1
|
Zhang C, Zhao L, Ma X, Zhang Z, Fan Z. A feasibility study of an intravascular imaging antenna to image atherosclerotic plaques in Swine using 3.0 T MRI. PLoS One 2014; 9:e108301. [PMID: 25259585 PMCID: PMC4178132 DOI: 10.1371/journal.pone.0108301] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2014] [Accepted: 08/28/2014] [Indexed: 12/04/2022] Open
Abstract
Purpose To investigate the feasibility of an intravascular imaging antenna to image abdominal aorta atherosclerotic plaque in swine using 3.0T magnetic resonance imaging (MRI). Methods Atherosclerotic model was established in 6 swine. After 8 months, swine underwent an MR examination, which was performed using an intravascular imaging guide-wire, and images of the common iliac artery and the abdominal aorta were acquired. Intravascular ultrasound (IVUS) was performed in the right femoral artery; images at the same position as for the MR examination were obtained. The luminal border and external elastic membrane of the targeted arteries were individually drawn in the MR and IVUS images. After co-registering these images, the vessel, lumen, and vessel wall areas and the plaque burden in the same lesions imaged using different modalities were calculated and compared. The diagnostic accuracy of intravascular MR examination in delineating the vessel wall and detecting plaques were analyzed and compared using IVUS. Results Compared with IVUS, good agreement was found between MRI and IVUS for delineating vessel, lumen, and vessel wall areas and plaque burden (r value: 0.98, 0.95, 0.96 and 0.91, respectively; P<0.001). Conclusion Compared with IVUS, using an intravascular imaging guide-wire to image deep seated arteries allowed determination of the vessel, lumen and vessel wall areas and plaque size and burden. This may provide an alternative method for detecting atherosclerotic plaques in the future.
Collapse
Affiliation(s)
- Chen Zhang
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
| | - Lei Zhao
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
| | - Xiaohai Ma
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
- * E-mail:
| | - Zhaoqi Zhang
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
| | - Zhanming Fan
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
2
|
Zhang F, Le T, Wu X, Wang H, Zhang T, Meng Y, Wei B, Soriano SS, Willis P, Kolokythas O, Yang X. Intrabiliary RF heat-enhanced local chemotherapy of a cholangiocarcinoma cell line: monitoring with dual-modality imaging--preclinical study. Radiology 2013; 270:400-8. [PMID: 24471389 DOI: 10.1148/radiol.13130866] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
PURPOSE To determine whether magnetic resonance (MR) imaging heating guidewire-mediated radiofrequency (RF) hyperthermia could enhance the therapeutic effect of gemcitabine and 5-fluorouracil (5-FU) in a cholangiocarcinoma cell line and local deposit doses of chemotherapeutic drugs in swine common bile duct (CBD) walls. MATERIALS AND METHODS The animal protocol was approved by the institutional animal care and use committee. Green fluorescent protein-labeled human cholangiocarcinoma cells and cholangiocarcinomas in 24 mice were treated with (a) combination therapy with chemotherapy (gemcitabine and 5-FU) plus RF hyperthermia, (b) chemotherapy only, (c) RF hyperthermia only, or (d) phosphate-buffered saline. Cell proliferation was quantified, and tumor changes over time were monitored with 14.0-T MR imaging and optical imaging. To enable further validation of technical feasibility, intrabiliary local delivery of gemcitabine and 5-FU was performed by using a microporous balloon with (eight pigs) or without (eight pigs) RF hyperthermia. Chemotherapy deposit doses in the bile duct walls were quantified by means of high-pressure liquid chromatography. The nonparametric Mann-Whitney U test and the paired-sample Wilcoxon signed rank test were used for data analysis. RESULTS Combination therapy induced lower mean levels of cell proliferation than chemotherapy only and RF hyperthermia only (0.39 ± 0.13 [standard deviation] vs 0.87 ± 0.10 and 1.03 ± 0.13, P < .001). Combination therapy resulted in smaller relative tumor volume than chemotherapy only and RF hyperthermia only (0.65 ± 0.03 vs 1.30 ± 0.021 and 1.37 ± 0.05, P = .001). Only in the combination therapy group did both MR imaging and optical imaging show substantial decreases in apparent diffusion coefficients and fluorescent signals in tumor masses immediately after the treatments. Chemotherapy quantification showed a higher average drug deposit dose in swine CBD walls with intrabiliary RF hyperthermia than without it (gemcitabine: 0.32 mg/g of tissue ± 0.033 vs 0.260 mg/g ± 0.030 and 5-FU: 0.660 mg/g ± 0.060 vs 0.52 mg/g ± 0.050, P < .05). CONCLUSION The use of intrabiliary MR imaging heating guidewire-mediated RF hyperthermia can enhance the chemotherapeutic effect on a human cholangiocarcinoma cell line and local drug deposition in swine CBD tissues.
Collapse
Affiliation(s)
- Feng Zhang
- From the Image-Guided Bio-Molecular Intervention Research and Section of Vascular & Interventional Radiology, Department of Radiology, Institute for Stem Cell and Regenerative Medicine, University of Washington School of Medicine, 850 Republican St, Seattle, WA 98109
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Zhang F, Li J, Meng Y, Sun J, Soriano SS, Willis P, Gu H, Glickerman D, Yang X. Development of an intrabiliary MR imaging-monitored local agent delivery technique: a feasibility study in pigs. Radiology 2012; 262:846-52. [PMID: 22357886 DOI: 10.1148/radiol.11110723] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To investigate the feasibility of using magnetic resonance (MR) imaging to monitor intrabiliary delivery of motexafin gadolinium (MGd) into pig common bile duct (CBD) walls. MATERIALS AND METHODS Animal studies were approved by the Institutional Animal Care and Use Committee. Initially, human cholangiocarcinoma cells were treated with various concentrations of MGd, a compound serving as a T1-weighted MR imaging contrast agent, chemotherapy drug, and cell marker. These cells were then examined by means of confocal microscopy to confirm the intracellular uptake of MGd. In addition, an MGd/trypan blue mixture was locally infused into CBD walls of six cadaveric pigs using a microporous balloon catheter. CBDs of six pigs were infused with saline to serve as controls. Ex vivo T1-weighted MR imaging of these CBDs was performed. For in vivo technical validation, the microporous balloon catheter was placed in the CBD by means of a transcholecytic access to deliver MGd/trypan blue into CBD walls of six living pigs. T1-weighted images were obtained with both a surface coil and an intrabiliary MR imaging guidewire, and contrast-to-noise ratios of CBD walls before and after MGd/trypan blue infusions were compared in the two groups by means of paired t test, with subsequent histologic analysis to confirm the penetration and distribution of the MGd/trypan blue agent into CBD walls. RESULTS In vitro experiments confirmed uptake of MGd by human cholangiocarcinoma cells. The ex vivo experiments demonstrated the penetration of MGd/trypan blue into the CBD walls. The in vivo experiment confirmed the uptake of MGd/trypan blue, showing an increased contrast-to-noise ratio for the CBD after administration of the mixture, compared with images obtained prior to MGd/trypan blue administration (11.6 ± 4.2 [standard deviation] vs 5.7 ± 2.8; P = .04). Histologic results depicted the blue dye stains and red fluorescence of MGd in CBD walls, confirming the imaging findings. CONCLUSION It is feasible to use MR imaging to monitor the penetration of locally delivered MGd into pig CBD walls.
Collapse
Affiliation(s)
- Feng Zhang
- Image-guided Bio-Molecular Intervention Research and Section of Vascular and Interventional Radiology, Department of Radiology, Institute for Stem Cell and Regenerative Medicine, University of Washington School of Medicine, 815 Mercer St, Room S470, Seattle, WA 98109, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Gu H, Zhang F, Meng Y, Qiu B, Yang X. Development of a 0.014-in., anti-solenoid loop MR imaging guidewire for intravascular 3.0-T MR imaging. Magn Reson Imaging 2011; 29:1002-6. [PMID: 21705168 DOI: 10.1016/j.mri.2011.04.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2010] [Revised: 03/28/2011] [Accepted: 04/04/2011] [Indexed: 11/30/2022]
Abstract
PURPOSE This study aimed to develop a 0.014-in., anti-solenoid loop (ASL) magnetic resonance imaging guidewire (MRIG) for intravascular 3.0-T MR imaging. MATERIALS AND METHODS We first designed the ASL MRIG, which was made of a coaxial cable with its extended inner conductor and outer conductor connected to two micro-anti-solenoids. We then evaluated in vitro the functionality of the ASL MRIG by imaging a "vessel" in a phantom and achieving signal-to-noise ratio (SNR) and SNR contour map of the new 0.014-in. ASL MRIG. Subsequently, we validated in vivo the feasibility of using the ASL MRIG to generate intravenous 3.0-T MR images of parallel iliofemoral arteries of near-human-sized living pigs. RESULTS In vitro evaluation showed that the 0.014-in. ASL MRIG functioned well as a receiver coil with the 3.0-T MR scanner, clearly displaying the vessel wall with even distribution of MR signals and SNR contours from the ASL MRIG. Of the in vivo studies, the new ASL MRIG enabled us to successfully generate intravenous 3.0-T MR imaging of the iliofemoral arteries. CONCLUSION This study confirms that it is possible to build such small-looped MRIG at 0.014 in. for intravascular 3.0-T MR imaging.
Collapse
Affiliation(s)
- Huidong Gu
- Image-Guided Bio-Molecular Interventions Section, Department of Radiology, Institute for Stem Cell and Regenerative Medicine, University of Washington School of Medicine, Seattle, WA 98109, USA
| | | | | | | | | |
Collapse
|
5
|
Brushett C, Qiu B, Atalar E, Yang X. High-resolution MRI of deep-seated atherosclerotic arteries using motexafin gadolinium. J Magn Reson Imaging 2007; 27:246-50. [PMID: 18050320 DOI: 10.1002/jmri.21174] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Affiliation(s)
- Chris Brushett
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | | | | | | |
Collapse
|
6
|
Brzozowski L, Ganguly A, Pop M, Wen Z, Bennett R, Fahrig R, Rowlands JA. Compatibility of interventional x-ray and magnetic resonance imaging: feasibility of a closed bore XMR (CBXMR) system. Med Phys 2006; 33:3033-45. [PMID: 16964881 DOI: 10.1118/1.2219328] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
A next-generation interventional guidance system is proposed that will enable intraprocedural access to both x-ray and magnetic resonance imaging (MRI) modalities. This closed bore XMR (CBXMR) system is comprised of a conventional radiographic rotating anode x-ray tube and a direct conversion flat panel detector on a rotating gantry positioned adjacent to the bore of a 1.5 T MRI. To assess the feasibility of such a system, we have investigated the degree of compatibility between the x-ray components and the MRI. For /-->B(ext)/ < 200 G the effect on the radiographic tube motor was negligible regardless of the orientation of -->B(ext) with respect to the motor axis of rotation--the frequency of anode rotation remained within 6% of the 3400 rpm frequency measured at 0 G. For /-->B(ext)/ >2400 G the anode slowed down to below 2400 rpm at all orientations. At intermediate B(ext), the frequency of rotation varied between 2400 and 3200 rpm, showing a strong dependence on orientation, with -->B(ext) perpendicular to the tube axis having a much stronger effect on the rotation frequency than -->B(ext) parallel to the tube axis. In contrast to the effect of -->B(ext) on the induction motor, parallel -->B(ext) had a stronger detrimental effect on the cathode-anode electron beam, whose path was at 16 degrees to the tube axis, than the perpendicular -->B(ext). Parallel -->B(ext) of several hundred Gauss had a defocusing effect on the x-ray focal spot. -->B(ext) perpendicular to the electron beam shifted the beam without significant defocusing. We have determined that the direct conversion flat panel detector (FPD) technology is not intrinsically sensitive to -->B(ext), and that the modifications required to make the proposed FPDs MRI compatible are minimal. The homogeneity of the MRI signal in the normal field of view was not significantly degraded by the presence of these x-ray components in the vicinity of the MRI bore entrance.
Collapse
Affiliation(s)
- Lukasz Brzozowski
- Department of Medical Biophysics, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5, Canada
| | | | | | | | | | | | | |
Collapse
|
7
|
van Straten A, Vliegen HW, Hazekamp MG, de Roos A. Right ventricular function late after total repair of tetralogy of Fallot. Eur Radiol 2005; 15:702-7. [PMID: 15726380 DOI: 10.1007/s00330-004-2574-z] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2004] [Revised: 10/04/2004] [Accepted: 10/12/2004] [Indexed: 11/28/2022]
Abstract
Over the past decades, life expectancy in patients with congenital heart disease has increased dramatically. However, serious complications may develop late after total repair in infancy. These complications are usually the result of longstanding pulmonary regurgitation, which leads to dilatation of the right ventricle and an increased risk for severe arrhythmias. Therefore lifelong follow-up in these patients is required. Cardiac magnetic resonance imaging is the current imaging tool of choice because it offers superior imaging quality and enables accurate quantification of functional parameters such as flow volumes and systolic and diastolic performance.
Collapse
Affiliation(s)
- Alexander van Straten
- Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 Leiden, The Netherlands.
| | | | | | | |
Collapse
|
8
|
Abstract
Gene therapy is an exciting frontier in medicine today. Many genes have been shown to be useful for treatment of various vascular diseases, including chronic cardiac and limb ischemia syndromes, vasculoproliferative disorder, hypercholesterolemia, atherosclerosis, thrombosis, and hypertension. Precise delivery of genes into target vessels, efficient transfer of genes into vascular cells of the target, and prompt assessment of gene expression over time are three challenging tasks for successful vascular gene therapy. Thus, in vivo imaging methods that can be used to monitor gene delivery and localize gene expression are needed. Modern imaging techniques provide an opportunity to monitor and direct vascular gene therapy. Radiologists play a key role not only in developing and mastering endovascular genetic interventions but also in assessing the success of vascular gene therapy and directing further refinement of vascular gene therapy technology. This article provides an overview of the current status of imaging of vascular gene therapy.
Collapse
Affiliation(s)
- Xiaoming Yang
- Department of Radiology, Johns Hopkins University School of Medicine, Traylor Bldg, Rm 330, 720 Rutland Ave, Baltimore, MD 21205, USA.
| |
Collapse
|
9
|
Yang X, Atalar E. Intravascular MR imaging-guided balloon angioplasty with an MR imaging guide wire: feasibility study in rabbits. Radiology 2000; 217:501-6. [PMID: 11058652 DOI: 10.1148/radiology.217.2.r00oc17501] [Citation(s) in RCA: 61] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To develop a technique for intravascular magnetic resonance (MR)-guided balloon angioplasty with use of an MR imaging guide wire. MATERIALS AND METHODS An MR imaging guide wire (0.6-mm loopless antenna) that could be placed within a balloon catheter was manufactured. The guide wire was expected to function as either an MR receiver probe in real-time MR imaging or a guide wire for use with interventional devices. Laparotomy was performed in eight rabbits, and a dilatable stenosis was created at the upper abdominal aorta. Balloon angioplasty, validated at pre- and postoperative MR aortography with renal contrast enhancement was performed by using a 1.5-T MR unit with a fast spoiled gradient-echo pulse sequence, short repetition and echo times, and a rate of three frames per second. RESULTS During MR tracking, the entire length of the MR imaging guide wire was always visible as a band of high signal intensity. In all cases, the MR imaging guide wires were passed through the aortic stenoses dilated by means of balloon inflation. Before balloon angioplasty, flow in the aorta distal to the stenosis was decreased, which caused mild contrast enhancement in each kidney. After balloon angioplasty, distal flow was restored, resulting in substantial renal enhancement. CONCLUSION The MR imaging guide wire is a potential tool for use in endovascular interventional MR imaging.
Collapse
Affiliation(s)
- X Yang
- Department of Radiology, Johns Hopkins University School of Medicine, Outpatient Center Rm 4243, 601 N Caroline St, Baltimore MD 21287-0845, USA.
| | | |
Collapse
|
10
|
Serfaty JM, Yang X, Aksit P, Quick HH, Solaiyappan M, Atalar E. Toward MRI-guided coronary catheterization: visualization of guiding catheters, guidewires, and anatomy in real time. J Magn Reson Imaging 2000; 12:590-4. [PMID: 11042641 DOI: 10.1002/1522-2586(200010)12:4<590::aid-jmri11>3.0.co;2-3] [Citation(s) in RCA: 71] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
The success of x-ray fluoroscopy-guided coronary catheterization depends in part on the ability to obtain simultaneous and real-time visualization of the guidewire, guiding catheter, and anatomy of the chest. The hypothesis explored in this paper is that magnetic resonance imaging (MRI) could provide this ability. This hypothesis was tested with loopless antennas used as the guidewire and a guiding catheter and two surface coils, each connected to four different receiver channels of a GE 1.5-T CV/I MRI scanner. Experiments were conducted on six healthy dogs. Intravascular antennas were inserted in the right carotid artery and maneuvered in the aorta while running a fast gradient-echo sequence (TR/TE 5/1.3 msec, flip angle 7 degrees). Real-time projection images of the chest anatomy, together with the guidewire and guiding catheter, were obtained. Positioning of the MRI guiding catheter either in the descending aorta, ascending aorta, or heart was achieved easily. This study represents a step toward MRI-guided coronary catheterization.
Collapse
Affiliation(s)
- J M Serfaty
- Department of Radiology and Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland 21287-0845, USA
| | | | | | | | | | | |
Collapse
|