1
|
Mergen B, Sideroudi H, Seitz B, Flockerzi E. Altered Corneal Biomechanics According to the Biomechanical E-Staging in Pellucid Marginal Degeneration. Cornea 2024; 43:1361-1367. [PMID: 38334467 DOI: 10.1097/ico.0000000000003479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Accepted: 12/03/2023] [Indexed: 02/10/2024]
Abstract
PURPOSE The purpose of this study was to investigate corneal biomechanics in pellucid marginal degeneration (PMD) compared with healthy controls using Corvis ST (Oculus, Germany) by using the new biomechanical E-staging (based on the Corvis Biomechanical Factor, the linearized Corvis Biomechanical Index) together with tomographic parameters. METHODS Corneal biomechanical and topographic data of 75 eyes of 75 patients with PMD and 75 eyes of 75 age-matched and sex-matched healthy controls were investigated. Topographic parameters (K1, K2, Kmax, central corneal thickness (CCT), and Belin/Ambrósio Deviation Index (BAD-D) were evaluated in dependence of and correlated with the biomechanically defined E-stages. Biomechanical parameters were also recorded for the 2 groups. RESULTS Patients with PMD showed higher K2, Kmax, BAD-D, and Corvis Biomechanical Factor values and a lower CCT compared with healthy controls ( P < 0.001). The E-stage was positively correlated with K1, K2, Kmax, BAD-D, and intraocular pressure difference and negatively correlated with CCT. Stage-dependent analysis revealed a significant increase in K1, K2, Kmax ( P < 0.001), and BAD-D ( P = 0.041) in stage E3 compared with E0 and a significant decrease in stage E2 in CCT ( P = 0.009) compared with E0. CONCLUSIONS This study showed that patients with PMD may have a reduced corneal stiffness compared with healthy controls which worsens with increasing E-stage. Significant changes in topographic parameters were observed at stage E2 for CCT and at stage E3 for K1, K2, Kmax, and BAD-D when compared with stage E0.
Collapse
Affiliation(s)
- Burak Mergen
- Department of Ophthalmology, Saarland University Medical Center (UKS), Homburg/Saar, Germany; and
- Department of Ophthalmology, University of Health Sciences, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey
| | - Haris Sideroudi
- Department of Ophthalmology, Saarland University Medical Center (UKS), Homburg/Saar, Germany; and
| | - Berthold Seitz
- Department of Ophthalmology, Saarland University Medical Center (UKS), Homburg/Saar, Germany; and
| | - Elias Flockerzi
- Department of Ophthalmology, Saarland University Medical Center (UKS), Homburg/Saar, Germany; and
| |
Collapse
|
2
|
Gadamer AM, Miklaszewski P, Janiszewska-Bil D, Lyssek-Boroń A, Dobrowolski D, Wylęgała E, Grabarek BO, Kiełbasińska A, Krysik K. Assessment of OCT and Angio-OCT Parameters in Keratoconus Patients with and without Penetrating Keratoplasty. J Clin Med 2024; 13:5111. [PMID: 39274324 PMCID: PMC11395951 DOI: 10.3390/jcm13175111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2024] [Revised: 08/19/2024] [Accepted: 08/27/2024] [Indexed: 09/16/2024] Open
Abstract
Background/Objectives: Keratoconus (KC) is a bilateral eye disease characterized by corneal thinning and cone-like deformation, leading to visual impairment. This study evaluated the radial peripapillary capillaries (RPCs) in keratoconus patients with and without penetrating keratoplasty (PKP) using OCT and angio-OCT, comparing the results to a control group. Methods: This retrospective study included 149 eyes, 97 from patients who underwent PKP between January 2018 and February 2023 and 52 from patients who did not undergo PKP. The control group comprised 72 patients (144 eyes) who were healthy volunteers. Measurements included the best corrected visual acuity (BCVA), the intraocular pressure (IOP), slit-lamp biomicroscopy, a fundus examination, and corneal topography, as well as OCT and angio-OCT assessments of the RPCs, retinal nerve fiber layer (RNFL), ganglion cell complex (GCC), and central retinal thickness (CRT). Statistical analyses were performed using Student's t-test and Pearson's correlation coefficient. Results: The RNFL was significantly thinner in KC eyes after PKP compared to control eyes (p < 0.001), and the CRT was significantly thicker in KC eyes after PKP compared to control eyes (p = 0.003). However, the GCC was similar across the groups (p = 0.0885). Additionally, RPCs inside the disc were significantly reduced in KC eyes after PKP compared to control eyes (p < 0.0001). A significant positive correlation was found between RPC whole vessel density and RNFL thickness as measured via angio-OCT (r = 0.308, p < 0.0001). Conclusions: This study found that the RPC density inside the disc is significantly reduced in keratoconus patients after penetrating keratoplasty, highlighting RPCs inside the disc as a potential diagnostic tool for further assessment of keratoconus.
Collapse
Affiliation(s)
- Anna Maria Gadamer
- Department of Ophthalmology, St. Barbara Hospital, Trauma Centre, 41-200 Sosnowiec, Poland
- Department of Ophthalmology, Faculty of Medicine, Academy of Silesia, 40-555 Katowice, Poland
| | - Piotr Miklaszewski
- Department of Ophthalmology, St. Barbara Hospital, Trauma Centre, 41-200 Sosnowiec, Poland
- Department of Ophthalmology, Faculty of Medicine, Academy of Silesia, 40-555 Katowice, Poland
| | - Dominika Janiszewska-Bil
- Department of Ophthalmology, St. Barbara Hospital, Trauma Centre, 41-200 Sosnowiec, Poland
- Collegium Medicum, WSB University, 41-300 Dabrowa Gornicza, Poland
| | - Anita Lyssek-Boroń
- Department of Ophthalmology, St. Barbara Hospital, Trauma Centre, 41-200 Sosnowiec, Poland
- Department of Ophthalmology, Faculty of Medicine, Academy of Silesia, 40-555 Katowice, Poland
| | - Dariusz Dobrowolski
- Department of Ophthalmology, St. Barbara Hospital, Trauma Centre, 41-200 Sosnowiec, Poland
- Department of Ophthalmology, District Railway Hospital, 40-760 Katowice, Poland
- Department of Ophthalmology, Faculty of Medicine, Medical University of Silesia, 40-555 Katowice, Poland
| | - Edward Wylęgała
- Department of Ophthalmology, District Railway Hospital, 40-760 Katowice, Poland
- Department of Ophthalmology, Faculty of Medicine, Medical University of Silesia, 40-555 Katowice, Poland
| | | | | | - Katarzyna Krysik
- Department of Ophthalmology, St. Barbara Hospital, Trauma Centre, 41-200 Sosnowiec, Poland
- Department of Ophthalmology, Faculty of Medicine, Academy of Silesia, 40-555 Katowice, Poland
| |
Collapse
|
3
|
Berger T, Flockerzi E, Berger M, Chai N, Stachon T, Szentmáry N, Seitz B. Expression of matrix metalloproteinases and their inhibitors in corneal stromal fibroblasts and keratocytes from healthy and keratoconus corneas. Graefes Arch Clin Exp Ophthalmol 2024:10.1007/s00417-024-06601-y. [PMID: 39177803 DOI: 10.1007/s00417-024-06601-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 07/20/2024] [Accepted: 07/26/2024] [Indexed: 08/24/2024] Open
Abstract
PURPOSE To examine the in-vitro expression of matrix metalloproteinases (MMP) and tissue inhibitors of metalloproteinases (TIMP) in corneal stromal cells by distinguishing between fibroblasts and keratocytes of healthy and keratoconus (KC) corneas. METHODS Stromal cells were isolated from healthy and KC corneas (n = 8). A normal-glucose, serum-containing cell culture medium (NGSC-medium) was used for cultivation of healthy human corneal fibroblasts (HCFs) and KC human corneal fibroblasts (KC-HCFs). In order to obtain a keratocyte phenotype, the initial cultivation with NGSC-medium was changed to a low-glucose, serum-free cell culture medium for healthy (Keratocytes) and KC cells (KC-Keratocytes). Gene and protein expression of MMP-1, -2, -3, -7, -9 and TIMP-1, -2, -3 were measured by quantitative PCR and Enzyme-Linked Immunosorbent Assay (ELISA) from the cell culture supernatant. RESULTS KC-HCFs demonstrated a lower mRNA gene expression for MMP-2 compared to HCFs. In contrast to their respective fibroblast groups (either HCFs or KC-HCFs), Keratocytes showed a higher mRNA gene expression of TIMP-3, whereas TIMP-1 mRNA gene expression was lower in Keratocytes and KC-Keratocytes. Protein analysis of the cell culture supernatant revealed lower concentrations of MMP-1 in KC-HCFs compared to HCFs. Compared to Keratocytes, TIMP-1 concentrations was lower in the cell culture supernatant of KC-Keratocytes. In HCFs and KC-HCFs, protein levels of MMP-1 and TIMP-1 were higher and MMP-2 was lower compared to Keratocytes and KC-Keratocytes, respectively. CONCLUSION This study indicates an imbalance in MMP and TIMP expression between healthy and diseased cells. Furthermore, differences in the expression of MMPs and TIMPs exist between corneal fibroblasts and keratocytes, which could influence the specific proteolytic metabolism in-vivo and contribute to the progression of KC.
Collapse
Affiliation(s)
- Tim Berger
- Department of Ophthalmology, Saarland University Medical Center, Homburg/Saar, Germany.
| | - Elias Flockerzi
- Department of Ophthalmology, Saarland University Medical Center, Homburg/Saar, Germany
| | - Maximilian Berger
- Department of Ophthalmology, Saarland University Medical Center, Homburg/Saar, Germany
| | - Ning Chai
- Dr. Rolf M. Schwiete Center for Limbal Stem Cell and Congenital Aniridia Research, Saarland University, Homburg/Saar, Germany
| | - Tanja Stachon
- Dr. Rolf M. Schwiete Center for Limbal Stem Cell and Congenital Aniridia Research, Saarland University, Homburg/Saar, Germany
| | - Nóra Szentmáry
- Dr. Rolf M. Schwiete Center for Limbal Stem Cell and Congenital Aniridia Research, Saarland University, Homburg/Saar, Germany
| | - Berthold Seitz
- Department of Ophthalmology, Saarland University Medical Center, Homburg/Saar, Germany
| |
Collapse
|
4
|
Kanellopoulos AJ, Kanellopoulos AJ. Topographic Keratoconus Incidence in Greece Diagnosed in Routine Consecutive Cataract Procedures: A Consecutive Case Series of 1250 Cases over 5 Years. J Clin Med 2024; 13:2378. [PMID: 38673651 PMCID: PMC11051409 DOI: 10.3390/jcm13082378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Revised: 04/11/2024] [Accepted: 04/15/2024] [Indexed: 04/28/2024] Open
Abstract
Background: Scheimpflug tomography has for many years been an integral part of our pre-operative assessment in cataract extraction. We retrospectively reviewed the incidence of topographic keratoconus and keratoconus suspicion in our routine cataract surgery population over 5 years. Setting: The Laservision Clinical and Research Institute, Athens, Greece. Methods: In 1250 consecutive cataract surgery cases in otherwise naïve eyes, accounting for years 2017 to 2021, we retrospectively evaluated preoperative Pentacam HR imaging. The cases already classified as keratoconus were included in group A. The residual cases were assessed by five different experienced evaluators (two ophthalmic surgeons and three optometrists) for topographic and tomographic keratoconus suspicion based on irregular pachymetry distribution, astigmatism truncation, and/or astigmatic imaging irregularity and included in group B. Regular corneas, by this assessment, were included in group C; irregular corneas, as determined by the evaluators but unrelated to keratoconus, were included in group D. Results: Based on the above, 138 cases (11.08%) were classified by Pentacam tomography as keratoconus and by default were included in group A. Of the residual cases, 314 or 25.12% were classified as suspect keratoconus and included in group B; 725 cases (58%) were classified as normal and non-keratoconus and included in group C; and 73 cases or 5.84% were placed in group D as non-keratoconus but abnormal. There was no disagreement between the five evaluators over any of the cases in groups C and D, and little variance among them for cases included in group B (less than 5% by ANOVA). Conclusions: The incidence of keratoconus and corneas suspicious for keratoconus in Greece appears to be much higher than respective reports from other regions: one in ten Greeks appear to have topographic keratoconus, most not diagnosed even by the age of cataract surgery, and almost an additional one in four may have suspicious corneal imaging for keratoconus. These data strongly imply that routine screening for disease should be promoted among Greeks, especially during puberty, to halt possible progression; moreover, careful screening should be performed when laser vision correction is being considered.
Collapse
Affiliation(s)
- Anastasios John Kanellopoulos
- Ophthalmology Department, LaserVision Ambulatory Eye Surgery Unit, 115 21 Athens, Greece;
- Ophthalmology Department, NYU Grossman Med School, New York, NY 10016, USA
| | - Alexander J. Kanellopoulos
- Ophthalmology Department, LaserVision Ambulatory Eye Surgery Unit, 115 21 Athens, Greece;
- School of Medicine, European University Cyprus, Engomi, Nicosia 2404, Cyprus
| |
Collapse
|
5
|
Erdinest N, London N, Landau D, Barbara R, Barbara A, Naroo SA. Higher order aberrations in keratoconus. Int Ophthalmol 2024; 44:172. [PMID: 38594548 DOI: 10.1007/s10792-024-03118-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Accepted: 03/24/2024] [Indexed: 04/11/2024]
Abstract
INTRODUCTION Keratoconus is a progressive disorder of the cornea that causes thinning (Sedaghat et al. in Sci Rep 11(1):11971, 2021), ectasia, and irregular astigmatism, resulting in poor visual acuity that cannot be corrected with standard sphero-cylindrical spectacle lenses. One feature distinguishing keratoconic corneas is ocular aberrations, manifesting up to five or six times the amount of higher-order aberrations than a normal, healthy eye. These aberrations can cause visual disturbances even at the very early stages of the disease. METHODS In the past, a diagnosis was derived from clinical symptoms, but technological advances have revealed multiple pre-clinical features, allowing for the differentiation between keratoconic and normal eyes at a much earlier stage. These include anterior and posterior corneal surface elevations, the corneal pachymetry profile, corneal epithelial patterns, wavefront aberration metrics, and corneal biomechanics (Sedaghat et al. in Sci Rep 11(1):11971, 2021).This review discusses the aberrations associated with keratoconus, how to measure them, and treatment methods to minimize their negative influence. CONCLUSIONS Early diagnosis can lead to early treatment and may allow for arresting progression, thereby improving the long-term prognosis. With the acceleration of refractive surgery, it is important to identify patients with keratoconus, as they are usually contraindicated for refractive surgery.
Collapse
Affiliation(s)
- Nir Erdinest
- Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem, Israel
| | | | - David Landau
- Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem, Israel
| | - Ramez Barbara
- Ophthalmology Department, University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - Adel Barbara
- IVISION Cornea and Refractive Surgery Center, Haifa, Israel
| | - Shehzad A Naroo
- College of Health and Life Sciences, Aston University, Birmingham, UK
| |
Collapse
|