1
|
Yamasaki K, Dantam J, Sasanuma K, Hisamura R, Mizuno Y, Hui A, Jones L. Impact of in vitro lens deposition and removal on bacterial adhesion to orthokeratology contact lenses. Cont Lens Anterior Eye 2024; 47:102104. [PMID: 38161140 DOI: 10.1016/j.clae.2023.102104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 11/22/2023] [Accepted: 12/11/2023] [Indexed: 01/03/2024]
Abstract
PURPOSE The purpose of this study was to explore the impact of several contact lens (CL) care solutions on the removal of proteins and lipids, and how deposit removal impacts bacterial adhesion and solution disinfection. METHODS Lysozyme and lipid deposition on three ortho-k (rigid) and two soft CL materials were evaluated using an ELISA kit and gas chromatography respectively. Bacterial adhesion to a fluorosilicone acrylate material using Pseudomonas aeruginosa with various compositions of artificial tear solutions (ATS), including with denatured proteins, was also investigated. The impact of deposition of the different formulations of ATS on biofilm formation was explored using cover slips. Finally, the lysozyme and lipid cleaning efficacy and disinfection efficacy against P. aeruginosa and Staphylococcus aureus of four different contact lens care solutions were studied using qualitative analysis. RESULTS While maximum lysozyme deposition was observed with the fluorosilicone acrylate material (327.25 ± 54.25 µg/lens), the highest amount of lipid deposition was recorded with a fluoro-siloxanyl styrene material (134.71 ± 19.87 µg/lens). Adhesion of P. aeruginosa to fluorosilicone acrylate lenses and biofilm formation on cover slips were significantly greater with the addition of denatured proteins and lipids. Of the four contact lens care solutions investigated, the solution based on povidone-iodine removed both denatured lysozyme and lipid deposits and could effectively disinfect against P. aeruginosa and S. aureus when contaminated with denatured proteins and lipids. In contrast, the peroxide-based solution was able to inhibit P. aeruginosa growth only, while the two multipurpose solutions were unable to disinfect lenses contaminated with denatured proteins and lipids. CONCLUSION Bacterial adhesion and biofilm formation is influenced by components within artificial tear solutions depositing on lenses, including denatured proteins and lipids, which also affects disinfection. The ability of different solutions to remove these deposits should be considered when selecting systems to clean and disinfect ortho-k lenses.
Collapse
Affiliation(s)
| | - Jaya Dantam
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Ontario, Canada
| | | | | | - Yohei Mizuno
- Kobe Research Center, OPHTECS Corporation, Kobe, Japan
| | - Alex Hui
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Ontario, Canada; School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, Australia.
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Ontario, Canada; Centre for Eye and Vision Research (CEVR), Hong Kong Special Administrative Region, Hong Kong
| |
Collapse
|
2
|
Majdoub F, Belin M, Perret-Liaudet J. Ultra-low friction in soft contact lenses: Analysis of dynamic free responses measured by the dynamic oscillating tribometer. J Mech Behav Biomed Mater 2024; 149:106236. [PMID: 37984287 DOI: 10.1016/j.jmbbm.2023.106236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 11/06/2023] [Accepted: 11/08/2023] [Indexed: 11/22/2023]
Abstract
Friction coefficient is considered as a measurement for clinical comfort of soft contact lenses. One of the main challenges in the tribology field is to evaluate the friction in soft materials such as soft contact lenses. In this work, we aim to evaluate the friction at the eyelid-lens contact using a new technique. This technique is based on a single-degree-of-freedom (SDOF) mass-spring system having a sliding contact. The experimental technique measures the free responses of the mechanical system. The friction is then evaluated from the damped free responses with a high accuracy. A variety of soft contact lenses are tested with some lubricants under many physiological conditions. The results are discussed and compared with those in the literature.
Collapse
Affiliation(s)
- Fida Majdoub
- LabECAM, ECAM La Salle, Université de Lyon, 69005, Lyon, France.
| | - Michel Belin
- Laboratory of Tribology and System Dynamics, École Centrale de Lyon, UMR CNRS 5513, Université de Lyon, 69134, Écully, France
| | - Joël Perret-Liaudet
- Laboratory of Tribology and System Dynamics, École Centrale de Lyon, UMR CNRS 5513, Université de Lyon, 69134, Écully, France
| |
Collapse
|
3
|
Effect of poly(ethylene glycol) methacrylate on the ophthalmic properties of silicone hydrogel contact lenses. Colloids Surf B Biointerfaces 2022. [DOI: 10.1016/j.colsurfb.2022.112713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
4
|
Masoudi S, Willcox M. Development of an enzymatic method for the evaluation of protein deposition on contact lenses. BIOFOULING 2022; 38:84-99. [PMID: 35016572 DOI: 10.1080/08927014.2021.2019225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 12/09/2021] [Accepted: 12/10/2021] [Indexed: 06/14/2023]
Abstract
The aim of this study was to evaluate a new digestion method to quantify protein deposition on contact lenses. Four silicone hydrogel and one hydrogel contact lens material were incubated in lactoferrin, lysozyme, immunoglobulin A, and bovine serum albumin solutions at approximate physiological concentrations and temperature. Immobilized trypsin was used to digest the protein deposits from the contact lens surfaces. The total protein absorbed to lenses was extracted and digested using sequencing grade trypsin. The tryptic peptides were quantified using selected reaction monitoring mass spectrometry. The concentration of surface protein deposits was either lower than or the same as the total protein for all lens types and proteins. Immobilised trypsin can digest protein deposits from the surface of contact lenses. This ability to analyse the amount of protein at a contact lens surface may help in elucidating the effect of surface deposition on clinical outcomes during lens wear.
Collapse
Affiliation(s)
- Simin Masoudi
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| | - Mark Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| |
Collapse
|
5
|
Masoudi S, Willcox M. A method for studying lipid adsorption to silicone hydrogel contact lenses. BIOFOULING 2021; 37:862-878. [PMID: 34615411 DOI: 10.1080/08927014.2021.1978433] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 08/30/2021] [Accepted: 09/02/2021] [Indexed: 06/13/2023]
Abstract
The aim of this study was to develop an experimental methodology to measure lipid deposition with contact lenses. Contact lenses were incubated in a lipid solution. The amount and types of adsorbed lipids were assessed using mass spectrometry and confocal microscopy. The recovery of lipids from lenses varied with lipid and lens type. Most non-polar and polar lipids were desorbed from lenses during the first 5 min of extraction. Fluorescently labelled phosphatidylcholine bound within the matrix of Senofilcon A lenses but to the surface of Lotrafilcon B lenses, whereas fluorescently labelled cholesteryl ester was found throughout both lenses. The efficacy of extraction of lipids from contact lenses varies for different lipid classes and different lens materials. Differences in the amount and time of lipid desorption probably resulted from the strength of the bond between lipid and lens polymer and the depth of adsorption of lipid in the polymer.
Collapse
Affiliation(s)
- Simin Masoudi
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Mark Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
6
|
Walther H, Lorentz H, Heynen M, Kay L, Jones LW. The Impact of Incubation Conditions on In Vitro Phosphatidylcholine Deposition on Contact Lens Materials. Optom Vis Sci 2021; 98:341-349. [PMID: 33828039 DOI: 10.1097/opx.0000000000001680] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
SIGNIFICANCE Previous in vitro measurements of contact lenses commonly investigate the impact of nonpolar tear film lipids (i.e., sterols). Polar lipids, however, are equally important stabilizing components of the tear film. This research explores and presents further knowledge about various aspects of polar lipid uptake that may impact contact lens performance. PURPOSE This study evaluated the impact of incubation time, lipid concentration, and replenishment of an artificial tear solution (ATS) on the uptake of phosphatidylcholine (PC) onto conventional hydrogel (CH) and silicone hydrogel (SH) contact lens materials. METHODS Four SHs and two CH lens materials (n = 4) were soaked in a complex ATS containing radioactive 14C-PC as a probe molecule. Phosphatidylcholine uptake was monitored at various incubation time points (1, 3, 7, 14, and 28 days), with different ATS lipid concentrations (0.5×, 1×, 2×) and with and without regular replenishment of the ATS. Phosphatidylcholine was extracted from the lenses, processed, and counted by a β counter, and accumulated PC (μg/lens) was extrapolated from standard lipid calibration curves. RESULTS All materials exhibited increasing PC deposition over time. Conventional hydrogel materials showed significantly lower PC uptake rates (P < .001) than any of the SH materials. Increasing lipid concentration in the ATS resulted in increased PC binding onto the contact lens materials (P < .001). Replenishing the ATS every other day, however, impacted the PC deposition differently, showing increased binding (P < .001) on CHs and reduced PC deposition for SH materials (P < .001). CONCLUSIONS Length of incubation, lipid concentration in the ATS, and renewal of the incubation solution all influenced the amount of PC that sorbed onto various lens materials and therefore need to be considered when conducting future in vitro deposition studies.
Collapse
Affiliation(s)
| | | | - Miriam Heynen
- Centre for Ocular Research & Education, School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Lise Kay
- Centre for Ocular Research & Education, School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | | |
Collapse
|
7
|
Phan CM, Qiao H, Yee A, Jones L. Deposition of Fluorescently Tagged Lysozyme on Contact Lenses in a Physiological Blink Model. Eye Contact Lens 2021; 47:127-133. [PMID: 31789754 DOI: 10.1097/icl.0000000000000683] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/02/2019] [Indexed: 11/25/2022]
Abstract
PURPOSE To visualize the deposition of fluorescein isothiocyanate (FITC) lysozyme on daily disposable contact lenses (CLs) using a novel blink model. METHODS Three daily disposable conventional hydrogel CLs (etafilcon A, omafilcon A, and nelfilcon A) and three silicone hydrogel CLs (delefilcon A, senofilcon A, and somofilcon A) were evaluated in the study. The CLs were mounted onto a novel blink model and exposed to an artificial tear solution containing FITC lysozyme for 2 and 10 hr. The flow rate and blink speed were set to 1 μL/min and 6 blinks/min, respectively. After the incubation period, a 5-mm-diameter disc was punched out from the center of the lens and mounted on a microscope slide. The slides were imaged using the Zeiss 510 Meta confocal laser scanning microscope, which scanned the lens from the front to the back surface at 5-μm increments. RESULTS There was an increase in deposition of FITC lysozyme for all lens types with increasing incubation time (P<0.05), with the exception of somofilcon A, which did not show statistical significance between 2 and 10 hr (P>0.05). The conventional hydrogel CLs deposited higher amounts of FITC lysozyme than the silicone hydrogel CLs (P<0.001), with etafilcon A depositing the highest at all time points (P<0.05). Interestingly, at the 2-hr incubation time, most CLs showed a higher amount of deposition at the front surface than the back surface of the lens. In particular, etafilcon A showed preferred deposition at the front surface at all time points. CONCLUSION The results suggest that there is differential deposition at the front surface of the CL, which is exposed to the prelens tear film, compared with the back surface of the CL, which is exposed to the postlens tear film. Therefore, it may be beneficial to design CL materials with differing surface properties for the front and back surfaces of the CL to enhance interactions with the tear film and ocular surface.
Collapse
Affiliation(s)
- Chau-Minh Phan
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | | | | | | |
Collapse
|
8
|
Qiao H, Luensmann D, Heynen M, Drolle E, Subbaraman LN, Scales C, Riederer D, Fadli Z, Jones L. In vitro Evaluation of the Location of Cholesteryl Ester Deposits on Monthly Replacement Silicone Hydrogel Contact Lens Materials. Clin Ophthalmol 2020; 14:2821-2828. [PMID: 33061266 PMCID: PMC7522414 DOI: 10.2147/opth.s270575] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2020] [Accepted: 08/22/2020] [Indexed: 11/23/2022] Open
Abstract
Purpose The deposition profile of cholesteryl ester on the surface and throughout the matrix of silicone hydrogel contact lens (CL) materials was determined under conditions that mimic a daily wear regimen. Methods In this in vitro study, four SiHy CL materials (senofilcon C, lotrafilcon B, comfilcon A and samfilcon A) were incubated in an artificial tear solution (ATS) for up to 30 days. CL incubation was alternated between the ATS (16 hours) and a multipurpose care regimen (8 hours). The ATS included fluorescently tagged cholesteryl ester (5-cholesten-3ß-ol 6-[(7-nitro-2-1,3-benzoxadiazol-4-yl)amino]caproate; CE-NBD) and confocal laser scanning microscopy visualized the distribution of the lipid through the CLs. Results The distribution of CE-NBD was homogenous from the anterior to posterior surface in senofilcon C and comfilcon A, at all time points. For lotrafilcon B and samfilcon A, CE-NBD localization was heterogeneous, with greater amounts on the surfaces on Day 1 and Day 14 compared to the lens matrix; however, differences in concentration between the surface and bulk diminished by Day 30. Conclusion The distribution of the non-polar lipid CE-NBD varied with lens material chemistry. While some lens materials deposited the lipid primarily on the surface after 16 hours of exposure, all materials exhibited a homogenous distribution after one month.
Collapse
Affiliation(s)
- Han Qiao
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada
| | - Doerte Luensmann
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada
| | - Miriam Heynen
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada
| | - Elizabeth Drolle
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada
| | - Lakshman N Subbaraman
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada
| | - Charles Scales
- Johnson & Johnson Vision Care, Inc, Jacksonville, FL, USA
| | | | - Zohra Fadli
- Johnson & Johnson Vision Care, Inc, Jacksonville, FL, USA
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada.,Centre for Eye & Vision Research (CEVR), Hong Kong, People's Republic of China
| |
Collapse
|
9
|
Efron N, Brennan NA, Chalmers RL, Jones L, Lau C, Morgan PB, Nichols JJ, Szczotka-Flynn LB, Willcox MD. Thirty years of 'quiet eye' with etafilcon A contact lenses. Cont Lens Anterior Eye 2020; 43:285-297. [PMID: 32278644 DOI: 10.1016/j.clae.2020.03.015] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Revised: 03/27/2020] [Accepted: 03/28/2020] [Indexed: 11/17/2022]
Abstract
Frequent replacement contact lenses made from the etafilcon A hydrogel lens material were introduced onto the market over 30 years ago, and etafilcon A remains the most widely used hydrogel lens material today. Although the prescribing of silicone hydrogel lenses is increasing, millions of lens wearers globally have been wearing hydrogel lenses for many years and exhibit a physiologically-stable 'quiet eye', with a low profile of adverse events. Hydrogel lenses are demonstrated to maintain a low inflammatory response and infection risk profile during daily wear, which in the case of etafilcon A, may be related to its low modulus, and the naturally-protective, anti-microbial, non-denatured lysozyme absorbed into the lens from the tear fluid. Although improved corneal physiology from decreased hypoxia with silicone hydrogel lenses is well accepted, equivalent levels of corneal oxygenation are maintained during daily wear of low to medium powered hydrogel lenses, which do not impede the daily corneal de-swelling process, and do not induce clinically significant changes in ocular health. Therefore, hydrogel lenses remain an important alternative for daily wear in modern contact lens practice.
Collapse
Affiliation(s)
- Nathan Efron
- Institute of Health and Biomedical Innovation, School of Optometry and Vision Science, Queensland University of Technology, Australia.
| | | | | | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada
| | - Charis Lau
- Johnson & Johnson Vision, Inc, Jacksonville, FL, USA
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, UK
| | - Jason J Nichols
- The University of Alabama at Birmingham, School of Optometry, Birmingham, AL, USA
| | - Loretta B Szczotka-Flynn
- University Hospitals Eye Institute, University Hospitals Cleveland Medical Center, Department of Ophthalmology & Visual Sciences, Case Western Reserve University, Cleveland, OH, USA
| | - Mark D Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
10
|
Cheung S, Subbaraman LN, Ngo W, Jay GD, Schmidt TA, Jones L. Localization of full-length recombinant human proteoglycan-4 in commercial contact lenses using confocal microscopy. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2019; 31:110-122. [PMID: 31594478 DOI: 10.1080/09205063.2019.1678454] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
The aim of this study was to determine the sorption location of full-length recombinant human proteoglycan 4 (rhPRG4) tagged with fluorescein isothiocyanate (FITC) to four silicone hydrogel contact lenses [balafilcon A (PureVision, Bausch + Lomb), senofilcon A (Acuvue Oasys, Johnson & Johnson), comfilcon A (Biofinity, CooperVision), lotrafilcon B (Air Optix, Alcon)] and one conventional hydrogel lens [etafilcon A (Acuvue 2, Johnson & Johnson)], using confocal laser scanning microscopy (CLSM). Lenses (n = 3 each) were incubated under two conditions: (1) FITC-rhPRG4 solution at 300 μg/mL and (2) phosphate-buffered saline, for 1 h at 37 °C in darkness with gentle shaking. The central 4 mm of each lens was removed and viewed with the Zeiss 510 CLSM using an argon laser at 488 nm (FITC excitation 495 nm, emission 521 nm). Depth scans were taken at 1 μm intervals to a maximum depth of 100 μm. All lens materials demonstrated sorption of rhPRG4. Both senofilcon A and balafilcon A revealed FITC-rhPRG4 penetration into the bulk of the lens, generally favoring the surface. rhPRG4 was observed exclusively on the surface of lotrafilcon B, with no presence within the bulk of the lens. rhPRG4 was evenly distributed throughout the bulk of the lens, as well as on the surface, for comfilcon A and etafilcon A. The sorption profile of FITC-rhPRG4 was successfully visualized using CLSM in various contact lens materials. The polymer composition, surface treatment and pore size of the material can influence the sorption of rhPRG4.
Collapse
Affiliation(s)
- Steven Cheung
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Lakshman N Subbaraman
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - William Ngo
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Gregory D Jay
- Department of Emergency Medicine, Alpert Medical School & School of Engineering, Brown University, Providence, Rhode Island, USA
| | - Tannin A Schmidt
- Faculty of Kinesiology & Schulich School of Engineering, University of Calgary, Calgary, Alberta, Canada.,Biomedical Engineering Department, University of Connecticut Health Center, Farmington, Connecticut, USA
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| |
Collapse
|
11
|
The influence of protein deposition on contact lens tear film stability. Colloids Surf B Biointerfaces 2019; 180:229-236. [DOI: 10.1016/j.colsurfb.2019.04.051] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Revised: 04/18/2019] [Accepted: 04/24/2019] [Indexed: 11/22/2022]
|
12
|
Depth Profile Assessment of the Early Phase Deposition of Lysozyme on Soft Contact Lens Materials Using a Novel In Vitro Eye Model. Eye Contact Lens 2018; 44 Suppl 2:S11-S18. [DOI: 10.1097/icl.0000000000000397] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
13
|
Efficacy of Contact Lens Care Solutions in Removing Cholesterol Deposits From Silicone Hydrogel Contact Lenses. Eye Contact Lens 2018; 45:105-111. [PMID: 30199424 DOI: 10.1097/icl.0000000000000547] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To determine the efficacy of multipurpose solutions (MPSs) on the removal of cholesterol deposits from silicone hydrogel (SH) contact lens materials using an in vitro model. MATERIALS AND METHODS Five SH lens materials: senofilcon A, comfilcon A, balafilcon A, lotrafilcon A, and lotrafilcon B were removed from the blister pack (n=4 for each lens type), incubated for 7 days at 37°C in an artificial tear solution containing C radiolabeled cholesterol. Thereafter, lenses were stored in a preserved saline solution control (Sensitive Eyes Saline Plus) or cleaned with 1 of the 5 MPSs incorporating different preservatives (POLYQUAD/ALDOX, polyquaternium-1/alexidine, polyquaternium-1/PHMB, and 2 based on PHMB alone) using a rub and rinse technique, according to the manufacturer's recommendations, and stored in the MPS for a minimum of 6 hr. Lenses were then extracted with 2:1 chloroform:methanol, analyzed in a beta counter, and μg/lens of cholesterol was determined. RESULTS Balafilcon A and senofilcon A lens materials showed the highest amounts of accumulated cholesterol (0.93±0.02 μg/lens; 0.95±0.01 μg/lens, respectively), whereas lotrafilcon A and lotrafilcon B deposited the lowest amounts (0.37±0.03 μg/lens; 0.47±0.12 μg/lens, respectively). For all lens materials, the MPS preserved with POLYQUAD/ALDOX removed more deposited cholesterol than any other test solution; however, the amount of removed cholesterol contamination from the individual contact lenses was only statistically significant for balafilcon A and senofilcon A (P=0.006 and P=0.042, respectively). Sensitive eyes and the other evaluated MPSs showed no significant effect on cholesterol removal (P>0.05). CONCLUSION Cholesterol-removal efficacy varies depending on the combination of lens material and solution. Only 1 MPS showed a statistically significant reduction of cholesterol deposit for only 2 of the 5 tested lens materials.
Collapse
|
14
|
Walther H, Phan CM, Subbaraman LN, Jones L. Differential Deposition of Fluorescently Tagged Cholesterol on Commercial Contact Lenses Using a Novel In Vitro Eye Model. Transl Vis Sci Technol 2018; 7:18. [PMID: 29644148 PMCID: PMC5892225 DOI: 10.1167/tvst.7.2.18] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2017] [Accepted: 02/17/2018] [Indexed: 11/24/2022] Open
Abstract
Purpose We evaluate the differences in lipid uptake and penetration in daily disposable (DD) contact lenses (CL) using a conventional “in-vial” method compared to a novel in vitro eye model. Methods The penetration of fluorescently labelled 22-(N-(7-Nitrobenz-2-Oxa-1,3-Diazol-4-yl)Amino)-23,24-Bisnor-5-Cholen-3beta-Ol (NBD)–cholesterol on three silicone hydrogel (SH) and four conventional hydrogel (CH) DD CLs were investigated. CLs were incubated for 4 and 12 hours in a vial, containing 3.5 mL artificial tear solution (ATS), or were mounted on an in vitro eye-blink platform designed to simulate physiologic tear flow (2 mL/24 hours), tear volume and “simulated” blinking. Subsequently, CLs were analyzed using laser scanning confocal microscopy and ImageJ. Results Penetration depth and fluorescence intensities of NBD-cholesterol varied between the incubation methods as well as lens materials. Using the traditional vial incubation method, NBD-cholesterol uptake occurred equally on both sides of all lens materials. However, using our eye-blink model, cholesterol penetration was observed primarily on the anterior surface of the CLs. In general, SH lenses showed higher intensities of NBD-cholesterol than CH materials. Conclusions The traditional “in-vial” incubation method exposes the CLs to an excessively high amount of ATS, which results in an overestimation for cholesterol deposition. Our model, which incorporates important ocular factors, such as intermittent air exposure, small tear volume, and physiological tear flow between blinks, provides a more natural environment for in vitro lens incubation. Translational Relevance In vitro measurements of CLs are a common approach to predict their interactions and performance on the eye. Traditional methods, however, are rudimentary. Therefore, this study presents a novel in vitro model to evaluate CLs, which consequently will enhance elucidations of the interactions between CLs and the eye.
Collapse
Affiliation(s)
- Hendrik Walther
- Centre for Ocular Research & Education (CORE) - formerly Centre for Contact Lens Research (CCLR), School of Optometry and Vision Science, Waterloo, Ontario, Canada
| | - Chau-Minh Phan
- Centre for Ocular Research & Education (CORE) - formerly Centre for Contact Lens Research (CCLR), School of Optometry and Vision Science, Waterloo, Ontario, Canada
| | - Lakshman N Subbaraman
- Centre for Ocular Research & Education (CORE) - formerly Centre for Contact Lens Research (CCLR), School of Optometry and Vision Science, Waterloo, Ontario, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE) - formerly Centre for Contact Lens Research (CCLR), School of Optometry and Vision Science, Waterloo, Ontario, Canada
| |
Collapse
|
15
|
Liu J, Christophersen PC, Yang M, Nielsen HM, Mu H. The impact of particle preparation methods and polymorphic stability of lipid excipients on protein distribution in microparticles. Drug Dev Ind Pharm 2017; 43:2032-2042. [DOI: 10.1080/03639045.2017.1361967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Affiliation(s)
- Jingying Liu
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Philip C. Christophersen
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Mingshi Yang
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
- Wuya College of Innovation, Shenyang Pharmaceutical University, Shenyang, China
| | - Hanne M. Nielsen
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Huiling Mu
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
16
|
Heynen M, Babaei Omali N, Fadli Z, Coles-Brennan C, Subbaraman LN, Jones L. Selectivity and localization of lysozyme uptake in contemporary hydrogel contact lens materials. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2017; 28:1351-1364. [DOI: 10.1080/09205063.2017.1327751] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Affiliation(s)
- Miriam Heynen
- Centre for Contact Lens Research, School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada
| | - Negar Babaei Omali
- Centre for Contact Lens Research, School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada
| | - Zohra Fadli
- Johnson & Johnson Vision Care Inc., Jacksonville, FL, USA
| | | | - Lakshman N. Subbaraman
- Centre for Contact Lens Research, School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada
| | - Lyndon Jones
- Centre for Contact Lens Research, School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada
| |
Collapse
|
17
|
A Review of Techniques to Measure Protein Sorption to Soft Contact Lenses. Eye Contact Lens 2017; 43:276-286. [PMID: 28198731 DOI: 10.1097/icl.0000000000000366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To compare and critically evaluate a variety of techniques to measure the quantity and biological activity of protein sorption to contact lenses over short time periods. METHODS A literature review was undertaken investigating the major techniques to measure protein sorption to soft contact lens materials, with specific reference to measuring protein directly on lenses using in situ, ex situ, protein structural, and biological activity techniques. RESULTS The use of in situ techniques to measure protein quantity provides excellent sensitivity, but many are not directly applicable to contact lenses. Many ex situ techniques struggle to measure all sorbed proteins, and these measurements can have significant signal interference from the lens materials themselves. Techniques measuring the secondary and tertiary structures of sorbed proteins have exhibited only limited success. CONCLUSIONS There are a wide variety of techniques to measure both the amount of protein and the biological activity of protein sorbed to soft contact lens materials. To measure the mass of protein sorbed to soft contact lenses (not just thin films) over short time periods, the method of choice should be I radiolabeling. This technique is sensitive enough to measure small amounts of deposited protein, provided steps are taken to limit and measure any interaction of the iodine tracer with the materials. To measure the protein activity over short time periods, the method of choice should be to measure the biological function of sorbed proteins. This may require new methods or adaptations of existing ones.
Collapse
|
18
|
Phan CM, Walther H, Gao H, Rossy J, Subbaraman LN, Jones L. Development of an In Vitro Ocular Platform to Test Contact Lenses. J Vis Exp 2016:e53907. [PMID: 27078088 DOI: 10.3791/53907] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
Currently, in vitro evaluations of contact lenses (CLs) for drug delivery are typically performed in large volume vials, which fail to mimic physiological tear volumes. The traditional model also lacks the natural tear flow component and the blinking reflex, both of which are defining factors of the ocular environment. The development of a novel model is described in this study, which consists of a unique 2-piece design, eyeball and eyelid piece, capable of mimicking physiological tear volume. The models are created from 3-D printed molds (Polytetrafluoroethylene or Teflon molds), which can be used to generate eye models from various polymers, such as polydimethylsiloxane (PDMS) and agar. Further modifications to the eye pieces, such as the integration of an explanted human or animal cornea or human corneal construct, will permit for more complex in vitro ocular studies. A commercial microfluidic syringe pump is integrated with the platform to emulate physiological tear secretion. Air exposure and mechanical wear are achieved using two mechanical actuators, of which one moves the eyelid piece laterally, and the other moves the eyeballeyepiece circularly. The model has been used to evaluate CLs for drug delivery and deposition of tear components on CLs.
Collapse
Affiliation(s)
- Chau-Minh Phan
- School of Optometry and Vision Science, University of Waterloo;
| | - Hendrik Walther
- School of Optometry and Vision Science, University of Waterloo
| | | | - Jordan Rossy
- School of Optometry and Vision Science, University of Waterloo
| | | | - Lyndon Jones
- School of Optometry and Vision Science, University of Waterloo
| |
Collapse
|
19
|
Omali NB, Subbaraman LN, Coles-Brennan C, Fadli Z, Jones LW. Biological and Clinical Implications of Lysozyme Deposition on Soft Contact Lenses. Optom Vis Sci 2015; 92:750-7. [PMID: 26002002 PMCID: PMC5638422 DOI: 10.1097/opx.0000000000000615] [Citation(s) in RCA: 56] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2014] [Accepted: 02/17/2015] [Indexed: 12/28/2022] Open
Abstract
Within a few minutes of wear, contact lenses become rapidly coated with a variety of tear film components, including proteins, lipids, and mucins. Tears have a rich and complex composition, allowing a wide range of interactions and competitive processes, with the first event observed at the interface between a contact lens and tear fluid being protein adsorption. Protein adsorption on hydrogel contact lenses is a complex process involving a variety of factors relating to both the protein in question and the lens material. Among tear proteins, lysozyme is a major protein that has both antibacterial and anti-inflammatory functions. Contact lens materials that have high ionicity and high water content have an increased affinity to accumulate lysozyme during wear, when compared with other soft lens materials, notably silicone hydrogel lenses. This review provides an overview of tear film proteins, with a specific focus on lysozyme, and examines various factors that influence protein deposition on contact lenses. In addition, the impact of lysozyme deposition on various ocular physiological responses and bacterial adhesion to lenses and the interaction of lysozyme with other tear proteins are reviewed. This comprehensive review suggests that deposition of lysozyme on contact lens materials may provide a number of beneficial effects during contact lens wear.
Collapse
|
20
|
|
21
|
Bhamla MS, Nash WL, Elliott S, Fuller GG. Influence of lipid coatings on surface wettability characteristics of silicone hydrogels. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2015; 31:3820-3828. [PMID: 25280206 DOI: 10.1021/la503437a] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Insoluble lipids serve vital functions in our bodies and interact with biomedical devices, e.g., the tear film on a contact lens. Over a period of time, these naturally occurring lipids form interfacial coatings that modify the wettability characteristics of these foreign synthetic surfaces. In this study, we examine the deposition and consequences of tear film lipids on silicone hydrogel (SiHy) contact lenses. We use bovine meibum, which is a complex mixture of waxy esters, cholesterol esters, and lipids that is secreted from the meibomian glands located on the upper and lower eyelids of mammals. For comparison, we study two commercially available model materials: dipalmitoylphosphatidylcholine (DPPC) and cholesterol. Upon deposition, we find that DPPC and meibum remain closer to the SiHy surface than cholesterol, which diffuses further into the porous SiHy matrix. In addition, we also monitor the fate of unstable thin liquid films that consequently rupture and dewet on these lipid-decorated surfaces. This dewetting provides valuable qualitative and quantitative information about the wetting characteristics of these SiHy substrates. We observe that decorating the SiHy surface with simple model lipids such as DPPC and cholesterol increases the hydrophilicity, which consequently inhibits dewetting, whereas meibum behaves conversely.
Collapse
Affiliation(s)
- M Saad Bhamla
- †Department of Chemical Engineering, Stanford University, Stanford, California 94305, United States
| | - Walter L Nash
- ‡Alcon Research Ltd., Fort Worth, Texas 76134, United States
| | - Stacey Elliott
- ‡Alcon Research Ltd., Fort Worth, Texas 76134, United States
| | - Gerald G Fuller
- †Department of Chemical Engineering, Stanford University, Stanford, California 94305, United States
| |
Collapse
|
22
|
Dursch TJ, Liu DE, Oh Y, Radke CJ. Fluorescent solute-partitioning characterization of layered soft contact lenses. Acta Biomater 2015; 15:48-54. [PMID: 25484335 DOI: 10.1016/j.actbio.2014.11.046] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2014] [Revised: 11/04/2014] [Accepted: 11/25/2014] [Indexed: 11/28/2022]
Abstract
Partitioning of aqueous packaging, wetting, and care-solution agents into and out of soft contact lenses (SCLs) is important for improving wear comfort and also for characterizing lens physico-chemical properties. We illustrate both features of partitioning by application of fluorescent-solute partitioning into DAILIES TOTAL1® (delefilcon A) water-gradient SCLs, which exhibit a layered structure of a silicone-hydrogel (SiHy) core sandwiched between thin surface-gel layers. Two-photon fluorescence confocal laser-scanning microscopy and attenuated total-reflectance Fourier-transform infrared spectroscopy (ATR-FTIR) characterize the lens and assess uptake profiles of six prototypical fluorescent solutes. Comparison of solute uptake in a SiHy-core prototype lens (i.e., O2OPTIX(TM)) validates the core SiHy structure of DAILIESTOTAL1®. To establish surface-layer charge, partition coefficients and water contents are obtained for aqueous pH values of 4 and 7.4. Solute fluorescence-intensity profiles clearly confirm a layered structure for the DAILIES TOTAL1® lenses. In all cases, aqueous solute partition coefficients are greater in the surface layers than in the SiHy core, signifying higher water in the surface gels. ATR-FTIR confirms surface-layer mass water contents of 82±3%. Water uptake and hydrophilic-solute uptake at pH 4 compared with that at pH 7.4 reveal that the surface-gel layers are anionic at physiologic pH 7.4, whereas both the SiHy core and O2OPTIX™ (lotrafilcon B) are nonionic. We successfully confirm the layered structure of DAILIES TOTAL1®, consisting of an 80-μm-thick SiHy core surrounded by 10-μm-thick polyelectrolyte surface-gel layers of significantly greater water content and aqueous solute uptake compared with the core. Accordingly, fluorescent-solute partitioning in SCLs provides information on gel structure and composition, in addition to quantifying uptake and release amounts and rates.
Collapse
Affiliation(s)
- T J Dursch
- Chemical and Biomolecular Engineering Department, University of California, 101E Gilman, Berkeley, CA 94720-1462, USA
| | - D E Liu
- Chemical and Biomolecular Engineering Department, University of California, 101E Gilman, Berkeley, CA 94720-1462, USA
| | - Y Oh
- Chemical and Biomolecular Engineering Department, University of California, 101E Gilman, Berkeley, CA 94720-1462, USA
| | - C J Radke
- Chemical and Biomolecular Engineering Department, University of California, 101E Gilman, Berkeley, CA 94720-1462, USA; Vision Science Group, University of California, Berkeley, CA 94720, USA.
| |
Collapse
|
23
|
Bhamla MS, Giacomin CE, Balemans C, Fuller GG. Influence of interfacial rheology on drainage from curved surfaces. SOFT MATTER 2014; 10:6917-25. [PMID: 25140576 DOI: 10.1039/c3sm52934g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Thin lubrication flows accompanying drainage from curved surfaces surround us (e.g., the drainage of the tear film on our eyes). These draining aqueous layers are normally covered with surface-active molecules that render the free surface viscoelastic. The non-Newtonian character of these surfaces fundamentally alters the dynamics of drainage. We show that increased film stability during drainage can occur as a consequence of enhanced surface rheology. Increasing the surfactant layer viscosity decreases the rate of drainage; however, this retarding influence is most pronounced when the insoluble surfactant layer has significant elasticity. We also present a simple theoretical model that offers qualitative support to our experimental findings.
Collapse
Affiliation(s)
- M Saad Bhamla
- Department of Chemical Engineering, Stanford University, Stanford, California 94305, USA.
| | | | | | | |
Collapse
|
24
|
Hall B, Jones L, Forrest JA. Kinetics of Competitive Adsorption between Lysozyme and Lactoferrin on Silicone Hydrogel Contact Lenses and the Effect on Lysozyme Activity. Curr Eye Res 2014; 40:622-31. [PMID: 25251834 DOI: 10.3109/02713683.2014.946518] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE To determine the effect of competitive adsorption between lysozyme and lactoferrin on silicone hydrogel contact lenses and the effect on lysozyme activity. METHODS Three commercially available silicone hydrogel contact lens materials (senofilcon A, lotrafilcon B and balafilcon A) were examined, for time points ranging from 10 s to 2 h. Total protein deposition was determined by I(125) radiolabeling of lysozyme and lactoferrin, while the activity of lysozyme was determined by a micrococcal activity assay. RESULTS Senofilcon A and balafilcon A did not show any relevant competitive adsorption between lysozyme and lactoferrin. Lotrafilcon B showed reduced protein deposition due to competitive adsorption for lactoferrin at all time points and lysozyme after 7.5 min. Co-adsorption of lactoferrin and lysozyme decreased the activity of lysozyme in solution for senofilcon A and lotrafilcon B, but co-adsorption had no effect on the surface activity of lysozyme for all lens types investigated. CONCLUSIONS Competition between lysozyme and lactoferrin is material specific. Co-adsorption of lysozyme and lactoferrin does not affect the activity of surface-bound lysozyme but can reduce the activity of subsequently desorbed lysozyme.
Collapse
Affiliation(s)
- Brad Hall
- Centre for Contact Lens Research, School of Optometry and Vision Science , Waterloo, Ontario , Canada and
| | | | | |
Collapse
|
25
|
|
26
|
|
27
|
Water-soluble drug partitioning and adsorption in HEMA/MAA hydrogels. Biomaterials 2014; 35:620-9. [DOI: 10.1016/j.biomaterials.2013.09.109] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2013] [Accepted: 09/26/2013] [Indexed: 11/20/2022]
|
28
|
Liu DE, Kotsmar C, Nguyen F, Sells T, Taylor NO, Prausnitz JM, Radke CJ. Macromolecule Sorption and Diffusion in HEMA/MAA Hydrogels. Ind Eng Chem Res 2013. [DOI: 10.1021/ie402148u] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- D. E. Liu
- Department
of Chemical and Biomolecular Engineering and ‡Vision Science Group, University of California, Berkeley, Berkeley, California, 94720-1462, United States
| | - C. Kotsmar
- Department
of Chemical and Biomolecular Engineering and ‡Vision Science Group, University of California, Berkeley, Berkeley, California, 94720-1462, United States
| | - F. Nguyen
- Department
of Chemical and Biomolecular Engineering and ‡Vision Science Group, University of California, Berkeley, Berkeley, California, 94720-1462, United States
| | - T. Sells
- Department
of Chemical and Biomolecular Engineering and ‡Vision Science Group, University of California, Berkeley, Berkeley, California, 94720-1462, United States
| | - N. O. Taylor
- Department
of Chemical and Biomolecular Engineering and ‡Vision Science Group, University of California, Berkeley, Berkeley, California, 94720-1462, United States
| | - J. M. Prausnitz
- Department
of Chemical and Biomolecular Engineering and ‡Vision Science Group, University of California, Berkeley, Berkeley, California, 94720-1462, United States
| | - C. J. Radke
- Department
of Chemical and Biomolecular Engineering and ‡Vision Science Group, University of California, Berkeley, Berkeley, California, 94720-1462, United States
| |
Collapse
|
29
|
|
30
|
Material properties that predict preservative uptake for silicone hydrogel contact lenses. Eye Contact Lens 2013; 38:350-7. [PMID: 23085619 DOI: 10.1097/icl.0b013e318272c470] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To assess material properties that affect preservative uptake by silicone hydrogel lenses. METHODS We evaluated the water content (using differential scanning calorimetry), effective pore size (using probe penetration), and preservative uptake (using high-performance liquid chromatography with spectrophotometric detection) of silicone and conventional hydrogel soft contact lenses. RESULTS Lenses grouped similarly based on freezable water content as they did based on total water content. Evaluation of the effective pore size highlighted potential differences between the surface-treated and non-surface-treated materials. The water content of the lens materials and ionic charge are associated with the degree of preservative uptake. CONCLUSIONS The current grouping system for testing contact lens-solution interactions separates all silicone hydrogels from conventional hydrogel contact lenses. However, not all silicone hydrogel lenses interact similarly with the same contact lens solution. Based upon the results of our research, we propose that the same material characteristics used to group conventional hydrogel lenses, water content and ionic charge, can also be used to predict uptake of hydrophilic preservatives for silicone hydrogel lenses. In addition, the hydrophobicity of silicone hydrogel contact lenses, although not investigated here, is a unique contact lens material property that should be evaluated for the uptake of relatively hydrophobic preservatives and tear components.
Collapse
|
31
|
Ng A, Heynen M, Luensmann D, Subbaraman LN, Jones L. Impact of tear film components on the conformational state of lysozyme deposited on contact lenses. J Biomed Mater Res B Appl Biomater 2013; 101:1172-81. [PMID: 23564739 DOI: 10.1002/jbm.b.32927] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2012] [Revised: 12/06/2012] [Accepted: 01/30/2013] [Indexed: 11/07/2022]
Affiliation(s)
- Alan Ng
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| | - Miriam Heynen
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| | - Doerte Luensmann
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| | - Lakshman N. Subbaraman
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| | - Lyndon Jones
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| |
Collapse
|
32
|
Kotsmar C, Sells T, Taylor N, Liu DE, Prausnitz JM, Radke CJ. Aqueous Solute Partitioning and Mesh Size in HEMA/MAA Hydrogels. Macromolecules 2012. [DOI: 10.1021/ma3018487] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Csaba Kotsmar
- Department
of Chemical and Biomolecular
Engineering, University of California, Berkeley, Berkeley, California 94720, United States
| | - Teresa Sells
- Department
of Chemical and Biomolecular
Engineering, University of California, Berkeley, Berkeley, California 94720, United States
| | - Nicole Taylor
- Department
of Chemical and Biomolecular
Engineering, University of California, Berkeley, Berkeley, California 94720, United States
| | - David E. Liu
- Department
of Chemical and Biomolecular
Engineering, University of California, Berkeley, Berkeley, California 94720, United States
| | - J. M. Prausnitz
- Department
of Chemical and Biomolecular
Engineering, University of California, Berkeley, Berkeley, California 94720, United States
| | - C. J. Radke
- Department
of Chemical and Biomolecular
Engineering, University of California, Berkeley, Berkeley, California 94720, United States
- Vision Science Group, University of California, Berkeley, Berkeley, California
94720, United States
| |
Collapse
|
33
|
|
34
|
Hall B, Jones L, Forrest JA. Measuring the kinetics and activity of adsorbed proteins:In vitrolysozyme deposited onto hydrogel contact lenses over short time periods. J Biomed Mater Res A 2012; 101:755-64. [DOI: 10.1002/jbm.a.34357] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2011] [Revised: 06/05/2012] [Accepted: 06/20/2012] [Indexed: 11/11/2022]
|
35
|
Weeks A, Boone A, Luensmann D, Jones L, Sheardown H. The effects of hyaluronic acid incorporated as a wetting agent on lysozyme denaturation in model contact lens materials. J Biomater Appl 2012; 28:323-33. [PMID: 22561981 DOI: 10.1177/0885328212446936] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Conventional and silicone hydrogels as models for contact lenses were prepared to determine the effect of the presence of hyaluronic acid on lysozyme sorption and denaturation. Hyaluronic acid was loaded into poly(2-hydroxyethyl methacrylate) and poly(2-hydroxyethyl methacrylate)/TRIS--methacryloxypropyltris (trimethylsiloxy silane) hydrogels, which served as models for conventional and silicone hydrogel contact lens materials. The hyaluronic acid was cross-linked using 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide in the presence of dendrimers. Active lysozyme was quantified using a Micrococcus lysodeikticus assay while total lysozyme was determined using 125-I radiolabeled protein. To examine the location of hyaluronic acid in the gels, 6-aminofluorescein labeled hyaluronic acid was incorporated into the gels using 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide chemistry and the gels were examined using confocal laser scanning microscopy. Hyaluronic acid incorporation significantly reduced lysozyme sorption in poly(2-hydroxyethyl methacrylate) (p < 0.00001) and poly(2-hydroxyethyl methacrylate)/TRIS--methacryloxypropyltris (trimethylsiloxy silane) (p < 0.001) hydrogels, with the modified materials sorbing only 20% and 16% that of the control, respectively. More importantly, hyaluronic acid also decreased lysozyme denaturation in poly(2-hydroxyethyl methacrylate) (p < 0.005) and poly(2-hydroxyethyl methacrylate)/TRIS--methacryloxypropyltris (trimethylsiloxy silane) (p < 0.02) hydrogels. The confocal laser scanning microscopy results showed that the hyaluronic acid distribution was dependent on both the material type and the molecular weight of hyaluronic acid. This study demonstrates that hyaluronic acid incorporated as a wetting agent has the potential to reduce lysozyme sorption and denaturation in contact lens applications. The distribution of hyaluronic acid within hydrogels appears to affect denaturation, with more surface mobile, lower molecular weight hyaluronic acid being more effective in preventing denaturation.
Collapse
Affiliation(s)
- Andrea Weeks
- School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada
| | | | | | | | | |
Collapse
|
36
|
Protein deposition on contact lenses: The past, the present, and the future. Cont Lens Anterior Eye 2012; 35:53-64. [DOI: 10.1016/j.clae.2011.12.005] [Citation(s) in RCA: 119] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2010] [Revised: 12/18/2011] [Accepted: 12/24/2011] [Indexed: 11/19/2022]
|
37
|
Omali NB, Zhao Z, Zhong L, Raftery MJ, Zhu H, Ozkan J, Willcox M. Quantification of protein deposits on silicone hydrogel materials using stable-isotopic labeling and multiple reaction monitoring. BIOFOULING 2012; 28:697-709. [PMID: 22784025 DOI: 10.1080/08927014.2012.702763] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
This study was designed to use multiple reaction monitoring (MRM) for accurate quantification of contact lens protein deposits. Worn lenses used with a multipurpose disinfecting solution were collected after wear. Individual contact lenses were extracted and then digested with trypsin. MRM in conjunction with stable-isotope-labeled peptide standards was used for protein quantification. The results show that lysozyme was the major protein detected from both lens types. The amount of protein extracted from contact lenses was affected by the lens material. Except for keratin-1 (0.83 ± 0.61 vs 0.77 ± 0.20, p = 0.81) or proline rich protein-4 (0.11 ± 0.04 vs 0.15 ± 0.12, p = 0.97), the amounts of lysozyme, lactoferrin, or lipocalin-1 extracted from balafilcon A lenses (12.9 ± 9.01, 0.84 ± 0.50 or 2.06 ± 1.6, respectively) were significantly higher than that extracted from senofilcon A lenses (0.88 ± 0.13, 0.50 ± 0.10 or 0.27 ± 0.23, respectively) (p < 0.05). The amount of protein extracted from contact lenses was dependent on both the individual wearer and the contact lens material. This may have implications for the development of clinical responses during lens wear for different people and with different types of contact lenses. The use of MRM-MS is a powerful analytical tool for the quantification of specific proteins from single contact lenses after wear.
Collapse
|
38
|
Weeks A, Luensmann D, Boone A, Jones L, Sheardown H. Hyaluronic acid as an internal wetting agent in model DMAA/TRIS contact lenses. J Biomater Appl 2011; 27:423-32. [DOI: 10.1177/0885328211410999] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Model silicone hydrogel contact lenses, comprised of N,N-dimethylacrylamide and methacryloxypropyltris (trimethylsiloxy) silane, were fabricated and hyaluronic acid (HA) was incorporated as an internal wetting agent using a dendrimer-based method. HA and dendrimers were loaded into the silicone hydrogels and cross-linked using 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide chemistry. The presence and location of HA in the hydrogels was confirmed using X-ray photoelectron spectroscopy and confocal laser scanning microscopy, respectively. The effects of the presence of HA on the silicone hydrogels on hydrophilicity, swelling behavior, transparency, and lysozyme sorption and denaturation were evaluated. The results showed that HA increased the hydrophilicity and the equilibrium water content of the hydrogels without affecting transparency. HA also significantly decreased the amount of lysozyme sorption ( p < 0.002). HA had no effect on lysozyme denaturation in hydrogels containing 0% and 1.7% methacrylic acid (MAA) (by weight) but when the amount of MAA was increased to 5%, the level of lysozyme denaturation was significantly lower compared to control materials. These results suggest that HA has great potential to be used as a wetting agent in silicone hydrogel contact lenses to improve wettability and to decrease lysozyme sorption and denaturation.
Collapse
Affiliation(s)
- Andrea Weeks
- School of Biomedical Engineering, McMaster University, Hamilton ON Canada
| | | | - Adrienne Boone
- School of Optometry, University of Waterloo, Waterloo ON Canada
| | - Lyndon Jones
- School of Biomedical Engineering, McMaster University, Hamilton ON Canada
- School of Optometry, University of Waterloo, Waterloo ON Canada
- Department of Chemical Engineering, McMaster University, Hamilton ON Canada
| | - Heather Sheardown
- School of Biomedical Engineering, McMaster University, Hamilton ON Canada
- School of Optometry, University of Waterloo, Waterloo ON Canada
- Department of Chemical Engineering, McMaster University, Hamilton ON Canada
| |
Collapse
|
39
|
|
40
|
Luensmann D, Jones L. Impact of fluorescent probes on albumin sorption profiles to ophthalmic biomaterials. J Biomed Mater Res B Appl Biomater 2010; 94:327-336. [PMID: 20574970 DOI: 10.1002/jbm.b.31655] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Bovine serum albumin (BSA) was conjugated to three organic fluorescent probes, 5-(4,6-dichloro-s-triazin-2-ylamino)fluorescein hydrochloride (DTAF), Rhodamine B isothiocyanate (RITC), and Lucifer yellow VS (LY). The protein sorption profile to one pHEMA-based (etafilcon A) and three silicone hydrogel (SH) contact lens types (lotrafilcon B, balafilcon A and senofilcon A) was determined using confocal laser scanning microscopy. In addition, all lenses were incubated in dye solutions containing the fluorescent probe alone; and in a separate experiment BSA accumulation was quantified using radiolabeling. The different fluorescent conjugates showed similar sorption profiles for the pHEMA-based lens, but marked differences for all SH lenses. Lotrafilcon B accumulated more protein on the surface as compared to the matrix, independent of the fluorescent probe used for conjugation. Protein sorption varied for senofilcon A, with DTAF-BSA sorbing primarily to the surface region, while the other conjugates penetrated in equal amounts into the matrix. Balafilcon A exhibited smaller differences between conjugates, with LY-BSA allowing the protein to fully penetrate the matrix, while the other conjugates showed minor surface adsorption. Sorption curves of unbound dyes were often similar compared to the conjugated results. BSA profiles to pHEMA-based and silicone hydrogel lenses were highly dependent on the fluorescent probe used and none of the probes accurately reflected quantitative protein levels for the lens materials investigated.
Collapse
Affiliation(s)
- Doerte Luensmann
- School of Optometry, Centre for Contact Lens Research, University of Waterloo, Waterloo, Ontario N2L3G1, Canada.
| | | |
Collapse
|
41
|
|