1
|
He H, Wang X, Tan H, Xiang S, Xu Y. The culture of A549 cells and its secreted cytokine IL-6 monitoring on the designed multifunctional microfluidic chip. Talanta 2024; 285:127395. [PMID: 39706033 DOI: 10.1016/j.talanta.2024.127395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2024] [Revised: 12/09/2024] [Accepted: 12/14/2024] [Indexed: 12/23/2024]
Abstract
A multifunctional microfluidic chip integrated with perfusion cell culture and in situ SERS detection of cell secretion was designed and developed for the detection of IL-6 secretion from LPS-stimulation of A549 cells in this paper. Researching works were focused on A549 cell activity and secretion in the constructed LPS-stimulated A549 cells model. On the designed microchip, a bubble trap chamber was designed to remove the bubbles in the culture medium which could also be simultaneously preheated by a split hot plate. Then, a long-time perfusion culture process of 549 cells could be realized. Under the optimized conditions the A549 cells could be cultured and kept in good activity for more than 36 h. Subsequently, the model of interaction between LPS and A549 cells was established on the designed microchip. When LPS-stimulated A549 cells, the IL-6 which was one of the secretions formed in this process was detected quantitatively by SERS spectral technique. The silver-coated gold nano-stars were prepared and taken as a sensitive enhancing probe for the SERS detection of IL-6 secreted from LPS-stimulated A549 cells. The immunomagnetic beads, IL-6 antigen, and SERS probes were mixed and incubated in the microchip and form a sandwich structure which was captured by the permanent magnet in the detection zone for SERS detection. The reference material of IL-6 was used to establish the calibration curve, and the linear range and detection limit were 1-10000 pg/mL and 0.75 pg/mL, respectively. Then, the IL-6 secretion from LPS-stimulated A549 cells was detected hourly for 7 h by this established method. The process of LPS stimulation of A594 cells did not lead to a sustained increase in the SERS spectral signature of IL-6. Instead, IL6 secretion initially increased sharply, then decreased and eventually stabilized. It could be due to a potential mechanism that the cells self-regulated to mitigate the inflammatory effects in response to sustained stimulation. The proposed multifunctional microfluidic chip, characterized by high sensitivity and the ability to perform continuous hourly detection, exhibited significant application prospects in the study of external stimulation on cells.
Collapse
Affiliation(s)
- Hong He
- Key Disciplines Lab of Novel Micro-Nano Devices and System Technology, Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Shapingba, Chongqing, 400044, China; School of Optoelectronics Engineering, Chongqing University, Shapingba, Chongqing, 400044, China
| | - Xiaoli Wang
- Key Disciplines Lab of Novel Micro-Nano Devices and System Technology, Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Shapingba, Chongqing, 400044, China; School of Optoelectronics Engineering, Chongqing University, Shapingba, Chongqing, 400044, China
| | - Haolan Tan
- School of Chemistry and Chemical Engineering, Chongqing University, Shapingba, Chongqing, 401331, China
| | - Songtao Xiang
- Department of Clinical Laboratory Medicine, Southwest Hospital, Army Medical University, 30 Gaotanyan, Shapingba District, Chongqing, 400038, China
| | - Yi Xu
- Key Disciplines Lab of Novel Micro-Nano Devices and System Technology, Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Shapingba, Chongqing, 400044, China; School of Optoelectronics Engineering, Chongqing University, Shapingba, Chongqing, 400044, China.
| |
Collapse
|
2
|
Yahyazadeh Shourabi A, Kieffer R, de Jong D, Tam D, Aubin-Tam ME. Mechanical characterization of freestanding lipid bilayers with temperature-controlled phase. SOFT MATTER 2024; 20:8524-8537. [PMID: 39417217 DOI: 10.1039/d4sm00706a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2024]
Abstract
Coexistence of lipid domains in cell membranes is associated with vital biological processes. Here, we investigate two such membranes: a multi-component membrane composed of DOPC and DPPC lipids with gel and fluid separated domains, and a single component membrane composed of PMPC lipids forming ripples. We characterize their mechanical properties below their melting point, where ordered and disordered regions coexist, and above their melting point, where they are in fluid phase. To conduct these inquiries, we create lipid bilayers in a microfluidic chip interfaced with a heating system and optical tweezers. The chip features a bubble trap and enables high-throughput formation of planar bilayers. Optical tweezers experiments reveal interfacial hydrodynamics (fluid-slip) and elastic properties (membrane tension and bending rigidity) at various temperatures. For PMPC bilayers, we demonstrate a higher fluid slip at the interface in the fluid-phase compared to the ripple phase, while for the DOPC:DPPC mixture, similar fluid slip is measured below and above the transition point. Membrane tension for both compositions increases after thermal fluidization. Bending rigidity is also measured using the forces required to extend a lipid nanotube pushed out of the freestanding membranes. This novel temperature-controlled microfluidic platform opens numerous possibilities for thermomechanical studies on freestanding planar membranes.
Collapse
Affiliation(s)
- Arash Yahyazadeh Shourabi
- Department of Bionanoscience, Kavli institute of Nanoscience, Delft University of Technology, Van der Maasweg 9, 2629 HZ, Delft, The Netherlands.
| | - Roland Kieffer
- Department of Bionanoscience, Kavli institute of Nanoscience, Delft University of Technology, Van der Maasweg 9, 2629 HZ, Delft, The Netherlands.
| | - Djanick de Jong
- Department of Bionanoscience, Kavli institute of Nanoscience, Delft University of Technology, Van der Maasweg 9, 2629 HZ, Delft, The Netherlands.
| | - Daniel Tam
- Laboratory for Aero and Hydrodynamics, Faculty of Mechanical Engineering, Delft University of Technology, 2628 CD, Delft, The Netherlands.
| | - Marie-Eve Aubin-Tam
- Department of Bionanoscience, Kavli institute of Nanoscience, Delft University of Technology, Van der Maasweg 9, 2629 HZ, Delft, The Netherlands.
| |
Collapse
|
3
|
Zhang A, Tharwani K, Wang J, Seilo GK, Atie MA, Potkay JA. Roll-to-roll manufacturing of large surface area PDMS devices, and application to a microfluidic artificial lung. LAB ON A CHIP 2024; 24:4357-4370. [PMID: 39148312 PMCID: PMC11327552 DOI: 10.1039/d4lc00339j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2024] [Accepted: 07/16/2024] [Indexed: 08/17/2024]
Abstract
The ability to cost-effectively produce large surface area microfluidic devices would bring many small-scale technologies such as microfluidic artificial lungs (μALs) from the realm of research to clinical and commercial applications. However, efforts to scale up these devices, such as by stacking multiple flat μALs have been labor intensive and resulted in bulky devices. Here, we report an automated manufacturing system, and a series of cylindrical multi-layer lungs manufactured with the system and tested for fluidic fidelity and function. A roll-to-roll (R2R) system to engrave multiple-layer devices was assembled. Unlike typical applications of R2R, the rolling process is synchronized to achieve consistent radial positioning. This allows the fluidics in the final device to be accessed without being unwrapped. To demonstrate the capabilities of the R2R manufacturing system, this method was used to manufacture multi-layer μALs. Gas and blood are engraved in alternating layers and routed orthogonally to each other. The proximity of gas and blood separated by gas permeable PDMS permits CO2 and O2 exchange via diffusion. After manufacturing, they were evaluated using water for pressure drop and CO2 gas exchange. The best performing device was tested with fresh whole bovine blood for O2 exchange. Three μALs were successfully manufactured and passed leak testing. The top performing device had 15 alternating blood and gas layers. It oxygenated blood from 70% saturation to 95% saturation at a blood flow of 3 mL min-1 and blood side pressure drop of 234 mmHg. This new roll-to-roll manufacturing system is suitable for the automated construction of multi-layer microfluidic devices that are difficult to manufacture by conventional means. With some upgrades and improvements, this technology should allow for the automatic creation of large surface area microfluidic devices that can be employed for various applications including large-scale membrane gas exchange such as clinical-scale microfluidic artificial lungs.
Collapse
Affiliation(s)
- Andrew Zhang
- ECLS Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA.
- Ann Arbor Veteran Affairs Healthcare System, Ann Arbor, MI 48105, USA
| | - Kartik Tharwani
- ECLS Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA.
| | - Jennifer Wang
- ECLS Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA.
| | - Gabriele K Seilo
- ECLS Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA.
| | - Michael A Atie
- ECLS Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA.
- Ann Arbor Veteran Affairs Healthcare System, Ann Arbor, MI 48105, USA
| | - Joseph A Potkay
- ECLS Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA.
- Ann Arbor Veteran Affairs Healthcare System, Ann Arbor, MI 48105, USA
| |
Collapse
|
4
|
Yang M, Silva R, Zhao K, Ding R, Foo JLC, Ge L, Lisak G. Corrective protocol to predict interference free sensor response for paper-based solution sampling coupled with heavy metal sensitive ion-selective electrodes. Analyst 2024; 149:4351-4362. [PMID: 39005217 DOI: 10.1039/d4an00841c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/16/2024]
Abstract
Paper-based microfluidics combined with potentiometric measurement has emerged as an attractive approach for detecting various chemical ionic moieties. Detection of heavy metal ions, using paper substrates as solution sampling and delivery systems remains challenging despite efforts to introduce several physico-chemical paper substrate modifications to stop adsorption of ions onto the paper substrates. This study quantitatively investigates the adsorption of heavy metal ions on the paper substrates during paper-based potentiometric measurements and explains the super-Nernstian response of potentiometric sensors through local depletion of heavy metal ions from the solution. Consequently, based on the investigated ion adsorption, a corrective potential protocol was established for the electrodes coupled with paper-based solution sampling by predicting interference free sensor response from paper-based measurement. Furthermore, the ion adsorption was also recorded for mixed metal ion solutions to understand competitive primary/interfering ions adsorption onto the paper substrates and establish corrective measures to predict interference free sensor response. In this method, no modifications of the paper substrates are necessary before actual potentiometric measurements. The proposed corrective protocol allows prediction of sensor response based on the paper-based solution sampling potentiometric measurement, providing a simple methodological approach based on correction of potential readout of the potentiometric sensor, thus completely resigning from the need of modifying paper substrate for measurements of heavy metal ions.
Collapse
Affiliation(s)
- Mingpeng Yang
- School of Automation, Nanjing University of Information Science and Technology, 219 Ningliu Road, Nanjing 210044, China
- Residues and Resource Reclamation Centre, Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One, 637141, Singapore, Singapore.
- Jiangsu Collaborative Innovation Centre on Atmospheric Environment and Equipment Technology, Nanjing University of Information Science and Technology, 219 Ningliu Road, Nanjing 210044, China
| | - Rochelle Silva
- Residues and Resource Reclamation Centre, Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One, 637141, Singapore, Singapore.
- School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798, Singapore, Singapore
- Interdisciplinary Graduate Programme, Nanyang Technological University, 61 Nanyang Drive, Academic Block North, Singapore 637335, Singapore
| | - Ke Zhao
- Residues and Resource Reclamation Centre, Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One, 637141, Singapore, Singapore.
- School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798, Singapore, Singapore
| | - Ruiyu Ding
- Residues and Resource Reclamation Centre, Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One, 637141, Singapore, Singapore.
| | - Jit Loong Cyrus Foo
- Residues and Resource Reclamation Centre, Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One, 637141, Singapore, Singapore.
| | - Liya Ge
- Residues and Resource Reclamation Centre, Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One, 637141, Singapore, Singapore.
| | - Grzegorz Lisak
- Residues and Resource Reclamation Centre, Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One, 637141, Singapore, Singapore.
- School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798, Singapore, Singapore
| |
Collapse
|
5
|
Yang M, Sun N, Lai X, Zhao X, Zhou W. Advances in Non-Electrochemical Sensing of Human Sweat Biomarkers: From Sweat Sampling to Signal Reading. BIOSENSORS 2023; 14:17. [PMID: 38248394 PMCID: PMC10813192 DOI: 10.3390/bios14010017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 12/19/2023] [Accepted: 12/25/2023] [Indexed: 01/23/2024]
Abstract
Sweat, commonly referred to as the ultrafiltrate of blood plasma, is an essential physiological fluid in the human body. It contains a wide range of metabolites, electrolytes, and other biologically significant markers that are closely linked to human health. Compared to other bodily fluids, such as blood, sweat offers distinct advantages in terms of ease of collection and non-invasive detection. In recent years, considerable attention has been focused on wearable sweat sensors due to their potential for continuous monitoring of biomarkers. Electrochemical methods have been extensively used for in situ sweat biomarker analysis, as thoroughly reviewed by various researchers. This comprehensive review aims to provide an overview of recent advances in non-electrochemical methods for analyzing sweat, including colorimetric methods, fluorescence techniques, surface-enhanced Raman spectroscopy, and more. The review covers multiple aspects of non-electrochemical sweat analysis, encompassing sweat sampling methodologies, detection techniques, signal processing, and diverse applications. Furthermore, it highlights the current bottlenecks and challenges faced by non-electrochemical sensors, such as limitations and interference issues. Finally, the review concludes by offering insights into the prospects for non-electrochemical sensing technologies. By providing a valuable reference and inspiring researchers engaged in the field of sweat sensor development, this paper aspires to foster the creation of innovative and practical advancements in this domain.
Collapse
Affiliation(s)
- Mingpeng Yang
- School of Automation, Nanjing University of Information Science and Technology, 219 Ningliu Road, Nanjing 210044, China (X.Z.)
- Jiangsu Collaborative Innovation Centre on Atmospheric Environment and Equipment Technology, Nanjing University of Information Science and Technology, 219 Ningliu Road, Nanjing 210044, China
| | - Nan Sun
- School of Automation, Nanjing University of Information Science and Technology, 219 Ningliu Road, Nanjing 210044, China (X.Z.)
| | - Xiaochen Lai
- School of Automation, Nanjing University of Information Science and Technology, 219 Ningliu Road, Nanjing 210044, China (X.Z.)
- Jiangsu Collaborative Innovation Centre on Atmospheric Environment and Equipment Technology, Nanjing University of Information Science and Technology, 219 Ningliu Road, Nanjing 210044, China
| | - Xingqiang Zhao
- School of Automation, Nanjing University of Information Science and Technology, 219 Ningliu Road, Nanjing 210044, China (X.Z.)
- Jiangsu Collaborative Innovation Centre on Atmospheric Environment and Equipment Technology, Nanjing University of Information Science and Technology, 219 Ningliu Road, Nanjing 210044, China
| | - Wangping Zhou
- School of Automation, Nanjing University of Information Science and Technology, 219 Ningliu Road, Nanjing 210044, China (X.Z.)
- Jiangsu Collaborative Innovation Centre on Atmospheric Environment and Equipment Technology, Nanjing University of Information Science and Technology, 219 Ningliu Road, Nanjing 210044, China
| |
Collapse
|
6
|
Seo S, Kim T. Gas transport mechanisms through gas-permeable membranes in microfluidics: A perspective. BIOMICROFLUIDICS 2023; 17:061301. [PMID: 38025658 PMCID: PMC10656118 DOI: 10.1063/5.0169555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Accepted: 10/30/2023] [Indexed: 12/01/2023]
Abstract
Gas-permeable membranes (GPMs) and membrane-like micro-/nanostructures offer precise control over the transport of liquids, gases, and small molecules on microchips, which has led to the possibility of diverse applications, such as gas sensors, solution concentrators, and mixture separators. With the escalating demand for GPMs in microfluidics, this Perspective article aims to comprehensively categorize the transport mechanisms of gases through GPMs based on the penetrant type and the transport direction. We also provide a comprehensive review of recent advancements in GPM-integrated microfluidic devices, provide an overview of the fundamental mechanisms underlying gas transport through GPMs, and present future perspectives on the integration of GPMs in microfluidics. Furthermore, we address the current challenges associated with GPMs and GPM-integrated microfluidic devices, taking into consideration the intrinsic material properties and capabilities of GPMs. By tackling these challenges head-on, we believe that our perspectives can catalyze innovative advancements and help meet the evolving demands of microfluidic applications.
Collapse
Affiliation(s)
- Sangjin Seo
- Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50 UNIST-gil, Ulsan 44919, Republic of Korea
| | - Taesung Kim
- Author to whom correspondence should be addressed:. Tel.: +82-52-217-2313. Fax: +82-52-217-2409
| |
Collapse
|
7
|
Khodaparastasgarabad N, Sonawane JM, Baghernavehsi H, Gong L, Liu L, Greener J. Microfluidic membraneless microbial fuel cells: new protocols for record power densities. LAB ON A CHIP 2023; 23:4201-4212. [PMID: 37702583 DOI: 10.1039/d3lc00387f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/14/2023]
Abstract
The main hurdle in leveraging microfluidic advantages in membraneless MFCs is their low electrode area-normalized power. For nearly a decade, maximum power densities have remained stagnant, while at the same time macrosystems continue to gather pace. To bridge this growing gap, we showcase a strategy that focuses on (i) technology improvements, (ii) establishment of record areal power densities, and (iii) presentation of different normalization methods that complement areal power densities and enable direct comparisons across all MFC scales. Using a pure-culture Geobacter sulfurreducens electroactive biofilm (EAB) in a new membraneless MFC that adheres to the strategy above, we observed optimal anode colonization, resulting in the highest recorded electrode areal power density for a microfluidic MFC of 3.88 W m-2 (24.37 kW m-3). We also consider new power normalization methods that may be more appropriate for comparison to other works. Normalized by the wetted cross-section area between electrodes accounts for constraints in electrode/electrolyte contact, resulting in power densities as high as 8.08 W m-2. Alternatively, we present a method to normalize by the flow rate to account for acetate supply, obtaining normalized energy recovery values of 0.025 kW h m-3. With these results, the performance gap between micro- and macroscale MFCs is closed, and a road map to move forward is presented.
Collapse
Affiliation(s)
| | - Jayesh M Sonawane
- Département de Chimie, Faculté des sciences et de génie, Université Laval, Québec City, QC, Canada.
| | - Haleh Baghernavehsi
- Département de Chimie, Faculté des sciences et de génie, Université Laval, Québec City, QC, Canada.
| | - Lingling Gong
- Département de Chimie, Faculté des sciences et de génie, Université Laval, Québec City, QC, Canada.
| | - Linlin Liu
- Département de Chimie, Faculté des sciences et de génie, Université Laval, Québec City, QC, Canada.
| | - Jesse Greener
- Département de Chimie, Faculté des sciences et de génie, Université Laval, Québec City, QC, Canada.
- CHU de Québec, Centre de recherche, Université Laval, 10 rue de l'Espinay, Québec, QC, Canada
| |
Collapse
|
8
|
Van Ombergen A, Chalupa‐Gantner F, Chansoria P, Colosimo BM, Costantini M, Domingos M, Dufour A, De Maria C, Groll J, Jungst T, Levato R, Malda J, Margarita A, Marquette C, Ovsianikov A, Petiot E, Read S, Surdo L, Swieszkowski W, Vozzi G, Windisch J, Zenobi‐Wong M, Gelinsky M. 3D Bioprinting in Microgravity: Opportunities, Challenges, and Possible Applications in Space. Adv Healthc Mater 2023; 12:e2300443. [PMID: 37353904 PMCID: PMC11468760 DOI: 10.1002/adhm.202300443] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 05/12/2023] [Indexed: 06/25/2023]
Abstract
3D bioprinting has developed tremendously in the last couple of years and enables the fabrication of simple, as well as complex, tissue models. The international space agencies have recognized the unique opportunities of these technologies for manufacturing cell and tissue models for basic research in space, in particular for investigating the effects of microgravity and cosmic radiation on different types of human tissues. In addition, bioprinting is capable of producing clinically applicable tissue grafts, and its implementation in space therefore can support the autonomous medical treatment options for astronauts in future long term and far-distant space missions. The article discusses opportunities but also challenges of operating different types of bioprinters under space conditions, mainly in microgravity. While some process steps, most of which involving the handling of liquids, are challenging under microgravity, this environment can help overcome problems such as cell sedimentation in low viscous bioinks. Hopefully, this publication will motivate more researchers to engage in the topic, with publicly available bioprinting opportunities becoming available at the International Space Station (ISS) in the imminent future.
Collapse
Affiliation(s)
- Angelique Van Ombergen
- SciSpacE TeamDirectorate of Human and Robotic Exploration Programmes (HRE)European Space Agency (ESA)Keplerlaan 1Noordwijk2201AGThe Netherlands
- ESA Topical Team on “3D Bioprinting of living tissue for utilization in space exploration and extraterrestrial human settlements”01307DresdenGermany
| | - Franziska Chalupa‐Gantner
- Research Group 3D Printing and BiofabricationInstitute of Materials Science and TechnologyAustrian Cluster for Tissue RegenerationTU WienGetreidemarkt 9/E308Vienna1060Austria
| | - Parth Chansoria
- Tissue Engineering + Biofabrication LaboratoryDepartment of Health Sciences and TechnologyETH Zurich Otto‐Stern‐Weg 7Zürich8093Switzerland
| | - Bianca Maria Colosimo
- ESA Topical Team on “3D Bioprinting of living tissue for utilization in space exploration and extraterrestrial human settlements”01307DresdenGermany
- Department of Mechanical EngineeringPolitecnico di MilanoVia La Masa 1Milano20156Italy
| | - Marco Costantini
- Institute of Physical ChemistryPolish Academy of SciencesUl. Kasprzaka 44/52Warsaw01–224Poland
| | - Marco Domingos
- ESA Topical Team on “3D Bioprinting of living tissue for utilization in space exploration and extraterrestrial human settlements”01307DresdenGermany
- Department of MechanicalAerospace and Civil EngineeringSchool of EngineeringFaculty of Science and Engineering & Henry Royce InstituteUniversity of ManchesterM13 9PLManchesterUK
| | - Alexandre Dufour
- 3d.FAB – ICBMSCNRS UMR 5246University Claude Bernard‐Lyon 1 and University of Lyon1 rue Victor GrignardVilleurbanne69100France
| | - Carmelo De Maria
- Department of Information Engineering (DII) and Research Center “E. Piaggio”University of PisaLargo Lucio Lazzarino 1Pisa56122Italy
| | - Jürgen Groll
- ESA Topical Team on “3D Bioprinting of living tissue for utilization in space exploration and extraterrestrial human settlements”01307DresdenGermany
- Department of Functional Materials in Medicine and Dentistry at the Institute of Functional Materials and Biofabrication (IFB) and Bavarian Polymer Institute (BPI)University of WürzburgPleicherwall 297070WürzburgGermany
| | - Tomasz Jungst
- Department of Functional Materials in Medicine and Dentistry at the Institute of Functional Materials and Biofabrication (IFB) and Bavarian Polymer Institute (BPI)University of WürzburgPleicherwall 297070WürzburgGermany
| | - Riccardo Levato
- Department of OrthopaedicsUniversity Medical Center UtrechtDepartment of Clinical SciencesFaculty of Veterinary MedicineUtrecht UniversityUtrecht3584 CXThe Netherlands
| | - Jos Malda
- ESA Topical Team on “3D Bioprinting of living tissue for utilization in space exploration and extraterrestrial human settlements”01307DresdenGermany
- Department of OrthopaedicsUniversity Medical Center UtrechtDepartment of Clinical SciencesFaculty of Veterinary MedicineUtrecht UniversityUtrecht3584 CXThe Netherlands
| | - Alessandro Margarita
- Department of Mechanical EngineeringPolitecnico di MilanoVia La Masa 1Milano20156Italy
| | - Christophe Marquette
- ESA Topical Team on “3D Bioprinting of living tissue for utilization in space exploration and extraterrestrial human settlements”01307DresdenGermany
- 3d.FAB – ICBMSCNRS UMR 5246University Claude Bernard‐Lyon 1 and University of Lyon1 rue Victor GrignardVilleurbanne69100France
| | - Aleksandr Ovsianikov
- ESA Topical Team on “3D Bioprinting of living tissue for utilization in space exploration and extraterrestrial human settlements”01307DresdenGermany
- Research Group 3D Printing and BiofabricationInstitute of Materials Science and TechnologyAustrian Cluster for Tissue RegenerationTU WienGetreidemarkt 9/E308Vienna1060Austria
| | - Emma Petiot
- 3d.FAB – ICBMSCNRS UMR 5246University Claude Bernard‐Lyon 1 and University of Lyon1 rue Victor GrignardVilleurbanne69100France
| | - Sophia Read
- Department of MechanicalAerospace and Civil EngineeringSchool of EngineeringFaculty of Science and Engineering & Henry Royce InstituteUniversity of ManchesterM13 9PLManchesterUK
| | - Leonardo Surdo
- ESA Topical Team on “3D Bioprinting of living tissue for utilization in space exploration and extraterrestrial human settlements”01307DresdenGermany
- Space Applications Services NV/SA for the European Space Agency (ESA)Keplerlaan 1Noordwijk2201AGThe Netherlands
| | - Wojciech Swieszkowski
- ESA Topical Team on “3D Bioprinting of living tissue for utilization in space exploration and extraterrestrial human settlements”01307DresdenGermany
- Biomaterials GroupMaterials Design DivisionFaculty of Materials Science and EngineeringWarsaw University of TechnologyWoloska Str. 141Warsaw02–507Poland
| | - Giovanni Vozzi
- ESA Topical Team on “3D Bioprinting of living tissue for utilization in space exploration and extraterrestrial human settlements”01307DresdenGermany
- Department of Information Engineering (DII) and Research Center “E. Piaggio”University of PisaLargo Lucio Lazzarino 1Pisa56122Italy
| | - Johannes Windisch
- Centre for Translational BoneJoint and Soft Tissue ResearchUniversity Hospital and Faculty of Medicine Carl Gustav CarusTechnische Universität DresdenFetscherstr. 7401307DresdenGermany
| | - Marcy Zenobi‐Wong
- ESA Topical Team on “3D Bioprinting of living tissue for utilization in space exploration and extraterrestrial human settlements”01307DresdenGermany
- Tissue Engineering + Biofabrication LaboratoryDepartment of Health Sciences and TechnologyETH Zurich Otto‐Stern‐Weg 7Zürich8093Switzerland
| | - Michael Gelinsky
- ESA Topical Team on “3D Bioprinting of living tissue for utilization in space exploration and extraterrestrial human settlements”01307DresdenGermany
- Centre for Translational BoneJoint and Soft Tissue ResearchUniversity Hospital and Faculty of Medicine Carl Gustav CarusTechnische Universität DresdenFetscherstr. 7401307DresdenGermany
| |
Collapse
|
9
|
Brandl S, Reindl M. Blood-Brain Barrier Breakdown in Neuroinflammation: Current In Vitro Models. Int J Mol Sci 2023; 24:12699. [PMID: 37628879 PMCID: PMC10454051 DOI: 10.3390/ijms241612699] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 08/07/2023] [Accepted: 08/08/2023] [Indexed: 08/27/2023] Open
Abstract
The blood-brain barrier, which is formed by tightly interconnected microvascular endothelial cells, separates the brain from the peripheral circulation. Together with other central nervous system-resident cell types, including pericytes and astrocytes, the blood-brain barrier forms the neurovascular unit. Upon neuroinflammation, this barrier becomes leaky, allowing molecules and cells to enter the brain and to potentially harm the tissue of the central nervous system. Despite the significance of animal models in research, they may not always adequately reflect human pathophysiology. Therefore, human models are needed. This review will provide an overview of the blood-brain barrier in terms of both health and disease. It will describe all key elements of the in vitro models and will explore how different compositions can be utilized to effectively model a variety of neuroinflammatory conditions. Furthermore, it will explore the existing types of models that are used in basic research to study the respective pathologies thus far.
Collapse
Affiliation(s)
| | - Markus Reindl
- Clinical Department of Neurology, Medical University of Innsbruck, 6020 Innsbruck, Austria;
| |
Collapse
|
10
|
Yang M, Sun N, Lai X, Wu J, Wu L, Zhao X, Feng L. Paper-Based Sandwich-Structured Wearable Sensor with Sebum Filtering for Continuous Detection of Sweat pH. ACS Sens 2023; 8:176-186. [PMID: 36604942 DOI: 10.1021/acssensors.2c02016] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Wearable sweat sensors, a product of the development of flexible electronics and microfluidic technologies, can continuously and noninvasively monitor abundant biomarkers in human sweat; however, sweat interferences, such as sebum, can reduce sensor reliability and accuracy. Herein, for the first time, the influence of sebum on the potentiometric response of an all-solid-state pH sensor was studied, and the obtained experimental results show that sebum mixed in sweat can decrease the potential response of the sensor and the slope of its calibration curve. A paper-based sandwich-structured pH sensor that can filter the sebum mixed in sweat was proposed based on commonly used oil-control sheets. Moreover, the hydrophilic properties, microstructure, and microfluidic performance of the sensor were investigated. The detection performance of the paper-based sandwich-structured pH sensor was comprehensively evaluated in terms of calibration in the presence of sebum and potentiometric response upon the addition of sebum. Furthermore, the anti-interference ability of the sensor was evaluated using different analytes under various deformation conditions. On-body trials were conducted to verify the performance, and their results showed that the proposed sensor can filter over 90% of the sebum in sweat, significantly enhancing sensor reliability and accuracy. Additionally, microfluidic channels could be simply fabricated using a scissor and paper, obviating the need for complex micromachining processes, such as photolithography and laser engraving. Overall, this work illustrates the influence of sebum on the detection performance of traditional potentiometric wearable sensors and paves the way for their development for real-world applications.
Collapse
Affiliation(s)
- Mingpeng Yang
- School of Automation, Nanjing University of Information Science and Technology, Nanjing 210044, China.,Jiangsu Collaborative Innovation Centre on Atmospheric Environment and Equipment Technology, Nanjing University of Information Science and Technology, Nanjing 210044, China
| | - Nan Sun
- School of Automation, Nanjing University of Information Science and Technology, Nanjing 210044, China
| | - Xiaochen Lai
- School of Automation, Nanjing University of Information Science and Technology, Nanjing 210044, China
| | - Jiamin Wu
- Zhenyuan Applied Meteorological Research Institute, Nanjing 211100, China
| | - Lifan Wu
- College of Electrical Engineering and Control Science, Nanjing Tech University, Nanjing 211816, China
| | - Xingqiang Zhao
- School of Automation, Nanjing University of Information Science and Technology, Nanjing 210044, China
| | - Lihang Feng
- College of Electrical Engineering and Control Science, Nanjing Tech University, Nanjing 211816, China
| |
Collapse
|
11
|
Lai X, Yang M, Wu H, Li D. Modular Microfluidics: Current Status and Future Prospects. MICROMACHINES 2022; 13:1363. [PMID: 36014285 PMCID: PMC9414757 DOI: 10.3390/mi13081363] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 08/15/2022] [Accepted: 08/17/2022] [Indexed: 06/15/2023]
Abstract
This review mainly studies the development status, limitations, and future directions of modular microfluidic systems. Microfluidic technology is an important tool platform for scientific research and plays an important role in various fields. With the continuous development of microfluidic applications, conventional monolithic microfluidic chips show more and more limitations. A modular microfluidic system is a system composed of interconnected, independent modular microfluidic chips, which are easy to use, highly customizable, and on-site deployable. In this paper, the current forms of modular microfluidic systems are classified and studied. The popular fabrication techniques for modular blocks, the major application scenarios of modular microfluidics, and the limitations of modular techniques are also discussed. Lastly, this review provides prospects for the future direction of modular microfluidic technologies.
Collapse
Affiliation(s)
- Xiaochen Lai
- School of Automation, Nanjing University of Information Science & Technology, Nanjing 210044, China
| | - Mingpeng Yang
- School of Automation, Nanjing University of Information Science & Technology, Nanjing 210044, China
| | - Hao Wu
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
| | - Dachao Li
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
| |
Collapse
|