1
|
Loureiro J, Bogatu L, Schmitt L, Henriques J, Carvalho P, Noordergraaf GJ, Paulussen I, Muehlsteff J. Towards continuous non-invasive blood pressure measurements-interpretation of the vasculature response to cuff inflation. Front Physiol 2023; 14:1172688. [PMID: 37334047 PMCID: PMC10272798 DOI: 10.3389/fphys.2023.1172688] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 05/19/2023] [Indexed: 06/20/2023] Open
Abstract
Blood pressure (BP) surrogates, such as pulse transit time (PTT) or pulse arrival time (PAT), have been intensively explored with the goal of achieving cuffless, continuous, and accurate BP inference. In order to estimate BP, a one-point calibration strategy between PAT and BP is typically used. Recent research focuses on advanced calibration procedures exploiting the cuff inflation process to improve calibration robustness by active and controlled modulation of peripheral PAT, as measured via plethysmograph (PPG) and electrocardiogram (ECG) combination. Such methods require a detailed understanding of the mechanisms behind the vasculature's response to cuff inflation; for this, a model has recently been developed to infer the PAT-BP calibration from measured cuff-induced vasculature changes. The model, while promising, is still preliminary and only partially validated; in-depth analysis and further developments are still needed. Therefore, this work aims to improve our understanding of the cuff-vasculature interaction in this model; we seek to define potential opportunities and to highlight which aspects may require further study. We compare model behaviors with clinical data samples based on a set of observable characteristics relevant for BP inference and calibration. It is found that the observed behaviors are qualitatively well represented with the current simulation model and complexity, with limitations regarding the prediction of the onset of the distal arm dynamics and behavior changes at high cuff pressures. Additionally, a sensitivity analysis of the model's parameter space is conducted to show the factors that influence the characteristics of its observable outputs. It was revealed that easily controllable experimental variables, such as lateral cuff length and inflation rate, have a significant impact on cuff-induced vasculature changes. An interesting dependency between systemic BP and cuff-induced distal PTT change is also found, revealing opportunities for improved methods for BP surrogate calibration. However, validation via patient data shows that this relation does not hold for all patients, indicating required model improvements to be validated in follow up studies. These results provide promising directions to improve the calibration process featuring cuff inflation towards accurate and robust non-invasive blood pressure estimation.
Collapse
Affiliation(s)
- João Loureiro
- Centre for Informatics and Systems of the University of Coimbra, University of Coimbra, Department of Informatics Engineering, Coimbra, Portugal
| | - Laura Bogatu
- Department of Patient Care and Measurements, Philips Research, Eindhoven, Netherlands
| | - Lars Schmitt
- Department of Patient Care and Measurements, Philips Research, Eindhoven, Netherlands
| | - Jorge Henriques
- Centre for Informatics and Systems of the University of Coimbra, University of Coimbra, Department of Informatics Engineering, Coimbra, Portugal
| | - Paulo Carvalho
- Centre for Informatics and Systems of the University of Coimbra, University of Coimbra, Department of Informatics Engineering, Coimbra, Portugal
| | - Gerrit J. Noordergraaf
- Department of Anesthesiology and Pain Management, Elisabeth-Tweesteden Hospital, Tilburg, Netherlands
| | - Igor Paulussen
- Department of Patient Care and Measurements, Philips Research, Eindhoven, Netherlands
- Department of Anesthesiology and Pain Management, Elisabeth-Tweesteden Hospital, Tilburg, Netherlands
| | - Jens Muehlsteff
- Department of Patient Care and Measurements, Philips Research, Eindhoven, Netherlands
| |
Collapse
|
2
|
Man PK, Cheung KL, Sangsiri N, Shek WJ, Wong KL, Chin JW, Chan TT, So RHY. Blood Pressure Measurement: From Cuff-Based to Contactless Monitoring. Healthcare (Basel) 2022; 10:healthcare10102113. [PMID: 36292560 PMCID: PMC9601911 DOI: 10.3390/healthcare10102113] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 09/26/2022] [Accepted: 10/02/2022] [Indexed: 11/04/2022] Open
Abstract
Blood pressure (BP) determines whether a person has hypertension and offers implications as to whether he or she could be affected by cardiovascular disease. Cuff-based sphygmomanometers have traditionally provided both accuracy and reliability, but they require bulky equipment and relevant skills to obtain precise measurements. BP measurement from photoplethysmography (PPG) signals has become a promising alternative for convenient and unobtrusive BP monitoring. Moreover, the recent developments in remote photoplethysmography (rPPG) algorithms have enabled new innovations for contactless BP measurement. This paper illustrates the evolution of BP measurement techniques from the biophysical theory, through the development of contact-based BP measurement from PPG signals, and to the modern innovations of contactless BP measurement from rPPG signals. We consolidate knowledge from a diverse background of academic research to highlight the importance of multi-feature analysis for improving measurement accuracy. We conclude with the ongoing challenges, opportunities, and possible future directions in this emerging field of research.
Collapse
Affiliation(s)
- Ping-Kwan Man
- PanopticAI, Hong Kong Science and Technology Parks, New Territories, Hong Kong, China
- Correspondence:
| | - Kit-Leong Cheung
- PanopticAI, Hong Kong Science and Technology Parks, New Territories, Hong Kong, China
- Department of Computer Science and Engineering, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong, China
| | - Nawapon Sangsiri
- PanopticAI, Hong Kong Science and Technology Parks, New Territories, Hong Kong, China
- Department of Computer Science and Engineering, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong, China
| | - Wilfred Jin Shek
- PanopticAI, Hong Kong Science and Technology Parks, New Territories, Hong Kong, China
- Department of Biomedical Sciences, King’s College London, London WC2R 2LS, UK
| | - Kwan-Long Wong
- PanopticAI, Hong Kong Science and Technology Parks, New Territories, Hong Kong, China
- Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China
| | - Jing-Wei Chin
- PanopticAI, Hong Kong Science and Technology Parks, New Territories, Hong Kong, China
- Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China
| | - Tsz-Tai Chan
- PanopticAI, Hong Kong Science and Technology Parks, New Territories, Hong Kong, China
- Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China
| | - Richard Hau-Yue So
- PanopticAI, Hong Kong Science and Technology Parks, New Territories, Hong Kong, China
- Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China
| |
Collapse
|
3
|
Andrew Koman L. Management of upper extremity arterial penetrating vascular trauma. Injury 2021; 52:3573-3579. [PMID: 34756412 DOI: 10.1016/j.injury.2021.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Revised: 09/28/2021] [Accepted: 10/01/2021] [Indexed: 02/02/2023]
Abstract
Penetrating vascular injuries in the upper extremity are relatively uncommon; suboptimal treatment may result in significant morbidity including amputation. Arterial trauma accounted for 68% of amputations (24% in the upper extremity) during World War II. Although surgical techniques including microsurgical principles have matured, results vary secondary to the mechanism of injury, systemic factors, anatomic considerations and physiologic events. This annotated review article is based upon the literature and the author's 42 years of vascular trauma experience including over 1500 revascularizations and replantations. It discusses the complex interplay of associated injuries; the mechanism of injury, the location of the injury; the collateral circulation; the extent of soft tissue damage; the adequacy of debridement; the significance of pre-existing conditions; and magnitude of wound contamination. Based upon this evaluation, a guide to indications for arterial reconstruction is provided and a comprehensive management plan for vascular trauma may be derived.
Collapse
Affiliation(s)
- L Andrew Koman
- Department Orthopaedic Surgery and Rehabilitation, Wake Forest School of Medicine, Atrium Health Wake Forest Baptist, Medical Center Boulevard, Winston-Salem, North Carolina, USA 27157.
| |
Collapse
|
4
|
Bogatu LI, Turco S, Mischi M, Schmitt L, Woerlee P, Bresch E, Noordergraaf GJ, Paulussen I, Bouwman A, Korsten EHHM, Muehlsteff J. Modulation of pulse travel and blood flow during cuff inflation- An experimental case study. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:23-26. [PMID: 34891230 DOI: 10.1109/embc46164.2021.9629718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The blood pressure (BP) cuff can be used to modulate blood flow and propagation of pressure pulse along the artery. In our previous work, we researched methods to adapt cuff modulation techniques for pulse transit time vs. BP calibration and for measurement of other hemodynamic indices of potential interest to critical care, such as arterial compliance. A model characterized the response of the vasculature located directly under the cuff, but assumed that no significant changes occur in the distal vasculature.This study has been tailored to gain insights into the response of distal BP and pulse transit time to cuff inflation. Invasive BP data collected downstream from the cuff demonstrates that highly dynamic processes occur in the distal arm during cuff inflation. Mean arterial pressure increases in the distal artery by up to 20 mmHg, leading to a decrease in pulse transit time of up to 20 ms. Clinical Relevance: Such significant changes need to be taken into account in order to improve non-invasive BP estimations and to enable inference of other hemodynamic parameters from vasculature response to cuff inflation. A simple model is developed in order to reproduce the observed behaviors. The lumped-parameter model demonstrates opportunities for cuff modulation measurements which can reveal information on parameters such as systemic resistance, distal arterial, venous compliances and artery-vein interaction.
Collapse
|
5
|
Bogatu LI, Turco S, Mischi M, Schmitt L, Woerlee P, Bresch E, Noordergraaf GJ, Paulussen I, Bouwman A, Korsten HHM, Muehlsteff J. Modulation of Pulse Propagation and Blood Flow via Cuff Inflation-New Distal Insights. SENSORS 2021; 21:s21165593. [PMID: 34451035 PMCID: PMC8402247 DOI: 10.3390/s21165593] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 07/26/2021] [Accepted: 08/16/2021] [Indexed: 11/30/2022]
Abstract
In standard critical care practice, cuff sphygmomanometry is widely used for intermittent blood pressure (BP) measurements. However, cuff devices offer ample possibility of modulating blood flow and pulse propagation along the artery. We explore underutilized arrangements of sensors involving cuff devices which could be of use in critical care to reveal additional information on compensatory mechanisms. In our previous work, we analyzed the response of the vasculature to occlusion perturbations by means of observations obtained non-invasively. In this study, our aim is to (1) acquire additional insights by means of invasive measurements and (2) based on these insights, further develop cuff-based measurement strategies. Invasive BP experimental data is collected downstream from the cuff in two patients monitored in the OR. It is found that highly dynamic processes occur in the distal arm during cuff inflation. Mean arterial pressure increases in the distal artery by 20 mmHg, leading to a decrease in pulse transit time by 20 ms. Previous characterizations neglected such distal vasculature effects. A model is developed to reproduce the observed behaviors and to provide a possible explanation of the factors that influence the distal arm mechanisms. We apply the new findings to further develop measurement strategies aimed at acquiring information on pulse arrival time vs. BP calibration, artery compliance, peripheral resistance, artery-vein interaction.
Collapse
Affiliation(s)
- Laura I. Bogatu
- Department of Electrical Engineering, Eindhoven University of Technology, 5612AZ Eindhoven, The Netherlands; (S.T.); (M.M.); (P.W.)
- Philips Research, 5656AE Eindhoven, The Netherlands; (L.S.); (E.B.); (I.P.); (J.M.)
- Correspondence:
| | - Simona Turco
- Department of Electrical Engineering, Eindhoven University of Technology, 5612AZ Eindhoven, The Netherlands; (S.T.); (M.M.); (P.W.)
| | - Massimo Mischi
- Department of Electrical Engineering, Eindhoven University of Technology, 5612AZ Eindhoven, The Netherlands; (S.T.); (M.M.); (P.W.)
| | - Lars Schmitt
- Philips Research, 5656AE Eindhoven, The Netherlands; (L.S.); (E.B.); (I.P.); (J.M.)
| | - Pierre Woerlee
- Department of Electrical Engineering, Eindhoven University of Technology, 5612AZ Eindhoven, The Netherlands; (S.T.); (M.M.); (P.W.)
| | - Erik Bresch
- Philips Research, 5656AE Eindhoven, The Netherlands; (L.S.); (E.B.); (I.P.); (J.M.)
| | | | - Igor Paulussen
- Philips Research, 5656AE Eindhoven, The Netherlands; (L.S.); (E.B.); (I.P.); (J.M.)
- Elisabeth-TweeSteden Hospital, 5022GC Tilburg, The Netherlands;
| | - Arthur Bouwman
- Catharina Ziekenhuis, 5623EJ Eindhoven, The Netherlands; (A.B.); (H.H.M.K.)
| | | | - Jens Muehlsteff
- Philips Research, 5656AE Eindhoven, The Netherlands; (L.S.); (E.B.); (I.P.); (J.M.)
| |
Collapse
|
6
|
Charlton PH, Mariscal Harana J, Vennin S, Li Y, Chowienczyk P, Alastruey J. Modeling arterial pulse waves in healthy aging: a database for in silico evaluation of hemodynamics and pulse wave indexes. Am J Physiol Heart Circ Physiol 2019; 317:H1062-H1085. [PMID: 31442381 PMCID: PMC6879924 DOI: 10.1152/ajpheart.00218.2019] [Citation(s) in RCA: 80] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2019] [Revised: 07/09/2019] [Accepted: 07/28/2019] [Indexed: 11/22/2022]
Abstract
The arterial pulse wave (PW) is a rich source of information on cardiovascular (CV) health. It is widely measured by both consumer and clinical devices. However, the physical determinants of the PW are not yet fully understood, and the development of PW analysis algorithms is limited by a lack of PW data sets containing reference CV measurements. Our aim was to create a database of PWs simulated by a computer to span a range of CV conditions, representative of a sample of healthy adults. The typical CV properties of 25-75 yr olds were identified through a literature review. These were used as inputs to a computational model to simulate PWs for subjects of each age decade. Pressure, flow velocity, luminal area, and photoplethysmographic PWs were simulated at common measurement sites, and PW indexes were extracted. The database, containing PWs from 4,374 virtual subjects, was verified by comparing the simulated PWs and derived indexes with corresponding in vivo data. Good agreement was observed, with well-reproduced age-related changes in hemodynamic parameters and PW morphology. The utility of the database was demonstrated through case studies providing novel hemodynamic insights, in silico assessment of PW algorithms, and pilot data to inform the design of clinical PW algorithm assessments. In conclusion, the publicly available PW database is a valuable resource for understanding CV determinants of PWs and for the development and preclinical assessment of PW analysis algorithms. It is particularly useful because the exact CV properties that generated each PW are known.NEW & NOTEWORTHY First, a comprehensive literature review of changes in cardiovascular properties with age was performed. Second, an approach for simulating pulse waves (PWs) at different ages was designed and verified against in vivo data. Third, a PW database was created, and its utility was illustrated through three case studies investigating the determinants of PW indexes. Fourth, the database and tools for creating the database, analyzing PWs, and replicating the case studies are freely available.
Collapse
Affiliation(s)
- Peter H Charlton
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, King's Health Partners, London, United Kingdom
| | - Jorge Mariscal Harana
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, King's Health Partners, London, United Kingdom
| | - Samuel Vennin
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, King's Health Partners, London, United Kingdom
- Department of Clinical Pharmacology, King's College London, King's Health Partners, London, United Kingdom
| | - Ye Li
- Department of Clinical Pharmacology, King's College London, King's Health Partners, London, United Kingdom
| | - Phil Chowienczyk
- Department of Clinical Pharmacology, King's College London, King's Health Partners, London, United Kingdom
| | - Jordi Alastruey
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, King's Health Partners, London, United Kingdom
- Institute of Personalized Medicine, Sechenov University, Moscow, Russia
| |
Collapse
|
7
|
Larson K, Bowman C, Papadimitriou C, Koumoutsakos P, Matzavinos A. Detection of arterial wall abnormalities via Bayesian model selection. ROYAL SOCIETY OPEN SCIENCE 2019; 6:182229. [PMID: 31824680 PMCID: PMC6837237 DOI: 10.1098/rsos.182229] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Accepted: 09/17/2019] [Indexed: 06/10/2023]
Abstract
Patient-specific modelling of haemodynamics in arterial networks has so far relied on parameter estimation for inexpensive or small-scale models. We describe here a Bayesian uncertainty quantification framework which makes two major advances: an efficient parallel implementation, allowing parameter estimation for more complex forward models, and a system for practical model selection, allowing evidence-based comparison between distinct physical models. We demonstrate the proposed methodology by generating simulated noisy flow velocity data from a branching arterial tree model in which a structural defect is introduced at an unknown location; our approach is shown to accurately locate the abnormality and estimate its physical properties even in the presence of significant observational and systemic error. As the method readily admits real data, it shows great potential in patient-specific parameter fitting for haemodynamical flow models.
Collapse
Affiliation(s)
- Karen Larson
- Division of Applied Mathematics, Brown University, Providence, RI 02912, USA
| | - Clark Bowman
- Department of Mathematics and Statistics, Hamilton College, Clinton, NY 13323, USA
| | - Costas Papadimitriou
- Department of Mechanical Engineering, University of Thessaly, 38334 Volos, Greece
| | - Petros Koumoutsakos
- Computational Science and Engineering Laboratory, ETH Zürich CH-8092, Switzerland
| | | |
Collapse
|
8
|
Epstein S, Willemet M, Chowienczyk PJ, Alastruey J. Reducing the number of parameters in 1D arterial blood flow modeling: less is more for patient-specific simulations. Am J Physiol Heart Circ Physiol 2015; 309:H222-34. [PMID: 25888513 PMCID: PMC4491523 DOI: 10.1152/ajpheart.00857.2014] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2014] [Accepted: 04/11/2015] [Indexed: 01/09/2023]
Abstract
Patient-specific one-dimensional (1D) blood flow modeling requires estimating model parameters from available clinical data, ideally acquired noninvasively. The larger the number of arterial segments in a distributed 1D model, the greater the number of input parameters that need to be estimated. We investigated the effect of a reduction in the number of arterial segments in a given distributed 1D model on the shape of the simulated pressure and flow waveforms. This is achieved by systematically lumping peripheral 1D model branches into windkessel models that preserve the net resistance and total compliance of the original model. We applied our methodology to a model of the 55 larger systemic arteries in the human and to an extended 67-artery model that contains the digital arteries that perfuse the fingers. Results show good agreement in the shape of the aortic and digital waveforms between the original 55-artery (67-artery) and reduced 21-artery (37-artery) models. Reducing the number of segments also enables us to investigate the effect of arterial network topology (and hence reflection sites) on the shape of waveforms. Results show that wave reflections in the thoracic aorta and renal arteries play an important role in shaping the aortic pressure and flow waves and in generating the second peak of the digital pressure and flow waves. Our novel methodology is important to simplify the computational domain while maintaining the precision of the numerical predictions and to assess the effect of wave reflections.
Collapse
Affiliation(s)
- Sally Epstein
- Division of Imaging Sciences and Biomedical Engineering, St. Thomas' Hospital, King's College London, London, United Kingdom; and
| | - Marie Willemet
- Division of Imaging Sciences and Biomedical Engineering, St. Thomas' Hospital, King's College London, London, United Kingdom; and
| | - Phil J Chowienczyk
- Department of Clinical Pharmacology, St. Thomas' Hospital, King's College London, London, United Kingdom
| | - Jordi Alastruey
- Division of Imaging Sciences and Biomedical Engineering, St. Thomas' Hospital, King's College London, London, United Kingdom; and
| |
Collapse
|
9
|
Epstein S, Vergnaud AC, Elliott P, Chowienczyk P, Alastruey J. Numerical assessment of the stiffness index. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2014; 2014:1969-1972. [PMID: 25570367 DOI: 10.1109/embc.2014.6943999] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Elevated systemic vascular stiffness is associated with increased risk of cardiovascular disease. It has been suggested that the time difference between the two characteristic peaks of the digital volume pulse (DVP) measured at the finger using photoplethysmography is related to the stiffness of the arterial tree, and inversely proportional to the stiffness index (SI). However, the precise physical meaning of the SI and its relation to aortic pulse wave velocity (aPWV) is yet to be ascertained. In this study we investigated numerically the effect of changes in arterial wall stiffness, peripheral resistances, peripheral compliances or peripheral wave reflections on the SI and aPWV. The SI was calculated from the digital area waveform simulated using a nonlinear one-dimensional model of pulse wave propagation in a 75-artery network, which includes the larger arteries of the hand. Our results show that aPWV is affected by changes in aortic stiffness, but the SI is primarily affected by changes in the stiffness of all conduit vessels. Thus, the SI is not a direct substitute for aPWV. Moreover, our results suggest that peripheral reflections in the upper body delay the time of arrival of the first peak in the DVP. The second peak is predominantly caused by the impedance mismatch within the 75 arterial segments, rather than by peripheral reflections.
Collapse
|
10
|
Alastruey J, Khir AW, Matthys KS, Segers P, Sherwin SJ, Verdonck PR, Parker KH, Peiró J. Pulse wave propagation in a model human arterial network: Assessment of 1-D visco-elastic simulations against in vitro measurements. J Biomech 2011; 44:2250-8. [PMID: 21724188 PMCID: PMC3278302 DOI: 10.1016/j.jbiomech.2011.05.041] [Citation(s) in RCA: 160] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2010] [Revised: 05/27/2011] [Accepted: 05/27/2011] [Indexed: 11/17/2022]
Abstract
The accuracy of the nonlinear one-dimensional (1-D) equations of pressure and flow wave propagation in Voigt-type visco-elastic arteries was tested against measurements in a well-defined experimental 1:1 replica of the 37 largest conduit arteries in the human systemic circulation. The parameters required by the numerical algorithm were directly measured in the in vitro setup and no data fitting was involved. The inclusion of wall visco-elasticity in the numerical model reduced the underdamped high-frequency oscillations obtained using a purely elastic tube law, especially in peripheral vessels, which was previously reported in this paper [Matthys et al., 2007. Pulse wave propagation in a model human arterial network: Assessment of 1-D numerical simulations against in vitro measurements. J. Biomech. 40, 3476–3486]. In comparison to the purely elastic model, visco-elasticity significantly reduced the average relative root-mean-square errors between numerical and experimental waveforms over the 70 locations measured in the in vitro model: from 3.0% to 2.5% (p<0.012) for pressure and from 15.7% to 10.8% (p<0.002) for the flow rate. In the frequency domain, average relative errors between numerical and experimental amplitudes from the 5th to the 20th harmonic decreased from 0.7% to 0.5% (p<0.107) for pressure and from 7.0% to 3.3% (p<10−6) for the flow rate. These results provide additional support for the use of 1-D reduced modelling to accurately simulate clinically relevant problems at a reasonable computational cost.
Collapse
Affiliation(s)
- Jordi Alastruey
- Department of Bioengineering, Imperial College, London SW7 2AZ, UK.
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Willemet M, Lacroix V, Marchandise E. Inlet boundary conditions for blood flow simulations in truncated arterial networks. J Biomech 2011; 44:897-903. [DOI: 10.1016/j.jbiomech.2010.11.036] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2010] [Revised: 10/28/2010] [Accepted: 11/30/2010] [Indexed: 10/18/2022]
|
12
|
Waters SL, Alastruey J, Beard DA, Bovendeerd PHM, Davies PF, Jayaraman G, Jensen OE, Lee J, Parker KH, Popel AS, Secomb TW, Siebes M, Sherwin SJ, Shipley RJ, Smith NP, van de Vosse FN. Theoretical models for coronary vascular biomechanics: progress & challenges. PROGRESS IN BIOPHYSICS AND MOLECULAR BIOLOGY 2011; 104:49-76. [PMID: 21040741 PMCID: PMC3817728 DOI: 10.1016/j.pbiomolbio.2010.10.001] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2009] [Revised: 09/17/2010] [Accepted: 10/06/2010] [Indexed: 01/09/2023]
Abstract
A key aim of the cardiac Physiome Project is to develop theoretical models to simulate the functional behaviour of the heart under physiological and pathophysiological conditions. Heart function is critically dependent on the delivery of an adequate blood supply to the myocardium via the coronary vasculature. Key to this critical function of the coronary vasculature is system dynamics that emerge via the interactions of the numerous constituent components at a range of spatial and temporal scales. Here, we focus on several components for which theoretical approaches can be applied, including vascular structure and mechanics, blood flow and mass transport, flow regulation, angiogenesis and vascular remodelling, and vascular cellular mechanics. For each component, we summarise the current state of the art in model development, and discuss areas requiring further research. We highlight the major challenges associated with integrating the component models to develop a computational tool that can ultimately be used to simulate the responses of the coronary vascular system to changing demands and to diseases and therapies.
Collapse
Affiliation(s)
- Sarah L Waters
- Oxford Centre for Industrial and Applied mathematics, Mathematical Institute, 24-29 St Giles', Oxford, OX1 3LB, UK.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Alastruey J, Sherwin SJ, Parker KH, Rubens DD. Placental transfusion insult in the predisposition for SIDS: a mathematical study. Early Hum Dev 2009; 85:455-9. [PMID: 19446412 DOI: 10.1016/j.earlhumdev.2009.04.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2008] [Revised: 02/17/2009] [Accepted: 04/01/2009] [Indexed: 11/17/2022]
Abstract
A difference has been observed between the newborn hearing screening tests of thirty-one SIDS cases versus control infants that survived the first year of life [Rubens DD, Vohr BV, Tucker R, O'Neil CA, Chung W. Newborn oto-acoustic emission hearing screening tests. Preliminary evidence for a marker of susceptibility to SIDS. Early Hum Dev 2008;84(4);225-9]. This study is motivated by the hypothesis that the predisposition for SIDS may be caused by inner ear and brainstem damage from a high venous pressure insult at birth that disrupts an infant's ability to detect rising CO(2) levels following the first month of life. The injury is not immediately lethal due to the persistence of fetal physiological responses during the early postnatal period [Guntheroth WG. Crib death, the Sudden Infant Death Syndrome. Armonk NY: Futura Publishing Co.; 1995. p. 291]. Elastic vessels are assumed in the umbilical vein and newborn venous circulation at the time of a potential high pressure placental transfusion insult and pulse wave propagation is simulated using the nonlinear one-dimensional equations of blood flow in elastic vessels. Peak pressures in the auricular veins increase with the amplitude and length of the umbilical surge, reaching over 60 mm Hg when two consecutive surges separated by 100 ms, of a peak pressure of 100 mm Hg, and a pulse interval of 200 ms are propagated in a network with low peripheral reflections. Our findings support the proposed mechanism for inner ear damage in SIDS and the potential benefit of a newborn hearing screening test in identifying susceptibility and early preventative measures following birth.
Collapse
|
14
|
Marchandise E, Willemet M, Lacroix V. A numerical hemodynamic tool for predictive vascular surgery. Med Eng Phys 2009; 31:131-44. [DOI: 10.1016/j.medengphy.2008.04.015] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2007] [Revised: 04/14/2008] [Accepted: 04/30/2008] [Indexed: 10/21/2022]
|
15
|
Mynard JP, Nithiarasu P. A 1D arterial blood flow model incorporating ventricular pressure, aortic valve and regional coronary flow using the locally conservative Galerkin (LCG) method. ACTA ACUST UNITED AC 2008. [DOI: 10.1002/cnm.1117] [Citation(s) in RCA: 163] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
16
|
Matthys KS, Alastruey J, Peiró J, Khir AW, Segers P, Verdonck PR, Parker KH, Sherwin SJ. Pulse wave propagation in a model human arterial network: Assessment of 1-D numerical simulations against in vitro measurements. J Biomech 2007; 40:3476-86. [PMID: 17640653 DOI: 10.1016/j.jbiomech.2007.05.027] [Citation(s) in RCA: 135] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2007] [Revised: 05/21/2007] [Accepted: 05/28/2007] [Indexed: 11/17/2022]
Abstract
A numerical model based on the nonlinear, one-dimensional (1-D) equations of pressure and flow wave propagation in conduit arteries is tested against a well-defined experimental 1:1 replica of the human arterial tree. The tree consists of 37 silicone branches representing the largest central systemic arteries in the human, including the aorta, carotid arteries and arteries that perfuse the upper and lower limbs and the main abdominal organs. The set-up is mounted horizontally and connected to a pulsatile pump delivering a periodic output similar to the aortic flow. Terminal branches end in simple resistance models, consisting of stiff capillary tubes leading to an overflow reservoir that reflects a constant venous pressure. The parameters required by the numerical algorithm are directly measured in the in vitro set-up and no data fitting is involved. Comparison of experimental and numerical pressure and flow waveforms shows the ability of the 1-D time-domain formulation to capture the main features of pulse wave propagation measured throughout the system test. As a consequence of the simple resistive boundary conditions used to reduce the uncertainty of the parameters involved in the simulation, the experimental set-up generates waveforms at terminal branches with additional non-physiological oscillations. The frequencies of these oscillations are well captured by the 1-D model, even though amplitudes are overestimated. Adding energy losses in bifurcations and including fluid inertia and compliance to the purely resistive terminal models does not reduce the underdamped effect, suggesting that wall visco-elasticity might play an important role in the experimental results. Nevertheless, average relative root-mean-square errors between simulations and experimental waveforms are smaller than 4% for pressure and 19% for the flow at all 70 locations studied.
Collapse
Affiliation(s)
- Koen S Matthys
- Department of Aeronautics, Imperial College London, London, UK
| | | | | | | | | | | | | | | |
Collapse
|