/2007] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVES To review the evidence that the dental unit waterlines are a source of occupational and healthcare acquired infection in the dental surgery. DATA Transmission of infection from contaminated dental unit waterlines (DUWL) is by aerosol droplet inhalation or rarely imbibing or wound contamination in susceptible individuals. Most of the organisms isolated from DUWL are of low pathogenicity. However, data from a small number of studies described infection or colonisation in susceptible hosts with Legionella spp., Pseudomonas spp. and environmental mycobacteria isolated from DUWL. The reported prevalence of legionellae in DUWL varies widely from 0 to 68%. The risk from prolonged occupational exposure to legionellae has been evaluated. Earlier studies measuring surrogate evidence of exposure to legionellae in dental personnel found a significant increase in legionella antibody levels but in recent multicentre studies undertaken in primary dental care legionellae were isolated at very low rate and the corresponding serological titres were not above background levels. Whereas, a case of fatal Legionellosis in a dental surgeon concluded that the DUWL was the likely source of the infection. The dominant species isolated from dental unit waterlines (DUWL) are Gram-negative bacteria, which are a potent source of cell wall endotoxin. A consequence of indoor endotoxin exposure is the triggering or exacerbation of asthma. Data from a single large practice-based cross-sectional study reported a temporal association between occupational exposure to contaminated DUWL with aerobic counts of >200cfu/mL at 37 degrees C and development of asthma in the sub-group of dentists in whom asthma arose following the commencement of dental training. SOURCES Medline 1966 to February 2007 was used to identify studies for this paper. STUDY SELECTION Design criteria included randomised control trials, cohort, and observational studies in English. CONCLUSIONS Although the number of published cases of infection or respiratory symptoms resulting from exposure to water from contaminated DUWL is limited, there is a medico-legal requirement to comply with potable water standards and to conform to public perceptions on water safety.
Collapse
Affiliation(s)
- Caroline L Pankhurst
- Department of Oral Medicine, King's College London Dental Institute, Bessemer Road, London, United Kingdom.
| | | |
Collapse
|
39
|
O'Donnell MJ, Shore AC, Russell RJ, Coleman DC. Optimisation of the long-term efficacy of dental chair waterline disinfection by the identification and rectification of factors associated with waterline disinfection failure. J Dent 2007; 35:438-51. [PMID: 17303302 DOI: 10.1016/j.jdent.2007.01.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2006] [Revised: 12/22/2006] [Accepted: 01/03/2007] [Indexed: 11/18/2022] Open
Abstract
UNLABELLED Although many studies have highlighted the problem of biofilm growth in dental chair unit waterlines (DUWs), no long-term studies on the efficacy of DUW disinfection using a large number of dental chair units (DCUs) have been reported. OBJECTIVES To investigate the long-term (21 months) efficacy of the Planmeca Waterline Cleaning System (WCS) to maintain the quality of DUW output water below the American Dental Association (ADA) recommended standard of < or =200cfu/mL of aerobic heterotrophic bacteria using once weekly disinfection with the hydrogen peroxide-and silver ion-containing disinfectant Planosil. METHODS Microbiological quality of DUW output water was monitored by culture on R2A agar for 10 DCUs fitted with the WCS. The presence of biofilm in DUWs was examined by electron microscopy. RESULTS During the first 9 months a high prevalence (28/300 disinfection cycles; 9.3%) of intermittent DUW disinfection failure occurred in 8/10 DCUs due to operator omission to disinfect all DUWs (10/28 failed cycles), incorrect compressed air pressure failing to distribute the disinfectant properly (4/28 failed cycles) and physical blockage of disinfectant intake valves due to corrosion effects of Planosil (14/28 failed cycles). On rectification of these faults through engineering redesign and procedural changes, no further cases of intermittent DUW disinfection failure were observed. Independently of these factors, a rapid and consistent decline in efficacy of DUW disinfection occurred in 4/10 DCUs following the initial 9 months of once weekly disinfection. There was a highly significant difference (P<0.0001) in the prevalence of strongly catalase-positive Novosphingobium and Sphingomonas bacterial species (mean average prevalence of 37.1%) in DUW output water from these 4 DCUs compared to the other 6 DCUs and DCU supply water (prevalence <1%), which correlated with biofilm presence in the DUWs and indicated selective pressure for maintenance of these species by prolonged disinfectant usage. Planosil was reformulated to a more concentrated form (Planosil Forte) and when used once weekly was found to maintain bacterial density in output water below the ADA standard for all 10 DCUs. CONCLUSIONS A variety of factors can contribute to failure of DUW disinfection in the long-term, including human error, disinfectant corrosion of equipment and natural selection of naturally disinfectant-tolerant bacterial species.
Collapse
Affiliation(s)
- M J O'Donnell
- Microbiology Research Unit, Division of Oral Biosciences, Dublin Dental School & Hospital, University of Dublin, Trinity College Dublin, Lincoln Place, Dublin 2, Ireland
| | | | | | | |
Collapse
|
40
|
Chate RAC. An audit improves the quality of water within the dental unit water lines of three separate facilities of a United Kingdom NHS Trust. Br Dent J 2007; 201:565-9. [PMID: 17099661 DOI: 10.1038/sj.bdj.4814206] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/09/2006] [Indexed: 11/09/2022]
Abstract
OBJECTIVE To improve the quality of water emanating from dental unit waterlines (DUWLs). DESIGN A prospective clinical audit. SETTING Three geographically separate district dental facilities of a United Kingdom NHS Trust, involving two community clinics and one hospital orthodontic department, which were evaluated between 2002 and 2004. METHODS Samples of water discharged from the DUWLs were collected prior to the start and midway through a morning session. These were tested microbiologically at a United Kingdom Accreditation Service testing laboratory within six hours of sampling. INTERVENTIONS One of the clinics followed the contemporaneous BDA advice of flushing water through its DUWLs while the other two clinics used separate intermittent disinfection purging regimes instead. One of them used a two stage protocol of Ethylene Diamine Tetra-Acetic acid followed by hydrogen peroxide, while the other used Bio 2000 as a single agent, which was subsequently superseded by the continuous use of super-oxidised water (Sterilox). MAIN OUTCOME MEASURE To assess whether the samples either met the American Dental Association's guideline on the quality of DUWL water, or the more stringent European Union standards for potable (drinking) water. RESULTS The two units which used a disinfection regime both complied with the ADA guideline and the EU potable water standard. However, the unit which only flushed through its DUWLs without using a disinfectant failed to comply with either of them. After all three dental facilities subsequently standardised their DUWL disinfection regimes by using Bio 2000, the colony counts from all of the water samples thereafter remained well below the EU recommended level. The unit which progressed to using Sterilox as a continuous disinfectant achieved and maintained zero readings from its water samples. CONCLUSIONS Clinical audit can result in the improvement of the quality of water that is discharged through DUWLs, thereby minimising both the risk of cross infection to vulnerable patients, as well as to dental staff chronically exposed to contaminated aerosols.
Collapse
Affiliation(s)
- R A C Chate
- Orthodontic Department, Essex County Hospital, Lexden Road, Colchester, CO3 3NB.
| |
Collapse
|
41
|
Al-Hiyasat AS, Ma'ayeh SY, Hindiyeh MY, Khader YS. The presence of Pseudomonas aeruginosa in the dental unit waterline systems of teaching clinics. Int J Dent Hyg 2007; 5:36-44. [PMID: 17250577 DOI: 10.1111/j.1601-5037.2007.00221.x] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
OBJECTIVE The objective of this study was to evaluate the extent of Pseudomonas aeruginosa contamination of Dental Unit Water (DUW) at a Dental Teaching Center in Jordan. METHODS Water samples were collected from 30 dental units, 10 from each of three teaching clinics, namely conservative dentistry, periodontology, and prosthodontics. Samples were collected from the outlet of the air/water syringe, high-speed handpiece and water cup filler, at the beginning of the working day (before use), after 2 min flushing, and at midday. RESULTS P. aeruginosa was detected in 86.7% (26/30) of the dental units at the beginning of the working day, and in 73.3% (22/30) after 2 min of flushing and at midday. Conservative dentistry units had the highest counts, followed by periodontology and prosthodontics (P<0.05). Overall, the highest counts (log10 count CFU ml-1) were at the beginning of the working day (1.38+/-1.05), and the lowest counts after flushing for 2 min (1.10+/-1.03), and higher numbers were seen again at midday (1.15+/-1.04) (P<0.05). CONCLUSIONS 86.7% of the dental units were contaminated with P. aeruginosa, the conservative dentistry units had the highest amount of contamination. Flushing the DUW for 2 min significantly reduced the counts of P. aeruginosa.
Collapse
Affiliation(s)
- A S Al-Hiyasat
- Department of Restorative Dentistry, Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan.
| | | | | | | |
Collapse
|
42
|
O'Donnell MJ, Shore AC, Coleman DC. A novel automated waterline cleaning system that facilitates effective and consistent control of microbial biofilm contamination of dental chair unit waterlines: A one-year study. J Dent 2006; 34:648-61. [PMID: 16442201 DOI: 10.1016/j.jdent.2005.12.006] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2005] [Revised: 12/02/2005] [Accepted: 12/09/2005] [Indexed: 10/25/2022] Open
Abstract
Microbial contamination of dental chair unit (DCU) output water caused by biofilm growth in dental unit waterlines (DUWs) is a universal problem and a potentially significant source of cross-infection. The microbial quality of output water from a Planmeca Compact i DCU equipped with the novel Water Management System (WMS), an integrated and automated DUW cleaning system, was investigated over a 12-month period with the hydrogen peroxide- and silver ion-containing disinfectants Planosil and Planosil Forte. Four weeks after connection to the potable-water quality mains supply the density of aerobic heterotrophic bacteria, rose from the low levels consistently found in the supply water throughout this study (mean average 77 cfu/mL) to 15,400 cfu/mL. Disinfection of DUWs once weekly with Planosil for 10 weeks resulted in a dramatic reduction in bacterial density immediately following disinfection (mean average 26 cfu/mL). Bacterial density rose steadily between disinfections and by 7 days post-disinfection, water quality failed (mean average 384 cfu/mL) the American Dental Association DCU water quality standard of <or=200 cfu/mL. The DCU was then disinfected once weekly for 40 weeks with Planosil Forte. The average bacterial density immediately post-disinfection was 20 cfu/mL and 7 days post-disinfection was 113 cfu/mL. Electron microscopy showed that improved output water quality following disinfection with both disinfectants was associated with marked elimination of DUW biofilm, but deterioration of water quality following disinfection was associated with its regrowth. The most common bacterial species cultured from the mains water and the DCU output water were Microcococcus luteus and Sphingomonas spp., respectively, the latter of which are known opportunistic pathogens. The findings of this study show that the Planmeca Compact i DCU equipped with the easy to use and automated WMS, that requires minimal effort on the part of the operator, consistently provides output water that passes the ADA quality standard of <or=200 cfu/mL for up to 7 days following once-weekly disinfection with Planosil Forte.
Collapse
Affiliation(s)
- M J O'Donnell
- Microbiology Research Unit, Division of Oral Biosciences, Dublin Dental School & Hospital, University of Dublin, Trinity College, Lincoln Place, Dublin 2, Republic of Ireland
| | | | | |
Collapse
|
43
|
Chaberny IF, Kaiser P, Sonntag HG. Can soda fountains be recommended in hospitals? Int J Hyg Environ Health 2006; 209:471-5. [PMID: 16740412 DOI: 10.1016/j.ijheh.2006.04.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2005] [Revised: 04/05/2006] [Accepted: 04/09/2006] [Indexed: 11/17/2022]
Abstract
Mineral water (soda water) is very popular in Germany. Therefore, soda fountains were developed as alternatives to the traditional deposit bottle system. Nowadays, different systems of these devices are commercially available. For several years, soda fountains produced by different companies have been examined at the University Hospital of Heidelberg. In 1998, it was possible for the first time to observe and evaluate one of these systems over a period of 320 days in a series of microbiological examinations. The evaluation was implemented on the basis of the German drinking water regulation (Anonymous, 1990. Gesetz über Trinkwasser und Wasser für Lebensmittelbetriebe (Trinkwasserverordnung - TrinkwV) vom 12. Dezember 1990. Bundesgesetzblatt 66, 2613ff). Initially, the bacteria counts exceeded the reference values imposed by the German drinking water regulation in almost 50% of the analyses. Pseudomonas aeruginosa was also detected in almost 38% of the samples. After a re-arrangement of the disinfection procedure and the removal of the charcoal filter, Pseudomonas aeruginosa was not detectable any more. However, the bacteria counts still frequently exceeded the reference values of the German drinking water regulation. Following our long-term analysis, we would not recommend soda fountains in high-risk areas of hospitals. If these devices are to be used in hospitals, the disinfection procedures should be executed in weekly or fortnightly intervals and the water quality should be examined periodically.
Collapse
Affiliation(s)
- Iris F Chaberny
- Department of Medical Microbiology and Hygiene, Institute of Hygiene at the University Hospital of Heidelberg, Germany.
| | | | | |
Collapse
|
44
|
Kamma JJ, Bradshaw DJ, Fulford MR, Marsh PD, Frandsen E, Ostergaard E, Schel AJ, ten Cate JM, Moorer WR, Mavridou A, Mandilara G, Stoesser L, Kneist S, Araujo R, Contreras N, Goroncy-Bermes P, Burke F, O'Mullane D, O'Sullivan M, Walker JT. Attitudes of general dental practitioners in Europe to the microbial risk associated with dental unit water systems. Int Dent J 2006; 56:187-95. [PMID: 16972392 DOI: 10.1111/j.1875-595x.2006.tb00093.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
UNLABELLED Dental Unit Water Systems (DUWS) are used in dental practices to provide water for cooling of dental equipment and irrigation of the oral cavity. However, they have been demonstrated to be contaminated with micro-organisms. There are currently no European Union (EU) Commission guidelines for the microbial quality of water discharged by DUWS. This study was part of an EU research programme to investigate the microbial contamination of DUWS in general dental practice (GDP) in the UK, Denmark, Germany, The Netherlands, Ireland, Greece and Spain. OBJECTIVE To undertake a questionnaire survey on the type of DUWS in use and determine the attitude of GDPs to the risk of microbial infection from DUWS. MATERIALS AND METHODS The questionnaire was written and translated into the language of each country before being posted to each participating dentist. Dentists were asked to complete the questionnaire survey and return it by post. RESULTS AND CONCLUSIONS The major findings were that the majority of dentists did not clean, disinfect or determine the microbial load of their DUWS, and that dentists would welcome regular monitoring and advice on maintaining their DUWS; the introduction of guidelines; and recommendations on controlling the microbial load of DUWS.
Collapse
Affiliation(s)
- J J Kamma
- Technological Educational Institute, Athens, Greece
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
45
|
Schel AJ, Marsh PD, Bradshaw DJ, Finney M, Fulford MR, Frandsen E, Østergaard E, ten Cate JM, Moorer WR, Mavridou A, Kamma JJ, Mandilara G, Stösser L, Kneist S, Araujo R, Contreras N, Goroncy-Bermes P, O'Mullane D, Burke F, O'Reilly P, Hourigan G, O'Sullivan M, Holman R, Walker JT. Comparison of the efficacies of disinfectants to control microbial contamination in dental unit water systems in general dental practices across the European Union. Appl Environ Microbiol 2006; 72:1380-7. [PMID: 16461690 PMCID: PMC1392914 DOI: 10.1128/aem.72.2.1380-1387.2006] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2005] [Accepted: 11/28/2005] [Indexed: 11/20/2022] Open
Abstract
Water delivered by dental unit water systems (DUWS) in general dental practices can harbor high numbers of bacteria, including opportunistic pathogens. Biofilms on tubing within DUWS provide a reservoir for microorganisms and should be controlled. This study compared disinfection products for their ability to meet the American Dental Association's guideline of <200 CFU x ml(-1) for DUWS water. Alpron, BioBlue, Dentosept, Oxygenal, Sanosil, Sterilex Ultra, and Ster4Spray were tested in DUWS (n = 134) in Denmark, Germany, Greece, Ireland, The Netherlands, Spain, and the United Kingdom. Weekly water samples were tested for total viable counts (TVCs) on yeast extract agar, and, where possible, the effects of products on established biofilm (TVCs) were measured. A 4- to 5-week baseline measurement period was followed by 6 to 8 weeks of disinfection (intermittent or continuous product application). DUWS water TVCs before disinfection ranged from 0 to 5.41 log CFU x ml(-1). Disinfectants achieved reductions in the median water TVC ranging from 0.69 (Ster4Spray) to 3.11 (Dentosept) log CFU x ml(-1), although occasional high values (up to 4.88 log CFU x ml(-1)) occurred with all products. Before treatment, 64% of all baseline samples exceeded American Dental Association guidelines, compared to only 17% following commencement of treatment; where tested, biofilm TVCs were reduced to below detectable levels. The antimicrobial efficacies of products varied (e.g., 91% of water samples from DUWS treated with Dentosept or Oxygenal met American Dental Association guidelines, compared to 60% of those treated with Ster4Spray). Overall, the continuously applied products performed better than those applied intermittently. The most effective products were Dentosept and Oxygenal, although Dentosept gave the most consistent and sustained antimicrobial effect over time.
Collapse
Affiliation(s)
- A J Schel
- Department of Medical Microbiology, Academic Medical Centre, Amsterdam, The Netherlands
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
46
|
O'Donnell MJ, Tuttlebee CM, Falkiner FR, Coleman DC. Bacterial contamination of dental chair units in a modern dental hospital caused by leakage from suction system hoses containing extensive biofilm. J Hosp Infect 2005; 59:348-60. [PMID: 15749324 DOI: 10.1016/j.jhin.2004.10.001] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2004] [Accepted: 10/06/2004] [Indexed: 11/27/2022]
Abstract
Within six months of opening of the new Dublin Dental Hospital in September 1998, areas of corrosion were observed on many of the baseplates of the hospital's 103 dental chair units (DCUs) at the site of attachment of the suction hoses. The corroded areas were heavily contaminated with Pseudomonas spp. and related genera posing a risk of cross-infection, particularly for immunocompromised patients. These species were used as marker organisms to investigate the source of the contamination. P. aeruginosa was the predominant species recovered from 41 selected DCU baseplates (61% prevalence), whereas P. putida (46% prevalence) and P. aeruginosa (43% prevalence) were predominant at the attachment ends of 37 selected high-volume suction hoses. Forty-one selected isolates of P. aeruginosa from 13 DCU baseplates, 16 high-volume suction hoses and 12 coarse filter housings (another suction system site) from 19 separate DCUs were serotyped to determine the similarity of isolates at each site. The majority of isolates (68.3%) belonged to serotype O:10, while the remainder belonged to serotypes O:6 (7.3%), O:11 (7.3%), O:14 (9.8%) and O:5/O:16 (7.3%). Of the isolates from DCU baseplates, additional isolates with the same serotype were recovered from other suction system sites in 10/13 (77%) cases. Isolates of only one serotype were recovered from each of the 19 DCUs investigated. Forty-one serotyped isolates were also subject to computer-assisted analysis of SpeI-generated DNA fingerprint profiles, and similarity coefficient (S(AB)s) values were calculated for each pairwise combination of isolate profiles. The data obtained showed that the isolates consisted of two distinct main populations, each containing separate clades corresponding to specific serotypes. Serotype O:6 (three isolates), O:11 (three isolates) and O:5/O:16 (three isolates) belonged to a single strain in each case. Serotypes O:14 (four isolates) and O:10 (28 isolates) belonged to two strains in each case. The two serotype O:10 strains, termed fingerprint groups I (four isolates from three DCUs) and II (24 isolates from 10 DCUs), were the most distantly related of all the strains identified. These findings demonstrated that the hospital DCUs had become colonized with a small number of P. aeruginosa strains, one of which (serotype O:10, fingerprint group II) predominated. These results also confirmed that DCU baseplate contamination was most likely to be due to leakage from suction system hoses at the baseplate attachment sites, probably due to loosening during use. Replacement hose connectors that firmly retained the suction hoses in the attachment sites so that they could not be loosened by movement of the suction hoses solved this problem, and eliminated further contamination of the DCU baseplates.
Collapse
Affiliation(s)
- M J O'Donnell
- Microbiology Research Unit, Department of Oral Surgery, Oral Medicine and Oral Pathology, School of Dental Science & Dublin Dental Hospital, University of Dublin, Trinity College, Lincoln Place, Dublin 2, Republic of Ireland
| | | | | | | |
Collapse
|
47
|
Walker JT, Bradshaw DJ, Finney M, Fulford MR, Frandsen E, ØStergaard E, Ten Cate JM, Moorer WR, Schel AJ, Mavridou A, Kamma JJ, Mandilara G, Stösser L, Kneist S, Araujo R, Contreras N, Goroncy-Bermes P, O'Mullane D, Burke F, Forde A, O'Sullivan M, Marsh PD. Microbiological evaluation of dental unit water systems in general dental practice in Europe. Eur J Oral Sci 2004; 112:412-8. [PMID: 15458499 DOI: 10.1111/j.1600-0722.2004.00151.x] [Citation(s) in RCA: 76] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
A range of opportunistic pathogens have been associated with dental unit water systems (DUWS), particularly in the biofilms that can line the tubing. This study therefore aimed to assess the microbiology of DUWS and biofilms in general dental practices across seven European countries, including the United Kingdom (UK), Ireland (IRL), Greece (GR), Spain (ES), Germany (D), Denmark (DK) and the Netherlands (NL). Water supplied by 51% of 237 dental unit water lines exceeded current American Dental Association recommendations of < or = 200 colony-forming units (CFU) ml(-1). Microbiological loading of the source waters was between 0 (Denmark, the Netherlands and Spain) and 4.67 (IRL) log CFU ml(-1); water line samples from the DUWS ranged from 1.52 (ES) to 2.79 (GR) log CFU ml(-1); and biofilm counts ranged from 1.49 (GR) to 3.22 (DK) log CFU.cm(-2). Opportunistic pathogens such as legionellae (DK and ES), including Legionella pneumophila SG1 (DK and GR), and Mycobacterium spp. (DK, NL, GR, D and ES) were recovered occasionally. Presumptive oral streptococci (ES and NL), oral anaerobes (GR), Candida spp. (UK, NL and ES) and blood (GR and IRL) were detected at relatively low frequencies, but their presence indicated a failure of the 3-in-1 antiretraction valve, leading to back siphonage of oral fluids into the water and biofilm phase. These findings confirm that a substantial proportion of DUWS have high levels of microbial contamination, irrespective of country, type of equipment and source water. The study emphasizes the need for effective mechanisms to reduce the microbial burden within DUWS, and highlights the risk of occupational exposure and cross-infection in general dental practice.
Collapse
Affiliation(s)
- J T Walker
- Health Protection Agency, Porton Down, Salisbury, UK
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
48
|
Montebugnoli L, Chersoni S, Prati C, Dolci G. A between-patient disinfection method to control water line contamination and biofilm inside dental units. J Hosp Infect 2004; 56:297-304. [PMID: 15066741 DOI: 10.1016/j.jhin.2004.01.015] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2003] [Accepted: 12/16/2003] [Indexed: 11/23/2022]
Abstract
The aim of the present study was to evaluate the efficacy of a between-patient disinfection procedures to maintain low bacterial counts in dental unit water line (DUWL) effluents, and control dental water line biofilms. Six dental units already in use, that had never been cleaned, were monitored for three weeks. During the first week only baseline contamination levels were assessed with no treatment of the system. In the second week lines were flushed with water for 30 s before treating each patient. During the third week, a disinfection procedure with 0.26% peracetic acid, followed by a water flush, was implemented before treating each patient. DUWL samples were collected both at the beginning and at the end of 216 dental procedures (72 during each period), plated on R2A agar and incubated at room temperature for seven days to obtain total bacterial counts in colony forming units per millilitre. To assess biofilm control, nine dental units (five never used and four old dental units with established biofilm) were used for 30 days in routine dental practice undergoing five between-patient DUWL disinfecting cycles every day. Water line samples were removed at baseline and at the end of the study and examined by scanning electron microscopy to determine the presence or absence of biofilms. A significant difference (P < 0.01) in mean DUWL bacterial counts was found between the three sets of observations. Biofilms were not present in any of the new dental units and a demonstrable reduction in the biofilms from the four dental units with previous presence of established biofilms was observed at the end of the study. In this study, a between-patient disinfection procedure consisting of flushing DUWL with peracetic acid with use of water was efficacious in the control of both microbial contamination of dental treatment water and dental water line biofilms.
Collapse
Affiliation(s)
- L Montebugnoli
- Department of Oral Science, University of Bologna, Via S. Vitale 59, 40125 Bologna, Italy.
| | | | | | | |
Collapse
|
49
|
Yeo SH, Chua LY. Adhesion of Pseudomonas fluorescens on magnetic surfaces. Colloids Surf B Biointerfaces 2004; 36:75-80. [PMID: 15261010 DOI: 10.1016/j.colsurfb.2004.05.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2004] [Revised: 05/11/2004] [Accepted: 05/23/2004] [Indexed: 11/20/2022]
Abstract
The adhesion of Pseudomonas fluorescens (ATCC 700830) to perpendicularly polarized magnetic surfaces was recently discovered. The findings have found that the magnetic free surfaces from different magnetic polarities have different profound effects on the P. fluorescens bacterial adhesion to its surfaces. These phenomena can be explained by the surface magnetic effect, which was found to affect the surface free energy. An in situ experiment, by contrast microscopy and under static conditions, was conducted to determine the influence of magnetic surfaces, that are polarized under different external magnetizing field strengths, on bacterial adhesion. The effect of different magnetic polarities on the surface free energy has also been investigated.
Collapse
Affiliation(s)
- Swee-Hock Yeo
- School of Mechanical and Production Engineering, Nanyang Technological University, 50 Nanyang Avenue Singapore 639798, Singapore.
| | | |
Collapse
|
50
|
Weightman NC, Lines LD. Problems with the decontamination of dental handpieces and other intra-oral dental equipment in hospitals. J Hosp Infect 2004; 56:1-5. [PMID: 14706263 DOI: 10.1016/j.jhin.2003.09.006] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Dental departments within district general hospitals contain items of equipment that require decontamination between patients. Some of these items are complex and expensive, and in busy clinics, may be required in large numbers if a sterile services department (SSD) were to be used. This may result in local manual cleaning of these instruments and sterilization in non-vacuum downward displacement autoclaves within dental departments, despite some items having narrow lumens, deep recesses and cavities, which will not adequately sterilize these instruments. Infection control teams should be aware of these difficulties particularly when arranging satisfactory infection control and decontamination procedures in hospital dental departments.
Collapse
Affiliation(s)
- N C Weightman
- Department of Microbiology, Friarage Hospital, Northallerton, North Yorkshire DL6 1JG, UK.
| | | |
Collapse
|