1
|
Sola-Gazagnes A, Pecquet C, Berré S, Achenbach P, Pierson LA, Virmoux-Buisson I, M'Bemba J, Elgrably F, Moguelet P, Boitard C, Caillat-Zucman S, Laanani M, Coste J, Larger E, Mallone R. Insulin allergy: a diagnostic and therapeutic strategy based on a retrospective cohort and a case-control study. Diabetologia 2022; 65:1278-1290. [PMID: 35505238 DOI: 10.1007/s00125-022-05710-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Accepted: 03/30/2022] [Indexed: 11/24/2022]
Abstract
AIMS/HYPOTHESIS Insulin allergy is a rare but significant clinical challenge. We aimed to develop a management workflow by (1) validating clinical criteria to guide diagnosis, based on a retrospective cohort, and (2) assessing the diagnostic performance of confirmatory tests, based on a case-control study. METHODS In the retrospective cohort, patients with suspected insulin allergy were classified into three likelihood categories according to the presence of all (likely insulin allergy; 26/52, 50%), some (possible insulin allergy; 9/52, 17%) or none (unlikely insulin allergy; 17/52, 33%) of four clinical criteria: (1) recurrent local or systemic immediate or delayed hypersensitivity reactions; (2) reactions elicited by each injection; (3) reactions centred on the injection sites; and (4) reactions observed by the investigator (i.e. in response to an insulin challenge test). All underwent intradermal reaction (IDR) tests. A subsequent case-control study assessed the diagnostic performance of IDR, skin prick and serum anti-insulin IgE tests in ten clinically diagnosed insulin allergy patients, 24 insulin-treated non-allergic patients and 21 insulin-naive patients. RESULTS In the retrospective cohort, an IDR test validated the clinical diagnosis in 24/26 (92%), 3/9 (33%) and 0/14 (0%) likely, possible and unlikely insulin allergy patients, respectively. In the case-control study, an IDR test was 80% sensitive and 100% specific and identified the index insulin(s). The skin prick and IgE tests had a marginal diagnostic value. Patients with IDR-confirmed insulin allergy were treated using a stepwise strategy. CONCLUSIONS/INTERPRETATION Subject to validation, clinical likelihood criteria can effectively guide diabetologists towards an insulin allergy diagnosis before undertaking allergology tests. An IDR test shows the best diagnostic performance. A progressive management strategy can subsequently be implemented. Continuous subcutaneous insulin infusion is ultimately required in most patients. CLINICALTRIALS gov: NCT01407640.
Collapse
Affiliation(s)
- Agnès Sola-Gazagnes
- Assistance Publique-Hôpitaux de Paris, Hôpitaux Universitaires de Paris Centre-Université Paris Cité, Cochin Hospital, Service de Diabétologie et Immunologie Clinique, Paris, France.
| | - Catherine Pecquet
- Assistance Publique-Hôpitaux de Paris, Hôpital Tenon, Service d'Allergologie Dermatologie, Paris, France
| | - Stefano Berré
- Université Paris Cité, CNRS, Inserm, Institut Cochin, Paris, France
| | - Peter Achenbach
- Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Diabetes Research, Munich-Neuherberg, Germany
- Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Forschergruppe Diabetes, Munich, Germany
| | - Laure-Anne Pierson
- Assistance Publique-Hôpitaux de Paris, Hôtel-Dieu, Service de Pharmacie, Pharmacologie, Toxicologie, Paris, France
| | - Isabelle Virmoux-Buisson
- Assistance Publique-Hôpitaux de Paris, Hôpitaux Universitaires de Paris Centre-Université Paris Cité, Cochin Hospital, Service de Diabétologie et Immunologie Clinique, Paris, France
| | - Jocelyne M'Bemba
- Assistance Publique-Hôpitaux de Paris, Hôpitaux Universitaires de Paris Centre-Université Paris Cité, Cochin Hospital, Service de Diabétologie et Immunologie Clinique, Paris, France
| | - Fabienne Elgrably
- Assistance Publique-Hôpitaux de Paris, Hôpitaux Universitaires de Paris Centre-Université Paris Cité, Cochin Hospital, Service de Diabétologie et Immunologie Clinique, Paris, France
| | - Philippe Moguelet
- Assistance Publique-Hôpitaux de Paris, Hôpital Tenon, Service d'Anatomo-Pathologie, Sorbonne Université, Faculté de Médecine, Paris, France
| | - Christian Boitard
- Assistance Publique-Hôpitaux de Paris, Hôpitaux Universitaires de Paris Centre-Université Paris Cité, Cochin Hospital, Service de Diabétologie et Immunologie Clinique, Paris, France
- Université Paris Cité, CNRS, Inserm, Institut Cochin, Paris, France
| | - Sophie Caillat-Zucman
- Assistance Publique-Hôpitaux de Paris, Hôpital Saint-Louis, Laboratoire d'Immunologie, Paris, France
- Université Paris Cité, Inserm UMR976, Institut de Recherche Saint-Louis, Paris, France
| | - Moussa Laanani
- Université Paris Cité, Assistance Publique-Hôpitaux de Paris, Cochin Hospital, Biostatistics and Epidemiology Unit, Paris, France
| | - Joel Coste
- Université Paris Cité, Assistance Publique-Hôpitaux de Paris, Cochin Hospital, Biostatistics and Epidemiology Unit, Paris, France
| | - Etienne Larger
- Assistance Publique-Hôpitaux de Paris, Hôpitaux Universitaires de Paris Centre-Université Paris Cité, Cochin Hospital, Service de Diabétologie et Immunologie Clinique, Paris, France
- Université Paris Cité, CNRS, Inserm, Institut Cochin, Paris, France
| | - Roberto Mallone
- Assistance Publique-Hôpitaux de Paris, Hôpitaux Universitaires de Paris Centre-Université Paris Cité, Cochin Hospital, Service de Diabétologie et Immunologie Clinique, Paris, France
- Université Paris Cité, CNRS, Inserm, Institut Cochin, Paris, France
| |
Collapse
|
2
|
Abstract
The control of blood glucose levels in diabetes involving devices are critically reviewed, and the role of blood-contacting biomaterial components analyzed. These include mechanical insulin-delivery systems of the closed-loop type that require an electronic glucose sensor and feedback, and open-loop systems that deliver insulin without a sensor and feedback. Whole pancreatic and islet transplantations, islet encapsulation, and the potential role of polymeric sustained drug delivery systems are discussed. The medical and social impacts of diabetes mellitus are of prime public health concern and of even greater magnitude than those of heart disease in the United States. While future advances in device design, miniaturization, and biometrials technology will significantly add to the arsenal of therapeutic alternatives, devices capable of controlling blood glucose levels ought to be viewed as mere interim phases rather than as final goals of the problem.
Collapse
Affiliation(s)
- S.D. Bruck
- Biomaterials and Pharmacological Systems Stephen D. Bruck Associates, Inc. Bethesda, Maryland 20014, USA
| |
Collapse
|
3
|
Fineberg SE, Kawabata TT, Finco-Kent D, Fountaine RJ, Finch GL, Krasner AS. Immunological responses to exogenous insulin. Endocr Rev 2007; 28:625-52. [PMID: 17785428 DOI: 10.1210/er.2007-0002] [Citation(s) in RCA: 119] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Regardless of purity and origin, therapeutic insulins continue to be immunogenic in humans. However, severe immunological complications occur rarely, and less severe events affect a small minority of patients. Insulin autoantibodies (IAAs) may be detectable in insulin-naive individuals who have a high likelihood of developing type 1 diabetes or in patients who have had viral disorders, have been treated with various drugs, or have autoimmune disorders or paraneoplastic syndromes. This suggests that under certain circumstances, immune tolerance to insulin can be overcome. Factors that can lead to more or less susceptibility to humoral responses to exogenous insulin include the recipient's immune response genes, age, the presence of sufficient circulating autologous insulin, and the site of insulin delivery. Little proof exists, however, that the development of insulin antibodies (IAs) to exogenous insulin therapy affects integrated glucose control, insulin dose requirements, and incidence of hypoglycemia, or contributes to beta-cell failure or to long-term complications of diabetes. Studies in which pregnant women with diabetes were monitored for glycemic control argue against a connection between IAs and fetal risk. Although studies have shown increased levels of immune complexes in patients with diabetic microangiopathic complications, these immune complexes often do not contain insulin or IAs, and insulin administration does not contribute to their formation. The majority of studies have shown no relationship between IAs and diabetic angiopathic complications, including nephropathy, retinopathy, and neuropathy. With the advent of novel insulin formulations and delivery systems, such as insulin pumps and inhaled insulin, examination of these issues is increasingly relevant.
Collapse
Affiliation(s)
- S Edwin Fineberg
- Indiana University School of Medicine, Indianapolis, Indiana 46202, USA.
| | | | | | | | | | | |
Collapse
|