1
|
Chang HF, Cheng JY. Glioblastoma U-87 cell electrotaxis is hindered by doxycycline with a concomitant reduction in the matrix metallopeptidase-9 expression. Biochem Biophys Rep 2024; 38:101690. [PMID: 38571555 PMCID: PMC10987802 DOI: 10.1016/j.bbrep.2024.101690] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 03/15/2024] [Accepted: 03/19/2024] [Indexed: 04/05/2024] Open
Abstract
Electric fields (EF) play an essential role in cancer cell migration. Numerous cancer cell types exhibit electrotaxis under direct current electric fields (dcEF) of physiological electric field strength (EFs). This study investigated the effects of doxycycline on the electrotactic responses of U87 cells. After EF stimulation, U87 cells migrated toward the cathode, whereas doxycycline-treated U87 cells exhibited enhanced cell mobility but hindered cathodal migration. We further investigated the expression of the metastasis-correlated proteins matrix metallopeptidase-2 (MMP-2) and MMP-9 in U87 cells. The levels of MMP-2 in the cells were not altered under EF or doxycycline stimulation. In contrast, the EF stimulation greatly enhanced the levels of MMP-9 and then repressed in doxycycline-cotreated cells, accompanied by reduced cathodal migration. Our results demonstrated that an antibiotic at a non-toxic concentration could suppress the enhanced cell migration accelerated by EF of physiological strength. This finding may be applied as an anti-metastatic treatment for cancers.
Collapse
Affiliation(s)
- Hui-Fang Chang
- Research Center for Applied Sciences, Academia Sinica, Taipei, Taiwan
| | - Ji-Yen Cheng
- Research Center for Applied Sciences, Academia Sinica, Taipei, Taiwan
- Institute of Biophotonics, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Department of Mechanical and Mechatronic Engineering, National Taiwan Ocean University, Keelung, Taiwan
- College of Engineering, Chang Gung University, Taoyuan, Taiwan
| |
Collapse
|
2
|
Moarefian M, Davalos RV, Burton MD, Jones CN. Electrotaxis-on-Chip to Quantify Neutrophil Migration Towards Electrochemical Gradients. Front Immunol 2021; 12:674727. [PMID: 34421891 PMCID: PMC8379007 DOI: 10.3389/fimmu.2021.674727] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Accepted: 07/12/2021] [Indexed: 11/21/2022] Open
Abstract
Electric fields are generated in vivo in a variety of physiologic and pathologic settings, including wound healing and immune response to injuries to epithelial barriers (e.g. lung pneumocytes). Immune cells are known to migrate towards both chemical (chemotaxis), physical (mechanotaxis) and electric stimuli (electrotaxis). Electrotaxis is the guided migration of cells along electric fields, and has previously been reported in T-cells and cancer cells. However, there remains a need for engineering tools with high spatial and temporal resolution to quantify EF guided migration. Here we report the development of an electrotaxis-on-chip (ETOC) platform that enables the quantification of dHL-60 cell, a model neutrophil-like cell line, migration toward both electrical and chemoattractant gradients. Neutrophils are the most abundant white blood cells and set the stage for the magnitude of the immune response. Therefore, developing engineering tools to direct neutrophil migration patterns has applications in both infectious disease and inflammatory disorders. The ETOC developed in this study has embedded electrodes and four migration zones connected to a central cell-loading chamber with migration channels [10 µm X 10 µm]. This device enables both parallel and competing chemoattractant and electric fields. We use our novel ETOC platform to investigate dHL-60 cell migration in three biologically relevant conditions: 1) in a DC electric field; 2) parallel chemical gradient and electric fields; and 3) perpendicular chemical gradient and electric field. In this study we used differentiated leukemia cancer cells (dHL60 cells), an accepted model for human peripheral blood neutrophils. We first quantified effects of electric field intensities (0.4V/cm-1V/cm) on dHL-60 cell electrotaxis. Our results show optimal migration at 0.6 V/cm. In the second scenario, we tested whether it was possible to increase dHL-60 cell migration to a bacterial signal [N-formylated peptides (fMLP)] by adding a parallel electric field. Our results show that there was significant increase (6-fold increase) in dHL60 migration toward fMLP and cathode of DC electric field (0.6V/cm, n=4, p-value<0.005) vs. fMLP alone. Finally, we evaluated whether we could decrease or re-direct dHL-60 cell migration away from an inflammatory signal [leukotriene B4 (LTB4)]. The perpendicular electric field significantly decreased migration (2.9-fold decrease) of dHL60s toward LTB4vs. LTB4 alone. Our microfluidic device enabled us to quantify single-cell electrotaxis velocity (7.9 µm/min ± 3.6). The magnitude and direction of the electric field can be more precisely and quickly changed than most other guidance cues such as chemical cues in clinical investigation. A better understanding of EF guided cell migration will enable the development of new EF-based treatments to precisely direct immune cell migration for wound care, infection, and other inflammatory disorders.
Collapse
Affiliation(s)
- Maryam Moarefian
- Department of Biological Sciences, Virginia Tech, Blacksburg, VA, United States
| | - Rafael V. Davalos
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA, United States
| | - Michael D. Burton
- Department of Neuroscience, Neuroimmunology and Behavior Group, School of Behavioral and Brain Sciences, University of Texas at Dallas, Richardson, TX, United States
| | - Caroline N. Jones
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX, United States
| |
Collapse
|
3
|
Lin FY, Lin JY, Lo KY, Sun YS. Use Microfluidic Chips to Study the Phototaxis of Lung Cancer Cells. Int J Mol Sci 2019; 20:ijms20184515. [PMID: 31547262 PMCID: PMC6769873 DOI: 10.3390/ijms20184515] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2019] [Revised: 09/02/2019] [Accepted: 09/10/2019] [Indexed: 01/09/2023] Open
Abstract
Cell migration is an important process involved in wound healing, tissue development, and so on. Many studies have been conducted to explore how certain chemicals and electric fields induce cell movements in specific directions, which are phenomena termed chemotaxis and electrotaxis, respectively. However, phototaxis, the directional migration of cells or organisms toward or away from light, is rarely investigated due to the difficulty of generating a precise and controllable light gradient. In this study, we designed and fabricated a microfluidic chip for simultaneously culturing cells and generating a blue light gradient for guiding cell migration. A concentration gradient was first established inside this chip, and by illuminating it with a blue light-emitting diode (LED), a blue light gradient was generated underneath. Cell migration in response to this light stimulus was observed. It was found that lung cancer cells migrated to the dark side of the gradient, and the intracellular reactive oxygen species (ROS) was proportional to the intensity of the blue light.
Collapse
Affiliation(s)
- Fong-Yi Lin
- Department of Physics, Fu-Jen Catholic University, New Taipei City 24205, Taiwan.
| | - Jin-Young Lin
- Department of Physics, Fu-Jen Catholic University, New Taipei City 24205, Taiwan.
| | - Kai-Yin Lo
- Department of Agricultural Chemistry, National Taiwan University, Taipei 10617, Taiwan.
| | - Yung-Shin Sun
- Department of Physics, Fu-Jen Catholic University, New Taipei City 24205, Taiwan.
| |
Collapse
|
4
|
Ruzycka M, Cimpan MR, Rios-Mondragon I, Grudzinski IP. Microfluidics for studying metastatic patterns of lung cancer. J Nanobiotechnology 2019; 17:71. [PMID: 31133019 PMCID: PMC6537392 DOI: 10.1186/s12951-019-0492-0] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Accepted: 05/04/2019] [Indexed: 01/09/2023] Open
Abstract
The incidence of lung cancer continues to rise worldwide. Because the aggressive metastasis of lung cancer cells is the major drawback of successful therapies, the crucial challenge of modern nanomedicine is to develop diagnostic tools to map the molecular mechanisms of metastasis in lung cancer patients. In recent years, microfluidic platforms have been given much attention as tools for novel point-of-care diagnostic, an important aspect being the reconstruction of the body organs and tissues mimicking the in vivo conditions in one simple microdevice. Herein, we present the first comprehensive overview of the microfluidic systems used as innovative tools in the studies of lung cancer metastasis including single cancer cell analysis, endothelial transmigration, distant niches migration and finally neoangiogenesis. The application of the microfluidic systems to study the intercellular crosstalk between lung cancer cells and surrounding tumor microenvironment and the connection with multiple molecular signals coming from the external cellular matrix are discussed. We also focus on recent breakthrough technologies regarding lab-on-chip devices that serve as tools for detecting circulating lung cancer cells. The superiority of microfluidic systems over traditional in vitro cell-based assays with regard to modern nanosafety studies and new cancer drug design and discovery is also addressed. Finally, the current progress and future challenges regarding printable and paper-based microfluidic devices for personalized nanomedicine are summarized.
Collapse
Affiliation(s)
- Monika Ruzycka
- Department of Applied Toxicology, Faculty of Pharmacy, Medical University of Warsaw, 1 Banacha Street, 02-097, Warsaw, Poland
| | - Mihaela R Cimpan
- Biomaterials - Department for Clinical Dentistry, University of Bergen, Årstadveien 19, 5009, Bergen, Norway
| | - Ivan Rios-Mondragon
- Biomaterials - Department for Clinical Dentistry, University of Bergen, Årstadveien 19, 5009, Bergen, Norway
| | - Ireneusz P Grudzinski
- Department of Applied Toxicology, Faculty of Pharmacy, Medical University of Warsaw, 1 Banacha Street, 02-097, Warsaw, Poland.
| |
Collapse
|
5
|
Shang M, Soon RH, Lim CT, Khoo BL, Han J. Microfluidic modelling of the tumor microenvironment for anti-cancer drug development. LAB ON A CHIP 2019; 19:369-386. [PMID: 30644496 DOI: 10.1039/c8lc00970h] [Citation(s) in RCA: 144] [Impact Index Per Article: 28.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Cancer is the leading cause of death worldwide. The complex and disorganized tumor microenvironment makes it very difficult to treat this disease. The most common in vitro drug screening method now is based on 2D culture models which poorly represent actual tumors. Therefore, many 3D tumor models which are more physiologically relevant have been developed to conduct in vitro drug screening and alleviate this situation. Among all these models, the microfluidic tumor model has the unique advantage of recapitulating the tumor microenvironment in a comparatively easier and representative fashion. While there are many review papers available on the related topic of microfluidic tumor models, in this review we aim to focus more on the possibility of generating "clinically actionable information" from these microfluidic systems, besides scientific insight. Our topics cover the tumor microenvironment, conventional 2D and 3D cultures, animal models, and microfluidic tumor models, emphasizing their link to anti-cancer drug discovery and personalized medicine.
Collapse
Affiliation(s)
- Menglin Shang
- BioSystems and Micromechanics (BioSyM) IRG, Singapore-MIT Alliance for Research and Technology (SMART) Centre, 1, Create Way, Enterprise Wing, 138602, Singapore.
| | | | | | | | | |
Collapse
|
6
|
Mishra S, Vazquez M. A Gal-MµS Device to Evaluate Cell Migratory Response to Combined Galvano-Chemotactic Fields. BIOSENSORS-BASEL 2017; 7:bios7040054. [PMID: 29160793 PMCID: PMC5746777 DOI: 10.3390/bios7040054] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2017] [Revised: 11/15/2017] [Accepted: 11/16/2017] [Indexed: 01/10/2023]
Abstract
Electric fields have been studied extensively in biomedical engineering (BME) for numerous regenerative therapies. Recent studies have begun to examine the biological effects of electric fields in combination with other environmental cues, such as tissue-engineered extracellular matrices (ECM), chemical gradient profiles, and time-dependent temperature gradients. In the nervous system, cell migration driven by electrical fields, or galvanotaxis, has been most recently studied in transcranial direct stimulation (TCDS), spinal cord repair and tumor treating fields (TTF). The cell migratory response to galvano-combinatory fields, such as magnetic fields, chemical gradients, or heat shock, has only recently been explored. In the visual system, restoration of vision via cellular replacement therapies has been limited by low numbers of motile cells post-transplantation. Here, the combinatory application of electrical fields with other stimuli to direct cells within transplantable biomaterials and/or host tissues has been understudied. In this work, we developed the Gal-MµS device, a novel microfluidics device capable of examining cell migratory behavior in response to single and combinatory stimuli of electrical and chemical fields. The formation of steady-state, chemical concentration gradients and electrical fields within the Gal-MµS were modeled computationally and verified experimentally within devices fabricated via soft lithography. Further, we utilized real-time imaging within the device to capture cell trajectories in response to electric fields and chemical gradients, individually, as well as in combinatory fields of both. Our data demonstrated that neural cells migrated longer distances and with higher velocities in response to combined galvanic and chemical stimuli than to either field individually, implicating cooperative behavior. These results reveal a biological response to galvano-chemotactic fields that is only partially understood, as well as point towards novel migration-targeted treatments to improve cell-based regenerative therapies.
Collapse
Affiliation(s)
- Shawn Mishra
- Department of Biomedical Engineering, City College of New York, New York, NY 10031, USA.
| | - Maribel Vazquez
- Department of Biomedical Engineering, City College of New York, New York, NY 10031, USA.
| |
Collapse
|
7
|
Sun YS. Studying Electrotaxis in Microfluidic Devices. SENSORS (BASEL, SWITZERLAND) 2017; 17:E2048. [PMID: 28880251 PMCID: PMC5621068 DOI: 10.3390/s17092048] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/11/2017] [Revised: 09/05/2017] [Accepted: 09/05/2017] [Indexed: 12/11/2022]
Abstract
Collective cell migration is important in various physiological processes such as morphogenesis, cancer metastasis and cell regeneration. Such migration can be induced and guided by different chemical and physical cues. Electrotaxis, referring to the directional migration of adherent cells under stimulus of electric fields, is believed to be highly involved in the wound-healing process. Electrotactic experiments are conventionally conducted in Petri dishes or cover glasses wherein cells are cultured and electric fields are applied. However, these devices suffer from evaporation of the culture medium, non-uniformity of electric fields and low throughput. To overcome these drawbacks, micro-fabricated devices composed of micro-channels and fluidic components have lately been applied to electrotactic studies. Microfluidic devices are capable of providing cells with a precise micro-environment including pH, nutrition, temperature and various stimuli. Therefore, with the advantages of reduced cell/reagent consumption, reduced Joule heating and uniform and precise electric fields, microfluidic chips are perfect platforms for observing cell migration under applied electric fields. In this paper, I review recent developments in designing and fabricating microfluidic devices for studying electrotaxis, aiming to provide critical updates in this rapidly-growing, interdisciplinary field.
Collapse
Affiliation(s)
- Yung-Shin Sun
- Department of Physics, Fu-Jen Catholic University, New Taipei City 24205, Taiwan.
| |
Collapse
|
8
|
Li Y, Xu T, Chen X, Lin S, Cho M, Sun D, Yang M. Effects of direct current electric fields on lung cancer cell electrotaxis in a PMMA-based microfluidic device. Anal Bioanal Chem 2017; 409:2163-2178. [DOI: 10.1007/s00216-016-0162-0] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2016] [Revised: 12/14/2016] [Accepted: 12/16/2016] [Indexed: 11/27/2022]
|
9
|
Li Y, Xu T, Zou H, Chen X, Sun D, Yang M. Cell migration microfluidics for electrotaxis-based heterogeneity study of lung cancer cells. Biosens Bioelectron 2016; 89:837-845. [PMID: 27816579 DOI: 10.1016/j.bios.2016.10.002] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2016] [Revised: 09/30/2016] [Accepted: 10/03/2016] [Indexed: 01/17/2023]
Abstract
Tumor metastasis involves the migration of cells from primary site to a distant location. Recently, it was established that cancer cells from the same tumor were heterogeneous in migratory ability. Numerous studies have demonstrated that cancer cells undergo reorientation and migration directionally under physiological electric field (EF), which has potential implications in metastasis. Microfluidic devices with channel structures of defined dimensions provide controllable microenvironments to enable real-time observation of cell migration. In this study, we developed two polydimethylsiloxane (PDMS)-based microfluidic devices for long-term electrotaxis study. In the first chip, three different intensities of EFs were generated in a single channel to study cell electrotactic behavior with high efficiency. We observed that the lung adenocarcinoma H1975 cells underwent cathodal migration with changing cellular orientation. To address the issue of cell electrotactic heterogeneity, we also developed a cell isolation device integrating cell immobilization structure, stable EF generator and cell retrieval module in one microfluidic chip to sort out different cell subpopulations based on electrotactic ability. High electrotactic and low electrotactic cells were harvested separately for colony formation assay and transcriptional analysis of migration-related genes. The results showed that H1975 cell motility was related to EGFR expression in the absence of EF stimulation, while in the presence of EF it was associated with PTEN expression. Up-regulation of RhoA was observed in cells with high motility, regardless of EF. The easy cell manipulation and precise field control of the microfluidic devices may enable further study of tumor heterogeneity in complex electrotactic environments.
Collapse
Affiliation(s)
- Yaping Li
- Department of Biomedical Sciences, City University of Hong Kong, Hong Kong, China; Key Laboratory of Biochip Technology, Biotech and Health Centre, Shenzhen, Research Institutes of City University of Hong Kong, Shenzhen, China
| | - Tao Xu
- Department of Biomedical Sciences, City University of Hong Kong, Hong Kong, China; Liaoning Medical University, Jinzhou, Liaoning, China
| | - Heng Zou
- Department of Biomedical Sciences, City University of Hong Kong, Hong Kong, China; Key Laboratory of Biochip Technology, Biotech and Health Centre, Shenzhen, Research Institutes of City University of Hong Kong, Shenzhen, China
| | - Xiaomei Chen
- Key Laboratory of Biochip Technology, Biotech and Health Centre, Shenzhen, Research Institutes of City University of Hong Kong, Shenzhen, China
| | - Dong Sun
- Department of Mechanical and Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Mengsu Yang
- Department of Biomedical Sciences, City University of Hong Kong, Hong Kong, China; Key Laboratory of Biochip Technology, Biotech and Health Centre, Shenzhen, Research Institutes of City University of Hong Kong, Shenzhen, China.
| |
Collapse
|
10
|
Chou TY, Sun YS, Hou HS, Wu SY, Zhu Y, Cheng JY, Lo KY. Designing Microfluidic Devices for Studying Cellular Responses Under Single or Coexisting Chemical/Electrical/Shear Stress Stimuli. J Vis Exp 2016. [PMID: 27584698 DOI: 10.3791/54397] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Microfluidic devices are capable of creating a precise and controllable cellular micro-environment of pH, temperature, salt concentration, and other physical or chemical stimuli. They have been commonly used for in vitro cell studies by providing in vivo like surroundings. Especially, how cells response to chemical gradients, electrical fields, and shear stresses has drawn many interests since these phenomena are important in understanding cellular properties and functions. These microfluidic chips can be made of glass substrates, silicon wafers, polydimethylsiloxane (PDMS) polymers, polymethylmethacrylate (PMMA) substrates, or polyethyleneterephthalate (PET) substrates. Out of these materials, PMMA substrates are cheap and can be easily processed using laser ablation and writing. Although a few microfluidic devices have been designed and fabricated for generating multiple, coexisting chemical and electrical stimuli, none of them was considered efficient enough in reducing experimental repeats, particular for screening purposes. In this report, we describe our design and fabrication of two PMMA-based microfluidic chips for investigating cellular responses, in the production of reactive oxygen species and the migration, under single or coexisting chemical/electrical/shear stress stimuli. The first chip generates five relative concentrations of 0, 1/8, 1/2, 7/8, and 1 in the culture regions, together with a shear stress gradient produced inside each of these areas. The second chip generates the same relative concentrations, but with five different electric field strengths created within each culture area. These devices not only provide cells with a precise, controllable micro-environment but also greatly increase the experimental throughput.
Collapse
Affiliation(s)
- Tzu-Yuan Chou
- Department of Agricultural Chemistry, National Taiwan University
| | | | - Hsien-San Hou
- Research Center for Applied Sciences, Academia Sinica
| | - Shang-Ying Wu
- Department of Agricultural Chemistry, National Taiwan University
| | - Yun Zhu
- Department of Agricultural Chemistry, National Taiwan University
| | - Ji-Yen Cheng
- Research Center for Applied Sciences, Academia Sinica
| | - Kai-Yin Lo
- Department of Agricultural Chemistry, National Taiwan University;
| |
Collapse
|
11
|
Sun YS. Comparison of Chip Inlet Geometry in Microfluidic Devices for Cell Studies. Molecules 2016; 21:molecules21060778. [PMID: 27314318 PMCID: PMC6273264 DOI: 10.3390/molecules21060778] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2016] [Revised: 06/08/2016] [Accepted: 06/12/2016] [Indexed: 12/02/2022] Open
Abstract
Micro-fabricated devices integrated with fluidic components provide an in vitro platform for cell studies best mimicking the in vivo micro-environment. These devices are capable of creating precise and controllable surroundings of pH value, temperature, salt concentration, and other physical or chemical stimuli. Various cell studies such as chemotaxis and electrotaxis can be performed by using such devices. Moreover, microfluidic chips are designed and fabricated for applications in cell separations such as circulating tumor cell (CTC) chips. Usually, there are two most commonly used inlets in connecting the microfluidic chip to sample/reagent loading tubes: the vertical (top-loading) inlet and the parallel (in-line) inlet. Designing this macro-to-micro interface is believed to play an important role in device performance. In this study, by using the commercial COMSOL Multiphysics software, we compared the cell capture behavior in microfluidic devices with different inlet types and sample flow velocities. Three different inlets were constructed: the vertical inlet, the parallel inlet, and the vertically parallel inlet. We investigated the velocity field, the flow streamline, the cell capture rate, and the laminar shear stress in these inlets. It was concluded that the inlet should be designed depending on the experimental purpose, i.e., one wants to maximize or minimize cell capture. Also, although increasing the flow velocity could reduce cell sedimentation, too high shear stresses are thought harmful to cells. Our findings indicate that the inlet design and flow velocity are crucial and should be well considered in fabricating microfluidic devices for cell studies.
Collapse
Affiliation(s)
- Yung-Shin Sun
- Department of Physics, Fu-Jen Catholic University, New Taipei City 24205, Taiwan.
| |
Collapse
|
12
|
Tsai HF, Cheng JY, Chang HF, Yamamoto T, Shen AQ. Uniform electric field generation in circular multi-well culture plates using polymeric inserts. Sci Rep 2016; 6:26222. [PMID: 27193911 PMCID: PMC4872143 DOI: 10.1038/srep26222] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2015] [Accepted: 04/29/2016] [Indexed: 12/22/2022] Open
Abstract
Applying uniform electric field (EF) in vitro in the physiological range has been achieved in rectangular shaped microchannels. However, in a circular-shaped device, it is difficult to create uniform EF from two electric potentials due to different electrical resistances originated from the length difference between the diameter of the circle and the length of any parallel chord of the bottom circular chamber where cells are cultured. To address this challenge, we develop a three-dimensional (3D) computer-aided designed (CAD) polymeric insert to create uniform EF in circular shaped multi-well culture plates. A uniform EF with a coefficient of variation (CV) of 1.2% in the 6-well plate can be generated with an effective stimulation area percentage of 69.5%. In particular, NIH/3T3 mouse embryonic fibroblast cells are used to validate the performance of the 3D designed Poly(methyl methacrylate) (PMMA) inserts in a circular-shaped 6-well plate. The CAD based inserts can be easily scaled up (i.e., 100 mm dishes) to further increase effective stimulation area percentages, and also be implemented in commercially available cultureware for a wide variety of EF-related research such as EF-cell interaction and tissue regeneration studies.
Collapse
Affiliation(s)
- Hsieh-Fu Tsai
- Micro/Bio/Nanofluidics Unit, Okinawa Institute of Science and Technology Graduate University, Okinawa, 904-0495, Japan
| | - Ji-Yen Cheng
- Research Center for Applied Sciences, Academia Sinica, Taipei, 11529, Taiwan
| | - Hui-Fang Chang
- Research Center for Applied Sciences, Academia Sinica, Taipei, 11529, Taiwan
| | - Tadashi Yamamoto
- Cell Signal Unit, Okinawa Institute of Science and Technology Graduate University, Okinawa, 904-0495, Japan
| | - Amy Q Shen
- Micro/Bio/Nanofluidics Unit, Okinawa Institute of Science and Technology Graduate University, Okinawa, 904-0495, Japan
| |
Collapse
|
13
|
Microfluidic Organ/Body-on-a-Chip Devices at the Convergence of Biology and Microengineering. SENSORS 2015; 15:31142-70. [PMID: 26690442 PMCID: PMC4721768 DOI: 10.3390/s151229848] [Citation(s) in RCA: 84] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/22/2015] [Revised: 11/16/2015] [Accepted: 12/04/2015] [Indexed: 12/24/2022]
Abstract
Recent advances in biomedical technologies are mostly related to the convergence of biology with microengineering. For instance, microfluidic devices are now commonly found in most research centers, clinics and hospitals, contributing to more accurate studies and therapies as powerful tools for drug delivery, monitoring of specific analytes, and medical diagnostics. Most remarkably, integration of cellularized constructs within microengineered platforms has enabled the recapitulation of the physiological and pathological conditions of complex tissues and organs. The so-called “organ-on-a-chip” technology, which represents a new avenue in the field of advanced in vitro models, with the potential to revolutionize current approaches to drug screening and toxicology studies. This review aims to highlight recent advances of microfluidic-based devices towards a body-on-a-chip concept, exploring their technology and broad applications in the biomedical field.
Collapse
|
14
|
Hsiao YF, Pan HJ, Tung YC, Chen CC, Lee CH. Effects of hydraulic pressure on cardiomyoblasts in a microfluidic device. BIOMICROFLUIDICS 2015; 9:024111. [PMID: 25945137 PMCID: PMC4393411 DOI: 10.1063/1.4917080] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2015] [Accepted: 03/27/2015] [Indexed: 05/05/2023]
Abstract
We employed a microfluidic device to study the effects of hydraulic pressure on cardiomyoblast H9c2. The 170 mm Hg pressure increased the cellular area and the expression of atrial natriuretic peptide. With the same device, we demonstrated that the effects of hydraulic pressure on the cardiomyoblast could be reduced by the inhibitor of focal adhesion kinase. This mechanical-chemical antagonism could lead to a potential therapeutic strategy of hypertension-induced cardiac hypertrophy.
Collapse
Affiliation(s)
| | - Huei-Jyuan Pan
- Research Center for Applied Sciences , Academia Sinica, Taipei 11529, Taiwan
| | - Yi-Chung Tung
- Research Center for Applied Sciences , Academia Sinica, Taipei 11529, Taiwan
| | - Chien-Chang Chen
- Institute of Biomedical Sciences , Academia Sinica, Taipei 11529, Taiwan
| | | |
Collapse
|
15
|
Kao YC, Hsieh MH, Liu CC, Pan HJ, Liao WY, Cheng JY, Kuo PL, Lee CH. Modulating chemotaxis of lung cancer cells by using electric fields in a microfluidic device. BIOMICROFLUIDICS 2014; 8:024107. [PMID: 24738014 PMCID: PMC3976467 DOI: 10.1063/1.4870401] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/07/2014] [Accepted: 03/24/2014] [Indexed: 05/08/2023]
Abstract
We employed direct-current electric fields (dcEFs) to modulate the chemotaxis of lung cancer cells in a microfluidic cell culture device that incorporates both stable concentration gradients and dcEFs. We found that the chemotaxis induced by a 0.5 μM/mm concentration gradient of epidermal growth factor can be nearly compensated by a 360 mV/mm dcEF. When the effect of chemical stimulation was balanced by the electrical drive, the cells migrated randomly, and the path lengths were largely reduced. We also demonstrated electrically modulated chemotaxis of two types of lung cancer cells with opposite directions of electrotaxis in this device.
Collapse
Affiliation(s)
- Yu-Chiu Kao
- Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei 10617, Taiwan ; Research Center for Applied Sciences, Academia Sinica, 11529 Taipei, Taiwan
| | - Meng-Hua Hsieh
- Institute of Biophotonics, National Yang-Ming University, 11221 Taipei, Taiwan ; Biophotonics & Molecular Imaging Research Center (BMIRC), National Yang-Ming University, 11221 Taipei, Taiwan
| | - Chung-Chun Liu
- Research Center for Applied Sciences, Academia Sinica, 11529 Taipei, Taiwan
| | - Huei-Jyuan Pan
- Research Center for Applied Sciences, Academia Sinica, 11529 Taipei, Taiwan
| | - Wei-Yu Liao
- Department of Internal Medicine, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei 10002, Taiwan
| | - Ji-Yen Cheng
- Research Center for Applied Sciences, Academia Sinica, 11529 Taipei, Taiwan ; Institute of Biophotonics, National Yang-Ming University, 11221 Taipei, Taiwan ; Biophotonics & Molecular Imaging Research Center (BMIRC), National Yang-Ming University, 11221 Taipei, Taiwan
| | - Po-Ling Kuo
- Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei 10617, Taiwan ; Department of Electrical Engineering, National Taiwan University, Taipei 10617, Taiwan
| | - Chau-Hwang Lee
- Research Center for Applied Sciences, Academia Sinica, 11529 Taipei, Taiwan ; Institute of Biophotonics, National Yang-Ming University, 11221 Taipei, Taiwan ; Biophotonics & Molecular Imaging Research Center (BMIRC), National Yang-Ming University, 11221 Taipei, Taiwan
| |
Collapse
|