1
|
Zheng Y, Zhang Z, Zhang Y, Pan Q, Yan X, Li X, Yang Z. Enhancing Ultrasound Power Transfer: Efficiency, Acoustics, and Future Directions. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024:e2407395. [PMID: 39044603 DOI: 10.1002/adma.202407395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2024] [Revised: 07/01/2024] [Indexed: 07/25/2024]
Abstract
Implantable medical devices (IMDs), like pacemakers regulating heart rhythm or deep brain stimulators treating neurological disorders, revolutionize healthcare. However, limited battery life necessitates frequent surgeries for replacements. Ultrasound power transfer (UPT) emerges as a promising solution for sustainable IMD operation. Current research prioritizes implantable materials, with less emphasis on sound field analysis and maximizing energy transfer during wireless power delivery. This review addresses this gap. A comprehensive analysis of UPT technology, examining cutting-edge system designs, particularly in power supply and efficiency is provided. The review critically examines existing efficiency models, summarizing the key parameters influencing energy transmission in UPT systems. For the first time, an energy flow diagram of a general UPT system is proposed to offer insights into the overall functioning. Additionally, the review explores the development stages of UPT technology, showcasing representative designs and applications. The remaining challenges, future directions, and exciting opportunities associated with UPT are discussed. By highlighting the importance of sustainable IMDs with advanced functions like biosensing and closed-loop drug delivery, as well as UPT's potential, this review aims to inspire further research and advancements in this promising field.
Collapse
Affiliation(s)
- Yi Zheng
- Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Hong Kong, SAR, 999077, China
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, SAR, 999077, China
| | - Zhuomin Zhang
- Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Hong Kong, SAR, 999077, China
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, SAR, 999077, China
| | - Yanhu Zhang
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, SAR, 999077, China
- School of Mechanical Engineering, Jiangsu University, Zhenjiang, 212013, China
| | - Qiqi Pan
- Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Hong Kong, SAR, 999077, China
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, SAR, 999077, China
| | - Xiaodong Yan
- Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Hong Kong, SAR, 999077, China
| | - Xuemu Li
- Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Hong Kong, SAR, 999077, China
| | - Zhengbao Yang
- Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Hong Kong, SAR, 999077, China
| |
Collapse
|
2
|
Kuang X, Rong Q, Belal S, Vu T, López AML, Wang N, Arıcan MO, Garciamendez-Mijares CE, Chen M, Yao J, Zhang YS. Self-enhancing sono-inks enable deep-penetration acoustic volumetric printing. Science 2023; 382:1148-1155. [PMID: 38060634 PMCID: PMC11034850 DOI: 10.1126/science.adi1563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Accepted: 10/13/2023] [Indexed: 04/24/2024]
Abstract
Volumetric printing, an emerging additive manufacturing technique, builds objects with enhanced printing speed and surface quality by forgoing the stepwise ink-renewal step. Existing volumetric printing techniques almost exclusively rely on light energy to trigger photopolymerization in transparent inks, limiting material choices and build sizes. We report a self-enhancing sonicated ink (or sono-ink) design and corresponding focused-ultrasound writing technique for deep-penetration acoustic volumetric printing (DAVP). We used experiments and acoustic modeling to study the frequency and scanning rate-dependent acoustic printing behaviors. DAVP achieves the key features of low acoustic streaming, rapid sonothermal polymerization, and large printing depth, enabling the printing of volumetric hydrogels and nanocomposites with various shapes regardless of their optical properties. DAVP also allows printing at centimeter depths through biological tissues, paving the way toward minimally invasive medicine.
Collapse
Affiliation(s)
- Xiao Kuang
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, Cambridge, MA 02139, USA
| | - Qiangzhou Rong
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
| | - Saud Belal
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
| | - Tri Vu
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
| | - Alice M. López López
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, Cambridge, MA 02139, USA
| | - Nanchao Wang
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
| | - Mehmet Onur Arıcan
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, Cambridge, MA 02139, USA
| | - Carlos Ezio Garciamendez-Mijares
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, Cambridge, MA 02139, USA
| | - Maomao Chen
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
| | - Junjie Yao
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
| | - Yu Shrike Zhang
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, Cambridge, MA 02139, USA
| |
Collapse
|
3
|
Sallam A, Shahab S. Nonlinear Acoustic Holography With Adaptive Sampling. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2023; 70:1516-1526. [PMID: 37703162 DOI: 10.1109/tuffc.2023.3315011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/15/2023]
Abstract
Accurate and efficient numerical simulation of highly nonlinear ultrasound propagation is essential for a wide range of therapeutic and physical ultrasound applications. However, due to large domain sizes and the generation of higher harmonics, such simulations are computationally challenging, particularly in 3-D problems with shock waves. Current numerical methods are based on computationally inefficient uniform meshes that resolve the highest harmonics across the entire spatial domain. To address this challenge, we present an adaptive numerical algorithm for computationally efficient nonlinear acoustic holography. At each propagation step, the algorithm monitors the harmonic content of the acoustic signal and adjusts its discretization parameters accordingly. This enables efficient local resolution of higher harmonics in areas of high nonlinearity while avoiding unnecessary resolution elsewhere. Furthermore, the algorithm actively adapts to the signal's nonlinearity level, eliminating the need for prior reference simulations or information about the spatial distribution of the harmonic content of the acoustic field. The proposed algorithm incorporates an upsampling process in the frequency domain to accommodate the generation of higher harmonics in forward propagation and a downsampling process when higher harmonics are decimated in backward propagation. The efficiency of the algorithm was evaluated for highly nonlinear 3-D problems, demonstrating a significant reduction in computational cost with a nearly 50-fold speedup over a uniform mesh implementation. Our findings enable a more rapid and efficient approach to modeling nonlinear high-intensity focused ultrasound (HIFU) wave propagation.
Collapse
|
4
|
Freychet O, Frassati F, Boisseau S, Brulais S, Despesse G. Multiple input single output configurations to improve performances and robustness of acoustic power transfer. ULTRASONICS 2021; 116:106524. [PMID: 34274744 DOI: 10.1016/j.ultras.2021.106524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 06/17/2021] [Accepted: 07/07/2021] [Indexed: 06/13/2023]
Abstract
Powering and communicating with sensors placed behind metal walls is required in various applications such as submarine hulls, pressurized tanks or pipes. Acoustic power transfer (APT) is an excellent option to supply these sensors without making through holes. However, the power transfer performances of APT systems can be strongly degraded by the destructive interferences of emitted waves, typically when the receiver diameter is smaller than the transmitter's one. In this paper, the use of multiple transmitters to focalize acoustic waves on a receiver is analyzed and the equations determining the optimal magnitudes and phases of the input voltages are presented. We experimentally validate that the efficiency and the transmitted power are strongly improved with the proposed technique. The transmitted power and the efficiency are multiplied by two for aligned transducers while the transmitted power is multiplied by up to 45 for misaligned transducers. It is hence demonstrated that using multiple emitters is particularly well suited for industrial applications where high power and high robustness are needed. Moreover, it paves the way toward the power supply of non-aligned distributed sensor nodes, which are of particular interest in structural health monitoring.
Collapse
Affiliation(s)
- O Freychet
- Univ. Grenoble Alpes, CEA, Leti, F-38000 Grenoble, France.
| | - F Frassati
- Univ. Grenoble Alpes, CEA, Leti, F-38000 Grenoble, France
| | - S Boisseau
- Univ. Grenoble Alpes, CEA, Leti, F-38000 Grenoble, France
| | - S Brulais
- Univ. Grenoble Alpes, CEA, Leti, F-38000 Grenoble, France
| | - G Despesse
- Univ. Grenoble Alpes, CEA, Leti, F-38000 Grenoble, France
| |
Collapse
|