1
|
Chen Y, Chen PJ, Hu R, Zhu Y, Yu JH, Pham AV, Momeni O, Domier C, Dannenberg J, Li X, Yu G, Luhmann N. Frontier system-on-chip (SoC) technology for microwave diagnostics (invited). THE REVIEW OF SCIENTIFIC INSTRUMENTS 2024; 95:093516. [PMID: 39254431 DOI: 10.1063/5.0219545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2024] [Accepted: 08/19/2024] [Indexed: 09/11/2024]
Abstract
The next generation of fusion reactors, exemplified by projects such as the Demonstration Power Plant following the International Thermonuclear Experimental Reactor, faces the monumental challenge of proving the viability of generating electricity through thermonuclear fusion. This pursuit introduces heightened complexities in diagnostic methodologies, particularly in microwave-based diagnostics. The increased neutron fluence necessitates significant reductions in vessel penetrations and the elimination of internal diagnostics, posing substantial challenges. SoC technology offers a promising solution by enabling the miniaturization, modularization, integration, and enhancing the reliability of microwave systems. After seven years of research, our team successfully pioneered the V- and W-band system-on-chip approach, leading to the development of active transmitters and passive receiver modules applied in practical settings, notably within the DIII-D tokamak project. Arrays of these modules have supported microwave imaging diagnostics. New physics measurement results from the Electron Cyclotron Emission Imaging system on DIII-D provide compelling evidence of improved diagnostics following the adoption of SoC technology. Furthermore, we achieved a breakthrough in developing an F-band SoC, advancing higher frequency capabilities for fusion devices. These achievements represent a significant leap forward in fusion diagnostic technology, marking substantial progress toward establishing reliable and efficient plasma diagnostics for future fusion reactors.
Collapse
Affiliation(s)
- Ying Chen
- University of California, Davis, California 95616, USA
| | - Pin-Jung Chen
- University of California, Davis, California 95616, USA
| | - Robert Hu
- National Yang Ming Chiao Tung University, Hsinchu, Taiwan, 30010
| | - Yilun Zhu
- University of California, Davis, California 95616, USA
| | - Jo-Han Yu
- University of California, Davis, California 95616, USA
| | - A-V Pham
- University of California, Davis, California 95616, USA
| | - Omeed Momeni
- University of California, Davis, California 95616, USA
| | - Calvin Domier
- University of California, Davis, California 95616, USA
| | | | - Xiaoliang Li
- University of California, Davis, California 95616, USA
| | - Guanying Yu
- University of California, Davis, California 95616, USA
| | | |
Collapse
|
2
|
Li X, Chen R, Xu G, Domier C, Liu X, Zhang Y, Zhou T, Zhu Y, Yu G, Qiu S, Yu H, Luhmann NC. Development of ultra-short pulse reflectometry on the Experimental Advanced Superconducting Tokamak (EAST). THE REVIEW OF SCIENTIFIC INSTRUMENTS 2024; 95:073519. [PMID: 39016701 DOI: 10.1063/5.0215730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2024] [Accepted: 07/01/2024] [Indexed: 07/18/2024]
Abstract
Microwave reflectometry is an invaluable diagnostic tool for measuring electron density profiles in large fusion devices. Density fluctuations near the plasma cutoff layer, particularly those that are time-varying on the timescale of the reflectometry measurement, can result in distortions in phase and/or amplitude of the reflected waveform, which present challenges to the accuracy of the reconstructed profile. The ultra-short pulse reflectometry (USPR) technique eliminates the time-varying issue in that reflectometry data are collected on a nanosecond timescale, essentially freezing the fluctuations in place. An X-mode dedicated 32-channel USPR system has been developed and installed on the EAST, covering the operation frequency range from 52 to 92 GHz. This system enables high-resolution density profile measurements in the plasma pedestal and scrape-off layer, with resolutions reaching 5 mm and 1 μs, respectively. Laboratory testing of the system performance has been conducted, demonstrating the potential of the USPR technique to provide accurate and high-temporal-resolution density profiles in challenging plasma environments.
Collapse
Affiliation(s)
- Xiaoliang Li
- Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, People's Republic of China
- University of California Davis, Davis, California 95616, USA
| | - Ran Chen
- Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, People's Republic of China
| | - Guosheng Xu
- Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, People's Republic of China
| | - Calvin Domier
- University of California Davis, Davis, California 95616, USA
| | - Xianzi Liu
- University of California Davis, Davis, California 95616, USA
| | - Yiwei Zhang
- Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, People's Republic of China
| | - Tianfu Zhou
- Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, People's Republic of China
| | - Yilun Zhu
- University of California Davis, Davis, California 95616, USA
| | - Guanying Yu
- University of California Davis, Davis, California 95616, USA
| | - Shasha Qiu
- University of California Davis, Davis, California 95616, USA
| | - Hai Yu
- University of California Davis, Davis, California 95616, USA
| | | |
Collapse
|
3
|
Jiang M, Zhu Y, Yu X, Shi Z, Luhmann N, Yang Z, Deng W, Yang Z, Zhou Y, Tong R. Optical design and synthetic analysis of the electron cyclotron emission imaging diagnostic of HL-2M tokamak. FUSION ENGINEERING AND DESIGN 2023. [DOI: 10.1016/j.fusengdes.2023.113570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
|
4
|
Zhu Y, Chen Y, Yu JH, Domier C, Yu G, Liu X, Kramer G, Ren Y, Diallo A, Luhmann NC, Li X. System-on-chip approach microwave imaging reflectometer on DIII-D tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:113509. [PMID: 36461457 DOI: 10.1063/5.0099170] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2022] [Accepted: 09/08/2022] [Indexed: 06/17/2023]
Abstract
System-on-chip millimeter wave integrated circuit technology is used on the two-dimensional millimeter-wave imaging reflectometer (MIR) upgrade for density fluctuation imaging on the DIII-D tokamak fusion plasma. Customized CMOS chips have been successfully developed for the transmitter module and receiver module array, covering the 55-75 GHz working band. The transmitter module has the capability of simultaneously launching eight tunable probe frequencies (>0 dBm output power each). The receiver enclosure contains 12 receiver modules in two vertical lines. The quasi-optical local oscillator coupling of previous MIR systems has been replaced with an internal active frequency multiplier chain for improved local oscillator power delivery and flexible installation in a narrow space together with improved shielding against electromagnetic interference. The 55-75 GHz low noise amplifier, used between the receiver antenna and the first-stage mixer, significantly improves module sensitivity and suppresses electronics noise. The receiver module has a 20 dB gain improvement compared with the mini-lens approach and better than -75 dBm sensitivity, and its electronics noise temperature has been reduced from 55 000 K down to 11 200 K. The V-band MIR system is developed for co-located multi-field investigation of MHD-scale fluctuations in the pedestal region with W-band electron cyclotron emission imaging on DIII-D tokamak.
Collapse
Affiliation(s)
- Y Zhu
- Department of Electrical and Computer Engineering, University of California Davis, Davis, California 95616, USA
| | - Y Chen
- Department of Electrical and Computer Engineering, University of California Davis, Davis, California 95616, USA
| | - J-H Yu
- Department of Electrical and Computer Engineering, University of California Davis, Davis, California 95616, USA
| | - C Domier
- Department of Electrical and Computer Engineering, University of California Davis, Davis, California 95616, USA
| | - G Yu
- Department of Electrical and Computer Engineering, University of California Davis, Davis, California 95616, USA
| | - X Liu
- Department of Electrical and Computer Engineering, University of California Davis, Davis, California 95616, USA
| | - G Kramer
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - Y Ren
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - A Diallo
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - N C Luhmann
- Department of Electrical and Computer Engineering, University of California Davis, Davis, California 95616, USA
| | - X Li
- Department of Electrical and Computer Engineering, University of California Davis, Davis, California 95616, USA
| |
Collapse
|
5
|
Realization of automatic data cleaning and feedback conditioning for J-TEXT ECEI signals based on machine learning. FUSION ENGINEERING AND DESIGN 2022. [DOI: 10.1016/j.fusengdes.2022.113065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
6
|
W-Band Modular Antenna/Detector Array for the Electron Cyclotron Emission Imaging System in KSTAR. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12052431] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
A design of a modular antenna/detector array for the electron cyclotron emission (ECE) imaging system at the Korea Superconducting Tokamak Advanced Research (KSTAR) is proposed. The modular antenna/detector array is based on a unit antenna/detector module, which consists of an elliptical mini-lens, a dual-dipole antenna, an antenna balun, a low-noise amplifier, and a metal frame. The proposed modular antenna/detector array resolves the problem in the conventional antenna/detector array where one faulty channel requires the entire array to be removed for the service. With the proposed modular array, each channel module can be easily and independently removed and replaced without interference to the rest of the array, thus minimizing the interrupted service time for maintenance. Moreover, the unit channel modules can be efficiently updated under a variety of the tokamak operation conditions. The antenna/detector modules are optimized to have improved performance, and are tested in a W-band test setup, and consistently provide the gain increase by 10~20 dB as compared with the conventional antenna/detector array. A set of the proposed modular antenna/detector array is currently installed and tested in the KSTAR ECE imaging system, and will consistently produce the improved ECE imaging to monitor MHD instability activities under various plasma operation conditions.
Collapse
|
7
|
High level of integration of front-end imaging optics system for electron cyclotron emission imaging diagnostics on the DIII-D tokamak. FUSION ENGINEERING AND DESIGN 2021. [DOI: 10.1016/j.fusengdes.2021.112915] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
8
|
Chen Y, Zhu Y, Yu JH, Ye Y, Yu G, Liu X, Domier C, Luhmann NC. Design of microwave broadband CMOS transmitter and receiver circuits for MIR and ECEI plasma diagnostics. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:043529. [PMID: 34243474 DOI: 10.1063/5.0040568] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 03/26/2021] [Indexed: 06/13/2023]
Abstract
To efficiently determine the plasma electron density fluctuations using the MIR diagnostic technique, a 55-75 GHz 65 nm-CMOS transmitter has been developed where four separate intermediate frequency (IF) signals are up-converted, amplified, and then combined to generate an 8-tone RF output; a broadband 90 nm-CMOS receiver has also been constructed, which consists of an RF-low noise amplifier (LNA), mixer, and IF amplifier. The circuits and their corresponding modules will soon be deployed on the DIII-D and NSTX-U fusion devices. A 110-140 GHz 65 nm-CMOS receiver has also been designed, which is suitable for measuring the deep-core temperature fluctuations in the DIII-D tokamak using the electron cyclotron emission imaging diagnostic system. In addition to the RF-LNA/balun, mixer, and IF amplifier, an LO balun/tripler and driving amplifier are now included in this highly integrated circuit chip. By adopting the microwave and millimeter-wave system-on-chip concept in the front-end system design, this paper demonstrates that compact transmitter and receiver modules can be easily built, which, in turn, facilitates array implementation and maintenance.
Collapse
Affiliation(s)
- Ying Chen
- University of California, Davis, Davis, California 95616, USA
| | - Yilun Zhu
- University of California, Davis, Davis, California 95616, USA
| | - Jo-Han Yu
- University of California, Davis, Davis, California 95616, USA
| | - Yu Ye
- University of California, Davis, Davis, California 95616, USA
| | - Guanying Yu
- University of California, Davis, Davis, California 95616, USA
| | - Xianzi Liu
- University of California, Davis, Davis, California 95616, USA
| | - Calvin Domier
- University of California, Davis, Davis, California 95616, USA
| | | |
Collapse
|
9
|
Zhu Y, Yu JH, Yu G, Ye Y, Tobias B, Diallo A, Kramer G, Ren Y, Domier CW, Li X, Luo C, Chen M, Chen Y, Luhmann NC. W-band system-on-chip electron cyclotron emission imaging system on DIII-D. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:093504. [PMID: 33003819 DOI: 10.1063/5.0018082] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 08/20/2020] [Indexed: 06/11/2023]
Abstract
Monolithic, millimeter-wave "system-on-chip" (SoC) technology has been employed in heterodyne receiver integrated circuit radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature profile and fluctuation evolution diagnostics. A prototype module operating in the E-band (72 GHz-80 GHz) was first employed in a 2 × 10 element array that demonstrated significant improvements over the previous quasi-optical Schottky diode mixer arrays during the 2018 operational campaign of the DIII-D tokamak. For compatibility with International Thermonuclear Experimental Reactor relevant scenarios on DIII-D, the SoC ECEI system was upgraded with 20 horn-waveguide receiver modules. Each individual module contains a University of California Davis designed W-band (75 GHz-110 GHz) receiver die that integrates a broadband low noise amplifier, a double balanced down-converting mixer, and a ×4 multiplier on the local oscillator (LO) chain. A ×2 multiplier and two IF amplifiers are packaged and selected to further boost the signal strength and downconvert the signal frequency. The upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature compared with the previous Schottky diode radio frequency mixer input systems; an internal 8 times multiplier chain is used to bring down the LO frequency below 12 GHz, thereby obviating the need for a large aperture for quasi-optical LO coupling and replacing it with coaxial connectors. Horn-waveguide shielding housing avoids out-of-band noise interference on each individual module. The upgraded ECEI system plays an important role for absolute electron temperature evolution and fluctuation measurements for edge and core region transport physics studies.
Collapse
Affiliation(s)
- Y Zhu
- University of California Davis, Davis, California 95616, USA
| | - J-H Yu
- University of California Davis, Davis, California 95616, USA
| | - G Yu
- University of California Davis, Davis, California 95616, USA
| | - Y Ye
- University of California Davis, Davis, California 95616, USA
| | - B Tobias
- Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA
| | - A Diallo
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - G Kramer
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - Y Ren
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - C W Domier
- University of California Davis, Davis, California 95616, USA
| | - X Li
- University of Science and Technology of China, Hefei, Anhui 230000, China
| | - C Luo
- University of California Davis, Davis, California 95616, USA
| | - M Chen
- University of California Davis, Davis, California 95616, USA
| | - Y Chen
- University of California Davis, Davis, California 95616, USA
| | - N C Luhmann
- University of California Davis, Davis, California 95616, USA
| |
Collapse
|
10
|
Zheng W, Wang Y, Zhang M, Wu F, Yang Z. A full stack data acquisition, archive and access solution for J-TEXT based on web technologies. FUSION ENGINEERING AND DESIGN 2020. [DOI: 10.1016/j.fusengdes.2019.111450] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
11
|
Quasi-optical electron cyclotron emission imaging diagnostic advancements on the J-TEXT tokamak. FUSION ENGINEERING AND DESIGN 2020. [DOI: 10.1016/j.fusengdes.2020.111636] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
12
|
Yang Z, Zhou J, Pan X, Cao J, Yu G, Domier C, Zhu Y, Chang F, Zhang Z, Gao Y, Luhmann N, Xie X. Development of intelligent control module for the J-TEXT electron cyclotron emission imaging system. FUSION ENGINEERING AND DESIGN 2020. [DOI: 10.1016/j.fusengdes.2020.111494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
13
|
Zhu Y, Ye Y, Yu JH, Tobias B, Pham AV, Wang Y, Luo C, Domier CW, Kramer G, Ren Y, Diallo A, Nazikian R, Chen M, Yu G, Luhmann NC. Liquid crystal polymer receiver modules for electron cyclotron emission imaging on the DIII-D tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:10H120. [PMID: 30399858 DOI: 10.1063/1.5035373] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2018] [Accepted: 05/30/2018] [Indexed: 06/08/2023]
Abstract
A new generation of millimeter-wave heterodyne imaging receiver arrays has been developed and demonstrated on the DIII-D electron cyclotron emission imaging (ECEI) system. Improved circuit integration, improved noise performance, and enhanced shielding from out-of-band emission are made possible by using advanced liquid crystal polymer (LCP) substrates and monolithic microwave integrated circuit (MMIC) receiver chips. This array exhibits ∼15 dB additional gain and >30× reduction in noise temperature compared to previous generation ECEI arrays. Each LCP horn-waveguide module houses a 3 × 3 mm GaAs MMIC receiver chip, which consists of a low noise millimeter-wave preamplifier, balanced mixer, and IF amplifier together with a local oscillator multiplier chain driven at ∼12 GHz. A proof-of-principle partial LCP instrument with 5 poloidal channels was installed on DIII-D in 2017, with a full proof-of-principle system (20 poloidal × 8 radial channels) installed and commissioned in early 2018. The enhanced shielding of the LCP modules is seen to greatly reduce the sensitivity of ECEI signals to out-of-band microwave noise which has plagued previous ECEI studies on DIII-D. The LCP ECEI system is expected to be a valuable diagnostic tool for pedestal region measurements, focusing particularly on electron temperature evolution during edge localized mode bursting.
Collapse
Affiliation(s)
- Y Zhu
- University of California Davis, Davis, California 95616, USA
| | - Y Ye
- University of California Davis, Davis, California 95616, USA
| | - J-H Yu
- University of California Davis, Davis, California 95616, USA
| | - B Tobias
- Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA
| | - A-V Pham
- University of California Davis, Davis, California 95616, USA
| | - Y Wang
- University of California Davis, Davis, California 95616, USA
| | - C Luo
- University of California Davis, Davis, California 95616, USA
| | - C W Domier
- University of California Davis, Davis, California 95616, USA
| | - G Kramer
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - Y Ren
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - A Diallo
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - R Nazikian
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - M Chen
- University of California Davis, Davis, California 95616, USA
| | - G Yu
- University of California Davis, Davis, California 95616, USA
| | - N C Luhmann
- University of California Davis, Davis, California 95616, USA
| |
Collapse
|