1
|
Su CY, Yeh LK, Huang PH, Lin WP, Huang HF, Lai CC, Fang HW. Long-term effects of tear film component deposition on the surface and optical properties of two different orthokeratology lenses. Cont Lens Anterior Eye 2023; 46:101852. [PMID: 37150645 DOI: 10.1016/j.clae.2023.101852] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 03/08/2023] [Accepted: 04/28/2023] [Indexed: 05/09/2023]
Abstract
PURPOSE To understand the effects of long-term deposition of tear film components on the surface and optical properties of orthokeratology (ortho-k) lenses, two different lenses, Brighten 22 and Optimum Extra, were tested here. METHODS Ortho-k lenses were immersed in artificial tears and cleaned with a commercial care solution repeatedly for up to 90 days. Both the daily and accumulated lysozyme deposition amounts using an Enzyme-Linked ImmunoSorbent Assay were then analyzed. The base curve, central thickness, power, and transmission of visible light, ultraviolet A, and ultraviolet B were analyzed before and after repeated tear film component deposition procedures. The surface roughness using atomic force microscopy was observed and an energy dispersive spectrometer was used to analyze the composition of the deposits. RESULTS The highest levels of lysozyme were adsorbed on both lens materials during the first four days of the procedure and became saturated by day 6. For both lens materials, contamination on the lenses was easily observed by day 30, and the degree of surface roughness was higher. The transmission levels of different light spectrums were reduced showing that the optical characteristics of both lenses were also affected. CONCLUSIONS The results provide in vitro evidence that lysozyme could not be completely removed from orthokeratology lenses. Both surface and optical properties were affected by the deposition of tear film components. However, only one commercial multipurpose care solution was used to clean the lens in this study when the main ingredient was a surfactant, and the results might be different when other care regimens with other key ingredients are used. In addition, whether tear film component deposition might result in increased risks of infection or corneal abrasion will require further investigation.
Collapse
Affiliation(s)
- Chen-Ying Su
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology. 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan
| | - Lung-Kun Yeh
- Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou, No. 5, Fuxing St., Taoyuan 333, Taiwan; College of Medicine, Chang Gung University, No. 259, Wenhua 1st Rd., Taoyuan 333, Taiwan
| | - Pin-Hsuan Huang
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology. 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan
| | - Wen-Pin Lin
- Research and Development Center, Brighten Optix Co., 6F-1, No. 150, Sec.4, Chengde Rd., Shilin Dist., Taipei 111, Taiwan; Department of Optometry, University of Kang Ning, No. 137, Alley 75, Sec. 3, Kang Ning Road, Neihu District, Taipei 11485, Taiwan
| | - Hsueh-Fang Huang
- Research and Development Center, Brighten Optix Co., 6F-1, No. 150, Sec.4, Chengde Rd., Shilin Dist., Taipei 111, Taiwan
| | - Chi-Chun Lai
- Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou, No. 5, Fuxing St., Taoyuan 333, Taiwan; College of Medicine, Chang Gung University, No. 259, Wenhua 1st Rd., Taoyuan 333, Taiwan
| | - Hsu-Wei Fang
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology. 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan; Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, No. 35, Keyan Road, Zhunan Town, Miaoli County 35053, Taiwan.
| |
Collapse
|
2
|
Kalaiselvan P, Dutta D, Konda NV, Sharma S, Kumar N, Stapleton F, Willcox MDP. Effect of Deposition and Protease Digestion on the Ex Vivo Activity of Antimicrobial Peptide-Coated Contact Lenses. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:349. [PMID: 36678102 PMCID: PMC9863661 DOI: 10.3390/nano13020349] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 01/11/2023] [Accepted: 01/12/2023] [Indexed: 06/17/2023]
Abstract
A clinical study of antimicrobial contact lenses containing the cationic peptide Mel4 was conducted. The few adverse events that occurred with this lens occurred on or after 13 nights of wear. The current study examined whether the Mel4 contact lenses lost activity during wear and the mechanism of this loss. Participants wore contact lenses for up to 13 nights. Lenses were tested for their ability to reduce the adhesion of Pseudomonas aeruginosa and Staphylococcus aureus. The amount of protein and lipid extracted from lenses was measured. The ability of trypsin to affect the antimicrobial activity of Mel4-coated contact lenses was measured. Mel4-coated contact lenses lost their antimicrobial activity at six nights of wear for both bacteria. The amount of lipids (13 ± 11 vs. 21 ± 14 μg/lens at 13 nights wear) and proteins (8 ± 4 vs. 10 ± 3 mg/lens at 13 nights of wear) extracted from lenses was not different between Mel4-coated and uncoated lenses, and was not different after three nights when antimicrobial activity was maintained and thirteen nights when they had lost activity (lipid: 25 ± 17 vs. 13 ± 11, p = 0.2; protein: 8 ± 1 vs. 8 ± 4 mg/lens, p = 0.4). Trypsin digestion eliminated the antimicrobial activity of Mel4-coated lenses. In summary, Mel4-coated contact lenses lost antibacterial activity at six nights of wear, and the most likely reason was proteolytic digestion of the peptide. Future studies will design and test proteolytically stable peptide mimics as coatings for contact lenses.
Collapse
Affiliation(s)
| | - Debarun Dutta
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW 2052, Australia
- School of Optometry, Aston University, Birmingham B4 7ET, UK
| | - Nagaraju V. Konda
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW 2052, Australia
- School of Medical Sciences, University of Hyderabad, Hyderabad 500046, Telangana, India
| | - Savitri Sharma
- Jhaveri Microbiology Centre, L. V. Prasad Eye Institute, Hyderabad 500034, Telangana, India
| | - Naresh Kumar
- School of Chemistry, UNSW Sydney, Sydney, NSW 2052, Australia
| | - Fiona Stapleton
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW 2052, Australia
| | - Mark D. P. Willcox
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW 2052, Australia
| |
Collapse
|
3
|
Xu Y, Li H. In vitro and in vivo evaluation of brimonidine loaded silica nanoparticles-laden silicone contact lenses to manage glaucoma. J Biomater Appl 2022; 37:333-343. [PMID: 35482359 DOI: 10.1177/08853282221090880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Glaucoma is treated by frequent instillation of 0.2% w/v brimonidine tartrate eye drop solution, which showed poor ocular bioavailability of 1-3%. Medicated contact lenses can be used to improve the ocular drug bioavailability. However, drug loading in the contact lens matrix showed high burst release and changes the optophysical properties of the contact lens material. In this paper, a novel brimonidine loaded silica nanoparticles-laden silicone contact lenses (Bri-Si) were designed to achieve controlled drug delivery without altering the optophysical properties of the contact lens. Silica nanoparticles were prepared by polymerizing octadecyltrimethoxysilane (OTMS) molecules at the oil/water interface of microemulsion. Traditional soaking method (Bri-SM), direct brimonidine-loading method (Bri-DL) and microemulsion-laden contact lens (Bri-ME) were developed for comparison. The Bri-Si lens showed improved swelling, transmittance, oxygen permeability and lysozyme adherence compared to Bri-SM, Bri-DL and Bri-ME lenses. The Bri-DL lens showed high brimonidine leaching during extraction and sterilization steps, with low cumulative drug release. While, Bri-Si lens show controlled brimonidine release for 144 h. In a rabbit tear fluid model, the Bri-Si lens showed high brimonidine concentration for 96 h compared to Bri-ME lens and eye drop therapy. Based on histopathological studies of cornea, the Bri-Si lens was found to be safe for human applications. The data demonstrated the novel application of silica nanoparticles to control brimonidine release from the contact lens without altering the optophysical properties of the contact lens.
Collapse
Affiliation(s)
- Yunli Xu
- Department of Ophtalmology, 74723Zhenjiang Hospital Affiliated to Nanjing University of Chinese Medicine (Zhenjiang Hospital of Traditional Chinese Medicine), Zhenjiang, Jiangsu Province, 212008, China
| | - Hongyi Li
- Department of Ophtalmology, 12432Heilongjiang University Hospital, Heilongjiang University, Harbin, Heilongjiang Province, 150080, China
| |
Collapse
|
4
|
Xue Y, Gao Q, Zhang L. Extended ocular delivery of latanoprost from niosome-laden contact lenses: In vitro characterization and in vivo studies. J Drug Deliv Sci Technol 2022. [DOI: 10.1016/j.jddst.2021.103044] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
5
|
Masoudi S, Willcox M. Development of an enzymatic method for the evaluation of protein deposition on contact lenses. BIOFOULING 2022; 38:84-99. [PMID: 35016572 DOI: 10.1080/08927014.2021.2019225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 12/09/2021] [Accepted: 12/10/2021] [Indexed: 06/14/2023]
Abstract
The aim of this study was to evaluate a new digestion method to quantify protein deposition on contact lenses. Four silicone hydrogel and one hydrogel contact lens material were incubated in lactoferrin, lysozyme, immunoglobulin A, and bovine serum albumin solutions at approximate physiological concentrations and temperature. Immobilized trypsin was used to digest the protein deposits from the contact lens surfaces. The total protein absorbed to lenses was extracted and digested using sequencing grade trypsin. The tryptic peptides were quantified using selected reaction monitoring mass spectrometry. The concentration of surface protein deposits was either lower than or the same as the total protein for all lens types and proteins. Immobilised trypsin can digest protein deposits from the surface of contact lenses. This ability to analyse the amount of protein at a contact lens surface may help in elucidating the effect of surface deposition on clinical outcomes during lens wear.
Collapse
Affiliation(s)
- Simin Masoudi
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| | - Mark Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| |
Collapse
|
6
|
Xiaojie H, Fagang J, Jun J, Chunfang W, Chengquan L, Xinghua W. Bimatoprost-Loaded Silica Shell-Coated Nanoparticles-Laden Soft Contact Lenses to Manage Glaucoma: In Vitro and In Vivo Studies. AAPS PharmSciTech 2021; 23:33. [PMID: 34950994 DOI: 10.1208/s12249-021-02199-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Accepted: 12/06/2021] [Indexed: 11/30/2022] Open
Abstract
Currently, glaucoma is managed by frequent instillation of bimatoprost eye drop therapy, which showed very poor ocular bioavailability. Contact lens is widely used as medical device to improve the drug retention on the ocular tissues. However, the traditional methods of drug loading in the contact lens matrix showed high burst release and changes the optophysical properties of the contact lens material. In this paper, a novel bimatoprost-loaded silica shell nanoparticles-laden soft contact lenses were developed to achieve sustain drug delivery without altering the optophysical properties of the contact lens. Silica-shell nanoparticles were prepared using octyltrimethoxysilane (OTMS) and microemulsion. Traditional soaking method (SM-BT), direct bimatoprost loading method (DL-BT), and microemulsion-laden contact lens (ME-BT) were developed for comparison. The silica shell-coated nanoparticles-laden soft contact lenses (SiS-BT) showed improved swelling, transmittance, oxygen permeability, and lysozyme adherence compared to SM-BT, DL-BT, and ME-BT lenses. The DL-BT and ME-BT batch showed high bimatoprost lost/leaching during extraction and sterilization steps, with low cumulative drug release. Also, SiS-BT lens showed sustain bimatoprost release for 96 h. In a rabbit tear fluid model, the SiS-BT lens showed high bimatoprost concentration for 72 h compared to ME-BT lens and eye drop therapy. Based on histopathological studies of cornea, the SiS-BT lens was found to be safe for human applications. The data demonstrated the novel application of silica shell nanoparticles to deliver bimatoprost from the contact lens for extended period of time without altering the optophysical properties of the contact lens.
Collapse
|
7
|
Liu J, Wang X. Ofloxacin-Loaded Niosome-Laden Contact Lens: Improved Properties of Biomaterial for Ocular Drug Delivery. AAPS PharmSciTech 2021; 23:6. [PMID: 34851496 DOI: 10.1208/s12249-021-02157-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Accepted: 10/04/2021] [Indexed: 12/17/2022] Open
Abstract
Currently, bacterial conjunctivitis is managed by multiple antibiotic eye-drop solution, which is highly inefficient due to low ocular bioavailability and frequent dosing. Therapeutic soft contact lenses can be used to sustain the release of ocular drugs. However, the conventional soaking method (economic and widely used) showed low drug uptake and high burst release, and the optophysical properties of the contact lens were altered for clinical application. In this paper, novel ofloxacin-loaded niosomes were developed to increase the drug loading capacity of contact lenses while also sustaining ocular drug delivery. Ofloxacin-loaded niosomes were prepared by the thin film hydration technique with three levels of cholesterol. The niosome-laden contact lenses (OFL-Nio-L) led to improved optophysical properties (swelling, transmittance, oxygen permeability) and lysozyme adherence compared to the conventional soaked contact lens (CV-OFL-L). The in vitro drug release data of CV-OFL-L showed high burst release, while OFL-Nio-L lenses showed sustained release up to 48-96 h. In a rabbit tear fluid model, the OFL-Nio-100-L lens showed a high drug concentration at all-time points compared to the CV-OFL-L and eye-drop solution. The efficacy study in the rabbit model showed improved healing effect with OFL-Nio-100-L lens compared to frequent eye-drop therapy. In conclusion, the paper demonstrated the successful application of niosomes to deliver ofloxacin using contact lens without affecting the critical lens properties to substitute eye-drop therapy.
Collapse
|
8
|
Heynen M, Ng A, Martell E, Subbaraman LN, Jones L. Activity of Deposited Lysozyme on Contemporary Soft Contact Lenses Exposed to Differing Lens Care Systems. Clin Ophthalmol 2021; 15:1727-1733. [PMID: 33935489 PMCID: PMC8079347 DOI: 10.2147/opth.s296116] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Accepted: 03/17/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose The amount of protein deposition on soft contact lenses and to what extent the proteins are denatured may have an impact on comfortable wearing times of contact lenses. The purpose of this study was to evaluate the effects of two lens care systems on total protein and the quantity and activity of lysozyme deposited on worn senofilcon A, silicone hydrogel contact lenses. Participants and Methods Thirty symptomatic soft contact lens wearers were enrolled into a 4-week prospective, randomized, bilateral eye, daily-wear, crossover, double-masked study. Participants were fitted with biweekly senofilcon A lenses and were assigned either a polyquaternium-1 and myristamidopropyl dimethylamine-containing system (OPTI-FREE RepleniSH) or a peroxide-based system (CLEAR CARE). After each wear period, proteins were extracted from the lenses and analyzed for total protein, total lysozyme quantity and activity. Results The use of either the peroxide-based system or the polyquaternium-1 and myristamidopropyl dimethylamine-containing system resulted in no difference (P>0.05) to the amount of total protein deposited on the lenses (6.7 ± 2.8 micrograms/lens versus 7.3 ± 2.8 micrograms/lens, respectively) or to the amount of denatured lysozyme deposits (0.8 ± 0.7 versus 0.9 ± 0.7 micrograms/lens), respectively. The total amount of lysozyme deposited on the lenses was significantly lower when using the peroxide-based system (1.3 ± 0.9 micrograms/lens) compared to the polyquaternium-1 and myristamidopropyl dimethylamine-containing system (1.7 ± 1.0 micrograms/lens) (P=0.02). Conclusion The inactivation of lysozyme deposited on senofilcon A lenses when disinfected with the peroxide-based or the polyquaternium-1 and myristamidopropyl dimethylamine-containing systems were neither statistically nor clinically significant and the overall amounts of denatured lysozyme recovered from the lenses were low (<1 microgram/lens).
Collapse
Affiliation(s)
- Miriam Heynen
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Alan Ng
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Elizabeth Martell
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Lakshman N Subbaraman
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Lyndon Jones
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada.,Centre for Eye and Vision Research (CEVR), Hong Kong Science Park, Hong Kong
| |
Collapse
|
9
|
Phan CM, Qiao H, Yee A, Jones L. Deposition of Fluorescently Tagged Lysozyme on Contact Lenses in a Physiological Blink Model. Eye Contact Lens 2021; 47:127-133. [PMID: 31789754 DOI: 10.1097/icl.0000000000000683] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/02/2019] [Indexed: 11/25/2022]
Abstract
PURPOSE To visualize the deposition of fluorescein isothiocyanate (FITC) lysozyme on daily disposable contact lenses (CLs) using a novel blink model. METHODS Three daily disposable conventional hydrogel CLs (etafilcon A, omafilcon A, and nelfilcon A) and three silicone hydrogel CLs (delefilcon A, senofilcon A, and somofilcon A) were evaluated in the study. The CLs were mounted onto a novel blink model and exposed to an artificial tear solution containing FITC lysozyme for 2 and 10 hr. The flow rate and blink speed were set to 1 μL/min and 6 blinks/min, respectively. After the incubation period, a 5-mm-diameter disc was punched out from the center of the lens and mounted on a microscope slide. The slides were imaged using the Zeiss 510 Meta confocal laser scanning microscope, which scanned the lens from the front to the back surface at 5-μm increments. RESULTS There was an increase in deposition of FITC lysozyme for all lens types with increasing incubation time (P<0.05), with the exception of somofilcon A, which did not show statistical significance between 2 and 10 hr (P>0.05). The conventional hydrogel CLs deposited higher amounts of FITC lysozyme than the silicone hydrogel CLs (P<0.001), with etafilcon A depositing the highest at all time points (P<0.05). Interestingly, at the 2-hr incubation time, most CLs showed a higher amount of deposition at the front surface than the back surface of the lens. In particular, etafilcon A showed preferred deposition at the front surface at all time points. CONCLUSION The results suggest that there is differential deposition at the front surface of the CL, which is exposed to the prelens tear film, compared with the back surface of the CL, which is exposed to the postlens tear film. Therefore, it may be beneficial to design CL materials with differing surface properties for the front and back surfaces of the CL to enhance interactions with the tear film and ocular surface.
Collapse
Affiliation(s)
- Chau-Minh Phan
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | | | | | | |
Collapse
|
10
|
Antifouling silicone hydrogel contact lenses via densely grafted phosphorylcholine polymers. Biointerphases 2020; 15:041013. [PMID: 32867505 DOI: 10.1116/6.0000366] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Silicone hydrogel contact lenses (CLs) permit increased oxygen permeability through their incorporation of siloxane functional groups. However, contact lens biofouling can be problematic with these materials; surface modification to increase lens compatibility is necessary for acceptable properties. This work focuses on the creation of an antifouling CL surface through a novel grafting method. A polymer incorporating 2-methacryloyloxyethyl phosphorylcholine (MPC), well known for its antifouling and biomimetic properties, was grafted to the model lens surfaces using surface-initiated atom transfer radical polymerization (SI-ATRP). The SI-ATRP modification generated a unique double-grafted polymeric architecture designed to resist protein adsorption through the presence of a surrounding hydration layer due to the PC groups and steric repulsion due to the density of the grafted chains. The polymer was grafted from model silicone hydrogel CL using a four-step SI-ATRP process. Attenuated total reflectance-Fourier transform infrared spectroscopy and XPS were used to confirm the surface chemical composition at each step of the synthesis. Both the surface wettability and equilibrium water content of the materials increased significantly upon polyMPC modification. The surface water contact angle was as low as 16.04 ± 2.37° for polyMPC-50 surfaces; complete wetting (∼0°) was observed for polyMPC-100 surfaces. A decrease in the protein adsorption by as much as 83% (p < 0.000 36) for lysozyme and 73% (p < 0.0076) for bovine serum albumin was observed, with no significant difference between different polyMPC chain lengths. The data demonstrate the potential of this novel modification process for the creation of extremely wettable and superior antifouling surfaces, useful for silicone hydrogel CL surfaces.
Collapse
|
11
|
Chang YC, Su CY, Chang CH, Fang HW, Wei Y. Correlation between Tribological Properties and the Quantified Structural Changes of Lysozyme on Poly (2-hydroxyethyl methacrylate) Contact Lens. Polymers (Basel) 2020; 12:polym12081639. [PMID: 32717989 PMCID: PMC7464607 DOI: 10.3390/polym12081639] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 07/17/2020] [Accepted: 07/17/2020] [Indexed: 12/23/2022] Open
Abstract
The ocular discomfort is the leading cause of contact lens wear discontinuation. Although the tear proteins as a lubricant might improve contact lens adaptation, some in vitro studies suggested that the amount of adsorbed proteins could not simply explain the lubricating performance of adsorbed proteins. The purpose of this study was to quantify the structural changes and corresponding ocular lubricating properties of adsorbed protein on a conventional contact lens material, poly (2-hydroxyethyl methacrylate) (pHEMA). The adsorption behaviors of lysozyme on pHEMA were determined by the combined effects of protein–surface and protein–protein interactions. Lysozyme, the most abundant protein in tear, was first adsorbed onto the pHEMA surface under widely varying protein solution concentrations to saturate the surface, with the areal density of the adsorbed protein presenting different protein–protein effects within the layer. These values were correlated with the measured secondary structures, and corresponding friction coefficient of the adsorbed and protein covered lens surface, respectively. The decreased friction coefficient value was an indicator of the lubricated surfaces with improved adaptation. Our results indicate that the protein–protein effects help stabilize the structure of adsorbed lysozyme on pHEMA with the raised friction coefficient measured critical for the innovation of contact lens material designs with improved adaptation.
Collapse
Affiliation(s)
- You-Cheng Chang
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan; (Y.-C.C.); (C.-Y.S.); (C.-H.C.)
| | - Chen-Ying Su
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan; (Y.-C.C.); (C.-Y.S.); (C.-H.C.)
| | - Chia-Hua Chang
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan; (Y.-C.C.); (C.-Y.S.); (C.-H.C.)
| | - Hsu-Wei Fang
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan; (Y.-C.C.); (C.-Y.S.); (C.-H.C.)
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, No. 35, Keyan Road, Zhunan Town, Miaoli County 35053, Taiwan
- Correspondence: (H.-W.F.); (Y.W.)
| | - Yang Wei
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan; (Y.-C.C.); (C.-Y.S.); (C.-H.C.)
- Correspondence: (H.-W.F.); (Y.W.)
| |
Collapse
|
12
|
Giant papillary conjunctivitis: A review. Ocul Surf 2020; 18:396-402. [DOI: 10.1016/j.jtos.2020.03.007] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2020] [Accepted: 03/29/2020] [Indexed: 11/23/2022]
|
13
|
Ballard Z, Bazargan S, Jung D, Sathianathan S, Clemens A, Shir D, Al-Hashimi S, Ozcan A. Contact lens-based lysozyme detection in tear using a mobile sensor. LAB ON A CHIP 2020; 20:1493-1502. [PMID: 32227027 PMCID: PMC7189769 DOI: 10.1039/c9lc01039d] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
We report a method for sensing analytes in tear-fluid using commercial contact lenses (CLs) as sample collectors for subsequent analysis with a cost-effective and field-portable reader. In this study we quantify lysozyme, the most prevalent protein in tear fluid, non-specifically bound to CLs worn by human participants. Our mobile reader uses time-lapse imaging to capture an increasing fluorescent signal in a standard well-plate, the rate-of-change of which is used to indirectly infer lysozyme concentration through the use of a standard curve. We empirically determined the best-suited CL material for our sampling procedure and assay, and subsequently monitored the lysozyme levels of nine healthy human participants over a two-week period. Of these participants who were regular CL wearers (6 out of 9), we observed an increase in lysozyme levels from 6.89 ± 2.02 μg mL-1 to 10.72 ± 3.22 μg mL-1 (mean ± SD) when inducing an instance of digital eye-strain by asking them to play a game on their mobile-phones during the CL wear-duration. We also observed a lower mean lysozyme concentration (2.43 ± 1.66 μg mL-1) in a patient cohort with dry eye disease (DED) as compared to the average monitoring level of healthy (no DED) human participants (6.89 ± 2.02 μg mL-1). Taken together, this study demonstrates tear-fluid analysis with simple and non-invasive sampling steps along with a rapid, easy-to-use, and cost-effective measurement system, ultimately indicating physiological differences in human participants. We believe this method could be used in future tear-fluid studies, even supporting multiplexed detection of a panel of tear biomarkers toward improved diagnostics and prognostics as well as personalized mobile-health applications.
Collapse
Affiliation(s)
- Zachary Ballard
- Department of Electrical and Computer Engineering, University of California, Los Angeles, USA.
| | | | | | | | | | | | | | | |
Collapse
|
14
|
Absorption and Extraction of Inflammatory Mediators From Contact Lens Materials. Eye Contact Lens 2019; 45:340-345. [DOI: 10.1097/icl.0000000000000576] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
15
|
The influence of protein deposition on contact lens tear film stability. Colloids Surf B Biointerfaces 2019; 180:229-236. [DOI: 10.1016/j.colsurfb.2019.04.051] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Revised: 04/18/2019] [Accepted: 04/24/2019] [Indexed: 11/22/2022]
|
16
|
Efficacy of Contact Lens Care Solutions in Removing Cholesterol Deposits From Silicone Hydrogel Contact Lenses. Eye Contact Lens 2018; 45:105-111. [PMID: 30199424 DOI: 10.1097/icl.0000000000000547] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To determine the efficacy of multipurpose solutions (MPSs) on the removal of cholesterol deposits from silicone hydrogel (SH) contact lens materials using an in vitro model. MATERIALS AND METHODS Five SH lens materials: senofilcon A, comfilcon A, balafilcon A, lotrafilcon A, and lotrafilcon B were removed from the blister pack (n=4 for each lens type), incubated for 7 days at 37°C in an artificial tear solution containing C radiolabeled cholesterol. Thereafter, lenses were stored in a preserved saline solution control (Sensitive Eyes Saline Plus) or cleaned with 1 of the 5 MPSs incorporating different preservatives (POLYQUAD/ALDOX, polyquaternium-1/alexidine, polyquaternium-1/PHMB, and 2 based on PHMB alone) using a rub and rinse technique, according to the manufacturer's recommendations, and stored in the MPS for a minimum of 6 hr. Lenses were then extracted with 2:1 chloroform:methanol, analyzed in a beta counter, and μg/lens of cholesterol was determined. RESULTS Balafilcon A and senofilcon A lens materials showed the highest amounts of accumulated cholesterol (0.93±0.02 μg/lens; 0.95±0.01 μg/lens, respectively), whereas lotrafilcon A and lotrafilcon B deposited the lowest amounts (0.37±0.03 μg/lens; 0.47±0.12 μg/lens, respectively). For all lens materials, the MPS preserved with POLYQUAD/ALDOX removed more deposited cholesterol than any other test solution; however, the amount of removed cholesterol contamination from the individual contact lenses was only statistically significant for balafilcon A and senofilcon A (P=0.006 and P=0.042, respectively). Sensitive eyes and the other evaluated MPSs showed no significant effect on cholesterol removal (P>0.05). CONCLUSION Cholesterol-removal efficacy varies depending on the combination of lens material and solution. Only 1 MPS showed a statistically significant reduction of cholesterol deposit for only 2 of the 5 tested lens materials.
Collapse
|
17
|
Omali NB, Subbaraman LN, Heynen M, Ng A, Coles-Brennan C, Fadli Z, Jones L. Surface versus bulk activity of lysozyme deposited on hydrogel contact lens materials in vitro. Cont Lens Anterior Eye 2018; 41:329-334. [DOI: 10.1016/j.clae.2018.03.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2017] [Revised: 12/15/2017] [Accepted: 03/18/2018] [Indexed: 01/12/2023]
|
18
|
Shi DN, Song H, Ding T, Qiu WQ, Wang W. Evaluation of the safety and efficacy of therapeutic bandage contact lenses on post-cataract surgery patients. Int J Ophthalmol 2018; 11:230-234. [PMID: 29487811 DOI: 10.18240/ijo.2018.02.08] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2017] [Accepted: 01/05/2018] [Indexed: 01/27/2023] Open
Abstract
AIM To evaluate the safety of therapeutic bandage contact lens for post-cataract surgery patients and to illustrate its efficacy on post-operative comfort and tear-film stability. METHODS A total of 40 participants were recruited and randomly divided into two groups. Group one was instructed to wear bandage contact lenses for a week and use antibiotic eye drops for a month since the first day after surgery. Group two received sub-conjunctival injection of tobramycin and was asked to wear eye pads on the first day after surgery and then were instructed to use antibiotic eye drops as the first group did. Ocular surface disease index (OSDI) questionnaire, slit-lamp microscope examination of tear break-up time (TBUT), corneal fluorescein score (CFS), tear meniscus height (TMH) together with anterior segment optical coherence tomography (AS-OCT) and corneal topography were evaluated preoperatively and postoperatively. RESULTS The subjective feeling (P=0.004), TBUT (P<0.001) and TMH (P=0.02) post-surgery had improved in patients who used bandage contact lenses compared with those who did not at 1wk post-surgery. Until three month postoperatively, the comfort degree (P=0.004) and TMH (P=0.01) of group two were still worse than group one. Moreover, TBUT (P<0.001) and CFS (P=0.004) of the group with eye pads got worse than the results before, whereas the group with bandage contact lenses recovered to normal. None of these patients had infections or other complications. CONCLUSION Wearing therapeutic bandage contact lens after cataract surgery, compared with traditional eye-pads, is a safe method to improve tear-film stability and reduce post-operative discomfort without hindering corneal incision recovery.
Collapse
Affiliation(s)
- Dan-Na Shi
- Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China
| | - Hang Song
- Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China
| | - Tong Ding
- Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China
| | - Wei-Qiang Qiu
- Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China
| | - Wei Wang
- Department of Ophthalmology, Peking University Third Hospital, Beijing 100191, China
| |
Collapse
|
19
|
In Vitro Effect of Lysozyme on Albumin Deposition to Hydrogel Contact Lens Materials. Optom Vis Sci 2017; 94:1047-1051. [PMID: 29040199 DOI: 10.1097/opx.0000000000001137] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
SIGNIFICANCE Albumin deposition on contact lenses could be detrimental to contact lens (CL) wear because this may increase the risk of bacterial binding and reduce comfort. Lysozyme deposition on selected lens materials would reduce albumin deposition on lenses. PURPOSE This study aims to determine if lysozyme deposition on CLs could act as a barrier against subsequent albumin adsorption, using an in vitro model. METHODS Six hydrogel CL materials (etafilcon A, polymacon, nelfilcon A, omafilcon A, ocufilcon B, and nesofilcon A) were evaluated. Four CLs of each type were soaked in lysozyme solution for 16 hours at 37°C. Lysozyme-coated lenses were then placed in vials with 1.5 mL of artificial tear solution containing I-labeled albumin for 16 hours at 37°C with shaking. Four uncoated lenses of each type were used as controls. Lenses soaked in radiolabeled albumin were rinsed in a phosphate-buffered saline solution, and radioactive counts were measured directly on lenses using a gamma counter. Albumin uptake on lenses was measured using a calibration curve by plotting radioactive counts versus protein concentration. RESULTS Results are reported as mean ± SD. Lysozyme-coated etafilcon A lenses exhibited lower levels of deposited albumin than uncoated etafilcon A lenses (58 ± 12 vs. 84 ± 5 ng/lens; P < .05). There were no differences in albumin adsorption between control (uncoated) and lysozyme-coated polymacon (105 ± 10 vs. 110 ± 34 ng/lens), nelfilcon A (51 ± 7 vs. 42 ± 20 ng/lens), omafilcon A (90 ± 20 vs. 80 ± 38 ng/lens), ocufilcon B (87 ± 20 vs. 115 ± 50 ng/lens), and nesofilcon A (170 ± 29 vs. 161 ± 10 ng/lens) lens materials (P > .05). Uncoated nesofilcon A lenses deposited the highest amount of albumin when compared with other uncoated lenses (P < .05). CONCLUSIONS This study demonstrates that lysozyme deposited onto etafilcon A resists the deposition of albumin, which may potentially be beneficial to CL wearers.
Collapse
|
20
|
A Review of Techniques to Measure Protein Sorption to Soft Contact Lenses. Eye Contact Lens 2017; 43:276-286. [PMID: 28198731 DOI: 10.1097/icl.0000000000000366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To compare and critically evaluate a variety of techniques to measure the quantity and biological activity of protein sorption to contact lenses over short time periods. METHODS A literature review was undertaken investigating the major techniques to measure protein sorption to soft contact lens materials, with specific reference to measuring protein directly on lenses using in situ, ex situ, protein structural, and biological activity techniques. RESULTS The use of in situ techniques to measure protein quantity provides excellent sensitivity, but many are not directly applicable to contact lenses. Many ex situ techniques struggle to measure all sorbed proteins, and these measurements can have significant signal interference from the lens materials themselves. Techniques measuring the secondary and tertiary structures of sorbed proteins have exhibited only limited success. CONCLUSIONS There are a wide variety of techniques to measure both the amount of protein and the biological activity of protein sorbed to soft contact lens materials. To measure the mass of protein sorbed to soft contact lenses (not just thin films) over short time periods, the method of choice should be I radiolabeling. This technique is sensitive enough to measure small amounts of deposited protein, provided steps are taken to limit and measure any interaction of the iodine tracer with the materials. To measure the protein activity over short time periods, the method of choice should be to measure the biological function of sorbed proteins. This may require new methods or adaptations of existing ones.
Collapse
|
21
|
|
22
|
Guan A, Wang Y, Phillips KS, Li Z. A contact-lens-on-a-chip companion diagnostic tool for personalized medicine. LAB ON A CHIP 2016; 16:1152-1156. [PMID: 26923038 DOI: 10.1039/c6lc00034g] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
We present a novel, microfluidic platform that integrates human tears (1 μL) with commercial contact lens materials to provide personalized assessment of lens care solution performance. This device enabled the detection of significant differences in cleaning and disinfection outcomes between subjects and between biofilms vs. planktonic bacteria.
Collapse
Affiliation(s)
- Allan Guan
- Department of Biomedical Engineering, The George Washington University, 800 22nd Street NW, Washington, DC 20052, USA.
| | - Yi Wang
- Division of Biology, Chemistry and Materials Science, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA.
| | - K Scott Phillips
- Division of Biology, Chemistry and Materials Science, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA.
| | - Zhenyu Li
- Department of Biomedical Engineering, The George Washington University, 800 22nd Street NW, Washington, DC 20052, USA.
| |
Collapse
|
23
|
Omali NB, Subbaraman LN, Coles-Brennan C, Fadli Z, Jones LW. Biological and Clinical Implications of Lysozyme Deposition on Soft Contact Lenses. Optom Vis Sci 2015; 92:750-7. [PMID: 26002002 PMCID: PMC5638422 DOI: 10.1097/opx.0000000000000615] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2014] [Accepted: 02/17/2015] [Indexed: 12/28/2022] Open
Abstract
Within a few minutes of wear, contact lenses become rapidly coated with a variety of tear film components, including proteins, lipids, and mucins. Tears have a rich and complex composition, allowing a wide range of interactions and competitive processes, with the first event observed at the interface between a contact lens and tear fluid being protein adsorption. Protein adsorption on hydrogel contact lenses is a complex process involving a variety of factors relating to both the protein in question and the lens material. Among tear proteins, lysozyme is a major protein that has both antibacterial and anti-inflammatory functions. Contact lens materials that have high ionicity and high water content have an increased affinity to accumulate lysozyme during wear, when compared with other soft lens materials, notably silicone hydrogel lenses. This review provides an overview of tear film proteins, with a specific focus on lysozyme, and examines various factors that influence protein deposition on contact lenses. In addition, the impact of lysozyme deposition on various ocular physiological responses and bacterial adhesion to lenses and the interaction of lysozyme with other tear proteins are reviewed. This comprehensive review suggests that deposition of lysozyme on contact lens materials may provide a number of beneficial effects during contact lens wear.
Collapse
|
24
|
|
25
|
Xu J, Zhu W, Jiang L, Xu J, Zhang Y, Cui Y. Carbazole-grafted silicone hydrogel with a high refractive index for intraocular lens. RSC Adv 2015. [DOI: 10.1039/c5ra10614a] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
The refractive index (RI) is an important parameter for intraocular lens biomaterials.
Collapse
Affiliation(s)
- Jinku Xu
- Shandong Provincial Key Laboratory of Fine Chemical
- School of Chemistry and Pharmaceutical Engineering
- Qilu University of Technology
- Jinan
- China
| | - Weiyue Zhu
- Shandong Provincial Key Laboratory of Fine Chemical
- School of Chemistry and Pharmaceutical Engineering
- Qilu University of Technology
- Jinan
- China
| | - Lijuan Jiang
- Shandong Success Pharmaceutical Technology Co., Ltd
- Jinan
- China
| | - Jing Xu
- Shandong Provincial Key Laboratory of Fine Chemical
- School of Chemistry and Pharmaceutical Engineering
- Qilu University of Technology
- Jinan
- China
| | - Yongchun Zhang
- Shandong Provincial Key Laboratory of Fine Chemical
- School of Chemistry and Pharmaceutical Engineering
- Qilu University of Technology
- Jinan
- China
| | - Yuezhi Cui
- Shandong Provincial Key Laboratory of Fine Chemical
- School of Chemistry and Pharmaceutical Engineering
- Qilu University of Technology
- Jinan
- China
| |
Collapse
|
26
|
Hall B, Phan CM, Subbaraman L, Jones LW, Forrest J. Extraction versus In Situ Techniques for Measuring Surface-Adsorbed Lysozyme. Optom Vis Sci 2014; 91:1062-70. [DOI: 10.1097/opx.0000000000000354] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
27
|
|
28
|
|
29
|
Contact Lens In Vitro Wettability by Interferometry Measures of Drying Dynamics. Eye Contact Lens 2013; 39:365-75. [DOI: 10.1097/icl.0b013e318297394c] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
30
|
Ng A, Heynen M, Luensmann D, Subbaraman LN, Jones L. Impact of tear film components on the conformational state of lysozyme deposited on contact lenses. J Biomed Mater Res B Appl Biomater 2013; 101:1172-81. [PMID: 23564739 DOI: 10.1002/jbm.b.32927] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2012] [Revised: 12/06/2012] [Accepted: 01/30/2013] [Indexed: 11/07/2022]
Affiliation(s)
- Alan Ng
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| | - Miriam Heynen
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| | - Doerte Luensmann
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| | - Lakshman N. Subbaraman
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| | - Lyndon Jones
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| |
Collapse
|
31
|
Ng A, Heynen M, Luensmann D, Subbaraman LN, Jones L. Optimization of a fluorescence-based lysozyme activity assay for contact lens studies. Curr Eye Res 2013; 38:252-9. [PMID: 23373676 DOI: 10.3109/02713683.2012.757324] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE To optimize a fluorescence-based lysozyme activity assay to investigate the conformational state of lysozyme in solution and to determine the impact of extraction and evaporation procedures and the possible interference of contact lens materials on lysozyme activity. METHODS The fluorescence-based lysozyme activity assay, Enzchek (Molecular Probes Inc, Eugene, OR) which utilizes fluorescently quenched Micrococcus lysodeikticus, was compared to the gold standard, classical lysozyme turbidity assay, using four differently concentrated lysozyme samples (20, 10, 5.0 and 2.0 ng/µL). Furthermore, six differently concentrated lysozyme samples (2.0, 1.0, 0.5, 0.25, 0.125 and 0.01 µg/µL) were quantified using the fluorescence-based assay in the presence of extraction solvents consisting of 0.2% and 0.02% trifluroacetic acid/acetonitrile and following evaporation procedures. RESULTS A standard curve was generated by the fluorescence-based assay ranging from 2 to 150 ng. The total active lysozyme quantified in the four lysozyme samples was not significantly different between the two assays (p > 0.05) and the concordance correlation coefficient was determined to be 0.995. However an average discrepancy between the two assays was found to be 0.474 ng, with the turbidity assay typically reporting higher active lysozyme measurements. The sensitivity of the fluorescence-based assay was higher than the classical turbidity assay when quantifying 20 ng or less active lysozyme. Following the extraction and evaporation procedures and the addition of lens extracts, the total active lysozyme recovered was 95% or greater. CONCLUSIONS In comparison to the classical turbidity assay, the fluorescence-based assay is a very sensitive method, making it a favorable technique, particularly when studying contact lens materials that deposit relatively low levels of lysozyme.
Collapse
Affiliation(s)
- Alan Ng
- Centre for Contact Lens Research, School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
| | | | | | | | | |
Collapse
|
32
|
Bengani LC, Chauhan A. Extended delivery of an anionic drug by contact lens loaded with a cationic surfactant. Biomaterials 2013; 34:2814-21. [PMID: 23337326 DOI: 10.1016/j.biomaterials.2012.12.027] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2012] [Accepted: 12/22/2012] [Indexed: 11/29/2022]
Abstract
Drug eluding contact lenses can be very effective vehicles for ophthalmic drug delivery, but are incapable of releasing drug for more than a few hours. We propose to optimize the interactions of the polymer matrix of the contact lens with the hydrophobic tails of ionic surfactants to adsorb the surfactant molecules on the polymer with high packing and thus create a high surface charge. Ionic drugs can then adsorb on the charged surfactant coated surfaces with high affinity to reduce the transport rates, leading to extended release. Specifically, we show control release of an anionic drug dexamethasone 21-disodium phosphate from poly-hydroxyethyl methacrylate (p-HEMA) contact lenses by utilizing cationic surfactant (cetalkonium chloride). The partition coefficient of the drug increase exponentially with surfactant loading in the gel in at least qualitative agreement with the Debye-Hückel theory. The drug adsorbs on the surfactant covered polymer, and can also diffuse along the surface with diffusivity lower than that for the free drug, leading to a reduction in the effective diffusivity, which is the weighted combination of the free and surface diffusivities. The addition of surfactant did not impact transparency of lenses, and had additional benefits of increase in wettability and significant reduction in protein absorption. With a surfactant loading of about 10%, the drug release duration was increased from about 2 h to 50 h in 1-day ACUVUE(®) contact lenses, proving the viability of using surfactant for increasing drug release durations.
Collapse
|
33
|
|
34
|
|
35
|
Lysozyme transport in p-HEMA hydrogel contact lenses. J Colloid Interface Sci 2012; 386:441-50. [DOI: 10.1016/j.jcis.2012.07.018] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2012] [Revised: 07/06/2012] [Accepted: 07/07/2012] [Indexed: 11/23/2022]
|
36
|
|
37
|
Hall B, Jones L, Forrest JA. Measuring the kinetics and activity of adsorbed proteins:In vitrolysozyme deposited onto hydrogel contact lenses over short time periods. J Biomed Mater Res A 2012; 101:755-64. [DOI: 10.1002/jbm.a.34357] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2011] [Revised: 06/05/2012] [Accepted: 06/20/2012] [Indexed: 11/11/2022]
|
38
|
|
39
|
|
40
|
Weeks A, Boone A, Luensmann D, Jones L, Sheardown H. The effects of hyaluronic acid incorporated as a wetting agent on lysozyme denaturation in model contact lens materials. J Biomater Appl 2012; 28:323-33. [PMID: 22561981 DOI: 10.1177/0885328212446936] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Conventional and silicone hydrogels as models for contact lenses were prepared to determine the effect of the presence of hyaluronic acid on lysozyme sorption and denaturation. Hyaluronic acid was loaded into poly(2-hydroxyethyl methacrylate) and poly(2-hydroxyethyl methacrylate)/TRIS--methacryloxypropyltris (trimethylsiloxy silane) hydrogels, which served as models for conventional and silicone hydrogel contact lens materials. The hyaluronic acid was cross-linked using 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide in the presence of dendrimers. Active lysozyme was quantified using a Micrococcus lysodeikticus assay while total lysozyme was determined using 125-I radiolabeled protein. To examine the location of hyaluronic acid in the gels, 6-aminofluorescein labeled hyaluronic acid was incorporated into the gels using 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide chemistry and the gels were examined using confocal laser scanning microscopy. Hyaluronic acid incorporation significantly reduced lysozyme sorption in poly(2-hydroxyethyl methacrylate) (p < 0.00001) and poly(2-hydroxyethyl methacrylate)/TRIS--methacryloxypropyltris (trimethylsiloxy silane) (p < 0.001) hydrogels, with the modified materials sorbing only 20% and 16% that of the control, respectively. More importantly, hyaluronic acid also decreased lysozyme denaturation in poly(2-hydroxyethyl methacrylate) (p < 0.005) and poly(2-hydroxyethyl methacrylate)/TRIS--methacryloxypropyltris (trimethylsiloxy silane) (p < 0.02) hydrogels. The confocal laser scanning microscopy results showed that the hyaluronic acid distribution was dependent on both the material type and the molecular weight of hyaluronic acid. This study demonstrates that hyaluronic acid incorporated as a wetting agent has the potential to reduce lysozyme sorption and denaturation in contact lens applications. The distribution of hyaluronic acid within hydrogels appears to affect denaturation, with more surface mobile, lower molecular weight hyaluronic acid being more effective in preventing denaturation.
Collapse
Affiliation(s)
- Andrea Weeks
- School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada
| | | | | | | | | |
Collapse
|
41
|
Weeks A, Subbaraman LN, Jones L, Sheardown H. The Competing Effects of Hyaluronic and Methacrylic Acid in Model Contact Lenses. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2012; 23:1021-38. [DOI: 10.1163/092050611x569060] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Affiliation(s)
- Andrea Weeks
- a School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada L8S 4L7
| | | | - Lyndon Jones
- c School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada L8S 4L7; Department of Chemical Engineering, McMaster University, Hamilton, ON, Canada L8S 4L7; Centre for Contact Lens Research, University of Waterloo, Waterloo, ON, Canada
| | - Heather Sheardown
- d School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada L8S 4L7; Department of Chemical Engineering, McMaster University, Hamilton, ON, Canada L8S 4L7; Centre for Contact Lens Research, University of Waterloo, Waterloo, ON, Canada.
| |
Collapse
|
42
|
Chow LM, Subbaraman LN, Sheardown H, Jones L. Kinetics of in Vitro Lactoferrin Deposition on Silicone Hydrogel and FDA Group II and Group IV Hydrogel Contact Lens Materials. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2012; 20:71-82. [PMID: 19105901 DOI: 10.1163/156856208x393509] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Affiliation(s)
- Lisa M. Chow
- a Centre for Contact Lens Research, School of Optometry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, Canada N2L 3G1
| | - Lakshman N. Subbaraman
- b Centre for Contact Lens Research, School of Optometry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, Canada N2L 3G1
| | - Heather Sheardown
- c Department of Chemical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario, Canada L8S 4L8
| | - Lyndon Jones
- d Centre for Contact Lens Research, School of Optometry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, Canada N2L 3G1
| |
Collapse
|
43
|
Subbaraman LN, Jones L. Kinetics of Lysozyme Activity Recovered from Conventional and Silicone Hydrogel Contact Lens Materials. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2012; 21:343-58. [DOI: 10.1163/156856209x415873] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Affiliation(s)
- Lakshman N. Subbaraman
- a Centre for Contact Lens Research, School of Optometry, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Lyndon Jones
- b Centre for Contact Lens Research, School of Optometry, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| |
Collapse
|
44
|
|
45
|
Protein deposition on contact lenses: The past, the present, and the future. Cont Lens Anterior Eye 2012; 35:53-64. [DOI: 10.1016/j.clae.2011.12.005] [Citation(s) in RCA: 119] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2010] [Revised: 12/18/2011] [Accepted: 12/24/2011] [Indexed: 11/19/2022]
|
46
|
Clinical Benefits of a New Multipurpose Disinfecting Solution in Silicone Hydrogel and Soft Contact Lens Users. Eye Contact Lens 2012; 38:93-101. [DOI: 10.1097/icl.0b013e318243c1a3] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
47
|
Preservation of human tear protein structure and function by a novel contact lens multipurpose solution containing protein-stabilizing agents. Eye Contact Lens 2012; 38:36-42. [PMID: 22146703 DOI: 10.1097/icl.0b013e31823fdb2a] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES Tear film proteins have antimicrobial and other functions that may be lost after denaturation during contact lens wear. A new multipurpose solution has recently become available (Biotrue, Bausch + Lomb Inc., Rochester, NY), which contains protein-stabilizing agents including hyaluronic acid, poloxamine, and sulfobetaine 10, the latter used previously as a laboratory tool to renature proteins. We examine whether this new multipurpose solution formulation can prevent the denaturation of human lactoferrin and lysozyme at physiologic levels in response to a powerful denaturing challenge. METHODS Human lactoferrin and lysozyme were treated with sodium dodecyl sulfate (SDS) either with or without an investigational version of the new multipurpose solution (without its two disinfectant agents) (investigational multipurpose solution [iMPS]). The structure was assessed by native-polyacrylamide gel electrophoresis (PAGE), differential scanning calorimetry (DSC), and fluorometry; additionally, antimicrobial activity against Pseudomonas aeruginosa and Staphylococcus aureus was measured. RESULTS The iMPS prevented an SDS-induced shift in the native-PAGE banding position of lactoferrin. The SDS treatment substantially altered the lactoferrin DSC and fluorescence spectra, indicating that the protein had denatured. This change did not occur in the presence of iMPS. Lactoferrin and lysozyme showed antibacterial and bacteriolytic activity, which was abolished after SDS treatment; this loss of activity did not occur for proteins treated with iMPS. CONCLUSIONS These data clearly show that the iMPS prevents the denaturation of physiologic levels of human lactoferrin and lysozyme by the strongly denaturing surfactant SDS and that stabilized proteins retain their function. We conclude that this solution has the capacity to stabilize the structure and function of tear proteins.
Collapse
|
48
|
Omali NB, Zhao Z, Zhong L, Raftery MJ, Zhu H, Ozkan J, Willcox M. Quantification of protein deposits on silicone hydrogel materials using stable-isotopic labeling and multiple reaction monitoring. BIOFOULING 2012; 28:697-709. [PMID: 22784025 DOI: 10.1080/08927014.2012.702763] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
This study was designed to use multiple reaction monitoring (MRM) for accurate quantification of contact lens protein deposits. Worn lenses used with a multipurpose disinfecting solution were collected after wear. Individual contact lenses were extracted and then digested with trypsin. MRM in conjunction with stable-isotope-labeled peptide standards was used for protein quantification. The results show that lysozyme was the major protein detected from both lens types. The amount of protein extracted from contact lenses was affected by the lens material. Except for keratin-1 (0.83 ± 0.61 vs 0.77 ± 0.20, p = 0.81) or proline rich protein-4 (0.11 ± 0.04 vs 0.15 ± 0.12, p = 0.97), the amounts of lysozyme, lactoferrin, or lipocalin-1 extracted from balafilcon A lenses (12.9 ± 9.01, 0.84 ± 0.50 or 2.06 ± 1.6, respectively) were significantly higher than that extracted from senofilcon A lenses (0.88 ± 0.13, 0.50 ± 0.10 or 0.27 ± 0.23, respectively) (p < 0.05). The amount of protein extracted from contact lenses was dependent on both the individual wearer and the contact lens material. This may have implications for the development of clinical responses during lens wear for different people and with different types of contact lenses. The use of MRM-MS is a powerful analytical tool for the quantification of specific proteins from single contact lenses after wear.
Collapse
|
49
|
|
50
|
|