• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4670600)   Today's Articles (2339)
For: Compagnone D, Massoud R, Di Ilio C, Federici G. Potentiometric Determination of Glutathione and Glutathione Transferase Activity. ANAL LETT 1991. [DOI: 10.1080/00032719108054369] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Number Cited by Other Article(s)
1
Adenuga AA, Wright ME, Atkinson DB. Evaluation of the reactivity of exhaust from various biodiesel blends as a measure of possible oxidative effects: A concern for human exposure. CHEMOSPHERE 2016;147:396-403. [PMID: 26774305 DOI: 10.1016/j.chemosphere.2015.12.074] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2015] [Revised: 12/18/2015] [Accepted: 12/21/2015] [Indexed: 06/05/2023]
2
Anik Ü, Çubukçu M, Ertaş FN. An effective electrochemical biosensing platform for the detection of reduced glutathione. ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY 2015;44:971-7. [DOI: 10.3109/21691401.2015.1008504] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
3
Narang J, Chauhan N, Jain P, Pundir C. Silver nanoparticles/multiwalled carbon nanotube/polyaniline film for amperometric glutathione biosensor. Int J Biol Macromol 2012;50:672-8. [DOI: 10.1016/j.ijbiomac.2012.01.023] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2011] [Accepted: 01/15/2012] [Indexed: 10/14/2022]
4
Uehara N, Ookubo K, Shimizu T. Colorimetric assay of glutathione based on the spontaneous disassembly of aggregated gold nanocomposites conjugated with water-soluble polymer. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2010;26:6818-6825. [PMID: 20373784 DOI: 10.1021/la100460w] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
5
Hou Y, Ndamanisha JC, Guo LP, Peng XJ, Bai J. Synthesis of ordered mesoporous carbon/cobalt oxide nanocomposite for determination of glutathione. Electrochim Acta 2009. [DOI: 10.1016/j.electacta.2009.05.091] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
6
Sehlotho N, Griveau S, Ruillé N, Boujtita M, Nyokong T, Bedioui F. Electro-catalyzed oxidation of reduced glutathione and 2-mercaptoethanol by cobalt phthalocyanine-containing screen printed graphite electrodes. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2008. [DOI: 10.1016/j.msec.2007.10.054] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
7
Yang P, Chen Y, Zhu Q, Wang F, Wang L, Li Y. Sensitive chemiluminescence method for the determination of glutathione, l-cysteine and 6-mercaptopurine. Mikrochim Acta 2008. [DOI: 10.1007/s00604-008-0006-5] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
8
de Cássia Silva Luz R, Damos FS, Gandra PG, de Macedo DV, Tanaka AA, Kubota LT. Electrocatalytic determination of reduced glutathione in human erythrocytes. Anal Bioanal Chem 2007;387:1891-7. [PMID: 17200855 DOI: 10.1007/s00216-006-1053-6] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2006] [Revised: 11/17/2006] [Accepted: 11/28/2006] [Indexed: 10/23/2022]
9
Pereira-Rodrigues N, Cofré R, Zagal JH, Bedioui F. Electrocatalytic activity of cobalt phthalocyanine CoPc adsorbed on a graphite electrode for the oxidation of reduced l-glutathione (GSH) and the reduction of its disulfide (GSSG) at physiological pH. Bioelectrochemistry 2007;70:147-54. [PMID: 16723282 DOI: 10.1016/j.bioelechem.2006.03.025] [Citation(s) in RCA: 72] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2005] [Indexed: 11/17/2022]
10
Rover L, Kubota LT, Höehr NF. Development of an amperometric biosensor based on glutathione peroxidase immobilized in a carbodiimide matrix for the analysis of reduced glutathione from serum. Clin Chim Acta 2001;308:55-67. [PMID: 11412817 DOI: 10.1016/s0009-8981(01)00394-1] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
11
Compagnone D, Federici G, Scarciglia L, Palleschi G. Flow-Through Analysis of Glutathione in Human Erythrocytes with an Amperometric Biosensor. ANAL LETT 1994. [DOI: 10.1080/00032719408006343] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
PrevPage 1 of 1 1Next
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA