1
|
Wharton LK, Anumba DOC. Techniques for detecting cervical remodeling as a predictor for spontaneous preterm birth: current evidence and future research avenues in patients with multiple pregnancies. J Matern Fetal Neonatal Med 2023; 36:2262081. [PMID: 37778754 DOI: 10.1080/14767058.2023.2262081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2023] [Accepted: 09/18/2023] [Indexed: 10/03/2023]
Abstract
BACKGROUND Spontaneous preterm birth occurs more frequently in multiple pregnancies. This syndrome has multiple triggers that result in a unified downstream pathway of cervical remodeling, uterine activity, and progressive cervical dilatation. Whilst the triggers for labor in multiple pregnancy may be different from singletons, the downstream changes will be the same. Identifying patients at risk of preterm birth is a priority as interventions to delay delivery and optimize the fetus can be initiated. Methods for screening for risk of preterm birth which focus on the detection of cervical remodeling may therefore have potential in this population. METHODS This review explores the evidence for the predictive utility for preterm birth of several published techniques that assess the physical, biomechanical, and optical properties of the cervix, with a focus on those which have been studied in multiple pregnancies and highlighting targets for future research in this population. RESULTS Fifteen techniques are discussed which assess the physical, biomechanical, and optical properties of the cervix in pregnancy. Of these, only three techniques that evaluated the predictive accuracy of a technique in patients with multiple pregnancies were identified: uterocervical angle, cervical consistency index, and cervical elastography. Of these, measurement of the uterocervical angle has the strongest evidence. Several techniques have shown predictive potential in singleton pregnancies, but have not yet been studied in multiple pregnancies, which would be a logical expansion of research. CONCLUSION Research on techniques with predictive utility for PTB in patients with multiple pregnancies is limited but should be a research priority. Overall, the theory supports the investigation of cervical remodeling as a predictor of PTB, and there are numerous techniques in development that may have potential in this field.
Collapse
Affiliation(s)
- L K Wharton
- Academic Unit of Reproductive and Developmental Medicine, Faculty of Medicine Dentistry and Health, The University of Sheffield, Sheffield, UK
| | - D O C Anumba
- Academic Unit of Reproductive and Developmental Medicine, Faculty of Medicine Dentistry and Health, The University of Sheffield, Sheffield, UK
| |
Collapse
|
2
|
Yoshida K. Bioengineering and the cervix: The past, current, and future for addressing preterm birth. Curr Res Physiol 2023; 6:100107. [PMID: 38107784 PMCID: PMC10724223 DOI: 10.1016/j.crphys.2023.100107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 08/23/2023] [Accepted: 09/20/2023] [Indexed: 12/19/2023] Open
Abstract
The uterine cervix plays two important but opposing roles during pregnancy - as a mechanical barrier that maintains the fetus for nine months and as a compliant structure that dilates to allow for the delivery of a baby. In some pregnancies, however, the cervix softens and dilates prematurely, leading to preterm birth. Bioengineers have addressed and continue to address the lack of reduction in preterm birth rates by developing novel technologies to diagnose, prevent, and understand premature cervical remodeling. This article highlights these existing and emerging technologies and concludes with open areas of research related to the cervix and preterm birth that bioengineers are currently well-positioned to address.
Collapse
Affiliation(s)
- Kyoko Yoshida
- Department of Biomedical Engineering, University of Minnesota, 7-105 Nils Hasselmo Hall, 312 Church Street SE, Minneapolis, MN, 55455, USA
| |
Collapse
|
3
|
Masson LE, O’Brien CM, Gautam R, Thomas G, Slaughter JC, Goldberg M, Bennett K, Herington J, Reese J, Elsamadicy E, Newton JM, Mahadevan-Jansen A. In vivo Raman spectroscopy monitors cervical change during labor. Am J Obstet Gynecol 2022; 227:275.e1-275.e14. [PMID: 35189092 PMCID: PMC9308703 DOI: 10.1016/j.ajog.2022.02.019] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 02/09/2022] [Accepted: 02/15/2022] [Indexed: 11/01/2022]
Abstract
BACKGROUND Biochemical cervical change during labor is not well understood, in part, because of a dearth of technologies capable of safely probing the pregnant cervix in vivo. The need for such a technology is 2-fold: (1) to gain a mechanistic understanding of the cervical ripening and dilation process and (2) to provide an objective method for evaluating the cervical state to guide clinical decision-making. Raman spectroscopy demonstrates the potential to meet this need, as it is a noninvasive optical technique that can sensitively detect alterations in tissue components, such as extracellular matrix proteins, lipids, nucleic acids, and blood, which have been previously established to change during the cervical remodeling process. OBJECTIVE We sought to demonstrate that Raman spectroscopy can longitudinally monitor biochemical changes in the laboring cervix to identify spectral markers of impending parturition. STUDY DESIGN Overall, 30 pregnant participants undergoing either spontaneous or induced labor were recruited. The Raman spectra were acquired in vivo at 4-hour intervals throughout labor until rupture of membranes using a Raman system with a fiber-optic probe. Linear mixed-effects models were used to determine significant (P<.05) changes in peak intensities or peak ratios as a function of time to delivery in the study population. A nonnegative least-squares biochemical model was used to extract the changing contributions of specific molecule classes over time. RESULTS We detected multiple biochemical changes during labor, including (1) significant decreases in Raman spectral features associated with collagen and other extracellular matrix proteins (P=.0054) attributed to collagen dispersion, (2) an increase in spectral features associated with blood (P=.0372), and (3) an increase in features indicative of lipid-based molecules (P=.0273). The nonnegative least-squares model revealed a decrease in collagen contribution with time to delivery, an increase in blood contribution, and a change in lipid contribution. CONCLUSION Our findings have demonstrated that in vivo Raman spectroscopy is sensitive to multiple biochemical remodeling changes in the cervix during labor. Furthermore, in vivo Raman spectroscopy may be a valuable noninvasive tool for objectively evaluating the cervix to potentially guide clinical management of labor.
Collapse
|
4
|
Anumba DOC, Stern V, Healey JT, Dixon S, Brown BH. Value of cervical electrical impedance spectroscopy to predict spontaneous preterm delivery in asymptomatic women: the ECCLIPPx prospective cohort study. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2021; 58:293-302. [PMID: 32798253 DOI: 10.1002/uog.22180] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2020] [Revised: 07/30/2020] [Accepted: 08/03/2020] [Indexed: 06/11/2023]
Abstract
OBJECTIVES Preterm birth (PTB) accounts for two-thirds of deaths of structurally normal babies and is associated with substantial lifetime healthcare costs. Prevention of PTB remains limited by the modest accuracy of prediction methods, namely transvaginal ultrasound (TVS) cervical length (CL) measurement and quantitative cervicovaginal fetal fibronectin (FFN) estimation. We report the first substantive study detailing the predictive performance of a cervical probe device based on electrical impedance spectroscopy (EIS) for PTB - the EleCtriCaL Impedance Prediction of Preterm birth by spectroscopy of the cervix (ECCLIPPx) study. We aimed to compare the accuracy of cervical EIS-based prediction of spontaneous PTB with that of prediction using TVS-CL and FFN in asymptomatic women in the mid-trimester. METHODS We studied asymptomatic women with a singleton pregnancy at 20-22 weeks' and 26-28 weeks' gestation. EIS was performed using a Sheffield Mark 5.0 device that makes measurements in the frequency range 76 Hz to 625 kHz using a small probe housing tetrapolar electrodes. TVS-CL and FFN were also measured. The associations of cervical EIS, TVS-CL and FFN with spontaneous delivery before 37 weeks and before 32 weeks were determined by multivariate linear and non-linear logistic regression analysis. Areas under the receiver-operating-characteristics curves (AUC) plots of sensitivity against specificity were used to compare the predictive performance of all parameters, both in isolation and in combination. RESULTS Of the 365 asymptomatic women studied at 20-22 weeks who were not receiving treatment, 29 had spontaneous PTB, 14 had indicated PTB and 322 had term birth. At the higher frequencies assessed, cervical EIS predicted spontaneous PTB before 37 weeks with an AUC of 0.76 (95% CI, 0.71-0.81), compared with AUCs of 0.72 (95% CI, 0.66-0.76) for TVS-CL and 0.62 (95% CI, 0.56-0.72) for FFN. Combining all three assessments improved the prediction of spontaneous PTB before 37 weeks (AUC, 0.79 (95% CI, 0.74-0.83)) compared with TVS-CL and FFN alone. Incorporating a history of spontaneous PTB (defined as previous mid-trimester miscarriage or spontaneous PTB (14 to < 37 weeks)) into the cervical EIS prediction model improved the accuracy of prediction of spontaneous PTB before 37 weeks (AUC, 0.83 (95% CI, 0.78-0.87)) and before 32 weeks (AUC, 0.86 (95% CI, 0.82-0.90)). CONCLUSIONS Mid-trimester cervical EIS assessment predicts spontaneous PTB. Larger confirmatory studies investigating its potential clinical utility and to inform effective preventive interventions are required. © 2020 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
Affiliation(s)
- D O C Anumba
- Academic Unit of Reproductive and Developmental Medicine, Department of Oncology and Metabolism, University of Sheffield, Sheffield, UK
| | - V Stern
- Academic Unit of Reproductive and Developmental Medicine, Department of Oncology and Metabolism, University of Sheffield, Sheffield, UK
| | - J T Healey
- Medical Physics and Clinical Engineering, University of Sheffield, Sheffield, UK
| | - S Dixon
- School of Health and Related Research (ScHARR), University of Sheffield, Sheffield, UK
| | - B H Brown
- Medical Physics and Clinical Engineering, University of Sheffield, Sheffield, UK
| |
Collapse
|
5
|
Yao X, Li D, Park HC, Chen D, Guan H, Mahendroo M, Li X. Ultra-sensitive optical coherence elastography using a high-dynamic-range force loading scheme for cervical rigidity assessment. BIOMEDICAL OPTICS EXPRESS 2020; 11:688-698. [PMID: 32133219 PMCID: PMC7041475 DOI: 10.1364/boe.383720] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 12/16/2019] [Accepted: 12/22/2019] [Indexed: 05/29/2023]
Abstract
An ultra-sensitive, wide-range force loading scheme is proposed for compression optical coherence elastography (OCE) that allows for the quantitative analysis of cervical tissue elasticity ex vivo. We designed a force loading apparatus featuring a water sink for minuscule incremental loading through a volume-controlled water droplet, from which the Young's modulus can be calculated by fitting the stress-strain curve. We validated the performance of the proposed OCE system on homogenous agar phantoms, showing the Young's modulus can be accurately estimated using this scheme. We then measured the Young's modulus of rodent cervical tissues acquired at different gestational ages, showing that the cervical rigidity of rodents was significantly dropped when entering the third trimester of pregnancy.
Collapse
Affiliation(s)
- Xinwen Yao
- Department of Biomedical Engineering, 720 Rutland Ave, Baltimore, MD 21205, USA
- SERI-NTU Advanced Ocular Engineering (STANCE), 50 Nanyang Drive #04-13, Singapore 637553, Singapore
- These authors contribute equally to this work
| | - Dawei Li
- Department of Biomedical Engineering, 720 Rutland Ave, Baltimore, MD 21205, USA
- These authors contribute equally to this work
| | - Hyeon-Cheol Park
- Department of Biomedical Engineering, 720 Rutland Ave, Baltimore, MD 21205, USA
| | - Defu Chen
- Department of Biomedical Engineering, 720 Rutland Ave, Baltimore, MD 21205, USA
| | - Honghua Guan
- Department of Biomedical Engineering, 720 Rutland Ave, Baltimore, MD 21205, USA
| | - Mala Mahendroo
- Department of Obstetrics and Gynecology, The University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| | - Xingde Li
- Department of Biomedical Engineering, 720 Rutland Ave, Baltimore, MD 21205, USA
| |
Collapse
|
6
|
Salaets E, Richter J. Prediction of duration of labor based on biomechanical measurements of the cervix: A preliminary study. Eur J Obstet Gynecol Reprod Biol 2019; 244:25-30. [PMID: 31731020 DOI: 10.1016/j.ejogrb.2019.10.045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2019] [Accepted: 10/23/2019] [Indexed: 11/18/2022]
Abstract
OBJECTIVE Induction of labor is a common procedure in obstetrics. Predictability of duration of labor could facilitate planning as well as patient's satisfaction. The primary purpose of this study was to evaluate the usefulness of a new biomechanical measurement of the cervix based on the aspiration technique for predicting the duration of labor after induction. STUDY DESIGN This was a prospective single centre study. Inclusion criteria were term nulliparous pregnant women with an unfavourable cervix who needed an induction of labor. Digital (Bishop score), sonographic (cervical length and cervical consistency index (CCI)) as well as aspiration measurements (closure pressure) of the cervix were performed and compared to duration of labor. The technical feasibility and the acceptability of the measurements were explored. RESULTS There were no technical complications of the sonographic or aspiration measurements. Measuring the Bishop score was reported as most painful examination. Both the time to active phase of labor and the time to delivery is significantly correlated with the Bishop score, but not with the cervical length, CCI or closure pressure. CONCLUSION The new biomechanical measurement of the cervix, based on the aspiration technique, is technically feasible and acceptable. In our small cohort no correlation was found between the closure pressure and the duration of labor.
Collapse
Affiliation(s)
- Eline Salaets
- Department of Gynecology and Obstetrics, UZ Leuven, Leuven, Belgium.
| | - Jute Richter
- Department of Gynecology and Obstetrics, UZ Leuven, Leuven, Belgium; Department of Regeneration and Development, KU Leuven, Leuven, Belgium
| |
Collapse
|
7
|
Baños N, Perez-Moreno A, Julià C, Murillo-Bravo C, Coronado D, Gratacós E, Deprest J, Palacio M. Quantitative analysis of cervical texture by ultrasound in mid-pregnancy and association with spontaneous preterm birth. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2018; 51:637-643. [PMID: 28508418 DOI: 10.1002/uog.17525] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Revised: 04/14/2017] [Accepted: 05/05/2017] [Indexed: 06/07/2023]
Abstract
OBJECTIVE New tools are required to improve the identification of women who are at increased risk for spontaneous preterm birth (sPTB). Quantitative analysis of tissue texture on ultrasound has been used to extract robust features from the ultrasound image to detect subtle changes in its microstructure. This may be applied to the cervix. The aim of this study was to determine if there is an association between quantitative analysis of cervical texture (CTx) on mid-trimester ultrasound and sPTB < 37 + 0 weeks' gestation. METHODS This was a single-center nested case-control study of a prospective cohort of 677 consecutive women with singleton pregnancy assessed between 19 + 0 and 24 + 6 weeks' gestation. Women at increased risk for sPTB were included unless they received treatment to prevent sPTB. Women who delivered < 37 + 0 weeks (sPTB) were considered as cases and were matched in a 1: 10 ratio with randomly selected contemporary controls who delivered at term. For each woman, one ultrasound image of the cervix was obtained for which quality was assessed, cervical length (CL) measured offline and a region of interest in the midportion of the anterior cervical lip delineated for use in local binary patterns analysis of CTx. A learning algorithm was developed to obtain the combination of CTx features best associated with sPTB based on feature transformation and discriminant analysis regression. The ability of the learning algorithm to predict sPTB was evaluated using a leave-one-out cross-validation technique, which produced a CTx-based score for each participant. Receiver-operating characteristics (ROC) curves were produced and sensitivity, specificity, and positive and negative likelihood ratios were calculated for the optimal cut-off based on the ROC curve. The results were compared with those obtained for CL. Investigators studying the images were blinded to pregnancy outcome at all times. RESULTS Images from 310 women (27 cases and 283 controls) were of sufficient quality and included in the study. Median CTx-based score was significantly lower in cases compared with controls (-1.01 vs -0.07, P ≤ 0.0001). CTx-based score maintained its significant association with sPTB after adjusting for possible confounders (history of sPTB, conization or Müllerian malformation, and CL < 25 mm). CTx-based score was a better predictor of sPTB (AUC, 0.77; 95% CI, 0.66-0.87) than was CL (AUC, 0.60; 95% CI, 0.47-0.72) (P = 0.03). Median CL was similar for cases and controls (37.7 vs 38.6 mm, P = 0.26), although cases were more likely to have CL < 25 mm (18.5% vs 0.4%, P < 0.001). CONCLUSION Quantitative analysis of CTx enables the extraction of information relevant to sPTB from ultrasound images to generate a CTx-based score that is associated independently with sPTB. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- N Baños
- Fetal i+D Fetal Medicine Research Center, BCNatal - Barcelona Center for Maternal-Fetal and Neonatal Medicine, Hospital Clínic and Hospital Sant Joan de Deu, Institut Clínic de Ginecologia, Obstetricia i Neonatologia, Institut d'Investigacions Biomèdiques August Pi i Sunyer, Universitat de Barcelona, and Center for Biomedical Research on Rare Diseases (CIBER-ER), Barcelona, Spain
| | | | - C Julià
- Fetal i+D Fetal Medicine Research Center, BCNatal - Barcelona Center for Maternal-Fetal and Neonatal Medicine, Hospital Clínic and Hospital Sant Joan de Deu, Institut Clínic de Ginecologia, Obstetricia i Neonatologia, Institut d'Investigacions Biomèdiques August Pi i Sunyer, Universitat de Barcelona, and Center for Biomedical Research on Rare Diseases (CIBER-ER), Barcelona, Spain
| | - C Murillo-Bravo
- Fetal i+D Fetal Medicine Research Center, BCNatal - Barcelona Center for Maternal-Fetal and Neonatal Medicine, Hospital Clínic and Hospital Sant Joan de Deu, Institut Clínic de Ginecologia, Obstetricia i Neonatologia, Institut d'Investigacions Biomèdiques August Pi i Sunyer, Universitat de Barcelona, and Center for Biomedical Research on Rare Diseases (CIBER-ER), Barcelona, Spain
| | - D Coronado
- Transmural Biotech S. L., Barcelona, Spain
| | - E Gratacós
- Fetal i+D Fetal Medicine Research Center, BCNatal - Barcelona Center for Maternal-Fetal and Neonatal Medicine, Hospital Clínic and Hospital Sant Joan de Deu, Institut Clínic de Ginecologia, Obstetricia i Neonatologia, Institut d'Investigacions Biomèdiques August Pi i Sunyer, Universitat de Barcelona, and Center for Biomedical Research on Rare Diseases (CIBER-ER), Barcelona, Spain
| | - J Deprest
- Clinical Department Obstetrics and Gynecology, University Hospitals KU Leuven and Academic Department Development and Regeneration, Biomedical Sciences, KU Leuven, Leuven, Belgium
| | - M Palacio
- Fetal i+D Fetal Medicine Research Center, BCNatal - Barcelona Center for Maternal-Fetal and Neonatal Medicine, Hospital Clínic and Hospital Sant Joan de Deu, Institut Clínic de Ginecologia, Obstetricia i Neonatologia, Institut d'Investigacions Biomèdiques August Pi i Sunyer, Universitat de Barcelona, and Center for Biomedical Research on Rare Diseases (CIBER-ER), Barcelona, Spain
| |
Collapse
|
8
|
Hee L. Overview of the methods available for biomechanical testing of the uterine cervix in vivo. Acta Obstet Gynecol Scand 2014; 93:1219-37. [PMID: 25174701 DOI: 10.1111/aogs.12483] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2014] [Accepted: 08/16/2014] [Indexed: 01/01/2023]
Abstract
OBJECTIVE To give an overview of the methods available for biomechanical testing of the non-pregnant and pregnant uterine cervix in vivo. METHODS The following databases were searched. PubMed, Embase, and Cochrane Library. Additional studies were identified from reference lists. Only studies on in vivo biomechanical testing on both pregnant and non-pregnant women were included. MAIN OUTCOME MEASURES Estimation of distensibility, compressibility, and biochemical composition of the uterine cervix. RESULTS The distensibility methods evaluated a physiologic variable and might serve as a gold standard; however, they may never be clinically useful as they involve instrumentation of the cervical canal. The compression methods evaluated an unphysiological variable but despite that, they seemed to evaluate biologically relevant figures and were non-invasive. Of the methods evaluating the biomechanical properties indirectly, those based on ultrasound may be clinically useful. Other indirect methods only measured variables within the most superficial layer of the distal uterine cervix, so further studies are needed to evaluate whether these measurements reflect the entire organ. Both compression methods and indirect methods were similar or superior to the Bishop score and to cervical length measurements regarding prediction of spontaneous preterm delivery and successful induction of labor in small studies. CONCLUSION The methods may have the potential to detect the biomechanical changes in the uterine cervix before the cervical length has shortened. The most promising methods need large-scale clinical testing regarding induction of labor and preterm delivery before they can be used in the clinic.
Collapse
Affiliation(s)
- Lene Hee
- Institute of Clinical Medicine, Aarhus University, Aarhus, Denmark
| |
Collapse
|
9
|
Mazza E, Parra-Saavedra M, Bajka M, Gratacos E, Nicolaides K, Deprest J. In vivo assessment of the biomechanical properties of the uterine cervix in pregnancy. Prenat Diagn 2014; 34:33-41. [PMID: 24155152 DOI: 10.1002/pd.4260] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2013] [Revised: 10/14/2013] [Accepted: 10/17/2013] [Indexed: 02/02/2023]
Abstract
Measuring the stiffness of the cervix might be useful in the prediction of preterm delivery or successful induction of labor. For that purpose, a variety of methods for quantitative determination of physical properties of the pregnant cervix have been developed. Herein, we review studies on the clinical application of these new techniques. They are based on the quantification of mechanical, optical, or electrical properties associated with increased hydration and loss of organization in collagen structure. Quasi-static elastography determines relative values of stiffness; hence, it can identify differences in deformability. Quasi-static elastography unfortunately cannot quantify in absolute terms the stiffness of the cervix. Also, the current clinical studies did not demonstrate the ability to predict the time point of delivery. In contrast, measurement of maximum deformability of the cervix (e.g. quantified with the cervical consistency index) provided meaningful results, showing an increase in compliance with gestational age. These findings are consistent with aspiration measurements on the pregnant ectocervix, indicating a progressive decrease of stiffness along gestation. Cervical consistency index and aspiration measurements therefore represent promising techniques for quantitative assessment of the biomechanical properties of the cervix.
Collapse
|
10
|
Etemadi M, Chung P, Heller JA, Liu JA, Rand L, Roy S. Towards BirthAlert--A Clinical Device Intended for Early Preterm Birth Detection. IEEE Trans Biomed Eng 2013; 60:3484-93. [PMID: 23893706 PMCID: PMC4605421 DOI: 10.1109/tbme.2013.2272601] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Preterm birth causes 1 million infant deaths worldwide every year, making it the leading cause of infant mortality. Existing diagnostic tests such as transvaginal ultrasound or fetal fibronectin either cannot determine if preterm birth will occur in the future or can only predict the occurrence once cervical shortening has begun, at which point it is too late to reverse the accelerated parturition process. Using iterative and rapid prototyping techniques, we have developed an intravaginal proof-of-concept device that measures both cervical bioimpedance and cervical fluorescence to characterize microstructural changes in a pregnant woman's cervix in hopes of detecting preterm birth before macroscopic changes manifest in the tissue. If successful, such an early alert during this "silent phase" of the preterm birth syndrome may open a new window of opportunity for interventions that may reverse and avoid preterm birth altogether.
Collapse
Affiliation(s)
- Mozziyar Etemadi
- Department of Bioengineering and Therapeutic Sciences, University of California, San Francisco, CA 94158 USA
| | - Philip Chung
- Department of Bioengineering and Therapeutic Sciences, University of California, San Francisco, CA 94158 USA ()
| | - J. Alex Heller
- University of California, San Francisco, CA 94158 USA, and also with the University of California, Berkeley, CA 94720 USA ()
| | - Jonathan A. Liu
- Keck School of Medicine, University of Southern California, Los Angeles, CA 90089 USA ()
| | - Larry Rand
- Department of Obstetrics and Gynecology and Reproductive Sciences, University of California, San Francisco, CA 94143 USA ()
| | - Shuvo Roy
- Department of Bioengineering and Therapeutic Sciences, University of California, San Francisco, CA 94158 USA ()
| |
Collapse
|
11
|
Etemadi M, Chung P, Heller JA, Liu J, Grossman-Kahn R, Rand L, Roy S. Novel device to trend impedance and fluorescence of the cervix for preterm birth detection. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2013; 2013:176-9. [PMID: 24109653 DOI: 10.1109/embc.2013.6609466] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Preterm birth is the leading cause of worldwide neonatal mortality. It follows a pathologically accelerated form of the normal processes that govern cervical softening and dilation. Softening and dilation occur due to changes in cervical collagen crosslinking, which can be measured non-invasively by changes in tissue fluorescence and impedance. We present a novel device designed specifically to take fluorescence and impedance measurements throughout pregnancy, with the end goal of fusing and trending these measurements to form an early diagnosis of preterm labor.
Collapse
|
12
|
Jokhi RP, Brown BH, Anumba DOC. The role of cervical Electrical Impedance Spectroscopy in the prediction of the course and outcome of induced labour. BMC Pregnancy Childbirth 2009; 9:40. [PMID: 19725953 PMCID: PMC3224746 DOI: 10.1186/1471-2393-9-40] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2009] [Accepted: 09/02/2009] [Indexed: 12/03/2022] Open
Abstract
Background Previous work by us and others had suggested that cervical electrical impedance spectroscopy (EIS) may be predictive of the outcome of induced labour. We sought to determine which probe configuration of the EIS device is predictive of the outcome of induced labour and compare this to digital assessment by the Bishop score. Methods In a prospective cohort of 205 women admitted for induction of labour, we used four probes of diameter 3, 6, 9 and 12 mm connected to an impedance meter to measure cervical resistivity (CR) in Ohm.meters at 14 electrical frequencies and compared their values to digital assessment of the cervix by the Bishop score for the prediction of the outcome of induced labour. We tested the association of labour characteristics and outcomes with CR and Bishop score by stepwise multilinear regression analyses, and the accuracy of prediction of categorical clinical outcomes by analysis of the area under the curves (AUC) of derived Receiver Operator Characteristic (ROC) curves. Results Of the four CR probe dimensions studied, only the 12 mm probe was predictive of any labour indices. In the frequency range 19 - 156 kHz, CR obtained with this probe was higher in women who delivered by caesarean section (CS) than those who delivered vaginally, and in labours lasting > 24 hrs. Cervical resistivity at 78.1 kHz best predicted vaginal delivery [optimal cut-off <2.25 Ohm.meter, AUC 0.66 (95% CI 0.59-0.72), sensitivity 71.0%, specificity 56.5%, LR+ 1.63, LR- 0.51, P < 0.01] and labour duration >24 hrs [optimal cut-off 2.27 Ω.m, AUC 0.65 (95% CI 0.58, 0.72), sensitivity 71%, specificity 59%, LR+ 1.72, LR- 0.50, P < 0.05]. In contrast digital assessment by the Bishop score neither predicted vaginal delivery nor the duration of labour. However, Bishop score predicted time to onset of labour > 12 hours and induction-delivery interval < 24 hrs [optimal cut-off ≤ 4, AUC 0.8 (95% CI 0.75, 0.86), sensitivity 77%, specificity 76%, LR+ 3.3, LR- 0.3, P < 0.05] whilst CR did not. Conclusion Cervical resistivity appears predictive of labour duration and delivery mode following induced labour. However the low predictive values obtained suggest that its current design proffers no immediate clinical utility.
Collapse
Affiliation(s)
- Roobin P Jokhi
- University of Sheffield, Sheffield Teaching Hospitals NHS Trust, Sheffield, UK.
| | | | | |
Collapse
|
13
|
|
14
|
Jokhi RP, Ghule VV, Brown BH, Anumba DOC. Reproducibility and repeatability of measuring the electrical impedance of the pregnant human cervix-the effect of probe size and applied pressure. Biomed Eng Online 2009; 8:10. [PMID: 19534806 PMCID: PMC2704213 DOI: 10.1186/1475-925x-8-10] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2009] [Accepted: 06/17/2009] [Indexed: 12/20/2022] Open
Abstract
Background The utility of cervical electrical impedance spectroscopy (EIS) as a diagnostic tool is being investigated in clinical trials. We sought to assess the reliability of two different sizes of tetrapolar probes used in measuring cervical impedance. Methods Cervical transfer impedance was measured at 14 frequencies between 76 and 625 000 Hz from 11 pregnant subjects at term. Repeated measurements were taken with two probes (3 mm and 12 mm diameter) applied softly (approximately 0.7 Newton of force), and firmly (approximately 2.2 Newton) to the surface of the cervix by two observers. The intra-class correlation coefficient (ICC), coefficient of variation (CV) and repeatability standard deviations (SD) were derived from these measurements and compared. Results Measurements taken by one observer were highly repeatable for both probes as demonstrated by high ICC and low CV values. Probe performance was improved further by firm application. Firm application of the 3 mm probe resulted in ICC values that ranged from 0.936 to 0.986 (p = 0.0001) and CV values between 1.0 and 3.4%. Firm pressure with the 12 mm probe resulted in ICC values that ranged between 0.914 and 0.988 (p = 0.0001) with CV values between 0.7 and 2.1%. In addition, the repeatability SD was low across all frequencies implying that there was low intra-observer variability. Measurements taken by 2 observers with firm application of the 12 mm probe demonstrated moderate reproducibility between 9.8 and 156 kHz, the frequency range in which previous clinical studies have shown predictive association between high cervical resistivity and vaginal delivery: ICC values ranged between 0.528 and 0.638 (p < 0.05), CV values were between 3.3 and 5.2% and reproducibility SD values were also low. In contrast the 3 mm probe demonstrated poor reproducibility at all study frequencies. Conclusion Measuring cervical resistivity by a single observer with both the 3 and 12 mm probes is highly repeatable whilst inter-observer reproducibility is poor with the 3 mm probe but moderately good when the 12 mm probe is firmly applied to the cervix in the frequency range 9.8 to 156 kHz, consistent with our observations of probe performance in clinical trials.
Collapse
Affiliation(s)
- Roobin P Jokhi
- Academic Unit of Reproductive and Developmental Medicine, University of Sheffield and Sheffield Teaching Hospitals NHS Trust, Sheffield, UK.
| | | | | | | |
Collapse
|
15
|
Gandhi SV, Walker D, Milnes P, Mukherjee S, Brown BH, Anumba DOC. Electrical impedance spectroscopy of the cervix in non-pregnant and pregnant women. Eur J Obstet Gynecol Reprod Biol 2006; 129:145-9. [PMID: 16517044 DOI: 10.1016/j.ejogrb.2005.12.029] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2005] [Revised: 11/09/2005] [Accepted: 12/12/2005] [Indexed: 11/22/2022]
Abstract
OBJECTIVES We sought to validate and measure the electrical impedance of the uterine cervix in non-pregnant and pregnant women by spectroscopy. STUDY DESIGN Cervical stromal impedance (CSI) was measured in 50 non-pregnant, 20 1st, 20 2nd and 50 3rd trimester pregnant women. The technique was also validated by comparing in vivo data to a finite element (FE) model of cervical tissue. RESULTS CSI agreed well with the FE model and was highly reproducible in all study groups. Mean (S.E.) CSI at 4-819 kHz was higher in pregnant (2.78 +/- 0.09 Omega m) compared to non-pregnant (2.38 +/- 0.07, p < 0.01) women, and in the 3rd trimester (3.08 +/- 0.13) compared to non-pregnant (p < 0.01), 1st trimester (2.42 +/- 0.12, p < 0.001) and 2nd trimester (2.20 +/- 0.05, p < 0.001) pregnant women. CONCLUSION Measurement of CSI provides a non-invasive method of assessing cervical tissue characteristics. Cervical extracellular matrix synthesis and leukocyte infiltration may account for the increased tissue impedance noted in the 3rd trimester.
Collapse
Affiliation(s)
- Saurabh V Gandhi
- Academic Unit of Reproductive and Developmental Medicine, University of Sheffield, Sheffield Teaching Hospitals NHS Trust, Sheffield, United Kingdom
| | | | | | | | | | | |
Collapse
|
16
|
Comparison of human uterine cervical electrical impedance measurements derived using two tetrapolar probes of different sizes. Biomed Eng Online 2006; 5:62. [PMID: 17125510 PMCID: PMC1684260 DOI: 10.1186/1475-925x-5-62] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2006] [Accepted: 11/24/2006] [Indexed: 11/10/2022] Open
Abstract
Background We sought to compare uterine cervical electrical impedance spectroscopy measurements employing two probes of different sizes, and to employ a finite element model to predict and compare the fraction of electrical current derived from subepithelial stromal tissue. Methods Cervical impedance was measured in 12 subjects during early pregnancy using 2 different sizes of the probes on each subject. Results Mean cervical resistivity was significantly higher (5.4 vs. 2.8 Ωm; p < 0.001) with the smaller probe in the frequency rage of 4–819 kHz. There was no difference in the short-term intra-observer variability between the two probes. The cervical impedance measurements derived in vivo followed the pattern predicted by the finite element model. Conclusion Inter-electrode distance on the probes for measuring cervical impedance influences the tissue resistivity values obtained. Determining the appropriate probe size is necessary when conducting clinical studies of resistivity of the cervix and other human tissues.
Collapse
|
17
|
Abstract
Around 20% of all deliveries are preceded by labour induction, a proportion that has not varied dramatically over recent years. Fetal death was the only indication for labour induction centuries ago, while this is now a very rare indication, with prolonged pregnancy and maternal hypertensive disorders being the major indications for the last 50–60 years. Techniques for inducing labour have also changed from dietary delicacies and verbal threats giving way to physical stimulation mainly achieved by cervical stretching and amniotomy and more recently to sophisticated pharmacological manipulation using oxytocin and prostaglandins, based on our expanding knowledge of the physiological processes involved in spontaneous parturition. Relaxin, antiprogestins, nitric oxide as well as complementary medicines have also been explored in recent years. Successful induction is, however, still not guaranteed and there has been increasing emphasis during the past decade on exploring strategies for identifying the probability of success. Measurement of fetal fibronectin in cervical mucus, maternal serum nitrite/nitrate concentrations, ultrasound delineation of cervical form and electrical impedance measurements across the cervix are all being investigated. Safety, success, and patient satisfaction continue to be the major objectives with economic evaluations now becoming a significant factor in the search for the ideal induction method.
Collapse
Affiliation(s)
- I Z Mackenzie
- Reader in Obstetrics & Gynaecology University of Oxford, John Radcliffe Hospital.
| |
Collapse
|