1
|
Revilla JA, Priadythama I, Loh PY, Muraki S. Effects of various handle shapes and surface profiles on the hand-arm responses and comfort during short-term exposure to handle vibration. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2022; 19:353-369. [PMID: 35404763 DOI: 10.1080/15459624.2022.2063877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The magnitude of hand- (HTV) and wrist- (WTV) transmitted vibration can negatively impact upper limb responses even during short-term exposure. This study aimed to establish the effects of various handle-grip designs on the harmful impacts of vibration, sustained grip exertion, and unnatural posture. The primary focus was to investigate how using a handle grip and how three shapes with two surface profiles affect HTV, WTV, and forearm muscle activities during exposure. The secondary goal was to evaluate the immediate effects on fundamental hand functions, perceived discomfort/comfort, and perceived vibration level after exposure. The final objective was to assess which of the handle designs had the least harmful effects. Fourteen young male adults were recruited and asked to consistently grip a vibrating handle structure for 2 min while the primary parameters were recorded. Pre- and post-task measurements of secondary parameters were recorded on the six design conditions and one control condition (no handle grip). The study found that implementing a regular circular-smooth handle resulted in lower transmitted vibrations, leading to lower upper-limb discomfort, higher grip comfort, and lower perceived vibration. Additionally, shape significantly affected HTV, resulting in grip strength reduction, while surface profile did not influence transmitted vibrations but significantly impacted ring and small finger sensitivity, finger and hand discomfort, and grip comfort. Finally, forearm muscle activities were unaffected, and no significant interaction effects were observed. Circular handles also had the least negative impacts, and elliptic handles had the most negative impacts on the upper extremity because of the level of hand-handle contact stress and hand-grip effort. Meanwhile, the uneven distribution of vibration on the fingers and palm imposed by the rounded spikes on the patterned surface led to decreased finger sensitivity, higher discomfort, and lower grip comfort. Therefore, when machine operation involves moderate grip exertion, pronated forearm posture, and short-term handle vibration exposure, implementing a hard-solid handle with less hand-handle contact area, less grip effort, and even texture is recommended.
Collapse
Affiliation(s)
- Josefa Angelie Revilla
- Department of Industrial Engineering, University of the Philippines Los Baños, Laguna, Philippines
- Graduate School of Design, Kyushu University, Fukuoka, Japan
| | | | - Ping Yeap Loh
- Faculty of Design, Kyushu University, Fukuoka, Japan
| | | |
Collapse
|
2
|
Degan GA, Antonucci A, Coltrinari G, Lippiello D. Problems related to measuring the transmissibility of anti-vibration gloves. Possible efficacy for impact tools used in mining and quarrying activities. INTERNATIONAL JOURNAL OF OCCUPATIONAL SAFETY AND ERGONOMICS 2022; 29:704-716. [PMID: 35475952 DOI: 10.1080/10803548.2022.2070334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
AbstractThis commentary takes into account some of the most relevant studies investigating the transmissibility of anti-vibration (AV) gloves. AV gloves are almost useless at the palm level in the low frequencies (less than 31.5 Hz), while they generally start to have an appreciable reduction of the vibration over 400 Hz. In their use with impact tools, having a low dominant vibration frequency usually between 25-60 Hz for chipping hammers and drills, and less than 30 Hz for pneumatic breakers, the average transmissibility reduction at the palm level is 13% (min 2% - max 26%) when used with hammers, and 1% (increment of 4% and reduction of 6%) when used with breakers. The transmissibility at the finger level, especially in the low frequencies, is almost nothing or produces an increase of the vibration. Other problems related to the increase of the applied force and the reduction of dexterity are reported.
Collapse
Affiliation(s)
| | | | | | - Dario Lippiello
- Department of Engineering, University of Roma Tre, Rome, Italy
| |
Collapse
|
3
|
Dong RG, Wu JZ, Xu XS, Welcome DE, Krajnak K. A Review of Hand-Arm Vibration Studies Conducted by US NIOSH since 2000. VIBRATION 2021; 4:482-528. [PMID: 34414357 PMCID: PMC8371562 DOI: 10.3390/vibration4020030] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Studies on hand-transmitted vibration exposure, biodynamic responses, and biological effects were conducted by researchers at the Health Effects Laboratory Division (HELD) of the National Institute for Occupational Safety and Health (NIOSH) during the last 20 years. These studies are systematically reviewed in this report, along with the identification of areas where additional research is needed. The majority of the studies cover the following aspects: (i) the methods and techniques for measuring hand-transmitted vibration exposure; (ii) vibration biodynamics of the hand-arm system and the quantification of vibration exposure; (iii) biological effects of hand-transmitted vibration exposure; (iv) measurements of vibration-induced health effects; (iv) quantification of influencing biomechanical effects; and (v) intervention methods and technologies for controlling hand-transmitted vibration exposure. The major findings of the studies are summarized and discussed.
Collapse
Affiliation(s)
- Ren G. Dong
- Physical Effects Research Branch, Health Effects Laboratory Division (HELD), National Institute for Occupational Safety and Health (NIOSH), Morgantown, WV 26505, USA
| | - John Z. Wu
- Physical Effects Research Branch, Health Effects Laboratory Division (HELD), National Institute for Occupational Safety and Health (NIOSH), Morgantown, WV 26505, USA
| | - Xueyan S. Xu
- Physical Effects Research Branch, Health Effects Laboratory Division (HELD), National Institute for Occupational Safety and Health (NIOSH), Morgantown, WV 26505, USA
| | - Daniel E. Welcome
- Physical Effects Research Branch, Health Effects Laboratory Division (HELD), National Institute for Occupational Safety and Health (NIOSH), Morgantown, WV 26505, USA
| | - Kristine Krajnak
- Physical Effects Research Branch, Health Effects Laboratory Division (HELD), National Institute for Occupational Safety and Health (NIOSH), Morgantown, WV 26505, USA
| |
Collapse
|
4
|
Can Blood Flow be Used to Monitor Changes in Peripheral Vascular Function That Occur in Response to Segmental Vibration Exposure? J Occup Environ Med 2020; 61:162-167. [PMID: 30507789 DOI: 10.1097/jom.0000000000001509] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Laser Doppler blood flow measurements have been used for diagnosis or detection of peripheral vascular dysfunction. This study used a rat tail model of vibration-induced vascular injury to determine how laser Doppler measurements were affected by acute and repeated exposures to vibration, and to identify changes in the Doppler signal that were associated with the exposure. METHODS Blood flow was measured immediately after a single exposure to vibration, or before vibration exposure on days 1, 5, 10, 15, and 20 of a 20 days exposure. RESULTS After a single exposure to vibration, average tail blood flow was reduced. With 20 days of exposure, there was a reduction in the amplitude of the arterial pulse on days 10 to 20 in vibrated rats and days 15 to 20 in control rats. CONCLUSIONS More detailed statistical analyses of laser Doppler data may be needed to identify early changes in peripheral circulation after exposure to vibration.
Collapse
|
5
|
Pacurari M, Waugh S, Krajnak K. Acute Vibration Induces Peripheral Nerve Sensitization in a Rat Tail Model: Possible Role of Oxidative Stress and Inflammation. Neuroscience 2018; 398:263-272. [PMID: 30553794 DOI: 10.1016/j.neuroscience.2018.12.010] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Revised: 12/05/2018] [Accepted: 12/06/2018] [Indexed: 12/20/2022]
Abstract
Prolonged occupational exposure to hand-held vibrating tools leads to pain and reductions in tactile sensitivity, grip strength and manual dexterity. The goal of the current study was to use a rat-tail vibration model to determine how vibration frequency influences factors related to nerve injury and dysfunction. Rats were exposed to restraint, or restraint plus tail vibration at 62.5 Hz or 250 Hz. Nerve function was assessed using the current perception threshold (CPT) test. Exposure to vibration at 62.5 and 250 Hz, resulted in a reduction in the CPT at 2000 and 250-Hz electrical stimulation (i.e. increased Aβ and Aδ, nerve fiber sensitivity). Vibration exposure at 250 Hz also resulted in an increased sensitivity of C-fibers to electrical stimulation and thermal nociception. These changes in nerve fiber sensitivity were associated with increased expression of interleukin (IL)-1β and tumor necrosis factor (TNF)-α in ventral tail nerves, and increases in circulating concentrations of IL-1 β in rats exposed to 250-Hz vibration. There was an increase in glutathione, but no changes in other measures of oxidative activity in the peripheral nerve. However, measures of oxidative stress were increased in the dorsal root ganglia (DRG). These changes in pro-inflammatory factors and markers of oxidative stress in the peripheral nerve and DRG were associated with inflammation, and reductions in myelin basic protein and post-synaptic density protein (PSD)-95 gene expression, suggesting that vibration-induced changes in sensory function may be the result of changes at the exposed nerve, the DRG and/or the spinal cord.
Collapse
Affiliation(s)
- M Pacurari
- Department of Biology, Jackson State University, Jackson, MS 39217, United States
| | - S Waugh
- Engineering and Controls Technology Branch, National Institute for Occupational Safety and Health, Morgantown, WV 26501, United States
| | - K Krajnak
- Engineering and Controls Technology Branch, National Institute for Occupational Safety and Health, Morgantown, WV 26501, United States.
| |
Collapse
|
6
|
Krajnak K, Waugh S. Systemic Effects of Segmental Vibration in an Animal Model of Hand-Arm Vibration Syndrome. J Occup Environ Med 2018; 60:886-895. [PMID: 30020212 PMCID: PMC6173648 DOI: 10.1097/jom.0000000000001396] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
OBJECTIVE Epidemiology suggests that occupational exposure to hand-transmitted (segmental) vibration has local and systemic effects. This study used an animal model of segmental vibration to characterize the systemic effects of vibration. METHODS Male Sprague Dawley rats were exposed to tail vibration for 10 days. Genes indicative of inflammation, oxidative stress, and cell cycle, along were measured in the heart, kidney, prostate, and liver. RESULTS Vibration increased oxidative stress and pro-inflammatory gene expression, and decreased anti-oxidant enzymes in heart tissue. In the prostate and liver, vibration resulted in changes in the expression of pro-inflammatory factors and genes involved in cell cycle regulation. CONCLUSIONS These changes are consistent with epidemiological studies suggesting that segmental vibration has systemic effects. These effects may be mediated by changes in autonomic nervous system function, and/or inflammation and oxidative stress.
Collapse
Affiliation(s)
- Kristine Krajnak
- Engineering Controls and Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, Washington
| | | |
Collapse
|
7
|
Budd D, Holness DL. Raising awareness of hand-arm vibration syndrome (HAVS) using posters. Work 2018; 61:3-10. [PMID: 30223408 DOI: 10.3233/wor-182775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND Hand-arm vibration syndrome (HAVS) is caused by prolonged occupational exposure to hand-transmitted vibration. Although HAVS is preventable, disease awareness and prevention knowledge are lacking in high-risk workplaces; this may contribute to under-diagnosis, delays in seeking care, and poor health outcomes. Posters may be used to increase awareness in the workplace. OBJECTIVE To conduct a pilot survey in workers with HAVS about poster use in their workplaces, their recommendations for poster campaigns and training programs, and their evaluation of HAVS awareness and prevention posters. METHODS All eligible HAVS patients in the Occupational Health Clinic at St. Michael's Hospital, in Toronto, Canada, were asked to complete a questionnaire on workplace poster use and to evaluate a set of HAVS posters. RESULTS Fifty workers participated; almost all were males, aged 50 and older, working in construction. Most indicated having non-HAVS specific awareness posters in their workplaces. There was a positive evaluation of the design, content, and potential usefulness of the posters. The poster depicting finger blanching stood out most. The poster depicting anti-vibration gloves rated highest for relatability and effectiveness at conveying disease importance. CONCLUSIONS Participants supported the proposed use of industry-specific HAVS awareness posters in their workplaces. Future research should evaluate the effectiveness of these posters in the workplace.
Collapse
Affiliation(s)
- Diandra Budd
- Division of Occupational Medicine, St. Michael's Hospital, Toronto, Ontario, Canada
| | - D Linn Holness
- Dalla Lana School of Public Health and Department of Medicine, University of Toronto,Toronto, Ontario, Canada.,Division of Occupational Medicine and Centre for Urban Health Solutions, Li Ka Shing Knowledge Institute, St. Michael's Hospital, Toronto, Ontario, Canada
| |
Collapse
|
8
|
Krajnak K. Health effects associated with occupational exposure to hand-arm or whole body vibration. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH. PART B, CRITICAL REVIEWS 2018; 21:320-334. [PMID: 30583715 PMCID: PMC6415671 DOI: 10.1080/10937404.2018.1557576] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Workers in a number of different occupational sectors are exposed to workplace vibration on a daily basis. This exposure may arise through the use of powered-hand tools or hand-transmitted vibration (HTV). Workers might also be exposed to whole body vibration (WBV) by driving delivery vehicles, earth moving equipment, or through use of tools that generate vibration at low dominant frequencies and high amplitudes, such as jackhammers. Occupational exposure to vibration has been associated with an increased risk of musculoskeletal pain in the back, neck, hands, shoulders, and hips. Occupational exposure may also contribute to the development of peripheral and cardiovascular disorders and gastrointestinal problems. In addition, there are more recent data suggesting that occupational exposure to vibration may enhance the risk of developing certain cancers. The aim of this review is to provide an assessment of the occupations where exposure to vibration is most prevalent, and a description of the adverse health effects associated with occupational exposure to vibration. This review will examine (1) various experimental methods used to measure and describe the characteristics of vibration generated by various tools and vehicles, (2) the etiology of vibration-induced disorders, and (3) how these data were employed to assess and improve intervention strategies and equipment that reduces the transmission of vibration to the body. Finally, there is a discussion of the research gaps that need to be investigated to further reduction in the incidence of vibration-induced illnesses and injuries.
Collapse
Affiliation(s)
- Kristine Krajnak
- a Health Effects Laboratory Division , National Institute for Occupational Safety and Health , Morgantown , WV , USA
| |
Collapse
|
9
|
Krajnak K, Miller GR, Waugh S. Contact area affects frequency-dependent responses to vibration in the peripheral vascular and sensorineural systems. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH. PART A 2018; 81:6-19. [PMID: 29173119 PMCID: PMC6379067 DOI: 10.1080/15287394.2017.1401022] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2017] [Accepted: 11/01/2017] [Indexed: 05/18/2023]
Abstract
Repetitive exposure to hand-transmitted vibration is associated with development of peripheral vascular and sensorineural dysfunctions. These disorders and symptoms associated with it are referred to as hand-arm vibration syndrome (HAVS). Although the symptoms of the disorder have been well characterized, the etiology and contribution of various exposure factors to development of the dysfunctions are not well understood. Previous studies performed using a rat-tail model of vibration demonstrated that vascular and peripheral nervous system adverse effects of vibration are frequency-dependent, with vibration frequencies at or near the resonant frequency producing the most severe injury. However, in these investigations, the amplitude of the exposed tissue was greater than amplitude typically noted in human fingers. To determine how contact with vibrating source and amplitude of the biodynamic response of the tissue affects the risk of injury occurring, this study compared the influence of frequency using different levels of restraint to assess how maintaining contact of the tail with vibrating source affects the transmission of vibration. Data demonstrated that for the most part, increasing the contact of the tail with the platform by restraining it with additional straps resulted in an enhancement in transmission of vibration signal and elevation in factors associated with vascular and peripheral nerve injury. In addition, there were also frequency-dependent effects, with exposure at 250 Hz generating greater effects than vibration at 62.5 Hz. These observations are consistent with studies in humans demonstrating that greater contact and exposure to frequencies near the resonant frequency pose the highest risk for generating peripheral vascular and sensorineural dysfunction.
Collapse
Affiliation(s)
- Kristine Krajnak
- a Engineering and Controls Technology Branch , National Institute for Occupational Safety and Health Morgantown , Morgantown , WV , USA
| | - G R Miller
- a Engineering and Controls Technology Branch , National Institute for Occupational Safety and Health Morgantown , Morgantown , WV , USA
| | - Stacey Waugh
- a Engineering and Controls Technology Branch , National Institute for Occupational Safety and Health Morgantown , Morgantown , WV , USA
| |
Collapse
|
10
|
Budd D, House R. Examining the Usefulness of ISO 10819 Anti-Vibration Glove Certification. Ann Work Expo Health 2017; 61:137-140. [PMID: 28395349 DOI: 10.1093/annweh/wxw018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2016] [Accepted: 11/30/2016] [Indexed: 11/14/2022] Open
Abstract
Anti-vibration gloves are commonly worn to reduce hand-arm vibration exposure from work with hand-held vibrating tools when higher priority and more effective controls are unavailable. For gloves to be marketed as 'anti-vibration' they must meet the vibration transmissibility criteria described in the International Organization for Standardization (ISO) standard 10819 (2013). Several issues exist with respect to the methodology used for glove testing as well as the requirements for glove design and composition in ISO 10819 (2013). The true usefulness of anti-vibration gloves at preventing hand-arm vibration syndrome (HAVS) is controversial, given that their performance is dependent on tool vibration characteristics and the anthropometrics of workers in real working conditions. The major risk associated with the use of anti-vibration gloves is that it will give employees and employers a false sense of protection against the negative effects of hand-transmitted vibration. This commentary examines the limitations of the current international standards for anti-vibration glove testing and certification, thereby calling into question the degree of protection that anti-vibration gloves provide against HAVS, and cautioning users to consider both their benefits and potential drawbacks on a case-by-case basis.
Collapse
Affiliation(s)
- Diandra Budd
- Department of Occupational and Environmental Health, St. Michael's Hospital, Toronto, Ontario M5B 1W8, Canada
| | - Ron House
- Department of Occupational and Environmental Health, St. Michael's Hospital, Toronto, Ontario M5B 1W8, Canada
| |
Collapse
|
11
|
Krajnak K, Raju SG, Miller GR, Johnson C, Waugh S, Kashon ML, Riley DA. Long-term daily vibration exposure alters current perception threshold (CPT) sensitivity and myelinated axons in a rat-tail model of vibration-induced injury. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH. PART A 2016; 79:101-111. [PMID: 26852665 DOI: 10.1080/15287394.2015.1104272] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Repeated exposure to hand-transmitted vibration through the use of powered hand tools may result in pain and progressive reductions in tactile sensitivity. The goal of the present study was to use an established animal model of vibration-induced injury to characterize changes in sensory nerve function and cellular mechanisms associated with these alterations. Sensory nerve function was assessed weekly using the current perception threshold test and tail-flick analgesia test in male Sprague-Dawley rats exposed to 28 d of tail vibration. After 28 d of exposure, Aβ fiber sensitivity was reduced. This reduction in sensitivity was partly attributed to structural disruption of myelin. In addition, the decrease in sensitivity was also associated with a reduction in myelin basic protein and 2',3'- cyclic nucleotide phosphodiasterase (CNPase) staining in tail nerves, and an increase in circulating calcitonin gene-related peptide (CGRP) concentrations. Changes in Aβ fiber sensitivity and CGRP concentrations may serve as early markers of vibration-induced injury in peripheral nerves. It is conceivable that these markers may be utilized to monitor sensorineural alterations in workers exposed to vibration to potentially prevent additional injury.
Collapse
Affiliation(s)
- Kristine Krajnak
- a Engineering and Control Technology Branch, Health Effects Laboratory Division , National Institute for Occupational Safety and Health , Morgantown , West Virginia , USA
| | - Sandya G Raju
- b Department of Cell Biology, Neurobiology & Anatomy , Medical College of Wisconsin , Milwaukee , Wisconsin , USA
| | - G Roger Miller
- a Engineering and Control Technology Branch, Health Effects Laboratory Division , National Institute for Occupational Safety and Health , Morgantown , West Virginia , USA
| | - Claud Johnson
- a Engineering and Control Technology Branch, Health Effects Laboratory Division , National Institute for Occupational Safety and Health , Morgantown , West Virginia , USA
| | - Stacey Waugh
- a Engineering and Control Technology Branch, Health Effects Laboratory Division , National Institute for Occupational Safety and Health , Morgantown , West Virginia , USA
| | - Michael L Kashon
- c Biostatistics and Epidemiology Branch, Health Effects Laboratory Division , National Institute for Occupational Safety and Health , Morgantown , West Virginia , USA
| | - Danny A Riley
- b Department of Cell Biology, Neurobiology & Anatomy , Medical College of Wisconsin , Milwaukee , Wisconsin , USA
| |
Collapse
|