1
|
Castro AS, de Azevedo LS, Rodrigues CHP, Patelli ACC, Bruni AT, de Oliveira MF. Use of voltammetric and chemometric tools to develop a sensor in forensic chemistry. TALANTA OPEN 2022. [DOI: 10.1016/j.talo.2021.100079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
2
|
Carby-Robinson D, Dalsgaard PW, Mollerup CB, Linnet K, Rasmussen BS. Cocaine profiling method retrospectively developed with nontargeted discovery of markers using liquid chromatography with time-of-flight mass spectrometry data. Drug Test Anal 2021; 14:462-473. [PMID: 34265168 PMCID: PMC9291609 DOI: 10.1002/dta.3130] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Revised: 07/10/2021] [Accepted: 07/12/2021] [Indexed: 01/28/2023]
Abstract
Illicit drug profiling performed by forensic laboratories assists law enforcement agencies through providing information about chemical and/or physical characteristics of seized specimens. In this article, a model was developed for the comparison of seized cocaine based on retrospective analysis of data generated from ultrahigh performance liquid chromatography with time‐of‐flight mass spectrometry (UHPLC‐TOF‐MS) comprehensive drug screening. A nontargeted approach to discover target compounds was employed, which generated 53 potential markers using data from cocaine positive samples. Twelve marker compounds were selected for the development of the final profiling model. The selection included a mixture of commonly used cocaine profiling targets and other cocaine‐related compounds. Combinations of pretreatments and comparison metrics were assessed using receiver operating characteristic curves to determine the combination with the best discrimination between linked and unlinked populations. Using data from 382 linked and 34,519 unlinked distances, a classification model was developed using a combination of the standardization and normalization transformations with Canberra distance, resulting in a linked cut‐off with a 0.5% false positive rate. The present study demonstrates the applicability of retrospectively developing a cocaine profiling model using data generated from UHPLC‐TOF‐MS nontargeted drug screening without pre‐existing information about cocaine impurities. The developed workflow was not specific to cocaine and thus could potentially be applied to any seized drug in which there are both sufficient data and impurities present.
Collapse
Affiliation(s)
- Daniel Carby-Robinson
- Section of Forensic Chemistry, Department of Forensic Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Petur Weihe Dalsgaard
- Section of Forensic Chemistry, Department of Forensic Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Christian Brinch Mollerup
- Section of Forensic Chemistry, Department of Forensic Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Kristian Linnet
- Section of Forensic Chemistry, Department of Forensic Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Brian Schou Rasmussen
- Section of Forensic Chemistry, Department of Forensic Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
3
|
Chen X, Wu X, Luan T, Jiang R, Ouyang G. Sample preparation and instrumental methods for illicit drugs in environmental and biological samples: A review. J Chromatogr A 2021; 1640:461961. [PMID: 33582515 DOI: 10.1016/j.chroma.2021.461961] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2020] [Revised: 01/28/2021] [Accepted: 01/28/2021] [Indexed: 12/13/2022]
Abstract
Detection of illicit drugs in the environmental samples has been challenged as the consumption increases globally. Current review examines the recent developments and applications of sample preparation techniques for illicit drugs in solid, liquid, and gas samples. For solid samples, traditional sample preparation methods such as liquid-phase extraction, solid-phase extraction, and the ones with external energy including microwave-assisted, ultrasonic-assisted, and pressurized liquid extraction were commonly used. The sample preparation methods mainly applied for liquid samples were microextraction techniques including solid-phase microextraction, microextraction by packed sorbent, dispersive solid-phase extraction, dispersive liquid-liquid microextraction, hollow fiber-based liquid-phase microextraction, and so on. Capillary microextraction of volatiles and airborne particulate sampling were primarily utilized to extract illicit drugs from gas samples. Besides, the paper introduced recently developed instrumental techniques applied to detect illicit drugs. Liquid chromatograph mass spectrometry and gas chromatograph mass spectrometry were the most widely used methods for illicit drugs samples. In addition, the development of ambient mass spectrometry techniques, such as desorption electrospray ionization mass spectrometry and paper spray mass spectrometry, created potential for rapid in-situ analysis.
Collapse
Affiliation(s)
- Xinlv Chen
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou 511443, China
| | - Xinyan Wu
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou 511443, China
| | - Tiangang Luan
- Guangdong Provincial Key Laboratory of Psychoactive Substances Monitoring and safety, Institute of Environmental and Ecological Engineering, Guangdong University of Technology, 100 Waihuanxi Road, Guangzhou 510006, China
| | - Ruifen Jiang
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou 511443, China.
| | - Gangfeng Ouyang
- KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China; Guangdong Provincial Key Laboratory of Emergency Test for Dangerous Chemicals, Guangdong Institute of Analysis (China National Analytical Center Guangzhou), Guangzhou, 510070, China; Chemistry College, Center of Advanced Analysis and Gene Sequencing, Zhengzhou University, Kexue Avenue 100, Zhengzhou 450001, China.
| |
Collapse
|
4
|
Grothe RA, Lobato A, Mounssef B, Tasić N, Braga AAC, Maldaner AO, Aldous L, Paixão TRLC, Gonçalves LM. Electroanalytical profiling of cocaine samples by means of an electropolymerized molecularly imprinted polymer using benzocaine as the template molecule. Analyst 2021; 146:1747-1759. [DOI: 10.1039/d0an02274h] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Cocaine samples were ‘finger-printed’ using e-MIPs, constructed on the surface of portable SPCEs. The SWV data with suitable chemometric analysis provides valuable information about the drugs’ provenience which is crucial to tackle drug traffic.
Collapse
Affiliation(s)
- Renata A. Grothe
- Departamento de Química Fundamental
- Instituto de Química
- Universidade de São Paulo (USP)
- São Paulo – SP
- Brazil
| | - Alnilan Lobato
- Departamento de Química Fundamental
- Instituto de Química
- Universidade de São Paulo (USP)
- São Paulo – SP
- Brazil
| | - Bassim Mounssef
- Departamento de Química Fundamental
- Instituto de Química
- Universidade de São Paulo (USP)
- São Paulo – SP
- Brazil
| | - Nikola Tasić
- Departamento de Química Fundamental
- Instituto de Química
- Universidade de São Paulo (USP)
- São Paulo – SP
- Brazil
| | - Ataualpa A. C. Braga
- Departamento de Química Fundamental
- Instituto de Química
- Universidade de São Paulo (USP)
- São Paulo – SP
- Brazil
| | - Adriano O. Maldaner
- Instituto Nacional de Criminalística
- Polícia Federal Brasileira (PFB)
- Asa Sul, Brasília – DF
- Brazil
| | - Leigh Aldous
- Department of Chemistry
- King's College of London
- London
- UK
| | - Thiago R. L. C. Paixão
- Departamento de Química Fundamental
- Instituto de Química
- Universidade de São Paulo (USP)
- São Paulo – SP
- Brazil
| | - Luís Moreira Gonçalves
- Departamento de Química Fundamental
- Instituto de Química
- Universidade de São Paulo (USP)
- São Paulo – SP
- Brazil
| |
Collapse
|
5
|
Jones NS, Comparin JH. Interpol review of controlled substances 2016-2019. Forensic Sci Int Synerg 2020; 2:608-669. [PMID: 33385148 PMCID: PMC7770462 DOI: 10.1016/j.fsisyn.2020.01.019] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 01/23/2020] [Indexed: 12/14/2022]
Abstract
This review paper covers the forensic-relevant literature in controlled substances from 2016 to 2019 as a part of the 19th Interpol International Forensic Science Managers Symposium. The review papers are also available at the Interpol website at: https://www.interpol.int/content/download/14458/file/Interpol%20Review%20Papers%202019.pdf.
Collapse
Affiliation(s)
- Nicole S. Jones
- RTI International, Applied Justice Research Division, Center for Forensic Sciences, 3040 E. Cornwallis Road, Research Triangle Park, NC, 22709-2194, USA
| | - Jeffrey H. Comparin
- United States Drug Enforcement Administration, Special Testing and Research Laboratory, USA
| |
Collapse
|
6
|
Peck Y, Clough AR, Culshaw PN, Liddell MJ. Multi-drug cocktails: Impurities in commonly used illicit drugs seized by police in Queensland, Australia. Drug Alcohol Depend 2019; 201:49-57. [PMID: 31181437 DOI: 10.1016/j.drugalcdep.2019.03.019] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2018] [Revised: 03/21/2019] [Accepted: 03/26/2019] [Indexed: 02/07/2023]
Abstract
BACKGROUND Impurities in commonly used illicit drugs raise concerns for unwitting consumers when pharmacologically active adulterants, especially new psychoactive substances (NPS), are used. This study examines impurities detected in illicit drugs seized in one Australian jurisdiction. METHODS Queensland Health Forensic and Scientific Services provided analytical data. Data described the chemical composition of 9346 samples of 11 illicit drugs seized by police during 2015-2016. Impurities present in primary drugs were summarized and tabulated. A systematic search for published evidence reporting similar analyses was conducted. RESULTS Methamphetamine was the primary drug in 6608 samples, followed by MDMA (1232 samples) and cocaine (516 samples). Purity of primary drugs ranged from ∼30% for cocaine, 2-CB and GHB to >90% for THC, methamphetamine, heroin and MDMA. Methamphetamine and MDMA contained the largest variety of impurities: 22 and 18 variants, respectively. Drug adulteration patterns were broadly similar to those found elsewhere, including NPS, but in some primary drugs impurities were found which had not been reported elsewhere. Psychostimulants were adulterated with each other. Levamisole was a common impurity in cocaine. Psychedelics were adulterated with methamphetamine and NPS. Opioids were quite pure, but some samples contained methamphetamine and synthetic opioids. CONCLUSIONS Impurities detected were mostly pharmacologically active adulterants probably added to enhance desired effects or for active bulking. Given the designer nature of these drug cocktails, the effects of the adulterated drugs on users from possible complex multi-drug interactions is unpredictable. Awareness-raising among users, research into complex multi-drug effects and ongoing monitoring is required.
Collapse
Affiliation(s)
- Yoshimi Peck
- College of Science and Engineering, James Cook University, 14-88 McGregor Road, Smithfield, Queensland, Australia.
| | - Alan R Clough
- College of Public Health, Medical and Vet Sciences, James Cook University, 14-88 McGregor Road, Smithfield, Queensland, Australia
| | - Peter N Culshaw
- Forensic Chemistry, Forensic and Scientific Services, Queensland Health, 39 Kessels Road, Coopers Plains, 4108, Queensland, Australia
| | - Michael J Liddell
- College of Science and Engineering, James Cook University, 14-88 McGregor Road, Smithfield, Queensland, Australia
| |
Collapse
|
7
|
Hespanhol MC, Pasquini C, Maldaner AO. Evaluation of a low-cost portable near-infrared spectrophotometer for in situ cocaine profiling. Talanta 2019; 200:553-561. [PMID: 31036222 DOI: 10.1016/j.talanta.2019.03.091] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2019] [Revised: 03/24/2019] [Accepted: 03/25/2019] [Indexed: 11/26/2022]
Abstract
The potential of a low-cost (∼US$ 1000) portable near-infrared (NIR) spectrophotometer for in situ characterization of seized cocaine samples was evaluated. A set of 240 samples of cocaine seized in several regions and cities across Brazil by its federal police was employed in this study. These samples were previously analyzed by chromatography at the Forensic Chemistry Laboratory of the National Institute of Criminalistics in Brasília-DF for the contents of several constituents to chemically characterize the samples. A low-cost NanoNIR spectrophotometer (Texas instruments) was used to acquire the NIR spectra of the samples in the range 900-1700 nm. The spectra set was treated by the second derivative to construct and validate multivariate regression (Partial Least Square - PLS) and classification (software independent modeling of class analogy - SIMCA) models aiming to characterize the samples. Consequently, an informative toll for objective decision making could be used by the police agents to produce immediate answers to forensic questions raised at the point of seizing. Among those questions the most relevant are: does the seized sample contain cocaine? what is the cocaine form? what is its content? is the sample adulterated and/or diluted? what is the content of adulterant? is the sample significantly adulterated and/or diluted? what is the degree of oxidation of the cocaine? The results of this work allow to propose a NIR/chemometrics based analytical protocol providing fast answers to these questions with satisfactory confidence level for the purpose of reliably screen the seized samples.
Collapse
Affiliation(s)
- Maria C Hespanhol
- Group of Analysis and Education for Sustainability (GAES), Chemistry Department, Federal University of Viçosa (UFV), Viçosa, MG, 36570-900, Brazil.
| | - Celio Pasquini
- Chemistry Institute, State University of Campinas - UNICAMP, Rua Monteiro Lobato, 290, Campinas, SP, 13083-862, Brazil
| | - Adriano O Maldaner
- National Institute of Criminalistics, Brazilian Federal Police, SAIS Quadra 07 Lote 23, Brasília, DF, 70610-200, Brazil
| |
Collapse
|
8
|
Moreira RC, Costa BMC, Marra MC, Santana MHP, Maldaner AO, Botelho ÉD, Paixão TRLC, Richter EM, Coltro WKT. Screening of seized cocaine samples using electrophoresis microchips with integrated contactless conductivity detection. Electrophoresis 2018; 39:2188-2194. [PMID: 29947145 DOI: 10.1002/elps.201800137] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2018] [Revised: 06/09/2018] [Accepted: 06/10/2018] [Indexed: 11/11/2022]
Abstract
This study describes the development of a new analytical method for the separation and detection of cocaine (COC) and its adulterants, or cutting agents, using microchip electrophoresis (ME) devices coupled with capacitively coupled contactless conductivity detection (C4 D). All the experiments were carried out using a glass commercial ME device containing two pairs of integrated sensing electrodes. The running buffer composed of 20 mmol/L amino-2-(hydroxymethyl) propane-1,3-diol and 10 mmol/L 3,4-dimethoxycinnamic acid provided the best separation conditions for COC and its adulterants with baseline resolution (R > 1.6), separation efficiencies ranging from (2.9 ± 0.1) to (3.2 ± 0.2) × 105 plates/m, and estimated LOD values between 40 and 150 μmol/L. The quantification of COC was successfully performed in four samples seized by the Brazilian Federal Police Department and all predicted values agree with values estimated by the reference method. Some other interfering species were detected in the seized samples during the screening procedure on ME-C4 D devices. While lidocaine was detected in sample 3, the presence of levamisole was observed in samples 2 and 4. However, their concentrations were estimated to be below the LOQ. ME-C4 D devices have proved to be quite efficient for the identification and quantification of COC with errors lower than 10% when compared to the data obtained by a reference method. The approach herein reported offers great potential to be used for on-site COC screening in seized samples.
Collapse
Affiliation(s)
| | - Brenda M C Costa
- Instituto de Química, Universidade Federal de Uberlândia, Uberlândia, MG, Brazil
| | - Mariana C Marra
- Instituto de Química, Universidade Federal de Uberlândia, Uberlândia, MG, Brazil
| | - Mario H P Santana
- Instituto Nacional de Criminalística, Polícia Federal Brasileira, Brasília, DF, Brazil
| | - Adriano O Maldaner
- Unidade Técnico-Científica, Superintendência Regional da Polícia Federal em MG, Uberlândia, MG, Brazil
| | - Élvio D Botelho
- Unidade Técnico-Científica, Superintendência Regional da Polícia Federal em MG, Uberlândia, MG, Brazil
| | | | | | - Wendell K T Coltro
- Instituto de Química, Universidade Federal de Goiás, Goiânia, GO, Brazil
| |
Collapse
|