1
|
Puijk R, Puijk RH, Laende EK, Dunbar MJ, Plevier JWM, Nolte PA, Pijls BGCW. 6-month migration sufficient for evaluation of total knee replacements: a systematic review and meta-analysis. Acta Orthop 2023; 94:577-587. [PMID: 38038237 PMCID: PMC10690979 DOI: 10.2340/17453674.2023.24579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2023] [Accepted: 10/22/2023] [Indexed: 12/02/2023] Open
Abstract
BACKGROUND AND PURPOSE This updated meta-analysis evaluates the migration pattern of the tibial component of primary total knee replacements measured with radiostereometric analysis (RSA). We aimed to evaluate whether 6-month maximum total point motion (MTPM) values could be used instead of 1-year MTPM for RSA threshold testing and to present the pooled migration patterns for different implant designs that can be used as a benchmark. PATIENTS AND METHODS The search included all published RSA studies on migration patterns of tibial components until 2023. Study groups were classified according to their prosthesis brand, fixation, and insert (PFI). Sub-analyses were performed to compare the mean tibial component migration patterns of different implant variables, stratified according to fixation. RESULTS 96 studies (43 new studies), including 197 study groups and 4,706 knees, were included. Most migration occurred within the first 6 postoperative months (126 study groups: mean 0.58 mm, 95% confidence interval [CI] 0.50-0.65), followed by minimal migration between 6 and 12 months (197 study groups: mean 0.04 mm, CI 0.03-0.06), irrespective of the fixation method used. Distinct migration patterns were observed among the different fixation methods. No differences were found in migration patterns among cemented components in any of the sub-group analyses conducted. For uncemented implants, trabecular metal surfaced components seemed to migrate less than porous-coated or uncoated components Conclusion: Based on the small difference between MTPM values at 6 months and 1 year, MTPM at 6 months could be used instead of MTPM at 1 year for RSA threshold testing. The pooled migration patterns can be used as benchmark for evaluation of new implants by defining fixation-specific RSA thresholds when combined with implant survival.
Collapse
Affiliation(s)
- Raymond Puijk
- Department of Orthopaedics, Spaarne Gasthuis, Hoofddorp, the Netherlands.
| | - Rowan H Puijk
- Department of Orthopaedics, Spaarne Gasthuis, Hoofddorp, the Netherlands
| | - Elise K Laende
- Mechanical and Materials Engineering, Queen's University, Kingston, Ontario, Canada; Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
| | - Michael J Dunbar
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada; School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - José W M Plevier
- Walaeus Library, Leiden University Medical Center, Leiden, The Netherlands
| | - Peter A Nolte
- Department of Orthopaedics, Spaarne Gasthuis, Hoofddorp, the Netherlands; Department of Oral Cell Biology, Academic Centre for Dentistry (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
| | - Bart G C W Pijls
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
2
|
Andersen MR, Winther N, Lind T, Schrøder H, Flivik G, Petersen MM. Tibial Component Undersizing Is Related to High Degrees of Implant Migration Following Cementless Total Knee Arthroplasty: A Study of Radiostereometric Analysis Data for 111 Patients with 2-Year Follow-up. JB JS Open Access 2023; 8:e23.00032. [PMID: 37575962 PMCID: PMC10412432 DOI: 10.2106/jbjs.oa.23.00032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/15/2023] Open
Abstract
Radiostereometric analysis (RSA) studies have shown that the continuous migration of tibial components is predictive of aseptic loosening following total knee arthroplasty (TKA). In the present study, we investigated whether accurate sizing and placement of tibial components are related to the degree of implant migration as measured with use of RSA. Methods A total of 111 patients who underwent TKA surgery with a cementless tibial component were followed for a period of 2 years postoperatively, during which implant migration was assessed with use of RSA. RSA was performed within 7 days postoperatively and after 3, 6, 12, and 24 months. Postoperative radiographs were evaluated for component size and placement in the tibia. The evaluations were performed by experienced knee surgeons who were blinded to the migration data and clinical outcomes. A multivariable linear regression analysis was conducted. Results Continuous implant migration (i.e., migration occurring between 12 and 24 months postoperatively) had a negative association with tibial component size (coefficient [B], -0.2; 95% confidence interval [CI], -0.33 to -0.08). Subsidence was associated with the absence of posterior cortical bone support (B, -0.7; 95% CI, -1.09 to -0.28), the absence of lateral cortical bone support (B, 0.8; 95% CI, 0.29 to 1.37), frontal-plane varus malalignment (B, 0.6; 95% CI, 0.12 to 1.16), and component undersizing (B, -0.4; 95% CI, -0.06 to -0.68). Posterior tilt was associated only with undersizing (B, 0.6; 95% CI, 0.27 to 1.11). Conclusions Undersized cementless tibial components are at a higher risk for poor fixation with continuous migration following TKA. Therefore, a higher risk of aseptic loosening should be expected. Level of Evidence Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Mikkel Rathsach Andersen
- Department of Orthopedics, Herlev-Gentofte Hospital, University of Copenhagen, Copenhagen, Denmark
| | - Nikolaj Winther
- Department of Orthopedics, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark
| | - Thomas Lind
- Department of Orthopedics, Herlev-Gentofte Hospital, University of Copenhagen, Copenhagen, Denmark
| | - Henrik Schrøder
- Department of Orthopedics, Næstved Sygehus, Syddansk Universitet, Odense, Denmark
| | - Gunnar Flivik
- Department of Orthopedics, Skåne University Hospital, Lund University, Lund, Sweden
| | - Michael Mørk Petersen
- Department of Orthopedics, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
3
|
Quevedo González FJ, Sculco PK, Kahlenberg CA, Mayman DJ, Lipman JD, Wright TM, Vigdorchik JM. Undersizing the Tibial Baseplate in Cementless Total Knee Arthroplasty has Only a Small Impact on Bone-Implant Interaction: A Finite Element Biomechanical Study. J Arthroplasty 2023; 38:757-762. [PMID: 36280162 DOI: 10.1016/j.arth.2022.10.032] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 10/14/2022] [Accepted: 10/18/2022] [Indexed: 11/06/2022] Open
Abstract
BACKGROUND The tibial component in total knee arthroplasty (TKA) is often chosen to maximize coverage of the tibial cut, which can result in excessive internal rotation of the component. Optimal rotational alignment may require a smaller baseplate with suboptimal coverage that could threaten fixation. We asked: "does undersizing the tibial component of a cementless TKA to gain external rotation increase the risk of bone failure?" METHODS We developed computational finite element (FE) analysis models from the computed tomography (CT) scans of 12 patients scheduled for primary TKA. The models were implanted with a cementless tibial baseplate that maximized coverage and one or two sizes smaller and externally rotated by 5°. We calculated the risk of bone collapse under loads representative of stair ascent. RESULTS Undersizing the implant increased the area at risk of collapse for eight patients. However, the area at risk of collapse for the undersized implant (range, 5.2%-16.4%) was no different (P = .24) to the optimally sized implant (range, 4.5%-17.9%). The bone at risk of collapse was concentrated along the posterior edge of the implant. The area at risk of collapse was not proportional to implant size, and for four subjects undersizing the implant actually decreased the area at risk of collapse. CONCLUSION While implants should maximize coverage of the tibial cut and seek support on dense bone, undersizing the tibial component to gain external rotation had minimal impact on the load transfer to the underlying bone. This FE analysis model of a cementless tibial baseplate may require further validation and additional studies to investigate the long-term biomechanical effects of undersizing the tibial baseplate. In conclusion, while surgeons should strive to use the appropriate tibial baseplate for each patient, our model identified only minor biomechanical consequences of undersizing the implant for the immediate postoperative bone-implant interaction and implant subsidence.
Collapse
Affiliation(s)
| | - Peter K Sculco
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | - Cynthia A Kahlenberg
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | - David J Mayman
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | - Joseph D Lipman
- Department of Biomechanics, Hospital for Special Surgery, New York, New York
| | - Timothy M Wright
- Department of Biomechanics, Hospital for Special Surgery, New York, New York
| | - Jonathan M Vigdorchik
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| |
Collapse
|
4
|
Trabecular metal monoblock versus modular tibial trays in total knee arthroplasty: meta-analysis of randomized control trials. INTERNATIONAL ORTHOPAEDICS 2022; 46:2509-2516. [PMID: 36031663 PMCID: PMC9556340 DOI: 10.1007/s00264-022-05553-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Accepted: 08/10/2022] [Indexed: 01/04/2023]
Abstract
PURPOSE Total knee arthroplasty is one of the significantly evolving procedures with different knee designs available in the market. The continued development of these prosthesis resulted in improvement of the implant survivorship and patient satisfaction. This study is an RCT-based meta-analysis aimed to compare two designs of total knee replacement: the conventional modular and the monoblock trabecular metal tibial trays. METHODS This meta-analysis was performed by a literature review according to the PRISMA guidelines. A detailed search of the English literature was done using the PubMed, Medline, CINAHL, Cochrane, Embase, and Google Scholar databases. Only randomized control trials were included in the analysis after ensuring homogeneity. RevMan V.5.0.18.33 (The Cochrane Collaboration, Copenhagen, Denmark) was used to perform the meta-analysis. Extracted outcome measures were Knee Society score, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, survivorship, complication rate, and radiostereographic analysis. RESULTS Seven randomized control trials with 635 patients were eligible for our analysis after they met our inclusion criteria. Three hundred twelve patients received monoblock tibias, and the other 323 patients received modular tibial trays during their total knee arthroplasty surgeries. There were statistically significant superiority of the modular knees in the functional Knee Society and WOMAC scores at five years (P = 0.003 and 0.05, respectively). The modular design was also more stable on RSA at two years (P < 0.0001). CONCLUSION Modular and monoblock tibial trays are comparable knee designs with comparable survivorship and complication rates. However, the modular knees had better mid-term functional outcome and are more stable on radiostereographic analysis.
Collapse
|
5
|
Laende EK, Mills Flemming J, Astephen Wilson JL, Cantoni E, Dunbar MJ. The associations of implant and patient factors with migration of the tibial component differ by sex : a radiostereometric study on more than 400 total knee arthroplasties. Bone Joint J 2022; 104-B:444-451. [PMID: 35360938 DOI: 10.1302/0301-620x.104b4.bjj-2021-1247.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS Thresholds of acceptable early migration of the components in total knee arthroplasty (TKA) have traditionally ignored the effects of patient and implant factors that may influence migration. The aim of this study was to determine which of these factors are associated with overall longitudinal migration of well-fixed tibial components following TKA. METHODS Radiostereometric analysis (RSA) data over a two-year period were available for 419 successful primary TKAs (267 cemented and 152 uncemented in 257 female and 162 male patients). Longitudinal analysis of data using marginal models was performed to examine the associations of patient factors (age, sex, BMI, smoking status) and implant factors (cemented or uncemented, the size of the implant) with maximum total point motion (MTPM) migration. Analyses were also performed on subgroups based on sex and fixation. RESULTS In the overall group, only fixation was significantly associated with migration (p < 0.001). For uncemented tibial components in males, smoking was significantly associated with lower migration (p = 0.030) and BMI approached significance (p = 0.061). For females with uncemented components, smoking (p = 0.081) and age (p = 0.063) approached significance and were both associated with increased migration. The small number of self-reported smokers in this study warrants cautious interpretation and further investigation. For cemented components in females, larger sizes of tibial component were significantly associated with increased migration (p = 0.004). No factors were significant for cemented components in males. CONCLUSION The migration of uncemented tibial components was more sensitive to patient factors than cemented implants. These differences were not consistent by sex, suggesting that it may be of value to evaluate female and male patients separately following TKA. Cite this article: Bone Joint J 2022;104-B(4):444-451.
Collapse
Affiliation(s)
- Elise K Laende
- School of Biomedical Engineering, Dalhousie University, Halifax, Canada.,Division of Orthopaedics, Department of Surgery, Dalhousie University, Halifax, Canada.,Queen Elizabeth II Health Sciences Centre, Nova Scotia Health Authority, Halifax, Canada
| | | | - Janie L Astephen Wilson
- School of Biomedical Engineering, Dalhousie University, Halifax, Canada.,Department of Surgery, Dalhousie University, Halifax, Canada
| | - Eva Cantoni
- Research Center for Statistics and Geneva School of Economics and Management, University of Geneva, Geneva, Switzerland
| | - Michael J Dunbar
- School of Biomedical Engineering, Dalhousie University, Halifax, Canada.,Division of Orthopaedics, Department of Surgery, Dalhousie University, Halifax, Canada.,Queen Elizabeth II Health Sciences Centre, Nova Scotia Health Authority, Halifax, Canada
| |
Collapse
|
6
|
Torle J, Thillemann JK, Petersen ET, Madsen F, Søballe K, Stilling M. Less polyethylene wear in monobloc compared to modular ultra-high-molecular-weight-polyethylene inlays in hybrid total knee arthroplasty: A 5-year randomized radiostereometry study. Knee 2021; 29:486-499. [PMID: 33743263 DOI: 10.1016/j.knee.2021.02.033] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 11/19/2020] [Accepted: 02/22/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND A modular polyethylene (PE) inlay in total knee arthroplasty (TKA) may wear on both sides. PE particles may induce osteolysis, which can lead to implant loosening. The aim of this study was to determine if PE wear in monobloc TKA differs from that ofmodular TKA at 60-month follow-up. PATIENTS AND METHODS In a prospective, patient-blinded trial, 50 patients were randomized to hybrid TKA surgery with either acementless high-porosity trabecular-metal tibial component with a monobloc UHMWPE inlay (MONO-TM) or a cementless low-porosity screw-augmented titanium fiber-mesh tibial component with a modular UHMWPE inlay (MODULAR-FM). Radiostereometry was used to measure PE wear and tibial component migration. RESULTS At 60-monthfollow-up, mean PE wear of the medial compartment was 0.24 mm and 0.61 mm and mean PE wear of the lateral compartment was 0.31 mm and 0.82 mm for the MONO-TM and the MODULAR-FM groups, respectively (p < 0.01). The PE wear-rate was 0.05 mm (95% CI 0.03-0.08) in the MONO-TM group and 0.14 mm (95% CI 0.12-0.17) in the MODULAR-FM group (p < 0.01). Total translation at 60 months was mean 0.30 mm (95% CI 0.10-0.51) less (p < 0.01) for MONO-TM compared with MODULAR-FM tibial components. The majority of tibial components were stable (<0.2 mm MTPM) from 12 to 24-month and 24 to 60-month follow-up. CONCLUSION At mid-term follow-up, monobloc PE inlay wear was approximately 40% of that of the modular PE inlay wear, which suggest that back-side wear of modular PE inlays is a significant contributor of PE wear in hybrid TKA.
Collapse
Affiliation(s)
- Johan Torle
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.
| | - Janni Kjærgaard Thillemann
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark; Department of Orthopeadics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro, Denmark
| | - Emil Toft Petersen
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark; Department of Orthopeadics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro, Denmark
| | - Frank Madsen
- Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark
| | - Kjeld Søballe
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark
| | - Maiken Stilling
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark; Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
7
|
Rathsach Andersen M, Winther N, Lind T, Schrøder HM, Petersen MM. Bone remodeling of the proximal tibia after uncemented total knee arthroplasty: secondary endpoints analyzed from a randomized trial comparing monoblock and modular tibia trays-2 year follow-up of 53 cases. Acta Orthop 2019; 90:479-483. [PMID: 31269876 PMCID: PMC6746298 DOI: 10.1080/17453674.2019.1637178] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Bone remodeling as a response to bone trauma, postoperative immobilization, and device-related bone reactions can lead to loss of bone stock and increase the risk of periprosthetic fracture and aseptic loosening. This study investigates the adaptive bone remodeling of the proximal tibia after uncemented total knee arthroplasty (TKA). Patients and methods - We performed a 2-year follow up of 53 patients (mean age 62 (38-70) years, 27 of whom were men, who received an uncemented TKA in a randomized controlled trial with bone mineral density (BMD) as secondary endpoint. Patients were randomized to 2 groups of either monoblock (A) or modular (B) polyethylene design. The TKAs were performed using the uncemented Zimmer Nexgen trabecular metal. Measurements of BMD were done postoperatively and after 3, 6, 12, and 24 months. BMD was measured in 3 regions of interest (ROI). Results and interpretation - In group A statistically significant changes in BMD were seen after 24 months in both the medial and lateral ROI. BMD decreased medially by 15% (p = 0.004) and laterally by 13% (p = 0.01). In group B the BMD changes were limited and after 24 months returned to the preoperative values. The differences in BMD change between groups were statistically significant in both the medial (p = 0.03) and lateral (p = 0.02) ROI. In the distal ROI we found no significant change in BMD in either group. A significantly different bone remodeling pattern of the proximal tibia was seen in the 2 groups with a higher degree of bone loss in the knees that received the monoblock polyethylene design, indicating that the flexible monoblock implant design, previously shown to improve fixation, does not decrease the bone loss of the proximal tibia.
Collapse
Affiliation(s)
- Mikkel Rathsach Andersen
- Department of Orthopedics, Rigshospitalet, University of Copenhagen, Copenhagen; ,Department of Orthopedics, Herlev Gentofte Hospital, Copenhagen, Denmark,Correspondence:
| | - Nikolaj Winther
- Department of Orthopedics, Rigshospitalet, University of Copenhagen, Copenhagen;
| | - Thomas Lind
- Department of Orthopedics, Herlev Gentofte Hospital, Copenhagen, Denmark
| | - Henrik M Schrøder
- Department of Orthopedics, Rigshospitalet, University of Copenhagen, Copenhagen;
| | | |
Collapse
|
8
|
Laende EK, Astephen Wilson JL, Mills Flemming J, Valstar ER, Richardson CG, Dunbar MJ. Equivalent 2-year stabilization of uncemented tibial component migration despite higher early migration compared with cemented fixation: an RSA study on 360 total knee arthroplasties. Acta Orthop 2019; 90:172-178. [PMID: 30669909 PMCID: PMC6461081 DOI: 10.1080/17453674.2018.1562633] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Thresholds of implant migration for predicting long-term successful fixation of tibial components in total knee arthroplasty have not separated cemented and uncemented fixation. We compared implant migration of cemented and uncemented components at 1 year and as the change in migration from 1 to 2 years. Patients and methods - Implant migration of 360 tibial components measured using radiostereometric analysis was compared at 1 year and as the change in migration from 1 to 2 years in 222 cemented components (3 implant designs) and 138 uncemented components (5 implant designs). Results - 1-year maximum total point motion was lower for the cemented tibial components compared with the uncemented components (median = 0.31 mm [0.03-2.98] versus 0.63 mm [0.11-5.19] respectively, p < 0.001, mixed model). The change in migration from 1 to 2 years, however, was equivalent for cemented and uncemented components (mean [SD] 0.06 mm [0.19] and 0.07 mm [0.27] mm respectively, p = 0.6, mixed model). Interpretation - These findings suggest that current thresholds of acceptable migration at 1 year may be better optimized by considering cemented and uncemented tibial components separately as higher early migration of uncemented components was not associated with decreased stability from 1 to 2 years.
Collapse
Affiliation(s)
- Elise K Laende
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada;; ,Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada;; ,Correspondence:
| | - Janie L Astephen Wilson
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada;; ,Department of Surgery, Dalhousie University, Halifax, Nova Scotia, Canada;;
| | - Joanna Mills Flemming
- Department of Mathematics and Statistics, Dalhousie University, Halifax, Nova Scotia, Canada;;
| | - Edward R Valstar
- Department of Orthopedics, Leiden University Medical Center, Leiden, The Netherlands
| | - C Glen Richardson
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada;;
| | - Michael J Dunbar
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada;; ,Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada;;
| |
Collapse
|
9
|
Andersen MR, Winther NS, Lind T, Schrøder HM, Mørk Petersen M. Bone Remodeling of the Distal Femur After Uncemented Total Knee Arthroplasty-A 2-Year Prospective DXA Study. J Clin Densitom 2018; 21:236-243. [PMID: 28918227 DOI: 10.1016/j.jocd.2017.05.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2016] [Accepted: 05/06/2017] [Indexed: 11/18/2022]
Abstract
Loss of bone stock as a response to the bone trauma, immobilization, and stress shielding related to joint replacement surgery increases the risk of fracture of the distal femur after total knee arthroplasty. Previous studies of uncemented femoral components have reported very high levels of bone loss in the distal femur. This study investigates the adaptive bone remodeling of the distal femur after uncemented total knee arthroplasty. We performed a 2-year follow-up of 53 patients (mean age 61.5 [38-70] years, F/M = 27/26, body mass index 29.5) who because of osteoarthritis received an uncemented total knee arthroplasty. All patients received a NexGen CR-Flex Porous Femoral Component. Measurements of bone mineral density of the distal femur using dual-energy X-ray absorptiometry were performed postoperatively and after 3, 6, 12, and 24 months. Bone mineral density (g/cm2) was measured in 3 regions of interest in the periprosthetic bone of the distal femur. Repeated measures analysis of variance and Tukey post hoc test for bone mineral density changed over time (p < 0.05 were considered significant). In the distal femur, significant changes in bone mineral density were seen after 24 months of follow-up, and bone mineral density decreased by 23.6% in the anterior region behind the anterior flange of the prosthesis (p < 0.001), 10.1% in the posterior region (p < 0.001), and 5.5% in the most proximal region (p < 0.001). We found highly significant bone mineral change in the distal femur after uncemented total knee arthroplasty, most pronounced in the anterior region, where a decrease in bone mineral density of almost 25%, was seen. Taking the expected age-related decay in bone mineral density in this age group into consideration, the decrease was substantial and must be considered to predispose to periprosthetic fractures.
Collapse
Affiliation(s)
- Mikkel Rathsach Andersen
- Department of Orthopedics, Rigshospitalet, University of Copenhagen, Denmark; Department of Orthopedics, Herlev Gentofte Hospital, University of Copenhagen, Denmark.
| | - Nikolaj S Winther
- Department of Orthopedics, Rigshospitalet, University of Copenhagen, Denmark
| | - Thomas Lind
- Department of Orthopedics, Herlev Gentofte Hospital, University of Copenhagen, Denmark
| | - Henrik M Schrøder
- Department of Orthopedics, Rigshospitalet, University of Copenhagen, Denmark
| | | |
Collapse
|