1
|
Huang Y, Pu X, Qian H, Chuang CJ, Dong S, Wu J, Xue J, Cheng W, Ding S, Li S. Optical fiber surface plasmon resonance sensor using electroless-plated gold film for thrombin detection. Anal Bioanal Chem 2024; 416:1469-1483. [PMID: 38236393 DOI: 10.1007/s00216-024-05150-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 12/27/2023] [Accepted: 01/11/2024] [Indexed: 01/19/2024]
Abstract
This paper describes the simple and label-free detection of thrombin using optical fiber surface plasmon resonance (SPR) sensors based on gold films prepared by the cost-effective method of electroless plating. The plating conditions for simultaneously obtaining gold film on cylindrical core and end surfaces of an optical fiber suitable for measurement were optimized. The fabricated sensor exhibited a linear refractive index sensitivity of 2150 nm/RIU and 7.136 (a.u.)/RIU in the refractive index of 1.3329-1.3605 interrogated by resonance wavelength and amplitude methods respectively and a single wavelength monitoring method was proposed to investigate the sensing performance of this sensor. Polyadenine diblock and thiolated thrombin aptamers were immobilized on gold nanoparticles and gold films respectively to implement a sandwich optical fiber assay for thrombin. The developed optical fiber SPR sensors were successfully used in the determination of thrombin down to 0.56 nM over a wide range from 2 to 100 nM and showed good selectivity for thrombin, which indicated their potential clinical applications for biomedical samples.
Collapse
Affiliation(s)
- Yu Huang
- Chongqing Key Laboratory of Multi-scale Manufacturing Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing, 400714, China.
- Chongqing School, University of Chinese Academy of Sciences, Chongqing, 400714, China.
| | - Xiaoyin Pu
- Chongqing Key Laboratory of Multi-scale Manufacturing Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing, 400714, China
- Chongqing School, University of Chinese Academy of Sciences, Chongqing, 400714, China
| | - Husun Qian
- Department of Laboratory Medicine, The Affiliated Hospital of Guizhou Medical University, Guiyang, 550004, Guizhou, China
| | - Chin-Jung Chuang
- Department of Opto-Electronic Engineering, National Dong Hwa University, Hualien, 97401, Taiwan, China
| | - Shanshan Dong
- Department of Clinical Laboratory, Medical Sciences Research Center, University-Town Hospital of Chongqing Medical University, Chongqing, 401331, China
| | - Jiangling Wu
- Department of Clinical Laboratory, Medical Sciences Research Center, University-Town Hospital of Chongqing Medical University, Chongqing, 401331, China.
| | - Jianjiang Xue
- Department of Clinical Laboratory, Medical Sciences Research Center, University-Town Hospital of Chongqing Medical University, Chongqing, 401331, China
| | - Wei Cheng
- The Center for Clinical Molecular Medical Detection, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Shijia Ding
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine, Chongqing Medical University, Chongqing, 400016, China
| | - Shengqiang Li
- Clinical Laboratory, First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, Tianjin, 300000, China.
- National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, Tianjin, 300000, China.
| |
Collapse
|
2
|
Lou C, Yang H, Hou Y, Huang H, Qiu J, Wang C, Sang Y, Liu H, Han L. Microfluidic Platforms for Real-Time In Situ Monitoring of Biomarkers for Cellular Processes. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2307051. [PMID: 37844125 DOI: 10.1002/adma.202307051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 09/05/2023] [Indexed: 10/18/2023]
Abstract
Cellular processes are mechanisms carried out at the cellular level that are aimed at guaranteeing the stability of the organism they comprise. The investigation of cellular processes is key to understanding cell fate, understanding pathogenic mechanisms, and developing new therapeutic technologies. Microfluidic platforms are thought to be the most powerful tools among all methodologies for investigating cellular processes because they can integrate almost all types of the existing intracellular and extracellular biomarker-sensing methods and observation approaches for cell behavior, combined with precisely controlled cell culture, manipulation, stimulation, and analysis. Most importantly, microfluidic platforms can realize real-time in situ detection of secreted proteins, exosomes, and other biomarkers produced during cell physiological processes, thereby providing the possibility to draw the whole picture for a cellular process. Owing to their advantages of high throughput, low sample consumption, and precise cell control, microfluidic platforms with real-time in situ monitoring characteristics are widely being used in cell analysis, disease diagnosis, pharmaceutical research, and biological production. This review focuses on the basic concepts, recent progress, and application prospects of microfluidic platforms for real-time in situ monitoring of biomarkers in cellular processes.
Collapse
Affiliation(s)
- Chengming Lou
- State Key Laboratory of Crystal Materials, Shandong University, Jinan, 250100, P. R. China
| | - Hongru Yang
- State Key Laboratory of Crystal Materials, Shandong University, Jinan, 250100, P. R. China
| | - Ying Hou
- Institute for Advanced Interdisciplinary Research (IAIR), University of Jinan, Jinan, 250022, P. R. China
| | - Haina Huang
- Institute for Advanced Interdisciplinary Research (IAIR), University of Jinan, Jinan, 250022, P. R. China
| | - Jichuan Qiu
- State Key Laboratory of Crystal Materials, Shandong University, Jinan, 250100, P. R. China
| | - Chunhua Wang
- Institute for Advanced Interdisciplinary Research (IAIR), University of Jinan, Jinan, 250022, P. R. China
| | - Yuanhua Sang
- State Key Laboratory of Crystal Materials, Shandong University, Jinan, 250100, P. R. China
| | - Hong Liu
- State Key Laboratory of Crystal Materials, Shandong University, Jinan, 250100, P. R. China
- Institute for Advanced Interdisciplinary Research (IAIR), University of Jinan, Jinan, 250022, P. R. China
| | - Lin Han
- Institute of Marine Science and Technology, Shandong University, Qingdao, Shandong, 266000, P. R. China
| |
Collapse
|
3
|
In vivo real-time monitoring of anti-factor Xa level using a microdialysis-coupled microfluidic device. TALANTA OPEN 2021. [DOI: 10.1016/j.talo.2021.100059] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
4
|
Wang R, Zhou Y, Ghanbari Ghalehjoughi N, Mawaldi Y, Wang X. Ion-Induced Phase Transfer of Cationic Dyes for Fluorescence-Based Electrolyte Sensing in Droplet Microfluidics. Anal Chem 2021; 93:13694-13702. [PMID: 34590485 DOI: 10.1021/acs.analchem.1c03394] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Fluorescence-based sensing in droplet microfluidics requires small sample volumes, allows for high-throughput assays, and does not suffer from photobleaching as each flowing sensor is only scanned one time. In this paper, we report a selective and sensitive fluorescence-based ion-sensing methodology in droplet microfluidics using a T-junction PDMS chip. The oil stream is doped with sensor ingredients including an ionophore, a cation exchanger, and a permanently cationic fluorophore as the optical reporter. Electrolyte cations from the aqueous sample are extracted into oil segments and displace the cationic dyes into aqueous droplets. Laser-induced fluorescence of the two immiscible phases is collected alternately, which is in clear contrast to most other ion-selective optode configurations such as nanoparticle suspensions that rely on mixed optical signals of two phases. The cation exchanger, tetrakis[3,5-bis(trifluoromethyl)phenyl]borate, is found to dramatically enhance the dye emission in the nonpolar sensing oil by preventing ion-pairing interactions and aggregations of the dye molecules, providing new insights into the mechanism of cationic dye-based ion sensors. The high dye brightness allows us to use low concentrations of sensing chemicals (e.g., 10 μM) in the oil and attain high sensitivity for detection of ions in an equal volume of sample. Using valinomycin as the ionophore and methylene blue as the dye, K+ is detected with a response time of ∼11 s, a logarithmic linear range of 10-5 to 10-2 M, a 20-fold total fluorescence response, >1000-fold selectivity against other electrolyte cations, and negligible cross-sensitivity toward the sample pH. The K+ concentration in untreated and undiluted whole blood and sweat samples is successfully determined by this microfluidic sensing method without optical interference from the droplet sample to the sensing oil. Detection of other ionic analytes can be achieved using the corresponding ionophores.
Collapse
Affiliation(s)
- Renjie Wang
- Department of Chemistry, Virginia Commonwealth University, Richmond, Virginia 23284, United States
| | - Yang Zhou
- School of Chemical Engineering and Technology, Key Laboratory of Advanced Materials of Tropical Island Resources of Ministry of Education, Hainan University, Haikou, Hainan 570228, China
| | | | - Yazan Mawaldi
- Department of Chemistry, Virginia Commonwealth University, Richmond, Virginia 23284, United States
| | - Xuewei Wang
- Department of Chemistry, Virginia Commonwealth University, Richmond, Virginia 23284, United States
| |
Collapse
|
5
|
Jigar Panchal H, Kent NJ, Knox AJS, Harris LF. Microfluidics in Haemostasis: A Review. Molecules 2020; 25:E833. [PMID: 32075008 PMCID: PMC7070452 DOI: 10.3390/molecules25040833] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 02/11/2020] [Accepted: 02/12/2020] [Indexed: 12/17/2022] Open
Abstract
Haemostatic disorders are both complex and costly in relation to both their treatment and subsequent management. As leading causes of mortality worldwide, there is an ever-increasing drive to improve the diagnosis and prevention of haemostatic disorders. The field of microfluidic and Lab on a Chip (LOC) technologies is rapidly advancing and the important role of miniaturised diagnostics is becoming more evident in the healthcare system, with particular importance in near patient testing (NPT) and point of care (POC) settings. Microfluidic technologies present innovative solutions to diagnostic and clinical challenges which have the knock-on effect of improving health care and quality of life. In this review, both advanced microfluidic devices (R&D) and commercially available devices for the diagnosis and monitoring of haemostasis-related disorders and antithrombotic therapies, respectively, are discussed. Innovative design specifications, fabrication techniques, and modes of detection in addition to the materials used in developing micro-channels are reviewed in the context of application to the field of haemostasis.
Collapse
Affiliation(s)
- Heta Jigar Panchal
- School of Biological and Health Sciences, Technological University Dublin (TU Dublin) - City Campus, Kevin Street, Dublin D08 NF82, Ireland; (H.J.P.); (A.J.S.K.)
| | - Nigel J Kent
- engCORE, Faculty of Engineering, Institute of Technology Carlow, Kilkenny Road, Carlow R93 V960, Ireland;
| | - Andrew J S Knox
- School of Biological and Health Sciences, Technological University Dublin (TU Dublin) - City Campus, Kevin Street, Dublin D08 NF82, Ireland; (H.J.P.); (A.J.S.K.)
| | - Leanne F Harris
- School of Biological and Health Sciences, Technological University Dublin (TU Dublin) - City Campus, Kevin Street, Dublin D08 NF82, Ireland; (H.J.P.); (A.J.S.K.)
| |
Collapse
|
6
|
Mohammadi Aria M, Erten A, Yalcin O. Technology Advancements in Blood Coagulation Measurements for Point-of-Care Diagnostic Testing. Front Bioeng Biotechnol 2019; 7:395. [PMID: 31921804 PMCID: PMC6917661 DOI: 10.3389/fbioe.2019.00395] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Accepted: 11/21/2019] [Indexed: 12/24/2022] Open
Abstract
In recent years, blood coagulation monitoring has become crucial to diagnosing causes of hemorrhages, developing anticoagulant drugs, assessing bleeding risk in extensive surgery procedures and dialysis, and investigating the efficacy of hemostatic therapies. In this regard, advanced technologies such as microfluidics, fluorescent microscopy, electrochemical sensing, photoacoustic detection, and micro/nano electromechanical systems (MEMS/NEMS) have been employed to develop highly accurate, robust, and cost-effective point of care (POC) devices. These devices measure electrochemical, optical, and mechanical parameters of clotting blood. Which can be correlated to light transmission/scattering, electrical impedance, and viscoelastic properties. In this regard, this paper discusses the working principles of blood coagulation monitoring, physical and sensing parameters in different technologies. In addition, we discussed the recent progress in developing nanomaterials for blood coagulation detection and treatments which opens up new area of controlling and monitoring of coagulation at the same time in the future. Moreover, commercial products, future trends/challenges in blood coagulation monitoring including novel anticoagulant therapies, multiplexed sensing platforms, and the application of artificial intelligence in diagnosis and monitoring have been included.
Collapse
Affiliation(s)
| | - Ahmet Erten
- Department of Electronics and Communication Engineering, Istanbul Technical University, Istanbul, Turkey
| | - Ozlem Yalcin
- Graduate School of Biomedical Sciences and Engineering, Koc University, Sariyer, Turkey
- Department of Physiology, Koc University School of Medicine, Koc University, Sariyer, Turkey
| |
Collapse
|
7
|
Li H, Han D, Pauletti GM, Steckl AJ. Engineering a simple lateral flow device for animal blood coagulation monitoring. BIOMICROFLUIDICS 2018; 12:014110. [PMID: 29430275 PMCID: PMC5780276 DOI: 10.1063/1.5017496] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Accepted: 01/10/2018] [Indexed: 05/04/2023]
Abstract
Increasing numbers of animals are diagnosed with thromboembolism, requiring anticoagulation treatment to prevent thrombotic events. Frequent and periodic coagulation monitoring is critical to ensure treatment effectiveness and patient safety by limiting blood coagulation ability within the desired therapeutic range. Point-of-care diagnostics is an ideal candidate for frequent coagulation monitoring due to rapid test results and no need for laboratory setting. This article reports the first utilization of no-reaction lateral flow assay (nrLFA) device for simple and low-cost animal blood coagulation monitoring in resource-limited setting. The nrLFA device consists of sample pad, analytical membrane and wicking pad, without conjugate pad, reagent printing or membrane drying. Citrated and heparinized animal blood were utilized to mimic different blood coagulation abilities in vitro by adding reversal agents CaCl2 and protamine sulfate. The travel distance of red blood cells (RBCs) on the nrLFA after a pre-determined test time serves as endpoint marker. Upon adding 500 mM CaCl2 solution to citrated bovine, canine, rabbit and equine blood, the average travel distance decreases from 10.9 to 9.4 mm, 8.8 to 5.7 mm, 12.6 to 9 mm, and 15.3 to 11.3 mm, respectively. For heparinized bovine and rabbit blood, the average distance decreases from 14.5 to 11.4 mm and from 9.8 to 7.2 mm, respectively, when adding 300 mg/l protamine sulfate solution. The effect of hematocrit on RBC travel distance in the nrLFA was also investigated. The nrLFA device will potentially improve treatment efficiency, patient safety, quality of life, and satisfaction for both animal patients and their owners.
Collapse
Affiliation(s)
- Hua Li
- Nanoelectronics Laboratory, Department of Electrical Engineering and Computing Systems, University of Cincinnati, Cincinnati, Ohio 45221, USA
| | - Daewoo Han
- Nanoelectronics Laboratory, Department of Electrical Engineering and Computing Systems, University of Cincinnati, Cincinnati, Ohio 45221, USA
| | - Giovanni M Pauletti
- Winkle College of Pharmacy, University of Cincinnati, Cincinnati, Ohio 45267, USA
| | - Andrew J Steckl
- Nanoelectronics Laboratory, Department of Electrical Engineering and Computing Systems, University of Cincinnati, Cincinnati, Ohio 45221, USA
| |
Collapse
|
8
|
Lehmann M, Wallbank AM, Dennis KA, Wufsus AR, Davis KM, Rana K, Neeves KB. On-chip recalcification of citrated whole blood using a microfluidic herringbone mixer. BIOMICROFLUIDICS 2015; 9:064106. [PMID: 26634014 PMCID: PMC4654733 DOI: 10.1063/1.4935863] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2015] [Accepted: 11/02/2015] [Indexed: 05/20/2023]
Abstract
In vitro assays of platelet function and coagulation are typically performed in the presence of an anticoagulant. The divalent cation chelator sodium citrate is among the most common because its effect on coagulation is reversible upon reintroduction of divalent cations. Adding divalent cations into citrated blood by batch mixing leads to platelet activation and initiation of coagulation after several minutes, thus limiting the time blood can be used before spontaneously clotting. In this work, we describe a herringbone microfluidic mixer to continuously introduce divalent cations into citrated blood. The mixing ratio, defined as the ratio of the volumetric flow rates of citrated blood and recalcification buffer, can be adjusted by changing the relative inlet pressures of these two solutions. This feature is useful in whole blood assays in order to account for differences in hematocrit, and thus viscosity. The recalcification process in the herringbone mixer does not activate platelets. The advantage of this continuous mixing approach is demonstrated in microfluidic vascular injury model in which platelets and fibrin accumulate on a collagen-tissue factor surface under flow. Continuous recalcification with the herringbone mixer allowed for flow assay times of up to 30 min, more than three times longer than the time achieved by batch recalcification. This continuous mixer allows for measurements of thrombus formation, remodeling, and fibrinolysis in vitro over time scales that are relevant to these physiological processes.
Collapse
Affiliation(s)
- Marcus Lehmann
- Chemical and Biological Engineering Department, Colorado School of Mines , Golden, Colorado 80401, USA
| | - Alison M Wallbank
- Chemical and Biological Engineering Department, Colorado School of Mines , Golden, Colorado 80401, USA
| | - Kimberly A Dennis
- Chemical and Biological Engineering Department, Colorado School of Mines , Golden, Colorado 80401, USA
| | - Adam R Wufsus
- Chemical and Biological Engineering Department, Colorado School of Mines , Golden, Colorado 80401, USA
| | - Kara M Davis
- Chemical and Biological Engineering Department, Colorado School of Mines , Golden, Colorado 80401, USA
| | - Kuldeepsinh Rana
- Chemical and Biological Engineering Department, Colorado School of Mines , Golden, Colorado 80401, USA
| | - Keith B Neeves
- Chemical and Biological Engineering Department, Colorado School of Mines , Golden, Colorado 80401, USA
| |
Collapse
|
9
|
Skommer J, Wlodkowic D. Successes and future outlook for microfluidics-based cardiovascular drug discovery. Expert Opin Drug Discov 2015; 10:231-44. [PMID: 25672221 DOI: 10.1517/17460441.2015.1001736] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
INTRODUCTION The greatest advantage of using microfluidics as a platform for the assessment of cardiovascular drug action is its ability to finely regulate fluid flow conditions, including flow rate, shear stress and pulsatile flow. At the same time, microfluidics provide means for modifying the vessel geometry (bifurcations, stenoses, complex networks), the type of surface of the vessel walls, and for patterning cells in 3D tissue-like architecture, including generation of lumen walls lined with cells and heart-on-a-chip structures for mimicking ventricular cardiomyocyte physiology. In addition, owing to the small volume of required specimens, microfluidics is ideally suited to clinical situations whereby monitoring of drug dosing or efficacy needs to be coupled with minimal phlebotomy-related drug loss. AREAS COVERED In this review, the authors highlight potential applications for the currently existing and emerging technologies and offer several suggestions on how to close the development cycle of microfluidic devices for cardiovascular drug discovery. EXPERT OPINION The ultimate goal in microfluidics research for drug discovery is to develop 'human-on-a-chip' systems, whereby several organ cultures, including the vasculature and the heart, can mimic complex interactions between the organs and body systems. This would provide in vivo-like pharmacokinetics and pharmacodynamics for drug ADMET assessment. At present, however, the great variety of available designs does not go hand in hand with their use by the pharmaceutical community.
Collapse
Affiliation(s)
- Joanna Skommer
- RMIT University, School of Applied Sciences , Melbourne, VIC , Australia
| | | |
Collapse
|
10
|
Yu J, Tao D, Ng EX, Drum CL, Liu AQ, Chen CH. Real-time measurement of thrombin generation using continuous droplet microfluidics. BIOMICROFLUIDICS 2014; 8:052108. [PMID: 25332735 PMCID: PMC4189542 DOI: 10.1063/1.4894747] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2014] [Revised: 09/09/2014] [Accepted: 08/23/2014] [Indexed: 05/10/2023]
Abstract
Thrombin, which has the leading role in the blood coagulation cascade, is an important biomarker in hemostasis and cardiovascular disease (CVD) development. In this study, a measurement system capable of continuously monitoring individual thrombin generation using droplet microfluidic technology is manipulated. The thrombin generation assay based on fluogenic substrate is performed within the droplets and the thrombin generation curve of plasma sample activated by tissue factor is measured in real-time to reflect the sample conditions dynamically. The injection of the inhibitor of thrombin generation is developed to assay the inhibited curve which relates to thrombin self-inhibition in biological systems. This microfluidic system is integrated with the microdialysis probe, which is useful to connect to the living animals for future in vivo real time thrombin measurements for rapid CVD diagnosis.
Collapse
Affiliation(s)
- Jiaqing Yu
- Department of Biomedical Engineering, National University of Singapore , Singapore 117575
| | - Ding Tao
- Yong Loo Lin School of Medicine, National University of Singapore , Singapore 119228
| | - Ee Xing Ng
- Department of Biomedical Engineering, National University of Singapore , Singapore 117575
| | - Chester L Drum
- Yong Loo Lin School of Medicine, National University of Singapore , Singapore 119228
| | - Ai Qun Liu
- Department of Electrical and Electronic Engineering, Nanyang Technological University , Singapore 639798
| | | |
Collapse
|
11
|
Chou CF, Wei PK, Chen YL. Preface to Special Topic: Selected Papers from the Advances in Microfluidics and Nanofluidics 2014 Conference in Honor of Professor Hsueh-Chia Chang's 60th Birthday. BIOMICROFLUIDICS 2014; 8:051901. [PMID: 25538799 PMCID: PMC4241881 DOI: 10.1063/1.4900715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2014] [Accepted: 10/19/2014] [Indexed: 06/04/2023]
Affiliation(s)
| | - Pei-Kuen Wei
- Research Center for Applied Sciences , Academia Sinica, Taipei 11529, Taiwan
| | - Yeng-Long Chen
- Institute of Physics , Academia Sinica, Taipei 11529, Taiwan
| |
Collapse
|