1
|
Trius-Soler M, Praticò G, Gürdeniz G, Garcia-Aloy M, Canali R, Fausta N, Brouwer-Brolsma EM, Andrés-Lacueva C, Dragsted LO. Biomarkers of moderate alcohol intake and alcoholic beverages: a systematic literature review. GENES & NUTRITION 2023; 18:7. [PMID: 37076809 PMCID: PMC10114415 DOI: 10.1186/s12263-023-00726-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Accepted: 04/04/2023] [Indexed: 04/21/2023]
Abstract
The predominant source of alcohol in the diet is alcoholic beverages, including beer, wine, spirits and liquors, sweet wine, and ciders. Self-reported alcohol intakes are likely to be influenced by measurement error, thus affecting the accuracy and precision of currently established epidemiological associations between alcohol itself, alcoholic beverage consumption, and health or disease. Therefore, a more objective assessment of alcohol intake would be very valuable, which may be established through biomarkers of food intake (BFIs). Several direct and indirect alcohol intake biomarkers have been proposed in forensic and clinical contexts to assess recent or longer-term intakes. Protocols for performing systematic reviews in this field, as well as for assessing the validity of candidate BFIs, have been developed within the Food Biomarker Alliance (FoodBAll) project. The aim of this systematic review is to list and validate biomarkers of ethanol intake per se excluding markers of abuse, but including biomarkers related to common categories of alcoholic beverages. Validation of the proposed candidate biomarker(s) for alcohol itself and for each alcoholic beverage was done according to the published guideline for biomarker reviews. In conclusion, common biomarkers of alcohol intake, e.g., as ethyl glucuronide, ethyl sulfate, fatty acid ethyl esters, and phosphatidyl ethanol, show considerable inter-individual response, especially at low to moderate intakes, and need further development and improved validation, while BFIs for beer and wine are highly promising and may help in more accurate intake assessments for these specific beverages.
Collapse
Affiliation(s)
- Marta Trius-Soler
- Department of Nutrition, Exercise and Sports, Faculty of Science, University of Copenhagen, 1958, Frederiksberg C, Denmark
- Polyphenol Research Laboratory, Department of Nutrition, Food Sciences and Gastronomy, XIA School of Pharmacy and Food Sciences, University of Barcelona, 08028, Barcelona, Spain
- INSA-UB, Nutrition and Food Safety Research Institute, University of Barcelona, 08921, Santa Coloma de Gramanet, Spain
- Centro de Investigación Biomédica en Red de Fisiopatología de La Obesidad Y Nutrición (CIBEROBN), Instituto de Salud Carlos III, 28029, Madrid, Spain
| | - Giulia Praticò
- Department of Nutrition, Exercise and Sports, Faculty of Science, University of Copenhagen, 1958, Frederiksberg C, Denmark
| | - Gözde Gürdeniz
- Department of Nutrition, Exercise and Sports, Faculty of Science, University of Copenhagen, 1958, Frederiksberg C, Denmark
| | - Mar Garcia-Aloy
- Biomarker & Nutrimetabolomics Laboratory, Department of Nutrition, Food Sciences and Gastronomy, Faculty of Pharmacy and Food Sciences, University of Barcelona, 08028, Barcelona, Spain
- Metabolomics Unit, Research and Innovation Centre, Fondazione Edmund Mach, San Michele All'Adige, Italy
| | - Raffaella Canali
- Consiglio Per La Ricerca in Agricoltura E L'analisi Dell'economia Agraria (CREA) Research Centre for Food and Nutrition, Rome, Italy
| | - Natella Fausta
- Consiglio Per La Ricerca in Agricoltura E L'analisi Dell'economia Agraria (CREA) Research Centre for Food and Nutrition, Rome, Italy
| | - Elske M Brouwer-Brolsma
- Division of Human Nutrition and Health, Department Agrotechnology and Food Sciences, Wageningen University and Research, P.O. Box 17, 6700 AA, Wageningen, The Netherlands
| | - Cristina Andrés-Lacueva
- INSA-UB, Nutrition and Food Safety Research Institute, University of Barcelona, 08921, Santa Coloma de Gramanet, Spain
- Biomarker & Nutrimetabolomics Laboratory, Department of Nutrition, Food Sciences and Gastronomy, Faculty of Pharmacy and Food Sciences, University of Barcelona, 08028, Barcelona, Spain
- Centro de Investigación Biomédica en Red de Fragilidad Y Envejecimiento Saludable (CIBERFES), Instituto de Salud Carlos III, 28029, Madrid, Spain
| | - Lars Ove Dragsted
- Department of Nutrition, Exercise and Sports, Faculty of Science, University of Copenhagen, 1958, Frederiksberg C, Denmark.
| |
Collapse
|
2
|
Herzog J, Skopp G, Musshoff F. Development and Validation of Seven Phosphatidylethanol Homologues in Dried Blood Spots Including Preliminary Results after Excessive Use of an Ethanol-Based Hand Sanitizer. J Anal Toxicol 2023; 47:245-252. [PMID: 36287059 PMCID: PMC9620346 DOI: 10.1093/jat/bkac086] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 10/19/2022] [Accepted: 10/25/2022] [Indexed: 11/13/2022] Open
Abstract
Phosphatidylethanol (PEth) has become a widespread marker offering an up to 4-week retrospective window to detect alcohol use. Due to the pandemic of coronavirus disease 2019, ethanol-based hand sanitizers are frequently used. The aim of this study was to develop and validate a method for the determination of up to seven different homologues of PEth from dried blood spots (DBSs) after use of an ethanol-based hand sanitizer. The objectives of its preliminary application were to prove whether a threshold of 20 ng/mL for PEth 16:0/18:1 is reached and whether other homologues are formed as well as if positive findings of urinary ethyl glucuronide (UEtG) can be observed with respect to assess monitoring of abstinence control programs. Ten volunteers (8 occasional and 2 regular drinkers) were recruited to excessively use an ethanol-based hand sanitizer on 5 successive days. DBSs and urine samples were collected daily. PEth and UEtG were determined by liquid chromatography--tandem mass spectrometry. In total, two volunteers with initial PEth 16:0/18:1 concentrations of 19.3 and 14.6 ng/mL exceeded the threshold of 20 ng/mL six times. Subjects drinking daily or almost daily had starting PEth 16:0/18:1 concentrations of 242 and 354 ng/mL, showing a decline of PEth concentrations in six out of the seven homologues over 5 days. In teetotalers, formation of PEth species could not be observed. Thus, not satisfying requirements in an alcohol monitoring program with initial PEth-negative blood cannot be explained by a frequent use of ethanol-based hand sanitizer only. In cases of regular alcohol consumption, PEth homologues are not likely to be further influenced. However, results indicated that individuals with a PEth concentration close to 20 ng/mL are at risk of exceeding the threshold by using ethanol-based hand sanitizer.
Collapse
Affiliation(s)
- Josefine Herzog
- Corresponding author: Josefine Herzog Forensic Toxicological Center (FTC) Munich Dessauerstr. 13-15, 80992 Munich, Germanye-Mail:
| | - Gisela Skopp
- Forensic Toxicological Center Munich, Munich, Germany
| | | |
Collapse
|
3
|
Beck O, Mellring M, Löwbeer C, Seferaj S, Helander A. Measurement of the alcohol biomarker phosphatidylethanol (PEth) in dried blood spots and venous blood-importance of inhibition of post-sampling formation from ethanol. Anal Bioanal Chem 2021; 413:5601-5606. [PMID: 33590314 PMCID: PMC8410693 DOI: 10.1007/s00216-021-03211-z] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Revised: 01/28/2021] [Accepted: 02/01/2021] [Indexed: 11/29/2022]
Abstract
Phosphatidylethanol (PEth) is a group of phospholipids formed in cell membranes following alcohol consumption by action of the enzyme phospholipase D (PLD). PEth measurement in whole blood samples is established as a specific alcohol biomarker with clinical and forensic applications. However, in blood specimens containing ethanol, formation of PEth may continue after sampling leading to falsely elevated concentrations. This study evaluated the use of dried blood spot (DBS) and microsampling specimens to avoid post-sampling formation of PEth. Filter paper cards and three commercial devices for volumetric microsampling of finger-pricked blood were assessed, using PEth-negative and PEth-positive whole blood fortified with 2 g/L ethanol. PEth (16:0/18:1) was measured by LC–MS/MS. Post-sampling formation of PEth occurred in wet blood and in the volumetric devices, but not filter paper cards, when stored at room temperature for 48 h. Addition of an inhibitor of PLD, sodium metavanadate (NaVO3), eliminated post-sampling formation during storage and drying. In conclusion, the present study confirmed previous observations that PEth can be formed in blood samples after collection, if the specimen contains ethanol. The results further demonstrated that post-sampling formation of PEth from ethanol also occurred with commercial devices for volumetric dried blood microsampling. In order for a PEth result not to be questioned, it is recommended to use a PLD inhibitor, whether venous blood is collected in a vacutainer tube or finger-pricked blood is obtained using devices for dried blood microsampling.
Collapse
Affiliation(s)
- Olof Beck
- Department of Clinical Neuroscience, Karolinska Institutet, 171 77, Stockholm, Sweden
| | | | - Christian Löwbeer
- SYNLAB Medilab, 183 34, Täby, Sweden.,Department of Laboratory Medicine, Karolinska Institutet, 141 86, Stockholm, Sweden
| | - Sabina Seferaj
- Department of Clinical Pharmacology, Karolinska University Laboratory, 141 86, Stockholm, Sweden
| | - Anders Helander
- Department of Laboratory Medicine, Karolinska Institutet, 141 86, Stockholm, Sweden. .,Department of Clinical Pharmacology, Karolinska University Laboratory, 141 86, Stockholm, Sweden.
| |
Collapse
|
4
|
Bollag WB, Olala LO, Xie D, Lu X, Qin H, Choudhary V, Patel R, Bogorad D, Estes A, Watsky M. Dioleoylphosphatidylglycerol Accelerates Corneal Epithelial Wound Healing. Invest Ophthalmol Vis Sci 2020; 61:29. [PMID: 32186673 PMCID: PMC7401755 DOI: 10.1167/iovs.61.3.29] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Purpose In contact with the external environment, the cornea can easily be injured. Although corneal wounds generally heal rapidly, the pain and increased risk of infection associated with a damaged cornea, as well as the impaired healing observed in some individuals, emphasize the need for novel treatments to accelerate corneal healing. We previously demonstrated in epidermal keratinocytes that the glycerol channel aquaporin-3 (AQP3) interacts with phospholipase D2 (PLD2) to produce the signaling phospholipid phosphatidylglycerol (PG), which has been shown to accelerate skin wound healing in vivo. We hypothesized that the same signaling pathway might be operational in corneal epithelial cells. Methods We used co-immunoprecipitation, immunohistochemistry, scratch wound healing assays in vitro, and corneal epithelial wound healing assays in vivo to determine the role of the AQP3/PLD2/PG signaling pathway in corneal epithelium. Results AQP3 was present in human corneas in situ, and AQP3 and PLD2 were co-immunoprecipitated from corneal epithelial cell lysates. The two proteins could also be co-immunoprecipitated from insect cells simultaneously infected with AQP3- and PLD2-expressing baculoviruses, suggesting a likely direct interaction. A particular PG, dioleoylphosphatidylglycerol (DOPG), enhanced scratch wound healing of a corneal epithelial monolayer in vitro. DOPG also accelerated corneal epithelial wound healing in vivo, both in wild-type mice and in a mouse model exhibiting impaired corneal wound healing (AQP3 knockout mice). Conclusions These results indicate the importance of the AQP3/PLD2/PG signaling pathway in corneal epithelial cells and suggest the possibility of developing DOPG as a pharmacologic therapy to enhance corneal wound healing in patients.
Collapse
|
5
|
Hill-Kapturczak N, Dougherty DM, Roache JD, Karns-Wright TE, Javors MA. Differences in the Synthesis and Elimination of Phosphatidylethanol 16:0/18:1 and 16:0/18:2 After Acute Doses of Alcohol. Alcohol Clin Exp Res 2018; 42:851-860. [PMID: 29505133 DOI: 10.1111/acer.13620] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Accepted: 02/25/2018] [Indexed: 11/27/2022]
Abstract
BACKGROUND The purpose of this study was to examine the synthesis and elimination of phosphatidylethanol (PEth) 16:0/18:1 and 16:0/18:2 following the consumption of alcohol among 56 light and heavy drinkers. METHODS A transdermal alcohol monitor was used to promote alcohol absence 7 days prior, and 14 days after, alcohol consumption in the laboratory. Participants consumed a 0.4 or 0.8 g/kg dose of alcohol in 15 minutes. Blood and breath samples were collected before, at various times up to 360 minutes postconsumption, and 2, 4, 7, 11, and 14 days after alcohol consumption. Initial rates of PEth synthesis, 360 minutes area under the PEth pharmacokinetic curves (AUCs), and elimination half-lives were determined. RESULTS (i) Nonzero PEth levels were observed before alcohol dosing for most participants, despite 7 days of alcohol use monitoring; (ii) 0.4 and 0.8 g/kg doses of alcohol produced proportional increases in PEth levels in all but 1 participant; (iii) the initial rate of synthesis of both PEth homologues did not differ between the 2 doses, but was greater for PEth 16:0/18:2 than PEth 16:0/18:1 at both doses; (iv) the mean AUC of both PEth homologues was higher at 0.8 g/kg than at 0.4 g/kg; (v) the mean AUC of 16:0/18:2 was greater than that of PEth 16:0/18:1 at both alcohol doses; (vi) the mean half-life of PEth 16:0/18:1 was longer than that of PEth 16:0/18:2 (7.8 ± 3.3 [SD] days and 6.4 ± 5.0 [SD] days, respectively); and (vii) there were no sex differences in PEth 16:0/18:1 or 16:0/18:2 pharmacokinetics. CONCLUSIONS The results of this study support the use of PEth 16:0/18:1 and 16:0/18:2 as biomarkers for alcohol consumption. Because of consistent pharmacokinetic differences, the levels of these 2 PEth homologues may provide more information regarding the quantity and recentness of alcohol consumption than either alone.
Collapse
Affiliation(s)
| | - Donald M Dougherty
- Department of Psychiatry, University of Texas Health Science Center, San Antonio, Texas.,Department of Pharmacology, University of Texas Health Science Center, San Antonio, Texas
| | - John D Roache
- Department of Psychiatry, University of Texas Health Science Center, San Antonio, Texas.,Department of Pharmacology, University of Texas Health Science Center, San Antonio, Texas
| | - Tara E Karns-Wright
- Department of Psychiatry, University of Texas Health Science Center, San Antonio, Texas
| | - Martin A Javors
- Department of Psychiatry, University of Texas Health Science Center, San Antonio, Texas.,Department of Pharmacology, University of Texas Health Science Center, San Antonio, Texas
| |
Collapse
|
6
|
Abstract
Fetal alcohol-spectrum disorders (FASDs) are a collection of physical and neurobehavioral disabilities caused by prenatal exposure to alcohol. To prevent or mitigate the costly effects of FASD, we must identify mothers at risk for having a child with FASD, so that we may reach them with interventions. Identifying mothers at risk is beneficial at all time points, whether prior to pregnancy, during pregnancy, or following the birth of the child. In this review, three approaches to identifying mothers at risk are explored: using characteristics of the mother and her pregnancy, using laboratory biomarkers, and using self-report assessment of alcohol-consumption risk. At present, all approaches have serious limitations. Research is needed to improve the sensitivity and specificity of biomarkers and screening instruments, and to link them to outcomes as opposed to exposure. Universal self-report screening of all women of childbearing potential should ideally be incorporated into routine obstetric and gynecologic care, followed by brief interventions, including education and personalized feedback for all who consume alcohol, and referral to treatment as indicated. Effective biomarkers or combinations of biomarkers may be used during pregnancy and at birth to determine maternal and fetal alcohol exposure. The combination of self-report and biomarker screening may help identify a greater proportion of women at risk for having a child with FASD, allowing them to access information and treatment, and empowering them to make decisions that benefit their children.
Collapse
Affiliation(s)
- Annika C Montag
- Department of Pediatrics, Division of Dysmorphology and Teratology, University of California San Diego, San Diego, CA, USA
| |
Collapse
|
7
|
Papas RK, Gakinya BN, Mwaniki MM, Keter AK, Lee H, Loxley MP, Klein DA, Sidle JE, Martino S, Baliddawa JB, Schlaudt KL, Maisto SA. Associations Between the Phosphatidylethanol Alcohol Biomarker and Self-Reported Alcohol Use in a Sample of HIV-Infected Outpatient Drinkers in Western Kenya. Alcohol Clin Exp Res 2016; 40:1779-87. [PMID: 27426424 DOI: 10.1111/acer.13132] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2015] [Accepted: 05/18/2016] [Indexed: 10/21/2022]
Abstract
BACKGROUND To counteract the syndemics of HIV and alcohol in Sub-Saharan Africa, international collaborations have developed interventions to reduce alcohol consumption. Reliable and accurate methods are needed to estimate alcohol use outcomes. A direct alcohol biomarker called phosphatidylethanol (PEth) has been shown to validate heavy, daily drinking, but the literature indicates mixed results for moderate and nondaily drinkers, including among HIV-infected populations. This study examined the associations of the PEth biomarker with self-report alcohol use at 2 time points in 127 HIV-infected outpatient drinkers in western Kenya. METHODS Participants were consecutively enrolled in a randomized clinical trial to test the efficacy of a behavioral intervention to reduce alcohol use in Eldoret, Kenya. They endorsed current alcohol use, and a minimum score of 3 on the Alcohol Use Disorders Identification Test-Consumption or consuming ≥6 drinks per occasion at least monthly in the past year. Study interviews and blood draws were conducted at baseline and at 3 months post treatment from July 2012 through September 2013. Alcohol use was assessed using the Timeline Followback questionnaire. Blood samples were analyzed for the presence of the PEth biomarker and were compared to self-reported alcohol use. We also conducted semistructured interviews with 14 study completers in February through March 2014. RESULTS Baseline data indicated an average of moderate-heavy alcohol use: 50% drinking days and a median of 4.5 drinks per drinking day. At baseline, 46% of women (31 of 67) and 8% of men (5 of 60) tested negative for PEth (p < 0.001). At the 3-month follow-up, 93% of women (25 of 27) and 97% of men (30 of 31) who reported drinking tested positive, while 70% of women (28 of 40) and 35% of men (10 of 29) who denied drinking tested negative for PEth. Interviews were consistent with self-reported alcohol use among 13 individuals with negative baseline results. CONCLUSIONS These results add to the growing literature showing lack of agreement between self-report and PEth results among unhealthy and nondaily drinkers, particularly women. More research is needed to determine at what level of consumption over what period of time PEth becomes a reliable and accurate indicator of alcohol use.
Collapse
Affiliation(s)
- Rebecca K Papas
- Alpert Medical School of Brown University, Providence, Rhode Island
| | - Benson N Gakinya
- School of Medicine, Moi University College of Health Sciences, Eldoret, Kenya
| | - Michael M Mwaniki
- Academic Model Providing Access to Healthcare (AMPATH), Eldoret, Kenya
| | - Alfred K Keter
- Academic Model Providing Access to Healthcare (AMPATH), Eldoret, Kenya
| | - Hana Lee
- Brown University School of Public Health, Providence, Rhode Island
| | | | | | - John E Sidle
- Indiana University School of Medicine, Indianapolis, Indiana
| | - Steve Martino
- Yale University School of Medicine, New Haven, Connecticut
| | - Joyce B Baliddawa
- School of Medicine, Moi University College of Health Sciences, Eldoret, Kenya
| | | | | |
Collapse
|
8
|
Bakhireva LN, Shrestha S, Gutierrez HL, Berry M, Schmitt C, Sarangarm D. Stability of Phosphatidylethanol in Dry Blood Spot Cards. Alcohol Alcohol 2015; 51:275-80. [PMID: 26519350 DOI: 10.1093/alcalc/agv120] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2015] [Accepted: 10/05/2015] [Indexed: 01/12/2023] Open
Abstract
BACKGROUND The analysis of phosphatidylethanol, a promising direct ethanol metabolite, in dry blood spots (PEth-DBS) is advantageous due to ease of storage, transportation and minimal invasiveness of capillary blood collection. One potential application of PEth-DBS is to confirm prenatal alcohol exposure in newborns suspected of FASD; however, stability of PEth-DBS is largely unknown. METHODS Phlebotomized samples from 31 adults with a history of alcoholism, admitted to the University of New Mexico Emergency Department, were analyzed for blood alcohol content and pipetted onto DBS cards (13 spots per patient). The first spot was analyzed within 2 weeks of collection for a baseline PEth; the remaining 12 spots were allocated into three temperature conditions (room temperature, 4°C, -80°C) for the repeated measures analysis. In addition, 5 newborn DBS samples with a baseline PEth>LOD were obtained from a prospective cohort at UNM and re-analyzed at 4 months after storage at -80°C. A mixed linear model was fitted to examine the effects of temperature, time and temperature-time interaction on PEth degradation over the first 9 months. RESULTS The baseline PEth levels were 592.8 ± 86.7 ng/ml and 18.3 ± 4.8 ng/ml in adult and newborn samples, respectively. All DBS samples remained positive in successive samples in all temperature conditions. Results of mixed linear model demonstrated a significant effect of temperature (P < 0.001) on PEth degradation over 9 months. CONCLUSIONS PEth-DBS appears to be relatively stable, especially when stored at lower temperatures. These initial results are encouraging and highlight the PEth-DBS potential in retrospective assessment of alcohol exposure.
Collapse
Affiliation(s)
- Ludmila N Bakhireva
- Department of Pharmacy Practice and Administrative Sciences, UNM, Albuquerque, NM, USA Department of Family and Community Medicine, UNM, Albuquerque, NM, USA
| | - Shikhar Shrestha
- Department of Pharmacy Practice and Administrative Sciences, UNM, Albuquerque, NM, USA
| | - Hilda L Gutierrez
- Department of Pharmacy Practice and Administrative Sciences, UNM, Albuquerque, NM, USA
| | - Mike Berry
- Department of Emergency Medicine, UNM, Albuquerque, NM, USA
| | - Cheryl Schmitt
- Department of Pharmacy Practice and Administrative Sciences, UNM, Albuquerque, NM, USA
| | | |
Collapse
|
9
|
Bakhireva LN, Leeman L, Savich RD, Cano S, Gutierrez H, Savage DD, Rayburn WF. The validity of phosphatidylethanol in dried blood spots of newborns for the identification of prenatal alcohol exposure. Alcohol Clin Exp Res 2014; 38:1078-85. [PMID: 24511895 DOI: 10.1111/acer.12349] [Citation(s) in RCA: 54] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2013] [Accepted: 11/18/2013] [Indexed: 12/15/2022]
Abstract
BACKGROUND Accurate identification of prenatal alcohol exposure (PAE) in the newborn period offers an opportunity for early identification of children at risk of future neurocognitive problems and the implementation of interventional approaches earlier in life. PAE newborn screening by measuring phosphatidylethanol in dried blood spot (PEth-DBS) cards is feasible, logistically easier, and more cost-efficient compared with other biomarkers. However, the sensitivity and specificity of this method have yet to be established. METHODS This prospective cohort study examined validity of PEth-DBS among 28 infants with PAE and 32 controls relative to maternal self-report and other biomarkers. Pregnant women were recruited from a University of New Mexico clinic and followed to early postpartum period. The composite index, which was based on self-reported measures of alcohol use and allowed to classify subjects into PAE and control groups, was the criterion measure used to estimate sensitivity and specificity of PEth-DBS. RESULTS The study included large proportions of patients representing ethnic minorities (7.4% American Indian, 81.7% Hispanic/Latina), low education (54.2% <high school), and unplanned pregnancy (90.0%). No differences in sociodemographic characteristics, smoking or illicit drug use were observed among the study groups. The sensitivity of maternal biomarkers (gamma glutamyltranspeptidase [GGT], % carbohydrate-deficient transferrin [%CDT], urine ethyl glucuronide [UEtG], urine ethyl sulfate [UEtS]) was low (<15%) reflecting a moderate chronic or intermittent binge pattern of drinking in this cohort. PEth-DBS demonstrated 100% specificity and the highest sensitivity (32.1%) compared with other biomarkers. A battery consisting of maternal direct ethanol metabolites (UEtG, UEtS, PEth) and newborn PEth-DBS increased sensitivity to 50% without a substantial drop in specificity (93.8%). CONCLUSIONS Newborn PEth-DBS is a highly specific biomarker and can facilitate accurate detection of PAE in conjunction with other biomarkers. Minimal invasiveness, ease of storage and transportation of DBS cards, absence of postcollection synthesis, cost savings, and potential integration with routine newborn screening are all unique advantages of this method.
Collapse
Affiliation(s)
- Ludmila N Bakhireva
- Department of Pharmacy Practice and Administrative Sciences, UNM, Albuquerque, New Mexico; Department of Family and Community Medicine, UNM, Albuquerque, New Mexico
| | | | | | | | | | | | | |
Collapse
|
10
|
Wurst FM, Thon N, Weinmann W, Yegles M, Preuss U. [What ethanol metabolites as biological markers tell us about alcohol use]. Wien Med Wochenschr 2013; 164:25-33. [PMID: 24322386 DOI: 10.1007/s10354-013-0254-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2013] [Accepted: 11/12/2013] [Indexed: 01/12/2023]
Abstract
Alcohol and tobacco related disorders are the two leading and most expensive causes of illness in central Europe. In addition to self reports and questionnaires, biomarkers are of relevance in diagnosis and therapy of alcohol use disorders. Traditional biomarkers such as gamma glutamyl transpeptidase or mean corpuscular volume are indirect biomarkers and are subject to influence of age, gender and non alcohol related diseases, among others.Direct ethanol metabolites such as ethyl glucuronide (EtG), ethyl sulphate (EtS) and phosphatidylethanol (PEth) are direct metabolites of ethanol, that are positive after intake of ethyl alcohol. They represent useful diagnostic tools for identifying alcohol use even more accurately than traditional biomarkers. Each of these drinking indicators remains positive in serum and urine for a characteristic time spectrum after the cessation of ethanol intake--EtG and EtS in urine up to 7 days, EtG in hair for months after ethanol has left the body. Applications include clinical routine use, emergency room settings, proof of abstinence in alcohol rehabilitation programs, driving under influence offenders, workplace testing, assessment of alcohol intake in the context of liver transplantation and fetal alcohol syndrome.
Collapse
Affiliation(s)
- Friedrich Martin Wurst
- Universitätsklinik für Psychiatrie und Psychotherapie II, Christian-Doppler-Klinik, Salzburger Landeskliniken, Paracelsus Medical University (PMU), Ignaz-Harrer-Straße 79, 5020, Salzburg, Österreich,
| | | | | | | | | |
Collapse
|
11
|
Bakhireva LN, Savich RD, Raisch DW, Cano S, Annett RD, Leeman L, Garg M, Goff C, Savage DD. The feasibility and cost of neonatal screening for prenatal alcohol exposure by measuring phosphatidylethanol in dried blood spots. Alcohol Clin Exp Res 2013; 37:1008-15. [PMID: 23421919 PMCID: PMC3661684 DOI: 10.1111/acer.12045] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2012] [Accepted: 10/30/2012] [Indexed: 11/28/2022]
Abstract
BACKGROUND Accurate confirmation of prenatal alcohol exposure (PAE) is required as a diagnostic criterion for the majority of children adversely affected by PAE who do not manifest the physical features associated with fetal alcohol syndrome. A number of ethanol biomarkers have been used to assess PAE, often with suboptimal results. The purpose of this study was to evaluate the feasibility and cost of PAE screening in newborns by measuring phosphatidylethanol (PEth) in dried blood spot (DBS) cards. METHODS The feasibility of collecting an additional DBS card during routine newborn screening and the background prevalence of PAE were evaluated in a de-identified sample of newborn children delivered at the University of New Mexico Hospital. Electronic orders to collect DBS cards from newborns who continue to bleed after the routine newborn screen, glucose, or hematocrit testing were initiated for all infants delivered during a 4-week time frame. Specimens were sent to a contract laboratory for PEth analysis by liquid chromatography-tandem mass spectrometry. A cost analysis was conducted to compare the cost of PAE screening by PEth in DBS versus PEth in conventional blood specimens and by meconium fatty acid ethyl esters. RESULTS From 230 collected cards, 201 (87.4%) had at least 1 full blood spot (amount sufficient for PEth analysis), and 6.5% had PEth >20 ng/ml indicative of potential PAE in late pregnancy. PAE screening by PEth in DBS is logistically simpler and less expensive compared with 2 other screening approaches. CONCLUSIONS These results indicate that screening for PAE in DBS cards is a feasible procedure and that a majority of infants have enough blood after the routine heel prick to fill an additional card. Moreover, screening by PEth analysis from DBS cards is cost-efficient. The acceptability of such screening by parents and corresponding ethical issues remain to be investigated.
Collapse
Affiliation(s)
- Ludmila N Bakhireva
- Department of Pharmacy Practice and Administrative Sciences, University of New Mexico Health Sciences Center, Albuquerque, NM, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Viel G, Boscolo-Berto R, Cecchetto G, Fais P, Nalesso A, Ferrara SD. Phosphatidylethanol in blood as a marker of chronic alcohol use: a systematic review and meta-analysis. Int J Mol Sci 2012. [PMID: 23203094 PMCID: PMC3509610 DOI: 10.3390/ijms131114788] [Citation(s) in RCA: 157] [Impact Index Per Article: 13.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
The present paper aims at a systematic review of the current knowledge on phosphatidylethanol (PEth) in blood as a direct marker of chronic alcohol use and abuse. In March 2012, the search through “MeSH” and “free-text” protocols in the databases Medline/PubMed, SCOPUS, Web of Science, and Ovid/Embase, combining the terms phosphatidylethanol and alcohol, provided 444 records, 58 of which fulfilled the inclusion criteria and were used to summarize the current evidence on the formation, distribution and degradation of PEth in human blood: (1), the presence and distribution of different PEth molecular species (2), the most diffused analytical methods devoted to PEth identification and quantization (3), the clinical efficiency of total PEth quantification as a marker of chronic excessive drinking (4), and the potential utility of this marker for identifying binge drinking behaviors (5). Twelve papers were included in the meta-analysis and the mean (M) and 95% confidence interval (CI) of total PEth concentrations in social drinkers (DAI ≤ 60 g/die; M = 0.288 μM; CI 0.208–0.367 μM) and heavy drinkers (DAI > 60 g/die; M = 3.897 μM; CI 2.404–5.391 μM) were calculated. The present analysis demonstrates a good clinical efficiency of PEth for detecting chronic heavy drinking.
Collapse
Affiliation(s)
- Guido Viel
- Authors to whom correspondence should be addressed; E-Mails: (G.V.); (R.B.-B.); Tel.: +39-049-827-2230; Fax: +39-049-663155
| | - Rafael Boscolo-Berto
- Authors to whom correspondence should be addressed; E-Mails: (G.V.); (R.B.-B.); Tel.: +39-049-827-2230; Fax: +39-049-663155
| | | | | | | | | |
Collapse
|
13
|
Stewart SH, Reuben A, Brzezinski WA, Koch DG, Basile J, Randall PK, Miller PM. Preliminary evaluation of phosphatidylethanol and alcohol consumption in patients with liver disease and hypertension. Alcohol Alcohol 2009; 44:464-7. [PMID: 19535495 DOI: 10.1093/alcalc/agp039] [Citation(s) in RCA: 72] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
AIMS The goal of this preliminary study was to evaluate the relationship between blood phosphatidylethanol (PEth) and recent drinking in patients with liver disease and hypertension. METHODS Twenty-one patients with liver disease and 21 patients with essential hypertension were recruited at an academic medical center. Alcohol consumption was estimated using validated self-report methods, and blood PEth was measured by HPLC-MS/MS at a contracted laboratory. Nonparametric comparisons were made between abstainers/light drinkers, moderate drinkers consuming between 1 and 3 drinks per day, and those drinking above this level. Regression methods were used to estimate the effects of liver disease, gender, and age on the relationship between PEth and alcohol use, and to estimate the strength of the linear relationship between PEth and drinking. RESULTS PEth differed significantly between the three drinking groups (P < 0.001). The relationship between PEth and alcohol did not differ between hypertension and liver disease patients (P = 0.696), nor by gender and age. While there was substantial variability between subjects in the PEth concentration given a similar level of reported drinking, the amount of ethanol consumed was strongly associated with the PEth concentration (P < 0.001). CONCLUSION Results support PEth measurement by HPLC-MS/MS as a promising marker of past 1- to 2-week moderate to heavy alcohol consumption in patients with and without liver disease. PEth appears useful for differentiating abstinence or light drinking from moderate to heavy consumption, but may have limited utility for differentiating moderate from heavy alcohol use.
Collapse
Affiliation(s)
- Scott H Stewart
- Medical University of South Carolina, Charleston, 29425, USA.
| | | | | | | | | | | | | |
Collapse
|