1
|
Lanjwani MF, Tuzen M, Khuhawar MY, Afshar Mogaddam MR, Farajzadeh MA. Deep Eutectic Solvents for Extraction and Preconcentration of Organic and Inorganic Species in Water and Food Samples: A Review. Crit Rev Anal Chem 2024; 54:1290-1303. [PMID: 35980662 DOI: 10.1080/10408347.2022.2111655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
Abstract
Deep eutectic solvents (DESs) have been developed as green solvents and these are capable as alternatives to conventional solvents used for the extraction of organic and inorganic species from food and water samples. The continuous generation of contaminated waste and increasing concern for the human health and environment have compelled the scientific community to investigate more ecological schemes. In this concern, the use of DESs have developed in one of the chief approach in the field of chemistry. These solvents have appeared as a capable substitute to conventional hazardous solvents and ionic liquids. The DESs has distinctive properties, easy preparation and components availability. It is not only used in scienctific fields but also used in quotidian life. There are many advantages of DESs in analytical chemistry, they are largely used for extraction and determination of inorganic and organic compounds from different samples. In previous a few years, several advanced researches have been focused on the separation and preconcentration of low level of pollutants using DESs as the extractants. This review summarizes the use of DESs in the separation and preconcentration of organic and inorganic species from water and food samples using various microextraction processes.
Collapse
Affiliation(s)
- Muhammad Farooque Lanjwani
- Faculty of Science and Arts, Chemistry Department, Tokat Gaziosmanpasa University, Tokat, Turkey
- Dr M. A. Kazi Institute of Chemistry, University of Sindh, Jamshoro, Sindh, Pakistan
| | - Mustafa Tuzen
- Faculty of Science and Arts, Chemistry Department, Tokat Gaziosmanpasa University, Tokat, Turkey
- King Fahd University of Petroleum and Minerals, Research Institute, Center for Environment and Marine Studies, Dhahran, Saudi Arabia
| | - Muhammad Yar Khuhawar
- Institute of Advanced Research Studies in Chemical Sciences, University of Sindh, Jamshoro, Sindh, Pakistan
| | - Mohammad Reza Afshar Mogaddam
- Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mir Ali Farajzadeh
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| |
Collapse
|
2
|
Luján CE, Lemos AA, Oviedo MN, Llaver M, Wuilloud RG. Deep eutectic solvents as a green alternative for trace element analysis in food and beverage samples: Recent advances and challenges. Talanta 2024; 269:125451. [PMID: 38048680 DOI: 10.1016/j.talanta.2023.125451] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 11/17/2023] [Accepted: 11/20/2023] [Indexed: 12/06/2023]
Abstract
Metals and metalloids have different effects on human health even at trace levels. Some of them are essential for living organisms while others can be toxic. Therefore, the determination of trace elements in food and beverage is highly important to understand their impact in human health. A new generation of solvents named deep eutectic solvents (DES) has emerged as a green alternative for trace element analysis, owing to their low toxicity, biodegradability, and high extraction capacity. In recent years, the application of DES in extraction techniques for trace element analysis in food and beverage samples has increased significantly. This review summarizes recent advances and challenges on the application of DES to develop microextraction techniques useful for the analysis of samples with complex matrices. The importance of the use of biodegradable substances instead of classic organic solvents, which are toxic, volatile, and flammable in methods for elemental analysis with a positive environmental impact is also highlighted. Finally, conclusions and future challenges arising from the use of DES in microextraction techniques are discussed.
Collapse
Affiliation(s)
- Cecilia E Luján
- Laboratorio de Química Analítica para Investigación y Desarrollo (QUIANID), Facultad de Ciencias Exactas y Naturales, Universidad Nacional de Cuyo/Instituto Interdisciplinario de Ciencias Básicas (ICB), CONICET UNCUYO, Padre J. Contreras 1300, (5500) Mendoza, Argentina
| | - Aldana A Lemos
- Laboratorio de Química Analítica para Investigación y Desarrollo (QUIANID), Facultad de Ciencias Exactas y Naturales, Universidad Nacional de Cuyo/Instituto Interdisciplinario de Ciencias Básicas (ICB), CONICET UNCUYO, Padre J. Contreras 1300, (5500) Mendoza, Argentina
| | - María N Oviedo
- Laboratorio de Química Analítica para Investigación y Desarrollo (QUIANID), Facultad de Ciencias Exactas y Naturales, Universidad Nacional de Cuyo/Instituto Interdisciplinario de Ciencias Básicas (ICB), CONICET UNCUYO, Padre J. Contreras 1300, (5500) Mendoza, Argentina
| | - Mauricio Llaver
- Laboratorio de Química Analítica para Investigación y Desarrollo (QUIANID), Facultad de Ciencias Exactas y Naturales, Universidad Nacional de Cuyo/Instituto Interdisciplinario de Ciencias Básicas (ICB), CONICET UNCUYO, Padre J. Contreras 1300, (5500) Mendoza, Argentina
| | - Rodolfo G Wuilloud
- Laboratorio de Química Analítica para Investigación y Desarrollo (QUIANID), Facultad de Ciencias Exactas y Naturales, Universidad Nacional de Cuyo/Instituto Interdisciplinario de Ciencias Básicas (ICB), CONICET UNCUYO, Padre J. Contreras 1300, (5500) Mendoza, Argentina.
| |
Collapse
|
3
|
Chormey DS, Zaman BT, Kustanto TB, Erarpat Bodur S, Bodur S, Er EÖ, Bakırdere S. Deep eutectic solvents for the determination of endocrine disrupting chemicals. Talanta 2024; 268:125340. [PMID: 37948953 DOI: 10.1016/j.talanta.2023.125340] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2023] [Revised: 10/18/2023] [Accepted: 10/23/2023] [Indexed: 11/12/2023]
Abstract
The harmful effects of endocrine disrupting chemicals (EDCs) to humans and other organisms in the environment have been well established over the years, and more studies are ongoing to classify other chemicals that have the potential to alter or disrupt the regular function of the endocrine system. In addition to toxicological studies, analytical detection systems are progressively being improved to facilitate accurate determination of EDCs in biological, environmental and food samples. Recent microextraction methods have focused on the use of green chemicals that are safe for analytical applications, and present very low or no toxicity upon disposal. Deep eutectic solvents (DESs) have emerged as one of the viable alternatives to the conventional hazardous solvents, and their unique properties make them very useful in different applications. Notably, the use of renewable sources to prepare DESs leads to highly biodegradable products that mitigate negative ecological impacts. This review presents an overview of both organic and inorganic EDCs and their ramifications on human health. It also presents the fundamental principles of liquid phase and solid phase microextraction methods, and gives a comprehensive account of the use of DESs for the determination of EDCs in various samples.
Collapse
Affiliation(s)
- Dotse Selali Chormey
- Yıldız Technical University, Department of Chemistry, 34220, İstanbul, Turkiye; Neutec Pharmaceutical, Yıldız Technical University Teknopark, 34220, İstanbul, Turkiye.
| | - Buse Tuğba Zaman
- Yıldız Technical University, Department of Chemistry, 34220, İstanbul, Turkiye
| | - Tülay Borahan Kustanto
- Yıldız Technical University, Department of Chemistry, 34220, İstanbul, Turkiye; Neutec Pharmaceutical, Yıldız Technical University Teknopark, 34220, İstanbul, Turkiye
| | - Sezin Erarpat Bodur
- Yıldız Technical University, Department of Chemistry, 34220, İstanbul, Turkiye
| | - Süleyman Bodur
- Yıldız Technical University, Department of Chemistry, 34220, İstanbul, Turkiye; İstinye University, Faculty of Pharmacy, Department of Analytical Chemistry, 34010, İstanbul, Turkiye; İstinye University, Scientific and Technological Research Application and Research Center, 34010, İstanbul, Turkiye
| | - Elif Özturk Er
- İstanbul Technical University, Department of Chemical Engineering, 34469, İstanbul, Turkiye
| | - Sezgin Bakırdere
- Yıldız Technical University, Department of Chemistry, 34220, İstanbul, Turkiye; Turkish Academy of Sciences (TÜBA), Vedat Dalokay Street, No: 112, 06670, Çankaya, 06670, Ankara, Turkiye.
| |
Collapse
|
4
|
Andruch V, Kalyniukova A, Płotka-Wasylka J, Jatkowska N, Snigur D, Zaruba S, Płatkiewicz J, Zgoła-Grześkowiak A, Werner J. Application of deep eutectic solvents in sample preparation for analysis (update 2017–2022). Part A: Liquid phase microextraction. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
5
|
Sensitive optical thin film sensor based on incorporation of 2-(2′-hydroxynaphthylazo)-benzothiazole in a sol–gel matrix for detection of manganese(II) in environmental samples. Anal Biochem 2022; 651:114720. [DOI: 10.1016/j.ab.2022.114720] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Revised: 04/26/2022] [Accepted: 05/03/2022] [Indexed: 12/23/2022]
|
6
|
Gösterişli TU, Cesur B, Tezgit E, Bakırdere EG, Keyf S, Bakırdere S. Determination of Palladium in Precious Metal Waste by Sieve Conducted Two Syringes Pressurized Liquid Phase Microextraction (SCTS-PLPME) and Slotted Quartz Tube Flame Atomic Absorption Spectrometry (SQT-FAAS). ANAL LETT 2021. [DOI: 10.1080/00032719.2021.1920607] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Affiliation(s)
| | - Buket Cesur
- Department of Chemistry, Yıldız Technical University, İstanbul, Turkey
| | - Ezgi Tezgit
- Department of Chemistry, Yıldız Technical University, İstanbul, Turkey
| | | | - Seyfullah Keyf
- Department of Chemical Engineering, Yıldız Technical University, İstanbul, Turkey
| | - Sezgin Bakırdere
- Department of Chemistry, Yıldız Technical University, İstanbul, Turkey
- Turkish Academy of Sciences, Çankaya, Ankara
| |
Collapse
|
7
|
Tavakoli M, Jamali MR, Nezhadali A. Ultrasound-Assisted Dispersive Liquid–Liquid Microextraction (DLLME) Based on Solidification of Floating Organic Drop Using a Deep Eutectic Solvent for Simultaneous Preconcentration and Determination of Nickel and Cobalt in Food and Water Samples. ANAL LETT 2021. [DOI: 10.1080/00032719.2021.1897990] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- Maedeh Tavakoli
- Department of Chemistry, Payame Noor University, Tehran, Iran
| | | | | |
Collapse
|