1
|
Chen Y, Chen PJ, Hu R, Zhu Y, Yu JH, Pham AV, Momeni O, Domier C, Dannenberg J, Li X, Yu G, Luhmann N. Frontier system-on-chip (SoC) technology for microwave diagnostics (invited). THE REVIEW OF SCIENTIFIC INSTRUMENTS 2024; 95:093516. [PMID: 39254431 DOI: 10.1063/5.0219545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2024] [Accepted: 08/19/2024] [Indexed: 09/11/2024]
Abstract
The next generation of fusion reactors, exemplified by projects such as the Demonstration Power Plant following the International Thermonuclear Experimental Reactor, faces the monumental challenge of proving the viability of generating electricity through thermonuclear fusion. This pursuit introduces heightened complexities in diagnostic methodologies, particularly in microwave-based diagnostics. The increased neutron fluence necessitates significant reductions in vessel penetrations and the elimination of internal diagnostics, posing substantial challenges. SoC technology offers a promising solution by enabling the miniaturization, modularization, integration, and enhancing the reliability of microwave systems. After seven years of research, our team successfully pioneered the V- and W-band system-on-chip approach, leading to the development of active transmitters and passive receiver modules applied in practical settings, notably within the DIII-D tokamak project. Arrays of these modules have supported microwave imaging diagnostics. New physics measurement results from the Electron Cyclotron Emission Imaging system on DIII-D provide compelling evidence of improved diagnostics following the adoption of SoC technology. Furthermore, we achieved a breakthrough in developing an F-band SoC, advancing higher frequency capabilities for fusion devices. These achievements represent a significant leap forward in fusion diagnostic technology, marking substantial progress toward establishing reliable and efficient plasma diagnostics for future fusion reactors.
Collapse
Affiliation(s)
- Ying Chen
- University of California, Davis, California 95616, USA
| | - Pin-Jung Chen
- University of California, Davis, California 95616, USA
| | - Robert Hu
- National Yang Ming Chiao Tung University, Hsinchu, Taiwan, 30010
| | - Yilun Zhu
- University of California, Davis, California 95616, USA
| | - Jo-Han Yu
- University of California, Davis, California 95616, USA
| | - A-V Pham
- University of California, Davis, California 95616, USA
| | - Omeed Momeni
- University of California, Davis, California 95616, USA
| | - Calvin Domier
- University of California, Davis, California 95616, USA
| | | | - Xiaoliang Li
- University of California, Davis, California 95616, USA
| | - Guanying Yu
- University of California, Davis, California 95616, USA
| | | |
Collapse
|
2
|
Yu G, Zhu Y, Kramer G, Austin M, Denk S, Yoo MG, Li X, Zhao B, Xie R, Li Z, Chen Y, Liu X, Qiu S, Luhmann NC. Modeling the electron cyclotron emission radiation signature from suprathermal electrons in a tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2024; 95:073505. [PMID: 38958514 DOI: 10.1063/5.0217728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Accepted: 06/19/2024] [Indexed: 07/04/2024]
Abstract
An Electron Cyclotron Emission (ECE) modeling code has been developed to model ECE radiation with an arbitrary electron momentum distribution, a small oblique angle, both ordinary (O-mode) and extraordinary polarizations (X-mode), and multiple cyclotron frequency harmonics. The emission and absorption coefficients are calculated using the Poynting theorem from the cold plasma dispersion and the electron-microwave interaction from the full anti-Hermitian tensor. The modeling shows several ECE radiation signatures that can be used to diagnose the population of suprathermal electrons in a tokamak. First, in an n = 2 X-mode (X2) optically thick plasma and oblique ECE view, the modeling shows that only suprathermal electrons, which reside in a finite region of the velocity and space domains, can effectively generate cyclotron emissions to the ECE receiver. The code also finds that the O1 mode is sensitive to suprathermal electrons of both a high v⊥ and v‖, while the X2 mode is dominantly sensitive to suprathermal electrons of a high v⊥. The modeling shows that an oblique ECE system with both X/O polarization and a broad frequency coverage can be used to effectively yield information of the suprathermal electron population in a tokamak.
Collapse
Affiliation(s)
- Guanying Yu
- University of California, Davis, California 95616, USA
| | - Yilun Zhu
- University of California, Davis, California 95616, USA
| | - Gerrit Kramer
- Princeton Plasma Physics Laboratory, Princeton, New York 08543, USA
| | - Max Austin
- The University of Texas at Austin, Austin, Texas 78712, USA
| | - Severin Denk
- General Atomics, San Diego, California 92121, USA
| | - Min-Gu Yoo
- General Atomics, San Diego, California 92121, USA
| | - Xiaoliang Li
- University of California, Davis, California 95616, USA
| | - Bingzhe Zhao
- University of Tennessee Knoxville, Knoxville, Tennessee 37996, USA
| | - Ruifeng Xie
- University of Wisconsin Madison, Madison, Wisconsin 53709, USA
| | - Zeyu Li
- University of Wisconsin Madison, Madison, Wisconsin 53709, USA
| | - Ying Chen
- University of California, Davis, California 95616, USA
| | - Xianzi Liu
- University of California, Davis, California 95616, USA
| | - Shasha Qiu
- University of California, Davis, California 95616, USA
| | - N C Luhmann
- University of California, Davis, California 95616, USA
| |
Collapse
|
3
|
Qiu S, Himes L, Domier C, Tang X, Liu X, Hu F, Yu G, Li X, Zhu Y, Luhmann N, Xie J, Wu Z. Design of a 140 GHz waveguide notch filter for millimeter-wave receiver module protection in fusion plasma diagnostics. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2024; 95:023503. [PMID: 38350476 DOI: 10.1063/5.0176796] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2023] [Accepted: 01/17/2024] [Indexed: 02/15/2024]
Abstract
A carefully designed waveguide-based millimeter-wave notch filter, operating at 140 GHz, safeguards plasma diagnostic instruments from gyrotron leakage. Utilizing cylindrical cavity resonators with aperture coupling, the filter efficiently resonates 140 GHz wave-power into the TE11p mode, optimizing various geometrical parameters for practical fabrication and high-yield production. Thorough thermal analysis ensures its ability to handle power. The filter achieves outstanding performance with over 90 dB rejection at 140 GHz while providing low insertion loss over the passband (110-138 GHz), which is ideally suited for system-on-chip approach F-band diagnostic system applications.
Collapse
Affiliation(s)
- Shasha Qiu
- University of California Davis, Davis, California 95616, USA
| | - Logan Himes
- University of California Davis, Davis, California 95616, USA
| | - Calvin Domier
- University of California Davis, Davis, California 95616, USA
| | - Xiaopin Tang
- University of California Davis, Davis, California 95616, USA
| | - Xianzi Liu
- University of California Davis, Davis, California 95616, USA
| | - Fengqi Hu
- University of California Davis, Davis, California 95616, USA
| | - Guanying Yu
- University of California Davis, Davis, California 95616, USA
| | - Xiaoliang Li
- University of California Davis, Davis, California 95616, USA
| | - Yilun Zhu
- University of California Davis, Davis, California 95616, USA
| | - Neville Luhmann
- University of California Davis, Davis, California 95616, USA
| | - Jinlin Xie
- University of Science and Technology of China, Hefei, Anhui 230026, China
| | - Zhengwei Wu
- University of Science and Technology of China, Hefei, Anhui 230026, China
| |
Collapse
|
4
|
Zhu Y, Chen Y, Yu JH, Domier C, Yu G, Liu X, Kramer G, Ren Y, Diallo A, Luhmann NC, Li X. System-on-chip approach microwave imaging reflectometer on DIII-D tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:113509. [PMID: 36461457 DOI: 10.1063/5.0099170] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2022] [Accepted: 09/08/2022] [Indexed: 06/17/2023]
Abstract
System-on-chip millimeter wave integrated circuit technology is used on the two-dimensional millimeter-wave imaging reflectometer (MIR) upgrade for density fluctuation imaging on the DIII-D tokamak fusion plasma. Customized CMOS chips have been successfully developed for the transmitter module and receiver module array, covering the 55-75 GHz working band. The transmitter module has the capability of simultaneously launching eight tunable probe frequencies (>0 dBm output power each). The receiver enclosure contains 12 receiver modules in two vertical lines. The quasi-optical local oscillator coupling of previous MIR systems has been replaced with an internal active frequency multiplier chain for improved local oscillator power delivery and flexible installation in a narrow space together with improved shielding against electromagnetic interference. The 55-75 GHz low noise amplifier, used between the receiver antenna and the first-stage mixer, significantly improves module sensitivity and suppresses electronics noise. The receiver module has a 20 dB gain improvement compared with the mini-lens approach and better than -75 dBm sensitivity, and its electronics noise temperature has been reduced from 55 000 K down to 11 200 K. The V-band MIR system is developed for co-located multi-field investigation of MHD-scale fluctuations in the pedestal region with W-band electron cyclotron emission imaging on DIII-D tokamak.
Collapse
Affiliation(s)
- Y Zhu
- Department of Electrical and Computer Engineering, University of California Davis, Davis, California 95616, USA
| | - Y Chen
- Department of Electrical and Computer Engineering, University of California Davis, Davis, California 95616, USA
| | - J-H Yu
- Department of Electrical and Computer Engineering, University of California Davis, Davis, California 95616, USA
| | - C Domier
- Department of Electrical and Computer Engineering, University of California Davis, Davis, California 95616, USA
| | - G Yu
- Department of Electrical and Computer Engineering, University of California Davis, Davis, California 95616, USA
| | - X Liu
- Department of Electrical and Computer Engineering, University of California Davis, Davis, California 95616, USA
| | - G Kramer
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - Y Ren
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - A Diallo
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - N C Luhmann
- Department of Electrical and Computer Engineering, University of California Davis, Davis, California 95616, USA
| | - X Li
- Department of Electrical and Computer Engineering, University of California Davis, Davis, California 95616, USA
| |
Collapse
|
5
|
Yu G, Zhu Y, Austin M, Chen Y, Cao J, Diallo A, Kramer G, Li Z, Li X, Liu X, Nazikian R, Zheng Y, Luhmann NC. Diagnosing the pedestal magnetic field and magnetohydrodynamics radial structure with pedestal-scrape of layer electron cyclotron emission radiation inversion in H-mode plasma (invited). THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:103528. [PMID: 36319341 DOI: 10.1063/5.0099348] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Accepted: 09/09/2022] [Indexed: 06/16/2023]
Abstract
Forward modeling is used to interpret inversion patterns of the pedestal-Scrape of Layer (SOL) Electron Cyclotron Emission (ECE) in DIII-D H-mode experiments. The modeling not only significantly improves the ECE data interpretation quality but also leads to the potential measurements of (1) the magnetic field strength |B| at the separatrix, (2) the pedestal |B| evolution during an inter-Edge Localized Mode (ELM) period, and (3) the pedestal Magnetohydrodynamics (MHD) radial structure. The ECE shine-through effect leads to three types of pedestal-SOL radiation inversions that are discussed in this paper. The first type of inversion is the non-monotonic Te,rad profile with respect to the major radius. Using the ECE frequency at the minimum Te,rad, the inversion can be applied to measure the magnetic field |B| at the separatrix and calibrate the mapping of the ECE channels with respect to the separatrix. The second type of inversion refers to the opposite phase between the radiation fluctuations δTe,rad at the pedestal and SOL. This δTe,rad phase inversion is sensitive to density and temperature fluctuations at the pedestal foot and, thus, can be used to qualitatively measure the MHD radial structure. The third type of inversion appears when the pedestal and SOL Te,rad evolve in an opposite trend, which can be used to infer the pedestal |B| field change during an inter-ELM period. The bandwidth effect on measuring δTe,rad due to pedestal MHD is also investigated in the radiation modeling.
Collapse
Affiliation(s)
- G Yu
- Department of Electrical and Computer Engineering, University of California, Davis, California 95616, USA
| | - Y Zhu
- Department of Electrical and Computer Engineering, University of California, Davis, California 95616, USA
| | - M Austin
- Institute for Fusion Studies, University of Texas, Austin, Texas 78712, USA
| | - Y Chen
- Department of Electrical and Computer Engineering, University of California, Davis, California 95616, USA
| | - J Cao
- Department of Electrical and Computer Engineering, University of California, Davis, California 95616, USA
| | - A Diallo
- Princeton Plasma Physics Lab, Princeton, New Jersey 08540, USA
| | - G Kramer
- Princeton Plasma Physics Lab, Princeton, New Jersey 08540, USA
| | - Z Li
- Oak Ridge Associated Universities, Oak Ridge, Tennessee 37831, USA
| | - X Li
- Department of Electrical and Computer Engineering, University of California, Davis, California 95616, USA
| | - X Liu
- Department of Electrical and Computer Engineering, University of California, Davis, California 95616, USA
| | - R Nazikian
- General Atomic, San Diego, California 92121, USA
| | - Y Zheng
- Department of Electrical and Computer Engineering, University of California, Davis, California 95616, USA
| | - N C Luhmann
- Department of Electrical and Computer Engineering, University of California, Davis, California 95616, USA
| |
Collapse
|
6
|
High level of integration of front-end imaging optics system for electron cyclotron emission imaging diagnostics on the DIII-D tokamak. FUSION ENGINEERING AND DESIGN 2021. [DOI: 10.1016/j.fusengdes.2021.112915] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
7
|
Zhu Y, Yu JH, Yu G, Ye Y, Chen Y, Tobias B, Diallo A, Kramer G, Ren Y, Tang W, Dong G, Churchill R, Domier CW, Li X, Luo C, Chen M, Luhmann NC. System-on-chip upgrade of millimeter-wave imaging diagnostics for fusion plasma. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:053522. [PMID: 34243257 DOI: 10.1063/5.0040449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2020] [Accepted: 04/23/2021] [Indexed: 06/13/2023]
Abstract
Monolithic, millimeter wave "system-on-chip" technology has been employed in chip heterodyne radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature and fluctuation diagnostics. The system employs 20 horn-waveguide receiver modules each with customized W-band (75-110 GHz) monolithic microwave integrated circuit chips comprising a W-band low noise amplifier, a balanced mixer, a ×2 local oscillator (LO) frequency doubler, and two intermediate frequency amplifier stages in each module. Compared to previous quasi-optical ECEI arrays with Schottky mixer diodes mounted on planar antennas, the upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature; an internal eight times multiplier chain is used to provide LO coupling, thereby eliminating the need for quasi-optical coupling. The horn-waveguide shielding housing avoids out-of-band noise interference on each module. The upgraded ECEI system plays an important role for absolute electron temperature and fluctuation measurements for edge and core region transport physics studies. An F-band receiver chip (up to 140 GHz) is under development for additional fusion facilities with a higher toroidal magnetic field. Visualization diagnostics provide multi-scale and multi-dimensional data in plasma profile evolution. A significant aspect of imaging measurement is focusing on artificial intelligence for science applications.
Collapse
Affiliation(s)
- Y Zhu
- University of California Davis, Davis, California 95616, USA
| | - J-H Yu
- University of California Davis, Davis, California 95616, USA
| | - G Yu
- University of California Davis, Davis, California 95616, USA
| | - Y Ye
- University of California Davis, Davis, California 95616, USA
| | - Y Chen
- University of California Davis, Davis, California 95616, USA
| | - B Tobias
- Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA
| | - A Diallo
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - G Kramer
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - Y Ren
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - W Tang
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - G Dong
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - R Churchill
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - C W Domier
- University of California Davis, Davis, California 95616, USA
| | - X Li
- University of Science and Technology of China, Hefei, Anhui 230000, China
| | - C Luo
- University of California Davis, Davis, California 95616, USA
| | - M Chen
- University of California Davis, Davis, California 95616, USA
| | - N C Luhmann
- University of California Davis, Davis, California 95616, USA
| |
Collapse
|
8
|
Chen Y, Zhu Y, Yu JH, Ye Y, Yu G, Liu X, Domier C, Luhmann NC. Design of microwave broadband CMOS transmitter and receiver circuits for MIR and ECEI plasma diagnostics. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:043529. [PMID: 34243474 DOI: 10.1063/5.0040568] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 03/26/2021] [Indexed: 06/13/2023]
Abstract
To efficiently determine the plasma electron density fluctuations using the MIR diagnostic technique, a 55-75 GHz 65 nm-CMOS transmitter has been developed where four separate intermediate frequency (IF) signals are up-converted, amplified, and then combined to generate an 8-tone RF output; a broadband 90 nm-CMOS receiver has also been constructed, which consists of an RF-low noise amplifier (LNA), mixer, and IF amplifier. The circuits and their corresponding modules will soon be deployed on the DIII-D and NSTX-U fusion devices. A 110-140 GHz 65 nm-CMOS receiver has also been designed, which is suitable for measuring the deep-core temperature fluctuations in the DIII-D tokamak using the electron cyclotron emission imaging diagnostic system. In addition to the RF-LNA/balun, mixer, and IF amplifier, an LO balun/tripler and driving amplifier are now included in this highly integrated circuit chip. By adopting the microwave and millimeter-wave system-on-chip concept in the front-end system design, this paper demonstrates that compact transmitter and receiver modules can be easily built, which, in turn, facilitates array implementation and maintenance.
Collapse
Affiliation(s)
- Ying Chen
- University of California, Davis, Davis, California 95616, USA
| | - Yilun Zhu
- University of California, Davis, Davis, California 95616, USA
| | - Jo-Han Yu
- University of California, Davis, Davis, California 95616, USA
| | - Yu Ye
- University of California, Davis, Davis, California 95616, USA
| | - Guanying Yu
- University of California, Davis, Davis, California 95616, USA
| | - Xianzi Liu
- University of California, Davis, Davis, California 95616, USA
| | - Calvin Domier
- University of California, Davis, Davis, California 95616, USA
| | | |
Collapse
|
9
|
Zhu Y, Yu JH, Yu G, Ye Y, Tobias B, Diallo A, Kramer G, Ren Y, Domier CW, Li X, Luo C, Chen M, Chen Y, Luhmann NC. W-band system-on-chip electron cyclotron emission imaging system on DIII-D. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:093504. [PMID: 33003819 DOI: 10.1063/5.0018082] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 08/20/2020] [Indexed: 06/11/2023]
Abstract
Monolithic, millimeter-wave "system-on-chip" (SoC) technology has been employed in heterodyne receiver integrated circuit radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature profile and fluctuation evolution diagnostics. A prototype module operating in the E-band (72 GHz-80 GHz) was first employed in a 2 × 10 element array that demonstrated significant improvements over the previous quasi-optical Schottky diode mixer arrays during the 2018 operational campaign of the DIII-D tokamak. For compatibility with International Thermonuclear Experimental Reactor relevant scenarios on DIII-D, the SoC ECEI system was upgraded with 20 horn-waveguide receiver modules. Each individual module contains a University of California Davis designed W-band (75 GHz-110 GHz) receiver die that integrates a broadband low noise amplifier, a double balanced down-converting mixer, and a ×4 multiplier on the local oscillator (LO) chain. A ×2 multiplier and two IF amplifiers are packaged and selected to further boost the signal strength and downconvert the signal frequency. The upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature compared with the previous Schottky diode radio frequency mixer input systems; an internal 8 times multiplier chain is used to bring down the LO frequency below 12 GHz, thereby obviating the need for a large aperture for quasi-optical LO coupling and replacing it with coaxial connectors. Horn-waveguide shielding housing avoids out-of-band noise interference on each individual module. The upgraded ECEI system plays an important role for absolute electron temperature evolution and fluctuation measurements for edge and core region transport physics studies.
Collapse
Affiliation(s)
- Y Zhu
- University of California Davis, Davis, California 95616, USA
| | - J-H Yu
- University of California Davis, Davis, California 95616, USA
| | - G Yu
- University of California Davis, Davis, California 95616, USA
| | - Y Ye
- University of California Davis, Davis, California 95616, USA
| | - B Tobias
- Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA
| | - A Diallo
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - G Kramer
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - Y Ren
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - C W Domier
- University of California Davis, Davis, California 95616, USA
| | - X Li
- University of Science and Technology of China, Hefei, Anhui 230000, China
| | - C Luo
- University of California Davis, Davis, California 95616, USA
| | - M Chen
- University of California Davis, Davis, California 95616, USA
| | - Y Chen
- University of California Davis, Davis, California 95616, USA
| | - N C Luhmann
- University of California Davis, Davis, California 95616, USA
| |
Collapse
|
10
|
Quasi-optical electron cyclotron emission imaging diagnostic advancements on the J-TEXT tokamak. FUSION ENGINEERING AND DESIGN 2020. [DOI: 10.1016/j.fusengdes.2020.111636] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
11
|
Yang Z, Zhou J, Pan X, Cao J, Yu G, Domier C, Zhu Y, Chang F, Zhang Z, Gao Y, Luhmann N, Xie X. Development of intelligent control module for the J-TEXT electron cyclotron emission imaging system. FUSION ENGINEERING AND DESIGN 2020. [DOI: 10.1016/j.fusengdes.2020.111494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|