1
|
Brešković T, Lisica L, Jurišić Z, Petrović D, Sikirić I, Metličić V, Anić A. Ablation of accessory pathways in different anatomic locations using focal pulsed field ablation. Heart Rhythm 2024; 21:1211-1217. [PMID: 38499129 DOI: 10.1016/j.hrthm.2024.03.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Accepted: 03/05/2024] [Indexed: 03/20/2024]
Abstract
BACKGROUND Ablation of accessory pathways (APs) is the cornerstone for treatment of patients with Wolff-Parkinson-White syndrome and manifestation of atrioventricular reentrant tachycardia. Pulsed field ablation (PFA) is a new type of nonthermal energy source delivered to the underlying tissue via the ablation catheter and used for ablation of arrhythmic substrates. OBJECTIVE The purpose of this study was to determine the efficiency and long-term outcome of ablation of APs of different localizations using a focal pulsed electrical field. METHODS Electrophysiological study was performed in patients with indication for AP ablation. An ablation catheter was used to map the position of AP insertion. Pulsed electric field was delivered through a standard ablation catheter. In left-sided APs, the first ablation attempt was within the coronary sinus (CS). Patient follow-up was scheduled 1-3 months after the ablation. Additional check-up was performed after 6 and 12 months. RESULTS Fourteen 14 patients (3 pediatric) were treated. Termination of AP conduction was achieved in all procedures. The cohort consisted of 3 right free wall, 3 posteroseptal, and 8 left-sided APs. Ablation through CS was successfully used in 7 of 8 patients with left-sided APs. No complications were reported. Median follow-up was 5.5 months. Conduction recurrence through AP was documented in 1 patient. CONCLUSION Focal PFA for AP shows promising results in terms of efficacy and safety. A high rate of successful termination of left-sided APs by ablation within CS may represent a new standard approach. The safety and efficacy profile of PFA seems to be transferable to the pediatric population.
Collapse
Affiliation(s)
- Toni Brešković
- Department of Cardiology, University Hospital Center Split, Split, Croatia.
| | - Lucija Lisica
- Department of Cardiology, University Hospital Center Split, Split, Croatia
| | - Zrinka Jurišić
- Department of Cardiology, University Hospital Center Split, Split, Croatia
| | - Davor Petrović
- Division of Cardiology, Department of Pediatrics, University Hospital Center Split, Split, Croatia
| | - Ivan Sikirić
- Department of Cardiology, University Hospital Center Split, Split, Croatia
| | - Vitomir Metličić
- Division of Cardiology, Department of Pediatrics, University Hospital Center Split, Split, Croatia
| | - Ante Anić
- Department of Cardiology, University Hospital Center Split, Split, Croatia
| |
Collapse
|
2
|
Kistler PM, Sanders P, Amarena JV, Bain CR, Chia KM, Choo WK, Eslick AT, Hall T, Hopper IK, Kotschet E, Lim HS, Ling LH, Mahajan R, Marasco SF, McGuire MA, McLellan AJ, Pathak RK, Phillips KP, Prabhu S, Stiles MK, Sy RW, Thomas SP, Toy T, Watts TW, Weerasooriya R, Wilsmore BR, Wilson L, Kalman JM. 2023 Cardiac Society of Australia and New Zealand Expert Position Statement on Catheter and Surgical Ablation for Atrial Fibrillation. Heart Lung Circ 2024; 33:828-881. [PMID: 38702234 DOI: 10.1016/j.hlc.2023.12.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Accepted: 12/14/2023] [Indexed: 05/06/2024]
Abstract
Catheter ablation for atrial fibrillation (AF) has increased exponentially in many developed countries, including Australia and New Zealand. This Expert Position Statement on Catheter and Surgical Ablation for Atrial Fibrillation from the Cardiac Society of Australia and New Zealand (CSANZ) recognises healthcare factors, expertise and expenditure relevant to the Australian and New Zealand healthcare environments including considerations of potential implications for First Nations Peoples. The statement is cognisant of international advice but tailored to local conditions and populations, and is intended to be used by electrophysiologists, cardiologists and general physicians across all disciplines caring for patients with AF. They are also intended to provide guidance to healthcare facilities seeking to establish or maintain catheter ablation for AF.
Collapse
Affiliation(s)
- Peter M Kistler
- The Alfred Hospital, Melbourne, Vic, Australia; The Baker Heart and Diabetes Research Institute, Melbourne, Vic, Australia; University of Melbourne, Melbourne, Vic, Australia; Monash University, Melbourne, Vic, Australia.
| | - Prash Sanders
- University of Adelaide, Adelaide, SA, Australia; Royal Adelaide Hospital, Adelaide, SA, Australia
| | | | - Chris R Bain
- The Alfred Hospital, Melbourne, Vic, Australia; Monash University, Melbourne, Vic, Australia
| | - Karin M Chia
- Royal North Shore Hospital, Sydney, NSW, Australia
| | - Wai-Kah Choo
- Gold Coast University Hospital, Gold Coast, Qld, Australia; Royal Darwin Hospital, Darwin, NT, Australia
| | - Adam T Eslick
- University of Sydney, Sydney, NSW, Australia; The Canberra Hospital, Canberra, ACT, Australia
| | | | - Ingrid K Hopper
- The Alfred Hospital, Melbourne, Vic, Australia; Monash University, Melbourne, Vic, Australia
| | - Emily Kotschet
- Victorian Heart Hospital, Monash Health, Melbourne, Vic, Australia
| | - Han S Lim
- University of Melbourne, Melbourne, Vic, Australia; Austin Health, Melbourne, Vic, Australia; Northern Health, Melbourne, Vic, Australia
| | - Liang-Han Ling
- The Alfred Hospital, Melbourne, Vic, Australia; The Baker Heart and Diabetes Research Institute, Melbourne, Vic, Australia; University of Melbourne, Melbourne, Vic, Australia
| | - Rajiv Mahajan
- University of Adelaide, Adelaide, SA, Australia; Lyell McEwin Hospital, Adelaide, SA, Australia
| | - Silvana F Marasco
- The Alfred Hospital, Melbourne, Vic, Australia; Monash University, Melbourne, Vic, Australia
| | | | - Alex J McLellan
- University of Melbourne, Melbourne, Vic, Australia; Royal Melbourne Hospital, Melbourne, Vic, Australia; St Vincent's Hospital, Melbourne, Vic, Australia
| | - Rajeev K Pathak
- Australian National University and Canberra Heart Rhythm, Canberra, ACT, Australia
| | - Karen P Phillips
- Brisbane AF Clinic, Greenslopes Private Hospital, Brisbane, Qld, Australia
| | - Sandeep Prabhu
- The Alfred Hospital, Melbourne, Vic, Australia; The Baker Heart and Diabetes Research Institute, Melbourne, Vic, Australia; University of Melbourne, Melbourne, Vic, Australia; Monash University, Melbourne, Vic, Australia
| | - Martin K Stiles
- Waikato Clinical School, University of Auckland, Hamilton, New Zealand
| | - Raymond W Sy
- Royal Prince Alfred Hospital, Sydney, NSW, Australia; Concord Repatriation General Hospital, Sydney, NSW, Australia
| | - Stuart P Thomas
- University of Sydney, Sydney, NSW, Australia; Westmead Hospital, Sydney, NSW, Australia
| | - Tracey Toy
- The Alfred Hospital, Melbourne, Vic, Australia
| | - Troy W Watts
- Royal Melbourne Hospital, Melbourne, Vic, Australia
| | - Rukshen Weerasooriya
- Hollywood Private Hospital, Perth, WA, Australia; University of Western Australia, Perth, WA, Australia
| | | | | | - Jonathan M Kalman
- University of Melbourne, Melbourne, Vic, Australia; Royal Melbourne Hospital, Melbourne, Vic, Australia
| |
Collapse
|
3
|
Aladin AI, Arar T, Lubaina F, Bhogal S, Zhang C, Wermers JP, Ben-Dor I, Satler LF, Rogers T, Slack M, Waksman R. Gender disparities related to clinical characteristics and outcomes of patients undergoing transseptal procedures. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2024; 58:45-49. [PMID: 37393190 DOI: 10.1016/j.carrev.2023.06.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Accepted: 06/23/2023] [Indexed: 07/03/2023]
Abstract
PURPOSE Explore gender disparities in patients undergoing transseptal puncture (TSP) for selected transcatheter cardiac intervention procedures. METHODS Patients who underwent TSP from January 2015 through September 2021 were reviewed. Primary outcomes were procedural and in-hospital major adverse events. Secondary endpoints were procedural success and hospitalization length of stay (LOS) >1 day. Unadjusted and multivariable-adjusted logistic regression analyses were performed to assess gender differences for in-hospital adverse events. RESULTS The study cohort comprised 510 patients (mean [SD] age, 74 [14.0] years); 246 women (48 %) underwent TSP for left atrial appendage occlusion (LAAO) or transcatheter edge-to-edge-repair (TEER). Compared with men, women were younger, had higher CHA2DS2-VASc scores, and were more likely to have had a prior ischemic stroke, but were less likely to have paroxysmal atrial fibrillation. After multivariable adjustment, there were no differences between genders in aborted or canceled procedures (odds ratio [OR]: 0.43; 95 % confidence interval [CI]: 0.10-1.96; p = 0.277), any adverse events (OR: 1.00; 95 % CI: 0.58-1.70; p = 0.98), major adverse events (OR: 1.60; 95 % CI: 0.90-2.80; p = 0.11), or death (OR: 1.00; 95 % CI: 0.20-5.00; p = 0.31). Subgroup analysis for LAAO procedures showed that at 30 days, women had higher rates of adverse events, major adverse cardiac events, and LOS >1 day. CONCLUSIONS Men and women showed no differences in procedural success and in-hospital adverse outcomes in unadjusted analysis and after multivariable adjustment, despite women having a higher risk profile among patients undergoing TSP. However, compared with men, women undergoing LAAO experienced a higher rate of in-hospital adverse events irrespective of TSP.
Collapse
Affiliation(s)
- Amer I Aladin
- Section of Interventional Cardiology, MedStar Georgetown University/Washington Hospital Center, Washington, DC, USA
| | - Tareq Arar
- Department of Internal Medicine, MedStar Georgetown University/Washington Hospital Center, Washington, DC, USA
| | - Fnu Lubaina
- Department of Internal Medicine, MedStar Georgetown University/Washington Hospital Center, Washington, DC, USA
| | - Sukhdeep Bhogal
- Section of Interventional Cardiology, MedStar Georgetown University/Washington Hospital Center, Washington, DC, USA
| | - Cheng Zhang
- Section of Interventional Cardiology, MedStar Georgetown University/Washington Hospital Center, Washington, DC, USA
| | - Jason P Wermers
- Section of Interventional Cardiology, MedStar Georgetown University/Washington Hospital Center, Washington, DC, USA
| | - Itsik Ben-Dor
- Section of Interventional Cardiology, MedStar Georgetown University/Washington Hospital Center, Washington, DC, USA
| | - Lowell F Satler
- Section of Interventional Cardiology, MedStar Georgetown University/Washington Hospital Center, Washington, DC, USA
| | - Toby Rogers
- Section of Interventional Cardiology, MedStar Georgetown University/Washington Hospital Center, Washington, DC, USA; Cardiovascular Branch, Division of Intramural Research, National Heart, Lung and Blood Institute, National Institute of Health, Bethesda, MD, USA
| | - Michael Slack
- Division of Pediatric Cardiology, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Ron Waksman
- Section of Interventional Cardiology, MedStar Georgetown University/Washington Hospital Center, Washington, DC, USA.
| |
Collapse
|
4
|
Hu F, Xu B, Qiao Z, Cheng F, Zhou Z, Zou Z, Zang M, Ding S, Hong J, Xie Y, Zhou Y, Huang J, Pu J. Angioplasty Guidewire-Assisted vs. Conventional Transseptal Puncture for Left Atrial Appendage Occlusion: a multicentre randomized controlled trial. Europace 2023; 25:euad349. [PMID: 38011331 PMCID: PMC10751848 DOI: 10.1093/europace/euad349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Accepted: 11/02/2023] [Indexed: 11/29/2023] Open
Abstract
AIMS This study was performed to compare the usability, efficiency, and safety of a modified angioplasty guidewire-assisted transseptal puncture (TSP) technique vs. the conventional approach in facilitating access into the left atrium during left atrial appendage occlusion (LAAO) procedures for the treatment of atrial fibrillation. METHODS AND RESULTS The ADVANCE-LAAO trial (Angioplasty Guidewire-Assisted vs. Conventional Transseptal Puncture for Left Atrial Appendage Occlusion) was an investigator-initiated, prospective, multicentre, randomized controlled trial (NCT05125159). Patients with atrial fibrillation who underwent LAAO were prospectively enrolled from four centres and randomly assigned to an angioplasty guidewire-assisted TSP group (n = 131) or to a conventional Brockenbrough needle TSP group (n = 132). The primary endpoint was the one-time success rate of TSP. We also analysed the TSP procedure time, failure rate of the assigned TSP type, radiation dose, contrast dose, and procedural complications in both groups. All patients in the guidewire-assisted group underwent successful TSP, whereas five in the standard conventional group switched to the guidewire-assisted approach. The guidewire-assisted puncture improved the one-time success rate (92.4 vs. 77.3%, P = 0.001), shortened the TSP procedure time (109.2 ± 48.2 vs. 120.5 ± 57.6 s, P = 0.023), and tended to have a higher rate of good coaxial orientation of the sheath with the left atrial appendage during the LAAO procedure (66.4 vs. 54.5%, P = 0.059). No TSP-related complications occurred in the guidewire-assisted TSP group, whereas two complications occurred in the conventional TSP group. There was no significant difference in the failure rate of the assigned TSP type, the total procedure time, the total radiation dose, the rate of successful LAAO implantation, or the procedural complication rate between the two groups (all P > 0.05). CONCLUSION This study confirmed that angioplasty guidewire-assisted puncture can effectively improve the success rate of TSP during LAAO procedures. This novel technique has high potential for application in interventional therapies requiring TSP.
Collapse
Affiliation(s)
- Feng Hu
- Department of Cardiology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160# PuJian Road, Shanghai 200127, China
| | - Bin Xu
- Department of Cardiology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160# PuJian Road, Shanghai 200127, China
| | - Zhiqing Qiao
- Department of Cardiology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160# PuJian Road, Shanghai 200127, China
| | - Fuyu Cheng
- Department of Cardiology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160# PuJian Road, Shanghai 200127, China
| | - Zien Zhou
- Department of Cardiology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160# PuJian Road, Shanghai 200127, China
| | - Zhiguo Zou
- Department of Cardiology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160# PuJian Road, Shanghai 200127, China
| | - Minhua Zang
- Department of Cardiology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160# PuJian Road, Shanghai 200127, China
| | - Song Ding
- Department of Cardiology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160# PuJian Road, Shanghai 200127, China
| | - Jun Hong
- Department of Cardiology, Ningbo Hangzhou Bay Hospital, Ningbo, Zhejiang, China
| | - Yuquan Xie
- Department of Cardiology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160# PuJian Road, Shanghai 200127, China
- Department of Cardiology, Ningbo Hangzhou Bay Hospital, Ningbo, Zhejiang, China
| | - Yong Zhou
- Department of Cardiology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160# PuJian Road, Shanghai 200127, China
- Department of Cardiology, Punan Hospital, Pudong New District, Shanghai, China
| | - JianFeng Huang
- Department of Cardiology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160# PuJian Road, Shanghai 200127, China
- Department of Cardiology, Dachang Hospital, Baoshan District, Shanghai, China
| | - Jun Pu
- Department of Cardiology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160# PuJian Road, Shanghai 200127, China
| |
Collapse
|
5
|
Tan MC, Tan JL, Lee WJ, Srivathsan K, Sorajja D, El Masry H, Scott LR, Lee JZ. Adverse events in cryoballoon ablation for pulmonary vein isolation: Insight from the Food and Drug Administration Manufacturer and User Facility Device Experience. J Arrhythm 2023; 39:784-789. [PMID: 37799789 PMCID: PMC10549805 DOI: 10.1002/joa3.12898] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 06/13/2023] [Accepted: 07/03/2023] [Indexed: 10/07/2023] Open
Abstract
Background Real-world clinical data on the adverse events related to the use of cryoballoon catheter for pulmonary vein isolation remains limited. Objective To report and describe the adverse events related to the use of Artic Front cryoballoon catheters (Arctic Front, Arctic Front Advance, and Arctic Front Advance Pro) reported in the Food and Drug Administration's (FDA) Manufacturers and User Defined Experience (MAUDE) database. Methods We reviewed all the adverse events reported to the FDA MAUDE database over a 10.7-year study period from January 01, 2011 to September 31, 2021. All events were independently reviewed by two physicians. Results During the study period, a total of 320 procedural-related adverse events reported in the MAUDE database were identified. The most common adverse event was transient or persistent phrenic nerve palsy (PNP), accounting for 48% of all events. This was followed by cardiac perforation (15%), pulmonary vein stenosis (8%), transient ischemic attack or stroke (6%), vascular injury (4%), transient or persistent ST-elevation myocardial infarction (3%), hemoptysis (2%), pericarditis (2%), and esophageal ulcer or fistula (1%). There were six reported intra-procedural death events as a result of cardiac perforation. Conclusion The two most common procedural adverse events associated with cryoballoon ablation were PNP and cardiac perforation. All cases of procedural mortality were due to cardiac perforation.
Collapse
Affiliation(s)
- Min Choon Tan
- Department of Cardiovascular MedicineMayo Clinic ArizonaPhoenixArizonaUSA
- Department of Internal MedicineNew York Medical College at Saint Michael's Medical CenterNewarkNew JerseyUSA
| | - Jian Liang Tan
- Department of Cardiovascular MedicineHospital of the University of PennsylvaniaPhiladelphiaPennsylvaniaUSA
| | - Wei Jun Lee
- International Medical UniversityKuala LumpurMalaysia
| | | | - Dan Sorajja
- Department of Cardiovascular MedicineMayo Clinic ArizonaPhoenixArizonaUSA
| | - Hicham El Masry
- Department of Cardiovascular MedicineMayo Clinic ArizonaPhoenixArizonaUSA
| | - Luis R. Scott
- Department of Cardiovascular MedicineMayo Clinic ArizonaPhoenixArizonaUSA
| | - Justin Z. Lee
- Department of Cardiovascular MedicineCleveland ClinicClevelandOhioUSA
| |
Collapse
|
6
|
Song Y, Xing H, Koch PD, Li X, Zhang Y. The feasibility and safety of combining atrial septal defect/patent foramen ovale and left atrial appendage closure: A systematic review and meta-analysis. Front Cardiovasc Med 2023; 9:1080257. [PMID: 36684606 PMCID: PMC9854394 DOI: 10.3389/fcvm.2022.1080257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Accepted: 12/15/2022] [Indexed: 01/08/2023] Open
Abstract
Introduction Atrial Septal Defect/Patent Foramen Ovale (ASD/PFO) occlusion is performed to prevent paradoxical embolism and reduce the risk of recurrent ischemic stroke. Left atrial appendage (LAA) closure is used as an alternative to medical therapy of non-valvular atrial fibrillation for prevention of stroke. Multiple studies have examined performing LAA and ASD/PFO occlusion. However, the feasibility and safety of combined occlusion of the left atrial appendage and ASD/PFO are not clear, furthermore, these studies are limited by their small sample sizes and retrospective analysis. In this study, we aimed to systematically review and meta-analyze the feasibility and safety of combining left atrial appendage and ASD/PFO closure. Methods PubMed, Web of Science, CNKI, Cochrane Library, Embase, and WanFang database were searched up to April 2022 to identify peer-reviewed human studies on assessing the feasibility, safety, and efficacy of combining left atrial appendage and ASD/PFO closure. The primary outcome was calculated: procedural feasibility outcome and procedural safety outcome. Results A total of 10 articles, including 340 patients from multiple countries, were included in the analysis. The principal findings of our study are: compared with single LAA closure, (i) combining PFO/ASD occlusion and LAA closure had similar procedural success proportion (98.43%, 95% CI: 96.67-100.00%), (ii) similar safety event incidences developed (1.67%, 95% CI: 0.24-3.92%), subgroup analyzed safety event incidences in death was 0.00 (95% CI: 0.00-0.33%), cardiac tamponade was 0.87% (95% CI: 0.00-2.77%), device embolization was 0.00 (95% CI: 0.00-0.60%), major bleeding was 0.00 (95% CI: 0.00-0.33%), stroke was 0.00 (95% CI: 0.00-0.02%). Conclusion Although this systematic review and meta-analysis demonstrate the technical feasibility and safety of combining closure of PFO/ASD and LAA, further studies of sufficient sample size, long-term follow-up, and rigor endpoint criteria are yet needed to fully evaluate this combination procedure for its role in clinical outcomes.
Collapse
Affiliation(s)
- Yi Song
- Department of Ultrasound, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China,*Correspondence: Yi Song,
| | - Hang Xing
- Department of Surgery, Rhode Island Hospital, Warren Alpert Medical School of Brown University, Providence, RI, United States
| | - Peter David Koch
- Center for Systems Biology, Massachusetts General Hospital, Boston, MA, United States
| | - Xiaofei Li
- Division of Cardiology, Department of Medicine, Cardiovascular Research Center, Rhode Island Hospital, Warren Alpert Medical School of Brown University, Providence, RI, United States
| | - Yan Zhang
- Department of Ultrasound, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China
| |
Collapse
|
7
|
Ma C, Chen T, Chen Y, Ge J, Han W, Wang Q, Zhong J. Understanding the scope of intracardiac echocardiography in catheter ablation of ventricular arrhythmia. Front Cardiovasc Med 2022; 9:1037176. [PMID: 36386380 PMCID: PMC9650380 DOI: 10.3389/fcvm.2022.1037176] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Accepted: 10/14/2022] [Indexed: 01/03/2024] Open
Abstract
Over the last few decades, catheter ablation has emerged as the first-line treatment for ventricular arrhythmias. However, detailed knowledge of cardiac anatomy during the surgery remains the prerequisite for successful ablation. Intracardiac echocardiography (ICE) is a unique imaging technique, which provides real-time visualization of cardiac structures, and is superior to other imaging modalities in terms of precise display of cardiac tissue characteristics as well as the orientation of anatomical landmarks. This article aimed to introduce the various advantages and limitations of ICE in the ablation of ventricular arrhythmias.
Collapse
Affiliation(s)
- Chuanzhen Ma
- The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, The State and Shandong Province Joint Key Laboratory of Translational Cardiovascular Medicine, Department of Cardiology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Tongshuai Chen
- The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, The State and Shandong Province Joint Key Laboratory of Translational Cardiovascular Medicine, Department of Cardiology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Yanbo Chen
- Department of Cardiology, Weifang People’s Hospital, Weifang, China
| | - Junye Ge
- The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, The State and Shandong Province Joint Key Laboratory of Translational Cardiovascular Medicine, Department of Cardiology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Wenqiang Han
- The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, The State and Shandong Province Joint Key Laboratory of Translational Cardiovascular Medicine, Department of Cardiology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Qinhong Wang
- The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, The State and Shandong Province Joint Key Laboratory of Translational Cardiovascular Medicine, Department of Cardiology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Jingquan Zhong
- The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, The State and Shandong Province Joint Key Laboratory of Translational Cardiovascular Medicine, Department of Cardiology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, China
- Department of Cardiology, Qilu Hospital (Qingdao), Cheeloo College of Medicine, Shandong University, Qingdao, China
| |
Collapse
|
8
|
Blockhaus C, Waibler H, Guelker J, Klues H, Bufe A, Seyfarth M, Koektuerk B, Shin D. Transesophageal echocardiography guided transseptal puncture and nadir temperatures in cryoballoon pulmonary vein isolation. J Arrhythm 2022; 38:238-244. [PMID: 35387133 PMCID: PMC8977571 DOI: 10.1002/joa3.12679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 12/27/2021] [Accepted: 01/10/2022] [Indexed: 11/30/2022] Open
Abstract
Introduction Cryoballoon (CB) guided pulmonary vein isolation (PVI) is an established procedure in the treatment of atrial fibrillation (AF). Transseptal access is an indispensable step during PVI and may be associated with severe complications. For specific interventions, specific puncture sites of the fossa ovalis are advantageous. Here, we analyzed the potential impact of a transesophageal echocardiography (TOE) guided transseptal puncture on nadir temperatures in CB PVI. Methods and Results We retrospectively analyzed 209 patients undergoing CB PVI in our hospital. The use of TOE had been at the operator's discretion. No TOE-related complications such as perforation of the pharynx or esophagus or loss of teeth were noted. Concerning the applied freezes, we found significantly lower nadir temperatures in all PVs in the TOE group than in the non-TOE group. Procedure time and fluoroscopy time and complications were similar in both groups. Conclusion TOE-guided TSP in CB PVI is safe and feasible. Our study found significantly lower nadir temperatures of CB freezes after TOE-guided TSP which potentially underscores the value of a more infero-anterior puncture site.
Collapse
Affiliation(s)
- Christian Blockhaus
- Department of CardiologyHeart Centre NiederrheinHelios ClinicKrefeldGermany
- Witten‐Herdecke UniversityWittenGermany
| | - Hans‐Peter Waibler
- Department of CardiologyHeart Centre NiederrheinHelios ClinicKrefeldGermany
| | - Jan‐Erik Guelker
- Witten‐Herdecke UniversityWittenGermany
- Department of CardiologyPetrus HospitalWuppertalGermany
| | - Heinrich Klues
- Department of CardiologyHeart Centre NiederrheinHelios ClinicKrefeldGermany
| | - Alexander Bufe
- Department of CardiologyHeart Centre NiederrheinHelios ClinicKrefeldGermany
- Witten‐Herdecke UniversityWittenGermany
| | - Melchior Seyfarth
- Witten‐Herdecke UniversityWittenGermany
- Department of CardiologyHelios University HospitalWuppertalGermany
| | - Buelent Koektuerk
- Department of CardiologyHeart Centre NiederrheinHelios ClinicKrefeldGermany
- Witten‐Herdecke UniversityWittenGermany
| | - Dong‐In Shin
- Department of CardiologyHeart Centre NiederrheinHelios ClinicKrefeldGermany
- Witten‐Herdecke UniversityWittenGermany
| |
Collapse
|
9
|
Liu L, Wang Y, Liu Z, Liu Y, Liu J, Yin X, Liu X, Yang X. Use of a coronary guidewire to facilitate transseptal puncture: a randomized comparison with a conventional technique. Pacing Clin Electrophysiol 2022; 45:826-831. [PMID: 35357704 DOI: 10.1111/pace.14480] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 02/18/2022] [Accepted: 03/06/2022] [Indexed: 11/26/2022]
Abstract
INTRODUCTION Transseptal puncture (TSP) is routinely performed for left heart intervention, but it can sometimes be complex and life-threatening. This study introduced a safe and effective method to facilitate TSP for left atrial access. METHODS AND RESULTS A total of 200 patients (190 with atrial fibrillation, 10 with a left accessory pathway) were prospectively analyzed. In the guidewire group, TSP was performed using a SWARTZ sheath and a Brockenbrough needle with a 0.014-inch coronary guidewire instead of an inner stylet. The needle tip position was confirmed by pushing the guidewire into the left superior pulmonary vein after initial puncture in 100 patients. In the contrast group, TSP was performed in 100 patients using standard devices by injecting contrast to confirm needle-tip position. Left atrial access was achieved successfully in all patients in the two groups without serious complications. The guidewire group showed a higher first-pass rate for left atrial access compared with the contrast group (81.1% vs. 75% p<0.001, respectively). CONCLUSION Coronary guidewire TSP is safe and is associated with a high success rate, and it is thus a useful alternative to conventional TSP. This method is useful for patients with septal aneurysms and contrast allergies. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Lifeng Liu
- Heart Center, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
| | - Yuxing Wang
- Heart Center, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
| | - Zheng Liu
- Heart Center, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
| | - Ye Liu
- Heart Center, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
| | - Jiapeng Liu
- Heart Center, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
| | - Xiandong Yin
- Heart Center, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
| | - Xiaoqing Liu
- Heart Center, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
| | - Xinchun Yang
- Heart Center, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
10
|
Almendarez M, Alvarez-Velasco R, Pascual I, Alperi A, Moris C, Avanzas P. Transseptal puncture: Review of anatomy, techniques, complications and challenges, a critical view. Int J Cardiol 2022; 351:32-38. [PMID: 35007652 DOI: 10.1016/j.ijcard.2022.01.011] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/01/2022] [Accepted: 01/05/2022] [Indexed: 11/05/2022]
Abstract
Transseptal puncture (TSP) was initially described to gain access to the left heart for hemodynamic assessment. Continuous evolution from its origins allows interventionists to perform a myriad of procedures that otherwise would be impossible to accomplish. In the recent years, the number of procedures in cardiology that require TSP has grown exponentially. Namely, transcatheter mitral valve repair and replacement, pulmonary vein isolation and left atrium appendage occlusion. In skilled hands, it is a safe and straightforward procedure; however, a lack of knowledge of the materials, anatomy of the interatrial septum and the technique can be met with life-threatening complications. Therefore, it is imperative that interventional cardiologists master this technique to successfully overcome these obstacles and ensure clinical outcomes in patients requiring TSP. The purpose of the following review is to critically analyze the available evidence regarding TSP, provide a step-by-step approach to the technique, the available materials and tips and tricks to overcome difficulties and manage complications.
Collapse
Affiliation(s)
- Marcel Almendarez
- Heart Area. Hospital Universitario Central de Asturias, Avenida de Roma S/N, 33011 Oviedo, Spain; Research Institute of the Principado de Asturias, Avenida de Roma S/N, 33011 Oviedo, Spain
| | - Rut Alvarez-Velasco
- Heart Area. Hospital Universitario Central de Asturias, Avenida de Roma S/N, 33011 Oviedo, Spain; Research Institute of the Principado de Asturias, Avenida de Roma S/N, 33011 Oviedo, Spain
| | - Isaac Pascual
- Heart Area. Hospital Universitario Central de Asturias, Avenida de Roma S/N, 33011 Oviedo, Spain; Research Institute of the Principado de Asturias, Avenida de Roma S/N, 33011 Oviedo, Spain; Department of Medicine, Faculty of Medicine, University of Oviedo, 33006 Oviedo, Spain
| | - Alberto Alperi
- Heart Area. Hospital Universitario Central de Asturias, Avenida de Roma S/N, 33011 Oviedo, Spain; Research Institute of the Principado de Asturias, Avenida de Roma S/N, 33011 Oviedo, Spain
| | - Cesar Moris
- Heart Area. Hospital Universitario Central de Asturias, Avenida de Roma S/N, 33011 Oviedo, Spain; Research Institute of the Principado de Asturias, Avenida de Roma S/N, 33011 Oviedo, Spain; Department of Medicine, Faculty of Medicine, University of Oviedo, 33006 Oviedo, Spain
| | - Pablo Avanzas
- Heart Area. Hospital Universitario Central de Asturias, Avenida de Roma S/N, 33011 Oviedo, Spain; Research Institute of the Principado de Asturias, Avenida de Roma S/N, 33011 Oviedo, Spain; Department of Medicine, Faculty of Medicine, University of Oviedo, 33006 Oviedo, Spain.
| |
Collapse
|
11
|
Ravigopal SR, Nayar NU, Desai JP. Towards Real-time pose estimation of the Mitral Valve Robot under C-arm X-ray Fluoroscopy. IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS 2021; 3:928-935. [PMID: 35756715 PMCID: PMC9232099 DOI: 10.1109/tmrb.2021.3122351] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Mitral regurgitation (MR) is a condition caused by a deformity in the mitral valve leading to the backflow of blood into the left atrium. MR can be treated through a minimally invasive procedure and our lab is currently developing a robot that could potentially be used to treat MR. The robot would carry a clip that latches onto the valve's leaflets and closes them to minimize leakage. The robot's accurate localization is needed to navigate the clip to the leaflets successfully. This paper discusses algorithms used to track the clip's position and orientation under real-time using C-arm fluoroscopy. The positions are found through a deep learning semantic segmentation framework and the pose is found by calculating its bending and rotational angles. The robot's bending angle and the clip's rotational angle is found through an equivalent ellipse algorithm and an SVM classifier, respectively, and were validated by comparing orientations obtained from an electromagnetic tracker. The bending angle calculation has an average error of 7.7° and the rotational angle calculation is 76% for classifying them into five classes. Execution times are within 100ms and hence this could be a promising approach in real-time pose estimation.
Collapse
Affiliation(s)
- Sharan R Ravigopal
- Medical Robotics and Automation (RoboMed) Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332 USA
| | - Namrata U Nayar
- Medical Robotics and Automation (RoboMed) Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332 USA
| | - Jaydev P Desai
- Medical Robotics and Automation (RoboMed) Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332 USA
| |
Collapse
|
12
|
Seferović PM. Reply to "Endomyocardial biopsy in the hands of the electrophysiologist: the 'one-stop shop' for arrhythmic non-ischaemic cardiomyopathy". Eur J Heart Fail 2021; 23:1984. [PMID: 34529318 DOI: 10.1002/ejhf.2349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Accepted: 09/13/2021] [Indexed: 11/08/2022] Open
Affiliation(s)
- Petar M Seferović
- Serbian Academy of Sciences and Arts, Belgrade, Serbia.,Faculty of Medicine, Belgrade University, Belgrade, Serbia
| |
Collapse
|
13
|
Vale PD, Silva LTM, de Oliveira EMM, de Miranda RFC, da Silva RD, Araújo LMC, da Silva SMP, Cunha WC, Neto JS, Péres AK, Seixas TN, da Rocha JM, Margalho CS, Maia HCDA. Incidence and characteristics of transient St-segment elevation during transseptal puncture. J Interv Card Electrophysiol 2021; 63:425-430. [PMID: 34236564 DOI: 10.1007/s10840-021-01022-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Accepted: 06/22/2021] [Indexed: 11/25/2022]
Abstract
PURPOSE Delineate retrospectively and prospectively the incidence and characteristics of transient ST-segment elevation during transseptal puncture. METHODS The study retrospectively evaluated 307 patients from January 1, 2015, to December 31, 2017, and prospectively evaluated 231 patients from January 1, 2018, to July 31, 2019. RESULTS The presence of ST-segment elevation was significantly higher in the prospective sample than in the retrospective sample (5.2% vs. 1.3%, p < 0.05). Between the two groups, there was no significant difference in age, sex, comorbidities, left atrial volume index, and the etiology of atrial fibrillation among patients with ST-segment alteration. In all patients, the ST-segment elevation was observed in the inferior wall derivations, except for one patient with ST elevation in lead I, AVL, V1-V4 during the septal puncture, associated with sinus bradycardia and reversed hypotension with intravenous fluids. Comparative analysis of the systolic and diastolic arterial pressure and the minimum heart rate during the phenomenon demonstrated more severity in the retrospectively evaluated population than in the prospective population. There was a significant association between the occurrence of ST-segment elevation > 2 mm and the presence of symptoms. In these patients, coronary angiography showed no alterations. Atropine was administered to one patient who presented with junctional bradycardia after the puncture. This medication reversed the situation. CONCLUSION ST-segment elevation is a short-term phenomenon that can occur during transseptal catheterization without clinically evident symptoms. The catheter ablation procedure can be safely concluded despite the occurrence of the phenomenon.
Collapse
Affiliation(s)
- Paula D Vale
- Instituto Hospital de Base do Distrito Federal, Brasília, Brazil
| | - Livia T M Silva
- Ritmocardio Serviço de Arritmia e Eletrofisiologia de Brasília, SHLS 716 Ed Centro Clínico Sul Torre I sala 15, Brasília, DF, Brazil
| | - Edna Maria M de Oliveira
- Instituto Hospital de Base do Distrito Federal, Brasília, Brazil
- Ritmocardio Serviço de Arritmia e Eletrofisiologia de Brasília, SHLS 716 Ed Centro Clínico Sul Torre I sala 15, Brasília, DF, Brazil
| | - Ricardo F C de Miranda
- Ritmocardio Serviço de Arritmia e Eletrofisiologia de Brasília, SHLS 716 Ed Centro Clínico Sul Torre I sala 15, Brasília, DF, Brazil
| | - Renato David da Silva
- Ritmocardio Serviço de Arritmia e Eletrofisiologia de Brasília, SHLS 716 Ed Centro Clínico Sul Torre I sala 15, Brasília, DF, Brazil
| | - Lielia M C Araújo
- Ritmocardio Serviço de Arritmia e Eletrofisiologia de Brasília, SHLS 716 Ed Centro Clínico Sul Torre I sala 15, Brasília, DF, Brazil
| | | | - Wanessa C Cunha
- Instituto Hospital de Base do Distrito Federal, Brasília, Brazil
| | - José S Neto
- Ritmocardio Serviço de Arritmia e Eletrofisiologia de Brasília, SHLS 716 Ed Centro Clínico Sul Torre I sala 15, Brasília, DF, Brazil
| | - Ayrton K Péres
- Ritmocardio Serviço de Arritmia e Eletrofisiologia de Brasília, SHLS 716 Ed Centro Clínico Sul Torre I sala 15, Brasília, DF, Brazil
| | - Tamer N Seixas
- Ritmocardio Serviço de Arritmia e Eletrofisiologia de Brasília, SHLS 716 Ed Centro Clínico Sul Torre I sala 15, Brasília, DF, Brazil
| | - Jairo M da Rocha
- Instituto Hospital de Base do Distrito Federal, Brasília, Brazil
- Ritmocardio Serviço de Arritmia e Eletrofisiologia de Brasília, SHLS 716 Ed Centro Clínico Sul Torre I sala 15, Brasília, DF, Brazil
| | - Carla S Margalho
- Instituto Hospital de Base do Distrito Federal, Brasília, Brazil
- Ritmocardio Serviço de Arritmia e Eletrofisiologia de Brasília, SHLS 716 Ed Centro Clínico Sul Torre I sala 15, Brasília, DF, Brazil
| | - Henrique Cesar de A Maia
- Instituto Hospital de Base do Distrito Federal, Brasília, Brazil.
- Ritmocardio Serviço de Arritmia e Eletrofisiologia de Brasília, SHLS 716 Ed Centro Clínico Sul Torre I sala 15, Brasília, DF, Brazil.
| |
Collapse
|
14
|
Ishibashi R, Kataoka A, Watanabe Y, Kozuma K. Pseudopericardial effusion due to excess tension caused by a guide catheter during the MitraClip procedure: Pseudo-PE during MitraClip procedure. ASIAINTERVENTION 2021; 7:60-61. [PMID: 34913004 PMCID: PMC8657045 DOI: 10.4244/aij-d-21-00006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2021] [Accepted: 06/01/2021] [Indexed: 06/14/2023]
Affiliation(s)
- Ruri Ishibashi
- Department of Medicine, Division of Cardiology, Teikyo University School of Medicine, Tokyo, Japan
| | | | - Yusuke Watanabe
- Department of Medicine, Division of Cardiology, Teikyo University School of Medicine, Tokyo, Japan
| | - Ken Kozuma
- Department of Medicine, Division of Cardiology, Teikyo University School of Medicine, Tokyo, Japan
| |
Collapse
|
15
|
Yu R, Liu N, Lu J, Zhao X, Hu Y, Zhang J, Xu F, Tang R, Bai R, Akar JG, Dong J, Ma C. 3-Dimensional Transseptal Puncture Based on Electrographic Characteristics of Fossa Ovalis: A Fluoroscopy-Free and Echocardiography-Free Method. JACC Cardiovasc Interv 2020; 13:1223-1232. [PMID: 32438994 DOI: 10.1016/j.jcin.2020.03.015] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 02/18/2020] [Accepted: 03/10/2020] [Indexed: 10/24/2022]
Abstract
OBJECTIVES This study sought to define electrographic characteristics of the fossa ovalis (FO) and use these findings in developing a 3-dimensional (3D) transseptal puncture (TSP) technique that does not rely on fluoroscopy or echocardiography. BACKGROUND Traditional TSP method based on fluoroscopy or echocardiography is basically a 2-dimensional (2D) technique. A valid 3D method of TSP has not been sufficiently clarified. METHODS The shape of the FO and its center were "electrographically" defined by comparing their potential characteristics to those of the surrounding limbus. After validation by intracardiac echocardiography, this FO mapping was incorporated into 3D electroanatomical reconstruction of the right atrium. Using a new catheter connection, the transseptal needle could be visualized nonfluoroscopically and directed to the precise localization of the FO on the electroanatomic map. RESULTS A total of 276 patients who underwent atrial fibrillation ablation were included. The central FO was identified in all cases with atrial electrogram voltage at 0.33 ± 0.21 mV. The amplitude of atrial potential at the FO annulus was 1.70 ± 0.72 mV (p < 0.001). By incorporating the electrographically defined FO into the 3D electroanatomic mapping and using the transseptal needle visualization approach, TSP was successful in all patients, with 91% of the cases at the first attempt. Atrial fibrillation ablation was completed in all patients with no major complication. CONCLUSIONS Electrographic characteristics of the FO center are distinct from those of the surrounding regions. This information can be leveraged to define the FO on 3D electroanatomic mappings, thereby facilitating safe TSP without the need of ancillary imaging with fluoroscopy or echocardiography.
Collapse
Affiliation(s)
- Ronghui Yu
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China; National Clinical Research Center for Cardiovascular Diseases, Beijing, China.
| | - Nian Liu
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China; National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - Jun Lu
- Department of Cardiology, Affiliated Hospital of Qingdao University, Qingdao, China
| | - Xin Zhao
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China; National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - Yucai Hu
- Department of Cardiology, First Affiliated Hospital of Henan University of Traditional Chinese Medicine, Zhengzhou, China
| | - Jianqiang Zhang
- Department of Cardiology, Shanghai East Hospital, Tongji University, Shanghai, China
| | - Fengqiang Xu
- Department of Cardiology, Affiliated Hospital of Qingdao University, Qingdao, China
| | - Ribo Tang
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China; National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - Rong Bai
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China; National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - Joseph G Akar
- Section of Cardiology, Yale New Haven Hospital, Yale School of Medicine, New Haven, Connecticut
| | - Jianzeng Dong
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China; National Clinical Research Center for Cardiovascular Diseases, Beijing, China; Cardiovascular Center, First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Changsheng Ma
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China; National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| |
Collapse
|
16
|
Chen CB, Sandhu HS, Keane MG, Dass C, Whitman IR. Dramatic Aneurysmal Atrial Septum Identified with Intracardiac Echo Complicating Transseptal Puncture. CASE 2020; 4:115-118. [PMID: 32577588 PMCID: PMC7303242 DOI: 10.1016/j.case.2019.11.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Atrial septal aneurysm is a largely underdiagnosed phenomenon. Septal anatomy is best delineated using intracardiac echocardiography. Septal anatomy is clinically relevant with procedures involving transseptal puncture. Atrial septal aneurysms may be associated with supraventricular tachycardias.
Collapse
|
17
|
Stöckigt F, Eberhardt F, Horlitz M. Complication prevention in ablation procedures: How to perform transseptal puncture safely in case of atrial septum aneurysm. HeartRhythm Case Rep 2019; 5:529-533. [PMID: 31890566 PMCID: PMC6926205 DOI: 10.1016/j.hrcr.2019.06.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Affiliation(s)
- Florian Stöckigt
- Department of Cardiology, Electrophysiology and Rhythmology, Krankenhaus Porz am Rhein, Cologne, Germany.,Department of Cardiology, University Hospital Bonn, Bonn, Germany
| | - Frank Eberhardt
- Department of Cardiology, Evangelisches Krankenhaus Kalk, Cologne, Germany
| | - Marc Horlitz
- Department of Cardiology, Electrophysiology and Rhythmology, Krankenhaus Porz am Rhein, Cologne, Germany
| |
Collapse
|
18
|
Prospective evaluation of iatrogenic atrial septal defect after cryoballoon or radiofrequency catheter ablation of atrial fibrillation-"EVITA" study. J Interv Card Electrophysiol 2019; 56:19-27. [PMID: 31399921 DOI: 10.1007/s10840-019-00598-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2019] [Accepted: 07/16/2019] [Indexed: 10/26/2022]
Abstract
PURPOSE Iatrogenic atrial septal defect (IASD) after catheter ablation (CA) for atrial fibrillation (AF) due to transseptal puncture (TSP) can occur. The aim of this prospective study was to describe the incidence of IASD and to detect any cerebrovascular accident (CVA) after radiofrequency (RF) and cryoballoon (CB) CA. METHODS Between July 2014 and September 2016, 94 patients (pts) (RF; 48, CB; 46, 30 (31.9%) women, mean age = 60 ± 9.7 years) with paroxysmal AF were enrolled who underwent CA procedure for the first time. During RF ablation a single (n = 30, 62.5%) or double (n = 18, 37.5%) TSP was performed. Transoesophageal echocardiography before the procedure and at the 3-month and 12-month follow-up (FU) was accomplished. During the FU period, we evaluated the occurrence of any postprocedural CVA. RESULTS At the 3-month FU, IASD was detected in 17/94 (18.1%) pts; in 9/48 (18.8%) pts in the RF while in 8/46 (17.4%) pts in the CB group (p = 0.866), all of them with left-to-right shunt. In the RF group, 6/30 (20%) pts with a single TSP while 3/18 (16.7%) pts in the double TSP group had IASD (p = 0.780). 14/17 (82.4%) IASDs showed high spontaneous closure rate at the 12-month FU. None of the pts died or suffered from CVA. CONCLUSION Persistent IASD can occur rather frequently following AF CA. No significant difference was observed between the RF and CB techniques concerning the presence of IASD at 3-month. IASDs showed a high spontaneous closure rate. No cerebral thromboembolic event was observed in the 12-month FU period.
Collapse
|