1
|
Kok HP, Crezee J. Fast Adaptive Temperature-Based Re-Optimization Strategies for On-Line Hot Spot Suppression during Locoregional Hyperthermia. Cancers (Basel) 2021; 14:cancers14010133. [PMID: 35008300 PMCID: PMC8749938 DOI: 10.3390/cancers14010133] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 12/21/2021] [Accepted: 12/23/2021] [Indexed: 11/16/2022] Open
Abstract
Simple Summary When treatment limiting hot spots occur during locoregional hyperthermia (i.e., heating tumors to 40–44 °C for ~1 h), system settings are adjusted based on experience. In this study, we developed and evaluated treatment planning with temperature-based re-optimization and compared the predicted effectiveness to clinically applied protocol/experience-based steering. Re-optimization times were typically ~10 s; sufficiently fast for on-line use. Effective hot spot suppression was predicted, while maintaining adequate tumor heating. Inducing new hot spots was avoided. Temperature-based re-optimization to suppress treatment limiting hot spots seemed feasible to match the effectiveness of long-term clinical experience and will be further evaluated in a clinical setting. When numerical algorithms are proven to match long-term experience, the overall treatment quality within hyperthermia centers can significantly improve. Implementing these strategies would then imply that treatments become less dependent on the experience of the center/operator. Abstract Background: Experience-based adjustments in phase-amplitude settings are applied to suppress treatment limiting hot spots that occur during locoregional hyperthermia for pelvic tumors. Treatment planning could help to further optimize treatments. The aim of this research was to develop temperature-based re-optimization strategies and compare the predicted effectiveness with clinically applied protocol/experience-based steering. Methods: This study evaluated 22 hot spot suppressions in 16 cervical cancer patients (mean age 67 ± 13 year). As a first step, all potential hot spot locations were represented by a spherical region, with a user-specified diameter. For fast and robust calculations, the hot spot temperature was represented by a user-specified percentage of the voxels with the largest heating potential (HPP). Re-optimization maximized tumor T90, with constraints to suppress the hot spot and avoid any significant increase in other regions. Potential hot spot region diameter and HPP were varied and objective functions with and without penalty terms to prevent and minimize temperature increase at other potential hot spot locations were evaluated. Predicted effectiveness was compared with clinically applied steering results. Results: All strategies showed effective hot spot suppression, without affecting tumor temperatures, similar to clinical steering. To avoid the risk of inducing new hot spots, HPP should not exceed 10%. Adding a penalty term to the objective function to minimize the temperature increase at other potential hot spot locations was most effective. Re-optimization times were typically ~10 s. Conclusion: Fast on-line re-optimization to suppress treatment limiting hot spots seems feasible to match effectiveness of ~30 years clinical experience and will be further evaluated in a clinical setting.
Collapse
|
2
|
Han H, Oberacker E, Kuehne A, Wang S, Eigentler TW, Grass E, Niendorf T. Multi-Channel RF Supervision Module for Thermal Magnetic Resonance Based Cancer Therapy. Cancers (Basel) 2021; 13:1001. [PMID: 33670862 PMCID: PMC7957800 DOI: 10.3390/cancers13051001] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 02/10/2021] [Accepted: 02/23/2021] [Indexed: 01/24/2023] Open
Abstract
Glioblastoma multiforme (GBM) is the most lethal and common brain tumor. Combining hyperthermia with chemotherapy and/or radiotherapy improves the survival of GBM patients. Thermal magnetic resonance (ThermalMR) is a hyperthermia variant that exploits radio frequency (RF)-induced heating to examine the role of temperature in biological systems and disease. The RF signals' power and phase need to be supervised to manage the formation of the energy focal point, accurate thermal dose control, and safety. Patient position during treatment also needs to be monitored to ensure the efficacy of the treatment and avoid damages to healthy tissue. This work reports on a multi-channel RF signal supervision module that is capable of monitoring and regulating RF signals and detecting patient motion. System characterization was performed for a broad range of frequencies. Monte-Carlo simulations were performed to examine the impact of power and phase errors on hyperthermia performance. The supervision module's utility was demonstrated in characterizing RF power amplifiers and being a key part of a feedback control loop regulating RF signals in heating experiments. Electromagnetic field simulations were conducted to calculate the impact of patient displacement during treatment. The supervision module was experimentally tested for detecting patient motion to a submillimeter level. To conclude, this work presents a cost-effective RF supervision module that is a key component for a hyperthermia hardware system and forms a technological basis for future ThermalMR applications.
Collapse
Affiliation(s)
- Haopeng Han
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), 13125 Berlin, Germany; (H.H.); (E.O.); (T.W.E.)
- Humboldt-Universität zu Berlin, Institute of Computer Science, 10099 Berlin, Germany;
| | - Eva Oberacker
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), 13125 Berlin, Germany; (H.H.); (E.O.); (T.W.E.)
- Department of Radiation Oncology and Radiotherapy, Charité Universitätsmedizin Berlin, 13353 Berlin, Germany
| | | | - Shuailin Wang
- Beijing Deepvision Technology Co., Ltd., Beijing 100085, China;
| | - Thomas Wilhelm Eigentler
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), 13125 Berlin, Germany; (H.H.); (E.O.); (T.W.E.)
- Technische Universität Berlin, Chair of Medical Engineering, 10623 Berlin, Germany
| | - Eckhard Grass
- Humboldt-Universität zu Berlin, Institute of Computer Science, 10099 Berlin, Germany;
- IHP–Leibniz-Institut für Innovative Mikroelektronik, 15236 Frankfurt (Oder), Germany
| | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), 13125 Berlin, Germany; (H.H.); (E.O.); (T.W.E.)
- MRI.TOOLS GmbH, 13125 Berlin, Germany;
- Experimental and Clinical Research Center (ECRC), A Joint Cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine, 13125 Berlin, Germany
| |
Collapse
|
3
|
Kok HP, Schooneveldt G, Bakker A, de Kroon-Oldenhof R, Korshuize-van Straten L, de Jong CE, Steggerda-Carvalho E, Geijsen ED, Stalpers LJA, Crezee J. Predictive value of simulated SAR and temperature for changes in measured temperature after phase-amplitude steering during locoregional hyperthermia treatments. Int J Hyperthermia 2018; 35:330-339. [DOI: 10.1080/02656736.2018.1500720] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
Affiliation(s)
- H. P. Kok
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - G. Schooneveldt
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - A. Bakker
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - R. de Kroon-Oldenhof
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - L. Korshuize-van Straten
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - C. E. de Jong
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - E. Steggerda-Carvalho
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - E. D. Geijsen
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - L. J. A. Stalpers
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - J. Crezee
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
4
|
Kok HP, Korshuize-van Straten L, Bakker A, de Kroon – Oldenhof R, Westerveld GH, Versteijne E, Stalpers LJA, Crezee J. Feasibility of on-line temperature-based hyperthermia treatment planning to improve tumour temperatures during locoregional hyperthermia. Int J Hyperthermia 2017; 34:1082-1091. [DOI: 10.1080/02656736.2017.1400120] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
Affiliation(s)
- H. P. Kok
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - L. Korshuize-van Straten
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - A. Bakker
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - R. de Kroon – Oldenhof
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - G. H. Westerveld
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - E. Versteijne
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - L. J. A. Stalpers
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - J. Crezee
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
5
|
Online Adaptive Hyperthermia Treatment Planning During Locoregional Heating to Suppress Treatment-Limiting Hot Spots. Int J Radiat Oncol Biol Phys 2017; 99:1039-1047. [PMID: 28870786 DOI: 10.1016/j.ijrobp.2017.07.011] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Revised: 07/05/2017] [Accepted: 07/10/2017] [Indexed: 01/20/2023]
Abstract
BACKGROUND Adequate tumor temperatures during hyperthermia are essential for good clinical response, but excessive heating of normal tissue should be avoided. This makes locoregional heating using phased array systems technically challenging. Online application of hyperthermia treatment planning could help to improve the heating quality. The aim of this study was to evaluate the clinical benefit of online treatment planning during treatment of pelvic tumors heated with the AMC-8 locoregional hyperthermia system. METHODS For online adaptive hyperthermia treatment planning, a graphical user interface was developed. Electric fields were calculated in a preprocessing step using our in-house-developed finite-difference-based treatment planning system. This allows instant calculation of the temperature distribution for user-selected phase-amplitude settings during treatment and projection onto the patient's computed tomographic scan for online visualization. Online treatment planning was used for 14 treatment sessions in 8 patients to reduce the patients' reports of hot spots while maintaining the same level of tumor heating. The predicted decrease in hot spot temperature should be at least 0.5°C, and the tumor temperature should decrease less than 0.2°C. These predictions were compared with clinical data: patient feedback about the hot spot and temperature measurements in the tumor region. RESULTS In total, 17 hot spot reports occurred during the 14 sessions, and the alternative settings predicted the hot spot temperature to decrease by at least 0.5°C, which was confirmed by the disappearance of all 17 hot spot reports. At the same time, the average tumor temperature was predicted to change on average -0.01°C (range, -0.19°C to 0.34°C). The measured tumor temperature change was on average only -0.02°C (range, -0.26°C to 0.31°C). In only 2 cases the temperature decrease was slightly larger than 0.2°C, but at most it was 0.26°C. CONCLUSIONS Online application of hyperthermia treatment planning is reliable and very useful to reduce hot spots without affecting tumor temperatures.
Collapse
|
6
|
Bardati F, Tognolatti P. Hyperthermia phased arrays pre-treatment evaluation. Int J Hyperthermia 2016; 32:911-922. [DOI: 10.1080/02656736.2016.1219393] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
Affiliation(s)
- Fernando Bardati
- Department of Civil Engineering and Computer Science, University of Rome Tor Vergata, Rome, Italy
| | - Piero Tognolatti
- Department of Industrial and Information Engineering and Economics, University of L’Aquila, L’Aquila, Italy
| |
Collapse
|
7
|
Stauffer PR, van Rhoon GC. Overview of bladder heating technology: matching capabilities with clinical requirements. Int J Hyperthermia 2016; 32:407-16. [PMID: 26939993 DOI: 10.3109/02656736.2016.1141239] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
Moderate temperature hyperthermia (40-45°C for 1 h) is emerging as an effective treatment to enhance best available chemotherapy strategies for bladder cancer. A rapidly increasing number of clinical trials have investigated the feasibility and efficacy of treating bladder cancer with combined intravesical chemotherapy and moderate temperature hyperthermia. To date, most studies have concerned treatment of non-muscle-invasive bladder cancer (NMIBC) limited to the interior wall of the bladder. Following the promising results of initial clinical trials, investigators are now considering protocols for treatment of muscle-invasive bladder cancer (MIBC). This paper provides a brief overview of the devices and techniques used for heating bladder cancer. Systems are described for thermal conduction heating of the bladder wall via circulation of hot fluid, intravesical microwave antenna heating, capacitively coupled radio-frequency current heating, and radiofrequency phased array deep regional heating of the pelvis. Relative heating characteristics of the available technologies are compared based on published feasibility studies, and the systems correlated with clinical requirements for effective treatment of MIBC and NMIBC.
Collapse
Affiliation(s)
- Paul R Stauffer
- a Department of Radiation Oncology , Thomas Jefferson University , Philadelphia , Pennsylvana , USA and
| | - Gerard C van Rhoon
- b Department of Radiation Oncology , Erasmus Medical Centre Cancer Institute , Rotterdam , The Netherlands
| |
Collapse
|
8
|
Shoji H, Motegi M, Osawa K, Okonogi N, Okazaki A, Andou Y, Asao T, Kuwano H, Takahashi T, Ogoshi K. Output-limiting symptoms induced by radiofrequency hyperthermia. Are they predictable? Int J Hyperthermia 2015; 32:199-203. [DOI: 10.3109/02656736.2015.1107760] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
|
9
|
Yuan Y, Cheng KS, Craciunescu OI, Stauffer PR, Maccarini PF, Arunachalam K, Vujaskovic Z, Dewhirst MW, Das SK. Utility of treatment planning for thermochemotherapy treatment of nonmuscle invasive bladder carcinoma. Med Phys 2013; 39:1170-81. [PMID: 22380348 DOI: 10.1118/1.3679839] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE A recently completed Phase I clinical trial combined concurrent Mitomycin-C chemotherapy with deep regional heating using BSD-2000 Sigma-Ellipse applicator (BSD Corporation, Salt Lake City, UT, U.S.A.) for the treatment of nonmuscle invasive bladder cancer. This work presents a new treatment planning approach, and demonstrates potential impact of this approach on improvement of treatment quality. METHODS This study retrospectively analyzes a subset of five patients on the trial. For each treatment, expert operators selected "clinical-optimal" settings based on simple model calculation on the BSD-2000 control console. Computed tomography (CT) scans acquired prior to treatment were segmented to create finite element patient models for retrospective simulations with Sigma-HyperPlan (Dr. Sennewald Medizintechnik GmbH, Munchen, Germany). Since Sigma-HyperPlan does not account for the convective nature of heat transfer within a fluid filled bladder, an effective thermal conductivity for bladder was introduced. This effective thermal conductivity value was determined by comparing simulation results with clinical measurements of bladder and rectum temperatures. Regions of predicted high temperature in normal tissues were compared with patient complaints during treatment. Treatment results using "computed-optimal" settings from the planning system were compared with clinical results using clinical-optimal settings to evaluate potential of treatment improvement by reducing hot spot volume. RESULTS For all five patients, retrospective treatment planning indicated improved matches between simulated and measured bladder temperatures with increasing effective thermal conductivity. The differences were mostly within 1.3 °C when using an effective thermal conductivity value above 10 W/K/m. Changes in effective bladder thermal conductivity affected surrounding normal tissues within a distance of ∼1.5 cm from the bladder wall. Rectal temperature differences between simulation and measurement were large due to sensitivity to the sampling locations in rectum. The predicted bladder T90 correlated well with single-point bladder temperature measurement. Hot spot locations predicted by the simulation agreed qualitatively with patient complaints during treatment. Furthermore, comparison between the temperature distributions with clinical and computed-optimal settings demonstrated that the computed-optimal settings resulted in substantially reduced hot spot volumes. CONCLUSIONS Determination of an effective thermal conductivity value for fluid filled bladder was essential for matching simulation and treatment temperatures. Prospectively planning patients using the effective thermal conductivity determined in this work can potentially improve treatment efficacy (compared to manual operator adjustments) by potentially lower discomfort from reduced hot spots in normal tissue.
Collapse
Affiliation(s)
- Yu Yuan
- Duke University Medical Center, Durham, NC 27710, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Paulides MM, Stauffer PR, Neufeld E, Maccarini PF, Kyriakou A, Canters RAM, Diederich CJ, Bakker JF, Van Rhoon GC. Simulation techniques in hyperthermia treatment planning. Int J Hyperthermia 2013; 29:346-57. [PMID: 23672453 PMCID: PMC3711016 DOI: 10.3109/02656736.2013.790092] [Citation(s) in RCA: 101] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract Clinical trials have shown that hyperthermia (HT), i.e. an increase of tissue temperature to 39-44 °C, significantly enhance radiotherapy and chemotherapy effectiveness [1]. Driven by the developments in computational techniques and computing power, personalised hyperthermia treatment planning (HTP) has matured and has become a powerful tool for optimising treatment quality. Electromagnetic, ultrasound, and thermal simulations using realistic clinical set-ups are now being performed to achieve patient-specific treatment optimisation. In addition, extensive studies aimed to properly implement novel HT tools and techniques, and to assess the quality of HT, are becoming more common. In this paper, we review the simulation tools and techniques developed for clinical hyperthermia, and evaluate their current status on the path from 'model' to 'clinic'. In addition, we illustrate the major techniques employed for validation and optimisation. HTP has become an essential tool for improvement, control, and assessment of HT treatment quality. As such, it plays a pivotal role in the quest to establish HT as an efficacious addition to multi-modality treatment of cancer.
Collapse
Affiliation(s)
- Margarethus M Paulides
- Hyperthermia Unit, Department of Radiation Oncology, Daniel den Hoed Cancer Centre, Erasmus Medical Centre, Rotterdam, The Netherlands.
| | | | | | | | | | | | | | | | | |
Collapse
|
11
|
van Rhoon GC, Samaras T, Yarmolenko PS, Dewhirst MW, Neufeld E, Kuster N. CEM43°C thermal dose thresholds: a potential guide for magnetic resonance radiofrequency exposure levels? Eur Radiol 2013; 23:2215-27. [PMID: 23553588 DOI: 10.1007/s00330-013-2825-y] [Citation(s) in RCA: 183] [Impact Index Per Article: 16.6] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2012] [Revised: 01/30/2013] [Accepted: 02/02/2013] [Indexed: 01/30/2023]
Abstract
OBJECTIVE To define thresholds of safe local temperature increases for MR equipment that exposes patients to radiofrequency fields of high intensities for long duration. These MR systems induce heterogeneous energy absorption patterns inside the body and can create localised hotspots with a risk of overheating. METHODS The MRI + EUREKA research consortium organised a "Thermal Workshop on RF Hotspots". The available literature on thresholds for thermal damage and the validity of the thermal dose (TD) model were discussed. RESULTS/CONCLUSIONS The following global TD threshold guidelines for safe use of MR are proposed: 1. All persons: maximum local temperature of any tissue limited to 39 °C 2. Persons with compromised thermoregulation AND (a) Uncontrolled conditions: maximum local temperature limited to 39 °C (b) Controlled conditions: TD < 2 CEM43°C 3. Persons with uncompromised thermoregulation AND (a) Uncontrolled conditions: TD < 2 CEM43°C (b) Controlled conditions: TD < 9 CEM43°C The following definitions are applied: Controlled conditions A medical doctor or a dedicated trained person can respond instantly to heat-induced physiological stress Compromised thermoregulation All persons with impaired systemic or reduced local thermoregulation KEY POINTS • Standard MRI can cause local heating by radiofrequency absorption. • Monitoring thermal dose (in units of CEM43°C) can control risk during MRI. • 9 CEM43°C seems an acceptable thermal dose threshold for most patients. • For skin, muscle, fat and bone,16 CEM43°C is likely acceptable.
Collapse
Affiliation(s)
- Gerard C van Rhoon
- Department of Radiotherapy, Erasmus MC Cancer Center, Rotterdam, The Netherlands.
| | | | | | | | | | | |
Collapse
|
12
|
Bruggmoser G, Bauchowitz S, Canters R, Crezee H, Ehmann M, Gellermann J, Lamprecht U, Lomax N, Messmer M, Ott O, Abdel-Rahman S, Schmidt M, Sauer R, Thomsen A, Wessalowski R, van Rhoon G. Guideline for the clinical application, documentation and analysis of clinical studies for regional deep hyperthermia. Strahlenther Onkol 2012; 188 Suppl 2:198-211. [DOI: 10.1007/s00066-012-0176-2] [Citation(s) in RCA: 74] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
13
|
Abstract
The hyperthermia effect is based on its thermal influence on tumours. Therefore a controlled heating of the tumours must be achieved. In order to guarantee this, two points must be fulfilled at least: First, the hyperthermia equipment must have the necessary power and steering capability. Second, the distribution of the 'hyperthermic drug', the heat, has to be measured and controlled over the whole treatment time. To reach this aim both a sophisticated technique and a staff trained in hyperthermia are required. In treating patients such as those with cervical cancer, the volume to be exposed and the dosage must be clarified. This means that very special technical and medical conditions must be fulfilled in hyperthermia. To reach and maintain a certain level of quality, hyperthermia is embedded in a framework of procedures. These procedures are defined in the modules of quality management. Therefore quality management must contain specific guidelines for each application, i.e. coordinated standards have to be defined. When adapting these standards in hyperthermia, comparable and comprehensible results of the treatment are guaranteed. Furthermore, an analysis of the treatments under a scientific point of view will be possible and finally result in improvements of this method.
Collapse
Affiliation(s)
- Gregor Bruggmoser
- Department of Radiotherapy, University Hospital of Freiburg, Freiburg, Germany.
| |
Collapse
|
14
|
Linthorst M, Drizdal T, Joosten H, van Rhoon GC, van der Zee J. Procedure for creating a three-dimensional (3D) model for superficial hyperthermia treatment planning. Strahlenther Onkol 2011; 187:835-41. [PMID: 22127361 DOI: 10.1007/s00066-011-2272-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2011] [Accepted: 09/14/2011] [Indexed: 11/24/2022]
Abstract
PURPOSE To make a patient- and treatment-specific computed tomography (CT) scan and to create a three-dimensional (3D) patient model for superficial hyperthermia treatment planning (SHTP). PATIENTS, MATERIALS, AND METHODS Patients with recurrent breast adenocarcinoma in previously irradiated areas referred for radiotherapy (RT) and hyperthermia (HT) treatment and giving informed consent were included. After insertion of the thermometry catheters in the treatment area, a CT scan in the treatment position was made. RESULTS A total of 26 patients have been, thus far, included in the study. During the study period, five types of adjustments were made to the procedure: (1) marking the RT field with radioopaque markers, (2) making the CT scan after the first HT treatment instead of before, (3) using an air- and foam-filled (dummy) water bolus, (4) a change to radiolucent catheters for which radioopaque markers were needed, and (5) marking the visible/palpable extent of the tumor with radioopaque markers, if necessary. With these adjustments, all necessary information is visible on the CT scan. Each CT slice was automatically segmented into muscle, fat, bone, and air. RT field, catheters, applicators, and tumor lesions, if indicated, were outlined manually using the segmentation program iSeg. Next the model was imported into SEMCAD X, a 3D electromagnetic field simulator. CONCLUSION Using the final procedure to obtain a patient- and treatment-specific CT scan, it is possible to create a 3D model for SHTP.
Collapse
Affiliation(s)
- Marianne Linthorst
- Erasmus MC Rotterdam, Department of Radiation Oncology, Hyperthermia Unit, Rotterdam, The Netherlands.
| | | | | | | | | |
Collapse
|
15
|
Bruggmoser G, Bauchowitz S, Canters R, Crezee H, Ehmann M, Gellermann J, Lamprecht U, Lomax N, Messmer MB, Ott O, Abdel-Rahman S, Sauer R, Schmidt M, Thomsen A, Wessalowski R, van Rhoon G. Quality assurance for clinical studies in regional deep hyperthermia. Strahlenther Onkol 2011; 187:605-10. [DOI: 10.1007/s00066-011-1145-x] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2011] [Accepted: 07/04/2011] [Indexed: 10/17/2022]
|
16
|
Kok HP, de Greef M, Borsboom PP, Bel A, Crezee J. Improved power steering with double and triple ring waveguide systems: the impact of the operating frequency. Int J Hyperthermia 2011; 27:224-39. [PMID: 21501024 DOI: 10.3109/02656736.2011.561270] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
INTRODUCTION Regional hyperthermia systems with 3D power steering have been introduced to improve tumour temperatures. The 3D 70-MHz AMC-8 system has two rings of four waveguides. The aim of this study is to evaluate whether T(90) will improve by using a higher operating frequency and whether further improvement is possible by adding a third ring. METHODS Optimised specific absorption rate (SAR) distributions were evaluated for a centrally located target in tissue-equivalent phantoms, and temperature optimisation was performed for five cervical carcinoma patients with constraints to normal tissue temperatures. The resulting T(90) and the thermal iso-effect dose (i.e. the number of equivalent min at 43°C) were evaluated and compared to the 2D 70-MHz AMC-4 system with a single ring of four waveguides. FDTD simulations were performed at 2.5 × 2.5 × 5 mm(3) resolution. The applied frequencies were 70, 100, 120, 130, 140 and 150 MHz. RESULTS Optimised SAR distributions in phantoms showed an optimal SAR distribution at 140 MHz. For the patient simulations, an optimal increase in T(90) was observed at 130 MHz. For a two-ring system at 70 MHz the gain in T(90) was about 0.5°C compared to the AMC-4 system, averaged over the five patients. At 130 MHz the average gain in T(90) was ~1.5°C and ~2°C for a two and three-ring system, respectively. This implies an improvement of the thermal iso-effect dose with a factor ~12 and ~30, respectively. CONCLUSION Simulations showed that a 130-MHz two-ring waveguide system yields significantly higher tumour temperatures compared to 70-MHz single-ring and double-ring waveguide systems. Temperatures were further improved with a 130-MHz triple-ring system.
Collapse
Affiliation(s)
- H P Kok
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands.
| | | | | | | | | |
Collapse
|
17
|
Fatehi D, Van Der Zee J, Van Rhoon GC. Intra-patient comparison between two annular phased array applicators, Sigma-60 and Sigma-Eye: Applied RF powers and intraluminally measured temperatures. Int J Hyperthermia 2011; 27:214-23. [DOI: 10.3109/02656736.2010.541541] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
18
|
Canters RAM, Franckena M, van der Zee J, van Rhoon GC. Optimizing deep hyperthermia treatments: are locations of patient pain complaints correlated with modelled SAR peak locations? Phys Med Biol 2010; 56:439-51. [DOI: 10.1088/0031-9155/56/2/010] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
19
|
Bakker JF, Paulides MM, Westra AH, Schippers H, Van Rhoon GC. Design and test of a 434 MHz multi-channel amplifier system for targeted hyperthermia applicators. Int J Hyperthermia 2010; 26:158-70. [PMID: 20146570 DOI: 10.3109/02656730903341191] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
PURPOSE For our head-and-neck hyperthermia (HT) applicator, an amplifier system with full amplitude and phase-control to deliver the radio-frequency signals, was not available. We therefore designed and tested a 433.92 MHz multi-channel amplifier system. SYSTEM DESCRIPTION The design consists of a direct digital synthesizer (DDS) system that generates 12 phase-controlled coherent 433.92 MHz signals, which are amplified to maximum 200 W output per channel. Directional couplers are placed at the amplifiers to couple a small portion of both forward and reflected signals to gain-and-phase detectors. The power setting is applied with a resolution of 2 W and for the phase it is 0.1 degrees . The channels are sequentially sampled at 100 Hz per channel. METHODS We tested the performance of the designed amplifier system by measuring the RF spectrum, power and phase accuracy, and by characterising the feedback control by using highly accurate power and phase meters. RESULTS The spurious emission is less than 60 dBc and the first two harmonic frequencies are suppressed more than 45 dB. The measurement accuracy for the power (+/-5%) is valid for at least 20 days after calibration and for the phase (+/-5 degrees ) it is valid for at least 2 months. CONCLUSIONS The amplifier system operates according to our design criteria to support targeted HT. It can be used for both our in-house developed superficial and head-and-neck HT applicators or any other HT applicator that works on the same frequency of 433.92 MHz.
Collapse
Affiliation(s)
- J F Bakker
- Department of Radiation Oncology, Erasmus MC-Daniel den Hoed Cancer Center, Rotterdam, The Netherlands.
| | | | | | | | | |
Collapse
|
20
|
Abstract
PURPOSE OF REVIEW We reviewed all literature on the clinical use of combined radiation and hyperthermia for gynecologic malignancies. RECENT FINDINGS Combined radiation and hyperthermia should be considered an alternative to chemoradiation for patients with locally advanced cervix cancer and be the first treatment of choice for these patients when radiation cannot be combined with chemotherapy. Several randomized trials have shown an improvement by adding hyperthermia to radiation that is comparable to the improvement found with the addition of chemotherapy to radiation. Hyperthermia does not seem to add to treatment-induced toxicity and the results of hyperthermia are consistent even at 12 years follow-up and could be reproduced in a large, unselected group of cervix cancer patients. A novel indication for combined radiotherapy and hyperthermia is vaginal cancer. Recently, a cohort study showed that the addition of hyperthermia to radiation seems to improve overall survival for patients with vaginal cancer International Federation of Gynecology and Obstetrics stage III. SUMMARY Combined radiation and hyperthermia should be considered for patients with locally advanced cervix cancer (International Federation of Gynecology and Obstetrics stage IIb and upwards) as an alternative to chemoradiation for patients with a contraindication for chemotherapy. For other patients, the optimal treatment combination is the subject of randomized trials. For vaginal cancer, a prospective registration study is currently ongoing.
Collapse
|
21
|
Franckena M, Canters R, Termorshuizen F, Van Der Zee J, Van Rhoon G. Clinical implementation of hyperthermia treatment planning guided steering: A cross over trial to assess its current contribution to treatment quality. Int J Hyperthermia 2010; 26:145-57. [DOI: 10.3109/02656730903453538] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
22
|
Canters RAM, Wust P, Bakker JF, Van Rhoon GC. A literature survey on indicators for characterisation and optimisation of SAR distributions in deep hyperthermia, a plea for standardisation. Int J Hyperthermia 2010; 25:593-608. [PMID: 19848621 DOI: 10.3109/02656730903110539] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
PURPOSE To evaluate the predictive value of SAR indicators by assessing the correlation of a SAR indicator with the corresponding predicted temperature. Ultimately, this should lead to a number of verified SAR indicators for characterization and optimization of a predicted SAR distribution. METHODS A literature survey is followed by an evaluation of the SAR indicators on their functionality, using a set of heuristic classification criteria. To obtain an objective assessment of the predictive value for SAR characterisation, all SAR indicators are evaluated by correlating the value of the SAR indicator to the predicted target temperature when heated with the BSD2000 Sigma 60 applicator. Two methods were followed. First, the specificity of the SAR indicator to target temperature was assessed for each of the 36 patient-specific models, using 30 randomly chosen phase and amplitude settings. Secondly, each SAR indicator was used as a goal function to assess its suitability for optimisation purposes. RESULTS Only a selected number of SAR indicators correlate well with tumour/target-temperature. Hence, for target-related properties, an adequate set of SAR indicators is found in the literature. For hotspots, modifications are desirable. For optimisation purposes, improved objective functions have been defined. CONCLUSIONS From the correlation of the SAR indicators with tumour temperature, a preferred set of SAR indicators is derived: For target heating, 'average SAR ratio', 'Hotspot-target SAR ratio', and 'homogeneity coefficient' provide suitable objective criteria, while for hotspot reduction, 'Hotspot-target SAR ratio' is considered the most useful indicator. For optimisation procedures, 'Hotspot-target SAR ratio' is currently the most suitable objective function.
Collapse
Affiliation(s)
- R A M Canters
- Erasmus Medical Center, Radiation Oncology Department, Hyperthermia Unit, Rotterdam, The Netherlands.
| | | | | | | |
Collapse
|
23
|
Borkamo ED, Schem BC, Fluge Ø, Bruland O, Dahl O, Mella O. cDNA microarray analysis of serially sampled cervical cancer specimens from patients treated with thermochemoradiotherapy. Int J Radiat Oncol Biol Phys 2009; 75:1562-9. [PMID: 19931738 DOI: 10.1016/j.ijrobp.2009.08.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2009] [Revised: 06/16/2009] [Accepted: 08/13/2009] [Indexed: 11/28/2022]
Abstract
PURPOSE To elucidate changes in gene expression after treatment with regional thermochemoradiotherapy in locally advanced squamous cell cervical cancer. METHODS AND MATERIALS Tru-Cut biopsy specimens were serially collected from 16 patients. Microarray gene expression levels before and 24 h after the first and second trimodality treatment sessions were compared. Pathway and network analyses were conducted by use of Ingenuity Pathways Analysis (IPA; Ingenuity Systems, Redwood City, CA). Single gene expressions were analyzed by quantitative real-time reverse transcription-polymerase chain reaction. RESULTS We detected 53 annotated genes that were differentially expressed after trimodality treatment. Central in the three top networks detected by IPA were interferon alfa, interferon beta, and interferon gamma receptor; nuclear factor kappaB; and tumor necrosis factor, respectively. These genes encode proteins that are important in regulation cell signaling, proliferation, gene expression, and immune stimulation. Biological processes over-represented among the 53 genes were fibrosis, tumorigenesis, and immune response. CONCLUSIONS Microarrays showed minor changes in gene expression after thermochemoradiotherapy in locally advanced cervical cancer. We detected 53 differentially expressed genes, mainly involved in fibrosis, tumorigenesis, and immune response. A limitation with the use of serial biopsy specimens was low quality of ribonucleic acid from tumors that respond to highly effective therapy. Another "key limitation" is timing of the post-treatment biopsy, because 24 h may be too late to adequately assess the impact of hyperthermia on gene expression.
Collapse
Affiliation(s)
- Erling Dahl Borkamo
- Section of Oncology, Institute of Medicine, University of Bergen, Bergen, Norway.
| | | | | | | | | | | |
Collapse
|
24
|
Canters RAM, Franckena M, Paulides MM, Van Rhoon GC. Patient positioning in deep hyperthermia: influences of inaccuracies, signal correction possibilities and optimization potential. Phys Med Biol 2009; 54:3923-36. [DOI: 10.1088/0031-9155/54/12/021] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|