1
|
Zhao LL, Lu XZ, Tang GD, Zhang XY, Li RK, Xu J, Feng JJ, Xu Z, Song JK, Bi HS. Anterior chamber and angle characteristics in Chinese children (6-11 years old) with different refractive status using swept-source optical coherence tomography. BMC Ophthalmol 2024; 24:259. [PMID: 38880899 PMCID: PMC11181599 DOI: 10.1186/s12886-024-03520-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Accepted: 06/07/2024] [Indexed: 06/18/2024] Open
Abstract
BACKGROUND The anatomic structure of the anterior chamber (AC) helps to explain differences in refractive status in school-aged children and is closely associated with primary angle closure (PAC). The aim of this study was to quantify and analyze the anterior chamber and angle (ACA) characteristics in Chinese children with different refractive status by swept-source optical coherence tomography (SS-OCT). METHODS In a cross-sectional observational study, 383 children from two primary schools in Shandong Province, China, underwent a complete ophthalmic examination. First, the anterior chamber depth (ACD), anterior chamber width (ACW), angle-opening distance (AOD), and trabecular-iris space area (TISA) were evaluated automatically using a CASIA2 imaging device. AOD and TISA were measured at 500, 750 μm nasal (N1 and N2, respectively), and temporal (T1 and T2, respectively) to the scleral spur (SS). Cycloplegic refraction and axial length (AL) were then measured. According to spherical equivalent refraction (SER), the children were assigned to hyperopic (SER > 0.50D), emmetropic (-0.50D < SER ≤ 0.50D), and myopic groups (SER ≤ -0.50D). RESULTS Out of the 383 children, 349 healthy children (160 girls) with a mean age of 8.23 ± 1.06 years (range: 6-11 years) were included. The mean SER and AL were - 0.10 ± 1.57D and 23.44 ± 0.95 mm, respectively. The mean ACD and ACW were 3.17 ± 0.24 mm and 11.69 ± 0.43 mm. The mean AOD were 0.72 ± 0.25, 0.63 ± 0.22 mm at N1, T1, and 0.98 ± 0.30, 0.84 ± 0.27 mm at N2, T2. The mean TISA were 0.24 ± 0.09, 0.22 ± 0.09mm2 at N1, T1, and 0.46 ± 0.16, 0.40 ± 0.14mm2 at N2, T2. The myopic group had the deepest AC and the widest angle. Compared with boys, girls had shorter AL, shallower ACD, narrower ACW, and ACA (all p < 0.05). By Pearson's correlation analysis, SER was negatively associated with ACD, AOD, and TISA. AL was positively associated with ACD, ACW, AOD, and TISA. In the multiple regression analysis, AOD and TISA were associated with deeper ACD, narrower ACW, and longer AL. CONCLUSION In primary school students, the myopic eyes have deeper AC and wider angle. ACD, ACW, AOD, and TISA all increase with axial elongation. ACA is highly correlated with deeper ACD.
Collapse
Affiliation(s)
- Li Li Zhao
- Shandong University of Traditional Chinese Medicine, Jinan, 250014, PR China
| | - Xiu Zhen Lu
- Affiliated Eye Hospital of Shandong University of Traditional Chinese Medicine, Jinan, 250000, PR China
- Shandong Provincial Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Therapy of Ocular Diseases, Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Therapy of Ocular Diseases in Universities of Shandong, Eye Institute of Shandong University of Traditional Chinese Medicine, Jinan, 250000, PR China
| | - Guo Dong Tang
- Affiliated Eye Hospital of Shandong University of Traditional Chinese Medicine, Jinan, 250000, PR China
- Shandong Provincial Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Therapy of Ocular Diseases, Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Therapy of Ocular Diseases in Universities of Shandong, Eye Institute of Shandong University of Traditional Chinese Medicine, Jinan, 250000, PR China
| | - Xiu Yan Zhang
- Affiliated Eye Hospital of Shandong University of Traditional Chinese Medicine, Jinan, 250000, PR China
- Shandong Provincial Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Therapy of Ocular Diseases, Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Therapy of Ocular Diseases in Universities of Shandong, Eye Institute of Shandong University of Traditional Chinese Medicine, Jinan, 250000, PR China
| | - Run Kuan Li
- Shandong University of Traditional Chinese Medicine, Jinan, 250014, PR China
| | - Jing Xu
- Shandong University of Traditional Chinese Medicine, Jinan, 250014, PR China
| | - Jiao Jiao Feng
- Shandong University of Traditional Chinese Medicine, Jinan, 250014, PR China
| | - Zhe Xu
- Shandong University of Traditional Chinese Medicine, Jinan, 250014, PR China
| | - Ji Ke Song
- Shandong University of Traditional Chinese Medicine, Jinan, 250014, PR China.
- Shandong Provincial Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Therapy of Ocular Diseases, Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Therapy of Ocular Diseases in Universities of Shandong, Eye Institute of Shandong University of Traditional Chinese Medicine, Jinan, 250000, PR China.
| | - Hong Sheng Bi
- Affiliated Eye Hospital of Shandong University of Traditional Chinese Medicine, Jinan, 250000, PR China.
- Shandong Provincial Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Therapy of Ocular Diseases, Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Therapy of Ocular Diseases in Universities of Shandong, Eye Institute of Shandong University of Traditional Chinese Medicine, Jinan, 250000, PR China.
| |
Collapse
|
2
|
Trout RM, Viehland C, Li JD, Raynor W, Dhalla AH, Vajzovic L, Kuo AN, Toth CA, Izatt JA. Methods for real-time feature-guided image fusion of intrasurgical volumetric optical coherence tomography with digital microscopy. BIOMEDICAL OPTICS EXPRESS 2023; 14:3308-3326. [PMID: 37497493 PMCID: PMC10368056 DOI: 10.1364/boe.488975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 06/01/2023] [Accepted: 06/01/2023] [Indexed: 07/28/2023]
Abstract
4D-microscope-integrated optical coherence tomography (4D-MIOCT) is an emergent multimodal imaging technology in which live volumetric OCT (4D-OCT) is implemented in tandem with standard stereo color microscopy. 4D-OCT provides ophthalmic surgeons with many useful visual cues not available in standard microscopy; however it is challenging for the surgeon to effectively integrate cues from simultaneous-but-separate imaging in real-time. In this work, we demonstrate progress towards solving this challenge via the fusion of data from each modality guided by segmented 3D features. In this way, a more readily interpretable visualization that combines and registers important cues from both modalities is presented to the surgeon.
Collapse
Affiliation(s)
- Robert M. Trout
- Department of Biomedical Engineering, Duke University, 101 Science Drive, Durham, NC 27708, USA
| | - Christian Viehland
- Department of Biomedical Engineering, Duke University, 101 Science Drive, Durham, NC 27708, USA
| | - Jianwei D. Li
- Department of Biomedical Engineering, Duke University, 101 Science Drive, Durham, NC 27708, USA
| | - William Raynor
- Department of Ophthalmology, Duker University Medical Center, 2351 Erwin Road, Durham, NC 27705, USA
| | - Al-Hafeez Dhalla
- Department of Biomedical Engineering, Duke University, 101 Science Drive, Durham, NC 27708, USA
| | - Lejla Vajzovic
- Department of Ophthalmology, Duker University Medical Center, 2351 Erwin Road, Durham, NC 27705, USA
| | - Anthony N. Kuo
- Department of Biomedical Engineering, Duke University, 101 Science Drive, Durham, NC 27708, USA
- Department of Ophthalmology, Duker University Medical Center, 2351 Erwin Road, Durham, NC 27705, USA
| | - Cynthia A. Toth
- Department of Biomedical Engineering, Duke University, 101 Science Drive, Durham, NC 27708, USA
- Department of Ophthalmology, Duker University Medical Center, 2351 Erwin Road, Durham, NC 27705, USA
| | - Joseph A. Izatt
- Department of Biomedical Engineering, Duke University, 101 Science Drive, Durham, NC 27708, USA
| |
Collapse
|
3
|
Mirzayev I, Gündüz AK, Aydın Ellialtıoğlu P, Gündüz ÖÖ. Clinical applications of anterior segment swept-source optical coherence tomography: A systematic review. Photodiagnosis Photodyn Ther 2023; 42:103334. [PMID: 36764640 DOI: 10.1016/j.pdpdt.2023.103334] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Revised: 01/25/2023] [Accepted: 02/07/2023] [Indexed: 02/11/2023]
Abstract
Optical coherence tomography (OCT) is a non-invasive method that provides the opportunity to examine tissues by taking cross-sectional images. OCT is increasingly being used to evaluate anterior segment (AS) pathologies. Swept-source (SS) OCT allows greater penetration and achieves better visualization of the internal configuration of AS tissues due to the longer wavelength employed and high scan speeds. We reviewed the utilization of AS SS-OCT in various conditions including glaucoma, ocular surface pathologies, iris tumors, refractive surgery, cataract surgery, and scleral diseases. A systematic literature search was carried out on PubMed, Scopus, and Web of Science databases between January 1, 2008, and September 1, 2022 using the following keywords: AS SS-OCT; dry eye and SS-OCT; ocular surface and SS-OCT; cornea and SS-OCT; dystrophy and SS-OCT; glaucoma and SS-OCT; ocular surface tumors and SS-OCT; conjunctival tumors and SS-OCT; refractive surgery and SS-OCT; cataract and SS-OCT; biometry and SS-OCT; sclera and SS-OCT; iris and SS-OCT; ciliary body and SS-OCT; artificial intelligence and SS-OCT. A total of 221 studies were included in this review. Review of the existing literature shows that SS-OCT offers several advantages in the diagnosis of AS diseases. Exclusive features of SS-OCT including rapid scanning, deeper tissue penetration, and better image quality help improve our understanding of various AS pathologies.
Collapse
Affiliation(s)
- Ibadulla Mirzayev
- Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey; Halil Şıvgın Çubuk State Hospital, Ophthalmology Clinic, Ankara, Turkey
| | - Ahmet Kaan Gündüz
- Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey; Private Eye Clinic, Ankara, Turkey.
| | | | - Ömür Özlenen Gündüz
- Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey
| |
Collapse
|
4
|
Incidence and Risk Factors for Berger's Space Development after Uneventful Cataract Surgery: Evidence from Swept-Source Optical Coherence Tomography. J Clin Med 2022; 11:jcm11133580. [PMID: 35806863 PMCID: PMC9267354 DOI: 10.3390/jcm11133580] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 06/07/2022] [Accepted: 06/15/2022] [Indexed: 02/04/2023] Open
Abstract
Background: This study investigates the incidence and risk factors for the development of Berger’s space (BS) after uneventful phacoemulsification based on swept-source optical coherence tomography (SS-OCT). Methods: Cataractous eyes captured using qualified SS-OCT images before and after uneventful phacoemulsification cataract surgery were included. Six high-resolution cross-sectional anterior segment SS-OCT images at 30° intervals were used for BS data measurements. BS width was measured at three points on each scanned meridian line: the central point line aligned with the cornea vertex and two point lines at the pupil’s margins. Results: A total of 223 eyes that underwent uneventful cataract surgery were evaluated. Preoperatively, only two eyes (2/223, 0.9%) were observed to have consistent BS in all six scanning directions. BS was observed postoperatively in 44 eyes (44/223, 19.7%). A total of 13 eyes (13/223, 5.8%) with insufficient image quality, pupil dilation, or lack of preoperative image data were excluded from the study. A total of 31 postoperative eyes with BS and 31 matched eyes without BS were included in the final data analysis. The smallest postoperative BS width was in the upper quadrant of the vertical meridian line (90°), with a mean value of 280 μm. The largest BS width was observed in the opposite area of the main clear corneal incision, with a mean value >500 μm. Conclusions: Uneven-width BS is observable after uneventful phacoemulsification. Locations with a much wider BS (indirect manifestation of Wieger zonular detachment) are predominantly located in the opposite direction to the main corneal incisions.
Collapse
|
5
|
Pujari A, Modaboyina S, Das D, Mahajan A, Thangavel R, Phuljhele S, Saxena R, Sharma N, Sharma P. Clinical Role of Swept Source Anterior Segment Optical Coherence Tomography in Strabismus Re-Operation with Lost Surgical Details. Clin Ophthalmol 2021; 15:3581-3591. [PMID: 34471343 PMCID: PMC8403674 DOI: 10.2147/opth.s328215] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Accepted: 07/27/2021] [Indexed: 12/04/2022] Open
Abstract
Background To characterize the diagnostic role of swept source anterior segment optical coherence tomography (SS-ASOCT) in strabismus re-operations with lost surgical details. Methods Patients presenting to our outpatient services for strabismus care from February 2020 to March 15th 2021 were systematically evaluated. Those willing to undergo re-operation were included in the study. A total of 30 patients were identified and out of this a total of 10 eyes of 10 patients with lost surgical details were finally included in the study. Demographic details, preoperative deviation, ocular findings, orthoptic measurements, detailed SS-ASOCT findings, intraoperative measurements, and post-operative outcomes were recorded. Results The mean age of 10 patients was 23.7±5.75 years. Seven were male and three were female. The mean pre-operative SS-ASOCT measured distance from angle to insertion was 8.90±1.85 mm and the mean intraoperative distance was 9.12±2.14 mm. A mean difference of 0.21±1.31 mm was noted, and this difference was statistically insignificant (paired t test, p = 0.57). In addition, SS-ASOCT unraveled novel signs to differentiate operated eyes from the un-operated eyes, and recessed muscle from the resected muscle. Conclusion In strabismus re-operation with lost surgical details, the pre-operative SS-ASOCT can provide reliable muscle details with respect to its type of surgery and amount surgery.
Collapse
Affiliation(s)
- Amar Pujari
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Sujeeth Modaboyina
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Deepsekhar Das
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Asmita Mahajan
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Rajeswari Thangavel
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Swati Phuljhele
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Rohit Saxena
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Namrata Sharma
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Pradeep Sharma
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| |
Collapse
|