1
|
Ngo D, Todd M, Accadbled F, Foster B, Jellesen MS, Rölfing JD, Rawat J. Corrosion of a Fassier-Duval Telescopic Nail Causing Pain and Osteolysis: A Case Report. JBJS Case Connect 2024; 14:01709767-202403000-00003. [PMID: 38181104 DOI: 10.2106/jbjs.cc.23.00424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2024]
Abstract
CASE A 15-year-old girl known with osteogenesis imperfecta presented with left femoral pain. She had been treated with multiple Fassier-Duval intramedullary nails, which were still in situ. Radiographic imaging demonstrated focal osteolysis and periosteal reaction at the telescopic junction of the rod in the distal femur. She underwent implant removal. Intraoperative sampling demonstrating acute sterile inflammation and presence of brownish colored particles consistent with metal debris and osteolysis. Explant analysis confirmed corrosion of the stainless-steel telescopic nail as the underlying cause. CONCLUSION Osteolysis and periosteal reaction because of corrosion should be considered in conjunction with other more common causes of pain, such as fracture or infection, in patients treated with telescopic intramedullary nails.
Collapse
Affiliation(s)
- David Ngo
- Flinders Medical Centre, Bedford Park, Australia
| | - Maya Todd
- Flinders Medical Centre, Bedford Park, Australia
| | | | - Bruce Foster
- Flinders Medical Centre, Bedford Park, Australia
| | - Morten Stendahl Jellesen
- Department of Civil and Mechanical Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Jan Duedal Rölfing
- Children's Orthopaedics and Reconstruction, Aarhus University Hospital, Aarhus, Denmark
| | | |
Collapse
|
2
|
Geiger EJ, Geffner AD, Rozbruch SR, Fragomen AT. Management of Segmental Tibial Bone Defects With the Magnetic Motorized Intramedullary Transport Nail: A Case Series. J Orthop Trauma 2023; 37:e459-e465. [PMID: 36750433 DOI: 10.1097/bot.0000000000002574] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/17/2023] [Indexed: 02/09/2023]
Abstract
SUMMARY Critical-sized bone defects in the tibia can arise as sequelae of trauma, infection, tumor, or the treatment of congenital limb deficiencies. Treatment of these defects often requires bone transport, which has traditionally been accomplished using circular external fixators. The development of a bone transport nail facilitated tibia reconstruction through distraction osteogenesis using an all-internal device, thus avoiding the complications associated with chronic external fixation. Given the rarity of these cases, few studies have been published on the reconstruction outcomes using this implant. We sought to investigate the bone healing indices (including regenerate consolidation and time to docking site union) associated with the use of a magnetically controlled all-internal bone transport nail for the reconstruction of 4 patients treated for posttraumatic tibial bone loss. Perioperative and device-related complications are also reported.
Collapse
Affiliation(s)
- Erik J Geiger
- The Rothman Institute and the Department of Orthopedic Surgery, Thomas Jefferson University, Philadelphia, PA; and
| | - Adam D Geffner
- Department of Limb Lengthening and Complex Reconstruction, Hospital for Special Surgery, New York, NY
| | - S Robert Rozbruch
- Department of Limb Lengthening and Complex Reconstruction, Hospital for Special Surgery, New York, NY
| | - Austin T Fragomen
- Department of Limb Lengthening and Complex Reconstruction, Hospital for Special Surgery, New York, NY
| |
Collapse
|
3
|
Olesen UK, Herzenberg JE, Hindsø K, Singh UM, Petersen MM. Plate-assisted bone-segment transport in the femur with 2 internal lengthening nails: a technical note and a case report. Acta Orthop 2023; 94:466-470. [PMID: 37712251 PMCID: PMC10506739 DOI: 10.2340/17453674.2023.18493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Accepted: 08/07/2023] [Indexed: 09/16/2023] Open
Abstract
A novel technique to resolve large bone defects, using 2 internal lengthening nails (ILNs), one antegrade and one retro-grade, aligned in a custom-made tube is presented. A 28-year-old, healthy, asymptomatic male presented with a slowly growing mass in the left femur.
Collapse
Affiliation(s)
- Ulrik Kähler Olesen
- Department of Orthopedic Surgery, Limb Reconstruction, Rigshospitalet, Copenhagen, Denmark.
| | | | - Klaus Hindsø
- Department of Orthopedic Surgery, Limb Reconstruction, Rigshospitalet, Copenhagen, Denmark
| | - Upender Martin Singh
- Department of Orthopedic Surgery, Limb Reconstruction, Rigshospitalet, Copenhagen, Denmark
| | - Michael Mørk Petersen
- Department of Orthopedic Surgery, Limb Reconstruction, Rigshospitalet, Copenhagen, Denmark
| |
Collapse
|
4
|
Reif TJ, Geffner A, Hoellwarth JS, Fragomen AT, Rozbruch SR. Precice Stryde® Magnetic Internal Lengthening Nail does not Impair Bone Healing Despite Radiographic and Clinical Symptoms. Strategies Trauma Limb Reconstr 2023; 18:94-99. [PMID: 37942435 PMCID: PMC10628610 DOI: 10.5005/jp-journals-10080-1514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Accepted: 03/11/2023] [Indexed: 11/10/2023] Open
Abstract
Aims The Precice Stryde® internal magnetic lengthening nail allowed many patients a full weight-bearing experience during femur and tibia lengthening, but concerns over corrosion, pain and radiographic changes led to the implant's recall. Despite the recall, it is important to understand the rate of these occurrences and their influence on the overall success of the lengthening procedure. We aimed to investigate radiographic changes, patient-reported symptoms and bone healing indices for our cohort of Stryde lengthening. Materials and methods Our surgical database and electronic medical record system were used to review and document patient demographics, indications for lengthening, length achieved, bone healing index (BHI), location and type of radiographic changes, time until radiographic changes were first visible, presence of pain symptoms (not attributable to surgery or distraction), time to implant removal and if the pain symptoms resolved following implant extraction. Results From January 2019 to February 2021, 90 Stryde nails (78 femur and 12 tibia) were implanted in 63 patients. The cohort included 48 males and 15 females. The average length [± standard deviation (SD)] achieved was 58.4 ± 22.7 mm. The 66 bones (73%) developed radiographic changes and were found to be 58/78 (74%) femurs and 8/12 (67%) tibias. The average time to initial radiographic changes was 168 ± 108.1 days (femur) and 276 ± 126.8 days (tibia). Late-onset pain developed in 10 femur lengthening (11.1% of all nails) surgeries across eight patients (12.7% of all patients). All patients' pain resolved; three instances prior to nail removal and the remaining seven after nail removal. No patients were re-presented with worsening pain or radiographic changes following implant removal. Radiographic or symptomatic abnormalities did not impair bone formation. The BHI for femurs with (29.6 ± 16.6 days/cm, n = 58) vs without (29.4 ± 17.9 days/cm, n = 20) radiographic or symptomatic irregularity were nearly identical (p = 0.961). The difference between BHI for tibias with (39.3 ± 7.8 days/cm, n = 8) vs without (86.1 ± 38.2 days/cm, n = 4) radiographic changes was influenced by outliers and underpowered to draw a conclusion. Conclusion Bone lengthening with the Stryde nail was associated with high rates of radiographic abnormalities, but symptoms were uncommon and resolved with explantation. The radiographic changes did not affect bone healing in the femur. Clinical significance Radiographic changes including bone hypertrophy and osteolysis were common after bone lengthening with the Stryde nail, but the development of pain following consolidation was rare and resolved with implant removal.The BHI in femurs was not affected by radiographic changes. How to cite this article Reif TJ, Geffner A, Hoellwarth JS, et al. Precice Stryde® Magnetic Internal Lengthening Nail does not Impair Bone Healing Despite Radiographic and Clinical Symptoms. Strategies Trauma Limb Reconstr 2023;18(2):94-99.
Collapse
Affiliation(s)
- Taylor J Reif
- Department of Limb Lengthening and Complex Reconstruction, Hospital for Special Surgery, New York, United States of America
| | - Adam Geffner
- Department of Limb Lengthening and Complex Reconstruction, Hospital for Special Surgery, New York, United States of America
| | - Jason S Hoellwarth
- Department of Limb Lengthening and Complex Reconstruction, Hospital for Special Surgery, New York, United States of America
| | - Austin T Fragomen
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, United States of America
| | - S Robert Rozbruch
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, United States of America
| |
Collapse
|
5
|
Hafez M, Nicolaou N, Offiah A, Obasohan P, Dixon S, Giles S, Madan S, Fernandes JA. How Much Does Paediatric Femoral Lengthening Cost? A Cost Comparison between Magnetic Lengthening Nails and External Fixators. Strategies Trauma Limb Reconstr 2023; 18:16-20. [PMID: 38033930 PMCID: PMC10682557 DOI: 10.5005/jp-journals-10080-1573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Accepted: 01/23/2023] [Indexed: 12/02/2023] Open
Abstract
Aim Motorised intramedullary lengthening nails are considered more expensive than external fixators for limb lengthening. This research aims to compare the cost of femoral lengthening in children using the PRECICE magnetic lengthening nail with external fixation. Methods Retrospective analysis of 50 children who underwent femoral lengthening. One group included patients who were treated with PRECICE lengthening nails, the other group included patients who had lengthening with external fixation. Each group included 25 patients aged between 11 and 17 years. The patients in both groups were matched for age. Cost analysis was performed following micro-costing and analysis of the used resources during the different phases of the treatments. Results Each group's mean patient age was 14.7 years. Lengthening nails were associated with longer operative times compared with external fixators, both for implantation and removal surgery (p-values of 0.007 and < 0.0001, respectively). Length of stay following the implantation surgery, frequency of radiographs and frequency of outpatient department appointments were all lower with lengthening nails. The overall cost of lengthening nails was £1393 more than external fixators, however, this difference was not statistically significant (p-value = 0.088). Conclusion The difference in the mean costs between femoral lengthening with lengthening nails versus external fixators was not statistically significant. Further research to review the effectiveness of the devices and the quality of life during the lengthening process is crucial for robust health economic evaluation. How to cite this article Hafez M, Nicolaou N, Offiah A, et al. How Much Does Paediatric Femoral Lengthening Cost? A Cost Comparison between Magnetic Lengthening Nails and External Fixators. Strategies Trauma Limb Reconstr 2023;18(1):16-20.
Collapse
Affiliation(s)
- Mohamed Hafez
- Department of Paediatric Trauma and Orthopaedic, Sheffield Children's Hospital, Sheffield, England, United Kingdom
| | - Nicolas Nicolaou
- Department of Paediatric Trauma and Orthopaedic, Sheffield Children's Hospital, Sheffield, England, United Kingdom
| | - Amaka Offiah
- Department of Oncology and Metabolism, University of Sheffield, Sheffield, United Kingdom
| | - Phillips Obasohan
- Department of Medical Statistics, School of Health and Related Research, University of Sheffield, Sheffield, United Kingdom
| | - Simon Dixon
- Department of Health Economics and Decision Science, School of Health and Related Research, Sheffield, United Kingdom
| | - Stephen Giles
- Department of Trauma and Orthopaedics, Sheffield Children's Hospital, Sheffield, England, United Kingdom
| | - Sanjeev Madan
- Department of Paediatric Limb Reconstruction, Sheffield Children's Hospital NHS Trust, Sheffield, England, United Kingdom
| | - James Alfred Fernandes
- Department of Trauma and Orthopaedics, Sheffield Children's Hospital, Sheffield, England, United Kingdom
| |
Collapse
|
6
|
Vogt B, Rupp C, Gosheger G, Eveslage M, Laufer A, Toporowski G, Roedl R, Frommer A. A clinical and radiological matched-pair analysis of patients treated with the PRECICE and STRYDE magnetically driven motorized intramedullary lengthening nails. Bone Joint J 2023; 105-B:88-96. [PMID: 36587248 DOI: 10.1302/0301-620x.105b1.bjj-2022-0755.r1] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
AIMS Distraction osteogenesis with intramedullary lengthening devices has undergone rapid development in the past decade with implant enhancement. In this first single-centre matched-pair analysis we focus on the comparison of treatment with the PRECICE and STRYDE intramedullary lengthening devices and aim to clarify any clinical and radiological differences. METHODS A single-centre 2:1 matched-pair retrospective analysis of 42 patients treated with the STRYDE and 82 patients treated with the PRECICE nail between May 2013 and November 2020 was conducted. Clinical and lengthening parameters were compared while focusing radiological assessment on osseous alterations related to the nail's telescopic junction and locking bolts at four different stages. RESULTS Osteolysis next to the telescopic junction was observed in 31/48 segments (65%) lengthened with the STRYDE nail before implant removal compared to 1/91 segment (1%) in the PRECICE cohort. In the STRYDE cohort, osteolysis initially increased, but decreased or resolved in almost all lengthened segments (86%) after implant removal. Implant failure was observed in 9/48 STRYDE (19%) and in 8/92 PRECICE nails (9%). Breakage of the distal locking bolts was found in 5/48 STRYDE nails (10%) compared to none in the PRECICE cohort. Treatment-associated pain was generally recorded as mild and found in 30/48 patients (63%) and 39/92 (42%) in the STRYDE and PRECICE cohorts, respectively. Temporary range of motion (ROM) limitations under distraction were registered in 17/48 (35%) segments treated with the STRYDE and 35/92 segments (38%) treated with the PRECICE nail. CONCLUSION Osteolysis and periosteal reaction, implant breakage, and pain during lengthening and consolidation is more likely in patients treated with the STRYDE nail compared to the PRECICE nail. Temporary ROM limitations during lengthening occurred independent of the applied device. Implant-related osseous alterations seem to remodel after implant removal.Cite this article: Bone Joint J 2023;105-B(1):88-96.
Collapse
Affiliation(s)
- Bjoern Vogt
- Paediatric Orthopaedics, Deformity Reconstruction, and Foot Surgery, Münster University Hospital, Münster, Germany
| | - Carolin Rupp
- Paediatric Orthopaedics, Deformity Reconstruction, and Foot Surgery, Münster University Hospital, Münster, Germany
| | - Georg Gosheger
- General Orthopaedics and Tumour Orthopaedics, Münster University Hospital, Münster, Germany
| | - Maria Eveslage
- Institute of Biostatistics and Clinical Research, University of Münster, Münster, Germany
| | - Andrea Laufer
- Paediatric Orthopaedics, Deformity Reconstruction, and Foot Surgery, Münster University Hospital, Münster, Germany.,General Orthopaedics and Tumour Orthopaedics, Münster University Hospital, Münster, Germany
| | - Gregor Toporowski
- Paediatric Orthopaedics, Deformity Reconstruction, and Foot Surgery, Münster University Hospital, Münster, Germany.,General Orthopaedics and Tumour Orthopaedics, Münster University Hospital, Münster, Germany
| | - Robert Roedl
- Paediatric Orthopaedics, Deformity Reconstruction, and Foot Surgery, Münster University Hospital, Münster, Germany
| | - Adrien Frommer
- Paediatric Orthopaedics, Deformity Reconstruction, and Foot Surgery, Münster University Hospital, Münster, Germany.,General Orthopaedics and Tumour Orthopaedics, Münster University Hospital, Münster, Germany
| |
Collapse
|
7
|
Mittal A, Allahabadi S, Jayaram R, Nalluri A, Callahan M, Sabharwal S. Trends and Practices in Limb Lengthening: An 11-year US Database Study. Strategies Trauma Limb Reconstr 2023; 18:21-31. [PMID: 38033925 PMCID: PMC10682549 DOI: 10.5005/jp-journals-10080-1574] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Accepted: 03/11/2023] [Indexed: 12/02/2023] Open
Abstract
Aim Over the past couple of decades, limb lengthening has evolved to encompass various implants and techniques. The purpose of this study was to (1) determine trends in the utilisation of various limb lengthening techniques for the femur and tibia in the United States, (2) determine trends in 1-year readmission rate following limb lengthening procedures and (3) to study the relationship of limb lengthening implant used and payment method used with the underlying diagnosis associated with limb shortening. Materials and methods Inpatient data were acquired using the Healthcare Cost and Utilisation Project (HCUP) database from 2005 to 2015 from seven states in the United States. Patients with an International Classification of Diseases (ICD)-9 code for limb lengthening of the femur or tibia were included. A total of 2,563 patients were included. Data were analysed using descriptive statistics, and chi-square test was used for comparison of subcategories. Linear regression analysis was used to examine trends over time. Results There was a strong linear trend towards increasing proportional use of internal lengthening of the femur from 2011 to 2015 (R2 = 0.99) with an increase of 10.2% per year. A similar trend towards increasing proportional use of internal lengthening of the tibia was seen from 2011 to 2015 (R2 = 0.87) with an increase of 4.9% per year. There was a moderate correlation showing a decrease in readmission rate of 1.07% per year from 2005 to 2015 (R2 = 0.55). Patients with short stature had increased use of internal lengthening and self-payment compared to patients with congenital, post-traumatic or other diagnoses. Conclusion There was increasing use of internal lengthening techniques from 2011 to 2015. Patients with short stature had higher use of internal lengthening technique and self-pay for payment method. Clinical significance Intramedullary devices have seen increasing use for limb lengthening procedures. Lengthening technique and payment method may differ by underlying diagnosis. How to cite this article Mittal A, Allahabadi S, Jayaram R, et al. Trends and Practices in Limb Lengthening: An 11-year US Database Study. Strategies Trauma Limb Reconstr 2023;18(1):21-31.
Collapse
Affiliation(s)
- Ashish Mittal
- Department of Orthopedic Surgery, St. Mary's Medical Center, San Francisco, California, United States of America
| | - Sachin Allahabadi
- Department of Orthopedic Surgery, University of California, San Francisco, California, United States of America
| | - Rishab Jayaram
- Department of Orthopedic Surgery, University of Rochester, Rochester, New York, United States of America
| | - Abhinav Nalluri
- Department of Orthopedic Surgery, St. Mary's Medical Center, San Francisco, California, United States of America
| | - Matt Callahan
- Department of Orthopedic Surgery, University of California, San Francisco, California, United States of America
| | - Sanjeev Sabharwal
- Department of Orthopedic Surgery, University of California, San Francisco; UCSF Benioff Children's Hospital, Oakland, California, United States of America
| |
Collapse
|
8
|
No osteolysis at the telescopic junction of 128 FITBONE lengthening nails. Orthop Traumatol Surg Res 2022; 109:103501. [PMID: 36470369 DOI: 10.1016/j.otsr.2022.103501] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Revised: 11/06/2022] [Accepted: 11/15/2022] [Indexed: 12/10/2022]
Abstract
BACKGROUND Motorized lengthening nails are the treatment standard for bone lengthening of the lower limbs. However, bony changes namely osteolysis and periosteal hypertrophy have been described after certain type of magnetically driven lengthening nails. The aim of this study was to estimate the proportion rate of radiological bone abnormalities of Fitbone TAA femoral or tibial lengthening nails with a minimum follow-up time of 1 year. HYPOTHESIS The bone surrounding the telescopic junction of Fitbone lengthening nails does not exhibit osteolysis or periosteal reactions. The bone surrounding the locking screws exhibits cortical hypertrophy. PATIENTS AND METHODS Single-centre retrospective case series of patients treated with a Fitbone nails with a minimum follow-up of 1 year after implantation. Standard orthogonal radiographs were obtained postoperatively, weekly during the distraction phase, and then monthly for 6 months, and before removal of the equipment. We looked for bone abnormalities at the telescoping junction of the nail and at the locking screws before removal. RESULTS In total, 101 patients (58 males, 43 females) with a mean age of 21 years (range: 11.8-53.5) had 128 (101 femoral and 27 tibial) limb lengthening nails implanted between 2010 and 2021. The mean follow-up period was 925 days (range: 371-3587). The mean lengthening was 4.7cm (range: 1.5-8.0). No bones exhibited focal osteolysis or periosteal reactions at the telescopic junction of the lengthening nail. Cortical hypertrophy at the locking screws was observed in significantly more Fitbone nails than previously reported, i.e., 101/128 (79%). DISCUSSION Neither focal osteolysis, nor periosteal reactions were observed at the bone surrounding the telescopic junction of 128 Fitbone lengthening nails. Cortical hypertrophy around the single diaphyseal locking screw was observed in 101/128 (79%) of the cases. These absences of osteolytic changes after long term observation are reassuring for both surgeons and patients alike. LEVEL OF EVIDENCE IV.
Collapse
|
9
|
Vogt B, Rölfing JD, Roedl R, Frommer A. Letter to the editor on "STRYDE versus PRECICE magnetic internal lengthening nail for femur lengthening". Arch Orthop Trauma Surg 2022; 142:3563-3564. [PMID: 34292381 DOI: 10.1007/s00402-021-04074-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Accepted: 07/13/2021] [Indexed: 10/20/2022]
Affiliation(s)
- Björn Vogt
- Department of Children's Orthopaedics, Deformity Reconstruction and Foot Surgery, University Hospital of Muenster, Albert-Schweitzer-Campus 1, 48149, Muenster, Germany.
| | - Jan Duedal Rölfing
- Department of Children's Orthopaedics, Deformity Reconstruction and Foot Surgery, University Hospital of Muenster, Albert-Schweitzer-Campus 1, 48149, Muenster, Germany
- Children's Orthopaedics and Reconstruction, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark
| | - Robert Roedl
- Department of Children's Orthopaedics, Deformity Reconstruction and Foot Surgery, University Hospital of Muenster, Albert-Schweitzer-Campus 1, 48149, Muenster, Germany
| | - Adrien Frommer
- Department of Children's Orthopaedics, Deformity Reconstruction and Foot Surgery, University Hospital of Muenster, Albert-Schweitzer-Campus 1, 48149, Muenster, Germany
| |
Collapse
|
10
|
Calder PR, Wright J, Goodier WD. An Update on the Intramedullary Implant in Limb Lengthening: A Quinquennial Review Part 2: Extending Surgical Indications and Further Innovation. Injury 2022; 53 Suppl 3:S88-S94. [PMID: 35851475 DOI: 10.1016/j.injury.2022.06.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 06/17/2022] [Accepted: 06/19/2022] [Indexed: 02/02/2023]
Abstract
The use of the intramedullary lengthening nail has gained in popularity over the last decade. The reduction in complications associated with the use of external fixators and excellent patient outcomes has resulted in the largest change in management of limb length discrepancy since the concept of distraction osteogenesis was accepted by the Western world in the 1980s. Success following "simple" limb lengthening has led to surgeons extending the indications for the lengthening nail, including different bone segments, lengthening associated with potential joint instability and lengthening combined with acute deformity correction. There has been a drive for further implant modification to reduce complications, and enable full weight bearing during the lengthening process. This would offer the opportunity to consider simultaneous limb lengthening. The aim of this review is to evaluate the literature published over the last five years and highlight important learning points and technical tips for these expanding indications.
Collapse
Affiliation(s)
- Peter R Calder
- The Royal National Orthopaedic Hospital, Stanmore, Middlesex, HA7 4LP, United Kingdom.
| | - Jonathan Wright
- The Royal National Orthopaedic Hospital, Stanmore, Middlesex, HA7 4LP, United Kingdom
| | - W David Goodier
- The Royal National Orthopaedic Hospital, Stanmore, Middlesex, HA7 4LP, United Kingdom
| |
Collapse
|
11
|
RADLER C, MINDLER GT, STAUFFER A, WEIß C, GANGER R. Correction of post-traumatic lower-limb discrepancy with Precice intramedullary lengthening nails: a review of 34 adults with an average follow-up of 2 years. Acta Orthop 2022; 93:696-702. [PMID: 36069481 PMCID: PMC9450255 DOI: 10.2340/17453674.2022.4513] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE We report results and complications of gradual bone lengthening for post-traumatic lower-limb length discrepancy (LLD) with Precice intramedullary lengthening nails in 34 adults. PATIENTS AND METHODS Inclusion criteria were lower-limb lengthening using the Precice nail, posttraumatic etiology, age older than 18 years, and minimum follow-up of 12 months after implantation. 34 patients met the inclusion criteria. Radiological and clinical outcome data were collected. RESULTS Precice lengthening was performed in the femur in 28 patients (21 antegrade, 7 retrograde) and in the tibia in 6. Mean patient age at time of surgery was 32 years (18-72). Mean preoperative LLD was 31 mm (20-71). Acute correction of axial or rotational malalignment was performed in 11 segments. At final follow-up (mean 2 years [1.1-3.6]), 33 of 34 nails had been removed. All lengthening sites were healed, and all patients mobilized with full weight-bearing. 14 adverse events occurred in 11 patients and were categorized as problems (n = 5), obstacles (n = 3), and complications (n = 6). Unplanned surgery was necessary in 7 patients, 3 of whom did not complete treatment with Precice. INTERPRETATION Correction of posttraumatic LLD with or without axial malalignment using Precice intramedullary lengthening nails is associated with a low number of complications and good functional outcome. However, one-fifth of patients in this series needed further unplanned surgery for revision of obstacles or complications.
Collapse
Affiliation(s)
- Christof RADLER
- Department of Pediatric Orthopaedics, Orthopaedic Hospital Speising, Vienna, Austria
| | - Gabriel T MINDLER
- Department of Pediatric Orthopaedics, Orthopaedic Hospital Speising, Vienna, Austria
| | - Alexandra STAUFFER
- Department of Pediatric Orthopaedics, Orthopaedic Hospital Speising, Vienna, Austria
| | - Carina WEIß
- Department of Pediatric Orthopaedics, Orthopaedic Hospital Speising, Vienna, Austria
| | - Rudolf GANGER
- Department of Pediatric Orthopaedics, Orthopaedic Hospital Speising, Vienna, Austria
| |
Collapse
|
12
|
Bafor A, Iobst CA. What's New in Limb Lengthening and Deformity Correction. J Bone Joint Surg Am 2022; 104:1419-1425. [PMID: 35703147 DOI: 10.2106/jbjs.22.00398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Affiliation(s)
- Anirejuoritse Bafor
- Department of Orthopedic Surgery, Nationwide Children's Hospital, Columbus, Ohio
| | | |
Collapse
|
13
|
Does Focal Osteolysis in a PRECICE Stryde Intramedullary Lengthening Nail Resolve after Explantation? CHILDREN 2022; 9:children9060860. [PMID: 35740797 PMCID: PMC9221827 DOI: 10.3390/children9060860] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 06/01/2022] [Accepted: 06/05/2022] [Indexed: 11/30/2022]
Abstract
Concerns surrounding osteolysis near and around the modular junction of a stainless-steel intramedullary lengthening rod prompted a manufacturer recall from the United States market in early 2021. These actions were preceded by similar steps taken in Europe. A concomitant review of stainless-steel lengthenings at our institution demonstrated signs of adverse tissue reaction including periosteal reaction and osteolysis at the modular junction and/or male-sided locking screws. Nearly half of our patients presented with these findings on radiographic images. At the time of the previous review, only half of the nearly 60 implanted stainless-steel devices met a 6-month follow-up. At this juncture, many patients have had their devices explanted. Given the suspected adverse tissue reactions caused by a component of the internal device, we sought to examine the rate of osteolysis post-explantation following removal of a stainless-steel nail. We reviewed a consecutive series of patients who underwent implantation of a stainless-steel limb lengthening device in the femur and/or tibia at a single institution between December 2018 and December 2020. Patients were included if their device was explanted. Periosteal reaction and osteolysis was classified according to a novel and validated classification system, as analyzed by five fellowship-trained surgeons. In addition, changes observed prior to explantation were tracked post-explantation to assess for resolution. The incidence of periosteal reaction and osteolysis prior to explantation was 22/57 (39%) and 15/57 (26%), respectively. Of the 15 patients with osteolysis pre-explantation, 14 patients’ implants were explanted. Of these, eight patients had available follow-up films. Two patients were identified as having partial osteolysis resolution at mean 1-year follow-up, while six patients were identified as having complete osteolysis at mean 18-months follow-up. Periosteal tissue reaction and osteolysis largely resolved following explantation in a subset of patients. These results provide further support to the claim that the stainless-steel device contributed to the changes seen. Further follow-up is warranted to examine the longer-term effects of adverse tissue reaction in this patient population.
Collapse
|
14
|
Hafez M, Nicolaou N, Offiah A, Offorha B, Giles S, Madan S, Fernandes JA. Quality of life of children during distraction osteogenesis: a comparison between intramedullary magnetic lengthening nails and external fixators. INTERNATIONAL ORTHOPAEDICS 2022; 46:1367-1373. [PMID: 35385976 PMCID: PMC9117380 DOI: 10.1007/s00264-022-05399-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/22/2022] [Accepted: 03/31/2022] [Indexed: 12/01/2022]
Abstract
Background Distraction osteogenesis is a very demanding process. For decades, external fixation was the only reliable option for gradual deformity correction. Recently, intramedullary magnetic nails have gained popularity. This research aimed to assess the quality of life in children during gradual deformity correction using intramedullary lengthening nails compared to external fixation. Method Prospective analysis included children who had gradual lower limb deformity correction between 2017 and 2019. Group A included children who had magnetic lengthening nails; patients in group B had external fixation devices. Child health utility 9D (CHU- 9D) and EuroQol 5D youth (EQ- 5D-Y) were used to measure the quality of life at fixed points during the distraction osteogenesis process. The results were used to calculate the utility at each milestone and the overall quality of life adjusted years (QALYs). Results Thirty-four children were recruited, group A had 16 patients, whilst group B had 18 patients. The average ages were 16.0 years and 14.7 years for groups A and B, respectively. Group A patients reported significantly better utility compared to group B. This was observed during all stages of treatment (P = 0.00016). QALYs were better for group A (0.44) compared to group B (0.34) (P < 0.0001). Conclusion The quality of life was generally better in group A compared to group B. In most patients, the health utility progressively improved throughout treatment. In the same way, QALYs were better with the lengthening nails compared to external fixators. The magnetic lengthening devices (PRECICE nails) which were used in this research were recently relabelled to restrict their applications in children; this study was conducted before these restrictions.
Collapse
Affiliation(s)
- Mohamed Hafez
- Paediatric Limb Reconstruction Unit, Sheffield Children's Hospital, Western Bank, Sheffield, S10 2TH, UK. .,Oncology and Metabolism Department, Medical School, Sheffield University, Sheffield, UK.
| | - Nicolas Nicolaou
- Paediatric Limb Reconstruction Unit, Sheffield Children's Hospital, Western Bank, Sheffield, S10 2TH, UK.,Sheffield University, Sheffield, UK
| | - Amaka Offiah
- Oncology and Metabolism Department, Medical School, Sheffield University, Sheffield, UK
| | - Bright Offorha
- School of Health and Related Research, Sheffield University, Sheffield, UK
| | - Stephen Giles
- Paediatric Limb Reconstruction Unit, Sheffield Children's Hospital, Western Bank, Sheffield, S10 2TH, UK.,Sheffield University, Sheffield, UK
| | - Sanjeev Madan
- Paediatric Limb Reconstruction Unit, Sheffield Children's Hospital, Western Bank, Sheffield, S10 2TH, UK.,Sheffield University, Sheffield, UK
| | - James A Fernandes
- Paediatric Limb Reconstruction Unit, Sheffield Children's Hospital, Western Bank, Sheffield, S10 2TH, UK.,Sheffield University, Sheffield, UK
| |
Collapse
|
15
|
Sabharwal S. CORR Insights®: What Are the Potential Benefits and Risks of Using Magnetically Driven Antegrade Intramedullary Lengthening Nails for Femoral Lengthening to Treat Leg Length Discrepancy? Clin Orthop Relat Res 2022; 480:804-806. [PMID: 34851860 PMCID: PMC8923588 DOI: 10.1097/corr.0000000000002079] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Accepted: 11/09/2021] [Indexed: 01/31/2023]
Affiliation(s)
- Sanjeev Sabharwal
- Professor, University of California, San Francisco (UCSF), Benioff Children's Hospital Oakland, Oakland, CA, USA
| |
Collapse
|
16
|
The Clinical History and Basic Science Origins of Transcutaneous Osseointegration for Amputees. Adv Orthop 2022; 2022:7960559. [PMID: 35340813 PMCID: PMC8956382 DOI: 10.1155/2022/7960559] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 02/23/2022] [Accepted: 03/02/2022] [Indexed: 11/24/2022] Open
Abstract
Transcutaneous osseointegration for amputees (TOFA) refers to an intramedullary metal endoprosthesis which passes transcutaneously to connect with a limb exoprosthesis. The first recognizably modern experiments and attempts occurred in the 1940s. Multiple researchers using a plethora of materials and techniques over the following 50 years identified principles and obstacles which informed the first long-term successful surgery in 1990. Unfortunately, the current mainstream TOFA literature presents almost exclusively subsequent developments, generally omitting prior research, leading to some historical mistakes being repeated. Given the increasing interest and surgical volume of TOFA, this literature review was performed to delineate TOFA's basic science and surgical origins and to integrate these early efforts within the contemporary understanding. Studying this research could protect and benefit future patients, surgeons, and implant developers as TOFA is entering a phase of increased attention and innovation. The aim of this article is to provide a focused reference of foundational research, much of which is difficult to identify and retrieve, for clinicians and researchers.
Collapse
|
17
|
Hafez M, Nicolaou N, Offiah A, Giles SN, Madan SS, Fernandes JA. Femoral Lengthening in Children-A Comparison Between Magnetic Intramedullary Lengthening Nails and External Fixators. J Pediatr Orthop 2022; 42:e290-e294. [PMID: 34967804 DOI: 10.1097/bpo.0000000000002039] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Femoral lengthening can be achieved using external fixators or intramedullary lengthening nails. The purpose of this research was to compare the outcome of femoral lengthening in children using PRECICE magnetic lengthening nails with lengthening external fixators. METHODS Retrospective analysis of 50 children who had femoral lengthening. Group A included patients who had lengthening with external fixation, patients in Group B had lengthening with PRECICE intramedullary lengthening nails. Each group included 25 patients. The sample strictly included children aged between 11 and 17 years. Patients in each group were matched according to age and indication for lengthening whether congenital or acquired conditions. The outcomes focused on the ability to achieve target length, healing index, residual malalignment, length of hospitalization following the osteotomy surgery, and encountered complications. RESULTS Mean patient age was 14.7 years for each group. The length gain was 42±12 mm for Group A and 41.6±8 mm for Group B (P=0.84). Lengthening nails achieved the target length more accurately compared with external fixation (P=0.017). The healing index was significantly higher in group A with 53.2±19 days/cm compared with 40.2±14 days/cm in group B (P=0.03). Group A had significantly higher complications than group B (P<0.0001). There was no statistically significant difference in the final coronal malalignment between the 2 groups (P=0.2). The mean length of stay was 9.2±5.8 days for group A and 4.2±3.3 days for group B (P=0.0005). CONCLUSION Magnetic lengthening nails are clinically effective for femoral lengthening in the pediatric population. Compared with external fixation, healing index and complications were more favorable with PRECICE nails. Further research is required to study the cost-effectiveness of this technique. LEVEL OF EVIDENCE Level IV-case series.
Collapse
Affiliation(s)
- Mohamed Hafez
- Department of Oncology and Metabolism, Medical School, Sheffield University
- Paediatric Limb Reconstruction Unit
| | - Nicolas Nicolaou
- Department of Oncology and Metabolism, Medical School, Sheffield University
- Paediatric Limb Reconstruction Unit
| | - Amaka Offiah
- Department of Oncology and Metabolism, Medical School, Sheffield University
- Radiology Department, Sheffield Children's Hospital, Sheffield, UK
| | - Stephen N Giles
- Department of Oncology and Metabolism, Medical School, Sheffield University
- Paediatric Limb Reconstruction Unit
| | - Sanjeev S Madan
- Department of Oncology and Metabolism, Medical School, Sheffield University
- Paediatric Limb Reconstruction Unit
| | - James A Fernandes
- Department of Oncology and Metabolism, Medical School, Sheffield University
- Paediatric Limb Reconstruction Unit
| |
Collapse
|
18
|
Can a humid storage environment of surgical instruments before reprocessing increase patient safety and durability of instruments? J Hosp Infect 2022; 122:64-71. [DOI: 10.1016/j.jhin.2022.01.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 11/30/2021] [Accepted: 01/14/2022] [Indexed: 11/20/2022]
|
19
|
Cognetti DJ, Ghali A, Gutierrez-Naranjo BJM, Handcox J, Karia R, Dutta AK. Technical Considerations and Early Results of Magnetic Compressive Intramedullary Nailing for Humeral Shaft Delayed Unions and Nonunions. JSES Int 2022; 6:385-390. [PMID: 35572440 PMCID: PMC9091776 DOI: 10.1016/j.jseint.2021.11.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Background Expandable magnetic rods and intramedullary nails are being used in a number of innovative ways, including limb length discrepancy and scoliosis correction. However, recently, the full complement of these devices has been further explored, with the utilization of their compressive capacity to improve fracture healing. The purpose of the present study was to report on early results of compressive magnetic intramedullary nailing for humeral shaft delayed unions and nonunions. Methods This retrospective case series was completed at a level 1 trauma center, with adult patients who underwent compressive intramedullary nailing from 2017 to 2021 for humeral shaft nonunion or delayed union. The primary indication for this procedure was nonunion in the setting of previous conventional fixation, but a subset of patients with atrophic nonunions and risk factors for recalcitrant nonunion were also included. Results Fourteen patients, with a mean age of 51 ± 17 years, underwent compressive magnetic intramedullary nailing. Nine patients had previously underwent surgery, 6 of which had undergone multiple prior procedures. Five others were initially treated nonoperatively and underwent surgery 4.1 ± 2.9 months out from injury. Ten patients went on to union at a mean of 2.9 ± 2.4 months. One patient experienced hardware failure with nail cut-out at 2 weeks, and one required revision surgery for a wound infection. Three other patients were lost to follow-up, one of which was deceased for reasons unrelated to surgery. Conclusion Compressive magnetic intramedullary nails are a viable solution for complex humeral shaft nonunions, particularly in the setting of previously well-fixed fractures and those at risk of recalcitrant nonunion. However, comparative and prospective studies looking at union rates and secondary procedures are needed to more clearly define their role in treatment and assure their safety, given recent concerns regarding osteolysis at the nail modular junction.
Collapse
|
20
|
Ferreira N, Sabharwal S, Hosny GA, Sharma H, Johari A, Nandalan VP, Vivas M, Parihar M, Nayagam S, Ferguson D, Rölfing JD. Limb reconstruction in a resource-limited environment. SICOT J 2021; 7:66. [PMID: 34981739 PMCID: PMC8725545 DOI: 10.1051/sicotj/2021066] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Accepted: 12/13/2021] [Indexed: 12/13/2022] Open
Abstract
INTRODUCTION Limb salvage and reconstruction are often challenging and even more so in the limited resource setting. The purpose of this narrative review is to explore the strategies for addressing the unique obstacles and opportunities of limb reconstructive surgery in resource-limited environments globally. METHODS We review (1) the global burden and dimension of the problem, (2) the relevance of orthopedic forums and communication, (3) free and open-access software for deformity analysis and correction, (4) bidirectional learning opportunities, and the value of fellowships and mentoring between resource-rich and resource-limited countries, and (5) how societies like SICOT can help to tackle the problem. Finally, case examples are presented to demonstrate the choice of surgical implants, their availability in regions with limited resources, and how the universal principles of limb reconstruction can be applied, irrespective of resource availability. RESULTS Limb reconstruction can often be life-changing surgery with the goals of limb salvage, improved function, and ambulation. The contradiction of relatively few severe limb deformities in high-income countries (HICs) with abundant resources and the considerable burden of limb deformities in resource-limited countries is striking. Free, open access to education and software planning tools are of paramount importance to achieve this goal of limb reconstruction. Bidirectional learning, i.e., knowledge exchange between individual surgeons and societies with limited and abundant resources, can be reached via fellowships and mentoring. The presented cases highlight (1) fixator-assisted wound closure obliviating the need for plastic surgery, (2) open bone transport, and (3) hinged Ilizarov frames for correction of severe deformities. These cases underline that optimal clinical outcome can be achieved with low-cost and readily available implants when the principles of limb reconstruction are skillfully applied. DISCUSSION Limb lengthening and reconstruction are based on universally applicable principles. These have to be applied regardless of the planning tool or surgical implant availability to achieve the goals of limb salvage and improved quality of life.
Collapse
Affiliation(s)
- Nando Ferreira
- Limb Reconstruction, Division of Orthopaedic Surgery, Faculty of Medicine and Health Sciences, Stellenbosch University 7600 Stellenbosch Cape Town South Africa
| | - Sanjeev Sabharwal
- University of California, San Francisco, Limb Lengthening & Reconstruction Center, UCSF Benioff Children’s Hospital Oakland 747 52nd Street, OPC 1st Floor Oakland CA 94609 USA
| | | | - Hemant Sharma
- Hull Limb Reconstruction and Bone Infection Unit, Hull University Teaching Hospitals, University of Hull Hull HU3 2JZ United Kingdom
| | - Ashok Johari
- Paediatric Orthopaedics, B. Nanavati Super Specialty Hospital 400056 Mumbai India
| | - Vasudevan P. Nandalan
- Thangam Institute of Orthopaedic Surgery, Trauma & Ilizarov, Thangam Hospital Palakkad 678004 Kerala India
| | - Mauro Vivas
- Bone reconstruction and lengthening sector, El Cruce High Complexity Hospital 1888 Buenos Aires Argentina
| | - Mangal Parihar
- Center for Limb Lengthening & Reconstruction, Mangal Anand Hospital 400071 Mumbai India
| | - Selvadurai Nayagam
- Royal Liverpool University Hospitals and Royal Liverpool Children’s Hospital L7 8XP Liverpool United Kingdom
| | - David Ferguson
- The James Cook University Hospital TS4 3BW Middlesbrough United Kingdom
| | - Jan Duedal Rölfing
- Children’s Orthopaedics and Reconstruction, Aarhus University Hospital Palle Juul-Jensens Boulevard 99, J801 8200 Aarhus Denmark
| |
Collapse
|
21
|
Abalkhail TB, McClure PK. Removal of a Broken Stainless-Steel Intramedullary Lengthening Stryde Nail: A Case Report and Review of the Literature. JBJS Case Connect 2021; 11:01709767-202112000-00082. [PMID: 34937043 DOI: 10.2106/jbjs.cc.21.00464] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
CASE We report a 15-year-old female patient who underwent femur lengthening with a stainless steel intramedullary lengthening Stryde nail that broke at the end of the lengthening course and required removal. Given the solid noncannulated nature of the nail, this required special strategy to remove broken parts. CONCLUSION Stryde nails are stainless steel lengthening nails that were developed to allow more freedom with weight bearing. Regardless of this change, hardware failure remains possible. In addition to maintaining regenerate integrity, a surgeon must be creative when attempting to remove solid nail types because many techniques for removing failed hardware were developed for cannulated devices.
Collapse
Affiliation(s)
- Talal B Abalkhail
- International Center for Limb Lengthening, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD.,Department of Orthopedics, King Faisal Specialist Hospital & Research Center, Riyadh, Kingdom of Saudi Arabia
| | - Philip K McClure
- International Center for Limb Lengthening, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD
| |
Collapse
|
22
|
Rölfing JD, Bünger M, Petruskevicius J, Abood AA. Removal of broken PRECICE Stryde intramedullary lengthening nails. Orthop Traumatol Surg Res 2021; 107:102958. [PMID: 33965599 DOI: 10.1016/j.otsr.2021.102958] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Revised: 04/11/2021] [Accepted: 04/15/2021] [Indexed: 02/03/2023]
Abstract
This paper describes two different techniques for removal of broken Precice Stryde intramedullary bone lengthening nails, which unlike trauma nails are solid containing mechanical components. Consequently, surgeons face unique challenges when these implants brake within medullary canal. Here, we present our surgical approach for removal of three broken implants. In one patient (46kg) both Ø10mm femoral Stryde implants (max. weight allowance 68kg) broke through the proximal locking screw hole preoperatively on the right side and intraoperatively on the left side (413 and 504 days after index surgery respectively). The third Ø11.5 femoral nail broke through the area containing the magnet (55kg patient, 325 days after index surgery). LEVEL OF EVIDENCE: IV.
Collapse
Affiliation(s)
- Jan Duedal Rölfing
- Children's Orthopaedics and Reconstruction, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus, Denmark; Department of Clinical Medicine, HEALTH, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200 Aarhus, Denmark.
| | - Mathias Bünger
- Children's Orthopaedics and Reconstruction, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus, Denmark
| | - Juozas Petruskevicius
- Children's Orthopaedics and Reconstruction, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus, Denmark
| | - Ahmed A Abood
- Children's Orthopaedics and Reconstruction, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus, Denmark; Department of Clinical Medicine, HEALTH, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200 Aarhus, Denmark
| |
Collapse
|
23
|
Patterson JT. Plate-Tensioned-Nail for Salvage of Failed Subtrochanteric Intramedullary Motorized Limb Lengthening: A Case Report. JBJS Case Connect 2021; 11:01709767-202112000-00050. [PMID: 34762607 DOI: 10.2106/jbjs.cc.21.00434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
CASE A 43-year-old insulin-dependent man with a 4.4-cm posttraumatic femoral limb length discrepancy sustained a subtrochanteric femur fracture associated with failure of a motorized intramedullary limb lengthening nail during distraction osteogenesis. The patient requested a single-stage salvage operation. After implant removal, the femur was stabilized and compressed with a plate-tensioned-nail construct consisting of 4.5-mm locking compression plate tensioned and linked to a femoral reconstruction nail through interlocking screws with immediate weight-bearing. CONCLUSION A plate-tensioned-nail construct is a single-stage salvage option for a length-unstable subtrochanteric nonunion which permits immediate full weight-bearing.
Collapse
Affiliation(s)
- Joseph T Patterson
- Department of Orthopaedic Surgery, Keck School of Medicine of the University of Southern California, Los Angeles, California
| |
Collapse
|
24
|
Jellesen MS, Lomholt TN, Hansen RQ, Mathiesen T, Gundlach C, Kold S, Nygaard T, Mikuzis M, Olesen UK, Rölfing JD. The STRYDE limb lengthening nail is susceptible to mechanically assisted crevice corrosion: an analysis of 23 retrieved implants. Acta Orthop 2021; 92:621-627. [PMID: 34102950 PMCID: PMC8519523 DOI: 10.1080/17453674.2021.1927506] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - We noted several adverse events in patients in whom the first version of the STRYDE limb-lengthening nail (NuVasive Specialized Orthopaedics, San Diego, CA) had been implanted. Pain, osteolysis, periosteal reactions, and cortical hypertrophy at the nail junction were noted. Here, we present the analysis of 23 retrieved STRYDE implants.Materials and methods - We undertook visual inspection of the retrieved nails and screws, mechanical evaluation of the junction, micro-CT analyses, microscopic inspection of the bushing, screws, screw holes, and separated parts of the implants. Positive material identification (PMI) and energy-dispersive X-ray spectroscopy (EDS) were used to analyze the chemical composition. The hardness of the material was also investigated.Results - 20/23 retrieved nails had visible signs of corrosion, i.e., discoloration at the telescopic junction. Micro-CT verified corrosion attacks in 12/12 scanned bushings. Corrosion, predominantly mechanically assisted crevice corrosion, was observed at the locking screws and screw holes in 20/23 nails. Biological material inside the nail was observed in addition to oozing from the junction of 2 nails during hardware removal, which was experimentally reproducible. Notably, the mechanical construction of the bushing changed from PRECICE P2 to STRYDE nails.Interpretation - STRYDE nails are not hermetically sealed, and liquid can pass the bushing. Biodur 108 itself is corrosion resistant; however, mechanically assisted crevice corrosion of the bushing, locking screws, and screw holes may be aggravated due to manufacturing aiming for increased strength and hardness of the alloy.Observing several adverse events, we recently published a nationwide cross-sectional analysis of all 30 STRYDE limb- lengthening nails (NuVasive, Specialized Orthopedics, San Diego, CA) that were implanted in Denmark (Rölfing et al. 2021a). 27/30 STRYDE nails have now been removed and we present data from metallurgical analysis of 23 of the retrieved implants.
Collapse
Affiliation(s)
| | | | - Rikke Quist Hansen
- Department of Mechanical Engineering, Technical University of Denmark, Lyngby; ,Materials and Product Testing, FORCE Technology, Brøndby;
| | | | | | - Søren Kold
- Department of Orthopaedics, Interdisciplinary Orthopaedics, Aalborg University Hospital, Aalborg;
| | - Tobias Nygaard
- Department of Orthopaedics, Limb Lengthening and Bone Reconstruction Unit, Rigshospitalet, Copenhagen;
| | - Mindaugas Mikuzis
- Department of Orthopaedics, Interdisciplinary Orthopaedics, Aalborg University Hospital, Aalborg;
| | - Ulrik Kähler Olesen
- Department of Orthopaedics, Limb Lengthening and Bone Reconstruction Unit, Rigshospitalet, Copenhagen;
| | - Jan Duedal Rölfing
- Orthopaedic Reconstruction and Children’s Orthopaedics, Aarhus University Hospital, Aarhus, Denmark,Jan Duedal Rölfing Correspondence: Orthopaedic Reconstruction and Children’s Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
25
|
Hothi H, Bergiers S, Henckel J, Iliadis AD, Goodier WD, Wright J, Skinner J, Calder P, Hart AJ. Analysis of retrieved STRYDE nails. Bone Jt Open 2021; 2:599-610. [PMID: 34352183 PMCID: PMC8384447 DOI: 10.1302/2633-1462.28.bjo-2021-0126] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Aims The aim of this study was to present the first retrieval analysis findings of PRECICE STRYDE intermedullary nails removed from patients, providing useful information in the post-market surveillance of these recently introduced devices. Methods We collected ten nails removed from six patients, together with patient clinical data and plain radiograph imaging. We performed macro- and microscopic analysis of all surfaces and graded the presence of corrosion using validated semiquantitative scoring methods. We determined the elemental composition of surface debris using energy dispersive x-ray spectroscopy (EDS) and used metrology analysis to characterize the surface adjacent to the extendable junctions. Results All nails were removed at the end of treatment, having achieved their intended lengthening (20 mm to 65 mm) and after regenerate consolidation. All nails had evidence of corrosion localized to the screw holes and the extendable junctions; corrosion was graded as moderate at the junction of one nail and severe at the junctions of five nails. EDS analysis showed surface deposits to be chromium rich. Plain radiographs showed cortical thickening and osteolysis around the junction of six nails, corresponding to the same nails with moderate – severe junction corrosion. Conclusion We found, in fully united bones, evidence of cortical thickening and osteolysis that appeared to be associated with corrosion at the extendable junction; when corrosion was present, cortical thickening was adjacent to this junction. Further work, with greater numbers of retrievals, is required to fully understand this association between corrosion and bony changes, and the influencing surgeon, implant, and patient factors involved. Cite this article: Bone Jt Open 2021;2(8):599–610.
Collapse
Affiliation(s)
- Harry Hothi
- The Royal National Orthopaedic Hospital, London, UK
| | | | | | | | | | - Jonathan Wright
- The Royal National Orthopaedic Hospital, London, UK.,The Royal London Hospital, Barts Health NHS Trust, London, UK
| | - John Skinner
- The Royal National Orthopaedic Hospital, London, UK
| | - Peter Calder
- The Royal National Orthopaedic Hospital, London, UK
| | | |
Collapse
|
26
|
Frommer A, Roedl R, Gosheger G, Hasselmann J, Fuest C, Toporowski G, Laufer A, Tretow H, Schulze M, Vogt B. Focal osteolysis and corrosion at the junction of Precice Stryde intramedullary lengthening device : preliminary clinical, radiological, and metallurgic analysis of 57 lengthened segments. Bone Joint Res 2021; 10:425-436. [PMID: 34269599 PMCID: PMC8333033 DOI: 10.1302/2046-3758.107.bjr-2021-0146.r1] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Aims This study aims to enhance understanding of clinical and radiological consequences and involved mechanisms that led to corrosion of the Precice Stryde (Stryde) intramedullary lengthening nail in the post market surveillance era of the device. Between 2018 and 2021 more than 2,000 Stryde nails have been implanted worldwide. However, the outcome of treatment with the Stryde system is insufficiently reported. Methods This is a retrospective single-centre study analyzing outcome of 57 consecutive lengthening procedures performed with the Stryde nail at the authors’ institution from February 2019 until November 2020. Macro- and microscopic metallographic analysis of four retrieved nails was conducted. To investigate observed corrosion at telescoping junction, scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX) were performed. Results Adjacent to the nail’s telescoping junction, osteolytic changes were observed in bi-planar radiographs of 20/57 segments (35%) after a mean of 9.5 months (95% confidence interval 7.2 to 11.9) after surgery. A total of 8/20 patients with osseous alterations (40%) reported rest and ambulation pain of the lengthened segment during consolidation. So far, 24 Stryde nails were retrieved and in 20 (83%) macroscopic corrosion was observed at the nail’s telescoping junction. Before implant removal 11/20 radiographs (55%) of lengthened segments with these 20 nails revealed osteolysis. Implant retrieval analysis by means of SEM showed pitting and crevice corrosion. EDX detected chromium as the main metallic element of corrosion. Conclusion Patients are exposed to the risk of implant-related osteolysis of unclear short- and long-term clinical consequences. The authors advocate in favour of an early implant removal after osseous consolidation. Cite this article: Bone Joint Res 2021;10(7):425–436.
Collapse
Affiliation(s)
- Adrien Frommer
- Pediatric Orthopedics, Deformity Reconstruction and Foot Surgery, University Hospital of Muenster, Muenster, Germany
| | - Robert Roedl
- Pediatric Orthopedics, Deformity Reconstruction and Foot Surgery, University Hospital of Muenster, Muenster, Germany
| | - Georg Gosheger
- General Orthopedics and Tumor Orthopedics, University Hospital of Muenster, Muenster, Germany
| | - Julian Hasselmann
- Materials Technology Laboratory at the Department of Mechanical Engineering, Muenster University of Applied Sciences, Muenster, Germany
| | - Cordula Fuest
- Materials Technology Laboratory at the Department of Mechanical Engineering, Muenster University of Applied Sciences, Muenster, Germany
| | - Gregor Toporowski
- Pediatric Orthopedics, Deformity Reconstruction and Foot Surgery, University Hospital of Muenster, Muenster, Germany
| | - Andrea Laufer
- Pediatric Orthopedics, Deformity Reconstruction and Foot Surgery, University Hospital of Muenster, Muenster, Germany
| | - Henning Tretow
- Pediatric Orthopedics, Deformity Reconstruction and Foot Surgery, University Hospital of Muenster, Muenster, Germany
| | - Martin Schulze
- General Orthopedics and Tumor Orthopedics, University Hospital of Muenster, Muenster, Germany
| | - Bjoern Vogt
- Pediatric Orthopedics, Deformity Reconstruction and Foot Surgery, University Hospital of Muenster, Muenster, Germany
| |
Collapse
|
27
|
Teulières M, Langlais T, de Gauzy JS, Rölfing JD, Accadbled F. Bone Lengthening with a Motorized Intramedullary Nail in 34 Patients with Posttraumatic Limb Length Discrepancies. J Clin Med 2021; 10:2393. [PMID: 34071540 PMCID: PMC8198387 DOI: 10.3390/jcm10112393] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2021] [Revised: 05/23/2021] [Accepted: 05/26/2021] [Indexed: 11/29/2022] Open
Abstract
The Fitbone® motorized nail system has been used to correct limb length discrepancies (LLD) for several years. This study focuses on its application in posttraumatic limb lengthening surgery, its outcome and challenges. MATERIALS AND METHODS A prospective, single center study was conducted between 2010 and 2019 in patients treated with motorized lengthening nails. The inclusion criteria were symptomatic LLD of 20 mm or more. An imaging analysis was done using TraumaCad® software (Brainlab AG, Munich, Germany) to compare frontal alignment angles and limb length discrepancy (LLD) on preoperative and latest follow-up radiographs of the lower limbs. RESULTS Thirty-four patients were included with a mean age of 28.8 ± 9.7 years, a mean follow-up of 27.8 ± 13 months and a mean hospital stay of 4.4 ± 1.7 days. The mean LLD was 44 ± 18 mm in 29 femoral and 32 ± 8 mm in 4 tibial cases, which was reduced to less than 10 mm in 25/34 (74%) patients. The mean healing index was 84.6 ± 62.5 days/cm for femurs and 92 ± 38.6 days/cm for tibias. The mean time to resume full weight-bearing without walking aids was 226 days ± 133. There was no significant difference between preoperative and final follow-up alignment angles and range of motion. The mechanical lateral distal femoral angle (mLDFA) was corrected in the subgroup of 10 LLD patients with varus deformity of the femur (preoperative 95.7° (±5.0) vs. postoperative 91.5° (±3.4), p = 0.008). According to Paley's classification, there were 14 problems, 10 obstacles and 2 complications. DISCUSSION Six instances of locking screw pull out, often requiring reoperation, raise the question of whether a more systematic use of blocking screws that provide greater stability might be indicated. Lack of compliance can lead to poor outcomes, patient selection in posttraumatic LLD patients is therefore important. CONCLUSION Limb lengthening with a motorized lengthening nail for posttraumatic LLD is a relatively safe and reliable procedure. Full patient compliance is crucial. In-depth knowledge of lengthening and deformity correction techniques is essential to prevent and manage complications.
Collapse
Affiliation(s)
- Maxime Teulières
- Department of Pediatric Orthopaedics, CHU de Toulouse, 31300 Toulouse, France; (M.T.); (T.L.); (J.S.d.G.)
| | - Tristan Langlais
- Department of Pediatric Orthopaedics, CHU de Toulouse, 31300 Toulouse, France; (M.T.); (T.L.); (J.S.d.G.)
| | - Jérôme Sales de Gauzy
- Department of Pediatric Orthopaedics, CHU de Toulouse, 31300 Toulouse, France; (M.T.); (T.L.); (J.S.d.G.)
| | - Jan Duedal Rölfing
- Children’s Orthopaedics and Reconstruction, Aarhus University Hospital, 8200 Aarhus, Denmark;
| | - Franck Accadbled
- Department of Pediatric Orthopaedics, CHU de Toulouse, 31300 Toulouse, France; (M.T.); (T.L.); (J.S.d.G.)
| |
Collapse
|