Zhang G, Liu X, Wang L, Zhu J, Yu J. Development and feasibility evaluation of an AR-assisted radiotherapy positioning system. Front Oncol 2022; 12:921607. [PMID: 36267969 PMCID: PMC9577500 DOI: 10.3389/fonc.2022.921607] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2022] [Accepted: 09/13/2022] [Indexed: 11/28/2022] Open
Abstract
Purpose The aim of this study is to develop an augmented reality (AR)–assisted radiotherapy positioning system based on HoloLens 2 and to evaluate the feasibility and accuracy of this method in the clinical environment. Methods The obtained simulated computed tomography (CT) images of an “ISO cube”, a cube phantom, and an anthropomorphic phantom were reconstructed into three-dimensional models and imported into the HoloLens 2. On the basis of the Vuforia marker attached to the “ISO cube” placed at the isocentric position of the linear accelerator, the correlation between the virtual and real space was established. First, the optimal conditions to minimize the deviation between virtual and real objects were explored under different conditions with a cube phantom. Then, the anthropomorphic phantom–based positioning was tested under the optimal conditions, and the positioning errors were evaluated with cone-beam CT. Results Under the normal light intensity, the registration and tracking angles are 0°, the distance is 40 cm, and the deviation reached a minimum of 1.4 ± 0.3 mm. The program would not run without light. The hologram drift caused by the light change, camera occlusion, and head movement were 0.9 ± 0.7 mm, 1.0 ± 0.6 mm, and 1.5 ± 0.9 mm, respectively. The anthropomorphic phantom–based positioning errors were 3.1 ± 1.9 mm, 2.4 ± 2.5 mm, and 4.6 ± 2.8 mm in the X (lateral), Y (vertical), and Z (longitudinal) axes, respectively, and the angle deviation of Rtn was 0.26 ± 0.14°. Conclusion The AR-assisted radiotherapy positioning based on HoloLens 2 is a feasible method with certain advantages, such as intuitive visual guidance, radiation-free position verification, and intelligent interaction. Hardware and software upgrades are expected to further improve accuracy and meet clinicalbrendaannmae requirements.
Collapse
Affiliation(s)
- Gongsen Zhang
- 1Department of Radiology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China
| | - Xinchao Liu
- Cancer Center, Shandong University, Jinan, China
| | - Linlin Wang
- 1Department of Radiology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China
- Cancer Center, Shandong University, Jinan, China
- *Correspondence: Linlin Wang, ; Jinming Yu,
| | - Jian Zhu
- 1Department of Radiology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China
| | - Jinming Yu
- 1Department of Radiology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China
- *Correspondence: Linlin Wang, ; Jinming Yu,
| |
Collapse
|
2
|
Zhu J, Su Y, Liu Z, Liu B, Sun Y, Gao W, Fu Y. Real‐time biomechanical modelling of the liver using LightGBM model. Int J Med Robot 2022; 18:e2433. [DOI: 10.1002/rcs.2433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 05/19/2022] [Accepted: 06/04/2022] [Indexed: 11/05/2022]
Affiliation(s)
- Jiahua Zhu
- State Key Laboratory of Robotics and System School of Life Science and Technology Harbin Institute of Technology Harbin China
| | - Yixian Su
- State Key Laboratory of Robotics and System School of Life Science and Technology Harbin Institute of Technology Harbin China
| | - Ziteng Liu
- State Key Laboratory of Robotics and System School of Life Science and Technology Harbin Institute of Technology Harbin China
| | - Bainan Liu
- State Key Laboratory of Robotics and System School of Life Science and Technology Harbin Institute of Technology Harbin China
| | - Yu Sun
- State Key Laboratory of Robotics and System School of Life Science and Technology Harbin Institute of Technology Harbin China
| | - Wenpeng Gao
- State Key Laboratory of Robotics and System School of Life Science and Technology Harbin Institute of Technology Harbin China
| | - Yili Fu
- State Key Laboratory of Robotics and System School of Life Science and Technology Harbin Institute of Technology Harbin China
| |
Collapse
|
3
|
Xu H, Gong G, Yin Y, Liu T. A preliminary investigation of re-evaluating the irradiation dose in hepatocellular carcinoma radiotherapy applying 4D CT and deformable registration. J Appl Clin Med Phys 2021; 22:13-20. [PMID: 33452706 PMCID: PMC7882094 DOI: 10.1002/acm2.13111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 10/26/2020] [Accepted: 11/11/2020] [Indexed: 11/21/2022] Open
Abstract
Purpose To investigate the effect of breathing motion on dose distribution for hepatocellular carcinoma (HCC) patients using four‐dimensional (4D) CT and deformable registration. Methods Fifty HCC patients who were going to receive radiotherapy were enrolled in this study. All patients had been treated with transarterial chemoembolization beforehand. Three‐dimensional (3D) and 4D CT scans in free breathing were acquired sequentially. Volumetric modulated arc therapy (VMAT) was planned on the 3D CT images and maximum intensity projection (MIP) images. Thus, the 3D dose (Dose‐3D) and MIP dose (Dose‐MIP) were obtained, respectively. Then, the Dose‐3D and Dose‐MIP were recalculated on 10 phases of 4D CT images, respectively, in which the end‐inhale and end‐exhale phase doses were defined as Dose‐3D‐EI, Dose‐3D‐EE, Dose‐MIP‐EI, and Dose‐MIP‐EE. The 4D dose (Dose‐4D‐3D and Dose‐4D‐MIP) were obtained by deforming 10 phase doses to the end‐exhale CT to accumulate. The dosimetric difference in Dose‐3D, Dose‐EI3D, Dose‐EE3D, Dose‐4D‐3D, Dose‐MIP, Dose‐EIMIP, Dose‐EEMIP, and Dose‐4D‐MIP were compared to evaluate the motion effect on dose delivery to the planning target volume (PTV) and normal liver. Results Compared with Dose‐3D, PTV D99 in Dose‐EI3D, Dose‐EE3D and Dose‐4D‐3D decreased by an average of 6.02%, 1.32%, 2.43%, respectively (P < 0.05); while PTV D95 decreased by an average of 3.34%, 1.51%, 1.93%, respectively (P < 0.05). However, CI and HI of the PTV in Dose‐3D was superior to the other three distributions (P < 0.05). There was no significant differences for the PTV between Dose‐EI and Dose‐EE, and between the two extreme phase doses and Dose‐4D (P> 0.05). Negligible difference was observed for normal liver in all dose distributions (P> 0.05). Conclusions Four‐dimensional dose calculations potentially ensure target volume coverage when breathing motion may affect the dose distribution. Dose escalation can be considered to improve the local control of HCC on the basis of accurately predicting the probability of radiation‐induced liver disease.
Collapse
Affiliation(s)
- Hua Xu
- The Second People's Hospital of Liaocheng, The Second Hospital of Liaocheng Affiliated to Shandong First Medical University, Shandong, China
| | - Guanzhong Gong
- Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Shandong, China
| | - Yong Yin
- Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Shandong, China
| | - Tonghai Liu
- Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Shandong, China
| |
Collapse
|
4
|
Synthetic CT in assessment of anatomical and dosimetric variations in radiotherapy - procedure validation. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING 2020. [DOI: 10.2478/pjmpe-2020-0022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Abstract
Introduction: One of many procedures to control the quality of radiotherapy is daily imaging of the patient’s anatomy. The CBCT (Cone Beam Computed Tomography) plays an important role in patient positioning, and dose delivery monitoring. Nowadays, CBCT is a baseline for the calculation of fraction and total dose. Thus, it provides the potential for more comprehensive monitoring of the delivered dose and adaptive radiotherapy. However, due to the poor quality and the presence of numerous artifacts, the replacement of the CBCT image with the corrected one is desired for dose calculation. The aim of the study was to validate a method for generating a synthetic CT image based on deformable image registration.
Material and methods: A Head & Torso Freepoint phantom, model 002H9K (Computerized Imaging Reference Systems, Norfolk, USA) with inserts was imaged with CT (Computed Tomography). Then, contouring and treatment plan were created in Eclipse (Varian Medical Systems, Palo Alto, CA, USA) treatment planning system. The phantom was scanned again with the CBCT. The planning CT was registered and deformed to the CBCT, resulting in a synthetic CT in Velocity software (Varian Medical Systems, Palo Alto, CA, USA). The dose distribution was recalculated based on the created CT image.
Results: Differences in structure volumes and dose statistics calculated both on CT and synthetic CT were evaluated. Discrepancies between the original and delivered plan from 0.0 to 2.5% were obtained. Dose comparison was performed on the DVH (Dose-Volume Histogram) for all delineated inserts.
Conclusions: Our findings suggest the potential utility of deformable registration and synthetic CT for providing dose reconstruction. This study reports on the limitation of the procedure related to the limited length of the CBCT volume and deformable fusion inaccuracies.
Collapse
|
5
|
Cazoulat G, Elganainy D, Anderson BM, Zaid M, Park PC, Koay EJ, Brock KK. Vasculature-Driven Biomechanical Deformable Image Registration of Longitudinal Liver Cholangiocarcinoma Computed Tomographic Scans. Adv Radiat Oncol 2020; 5:269-278. [PMID: 32280827 PMCID: PMC7136628 DOI: 10.1016/j.adro.2019.10.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Revised: 09/22/2019] [Accepted: 10/10/2019] [Indexed: 11/28/2022] Open
Abstract
PURPOSE Deformable image registration (DIR) of longitudinal liver cancer computed tomographic (CT) images can be challenging owing to anatomic changes caused by radiation therapy (RT) or disease progression. We propose a workflow for the DIR of longitudinal contrast-enhanced CT scans of liver cancer based on a biomechanical model of the liver driven by boundary conditions on the liver surface and centerline of an autosegmentation of the vasculature. METHODS AND MATERIALS Pre- and post-RT CT scans acquired with a median gap of 112 (32-217) days for 28 patients who underwent RT for intrahepatic cholangiocarcinoma were retrospectively analyzed. For each patient, 5 corresponding anatomic landmarks in pre- and post-RT scans were identified in the liver by a clinical expert for evaluation of the accuracy of different DIR strategies. The first strategy corresponded to the use of a biomechanical model-based DIR method with boundary conditions specified on the liver surface (BM_DIR). The second strategy corresponded to the use of an expansion of BM_DIR consisting of the auto-segmentation of the liver vasculature to determine additional boundary conditions in the biomechanical model (BM_DIR_VBC). The 2 strategies were also compared with an intensity-based DIR strategy using a Demons algorithms. RESULTS The group mean target registration errors were 12.4 ± 7.5, 7.7 ± 3.7 and 4.4 ± 2.5 mm, for the Demons, BM_DIR and BM_DIR_VBC, respectively. CONCLUSIONS In regard to the large and complex deformation observed in this study and the achieved accuracy of 4.4 mm, the proposed BM_DIR_VBC method might reveal itself as a valuable tool in future studies on the relationship between delivered dose and treatment outcome.
Collapse
Affiliation(s)
- Guillaume Cazoulat
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Dalia Elganainy
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Brian M. Anderson
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Mohamed Zaid
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Peter C. Park
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Eugene J. Koay
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Kristy K. Brock
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas
| |
Collapse
|
6
|
Rigaud B, Simon A, Castelli J, Lafond C, Acosta O, Haigron P, Cazoulat G, de Crevoisier R. Deformable image registration for radiation therapy: principle, methods, applications and evaluation. Acta Oncol 2019; 58:1225-1237. [PMID: 31155990 DOI: 10.1080/0284186x.2019.1620331] [Citation(s) in RCA: 60] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Background: Deformable image registration (DIR) is increasingly used in the field of radiation therapy (RT) to account for anatomical deformations. The aims of this paper are to describe the main applications of DIR in RT and discuss current DIR evaluation methods. Methods: Articles on DIR published from January 2000 to October 2018 were extracted from PubMed and Science Direct. Our search was restricted to articles that report data obtained from humans, were written in English, and address DIR methods for RT. A total of 207 articles were selected from among 2506 identified in the search process. Results: At planning, DIR is used for organ delineation using atlas-based segmentation, deformation-based planning target volume definition, functional planning and magnetic resonance imaging-based dose calculation. In image-guided RT, DIR is used for contour propagation and dose calculation on per-treatment imaging. DIR is also used to determine the accumulated dose from fraction to fraction in external beam RT and brachytherapy, both for dose reporting and adaptive RT. In the case of re-irradiation, DIR can be used to estimate the cumulated dose of the two irradiations. Finally, DIR can be used to predict toxicity in voxel-wise population analysis. However, the evaluation of DIR remains an open issue, especially when dealing with complex cases such as the disappearance of matter. To quantify DIR uncertainties, most evaluation methods are limited to geometry-based metrics. Software companies have now integrated DIR tools into treatment planning systems for clinical use, such as contour propagation and fraction dose accumulation. Conclusions: DIR is increasingly important in RT applications, from planning to toxicity prediction. DIR is routinely used to reduce the workload of contour propagation. However, its use for complex dosimetric applications must be carefully evaluated by combining quantitative and qualitative analyses.
Collapse
Affiliation(s)
- Bastien Rigaud
- CLCC Eugène Marquis, University of Rennes, Inserm , Rennes , France
| | - Antoine Simon
- CLCC Eugène Marquis, University of Rennes, Inserm , Rennes , France
| | - Joël Castelli
- CLCC Eugène Marquis, University of Rennes, Inserm , Rennes , France
| | - Caroline Lafond
- CLCC Eugène Marquis, University of Rennes, Inserm , Rennes , France
| | - Oscar Acosta
- CLCC Eugène Marquis, University of Rennes, Inserm , Rennes , France
| | - Pascal Haigron
- CLCC Eugène Marquis, University of Rennes, Inserm , Rennes , France
| | - Guillaume Cazoulat
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center , Houston , TX , USA
| | | |
Collapse
|
7
|
Papież BW, Franklin JM, Heinrich MP, Gleeson FV, Brady M, Schnabel JA. GIFTed Demons: deformable image registration with local structure-preserving regularization using supervoxels for liver applications. J Med Imaging (Bellingham) 2018; 5:024001. [PMID: 29662918 PMCID: PMC5886381 DOI: 10.1117/1.jmi.5.2.024001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Accepted: 03/13/2018] [Indexed: 11/14/2022] Open
Abstract
Deformable image registration, a key component of motion correction in medical imaging, needs to be efficient and provides plausible spatial transformations that reliably approximate biological aspects of complex human organ motion. Standard approaches, such as Demons registration, mostly use Gaussian regularization for organ motion, which, though computationally efficient, rule out their application to intrinsically more complex organ motions, such as sliding interfaces. We propose regularization of motion based on supervoxels, which provides an integrated discontinuity preserving prior for motions, such as sliding. More precisely, we replace Gaussian smoothing by fast, structure-preserving, guided filtering to provide efficient, locally adaptive regularization of the estimated displacement field. We illustrate the approach by applying it to estimate sliding motions at lung and liver interfaces on challenging four-dimensional computed tomography (CT) and dynamic contrast-enhanced magnetic resonance imaging datasets. The results show that guided filter-based regularization improves the accuracy of lung and liver motion correction as compared to Gaussian smoothing. Furthermore, our framework achieves state-of-the-art results on a publicly available CT liver dataset.
Collapse
Affiliation(s)
- Bartłomiej W Papież
- University of Oxford, Institute of Biomedical Engineering, Department of Engineering Science, Oxford, United Kingdom
| | - James M Franklin
- University of Oxford, Department of Oncology, Oxford, United Kingdom
| | | | - Fergus V Gleeson
- Oxford University Hospitals NHS Trust, Churchill Hospital, Department of Radiology, Oxford, United Kingdom
| | - Michael Brady
- University of Oxford, Department of Oncology, Oxford, United Kingdom
| | - Julia A Schnabel
- University of Oxford, Institute of Biomedical Engineering, Department of Engineering Science, Oxford, United Kingdom.,King's College London, School of Biomedical Engineering and Imaging Sciences, London, United Kingdom
| |
Collapse
|
8
|
Chen J, Murray L, Dawson LA, Velec M. The rolling stones: An inappropriate surrogate for upper-abdominal image-guided radiation therapy. Pract Radiat Oncol 2018; 8:369-372. [PMID: 29706303 DOI: 10.1016/j.prro.2018.03.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2018] [Accepted: 03/27/2018] [Indexed: 11/25/2022]
Affiliation(s)
- Jasmine Chen
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON, Canada
| | - Louise Murray
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON, Canada; Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada
| | - Laura A Dawson
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON, Canada; Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada
| | - Michael Velec
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON, Canada; Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada.
| |
Collapse
|
9
|
Solbiati M, Passera KM, Goldberg SN, Rotilio A, Ierace T, Pedicini V, Poretti D, Solbiati L. A Novel CT to Cone-Beam CT Registration Method Enables Immediate Real-Time Intraprocedural Three-Dimensional Assessment of Ablative Treatments of Liver Malignancies. Cardiovasc Intervent Radiol 2018; 41:1049-1057. [PMID: 29492634 PMCID: PMC5976710 DOI: 10.1007/s00270-018-1909-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2017] [Accepted: 02/17/2018] [Indexed: 12/19/2022]
Abstract
Aim To evaluate a novel contrast-enhanced cone-beam computed tomography (CE-CBCT) registration method for accurate immediate assessment of ablation outcomes. Materials and Methods Contrast-enhanced computed tomography (CECT) was registered with CE-CBCT by applying semiautomatic landmark registration followed by automatic affine and non-rigid registration to correct for respiratory phase differences and liver deformation. This scheme was retrospectively applied to 30 patients who underwent 38 percutaneous microwave liver ablations. Three datasets were obtained for each case: (1) conventional CECT scans 24 h before ablation, (2) intraprocedural CE-CBCT scans, and (3) CECT scans 24 h post-ablation. Using a five-point scale, two experienced radiologists qualitatively assessed registration quality, equivalence of CE-CBCT assessment of ablation outcome to 24 h post-ablation CECT, and perceived increase of confidence using the fusion method to CBCT alone. Additionally, residual post-ablation tumor volumes were measured at both CE-CBCT and 24 h CECT and compared to the pre-CECT. Results Registration quality was high for both radiologists (R1: 4.3 ± 0.6, R2: 4.4 ± 0.5; p = 0.87). Comparisons between the registration of pre-ablation CECT with CE-CBCT versus post-ablation CECT regarding the position of the ablated area to the treated target (R1: 4.4 ± 0.6, R2: 4.6 ± 0.4) and treatment outcome (R1: 4.5 ± 0.5, R2: 4.6 ± 0.4) were equivalent (p > 0.35). Increased confidence was noted when using fusion (R1: 4.6 ± 0.4, R2: 4.6 ± 0.4; p = 0.84). Moreover, in 6 ablations (15.8%) the intraprocedural registered CBCT showed residual tumor precisely where identified on the 24 h post-ablation CECT. Conclusions Combined CE-CBCT holds the potential to change the current workflow of mini-invasive cancer local treatments. Given earlier visual identification of residual tumor post-ablation, this includes potentially eliminating the need for some additional treatments.
Collapse
Affiliation(s)
| | | | - S Nahum Goldberg
- Department of Radiology, Hadassah Hebrew University Medical Centre, Jerusalem, Israel.,Department of Radiology, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | | | - Tiziana Ierace
- Department of Radiology, Humanitas Clinical and Research Center, Rozzano, Milan, Italy
| | - Vittorio Pedicini
- Department of Radiology, Humanitas Clinical and Research Center, Rozzano, Milan, Italy
| | - Dario Poretti
- Department of Radiology, Humanitas Clinical and Research Center, Rozzano, Milan, Italy
| | - Luigi Solbiati
- Department of Radiology, Humanitas Clinical and Research Center, Rozzano, Milan, Italy.,Department of Biomedical Sciences, Humanitas University, Rozzano, Milan, Italy
| |
Collapse
|
10
|
The status of augmented reality in laparoscopic surgery as of 2016. Med Image Anal 2017; 37:66-90. [DOI: 10.1016/j.media.2017.01.007] [Citation(s) in RCA: 183] [Impact Index Per Article: 26.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2016] [Revised: 01/16/2017] [Accepted: 01/23/2017] [Indexed: 12/27/2022]
|
11
|
Murray LJ, Dawson LA. Advances in Stereotactic Body Radiation Therapy for Hepatocellular Carcinoma. Semin Radiat Oncol 2017; 27:247-255. [PMID: 28577832 DOI: 10.1016/j.semradonc.2017.02.002] [Citation(s) in RCA: 64] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Stereotactic Body Radiation Therapy (SBRT) is an emerging effective treatment for hepatocellular carcinoma (HCC) associated with acceptable rates of toxicity in appropriately selected patients. Despite often being reserved for patients unsuitable for other local treatments, prospective and retrospective studies have demonstrated excellent long-term control. SBRT may be used as a stand-alone treatment, or as an adjunct to other HCC therapies. Based on available data, SBRT appears to complement existing local liver therapies. Randomized and nonrandomized comparative studies are required to better determine the optimal role of SBRT in HCC treatment.
Collapse
Affiliation(s)
- Louise J Murray
- Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada; Radiation Medicine Program, Princess Margaret Cancer Centre, University Health Network, Toronto, ON, Canada
| | - Laura A Dawson
- Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada; Radiation Medicine Program, Princess Margaret Cancer Centre, University Health Network, Toronto, ON, Canada.
| |
Collapse
|
12
|
Hu Y, Zhou YK, Chen YX, Zeng ZC. Magnitude and influencing factors of respiration-induced liver motion during abdominal compression in patients with intrahepatic tumors. Radiat Oncol 2017; 12:9. [PMID: 28073377 PMCID: PMC5223487 DOI: 10.1186/s13014-016-0762-z] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2016] [Accepted: 12/30/2016] [Indexed: 12/26/2022] Open
Abstract
PURPOSE The purpose of this study was to use 4-dimensional-computed tomography (4D-CT) to evaluate respiration-induced liver motion magnitude and influencing factors in patients with intrahepatic tumors undergoing abdominal compression. METHODS From January 2012 to April 2016, 99 patients with intrahepatic tumors were included in this study. They all underwent 4D-CT to assess respiratory liver motion. This was performed during abdominal compression in 53 patients and during free-breathing (no abdominal compression) in 46 patients. We defined abdominal compression as being effective in managing the breath amplitude if respiration-induced liver motion in the cranial-caudal (CC) direction during compression was ≤5 mm and as being ineffective if >5 mm of motion was observed. Gender, age, body mass index (BMI), transarterial chemoembolization history, liver resection history, tumor area, tumor number, and tumor size (diameter) were determined. Multivariate logistic regression analysis was used to analyze influencing factors associated with a breath amplitude ≤5 mm in the CC direction. RESULTS The mean respiration-induced liver motion during abdominal compression in the left-right (LR), CC, anterior-posterior (AP), and 3-dimensional vector directions was 2.9 ± 1.2 mm, 5.3 ± 2.2 mm, 2.3 ± 1.1 mm and 6.7 ± 2.1 mm, respectively. Univariate analysis indicated that gender and BMI significantly affected abdominal compression effectiveness (both p < 0.05). Multivariate analysis confirmed these two factors as significant predictors of effective abdominal compression: gender (p = 0.030) and BMI (p = 0.006). There was a strong correlation between gender and compression effectiveness (odds ratio [OR] = 7.450) and an even stronger correlation between BMI and compression effectiveness (OR = 10.842). CONCLUSIONS The magnitude of respiration-induced liver motion of patients with intrahepatic carcinoma undergoing abdominal compression is affected by gender and BMI, with abdominal compression being less effective in men and overweight patients.
Collapse
Affiliation(s)
- Yong Hu
- Department of Radiation Oncology, Zhongshan Hospital, Fudan University, 180, Feng Lin Road, Shanghai, 200032 China
| | - Yong-Kang Zhou
- Department of Radiation Oncology, Zhongshan Hospital, Fudan University, 180, Feng Lin Road, Shanghai, 200032 China
| | - Yi-Xing Chen
- Department of Radiation Oncology, Zhongshan Hospital, Fudan University, 180, Feng Lin Road, Shanghai, 200032 China
| | - Zhao-Chong Zeng
- Department of Radiation Oncology, Zhongshan Hospital, Fudan University, 180, Feng Lin Road, Shanghai, 200032 China
| |
Collapse
|
13
|
König L, Derksen A, Papenberg N, Haas B. Deformable image registration for adaptive radiotherapy with guaranteed local rigidity constraints. Radiat Oncol 2016; 11:122. [PMID: 27647456 PMCID: PMC5029058 DOI: 10.1186/s13014-016-0697-4] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2016] [Accepted: 09/09/2016] [Indexed: 11/29/2022] Open
Abstract
Background Deformable image registration (DIR) is a key component in many radiotherapy applications. However, often resulting deformations are not satisfying, since varying deformation properties of different anatomical regions are not considered. To improve the plausibility of DIR in adaptive radiotherapy in the male pelvic area, this work integrates a local rigidity deformation model into a DIR algorithm. Methods A DIR framework is extended by constraints, enforcing locally rigid deformation behavior for arbitrary delineated structures. The approach restricts those structures to rigid deformations, while surrounding tissue is still allowed to deform elastically. The algorithm is tested on ten CT/CBCT male pelvis datasets with active rigidity constraints on bones and prostate and compared to the Varian SmartAdapt deformable registration (VSA) on delineations of bladder, prostate and bones. Results The approach with no rigid structures (REG0) obtains an average dice similarity coefficient (DSC) of 0.87 ± 0.06 and a Hausdorff-Distance (HD) of 8.74 ± 5.95 mm. The new approach with rigid bones (REG1) yields a DSC of 0.87 ± 0.07, HD 8.91 ± 5.89 mm. Rigid deformation of bones and prostate (REG2) obtains 0.87 ± 0.06, HD 8.73 ± 6.01 mm, while VSA yields a DSC of 0.86 ± 0.07, HD 10.22 ± 6.62 mm. No deformation grid foldings are observed for REG0 and REG1 in 7 of 10 cases; for REG2 in 8 of 10 cases, with no grid foldings in prostate, an average of 0.08 % in bladder (REG2: no foldings) and 0.01 % inside the body contour. VSA exhibits grid foldings in each case, with an average percentage of 1.81 % for prostate, 1.74 % for bladder and 0.12 % for the body contour. While REG1 and REG2 keep bones rigid, elastic bone deformations are observed with REG0 and VSA. An average runtime of 26.2 s was achieved with REG1; 31.1 s with REG2, compared to 10.5 s with REG0 and 10.7 s with VMS. Conclusions With accuracy in the range of VSA, the new approach with constraints delivers physically more plausible deformations in the pelvic area with guaranteed rigidity of arbitrary structures. Although the algorithm uses an advanced deformation model, clinically feasible runtimes are achieved. Electronic supplementary material The online version of this article (doi:10.1186/s13014-016-0697-4) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Lars König
- Fraunhofer MEVIS, Maria-Goeppert-Str. 3, Lübeck, 23562, Germany.
| | | | - Nils Papenberg
- Fraunhofer MEVIS, Maria-Goeppert-Str. 3, Lübeck, 23562, Germany
| | - Benjamin Haas
- Varian Medical Systems, Imaging Laboratory GmbH, Täfernstr. 7, Baden, 5405, Switzerland
| |
Collapse
|
14
|
Eccles CL, Tse RV, Hawkins MA, Lee MT, Moseley DJ, Dawson LA. Intravenous contrast-enhanced cone beam computed tomography (IVCBCT) of intrahepatic tumors and vessels. Adv Radiat Oncol 2016; 1:43-50. [PMID: 28740872 PMCID: PMC5506729 DOI: 10.1016/j.adro.2016.01.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2015] [Revised: 01/11/2016] [Accepted: 01/19/2016] [Indexed: 12/03/2022] Open
Abstract
Purpose Liver tumors are challenging to visualize on cone beam computed tomography (CBCT) without intravenous (IV) contrast. Image guidance for liver cancer stereotactic body ablative radiation therapy (SABR) could be improved with the direct visualization of hepatic tumors and vasculature. This study investigated the feasibility of the use of IV contrast-enhanced CBCT (IV-CBCT) as a means to improve liver target visualization. Methods and Materials Patients on a liver SABR protocol underwent IV-CBCT before 1 or more treatment fractions in addition to a noncontrast CBCT. Image acquisition was initiated 0 to 30 seconds following injection and acquired over 60 to 120 seconds. “Stop and go” exhale breath-hold CBCT scans were used whenever feasible. Changes in mean CT number in regions of interest within visible vasculature, tumor, and adjacent liver were quantified between CBCT and IV-CBCT. Results Twelve pairs of contrast and noncontrast CBCTs were obtained in 7 patients. Intravenous-CBCT improved hepatic tumor visibility in breath-hold scans only for 3 patients (2 metastases, 1 hepatocellular carcinoma). Visible tumors ranged in volume from 124 to 564 mL. Small tumors in free-breathing patients did not show enhancement on IVCBT. Conclusions Intravenous-CBCT may enhance the visibility of hepatic vessels and tumor in CBCT scans obtained during breath hold. Optimization of IV contrast timing and reduction of artifacts to improve tumor visualization warrant further investigation.
Collapse
Affiliation(s)
- Cynthia L Eccles
- Radiation Medicine Program, Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Canada.,C.L.E. and M.A.H. are currently at the CRUK/MRC Oxford Institute for Radiation Oncology, University of Oxford, Oxford, United Kingdom
| | - Regina V Tse
- Radiation Medicine Program, Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Canada.,R.V.T. is currently at the Department of Radiation Oncology, Chris O'Brien Lifehouse, Sydney, New South Wales, Australia
| | - Maria A Hawkins
- Radiation Medicine Program, Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Canada.,C.L.E. and M.A.H. are currently at the CRUK/MRC Oxford Institute for Radiation Oncology, University of Oxford, Oxford, United Kingdom
| | - Mark T Lee
- Radiation Medicine Program, Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Canada.,M.T.L. is currently at Cancer Therapy Centre, Liverpool Hospital, University of New South Wales, Australia
| | - Douglas J Moseley
- Radiation Medicine Program, Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Canada
| | - Laura A Dawson
- Radiation Medicine Program, Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Canada
| |
Collapse
|
15
|
Swaminath A, Knox JJ, Brierley JD, Dinniwell R, Wong R, Kassam Z, Kim J, Coolens C, Brock KK, Dawson LA. Changes in Liver Volume Observed Following Sorafenib and Liver Radiation Therapy. Int J Radiat Oncol Biol Phys 2015; 94:729-37. [PMID: 26972645 DOI: 10.1016/j.ijrobp.2015.12.015] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2015] [Revised: 11/03/2015] [Accepted: 12/02/2015] [Indexed: 12/25/2022]
Abstract
PURPOSE The purpose of this study was to quantify unexpected liver volume reductions in patients treated with sorafenib prior to and during liver radiation therapy (RT). METHODS AND MATERIALS Fifteen patients were treated in a phase 1 study of sorafenib for 1 week, followed by concurrent sorafenib-RT (in 6 fractions). Patients had either focal cancer (treated with stereotactic body RT [SBRT]) or diffuse disease (treated with whole-liver RT). Liver volumes were contoured and recorded at planning (day 0) from the exhale CT. After 1 week of sorafenib (day 8), RT image guidance at each fraction was performed using cone beam CT (CBCT). Planning liver contours were propagated and modified on the reconstructed exhale CBCT. This was repeated in 12 patients treated with SBRT alone without sorafenib. Three subsequent patients (2 sorafenib-RT and 1 non-sorafenib) were also assessed with multiphasic helical breath-hold CTs. RESULTS Liver volume reductions on CBCT were observed in the 15 sorafenib-RT patients (median decrease of 68 cc, P=.02) between day 0 and 8; greater in the focal (P=.025) versus diffuse (P=.52) cancer stratum. Seven patients (47%) had reductions larger than the 95% intraobserver contouring error. Liver reductions were also observed from multiphasic CTs in the 2 additional sorafenib-RT patients between days 0 and 8 (decreases of 232.5 cc and 331.7 cc, respectively) and not in the non-sorafenib patient (increase of 92 cc). There were no significant changes in liver volume between planning and first RT in 12 patients with focal cancer treated with SBRT alone (median increase, 4.8 cc, P=.86). CONCLUSIONS Liver volume reductions were observed after 7 days of sorafenib, prior to RT, most marked in patients with focal liver tumors, suggesting an effect of sorafenib on normal liver. Careful assessment of potential liver volume changes immediately prior to SBRT may be necessary in patients in sorafenib or other targeted therapies.
Collapse
Affiliation(s)
- Anand Swaminath
- Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Canada
| | - Jennifer J Knox
- Department of Medical Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Canada
| | - James D Brierley
- Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Canada
| | - Rob Dinniwell
- Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Canada
| | - Rebecca Wong
- Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Canada
| | - Zahra Kassam
- Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Canada
| | - John Kim
- Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Canada
| | - Catherine Coolens
- Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Canada
| | - Kristy K Brock
- Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Canada
| | - Laura A Dawson
- Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Canada.
| |
Collapse
|
16
|
An assessment of interfractional bladder, rectum and vagina motion in postoperative cervical cancer based on daily cone-beam computed tomography. Mol Clin Oncol 2015; 4:271-277. [PMID: 26893874 DOI: 10.3892/mco.2015.704] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2014] [Accepted: 09/08/2015] [Indexed: 02/05/2023] Open
Abstract
Interfractional variations of the bladder, rectum and vagina may affect the accuracy of postoperative intensity-modulated radiotherapy in patients with cervical cancer. This study aimed to assess the interfractional variations with daily kV cone-beam computed tomography (CBCT). All the patients were instructed to control the filling status of the bladder and rectum. CBCT images were obtained daily after set-up and the bladder, rectum and vagina were contoured on each CBCT scan. All the contours were transferred to the planning CT following image fusion. Interfractional variations in pelvic organs were assessed with CBCT based on two reference lines, which were identified as A (the midsaggital line across the superior border of pubic symphysis) and B (a parallel line 1.5 cm above line A). The mean volume (range) of the bladder and rectum was 156.5 (1.7-626.5) and 48.2 (11.3-139.7) ml, respectively. The uniform planning target volume (PTV) margin of 10 mm failed to encompass the vagina in 17.3 and 18.1% of the fractions on lines A and B, respectively. The motion of the vagina (standard deviation) was 0.3 (0.3) and 0.1 (0.5) cm on lines A and B, respectively. The anteroposterior dimension and position of the vagina were significantly affected by the filling status of the bladder (P<0.05), but not by that of the rectum. Although instructions were given, the interfractional variations of the vagina and other pelvic organs were significant, which may exceed the uniform PTV margin; therefore, more effective methods to decrease these variations should be investigated.
Collapse
|
17
|
Lipiodol versus diaphragm in 4D-CBCT-guided stereotactic radiotherapy of hepatocellular carcinomas. Strahlenther Onkol 2015; 192:92-101. [PMID: 26636141 DOI: 10.1007/s00066-015-0929-9] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2015] [Accepted: 11/20/2015] [Indexed: 12/25/2022]
Abstract
PURPOSE The purpose of this work was to investigate the potential of lipiodol as a direct tumor surrogate alternative to the diaphragm surrogate on four-dimensional cone-beam computed tomography (4D-CBCT) image guidance for stereotactic radiotherapy of hepatocellular carcinomas. METHODS A total of 29 hepatocellular carcinomas (HCC) patients treated by stereotactic radiotherapy following transarterial chemoembolization (TACE) with homogeneous or partial defective lipiodol retention were included. In all, 4-7 pretreatment 4D-CBCT scans were selected for each patient. For each scan, either lipiodol or the diaphragm was used for 4D registration. Resulting lipiodol/diaphragm motion ranges and position errors relative to the reconstructed midventilation images were analyzed to obtain the motion variations, and group mean (ΔM), systematic (Σ), and random (σ) errors of the treatment setup. RESULTS Of the lipiodolized tumors, 55 % qualified for direct localization on the 4D-CBCT. Significant correlations of lipiodol and diaphragm positions were found in the left-right (LR), craniocaudal (CC), and anteroposterior (AP) directions. ΔM and σ obtained with lipiodol and diaphragm were similar, agreed to within 0.5 mm in the LR and AP, and 0.3 mm in the CC directions, and Σ differed by 1.4 (LR), 1.1 (CC), and 0.6 (AP) mm. Variations of diaphragm motion range > 5 mm were not observed with lipiodol and in one patient with diaphragm. The margin required for the tumor prediction error using the diaphragm surrogate was 6.7 (LR), 11.7 (CC), and 4.1 (AP) mm. CONCLUSION Image-guidance combining lipiodol with 4D-CBCT enabled accurate localization of HCC and thus margin reduction. A major limitation was the degraded lipiodol contrast on 4D-CBCT.
Collapse
|
18
|
Ahmad S, Khan MF. Topology preserving non-rigid image registration using time-varying elasticity model for MRI brain volumes. Comput Biol Med 2015; 67:21-8. [PMID: 26492319 DOI: 10.1016/j.compbiomed.2015.09.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Accepted: 09/29/2015] [Indexed: 10/22/2022]
Abstract
In this paper, we present a new non-rigid image registration method that imposes a topology preservation constraint on the deformation. We propose to incorporate the time varying elasticity model into the deformable image matching procedure and constrain the Jacobian determinant of the transformation over the entire image domain. The motion of elastic bodies is governed by a hyperbolic partial differential equation, generally termed as elastodynamics wave equation, which we propose to use as a deformation model. We carried out clinical image registration experiments on 3D magnetic resonance brain scans from IBSR database. The results of the proposed registration approach in terms of Kappa index and relative overlap computed over the subcortical structures were compared against the existing topology preserving non-rigid image registration methods and non topology preserving variant of our proposed registration scheme. The Jacobian determinant maps obtained with our proposed registration method were qualitatively and quantitatively analyzed. The results demonstrated that the proposed scheme provides good registration accuracy with smooth transformations, thereby guaranteeing the preservation of topology.
Collapse
Affiliation(s)
- Sahar Ahmad
- National University of Sciences and Technology (NUST), Military College of Signals, Islamabad, Pakistan.
| | - Muhammad Faisal Khan
- National University of Sciences and Technology (NUST), Military College of Signals, Islamabad, Pakistan.
| |
Collapse
|
19
|
Swaminath A, Massey C, Brierley JD, Dinniwell R, Wong R, Kim JJ, Velec M, Brock KK, Dawson LA. Accumulated Delivered Dose Response of Stereotactic Body Radiation Therapy for Liver Metastases. Int J Radiat Oncol Biol Phys 2015; 93:639-48. [PMID: 26461006 DOI: 10.1016/j.ijrobp.2015.07.2273] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2015] [Revised: 07/07/2015] [Accepted: 07/20/2015] [Indexed: 11/29/2022]
Affiliation(s)
- Anand Swaminath
- Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario, Canada
| | - Christine Massey
- Department of Medical Biostatistics, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario, Canada
| | - James D Brierley
- Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario, Canada
| | - Rob Dinniwell
- Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario, Canada
| | - Rebecca Wong
- Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario, Canada
| | - John J Kim
- Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario, Canada
| | - Michael Velec
- Department of Radiation Therapy, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario, Canada
| | - Kristy K Brock
- Department of Medical Biostatistics, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario, Canada
| | - Laura A Dawson
- Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario, Canada.
| |
Collapse
|
20
|
Eng T, Ha CS. Image-guided radiation therapy in lymphoma management. Radiat Oncol J 2015; 33:161-71. [PMID: 26484299 PMCID: PMC4607569 DOI: 10.3857/roj.2015.33.3.161] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2015] [Revised: 09/14/2015] [Accepted: 09/16/2015] [Indexed: 12/17/2022] Open
Abstract
Image-guided radiation therapy (IGRT) is a process of incorporating imaging techniques such as computed tomography (CT), magnetic resonance imaging (MRI), Positron emission tomography (PET), and ultrasound (US) during radiation therapy (RT) to improve treatment accuracy. It allows real-time or near real-time visualization of anatomical information to ensure that the target is in its position as planned. In addition, changes in tumor volume and location due to organ motion during treatment can be also compensated. IGRT has been gaining popularity and acceptance rapidly in RT over the past 10 years, and many published data have been reported on prostate, bladder, head and neck, and gastrointestinal cancers. However, the role of IGRT in lymphoma management is not well defined as there are only very limited published data currently available. The scope of this paper is to review the current use of IGRT in the management of lymphoma. The technical and clinical aspects of IGRT, lymphoma imaging studies, the current role of IGRT in lymphoma management and future directions will be discussed.
Collapse
Affiliation(s)
- Tony Eng
- Department of Radiation Oncology, University of Texas Health Science Center at San Antonio, TX, USA
| | - Chul S. Ha
- Department of Radiation Oncology, University of Texas Health Science Center at San Antonio, TX, USA
| |
Collapse
|
21
|
Brouwer CL, Kierkels RGJ, van 't Veld AA, Sijtsema NM, Meertens H. The effects of computed tomography image characteristics and knot spacing on the spatial accuracy of B-spline deformable image registration in the head and neck geometry. Radiat Oncol 2014; 9:169. [PMID: 25074293 PMCID: PMC4128373 DOI: 10.1186/1748-717x-9-169] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2013] [Accepted: 07/18/2014] [Indexed: 11/10/2022] Open
Abstract
OBJECTIVES To explore the effects of computed tomography (CT) image characteristics and B-spline knot spacing (BKS) on the spatial accuracy of a B-spline deformable image registration (DIR) in the head-and-neck geometry. METHODS The effect of image feature content, image contrast, noise, and BKS on the spatial accuracy of a B-spline DIR was studied. Phantom images were created with varying feature content and varying contrast-to-noise ratio (CNR), and deformed using a known smooth B-spline deformation. Subsequently, the deformed images were repeatedly registered with the original images using different BKSs. The quality of the DIR was expressed as the mean residual displacement (MRD) between the known imposed deformation and the result of the B-spline DIR.Finally, for three patients, head-and-neck planning CT scans were deformed with a realistic deformation field derived from a rescan CT of the same patient, resulting in a simulated deformed image and an a-priori known deformation field. Hence, a B-spline DIR was performed between the simulated image and the planning CT at different BKSs. Similar to the phantom cases, the DIR accuracy was evaluated by means of MRD. RESULTS In total, 162 phantom registrations were performed with varying CNR and BKSs. MRD-values < 1.0 mm were observed with a BKS between 10-20 mm for image contrast ≥ ± 250 HU and noise < ± 200 HU. Decreasing the image feature content resulted in increased MRD-values at all BKSs. Using BKS = 15 mm for the three clinical cases resulted in an average MRD < 1.0 mm. CONCLUSIONS For synthetically generated phantoms and three real CT cases the highest DIR accuracy was obtained for a BKS between 10-20 mm. The accuracy decreased with decreasing image feature content, decreasing image contrast, and higher noise levels. Our results indicate that DIR accuracy in clinical CT images (typical noise levels < ± 100 HU) will not be effected by the amount of image noise.
Collapse
Affiliation(s)
- Charlotte L Brouwer
- University of Groningen, University Medical Center Groningen, Department of Radiation Oncology, Groningen, the Netherlands.
| | | | | | | | | |
Collapse
|
22
|
Reaungamornrat S, Liu WP, Wang AS, Otake Y, Nithiananthan S, Uneri A, Schafer S, Tryggestad E, Richmon J, Sorger JM, Siewerdsen JH, Taylor RH. Deformable image registration for cone-beam CT guided transoral robotic base-of-tongue surgery. Phys Med Biol 2013; 58:4951-79. [PMID: 23807549 PMCID: PMC3990286 DOI: 10.1088/0031-9155/58/14/4951] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Transoral robotic surgery (TORS) offers a minimally invasive approach to resection of base-of-tongue tumors. However, precise localization of the surgical target and adjacent critical structures can be challenged by the highly deformed intraoperative setup. We propose a deformable registration method using intraoperative cone-beam computed tomography (CBCT) to accurately align preoperative CT or MR images with the intraoperative scene. The registration method combines a Gaussian mixture (GM) model followed by a variation of the Demons algorithm. First, following segmentation of the volume of interest (i.e. volume of the tongue extending to the hyoid), a GM model is applied to surface point clouds for rigid initialization (GM rigid) followed by nonrigid deformation (GM nonrigid). Second, the registration is refined using the Demons algorithm applied to distance map transforms of the (GM-registered) preoperative image and intraoperative CBCT. Performance was evaluated in repeat cadaver studies (25 image pairs) in terms of target registration error (TRE), entropy correlation coefficient (ECC) and normalized pointwise mutual information (NPMI). Retraction of the tongue in the TORS operative setup induced gross deformation >30 mm. The mean TRE following the GM rigid, GM nonrigid and Demons steps was 4.6, 2.1 and 1.7 mm, respectively. The respective ECC was 0.57, 0.70 and 0.73, and NPMI was 0.46, 0.57 and 0.60. Registration accuracy was best across the superior aspect of the tongue and in proximity to the hyoid (by virtue of GM registration of surface points on these structures). The Demons step refined registration primarily in deeper portions of the tongue further from the surface and hyoid bone. Since the method does not use image intensities directly, it is suitable to multi-modality registration of preoperative CT or MR with intraoperative CBCT. Extending the 3D image registration to the fusion of image and planning data in stereo-endoscopic video is anticipated to support safer, high-precision base-of-tongue robotic surgery.
Collapse
Affiliation(s)
- S Reaungamornrat
- Department of Computer Science, Johns Hopkins University, Baltimore, MD 21218, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Ung NM, Wee L, Hackett SL, Jones A, Lim TS, Harper CS. Comparison of low-dose, half-rotation, cone-beam CT with electronic portal imaging device for registration of fiducial markers during prostate radiotherapy. J Appl Clin Med Phys 2013; 14:4249. [PMID: 23835391 PMCID: PMC5714542 DOI: 10.1120/jacmp.v14i4.4249] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2012] [Revised: 03/07/2013] [Accepted: 02/26/2013] [Indexed: 11/23/2022] Open
Abstract
This study evaluated the agreement of fiducial marker localization between two modalities — an electronic portal imaging device (EPID) and cone‐beam computed tomography (CBCT) — using a low‐dose, half‐rotation scanning protocol. Twenty‐five prostate cancer patients with implanted fiducial markers were enrolled. Before each daily treatment, EPID and half‐rotation CBCT images were acquired. Translational shifts were computed for each modality and two marker‐matching algorithms, seed‐chamfer and grey‐value, were performed for each set of CBCT images. The localization offsets, and systematic and random errors from both modalities were computed. Localization performances for both modalities were compared using Bland‐Altman limits of agreement (LoA) analysis, Deming regression analysis, and Cohen's kappa inter‐rater analysis. The differences in the systematic and random errors between the modalities were within 0.2 mm in all directions. The LoA analysis revealed a 95% agreement limit of the modalities of 2 to 3.5 mm in any given translational direction. Deming regression analysis demonstrated that constant biases existed in the shifts computed by the modalities in the superior–inferior (SI) direction, but no significant proportional biases were identified in any direction. Cohen's kappa analysis showed good agreement between the modalities in prescribing translational corrections of the couch at 3 and 5 mm action levels. Images obtained from EPID and half‐rotation CBCT showed acceptable agreement for registration of fiducial markers. The seed‐chamfer algorithm for tracking of fiducial markers in CBCT datasets yielded better agreement than the grey‐value matching algorithm with EPID‐based registration. PACS numbers: 87.55.km, 87.55.Qr
Collapse
Affiliation(s)
- Ngie Min Ung
- School of Physics, The University of Western Australia, Western Australia, Australia.
| | | | | | | | | | | |
Collapse
|
24
|
Robertson S, Weiss E, Hugo GD. Deformable mesh registration for the validation of automatic target localization algorithms. Med Phys 2013; 40:071721. [PMID: 23822425 DOI: 10.1118/1.4811105] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To evaluate deformable mesh registration (DMR) as a tool for validating automatic target registration algorithms used during image-guided radiation therapy. METHODS DMR was implemented in a hierarchical model, with rigid, affine, and B-spline transforms optimized in succession to register a pair of surface meshes. The gross tumor volumes (primary tumor and involved lymph nodes) were contoured by a physician on weekly CT scans in a cohort of lung cancer patients and converted to surface meshes. The meshes from weekly CT images were registered to the mesh from the planning CT, and the resulting registered meshes were compared with the delineated surfaces. Known deformations were also applied to the meshes, followed by mesh registration to recover the known deformation. Mesh registration accuracy was assessed at the mesh surface by computing the symmetric surface distance (SSD) between vertices of each registered mesh pair. Mesh registration quality in regions within 5 mm of the mesh surface was evaluated with respect to a high quality deformable image registration. RESULTS For 18 patients presenting with a total of 19 primary lung tumors and 24 lymph node targets, the SSD averaged 1.3 ± 0.5 and 0.8 ± 0.2 mm, respectively. Vertex registration errors (VRE) relative to the applied known deformation were 0.8 ± 0.7 and 0.2 ± 0.3 mm for the primary tumor and lymph nodes, respectively. Inside the mesh surface, corresponding average VRE ranged from 0.6 to 0.9 and 0.2 to 0.9 mm, respectively. Outside the mesh surface, average VRE ranged from 0.7 to 1.8 and 0.2 to 1.4 mm. The magnitude of errors generally increased with increasing distance away from the mesh. CONCLUSIONS Provided that delineated surfaces are available, deformable mesh registration is an accurate and reliable method for obtaining a reference registration to validate automatic target registration algorithms for image-guided radiation therapy, specifically in regions on or near the target surfaces.
Collapse
Affiliation(s)
- Scott Robertson
- Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298, USA
| | | | | |
Collapse
|
25
|
Najmaei N, Mostafavi K, Shahbazi S, Azizian M. Image-guided techniques in renal and hepatic interventions. Int J Med Robot 2012; 9:379-95. [DOI: 10.1002/rcs.1443] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/30/2012] [Indexed: 12/24/2022]
Affiliation(s)
- Nima Najmaei
- Canadian Surgical Technologies and Advanced Robotics (CSTAR); London Health Science Center; London ON Canada
- Department of Electrical and Computer Engineering; University of Western Ontario; London ON Canada
| | - Kamal Mostafavi
- Department of Mechanical Engineering; University of Western Ontario; London ON Canada
| | - Sahar Shahbazi
- Department of Electrical and Computer Engineering; University of Western Ontario; London ON Canada
| | - Mahdi Azizian
- Sheikh Zayed Institute for Pediatric Surgical Innovation; Children's National Medical Center; Washington DC USA
| |
Collapse
|
26
|
Niu CJ, Foltz WD, Velec M, Moseley JL, Al-Mayah A, Brock KK. A novel technique to enable experimental validation of deformable dose accumulation. Med Phys 2012; 39:765-76. [PMID: 22320786 DOI: 10.1118/1.3676185] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To propose a novel technique to experimentally validate deformable dose algorithms by measuring 3D dose distributions under the condition of deformation using deformable gel dosimeters produced by a novel gel fabrication method. METHOD Five gel dosimeters, two rigid control gels and three deformable gels, were manufactured and treated with the same conformal plan that prescribed 400 cGy to the isocenter. The control gels were treated statically; the deformable gels were treated while being compressed by an actuation device to simulate breathing motion (amplitude of compression = 1, 1.5, and 2 cm, respectively; frequency = 16 rpm). Comparison between the dose measured by the control gels and the corresponding static dose distribution calculated in the treatment planning system (TPS) has determined the intrinsic dose measurement uncertainty of the gel dosimeters. Doses accumulated using MORFEUS, a biomechanical model-based deformable registration and dose accumulation algorithm, were compared with the doses measured by the deformable gel dosimeters to verify the accuracy of MORFEUS using dose differences at each voxel as well as the gamma index test. Flexible plastic wraps were used to contain and protect the deformable gels from oxygen infiltration, which inhibits the gels' dose sensitizing ability. Since the wraps were imperfect oxygen barrier, dose comparison between MORFEUS and the deformable gels was performed only in the central region with a received dose of 200 cGy or above to exclude the peripheral region where oxygen penetration had likely affected dose measurements. RESULTS Dose measured with the control gels showed that the intrinsic dose measurement uncertainty of the gel dosimeters was 11.8 cGy or 4.7% compared to the TPS. The absolute mean voxel-by-voxel dose difference between the accumulated dose and the dose measured with the deformable gels was 4.7 cGy (SD = 36.0 cGy) or 1.5% (SD = 13.4%) for the three deformable gels. The absolute mean vector distance between the 250, 300, 350, and 400 cGy isodose surfaces on the accumulated and measured distributions was 1.2 mm (SD < 1.5 mm). The gamma index test that used the dose measurement precision of the control gels as the dose difference criterion and 2 mm as the distance criterion was performed, and the average pass rate of the accumulated dose distributions for all three deformable gels was 92.7%. When the distance criterion was relaxed to 3 mm, the average pass rate increased to 96.9%. CONCLUSION This study has proposed a novel technique to manufacture deformable volumetric gel dosimeters. By comparing the doses accumulated in MORFEUS and the doses measured with the dosimeters under the condition of deformation, the study has also demonstrated the potential of using deformable gel dosimetry to experimentally validate algorithms that include deformations into dose computation. Since dose less than 200 cGy was not evaluated in this study, future investigations will focus more on low dose regions by either using bigger gel dosimeters or prescribing a lower dose to provide a more complete experimental validation of MORFEUS across a wider dose range.
Collapse
Affiliation(s)
- Carolyn J Niu
- Princess Margaret Hospital, University Health Network, Toronto, Ontario, Canada
| | | | | | | | | | | |
Collapse
|
27
|
Robertson SP, Weiss E, Hugo GD. Localization accuracy from automatic and semi-automatic rigid registration of locally-advanced lung cancer targets during image-guided radiation therapy. Med Phys 2012; 39:330-41. [PMID: 22225303 DOI: 10.1118/1.3671929] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
PURPOSE To evaluate localization accuracy resulting from rigid registration of locally-advanced lung cancer targets using fully automatic and semi-automatic protocols for image-guided radiation therapy. METHODS Seventeen lung cancer patients, fourteen also presenting with involved lymph nodes, received computed tomography (CT) scans once per week throughout treatment under active breathing control. A physician contoured both lung and lymph node targets for all weekly scans. Various automatic and semi-automatic rigid registration techniques were then performed for both individual and simultaneous alignments of the primary gross tumor volume (GTV(P)) and involved lymph nodes (GTV(LN)) to simulate the localization process in image-guided radiation therapy. Techniques included "standard" (direct registration of weekly images to a planning CT), "seeded" (manual prealignment of targets to guide standard registration), "transitive-based" (alignment of pretreatment and planning CTs through one or more intermediate images), and "rereferenced" (designation of a new reference image for registration). Localization error (LE) was assessed as the residual centroid and border distances between targets from planning and weekly CTs after registration. RESULTS Initial bony alignment resulted in centroid LE of 7.3 ± 5.4 mm and 5.4 ± 3.4 mm for the GTV(P) and GTV(LN), respectively. Compared to bony alignment, transitive-based and seeded registrations significantly reduced GTV(P) centroid LE to 4.7 ± 3.7 mm (p = 0.011) and 4.3 ± 2.5 mm (p < 1 × 10(-3)), respectively, but the smallest GTV(P) LE of 2.4 ± 2.1 mm was provided by rereferenced registration (p < 1 × 10(-6)). Standard registration significantly reduced GTV(LN) centroid LE to 3.2 ± 2.5 mm (p < 1 × 10(-3)) compared to bony alignment, with little additional gain offered by the other registration techniques. For simultaneous target alignment, centroid LE as low as 3.9 ± 2.7 mm and 3.8 ± 2.3 mm were achieved for the GTV(P) and GTV(LN), respectively, using rereferenced registration. CONCLUSIONS Target shape, volume, and configuration changes during radiation therapy limited the accuracy of standard rigid registration for image-guided localization in locally-advanced lung cancer. Significant error reductions were possible using other rigid registration techniques, with LE approaching the lower limit imposed by interfraction target variability throughout treatment.
Collapse
Affiliation(s)
- Scott P Robertson
- Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298, USA
| | | | | |
Collapse
|
28
|
Accumulated dose in liver stereotactic body radiotherapy: positioning, breathing, and deformation effects. Int J Radiat Oncol Biol Phys 2011; 83:1132-40. [PMID: 22208969 DOI: 10.1016/j.ijrobp.2011.09.045] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2011] [Revised: 09/13/2011] [Accepted: 09/22/2011] [Indexed: 11/24/2022]
Abstract
PURPOSE To investigate the accumulated dose deviations to tumors and normal tissues in liver stereotactic body radiotherapy (SBRT) and investigate their geometric causes. METHODS AND MATERIALS Thirty previously treated liver cancer patients were retrospectively evaluated. Stereotactic body radiotherapy was planned on the static exhale CT for 27-60 Gy in 6 fractions, and patients were treated in free-breathing with daily cone-beam CT guidance. Biomechanical model-based deformable image registration accumulated dose over both the planning four-dimensional (4D) CT (predicted breathing dose) and also over each fraction's respiratory-correlated cone-beam CT (accumulated treatment dose). The contribution of different geometric errors to changes between the accumulated and predicted breathing dose were quantified. RESULTS Twenty-one patients (70%) had accumulated dose deviations relative to the planned static prescription dose >5%, ranging from -15% to 5% in tumors and -42% to 8% in normal tissues. Sixteen patients (53%) still had deviations relative to the 4D CT-predicted dose, which were similar in magnitude. Thirty-two tissues in these 16 patients had deviations >5% relative to the 4D CT-predicted dose, and residual setup errors (n = 17) were most often the largest cause of the deviations, followed by deformations (n = 8) and breathing variations (n = 7). CONCLUSION The majority of patients had accumulated dose deviations >5% relative to the static plan. Significant deviations relative to the predicted breathing dose still occurred in more than half the patients, commonly owing to residual setup errors. Accumulated SBRT dose may be warranted to pursue further dose escalation, adaptive SBRT, and aid in correlation with clinical outcomes.
Collapse
|
29
|
Impact of residual and intrafractional errors on strategy of correction for image-guided accelerated partial breast irradiation. Radiat Oncol 2010; 5:96. [PMID: 20977723 PMCID: PMC2987941 DOI: 10.1186/1748-717x-5-96] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2010] [Accepted: 10/26/2010] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND The cone beam CT (CBCT) guided radiation can reduce the systematic and random setup errors as compared to the skin-mark setup. However, the residual and intrafractional (RAIF) errors are still unknown. The purpose of this paper is to investigate the magnitude of RAIF errors and correction action levels needed in cone beam computed tomography (CBCT) guided accelerated partial breast irradiation (APBI). METHODS Ten patients were enrolled in the prospective study of CBCT guided APBI. The postoperative tumor bed was irradiated with 38.5 Gy in 10 fractions over 5 days. Two cone-beam CT data sets were obtained with one before and one after the treatment delivery. The CBCT images were registered online to the planning CT images using the automatic algorithm followed by a fine manual adjustment. An action level of 3 mm, meaning that corrections were performed for translations exceeding 3 mm, was implemented in clinical treatments. Based on the acquired data, different correction action levels were simulated, and random RAIF errors, systematic RAIF errors and related margins before and after the treatments were determined for varying correction action levels. RESULTS A total of 75 pairs of CBCT data sets were analyzed. The systematic and random setup errors based on skin-mark setup prior to treatment delivery were 2.1 mm and 1.8 mm in the lateral (LR), 3.1 mm and 2.3 mm in the superior-inferior (SI), and 2.3 mm and 2.0 mm in the anterior-posterior (AP) directions. With the 3 mm correction action level, the systematic and random RAIF errors were 2.5 mm and 2.3 mm in the LR direction, 2.3 mm and 2.3 mm in the SI direction, and 2.3 mm and 2.2 mm in the AP direction after treatments delivery. Accordingly, the margins for correction action levels of 3 mm, 4 mm, 5 mm, 6 mm and no correction were 7.9 mm, 8.0 mm, 8.0 mm, 7.9 mm and 8.0 mm in the LR direction; 6.4 mm, 7.1 mm, 7.9 mm, 9.2 mm and 10.5 mm in the SI direction; 7.6 mm, 7.9 mm, 9.4 mm, 10.1 mm and 12.7 mm in the AP direction, respectively. CONCLUSIONS Residual and intrafractional errors can significantly affect the accuracy of image-guided APBI with nonplanar 3DCRT techniques. If a 10-mm CTV-PTV margin is applied, a correction action level of 5 mm or less is necessary so as to maintain the RAIF errors within 10 mm for more than 95% of fractions. Pre-treatment CBCT guidance is not a guarantee for safe delivery of the treatment despite its known benefits of reducing the initial setup errors. A patient position verification and correction during the treatment may be a method for the safe delivery.
Collapse
|
30
|
Interfraction liver shape variability and impact on GTV position during liver stereotactic radiotherapy using abdominal compression. Int J Radiat Oncol Biol Phys 2010; 80:938-46. [PMID: 20947263 DOI: 10.1016/j.ijrobp.2010.08.003] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2009] [Revised: 07/18/2010] [Accepted: 08/03/2010] [Indexed: 02/01/2023]
Abstract
PURPOSE For patients receiving liver stereotactic body radiotherapy (SBRT), abdominal compression can reduce organ motion, and daily image guidance can reduce setup error. The reproducibility of liver shape under compression may impact treatment delivery accuracy. The purpose of this study was to measure the interfractional variability in liver shape under compression, after best-fit rigid liver-to-liver registration from kilovoltage (kV) cone beam computed tomography (CBCT) scans to planning computed tomography (CT) scans and its impact on gross tumor volume (GTV) position. METHODS AND MATERIALS Evaluable patients were treated in a Research Ethics Board-approved SBRT six-fraction study with abdominal compression. Kilovoltage CBCT scans were acquired before treatment and reconstructed as respiratory sorted CBCT scans offline. Manual rigid liver-to-liver registrations were performed from exhale-phase CBCT scans to exhale planning CT scans. Each CBCT liver was contoured, exported, and compared with the planning CT scan for spatial differences, by use of in house-developed finite-element model-based deformable registration (MORFEUS). RESULTS We evaluated 83 CBCT scans from 16 patients with 30 GTVs. The mean volume of liver that deformed by greater than 3 mm was 21.7%. Excluding 1 outlier, the maximum volume that deformed by greater than 3 mm was 36.3% in a single patient. Over all patients, the absolute maximum deformations in the left-right (LR), anterior-posterior (AP), and superior-inferior directions were 10.5 mm (SD, 2.2), 12.9 mm (SD, 3.6), and 5.6 mm (SD, 2.7), respectively. The absolute mean predicted impact of liver volume displacements on GTV by use of center of mass displacements was 0.09 mm (SD, 0.13), 0.13 mm (SD, 0.18), and 0.08 mm (SD, 0.07) in the left-right, anterior-posterior, and superior-inferior directions, respectively. CONCLUSIONS Interfraction liver deformations in patients undergoing SBRT under abdominal compression after rigid liver-to-liver registrations on respiratory sorted CBCT scans were small in most patients (<5 mm).
Collapse
|
31
|
Grau C, Olsen DR, Overgaard J, Høyer M, Lindegaard JC, Muren LP. Biology-guided adaptive radiation therapy - presence or future? Acta Oncol 2010; 49:884-7. [PMID: 20831476 DOI: 10.3109/0284186x.2010.516010] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
MESH Headings
- Adaptation, Biological/physiology
- Adaptation, Biological/radiation effects
- Biology/methods
- Biology/trends
- Dose Fractionation, Radiation
- Fluorodeoxyglucose F18
- Humans
- Radiation Oncology/methods
- Radiation Oncology/trends
- Radiosurgery/methods
- Radiosurgery/trends
- Radiotherapy Dosage
- Radiotherapy, Computer-Assisted/methods
- Radiotherapy, Computer-Assisted/trends
- Radiotherapy, Conformal/adverse effects
- Radiotherapy, Conformal/methods
- Radiotherapy, Conformal/trends
- Surgery, Computer-Assisted/methods
- Surgery, Computer-Assisted/trends
Collapse
|
32
|
Abstract
Adaptive radiation therapy for liver cancer has the potential to reduce normal tissue complications and enable dose escalation, allowing the potential for tumor control in this challenging site. Using adaptive techniques to tailor treatment margins to reflect patient-specific breathing motions and image-guidance techniques can reduce the high dose delivered to surrounding normal tissues while ensuring that the prescription dose is delivered to the tumor. Several treatment planning and delivery techniques have been developed for use in the liver, including a margin to encompass the full breathing motion, mean position techniques, which evaluate the probability of tumor location during breathing, breath hold, gating, and tracking. Patient selection, clinical workflow, and quality assurance must be considered and developed before integrating these techniques into clinical practice.
Collapse
Affiliation(s)
- Kristy K Brock
- Department of Radiation Oncology, Princess Margaret Hospital, University Health Network, University of Toronto, Toronto, ON, Canada.
| | | |
Collapse
|
33
|
Weiss E, Wu J, Sleeman W, Bryant J, Mitra P, Myers M, Ivanova T, Mukhopadhyay N, Ramakrishnan V, Murphy M, Williamson J. Clinical evaluation of soft tissue organ boundary visualization on cone-beam computed tomographic imaging. Int J Radiat Oncol Biol Phys 2010; 78:929-36. [PMID: 20542644 DOI: 10.1016/j.ijrobp.2010.02.007] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2009] [Revised: 02/06/2010] [Accepted: 02/10/2010] [Indexed: 11/17/2022]
Abstract
PURPOSE Cone-beam computed tomographic images (CBCTs) are increasingly used for setup correction, soft tissue targeting, and image-guided adaptive radiotherapy. However, CBCT image quality is limited by low contrast and imaging artifacts. This analysis investigates the detectability of soft tissue boundaries in CBCT by performing a multiple-observer segmentation study. METHODS AND MATERIALS In four prostate cancer patients prostate, bladder and rectum were repeatedly delineated by five observers on CBCTs and fan-beam CTs (FBCTs). A volumetric analysis of contouring variations was performed by calculating coefficients of variation (COV: standard deviation/average volume). The topographical distribution of contouring variations was analyzed using an average surface mesh-based method. RESULTS Observer- and patient-averaged COVs for FBCT/CBCT were 0.09/0.19 for prostate, 0.05/0.08 for bladder, and 0.09/0.08 for rectum. Contouring variations on FBCT were significantly smaller than on CBCT for prostate (p < 0.03) and bladder (p < 0.04), but not for rectum (p < 0.37; intermodality differences). Intraobserver variations from repeated contouring of the same image set were not significant for either FBCT or CBCT (p < 0.05). Average standard deviations of individual observers' contour differences from average surface meshes on FBCT vs. CBCT were 1.5 vs. 2.1 mm for prostate, 0.7 vs. 1.4 mm for bladder, and 1.3 vs. 1.5 mm for rectum. The topographical distribution of contouring variations was similar for FBCT and CBCT. CONCLUSION Contouring variations were larger on CBCT than FBCT, except for rectum. Given the well-documented uncertainty in soft tissue contouring in the pelvis, improvement of CBCT image quality and establishment of well-defined soft tissue identification rules are desirable for image-guided radiotherapy.
Collapse
Affiliation(s)
- Elisabeth Weiss
- Department of Radiation Oncology, Virginia Commonwealth University, Richmond, VA 23298, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
34
|
Ng A, Nguyen TN, Moseley JL, Hodgson DC, Sharpe MB, Brock KK. Reconstruction of 3D lung models from 2D planning data sets for Hodgkin's lymphoma patients using combined deformable image registration and navigator channels. Med Phys 2010; 37:1017-28. [PMID: 20384237 DOI: 10.1118/1.3284368] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Late complications (cardiac toxicities, secondary lung, and breast cancer) remain a significant concern in the radiation treatment of Hodgkin's lymphoma (HL). To address this issue, predictive dose-risk models could potentially be used to estimate radiotherapy-related late toxicities. This study investigates the use of deformable image registration (DIR) and navigator channels (NCs) to reconstruct 3D lung models from 2D radiographic planning images, in order to retrospectively calculate the treatment dose exposure to HL patients treated with 2D planning, which are now experiencing late effects. METHODS Three-dimensional planning CT images of 52 current HL patients were acquired. 12 image sets were used to construct a male and a female population lung model. 23 "Reference" images were used to generate lung deformation adaptation templates, constructed by deforming the population model into each patient-specific lung geometry using a biomechanical-based DIR algorithm, MORFEUS. 17 "Test" patients were used to test the accuracy of the reconstruction technique by adapting existing templates using 2D digitally reconstructed radiographs. The adaptation process included three steps. First, a Reference patient was matched to a Test patient by thorax measurements. Second, four NCs (small regions of interest) were placed on the lung boundary to calculate 1D differences in lung edges. Third, the Reference lung model was adapted to the Test patient's lung using the 1D edge differences. The Reference-adapted Test model was then compared to the 3D lung contours of the actual Test patient by computing their percentage volume overlap (POL) and Dice coefficient. RESULTS The average percentage overlapping volumes and Dice coefficient expressed as a percentage between the adapted and actual Test models were found to be 89.2 +/- 3.9% (Right lung = 88.8%; Left lung = 89.6%) and 89.3 +/- 2.7% (Right = 88.5%; Left = 90.2%), respectively. Paired T-tests demonstrated that the volumetric reconstruction method made a statistically significant improvement to the population lung model shape (p < 0.05). The error in the results were also comparable to the volume overlap difference observed between inhale and exhale lung volumes during free-breathing respiratory motion (POL: p = 0.43; Dice: p = 0.20), which implies that the accuracies of the reconstruction method are within breathing constraints and would not be the confining factor in estimating normal tissue dose exposure. CONCLUSIONS The result findings show that the DIR-NC technique can achieve a high degree of reconstruction accuracy, and could be useful in approximating 3D dosimetric representations of historical 2D treatment. In turn, this could provide a better understanding of the biophysical relationship between dose-volume exposure and late term radiotherapy effects.
Collapse
Affiliation(s)
- Angela Ng
- Radiation Medicine Program, Princess Margaret Hospital, University Health Network, Toronto, Ontario M5G 2M9, Canada
| | | | | | | | | | | |
Collapse
|
35
|
Case RB, Moseley DJ, Sonke JJ, Eccles CL, Dinniwell RE, Kim J, Bezjak A, Milosevic M, Brock KK, Dawson LA. Interfraction and intrafraction changes in amplitude of breathing motion in stereotactic liver radiotherapy. Int J Radiat Oncol Biol Phys 2010; 77:918-25. [PMID: 20207501 DOI: 10.1016/j.ijrobp.2009.09.008] [Citation(s) in RCA: 79] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2008] [Revised: 08/12/2009] [Accepted: 09/14/2009] [Indexed: 11/29/2022]
Abstract
PURPOSE Interfraction and intrafraction changes in amplitude of liver motion were assessed in patients with liver cancer treated with kV cone beam computed tomography (CBCT)-guided stereotactic body radiation therapy (SBRT). METHODS AND MATERIALS A total of 314 CBCTs obtained with the patient in the treatment position immediately before and after each fraction, and 29 planning 4DCTs were evaluated in 29 patients undergoing six-fraction SBRT for unresectable liver cancer, with (n = 15) and without (n = 14) abdominal compression. Offline, the CBCTs were sorted into 10 bins, based on phase of respiration. Liver motion amplitude was measured using liver-to-liver alignment from the end-exhale and end-inhale CBCT and four-dimensional CT reconstructions. Inter- and intrafraction amplitude changes were measured from the difference between the pre-SBRT CBCTs relative to the planning four-dimensional CT, and from the pre-SBRT and post-SBRT CBCTs, respectively. RESULTS Mean liver motion amplitude for all patients (range) was 1.8 (0.1-7.0), 8.0 (0.1-18.8), and 4.3 (0.1-12.1) mm in the mediolateral (ML), craniocaudal (CC), and anteroposterior (AP) directions, respectively. Mean absolute inter- and intrafraction liver motion amplitude changes were 1.0 (ML), 1.7 (CC), and 1.6 (AP) mm and 1.3 (ML), 1.6 (CC), and 1.9 (AP) mm, respectively. No significant correlations were found between intrafraction amplitude change and intrafraction time (range, 4:56-25:37 min:sec), and between inter- and intrafraction amplitude changes and liver motion amplitude. Intraobserver reproducibility (sigma, n = 29 fractions) was 1.3 (ML), 1.4 (CC), and 1.4 (AP) mm. CONCLUSIONS For the majority of liver SBRT patients, the change in liver motion amplitude was minimal over the treatment course and showed no apparent relationships with the magnitude of liver motion and intrafraction time.
Collapse
Affiliation(s)
- Robert B Case
- Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario, Canada
| | | | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Velec M, Waldron JN, O'Sullivan B, Bayley A, Cummings B, Kim JJ, Ringash J, Breen SL, Lockwood GA, Dawson LA. Cone-Beam CT Assessment of Interfraction and Intrafraction Setup Error of Two Head-and-Neck Cancer Thermoplastic Masks. Int J Radiat Oncol Biol Phys 2010; 76:949-55. [PMID: 20056344 DOI: 10.1016/j.ijrobp.2009.07.004] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2009] [Revised: 07/01/2009] [Accepted: 07/01/2009] [Indexed: 10/20/2022]
|
37
|
Korreman S, Rasch C, McNair H, Verellen D, Oelfke U, Maingon P, Mijnheer B, Khoo V. The European Society of Therapeutic Radiology and Oncology-European Institute of Radiotherapy (ESTRO-EIR) report on 3D CT-based in-room image guidance systems: a practical and technical review and guide. Radiother Oncol 2010; 94:129-44. [PMID: 20153908 DOI: 10.1016/j.radonc.2010.01.004] [Citation(s) in RCA: 132] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2009] [Revised: 01/08/2010] [Accepted: 01/16/2010] [Indexed: 01/03/2023]
Abstract
The past decade has provided many technological advances in radiotherapy. The European Institute of Radiotherapy (EIR) was established by the European Society of Therapeutic Radiology and Oncology (ESTRO) to provide current consensus statement with evidence-based and pragmatic guidelines on topics of practical relevance for radiation oncology. This report focuses primarily on 3D CT-based in-room image guidance (3DCT-IGRT) systems. It will provide an overview and current standing of 3DCT-IGRT systems addressing the rationale, objectives, principles, applications, and process pathways, both clinical and technical for treatment delivery and quality assurance. These are reviewed for four categories of solutions; kV CT and kV CBCT (cone-beam CT) as well as MV CT and MV CBCT. It will also provide a framework and checklist to consider the capability and functionality of these systems as well as the resources needed for implementation. Two different but typical clinical cases (tonsillar and prostate cancer) using 3DCT-IGRT are illustrated with workflow processes via feedback questionnaires from several large clinical centres currently utilizing these systems. The feedback from these clinical centres demonstrates a wide variability based on local practices. This report whilst comprehensive is not exhaustive as this area of development remains a very active field for research and development. However, it should serve as a practical guide and framework for all professional groups within the field, focussed on clinicians, physicists and radiation therapy technologists interested in IGRT.
Collapse
Affiliation(s)
- Stine Korreman
- Department of Radiation Oncology, The Finsen Centre, Rigshospitalet, Copenhagen, Denmark
| | | | | | | | | | | | | | | |
Collapse
|
38
|
A method for patient set-up guidance in radiotherapy using augmented reality. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2009; 32:203-11. [DOI: 10.1007/bf03179240] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
39
|
Case RB, Sonke JJ, Moseley DJ, Kim J, Brock KK, Dawson LA. Inter- and Intrafraction Variability in Liver Position in Non–Breath-Hold Stereotactic Body Radiotherapy. Int J Radiat Oncol Biol Phys 2009; 75:302-8. [DOI: 10.1016/j.ijrobp.2009.03.058] [Citation(s) in RCA: 101] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2008] [Revised: 03/25/2009] [Accepted: 03/26/2009] [Indexed: 10/20/2022]
|
40
|
Grau C, Muren LP, Høyer M, Lindegaard J, Overgaard J. Image-guided adaptive radiotherapy - integration of biology and technology to improve clinical outcome. Acta Oncol 2009; 47:1182-5. [PMID: 18654901 DOI: 10.1080/02841860802282802] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
41
|
|