1
|
Xian RP, Brunet J, Huang Y, Wagner WL, Lee PD, Tafforeau P, Walsh CL. A closer look at high-energy X-ray-induced bubble formation during soft tissue imaging. JOURNAL OF SYNCHROTRON RADIATION 2024; 31:566-577. [PMID: 38682274 DOI: 10.1107/s160057752400290x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Accepted: 04/02/2024] [Indexed: 05/01/2024]
Abstract
Improving the scalability of tissue imaging throughput with bright, coherent X-rays requires identifying and mitigating artifacts resulting from the interactions between X-rays and matter. At synchrotron sources, long-term imaging of soft tissues in solution can result in gas bubble formation or cavitation, which dramatically compromises image quality and integrity of the samples. By combining in-line phase-contrast imaging with gas chromatography in real time, we were able to track the onset and evolution of high-energy X-ray-induced gas bubbles in ethanol-embedded soft tissue samples for tens of minutes (two to three times the typical scan times). We demonstrate quantitatively that vacuum degassing of the sample during preparation can significantly delay bubble formation, offering up to a twofold improvement in dose tolerance, depending on the tissue type. However, once nucleated, bubble growth is faster in degassed than undegassed samples, indicating their distinct metastable states at bubble onset. Gas chromatography analysis shows increased solvent vaporization concurrent with bubble formation, yet the quantities of dissolved gasses remain unchanged. By coupling features extracted from the radiographs with computational analysis of bubble characteristics, we uncover dose-controlled kinetics and nucleation site-specific growth. These hallmark signatures provide quantitative constraints on the driving mechanisms of bubble formation and growth. Overall, the observations highlight bubble formation as a critical yet often overlooked hurdle in upscaling X-ray imaging for biological tissues and soft materials and we offer an empirical foundation for their understanding and imaging protocol optimization. More importantly, our approaches establish a top-down scheme to decipher the complex, multiscale radiation-matter interactions in these applications.
Collapse
Affiliation(s)
- R Patrick Xian
- Department of Mechanical Engineering, University College London, London, United Kingdom
| | - Joseph Brunet
- Department of Mechanical Engineering, University College London, London, United Kingdom
| | - Yuze Huang
- Department of Mechanical Engineering, University College London, London, United Kingdom
| | - Willi L Wagner
- Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Peter D Lee
- Department of Mechanical Engineering, University College London, London, United Kingdom
| | - Paul Tafforeau
- European Synchrotron Radiation Facility, Grenoble, France
| | - Claire L Walsh
- Department of Mechanical Engineering, University College London, London, United Kingdom
| |
Collapse
|
2
|
Rachkidi M, Michel A, Raffin G, Barattin R, Colinet E, Randon J. Characterization of semi-packed columns with different cross section in high-pressure gas chromatography. J Chromatogr A 2024; 1722:464869. [PMID: 38604057 DOI: 10.1016/j.chroma.2024.464869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 04/01/2024] [Accepted: 04/02/2024] [Indexed: 04/13/2024]
Abstract
Hydrodynamics, efficiency, and loading capacity of two semi-packed columns with different cross sections (NANO 315 µm x 18 µm; CAP 1000 µm x 28 µm) and similar pillar diameter and pillar-pillar distance (respectively 5 µm and 2.5 µm) have been compared in high-pressure gas chromatography. A flow prediction tool has been first designed to determine pressure variations and hold-up time across the chromatographic system taking into account the rectangular geometry of the ducts into the semi-packed columns. Intrinsic values of Height Equivalent to Theoretical Plate were determined for NANO and CAP columns using helium as carrier gas and similar values have been obtained (30 µm) for the two columns. Loading capacity of semi-packed columns were determined for decane at 70 °C using helium, and the highest value was obtained from CAP column (larger cross section and stationary phase content). Finally, significant HETP improvement (down to 15 µm) and peak shape were observed when carbon dioxide was used as carrier gas, suggesting mobile phase adsorption on stationary phase in high pressure conditions.
Collapse
Affiliation(s)
- Michel Rachkidi
- APIX Analytics, 38000 Grenoble, France; Universite Claude Bernard Lyon1, ISA, UMR 5280, CNRS, 5 rue de la Doua, 69100 Villeurbanne, France.
| | - Ambroisine Michel
- APIX Analytics, 38000 Grenoble, France; Universite Claude Bernard Lyon1, ISA, UMR 5280, CNRS, 5 rue de la Doua, 69100 Villeurbanne, France
| | - Guy Raffin
- Universite Claude Bernard Lyon1, ISA, UMR 5280, CNRS, 5 rue de la Doua, 69100 Villeurbanne, France
| | | | | | - Jérôme Randon
- Universite Claude Bernard Lyon1, ISA, UMR 5280, CNRS, 5 rue de la Doua, 69100 Villeurbanne, France
| |
Collapse
|
3
|
Chen B, Zhu Y, Ma S, Zhao B, Feng F. A semi-packed gas chromatographic column with staggered elliptic cylindrical post arrays. Analyst 2024; 149:1579-1585. [PMID: 38288594 DOI: 10.1039/d3an02016a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/27/2024]
Abstract
A semi-packed gas chromatographic column has the advantages of high specific surface area and low column pressure. We report that the stagnation regions formed in the adjacent posts along the channel of the semi-packed columns can decrease the area and height of chromatographic peaks, which makes it difficult to detect low-concentration mixed gases. A semi-packed column with staggered elliptic cylindrical post arrays (SC-S) made using a micro-electro-mechanical system technique is presented, and the separation performance of SC-S is compared with that of a semi-packed column with aligned elliptic cylindrical post arrays (SC-A). The simulation results show that the width of stagnation regions in SC-S is 86.89% smaller than that in SC-A. The experimental results indicate that the area and height of chromatographic peaks increased as stagnation regions reduced. In the separation of the alkane mixture from C8 through C10 with 10 ppm concentration, the chromatographic peak of decane was hardly identified in SC-A while the chromatographic peak in SC-S was still clearly visible. The chromatographic peak heights of octane and nonane were increased by 65.06% and 130.00%, respectively, in SC-S. The peak areas of octane and nonane were increased by 120.45% and 168.18%, respectively.
Collapse
Affiliation(s)
- Boxin Chen
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yuchen Zhu
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Shaojie Ma
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Bin Zhao
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Fei Feng
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
4
|
Epping R, Koch M. On-Site Detection of Volatile Organic Compounds (VOCs). Molecules 2023; 28:1598. [PMID: 36838585 PMCID: PMC9966347 DOI: 10.3390/molecules28041598] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 02/03/2023] [Accepted: 02/05/2023] [Indexed: 02/11/2023] Open
Abstract
Volatile organic compounds (VOCs) are of interest in many different fields. Among them are food and fragrance analysis, environmental and atmospheric research, industrial applications, security or medical and life science. In the past, the characterization of these compounds was mostly performed via sample collection and off-site analysis with gas chromatography coupled to mass spectrometry (GC-MS) as the gold standard. While powerful, this method also has several drawbacks such as being slow, expensive, and demanding on the user. For decades, intense research has been dedicated to find methods for fast VOC analysis on-site with time and spatial resolution. We present the working principles of the most important, utilized, and researched technologies for this purpose and highlight important publications from the last five years. In this overview, non-selective gas sensors, electronic noses, spectroscopic methods, miniaturized gas chromatography, ion mobility spectrometry and direct injection mass spectrometry are covered. The advantages and limitations of the different methods are compared. Finally, we give our outlook into the future progression of this field of research.
Collapse
Affiliation(s)
- Ruben Epping
- Division of Organic Trace and Food Analysis, Bundesanstalt für Materialforschung und -Prüfung, 12489 Berlin, Germany
| | - Matthias Koch
- Division of Organic Trace and Food Analysis, Bundesanstalt für Materialforschung und -Prüfung, 12489 Berlin, Germany
| |
Collapse
|
5
|
Crucello J, de Oliveira AM, Sampaio NMFM, Hantao LW. Miniaturized systems for gas chromatography: Developments in sample preparation and instrumentation. J Chromatogr A 2022; 1685:463603. [DOI: 10.1016/j.chroma.2022.463603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 10/07/2022] [Accepted: 10/23/2022] [Indexed: 11/07/2022]
|
6
|
Meziani A, Verloy S, Ferroukhi O, Roca S, Curat A, Tisse S, Peulon-Agasse V, Gardeniers H, Desmet G, Cardinael P. Evaluation of Gas Chromatography Columns with Radially Elongated Pillars as Second-Dimension Columns in Comprehensive Two-Dimensional Gas Chromatography. Anal Chem 2022; 94:14126-14134. [PMID: 36194872 DOI: 10.1021/acs.analchem.2c01264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The present study investigated the use of a dedicated gas chromatography (GC) column (L = 70 cm, 75 μm deep, and 6.195 mm wide) with radially elongated pillars (REPs) as the second column in a comprehensive two-dimensional gas chromatography (GC × μGC) system. Three stationary phases [apolar polydimethylsiloxane (PDMS), medium polar room-temperature ionic liquid (RTIL) based on monocationic phosphonium, and polar polyethylene glycol (PEG-1000)] have been coated using the static method at constant pressure or using an original vacuum pressure program (VPP) from 400 to 4 mbar. The best efficiency reached up to N = 62,000 theoretical plates for a film thickness of 47 nm at 100 °C for an iso-octane peak (k = 0.16) at an optimal flow rate of 4.8 mL/min. The use of the VPP improved the efficiency by approximately 15%. Efficiencies up to 28,000 and 47,000 were obtained for PEG-1000 and RTIL, respectively. A temperature-programmed separation of a mixture of 11 volatile compounds on a PDMS-coated chip was obtained in less than 36 s. The PDMS-, PEG-1000-, and RTIL-coated chips were tested as the second column using a microfluidic reverse fill/flush flow modulator in a GC × μGC system. The REP columns were highly compatible with the operating conditions in terms of flow rate and with more than 30,000 plates for the iso-octane peak. Moreover, a commercial solvent called white spirit containing alkanes and aromatic compounds was injected in three sets of columns in normal and reverse modes, demonstrating the great potential of the chip as a second-dimension separation column.
Collapse
Affiliation(s)
- Amel Meziani
- Univ Rouen Normandie, FR CNRS 3038, SMS, UR3233, Rouen F-76000, France.,Laboratoire de Chromatographie, Faculté de Chimie, USTHB, BP 32 EL-Alia, Alger 16111, Algeria
| | - Sandrien Verloy
- Department of Chemical Engineering CHIS, Vrije Universiteit Brussel, Brussels 1050, Belgium.,Mesoscale Chemical Systems, University of Twente, Enschede 7522, North Brabant, Netherlands
| | - Ouassila Ferroukhi
- Laboratoire de Chromatographie, Faculté de Chimie, USTHB, BP 32 EL-Alia, Alger 16111, Algeria
| | - Sebastien Roca
- Univ Rouen Normandie, FR CNRS 3038, SMS, UR3233, Rouen F-76000, France
| | - Aurelien Curat
- Univ Rouen Normandie, FR CNRS 3038, SMS, UR3233, Rouen F-76000, France
| | - Severine Tisse
- Univ Rouen Normandie, FR CNRS 3038, SMS, UR3233, Rouen F-76000, France
| | | | - Han Gardeniers
- Mesoscale Chemical Systems, University of Twente, Enschede 7522, North Brabant, Netherlands
| | - Gert Desmet
- Department of Chemical Engineering CHIS, Vrije Universiteit Brussel, Brussels 1050, Belgium
| | - Pascal Cardinael
- Univ Rouen Normandie, FR CNRS 3038, SMS, UR3233, Rouen F-76000, France
| |
Collapse
|
7
|
Cagliero C, Bicchi C, Marengo A, Rubiolo P, Sgorbini B. Gas chromatography of essential oil: State-of-the-art, recent advances, and perspectives. J Sep Sci 2021; 45:94-112. [PMID: 34897986 DOI: 10.1002/jssc.202100681] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 10/02/2021] [Accepted: 10/03/2021] [Indexed: 11/10/2022]
Abstract
This review is an overview of the recent advances of gas chromatography in essential oil analysis; in particular, it focuses on both the new stationary phases and the advanced analytical methods and instrumentations. A paragraph is dedicated to ionic liquids as gas chromatography stationary phases, showing that, thanks to their peculiar selectivity, they can offer a complementary contribution to conventional stationary phases for the analysis of complex essential oils and the separation of critical pairs of components. Strategies to speed-up the analysis time, thus answering to the ever increasing request for routine essential oils quality control, are also discussed. Last but not least, a paragraph is dedicated to recent developments in column miniaturization in particular that based on microelectromechanical-system technology in a perspective of developing micro-gas chromatographic systems to optimize the energy consumption as well as the instrumentation dimensions. A number of applications in the essential oil field is also included.
Collapse
Affiliation(s)
- Cecilia Cagliero
- Dipartimento di Scienza e Tecnologia del Farmaco, Università degli Studi di Torino, Torino, Italy
| | - Carlo Bicchi
- Dipartimento di Scienza e Tecnologia del Farmaco, Università degli Studi di Torino, Torino, Italy
| | - Arianna Marengo
- Dipartimento di Scienza e Tecnologia del Farmaco, Università degli Studi di Torino, Torino, Italy
| | - Patrizia Rubiolo
- Dipartimento di Scienza e Tecnologia del Farmaco, Università degli Studi di Torino, Torino, Italy
| | - Barbara Sgorbini
- Dipartimento di Scienza e Tecnologia del Farmaco, Università degli Studi di Torino, Torino, Italy
| |
Collapse
|
8
|
Davis JJ, Foster SW, Grinias JP. Low-cost and open-source strategies for chemical separations. J Chromatogr A 2021; 1638:461820. [PMID: 33453654 PMCID: PMC7870555 DOI: 10.1016/j.chroma.2020.461820] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 12/12/2020] [Accepted: 12/14/2020] [Indexed: 12/18/2022]
Abstract
In recent years, a trend toward utilizing open access resources for laboratory research has begun. Open-source design strategies for scientific hardware rely upon the use of widely available parts, especially those that can be directly printed using additive manufacturing techniques and electronic components that can be connected to low-cost microcontrollers. Open-source software eliminates the need for expensive commercial licenses and provides the opportunity to design programs for specific needs. In this review, the impact of the "open-source movement" within the field of chemical separations is described, primarily through a comprehensive look at research in this area over the past five years. Topics that are covered include general laboratory equipment, sample preparation techniques, separations-based analysis, detection strategies, electronic system control, and software for data processing. Remaining hurdles and possible opportunities for further adoption of open-source approaches in the context of these separations-related topics are also discussed.
Collapse
Affiliation(s)
- Joshua J Davis
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ 08028, United States
| | - Samuel W Foster
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ 08028, United States
| | - James P Grinias
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ 08028, United States.
| |
Collapse
|
9
|
Donval JP, Guyader V, Boissy E. A simple method for the preparation and injection of gas mixtures into a gas chromatograph using a two-component device. J Chromatogr A 2020; 1631:461579. [PMID: 33035905 DOI: 10.1016/j.chroma.2020.461579] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Revised: 09/18/2020] [Accepted: 09/21/2020] [Indexed: 10/23/2022]
Abstract
Environmental sciences are expanding and are based on standardized and certified calibrations when measurements are required. When a gaseous composition is quantified, commercial standards are used. Here, we report on a two-component device for the preparation and injection of gas mixtures at the appropriate levels of pressure and volume. The two-component calibrator/injector can be used simultaneously or separately depending on the experimental objective but their combination is extremely effective for injecting gas mixtures at low concentrations. The quantity of gas introduced into a gas chromatograph with the injector can be adapted to the sensitivity of the detector or to avoid column overload. The calibrator provides for a large range of gas-mixture concentrations, from ppm to % mol/mol with an error of preparation of around 1% and an accuracy of less than 3%. This device prepares a variety of gas mixtures (hydrogen, methane and dioxide of carbon) which are compared with certified mixtures by means of gas chromatographic measurements. The results show good agreement between prepared and certified mixtures with a maximum difference of 2% which remains within the relative error of commercial standard. In addition, the preparation of dissolved methane at different concentrations in seawater is presented as a direct application of the calibrator.
Collapse
Affiliation(s)
- J P Donval
- Unité des Géosciences Marines Géosciences Marines, Laboratoire Cycles Géochimiques et ressources IFREMER Centre de Brest, Plouzané, France.
| | - V Guyader
- Unité des Géosciences Marines Géosciences Marines, Laboratoire Cycles Géochimiques et ressources IFREMER Centre de Brest, Plouzané, France
| | - E Boissy
- Département Mesures Physiques, INSTITUT UNIVERSITAIRE DE TECHNOLOGIE, Lannion, France
| |
Collapse
|
10
|
Hsieh HC, Kim H. Isomer separation enabled by a micro circulatory gas chromatography system. J Chromatogr A 2020; 1629:461484. [PMID: 32889297 DOI: 10.1016/j.chroma.2020.461484] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Revised: 08/10/2020] [Accepted: 08/12/2020] [Indexed: 11/30/2022]
Abstract
Isomers, holding similar chemical and physical properties, are difficult to separate especially by utilizing a microfabricated gas chromatography system due to limited column lengths mainly imposed by low-pressure (<20 kPa) micropump capability. In this paper, we demonstrated the separation of a pair of structural isomers, isopentane and pentane, in a micro-scale gas chromatography system with a circulatory loop of two 25-cm micro open tubular columns, while operating under a minimal pressure requirement of <10 kPa. The developed micro circulatory gas chromatography (MCGC) system achieved an effective column length of 12.5 meters by circulating the isomer gases for 25 cycles, the longest micro open tubular column length ever reported by any microfabricated GC systems yet.
Collapse
Affiliation(s)
- Hao-Chieh Hsieh
- Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112 United States
| | - Hanseup Kim
- Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112 United States.
| |
Collapse
|
11
|
Ollé EP, Farré-Lladós J, Casals-Terré J. Advancements in Microfabricated Gas Sensors and Microanalytical Tools for the Sensitive and Selective Detection of Odors. SENSORS (BASEL, SWITZERLAND) 2020; 20:E5478. [PMID: 32987904 PMCID: PMC7583964 DOI: 10.3390/s20195478] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Revised: 09/14/2020] [Accepted: 09/21/2020] [Indexed: 12/15/2022]
Abstract
In recent years, advancements in micromachining techniques and nanomaterials have enabled the fabrication of highly sensitive devices for the detection of odorous species. Recent efforts done in the miniaturization of gas sensors have contributed to obtain increasingly compact and portable devices. Besides, the implementation of new nanomaterials in the active layer of these devices is helping to optimize their performance and increase their sensitivity close to humans' olfactory system. Nonetheless, a common concern of general-purpose gas sensors is their lack of selectivity towards multiple analytes. In recent years, advancements in microfabrication techniques and microfluidics have contributed to create new microanalytical tools, which represent a very good alternative to conventional analytical devices and sensor-array systems for the selective detection of odors. Hence, this paper presents a general overview of the recent advancements in microfabricated gas sensors and microanalytical devices for the sensitive and selective detection of volatile organic compounds (VOCs). The working principle of these devices, design requirements, implementation techniques, and the key parameters to optimize their performance are evaluated in this paper. The authors of this work intend to show the potential of combining both solutions in the creation of highly compact, low-cost, and easy-to-deploy platforms for odor monitoring.
Collapse
Affiliation(s)
- Enric Perarnau Ollé
- Department of Mechanical Engineering, Polytechnical University of Catalonia (UPC), MicroTech Lab, Colom street 11, 08222 Terrassa, Spain; (J.F.-L.); (J.C.-T.)
- SEAT S.A., R&D Department in Future Urban Mobility Concepts, A-2, Km 585, 08760 Martorell, Spain
| | - Josep Farré-Lladós
- Department of Mechanical Engineering, Polytechnical University of Catalonia (UPC), MicroTech Lab, Colom street 11, 08222 Terrassa, Spain; (J.F.-L.); (J.C.-T.)
| | - Jasmina Casals-Terré
- Department of Mechanical Engineering, Polytechnical University of Catalonia (UPC), MicroTech Lab, Colom street 11, 08222 Terrassa, Spain; (J.F.-L.); (J.C.-T.)
| |
Collapse
|
12
|
Barauskas D, Dzikaras M, Bieliauskas D, Pelenis D, Vanagas G, Viržonis D. Selective Ultrasonic Gravimetric Sensors Based on Capacitive Micromachined Ultrasound Transducer Structure-A Review. SENSORS (BASEL, SWITZERLAND) 2020; 20:E3554. [PMID: 32585954 PMCID: PMC7349875 DOI: 10.3390/s20123554] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 06/10/2020] [Accepted: 06/20/2020] [Indexed: 11/25/2022]
Abstract
This review paper discusses the advances of the gravimetric detection devices based on capacitive micromachined ultrasound transducers structure. Principles of gravimetric operation and device modeling are reviewed through the presentation of an analytical, one-dimensional model and finite element modeling. Additionally, the most common fabrication techniques, including sacrificial release and wafer bonding, are discussed for advantages for gravimetric sensing. As functional materials are the most important part of the selective gravimetric sensing, the review of different functional material properties and coating and application methods is necessary. Particularly, absorption and desorption mechanisms of functional materials, like methylated polyethyleneimine, with examples of applications for gas sensing and using immune complexes for specific biomolecules detection are reviewed.
Collapse
Affiliation(s)
- Dovydas Barauskas
- Kaunas University of Technology, Panevėžys Institute of Technologies and Business, LT-37164 Panevėžys, Lithuania; (M.D.); (D.B.); (D.P.); (G.V.)
| | | | | | | | | | - Darius Viržonis
- Kaunas University of Technology, Panevėžys Institute of Technologies and Business, LT-37164 Panevėžys, Lithuania; (M.D.); (D.B.); (D.P.); (G.V.)
| |
Collapse
|
13
|
Mametov R, Ratiu IA, Monedeiro F, Ligor T, Buszewski B. Evolution and Evaluation of GC Columns. Crit Rev Anal Chem 2019; 51:150-173. [PMID: 31820658 DOI: 10.1080/10408347.2019.1699013] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
A chromatographic column is the fundamental element required for gas-chromatographic analysis. The separation of components coming from complex mixtures, prior to their detection was leading to a prominent revolution in different areas of science. Moreover, current advances in gas chromatographic (GC) columns technology and development have been providing almost unlimited possibilities for analysis employing diverse matrices. We aim through this review article to describe the evolution of chromatographic columns, by pointing the most important stages, as well as the new trends and future perspectives predicted for the new generation of GC columns. Furthermore, it was in our scope to present the main fundamentals regarding the theoretical relationships that describe the chromatographic separation, to introduce concepts related to columns selection in accordance with the required application as well as to discuss the available evaluation parameters for columns efficiency. Consequently, the early stages of first columns preparation up to the development of GC capillary columns used nowadays, together with examples of their applications are also reported and described in detail.
Collapse
Affiliation(s)
- Radik Mametov
- Department of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University, Toruń, Poland.,Interdisciplinary Centre for Modern Technologies, Nicolaus Copernicus University, Toruń, Poland
| | - Ileana-Andreea Ratiu
- Department of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University, Toruń, Poland.,Interdisciplinary Centre for Modern Technologies, Nicolaus Copernicus University, Toruń, Poland.,Faculty of Chemistry and Chemical Engineering, Babeş-Bolyai University, Cluj-Napoca, Romania
| | - Fernanda Monedeiro
- Interdisciplinary Centre for Modern Technologies, Nicolaus Copernicus University, Toruń, Poland
| | - Tomasz Ligor
- Department of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University, Toruń, Poland.,Interdisciplinary Centre for Modern Technologies, Nicolaus Copernicus University, Toruń, Poland
| | - Bogusław Buszewski
- Department of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University, Toruń, Poland.,Interdisciplinary Centre for Modern Technologies, Nicolaus Copernicus University, Toruń, Poland
| |
Collapse
|
14
|
Development of Open-Tubular-Type Micro Gas Chromatography Column with Bump Structures. SENSORS 2019; 19:s19173706. [PMID: 31455012 PMCID: PMC6749250 DOI: 10.3390/s19173706] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 08/14/2019] [Accepted: 08/23/2019] [Indexed: 12/18/2022]
Abstract
Gas chromatography (GC) is the chemical analysis technique most widely used to separate and identify gas components, and it has been extensively applied in various gas analysis fields such as non-invasive medical diagnoses, indoor air quality monitoring, and outdoor environmental monitoring. Micro-electro-mechanical systems (MEMS)-based GC columns are essential for miniaturizing an integrated gas analysis system (Micro GC system). This study reports an open-tubular-type micro GC (μ-GC) column with internal bump structures (bump structure μ-GC column) that substantially increase the interaction between the gas mixture and a stationary phase. The developed bump structure μ-GC column, which was fabricated on a 2 cm × 2 cm μ-GC chip and coated with a non-polar stationary phase, is 1.5 m-long, 150 μm-wide, and 400 μm-deep. It has an internal microfluidic channel in which the bumps, which are 150 μm diameter half-circles, are alternatingly disposed to face each other on the surface of the microchannel. The fabricated bump structure μ-GC column yielded a height-equivalent-to-a-theoretical-plate (HETP) of 0.009 cm (11,110 plates/m) at an optimal carrier gas velocity of 17 cm/s. The mechanically robust bump structure μ-GC column proposed in this study achieved higher separation efficiency than a commercially available GC column and a typical μ-GC column with internal post structures classified as a semi-packed-type column. The experimental results demonstrate that the developed bump structure μ-GC column can separate a gas mixture completely, with excellent separation resolution for formaldehyde, benzene, toluene, ethylbenzene, and xylene mixture, under programmed operating temperatures.
Collapse
|
15
|
Li X, Dai Y, Row KH. Preparation of two-dimensional magnetic molecularly imprinted polymers based on boron nitride and a deep eutectic solvent for the selective recognition of flavonoids. Analyst 2019; 144:1777-1788. [DOI: 10.1039/c8an02258e] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Two-dimensional (2D) boron nitride (BN) were developed as a 2D scaffold material in preparation of magnetic molecularly imprinted polymers (MMIPs).
Collapse
Affiliation(s)
- Xiaoxia Li
- Department of Chemistry and Chemical Engineering
- Inha University
- Incheon 402-751
- Korea
| | - Yunliang Dai
- Department of Chemistry and Chemical Engineering
- Inha University
- Incheon 402-751
- Korea
| | - Kyung Ho Row
- Department of Chemistry and Chemical Engineering
- Inha University
- Incheon 402-751
- Korea
| |
Collapse
|
16
|
Regmi BP, Agah M. Micro Gas Chromatography: An Overview of Critical Components and Their Integration. Anal Chem 2018; 90:13133-13150. [DOI: 10.1021/acs.analchem.8b01461] [Citation(s) in RCA: 59] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- Bishnu P. Regmi
- VT MEMS Lab, Bradley Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Masoud Agah
- VT MEMS Lab, Bradley Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| |
Collapse
|
17
|
Chappuis TH, Pham Ho BA, Ceillier M, Ricoul F, Alessio M, Beche JF, Corne C, Besson G, Vial J, Thiébaut D, Bourlon B. Miniaturization of breath sampling with silicon chip: application to volatile tobacco markers tracking. J Breath Res 2018; 12:046011. [PMID: 30008462 DOI: 10.1088/1752-7163/aad384] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
This work presents the performances of silicon micro-preconcentrators chips for breath sampling. The silicon chips were coupled to a handheld battery powered system for breath sampling and direct injection in a laboratory gas chromatography mass spectrometry system through thermal desorption (TD). Performances of micro-preconcentrators were first compared to commercial TD for benzene trapping. Similar chromatographic peaks after gas chromatographic separation were observed while the volume of sample needed was reduced by a factor of 5. Repeatability and day to day variability of the micro-preconcentrators were then studied for a 500 ppb synthetic model mixture injected three times a day four days in a row: 8% and 12% were measured respectively. Micro-preconcentrator to micro-preconcentrator variability was not significant compared to day to day variability. In addition, micro-preconcentrators were tested for breath samples collected in Tedlar® bags. Three analyses of the same breath sample displayed relative standard deviations values below 16% for eight of the ten most intense peaks. Finally, the performances of micro-preconcentrators for breath sampling on a single expiration were illustrated with the example of volatile tobacco markers tracking. The signals of three smoking markers in breath, benzene, 2,5-dimethylfuran, and toluene were studied. Concentrations of benzene and toluene were found to be 10 to 100 higher in the breath of smokers. 2,5-dimethylfuran was only found in the breath of smokers. The elimination kinetics of the markers were followed as well during 4 h: a fast decrease of the signal of the three markers in breath was observed 20 min after smoking in good agreement with what is described in the literature. Those results demonstrate the efficiency of silicon chips for breath sampling, compared to the state of the art techniques. Thanks to miniaturization and lower sample volumes needed, micro-preconcentrators could be in the future a key technology towards portable breath sampling and analysis.
Collapse
Affiliation(s)
- Thomas Hector Chappuis
- Univ. Grenoble Alpes, CEA, LETI, MINATEC Campus, F-38000 Grenoble, France. UMR 8231 CBI, LSABM, ESPCI Paris-CNRS, PSL Institute, Paris, France
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Ghosh A, Vilorio CR, Hawkins AR, Lee ML. Microchip gas chromatography columns, interfacing and performance. Talanta 2018; 188:463-492. [PMID: 30029402 DOI: 10.1016/j.talanta.2018.04.088] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Revised: 04/25/2018] [Accepted: 04/26/2018] [Indexed: 11/30/2022]
Abstract
Almost four decades of investigations have opened up many avenues to explore the production and utilization of planar (i.e., microchip) gas chromatographic columns. However, there remain many practical constraints that limit their widespread commercialization and use. The main challenges arise from non-ideal column geometries, dead volume issues and inadequate interfacing technologies, which all affect both column performance and range of applications. This review reflects back over the years on the extensive developments in the field, with the goal to stimulate future creative approaches and increased efforts to accelerate microchip gas chromatography development toward reaching its full potential.
Collapse
Affiliation(s)
- Abhijit Ghosh
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA
| | - Carlos R Vilorio
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT 84602, USA
| | - Aaron R Hawkins
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT 84602, USA
| | - Milton L Lee
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA.
| |
Collapse
|
19
|
Li X, Row KH. Application of novel ternary deep eutectic solvents as a functional monomer in molecularly imprinted polymers for purification of levofloxacin. J Chromatogr B Analyt Technol Biomed Life Sci 2017; 1068-1069:56-63. [PMID: 29031109 DOI: 10.1016/j.jchromb.2017.10.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2017] [Revised: 10/02/2017] [Accepted: 10/05/2017] [Indexed: 01/06/2023]
Abstract
A series of ecofriendly ternary deep eutectic solvents (DESs) with different molar ratios were prepared as candidate functional monomers. Three of the optimal ternary DESs as functional monomers were applied to the preparation of molecularly imprinted polymers (MIPs). After synthesis, the proposed polymers were characterized by elemental analysis (EA), scanning electron microscopy (SEM), thermogravimetric analysis (TGA), Brunauer-Emmett-Teller surface area measurements (BET) and Fourier transform infrared spectroscopy (FT-IR). These MIPs based on ternary DESs with different molar ratios exhibited different absorption capacities of levofloxacin. A sample of levofloxacin (500ng) was dissolved in a millet extractive (10mL). All MIPs were used as SPE adsorbents to purify the extracts. According to characterization result, the ternary DES-3 (1:3:1.5) was joined in the synthetic process of MIP-1. The green ternary DES-3-based MIPs had the best selectivity recovery for levofloxacin (91.4%) from the millet extractive. The best selectivity of MIP-1 was attributed to the novel monomer (ternary DES) in the preparation of the materials. Overall, ternary DES-based MIPs have potential applications as media in many research areas.
Collapse
Affiliation(s)
- Xiaoxia Li
- Department of Chemistry and Chemical Engineering, Inha University, Incheon 402-751, Republic of Korea
| | - Kyung Ho Row
- Department of Chemistry and Chemical Engineering, Inha University, Incheon 402-751, Republic of Korea.
| |
Collapse
|
20
|
Li X, Choi J, Ahn WS, Row KH. Preparation and Application of Porous Materials based on Deep Eutectic Solvents. Crit Rev Anal Chem 2017; 48:73-85. [DOI: 10.1080/10408347.2017.1383881] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Affiliation(s)
- Xiaoxia Li
- Department of Chemistry and Chemical Engineering, Inha University, Incheon, Korea
| | - Jinsub Choi
- Department of Chemistry and Chemical Engineering, Inha University, Incheon, Korea
| | - Wha-Seung Ahn
- Department of Chemistry and Chemical Engineering, Inha University, Incheon, Korea
| | - Kyung Ho Row
- Department of Chemistry and Chemical Engineering, Inha University, Incheon, Korea
| |
Collapse
|
21
|
Schulze F, Gao X, Virzonis D, Damiati S, Schneider MR, Kodzius R. Air Quality Effects on Human Health and Approaches for Its Assessment through Microfluidic Chips. Genes (Basel) 2017; 8:E244. [PMID: 28953246 PMCID: PMC5664094 DOI: 10.3390/genes8100244] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2017] [Revised: 09/11/2017] [Accepted: 09/20/2017] [Indexed: 01/16/2023] Open
Abstract
Air quality depends on the various gases and particles present in it. Both natural phenomena and human activities affect the cleanliness of air. In the last decade, many countries experienced an unprecedented industrial growth, resulting in changing air quality values, and correspondingly, affecting our life quality. Air quality can be accessed by employing microchips that qualitatively and quantitatively determine the present gases and dust particles. The so-called particular matter 2.5 (PM2.5) values are of high importance, as such small particles can penetrate the human lung barrier and enter the blood system. There are cancer cases related to many air pollutants, and especially to PM2.5, contributing to exploding costs within the healthcare system. We focus on various current and potential future air pollutants, and propose solutions on how to protect our health against such dangerous substances. Recent developments in the Organ-on-Chip (OoC) technology can be used to study air pollution as well. OoC allows determination of pollutant toxicity and speeds up the development of novel pharmaceutical drugs.
Collapse
Affiliation(s)
- Frank Schulze
- German Federal Institute for Risk Assessment (BfR), German Centre for the Protection of Laboratory Animals (Bf3R), 10589 Berlin, Germany.
| | - Xinghua Gao
- iSmart, Materials Genome Institute, Shanghai University (SHU), Shanghai 201800, China.
| | - Darius Virzonis
- Department of Electrical Engineering, Kaunas University of Technology, 35212 Panevezys, Lithuania.
| | - Samar Damiati
- Department of Biochemistry, King Abdulaziz University, Jeddah 80203, Saudi Arabia.
- Institute for Synthetic Bioarchitecture, Department of Nanobiotechnology, University of Natural Resources and Life Sciences, 1190 Vienna, Austria.
| | - Marlon R Schneider
- German Federal Institute for Risk Assessment (BfR), German Centre for the Protection of Laboratory Animals (Bf3R), 10589 Berlin, Germany.
| | - Rimantas Kodzius
- German Federal Institute for Risk Assessment (BfR), German Centre for the Protection of Laboratory Animals (Bf3R), 10589 Berlin, Germany.
- iSmart, Materials Genome Institute, Shanghai University (SHU), Shanghai 201800, China.
- Mathematics and Natural Sciences Department, The American University of Iraq, Sulaimani, Sulaymaniyah 46001, Iraq.
| |
Collapse
|
22
|
Achyuthan KE, Harper JC, Manginell RP, Moorman MW. Volatile Metabolites Emission by In Vivo Microalgae-An Overlooked Opportunity? Metabolites 2017; 7:E39. [PMID: 28788107 PMCID: PMC5618324 DOI: 10.3390/metabo7030039] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2017] [Revised: 07/19/2017] [Accepted: 07/25/2017] [Indexed: 01/04/2023] Open
Abstract
Fragrances and malodors are ubiquitous in the environment, arising from natural and artificial processes, by the generation of volatile organic compounds (VOCs). Although VOCs constitute only a fraction of the metabolites produced by an organism, the detection of VOCs has a broad range of civilian, industrial, military, medical, and national security applications. The VOC metabolic profile of an organism has been referred to as its 'volatilome' (or 'volatome') and the study of volatilome/volatome is characterized as 'volatilomics', a relatively new category in the 'omics' arena. There is considerable literature on VOCs extracted destructively from microalgae for applications such as food, natural products chemistry, and biofuels. VOC emissions from living (in vivo) microalgae too are being increasingly appreciated as potential real-time indicators of the organism's state of health (SoH) along with their contributions to the environment and ecology. This review summarizes VOC emissions from in vivo microalgae; tools and techniques for the collection, storage, transport, detection, and pattern analysis of VOC emissions; linking certain VOCs to biosynthetic/metabolic pathways; and the role of VOCs in microalgae growth, infochemical activities, predator-prey interactions, and general SoH.
Collapse
Affiliation(s)
- Komandoor E Achyuthan
- Nano and Microsensors Department, Sandia National Laboratories, Albuquerque, NM 87185, USA.
| | - Jason C Harper
- Bioenergy and Defense Technology Department, Sandia National Laboratories, Albuquerque, NM 87185, USA.
| | - Ronald P Manginell
- Nano and Microsensors Department, Sandia National Laboratories, Albuquerque, NM 87185, USA.
| | - Matthew W Moorman
- Nano and Microsensors Department, Sandia National Laboratories, Albuquerque, NM 87185, USA.
| |
Collapse
|
23
|
Simultaneous on-line monitoring of propofol and sevoflurane in balanced anesthesia by direct resistive heating gas chromatography. J Chromatogr A 2017; 1506:93-100. [DOI: 10.1016/j.chroma.2017.05.001] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Revised: 04/28/2017] [Accepted: 05/01/2017] [Indexed: 11/21/2022]
|