1
|
Chan AW, Lin H, Yacoub I, Chhabra AM, Choi JI, Simone CB. Proton Therapy in Uveal Melanoma. Cancers (Basel) 2024; 16:3497. [PMID: 39456591 PMCID: PMC11506608 DOI: 10.3390/cancers16203497] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2024] [Revised: 10/08/2024] [Accepted: 10/11/2024] [Indexed: 10/28/2024] Open
Abstract
Background/Objectives: Uveal melanoma is the most common primary intraocular malignancy in adults. Treatment options for localized, early-stage disease include enucleation, brachytherapy, and proton beam therapy. This review aims to evaluate the role of proton therapy in the definitive management of uveal melanoma, focusing on its physics, radiobiology, treatment techniques, and associated outcomes. Methods: This narrative review synthesizes current literature on proton therapy for uveal melanoma, emphasizing case selection, treatment efficacy, and side effects. Results: Proton therapy offers significant advantages for thicker uveal melanomas (over 8 mm) due to its unique physical properties, including a rapid dose fall-off that protects critical structures like the retina and optic nerve. Proton therapy may have benefits in tumor control for ocular melanomas given its increased relative biological effectiveness relative to photon therapy for these typically more radioresistant melanomas. Proton therapy may also hold special value for uveal melanomas in close proximity to the optic nerve, as patients are at high risk of visual toxicities with brachytherapy. The review discusses the efficacy of proton therapy across small, medium, and large tumors, along with strategies for improving patient survival through combined systemic therapy. Additionally, the potential of ocular reirradiation with proton therapy is addressed. Conclusions: Proton therapy is an effective treatment for uveal melanoma. It offers advantages over brachytherapy for large tumors, tumors that are close to the optic nerve or insertion of extra-ocular muscles.
Collapse
Affiliation(s)
- Adrian Wai Chan
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, The University of Toronto, Toronto, ON M4N 3M5, Canada
| | - Haibo Lin
- New York Proton Center, New York, NY 10035, USA
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA
| | | | | | - J. Isabelle Choi
- New York Proton Center, New York, NY 10035, USA
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA
| | - Charles B. Simone
- New York Proton Center, New York, NY 10035, USA
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA
| |
Collapse
|
2
|
Noureldine AM, Hamza H, Khattab AM, Macky TA, Hassanein DH, Abdullatif AM, Salem DS, Salah SH. B-scan measurements of intraocular tumor heights intraoperatively, before and after radioactive plaque application: A comparative prospective study. J Fr Ophtalmol 2024; 47:103941. [PMID: 37730496 DOI: 10.1016/j.jfo.2023.04.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 03/14/2023] [Accepted: 04/05/2023] [Indexed: 09/22/2023]
Abstract
PURPOSE To assess the difference in intraocular tumors height measurements intraoperatively before and after radioactive plaque application. METHODOLOGY Twenty-four eyes of 24 patients with intraocular tumors, candidates for radioactive therapy, were included. Each tumor was measured at the same setting before and after plaque application independently by 3 sonographers, using a 20-MHz B-scan transducer. Mean pre-plaque and post-plaque measurements were calculated and recorded. An A-scan vector aided in identification of the inner and outer tumor surfaces. RESULTS Each patient was examined independently three times by three experienced ultrasonographers within the same setting to assess interobserver variability. There was no statistically significant difference between the 3 examiners' readings, with P-value 0.99 for pre-plaque height and 0.97 for post-plaque height. Mean pre-plaque height was 5.16±2.11mm, while post-plaque height was 5.51±2.1mm (P-value 0.001). The Spearman correlation test showed that initial tumor height was negatively correlated with the difference between both heights, but with no statistical significance. CONCLUSION Intraocular tumor height measurement differs significantly before and after plaque application. Use of the pre-plaque height is advised until further studies are performed to assess the effect of this difference on treatment outcomes.
Collapse
Affiliation(s)
| | - H Hamza
- Faculty of medicine, Cairo university, Cairo, Egypt
| | - A M Khattab
- Faculty of medicine, Cairo university, Cairo, Egypt
| | - T A Macky
- Faculty of medicine, Cairo university, Cairo, Egypt
| | | | | | - D S Salem
- Faculty of medicine, Cairo university, Cairo, Egypt
| | - S H Salah
- Faculty of medicine, Cairo university, Cairo, Egypt
| |
Collapse
|
3
|
Kheir WJ, Stinnett SS, Meltsner S, Semenova E, Mowery YM, Craciunescu O, Kirsch DG, Materin MA. Preliminary Results of Uveal Melanoma Treated With Iodine-125 Plaques: Analysis of Disease Control and Visual Outcomes With 63 Gy to the Target Volume. Adv Radiat Oncol 2022; 7:100869. [PMID: 35387419 PMCID: PMC8977858 DOI: 10.1016/j.adro.2021.100869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Accepted: 09/26/2021] [Indexed: 11/25/2022] Open
Abstract
Purpose Our purpose was to review the preliminary outcomes of patients with uveal melanoma treated with iodine-125 plaques using a novel treatment planning approach. Methods and Materials This was a single institution, retrospective review of patients treated with iodine-125 brachytherapy for uveal melanoma from November 2016 to February 2019. We used 3-dimensional treatment planning with the Eye Physics Plaque Simulator to ensure that a minimum of 63 Gy covered a 2-mm circumferential tumor margin and the apex height of the tumor over 94 hours. Primary endpoints were local failure, systemic metastasis, final visual acuity (VA), and radiation retinopathy. Associations between primary endpoints and tumor characteristics/radiation dose were performed using univariate analysis. Results Sixty-nine patients were included in the analysis. Mean largest basal diameter was 11.67 mm (range, 6-18; median, 12), and the average tumor thickness to the inner sclera was 3.18 mm (range, 0.5-9.3; median, 2.8). Molecular testing that was successfully performed in 59 patients revealed that 27% (16 of 59) had class 2 gene expression profile designation. Average follow-up posttreatment was 28.3 months (range, 4-46; median, 29), with 6% (4 of 69) developing local failure and 6% (4 of 69) developing metastasis over this duration. Average final VA (0.57 logMAR [Snellen 20/74]; range, 0-2.9; median, 0.3) was decreased from baseline (0.34 logMAR [Snellen 20/44]; range, 0-2.3; median, 0.1), and 48% (33 of 69) developed radiation retinopathy. Fifty percent of patients had a final VA 20/40 or better and 22% had a final VA 20/200 or worse. Conclusions In patients with uveal melanoma, preliminary results with brachytherapy using Eye Physics plaques with a treatment plan that delivers 63 Gy to a 2-mm circumferential tumor margin and the tumor apex suggest effective disease control and favorable VA outcomes.
Collapse
Affiliation(s)
| | | | | | | | | | | | - David G. Kirsch
- Radiation Oncology
- Pharmacology and Cancer Biology, Duke University Medical Center, Durham, North Carolina
| | | |
Collapse
|
4
|
Buonanno F, Conson M, de Almeida Ribeiro C, Oliviero C, Itta F, Liuzzi R, Pacelli R, Cella L, Clemente S. Local tumor control and treatment related toxicity after plaque brachytherapy for uveal melanoma: A systematic review and a data pooled analysis. Radiother Oncol 2021; 166:15-25. [PMID: 34774654 DOI: 10.1016/j.radonc.2021.11.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Revised: 10/29/2021] [Accepted: 11/02/2021] [Indexed: 01/02/2023]
Abstract
Uveal melanoma (UM) represents the most common primary intraocular tumor, and nowadays eye plaque brachytherapy (EPB) is the most frequently used visual acuity preservation treatment option for small to medium sized UMs. The excellent local tumor control (LTC) rate achieved by EPB may be associated with severe complications and adverse events. Several dosimetric and clinical risk factors for the development of EPB-related ocular morbidity can be identified. However, morbidity predictive models specifically developed for EPB are still scarce. PRISMA methodology was used for the present systematic review of articles indexed in PubMed in the last sixteen years on EPB treatment of UM which aims at determining the major factors affecting local tumor control and ocular morbidities. To our knowledge, for the first time in EPB field, local tumor control probability (TCP) and normal tissue complication probability (NTCP) modelling on pooled clinical outcomes were performed. The analyzed literature (103 studies including 21,263 UM patients) pointed out that Ru-106 EPB provided high local control outcomes while minimizing radiation induced complications. The use of treatment planning systems (TPS) was the most influencing factor for EPB outcomes such as metastasis occurrence, enucleation, and disease specific survival, irrespective of radioactive implant type. TCP and NTCP parameters were successfully extracted for 5-year LTC, cataract and optic neuropathy. In future studies, more consistent recordings of ocular morbidities along with accurate estimation of doses through routine use of TPS are needed to expand and improve the robustness of toxicity risk prediction in EPB.
Collapse
Affiliation(s)
- Francesca Buonanno
- University Federico II, Post Graduate School in Medical Physics, Department of Advanced Biomedical Sciences, Napoli, Italy
| | - Manuel Conson
- University Federico II, Department of Advanced Biomedical Sciences, Napoli, Italy
| | | | - Caterina Oliviero
- University Hospital Federico II, Unit of Medical Physics and Radioprotection, Napoli, Italy
| | - Francesca Itta
- University Federico II, Post Graduate School in Medical Physics, Department of Advanced Biomedical Sciences, Napoli, Italy
| | - Raffaele Liuzzi
- National Research Council (CNR), Institute of Biostructures and Bioimaging, Napoli, Italy
| | - Roberto Pacelli
- University Federico II, Department of Advanced Biomedical Sciences, Napoli, Italy
| | - Laura Cella
- National Research Council (CNR), Institute of Biostructures and Bioimaging, Napoli, Italy.
| | - Stefania Clemente
- University Hospital Federico II, Unit of Medical Physics and Radioprotection, Napoli, Italy
| |
Collapse
|
5
|
Fam A, Tomar AS, Finger PT. OCT-A evaluation of radiation vasculopathy following slotted plaque brachytherapy. Eur J Ophthalmol 2021; 32:2459-2568. [PMID: 34528465 DOI: 10.1177/11206721211044339] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To determine a reliable diagnostic method to reveal and monitor subclinical progression of neural and perineural radiation vasculopathy. METHODS A retrospective cross-sectional study, where optical coherence tomography angiography (OCT-A) imaging data was collected and analyzed from 22 consecutive patients that had been treated with circumneural slotted plaque brachytherapy for peripapillary, juxtapapillary, or circumpapillary choroidal melanomas. Pre-operative dosimetry of palladium-103 radiation dose to the optic nerve and fovea were collected. Quantified differences in OCT-A-measured vessel density and length in treated verses untreated contralateral control eyes were collected. Vessel density and length were correlated to radiation dose, plaque slot depth, visual acuity outcomes, and circumpapillary retinal nerve fiber layer thickness. RESULTS Patients had post-irradiation follow-up of median 39 months, interquartile range 62 months). The mean optic disc radiation dose was 89.9 Gy ± 39.2 (86.5, 30.8-189.0). In comparison to controls, OCT-A imaging revealed significant differences in radial peripapillary capillary vessel density (18 μm2 in case eyes, 34 μm2 in control eyes; p < 0.001) and length (10 μm in case eyes, 14 μm in control eyes; p < 0.001). Change in vessel density did not show a significant correlation to radiation dose, slot depth, or visual acuity. However, change in vessel length was significantly correlated to radiation dose (p = 0.049) and change in visual acuity (p < 0.001). CONCLUSIONS OCT-A imaging revealed that radial peripapillary capillary vessel density and length were significantly reduced after circumneural irradiation for choroidal melanoma. Therefore, OCT-A imaging can be used to monitor progression of papillary vasculopathy associated with radiation optic neuropathy.
Collapse
Affiliation(s)
- Anthony Fam
- The New York Eye Cancer Center, New York, NY, USA
| | | | | |
Collapse
|