1
|
Kim EH, Baek SM, Choi S, Cho J, Tahmasebi S, Bae ON. Promoted coagulant activity and disrupted blood-brain barrier depending on phosphatidylserine externalization of red blood cells exposed to ZnO nanoparticles. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2024; 362:124921. [PMID: 39265764 DOI: 10.1016/j.envpol.2024.124921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2024] [Revised: 09/05/2024] [Accepted: 09/07/2024] [Indexed: 09/14/2024]
Abstract
Zinc oxide nanoparticles (ZnO-NPs) are nanomaterials mainly produced and used worldwide. They translocate to circulatory systems from various exposure routes. While blood and endothelial cells are persistently exposed to circulating ZnO-NPs, the potential risks posed by ZnO-NPs to the cardiovascular system are largely unknown. Our study identified the potential risk of thrombosis and disturbance of the blood-brain barrier (BBB) by coagulant activity on red blood cells (RBCs) caused by ZnO-NPs. ZnO-NPs promoted the externalization of phosphatidylserine and the generation of microvesicles through an imbalance of intracellular mechanisms regulating procoagulant activity in human RBCs. The coagulation cascade leading to thrombin generation was promoted in ZnO-NPs-treated human RBCs. Combined with human RBCs, ZnO-NPs caused coagulant activity on isolated rat RBCs and rat venous thrombosis models. We identified the erythrophagocytosis of RBCs into brain endothelial cells via increased PS exposure induced by ZnO-NPs. Excessive erythrophagocytosis contributes to disrupting the BBB function of endothelial cells. ZnO-NPs increased the procoagulant activity of RBCs, causing venous thrombosis. Excessive erythrophagocytosis through ZnO-NPs-treated RBCs resulted in the dysfunction of BBB. Our study will help elucidate the potential risk ZnO-NPs exert on the cardiovascular system.
Collapse
Affiliation(s)
- Eun-Hye Kim
- College of Pharmacy Institute of Pharmaceutical Science and Technology, Hanyang University, Ansan, 15588, Republic of Korea; Department of Pharmacology and Regenerative Medicine, University of Illinois College of Medicine, Chicago, IL, USA
| | - Seung Mi Baek
- College of Pharmacy Institute of Pharmaceutical Science and Technology, Hanyang University, Ansan, 15588, Republic of Korea
| | - Sungbin Choi
- College of Pharmacy Institute of Pharmaceutical Science and Technology, Hanyang University, Ansan, 15588, Republic of Korea
| | - Junho Cho
- College of Pharmacy Institute of Pharmaceutical Science and Technology, Hanyang University, Ansan, 15588, Republic of Korea
| | - Soroush Tahmasebi
- Department of Pharmacology and Regenerative Medicine, University of Illinois College of Medicine, Chicago, IL, USA
| | - Ok-Nam Bae
- College of Pharmacy Institute of Pharmaceutical Science and Technology, Hanyang University, Ansan, 15588, Republic of Korea.
| |
Collapse
|
2
|
Lippy BE, Brooks SB, Cooper MR, Burrelli LG, Saldivar A, West GH. Characterizing applications, exposure risks, and hazard communication for engineered nanomaterials in construction. Am J Ind Med 2024. [PMID: 38837413 DOI: 10.1002/ajim.23618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Accepted: 05/16/2024] [Indexed: 06/07/2024]
Abstract
BACKGROUND Engineered nanomaterials (ENMs) may pose health risks to workers. Objectives were to characterize ENM applications in construction, identify exposure scenarios, and evaluate the quality of safety data sheets (SDSs) for nano-enabled construction products. METHODS SDSs and product data were obtained from a public database of nano-enabled construction products. Descriptive statistics were calculated for affected trades, product categories, and types of ENMs. A sample of SDSs (n = 33) was evaluated using modified criteria developed by NIOSH researchers. Bulk analysis via transmission electron microscopy characterized nanoparticles in a subset of products. RESULTS Companies report using >50 ENMs in construction products. ENM composition could not be determined via SDSs for 38.1% of the 907 products examined. Polymers and metal oxides tied for most frequently reported ENMs (n = 87, 9.6%). Nano silica, graphene, carbon nanotubes, and silver nanoparticles were also frequently reported. Most of the products were paints and coatings (n = 483, 53.3%), followed by pre-market additives, cementitious materials, insulation, and lubricants. Workers in twenty construction trades are likely to handle nano-enabled products, these particularly encompass cement and brick masons, painters, laborers, carpenters, glaziers, and insulators. A wide range of exposure scenarios were identified. SDSs were classified as satisfactory (18%), in need of improvement (12%), or in need of significant improvement (70%). Bulk analyses revealed discrepancies between actual ENM composition and those in SDSs. DISCUSSION AND CONCLUSION There has been significant progress investigating risks to construction workers posed by ENMs, but SDSs need major improvements. This study provides new insights on the use of ENMs in construction, exposure risks, and hazard communication.
Collapse
Affiliation(s)
- Bruce E Lippy
- Safety and Health Research Department, CPWR-The Center for Construction Research and Training, Silver Spring, Maryland, USA
- The Lippy Group LLC, Catonsville, Maryland, USA
| | - Sara B Brooks
- Safety and Health Research Department, CPWR-The Center for Construction Research and Training, Silver Spring, Maryland, USA
| | - Michael R Cooper
- Safety and Health Research Department, CPWR-The Center for Construction Research and Training, Silver Spring, Maryland, USA
| | | | | | - Gavin H West
- Safety and Health Research Department, CPWR-The Center for Construction Research and Training, Silver Spring, Maryland, USA
| |
Collapse
|
3
|
Anand AS, Jain K, Chauhan A, Prasad DN, Kohli E. Zinc oxide nanoparticles trigger dysfunction of mitochondrial respiratory complexes and repair dynamics in human alveolar cells. Toxicol Ind Health 2023; 39:127-137. [PMID: 36680355 DOI: 10.1177/07482337231152956] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Zinc oxide nanoparticles (ZnO NP) are commonly used engineered NPs with extensive usage in consumer products, thus leading to direct exposure to humans. The direct route of exposure is through inhalation. Once inhaled, these particles accumulate in the lungs, increasing the chances of respiratory tract illness through cellular organelle damage. Zinc oxide nanoparticle-treated lung cells are reported to display cytotoxicity, increase DNA damage, and induce oxidative stress. The current study focused on the effects of ZnO NPs on mitochondrial dynamics (fission and fusion) in human lung epithelial cells (A549). The lung cells were exposed to ZnO NPs at 50 and 100 μg/ml concentrations, and their mitochondrial dynamics were assessed to understand the effects of the NPs. Treatment with ZnO NPs reduced the activity of mitochondrial complex I and complex III and altered mitochondrial structural and functional characteristics in a concentration-dependent manner. Zinc oxide nanoparticles exposure showed an increase in small and round-shaped mitochondria. The expression of various fission proteins (Drp1 and Fis1) and fusion proteins (Mfn1, Mfn2, and OPA1) was altered upon exposure to ZnO NPs. Our studies showed dysfunction of the mitochondria induced by ZnO NPs. In fibroblast mitochondrial dynamics, fission symbolizes threshold damage. In this paper, we have shown that the mitochondrial fission phenotype increased upon exposure to ZnO NPs. The paper emphasizes that these particles enter mitochondria, triggering a stress response that results in the removal of mitochondria via fission. It provides relevant data for safety guidelines to ensure the safer use of these particles.
Collapse
Affiliation(s)
- Avnika Singh Anand
- Neurobiology Division, Defence Institute of Physiology and Allied Sciences, Defence Research and Development Organization, Ministry of Defence, Timarpur, Delhi, India
| | - Khushbu Jain
- Neurobiology Division, Defence Institute of Physiology and Allied Sciences, Defence Research and Development Organization, Ministry of Defence, Timarpur, Delhi, India
| | - Amitabh Chauhan
- Neurobiology Division, Defence Institute of Physiology and Allied Sciences, Defence Research and Development Organization, Ministry of Defence, Timarpur, Delhi, India
| | - Dipti N Prasad
- Neurobiology Division, Defence Institute of Physiology and Allied Sciences, Defence Research and Development Organization, Ministry of Defence, Timarpur, Delhi, India
| | - Ekta Kohli
- Neurobiology Division, Defence Institute of Physiology and Allied Sciences, Defence Research and Development Organization, Ministry of Defence, Timarpur, Delhi, India
| |
Collapse
|
4
|
Gopal J, Hua PY, Muthu M, Wu HF. A MALDI-MS-based impact assessment of ZnO nanoparticles, nanorods and quantum dots on the lipid profile of bacterial pathogens. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 15:87-98. [PMID: 36484165 DOI: 10.1039/d2ay01640k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
MALDI-MS was used for studying the impact of zinc oxide (ZnO) nanomaterials on Pseudomonas aeruginosa and Staphylococcus aureus. The growth patterns of both these bacterial pathogens in the presence of the ZnO nanomaterials and the subsequent lipidomic changes were assessed using an optimized simple, rapid MALDI-MS based methodology. All three nanostructures tested exhibited differential bactericidal activity unique to P. aeruginosa and S. aureus. The results indicated that the ZnO nanomaterials were highly inhibitory to S. aureus even at 70 mg L-1, while in the case of P. aeruginosa, the ZnO nanomaterials were compatible for up to 10 h and beyond 10 h only marginal growth inhibition was observed. The results proved that the shapes of the ZnO nanomaterials did not affect their toxicity properties. MALDI-MS was applied to study the lipidomic changes of P. aeruginosa and S. aureus after nanomaterial treatment, in order to throw light on the mechanism of growth inhibition. The results from the MALDI-MS studies showed that the ZnO nanostructures exhibited only marginal changes in the lipidomic profile both in the case of P. aeruginosa and S. aureus. These preliminary results indicate that the mechanism of growth inhibition by the ZnO nanomaterial is not through lipid-based interactions, but apparently more so via protein inhibitions.
Collapse
Affiliation(s)
- Judy Gopal
- Division of Research and Innovation, Department of Biotechnology, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences (SIMATS), Thandalam, Chennai 602105, Tamil Nadu, India.
| | - Pei-Yang Hua
- Department of Chemistry, National Sun Yat Sen University, Kaohsiung, 804, Taiwan.
| | - Manikandan Muthu
- Division of Research and Innovation, Department of Biotechnology, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences (SIMATS), Thandalam, Chennai 602105, Tamil Nadu, India.
| | - Hui-Fen Wu
- Department of Chemistry, National Sun Yat Sen University, Kaohsiung, 804, Taiwan.
- School of Pharmacy, College of Pharmacy, Kaohsiung Medical University, Kaohsiung, 800, Taiwan
- Center for Nanoscience and Nanotechnology, National Sun Yat-Sen University, Kaohsiung, 804, Taiwan
- Doctoral Degree Program in Marine Biotechnology, National Sun Yat-Sen University, Kaohsiung, 804, Taiwan
| |
Collapse
|
5
|
Sheehan MJ, Vosburgh DJH, O'Shaughnessy PT, Park JH, Sotelo C. Direct-reading instruments for aerosols: A review for occupational health and safety professionals part 2: Applications. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2022; 19:706-729. [PMID: 36197433 DOI: 10.1080/15459624.2022.2132256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Direct reading instruments (DRIs) for aerosols have been used in industrial hygiene practice for many years, but their potential has not been fully realized by many occupational health and safety professionals. Although some DRIs quantify other metrics, this article will primarily focus on DRIs that measure aerosol number, size, or mass. This review addresses three applications of aerosol DRIs that occupational health and safety professionals can use to discern, characterize, and document exposure conditions and resolve aerosol-related problems in the workplace. The most common application of aerosol DRIs is the evaluation of engineering controls. Examples are provided for many types of workplaces and situations including construction, agriculture, mining, conventional manufacturing, advanced manufacturing (nanoparticle technology and additive manufacturing), and non-industrial sites. Aerosol DRIs can help identify the effectiveness of existing controls and, as needed, develop new strategies to reduce potential aerosol exposures. Aerosol concentration mapping (ACM) using DRI data can focus attention on emission sources in the workplace spatially illustrate the effectiveness of controls and constructively convey concerns to management and workers. Examples and good practices of ACM are included. Video Exposure Monitoring (VEM) is another useful technique in which video photography is synced with the concentration output of an aerosol DRI. This combination allows the occupational health and safety professional to see what tasks, environmental situations, and/or worker actions contribute to aerosol concentration and potential exposure. VEM can help identify factors responsible for temporal variations in concentration. VEM can assist with training, engage workers, convince managers about necessary remedial actions, and provide for continuous improvement of the workplace environment. Although using DRIs for control evaluation, ACM and VEM can be time-consuming, the resulting information can provide useful data to prompt needed action by employers and employees. Other barriers to adoption include privacy and security issues in some worksites. This review seeks to provide information so occupational health and safety professionals can better understand and effectively use these powerful applications of aerosol DRIs.
Collapse
Affiliation(s)
- Maura J Sheehan
- Department of Health, West Chester University, West Chester, Pennsylvania
| | - Donna J H Vosburgh
- Department of Occupational & Environmental Safety & Health, University of Wisconsin-Whitewater, Whitewater, Wisconsin
| | | | - Jae Hong Park
- School of Health Sciences, Purdue University, West Lafayette, Indiana
| | | |
Collapse
|
6
|
Vosburgh DJH, Cauda E, O’Shaughnessy PT, Sheehan MJ, Park JH, Anderson K. Direct-reading instruments for aerosols: A review for occupational health and safety professionals part 1: Instruments and good practices. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2022; 19:696-705. [PMID: 36197119 PMCID: PMC10679882 DOI: 10.1080/15459624.2022.2132255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
With advances in technology, there are an increasing number of direct-reading instruments available to occupational health and safety professionals to evaluate occupational aerosol exposures. Despite the wide array of direct-reading instruments available to professionals, the adoption of direct-reading technology to monitor workplace exposures has been limited, partly due to a lack of knowledge on how the instruments operate, how to select an appropriate instrument, and challenges in data analysis techniques. This paper presents a review of direct-reading aerosol instruments available to occupational health and safety professionals, describes the principles of operation, guides instrument selection based on the workplace and exposure, and discusses data analysis techniques to overcome these barriers to adoption. This paper does not cover all direct-reading instruments for aerosols but only those that an occupational health and safety professional could use in a workplace to evaluate exposures. Therefore, this paper focuses on instruments that have the most potential for workplace use due to their robustness, past workplace use, and price with regard to return on investment. The instruments covered in this paper include those that measure aerosol number concentration, mass concentration, and aerosol size distributions.
Collapse
Affiliation(s)
- Donna J. H. Vosburgh
- Department of Occupational & Environmental Safety & Health, University of Wisconsin-Whitewater, Whitewater, Wisconsin
| | - Emanuele Cauda
- Pittsburgh Mining Research Division, National Institute for Occupational Safety and Health, Pittsburgh, Pennsylvania
| | | | - Maura J. Sheehan
- Department of Health, West Chester University, West Chester, Pennsylvania
| | - Jae Hong Park
- School of Health Sciences, Purdue University, West Lafayette, Indiana
| | - Kimberly Anderson
- Respiratory Health Division, National Institute for Occupational Safety and Health, Morgantown, West Virginia
| |
Collapse
|
7
|
Saber AT, Hadrup N, Williams A, Mortensen A, Szarek J, Kyjovska Z, Kurz A, Jacobsen NR, Wallin H, Halappanavar S, Vogel U. Unchanged pulmonary toxicity of ZnO nanoparticles formulated in a liquid matrix for glass coating. Nanotoxicology 2022; 16:812-827. [PMID: 36480659 DOI: 10.1080/17435390.2022.2152751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The inclusion of nanoparticles can increase the quality of certain products. One application is the inclusion of Zinc oxide (ZnO) nanoparticles in a glass coating matrix to produce a UV-absorbing coating for glass sheets. Yet, the question is whether the inclusion of ZnO in the matrix induces toxicity at low exposure levels. To test this, mice were given single intratracheal instillation of 1) ZnO powder (ZnO), 2) ZnO in a glass matrix coating in its liquid phase (ZnO-Matrix), and 3) the matrix with no ZnO (Matrix). Doses of ZnO were 0.23, 0.67, and 2 µg ZnO/mouse. ZnO Matrix doses had equal amounts of ZnO, while Matrix was adjusted to have an equal volume of matrix as ZnO Matrix. Post-exposure periods were 1, 3, or 28 d. Endpoints were pulmonary inflammation as bronchoalveolar lavage (BAL) fluid cellularity, genotoxicity in lung and liver, measured by comet assay, histopathology of lung and liver, and global gene expression in lung using microarrays. Neutrophil numbers were increased to a similar extent with ZnO and ZnO-Matrix at 1 and 3 d. Only weak genotoxicity without dose-response effects was observed in the lung. Lung histology showed an earlier onset of inflammation in material-exposed groups as compared to controls. Microarray analysis showed a stronger response in terms of the number of differentially regulated genes in ZnO-Matrix exposed mice as compared to Matrix only. Activated canonical pathways included inflammatory and cardiovascular ones. In conclusion, the pulmonary toxicity of ZnO was not changed by formulation in a liquid matrix for glass coating.
Collapse
Affiliation(s)
| | - Niels Hadrup
- National Research Centre for the Working Environment (NFA), Copenhagen, Denmark.,Division of Diet, Disease Prevention and Toxicology, National Food Institute, Technical University of Denmark, Copenhagen, Denmark
| | - Andrew Williams
- Environmental Health Science and Research Bureau, Health Canada, Ottawa, Canada
| | - Alicja Mortensen
- National Research Centre for the Working Environment (NFA), Copenhagen, Denmark
| | - Jozef Szarek
- Department of Pathophysiology, Forensic Veterinary Medicine and Administration, University of Warmia and Mazury in Olsztyn, Olsztyn, Poland
| | - Zdenka Kyjovska
- National Research Centre for the Working Environment (NFA), Copenhagen, Denmark
| | | | | | - Håkan Wallin
- National Institute of Occupational Health, Oslo, Norway
| | - Sabina Halappanavar
- Environmental Health Science and Research Bureau, Health Canada, Ottawa, Canada
| | - Ulla Vogel
- National Research Centre for the Working Environment (NFA), Copenhagen, Denmark.,DTU Food, Technical University of Denmark, Lyngby, Denmark
| |
Collapse
|
8
|
Hatch AC, Peloquin D, Kumbar AS, Luxton TP, Clar JG. Transformation of zinc oxide nanoparticles in synthetic lung fluids. JOURNAL OF NANOPARTICLE RESEARCH : AN INTERDISCIPLINARY FORUM FOR NANOSCALE SCIENCE AND TECHNOLOGY 2022; 24:153. [PMID: 35873670 PMCID: PMC9288259 DOI: 10.1007/s11051-022-05527-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Accepted: 06/30/2022] [Indexed: 06/15/2023]
Abstract
UNLABELLED Surface coatings, including paints, stains, and sealants, have recently become a focus of "nano-enabled" consumer product engineering. Specifically, zinc oxide (ZnO) nanoparticles (NPs) have been introduced to surface coatings to increase UV resistance. As more "nano-enabled" products are made available for purchase, questions arise regarding their long-term environmental and human health effects. This study tracked the transformation of NP additives commonly added to consumer paints and stains using ZnO NPs as a model system. During product application and use, there is a risk of inhalation of aerosolized ZnO NPs. To investigate the potential chemical interactions and transformations that would occur after inhalation, ZnO NPs were incubated in two synthetic lung fluids (SLFs). Initial studies utilized ZnO NPs dispersed in Milli-Q water (control), or a commercially available deck stain. Additionally, two commercially available products advertising the inclusion of ZnO NP additives were evaluated. Subsamples were taken throughout incubation and analyzed via atomic absorption spectroscopy to determine both the total (including particulate) zinc concentration and dissolved (non-particulate) zinc concentration. Results indicate that the vast majority of ZnO transformation takes place within the first 24 h of incubation and is primarily driven by SLF pH and composition complexity. Significant dissolution of ZnO NPs was observed when incubated in Gamble's solution (between 25 and 68% depending on the matrix. Additionally, all ZnO solutions saw near immediate dissolution (~ 98-100%) within 3 h of incubation in artificial lysosomal fluid. Results illustrate potential for NPs in consumer products to undergo significant transformation during use and exposure over short time periods. SUPPLEMENTARY INFORMATION The online version contains supplementary material available at 10.1007/s11051-022-05527-y.
Collapse
Affiliation(s)
- Avery C Hatch
- Department of Chemistry, Elon University, Elon, NC 27244 USA
| | - Derek Peloquin
- Oak Ridge Institute for Science and Education (ORISE) Postdoctoral Research Associate, Oak Ridge, USA
| | - Amar S Kumbar
- Analytical and Nanofabrication Laboratory, University of North Carolina, Chapel Hill, NC 27599 USA
| | - Todd P Luxton
- Center for Environmental Solutions and Environmental Response, Office of Research and Development, U.S. Environmental Protection Agency, 5995 Center Hill Avenue, Cincinnati, OH 45224 USA
| | - Justin G Clar
- Department of Chemistry, Elon University, Elon, NC 27244 USA
| |
Collapse
|
9
|
Indirect mediators of systemic health outcomes following nanoparticle inhalation exposure. Pharmacol Ther 2022; 235:108120. [PMID: 35085604 PMCID: PMC9189040 DOI: 10.1016/j.pharmthera.2022.108120] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Accepted: 01/19/2022] [Indexed: 02/07/2023]
Abstract
The growing field of nanoscience has shed light on the wide diversity of natural and anthropogenic sources of nano-scale particulates, raising concern as to their impacts on human health. Inhalation is the most robust route of entry, with nanoparticles (NPs) evading mucociliary clearance and depositing deep into the alveolar region. Yet, impacts from inhaled NPs are evident far outside the lung, particularly on the cardiovascular system and highly vascularized organs like the brain. Peripheral effects are partly explained by the translocation of some NPs from the lung into the circulation; however, other NPs largely confined to the lung are still accompanied by systemic outcomes. Omic research has only just begun to inform on the complex myriad of molecules released from the lung to the blood as byproducts of pulmonary pathology. These indirect mediators are diverse in their molecular make-up and activity in the periphery. The present review examines systemic outcomes attributed to pulmonary NP exposure and what is known about indirect pathological mediators released from the lung into the circulation. Further focus was directed to outcomes in the brain, a highly vascularized region susceptible to acute and longer-term outcomes. Findings here support the need for big-data toxicological studies to understand what drives these health outcomes and better predict, circumvent, and treat the potential health impacts arising from NP exposure scenarios.
Collapse
|
10
|
Biomonitoring of Urinary Nickel Successfully Protects Employees and Introduces Effective Interventions. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19084887. [PMID: 35457753 PMCID: PMC9032121 DOI: 10.3390/ijerph19084887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 04/14/2022] [Accepted: 04/15/2022] [Indexed: 02/01/2023]
Abstract
Nickel is a heavy metal used in many industries. Nickel exposure can induce respiratory diseases and allergic reactions, and increase cancer risk. This study evaluated the introduction of a grinding and polishing system to prevent injuries from nickel toxicity in workers. We performed a controlled, interventional, before-and-after study from January 2018 to December 2019 at a faucet component industrial manufacturing site. Results from workplace environmental monitoring, questionnaire responses, and biomonitoring were collected before and after the intervention. Thirty-seven workers (100% men) aged 25.0 (interquartile range (IQR): 22.0–33.5) years were categorized into two groups, those with and without nickel exposure. In the exposed group, the median exposure time was 18.0 months (IQR 14.0–20.0 months). Urinary nickel concentration was lower in the exposed group than in the non-exposed group (13.8 (IQR 1.7–20.7); 23.1 (IQR 11.3–32.8) μg/g creatinine, respectively; p = 0.047). The median urinary nickel concentration was lower in the second year than in the first year (17.4 (IQR 2.2–27.4), 7.7 (IQR 4.3–18.5) μg/g creatinine, respectively; p = 0.022). Significant reductions in urinary nickel concentration were observed following the intervention and educational program. Thus, biomonitoring of urinary nickel concentration can successfully reflect the effectiveness of interventions and their relationship to nickel exposure.
Collapse
|
11
|
West GH, Castaneda FI, Burrelli LG, Dresser D, Cooper MR, Brooks SB, Lippy BE. Occupational exposure risk during spraying of biocidal paint containing silver nanoparticles. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2021; 18:237-249. [PMID: 33989130 DOI: 10.1080/15459624.2021.1910277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The study assessed potential to exceed occupational exposure limits while spraying paint with and without a silver nanoparticle biocidal additive. A tradesperson performed the tasks in a sealed chamber with filtered air supply. Integrated air sampling entailed transmission electron microscopy with energy dispersive X-ray analysis, direct-reading of particle number concentrations, and determination of silver mass concentration by NIOSH Method 7300. Silver nanoparticles were primarily embedded in paint spray droplets but also observed as isolated particles. Using an α-level of 0.05, median nanoparticle number concentrations did not differ significantly when spraying conventional vs. biocidal paint, although statistically significant differences were observed at specific particle size ranges <100 nm. The geometric mean concentration of total silver while spraying biocidal paint (n = 6) was 2.1 µg/m3 (95% CI: 1.5-2.8 µg/m3), and no respirable silver was detected (<0.50 µg/m3). The results address a lack of silver nanoparticle exposure data in construction and demonstrate the feasibility of a practical sampling approach. Given similar conditions, the measurements suggest a low probability of exceeding a proposed silver nanoparticle exposure limit of 0.9 µg/m3 as an airborne 8-hr time-weighted average respirable mass concentration. A full workday of exposure to respirable silver at the highest possible level in this study (<0.50 µg/m3) would not exceed the exposure limit, although limitations in comparing short task-based exposures to an 8-hr exposure limit must be noted. There was airflow in the study chamber, whereas exposure levels could increase over time in work environments lacking adequate ventilation. Potential to exceed the exposure limit hinged upon the respirable fraction of the paint mist, which could vary by material and application method. Additional research would improve understanding of silver nanoparticle exposure risks among construction trades, and biological responses to these exposures. Given the potential for exposure variability on construction jobsites, safety and health professionals should be cognizant of methods to assess and control silver nanoparticle exposures.
Collapse
Affiliation(s)
- Gavin H West
- CPWR - The Center for Construction Research and Training, Silver Spring, Maryland
| | - Fatima I Castaneda
- Environmental Profiles, Inc, Columbia, Maryland
- Department of Environmental Health and Engineering, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland
| | | | | | - Michael R Cooper
- CPWR - The Center for Construction Research and Training, Silver Spring, Maryland
| | - Sara B Brooks
- CPWR - The Center for Construction Research and Training, Silver Spring, Maryland
| | - Bruce E Lippy
- CPWR - The Center for Construction Research and Training, Silver Spring, Maryland
| |
Collapse
|
12
|
Vimercati L, Cavone D, Caputi A, De Maria L, Tria M, Prato E, Ferri GM. Nanoparticles: An Experimental Study of Zinc Nanoparticles Toxicity on Marine Crustaceans. General Overview on the Health Implications in Humans. Front Public Health 2020; 8:192. [PMID: 32509719 PMCID: PMC7253631 DOI: 10.3389/fpubh.2020.00192] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2019] [Accepted: 04/27/2020] [Indexed: 01/05/2023] Open
Abstract
The presence of products containing nanoparticles or nanofibers is rapidly growing. Nanotechnology involves a wide spectrum of industrial fields. There is a lack of information regarding the toxicity of these nanoparticles in aqueous media. The potential acute toxicity of ZnO NPs using two marine crustacean species: the copepod Tigriopus fulvus and the amphypod Corophium insidiosum was evaluated. Acute tests were conducted on adults of T. Fulvus nauplii and C. insidiosum. Both test species were exposed for 96 h to 5 increasing concentrations of ZnO NPs and ZnSO4H2O, and the endpoint was mortality. Statistical analysis revealed that the mean LC50 values of both ZnO NPs and ZnSO4H2O (ZnO NPs: F = 59.42; P < 0.0015; ZnSO4H2O: F = 25.57; P < 0.0015) were significantly lower for Tigriopus fulvus than for Corophium insidiosum. This result confirms that the toxic effect could be mainly attributed to the Zn ions, confirming that the dissolution processes play a crucial role in the toxicity of the ZnO NPs.
Collapse
Affiliation(s)
- Luigi Vimercati
- Unit of Occupational Medicine, Interdisciplinary Department of Medicine (DIM), School of Medicine, University Hospital “Policlinico”, University of Bari “A. Moro”, Bari, Italy
| | - Domenica Cavone
- Unit of Occupational Medicine, Interdisciplinary Department of Medicine (DIM), School of Medicine, University Hospital “Policlinico”, University of Bari “A. Moro”, Bari, Italy
| | - Antonio Caputi
- Unit of Occupational Medicine, Interdisciplinary Department of Medicine (DIM), School of Medicine, University Hospital “Policlinico”, University of Bari “A. Moro”, Bari, Italy
| | - Luigi De Maria
- Unit of Occupational Medicine, Interdisciplinary Department of Medicine (DIM), School of Medicine, University Hospital “Policlinico”, University of Bari “A. Moro”, Bari, Italy
| | - Michele Tria
- Marine Environment and Pollution Prevention, Department of Prevention, ASL TA Health Company, Taranto, Italy
| | - Ermelinda Prato
- Institute for the Coastal Marine Environment of the Italian National Research Council (IAMC-CNR), Taranto, Italy
| | - Giovanni Maria Ferri
- Unit of Occupational Medicine, Interdisciplinary Department of Medicine (DIM), School of Medicine, University Hospital “Policlinico”, University of Bari “A. Moro”, Bari, Italy
| |
Collapse
|
13
|
West GH, Cooper MR, Burrelli LG, Dresser D, Lippy BE. Exposure to airborne nano-titanium dioxide during airless spray painting and sanding. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2019; 16:218-228. [PMID: 30451647 DOI: 10.1080/15459624.2018.1550295] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
The objectives of the study were to measure and characterize exposure to airborne nanoscale titanium dioxide during airless spraying and sanding of a nano-enabled paint, and to evaluate the effectiveness of dust capture methods in reducing airborne nanoparticle concentrations. A tradesperson performed the work activities in an environmentally controlled chamber. Samples were collected in the tradesperson's breathing zone and in surrounding areas to assess bystander exposure. Filter-based samples were analyzed using gravimetric methods, scanning electron microscopy, and energy dispersive spectroscopy. Differential particle count data were obtained by means of a scanning mobility particle sizer. Local exhaust ventilation provided statistically significant reductions of airborne nanoparticle concentrations during sanding. Sanding the paint after drying with a handheld power sander generated relatively low levels of airborne titanium dioxide. In contrast, task-based exposure measurements collected during the initial airless spray application of the nano-enabled paint suggested a potential for occupational exposures to exceed the time-weighted average exposure limit for ultrafine titanium dioxide recommended by the National Institute for Occupational Safety and Health. Painters applying nano-enabled coatings may have little recourse but to rely, in some instances, on lower tiers of the hierarchy of controls, such as personal protective equipment. In light of these findings, employers and industrial hygienists should characterize exposures and implement the hierarchy of controls to ensure painters are sufficiently protected.
Collapse
Affiliation(s)
- Gavin H West
- a CPWR - The Center for Construction Research and Training , Silver Spring , Maryland
| | - Michael R Cooper
- a CPWR - The Center for Construction Research and Training , Silver Spring , Maryland
| | | | | | - Bruce E Lippy
- a CPWR - The Center for Construction Research and Training , Silver Spring , Maryland
| |
Collapse
|
14
|
Nored AW, Chalbot MCG, Kavouras IG. Characterization of paint dust aerosol generated from mechanical abrasion of TiO 2-containing paints. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2018; 15:629-640. [PMID: 29856686 DOI: 10.1080/15459624.2018.1484126] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The purpose of the study was to determine the potential for release of titanium dioxide nanoparticles in paint dust. The coatings aerosol resuspension system was developed and used for testing the generation and physical, chemical, and morphological properties of paint dust particles from mechanical abrasion (i.e., sanding) of coated wood surfaces. The paint dust emissions from bare and coated wood surfaces with multiple coatings using variable sandpaper grits were evaluated. Substantially higher particle number concentrations were measured for paint dust containing particles in the nano range (particles with aerodynamic diameter less than 100 nm) than those measured for wood dust. The variability of particle number concentration and size distribution of paint dust derived under different conditions indicated that considerable quantities of nanoparticles might be released from mechanical abrasion of painted surfaces that may induce unhealthy exposure conditions. Moreover, spectroscopic and microscopic analysis identified the presence of paint and wood components in paint dust, including titanium dioxide agglomerates that were originally embedded in the paint. The agglomerates were mostly attached to particles with sizes <100 nm, enabling them to potentially penetrate into the lower respiratory tract. These results demonstrated that the paint dust exposure generation system can provide qualitative and quantitative information on particle emissions and the abundance of nanoparticles from paint sanding in realistic conditions and they may be used to assess occupational and environmental exposures and risks. Furthermore, the prevalence of titanium dioxide nanoparticles in paint dust highlights the potential for exposures of painters and other occupational groups to hazardous paint dust and the need for protective devices and strategies aiming to reduce exposures to nanoparticles.
Collapse
Affiliation(s)
- Adam W Nored
- a Interdisciplinary Engineering Program , University of Alabama at Birmingham , Birmingham , Alabama
| | | | - Ilias G Kavouras
- c Department of Environmental, Occupational and Geospatial Health Sciences , City University of New York , New York , New York
| |
Collapse
|