Jin Y, Meng LJ. Exploration of Coincidence Detection of Cascade Photons to Enhance Preclinical Multi-Radionuclide SPECT Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2024; 43:1766-1781. [PMID: 38163304 DOI: 10.1109/tmi.2023.3348756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2024]
Abstract
We proposed a technique of coincidence detection of cascade photons (CDCP) to enhance preclinical SPECT imaging of therapeutic radionuclides emitting cascade photons, such as Lu-177, Ac-225, Ra-223, and In-111. We have carried out experimental studies to evaluate the proposed CDCP-SPECT imaging of low-activity radionuclides using a prototype coincidence detection system constructed with large-volume cadmium zinc telluride (CZT) imaging spectrometers and a pinhole collimator. With In-111 in experimental studies, the CDCP technique allows us to improve the signal-to-contamination in the projection (Projection-SCR) by ~53 times and reduce ~98% of the normalized contamination. Compared to traditional scatter correction, which achieves a Projection-SCR of 1.00, our CDCP method boosts it to 15.91, showing enhanced efficacy in reducing down-scattered contamination, especially at lower activities. The reconstructed images of a line source demonstrated the dramatic enhancement of the image quality with CDCP-SPECT compared to conventional and triple-energy-window-corrected SPECT data acquisition. We also introduced artificial energy blurring and Monte Carlo simulation to quantify the impact of detector performance, especially its energy resolution and timing resolution, on the enhancement through the CDCP technique. We have further demonstrated the benefits of the CDCP technique with simulation studies, which shows the potential of improving the signal-to-contamination ratio by 300 times with Ac-225, which emits cascade photons with a decay constant of ~0.1 ns. These results have demonstrated the potential of CDCP-enhanced SPECT for imaging a super-low level of therapeutic radionuclides in small animals.
Collapse
|
2
|
Zhu Y, Lyu Z, Lu W, Liu Y, Ma T. Fast and Accurate Gamma Imaging System Calibration Based on Deep Denoising Networks and Self-Adaptive Data Clustering. SENSORS (BASEL, SWITZERLAND) 2023; 23:2689. [PMID: 36904898 PMCID: PMC10007588 DOI: 10.3390/s23052689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 02/18/2023] [Accepted: 02/27/2023] [Indexed: 06/18/2023]
Abstract
Gamma imagers play a key role in both industrial and medical applications. Modern gamma imagers typically employ iterative reconstruction methods in which the system matrix (SM) is a key component to obtain high-quality images. An accurate SM could be acquired from an experimental calibration step with a point source across the FOV, but at a cost of long calibration time to suppress noise, posing challenges to real-world applications. In this work, we propose a time-efficient SM calibration approach for a 4π-view gamma imager with short-time measured SM and deep-learning-based denoising. The key steps include decomposing the SM into multiple detector response function (DRF) images, categorizing DRFs into multiple groups with a self-adaptive K-means clustering method to address sensitivity discrepancy, and independently training separate denoising deep networks for each DRF group. We investigate two denoising networks and compare them against a conventional Gaussian filtering method. The results demonstrate that the denoised SM with deep networks faithfully yields a comparable imaging performance with the long-time measured SM. The SM calibration time is reduced from 1.4 h to 8 min. We conclude that the proposed SM denoising approach is promising and effective in enhancing the productivity of the 4π-view gamma imager, and it is also generally applicable to other imaging systems that require an experimental calibration step.
Collapse
Affiliation(s)
- Yihang Zhu
- Department of Engineering Physics, Tsinghua University, Beijing 100084, China
- Key Laboratory of Particle & Radiation Imaging, Ministry of Education, Tsinghua University, Beijing 100084, China
- Institute for Precision Medicine, Tsinghua University, Beijing 100084, China
| | - Zhenlei Lyu
- Department of Engineering Physics, Tsinghua University, Beijing 100084, China
- Key Laboratory of Particle & Radiation Imaging, Ministry of Education, Tsinghua University, Beijing 100084, China
- Institute for Precision Medicine, Tsinghua University, Beijing 100084, China
| | - Wenzhuo Lu
- Department of Engineering Physics, Tsinghua University, Beijing 100084, China
- Key Laboratory of Particle & Radiation Imaging, Ministry of Education, Tsinghua University, Beijing 100084, China
| | - Yaqiang Liu
- Department of Engineering Physics, Tsinghua University, Beijing 100084, China
- Key Laboratory of Particle & Radiation Imaging, Ministry of Education, Tsinghua University, Beijing 100084, China
| | - Tianyu Ma
- Department of Engineering Physics, Tsinghua University, Beijing 100084, China
- Key Laboratory of Particle & Radiation Imaging, Ministry of Education, Tsinghua University, Beijing 100084, China
- Institute for Precision Medicine, Tsinghua University, Beijing 100084, China
| |
Collapse
|
3
|
Kennedy J, Chicheportiche A, Keidar Z. Quantitative SPECT/CT for dosimetry of peptide receptor radionuclide therapy. Semin Nucl Med 2021; 52:229-242. [PMID: 34911637 DOI: 10.1053/j.semnuclmed.2021.11.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Neuroendocrine tumors (NETs) are uncommon malignancies of increasing incidence and prevalence. As these slow growing tumors usually overexpress somatostatin receptors (SSTRs), the use of 68Ga-DOTA-peptides (gallium-68 chelated with dodecane tetra-acetic acid to somatostatin), which bind to the SSTRs, allows for PET based imaging and selection of patients for peptide receptor radionuclide therapy (PRRT). PRRT with radiolabeled somatostatin analogues such as 177Lu-DOTATATE (lutetium-177-[DOTA,Tyr3]-octreotate), is mainly used for the treatment of metastatic or inoperable NETs. However, PRRT is generally administered at a fixed injected activity in order not to exceed dose limits in critical organs, which is suboptimal given the variability in radiopharmaceutical uptake among patients. Advances in SPECT (single photon emission computed tomography) imaging enable the absolute quantitative measure of the true radiopharmaceutical distribution providing for PRRT dosimetry in each patient. Personalized PRRT based on patient-specific dosimetry could improve therapeutic efficacy by optimizing effective tumor absorbed dose while limiting treatment related radiotoxicity.
Collapse
Affiliation(s)
- John Kennedy
- Department of Nuclear Medicine, Rambam Health Care Campus, Haifa, Israel; B. Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel.
| | - Alexandre Chicheportiche
- Department of Nuclear Medicine and Biophysics, Hadassah Medical Organization and Faculty of Medicine, Hebrew University of Jerusalem, Israel
| | - Zohar Keidar
- Department of Nuclear Medicine, Rambam Health Care Campus, Haifa, Israel; B. Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel
| |
Collapse
|
4
|
Boisson F, Bekaert V, Reilhac A, Wurtz J, Brasse D. Assessment of a fast generated analytical matrix for rotating slat collimation iterative reconstruction: a possible method to optimize the collimation profile. Phys Med Biol 2015; 60:2403-19. [PMID: 25716556 DOI: 10.1088/0031-9155/60/6/2403] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
In SPECT imaging, improvement or deterioration of performance is mostly due to collimator design. Classical SPECT systems mainly use parallel hole or pinhole collimators. Rotating slat collimators (RSC) can be an interesting alternative to optimize the tradeoff between detection efficiency and spatial resolution. The present study was conducted using a RSC system for small animal imaging called CLiR. The CLiR system was used in planar mode only. In a previous study, planar 2D projections were reconstructed using the well-known filtered backprojection algorithm (FBP). In this paper, we investigated the use of the statistical reconstruction algorithm maximum likelihood expectation maximization (MLEM) to reconstruct 2D images with the CLiR system using a probability matrix calculated using an analytic approach. The primary objective was to propose a method to quickly generate a light system matrix, which facilitates its handling and storage, while providing accurate and reliable performance. Two other matrices were calculated using GATE Monte Carlo simulations to investigate the performance obtained using the matrix calculated analytically. The first matrix calculated using GATE took all the physics processes into account, where the second did not consider for the scattering, as the analytical matrix did not take this physics process into account either. 2D images were reconstructed using FBP and MLEM with the three different probability matrices. Both simulated and experimental data were used. A comparative study of these images was conducted using different metrics: the modulation transfert function, the signal-to-noise ratio and quantification measurement. All the results demonstrated the suitability of using a probability matrix calculated analytically. It provided similar results in terms of spatial resolution (about 0.6 mm with differences <5%), signal-to-noise ratio (differences <10%), or quality of image.
Collapse
Affiliation(s)
- F Boisson
- Institut Pluridisciplinaire Hubert Curien, Universit de Strasbourg, 23 rue du Loess, 67037 Strasbourg, France. CNRS, UMR7178, 67037 Strasbourg, France
| | | | | | | | | |
Collapse
|
5
|
Hutton BF, Buvat I, Beekman FJ. Review and current status of SPECT scatter correction. Phys Med Biol 2011; 56:R85-112. [PMID: 21701055 DOI: 10.1088/0031-9155/56/14/r01] [Citation(s) in RCA: 101] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
6
|
Gullberg GT, Reutter BW, Sitek A, Maltz JS, Budinger TF. Dynamic single photon emission computed tomography--basic principles and cardiac applications. Phys Med Biol 2010; 55:R111-91. [PMID: 20858925 PMCID: PMC3306016 DOI: 10.1088/0031-9155/55/20/r01] [Citation(s) in RCA: 90] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The very nature of nuclear medicine, the visual representation of injected radiopharmaceuticals, implies imaging of dynamic processes such as the uptake and wash-out of radiotracers from body organs. For years, nuclear medicine has been touted as the modality of choice for evaluating function in health and disease. This evaluation is greatly enhanced using single photon emission computed tomography (SPECT), which permits three-dimensional (3D) visualization of tracer distributions in the body. However, to fully realize the potential of the technique requires the imaging of in vivo dynamic processes of flow and metabolism. Tissue motion and deformation must also be addressed. Absolute quantification of these dynamic processes in the body has the potential to improve diagnosis. This paper presents a review of advancements toward the realization of the potential of dynamic SPECT imaging and a brief history of the development of the instrumentation. A major portion of the paper is devoted to the review of special data processing methods that have been developed for extracting kinetics from dynamic cardiac SPECT data acquired using rotating detector heads that move as radiopharmaceuticals exchange between biological compartments. Recent developments in multi-resolution spatiotemporal methods enable one to estimate kinetic parameters of compartment models of dynamic processes using data acquired from a single camera head with slow gantry rotation. The estimation of kinetic parameters directly from projection measurements improves bias and variance over the conventional method of first reconstructing 3D dynamic images, generating time-activity curves from selected regions of interest and then estimating the kinetic parameters from the generated time-activity curves. Although the potential applications of SPECT for imaging dynamic processes have not been fully realized in the clinic, it is hoped that this review illuminates the potential of SPECT for dynamic imaging, especially in light of new developments that enable measurement of dynamic processes directly from projection measurements.
Collapse
Affiliation(s)
- Grant T Gullberg
- E O Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA.
| | | | | | | | | |
Collapse
|
7
|
Abstract
Three-dimensional (3D) reconstruction of an object mass density from the set of its 2D line projections lies at a core of both single-particle reconstruction technique and electron tomography. Both techniques utilize electron microscope to collect a set of projections of either multiple objects representing in principle the same macromolecular complex in an isolated form, or a subcellular structure isolated in situ. Therefore, the goal of macromolecular electron microscopy is to invert the projection transformation to recover the distribution of the mass density of the original object. The problem is interesting in that in its discrete form it is ill-posed and not invertible. Various algorithms have been proposed to cope with the practical difficulties of this inversion problem and their differ widely in terms of their robustness with respect to noise in the data, completeness of the collected projection dataset, errors in projections orientation parameters, abilities to efficiently handle large datasets, and other obstacles typically encountered in molecular electron microscopy. Here, we review the theoretical foundations of 3D reconstruction from line projections followed by an overview of reconstruction algorithms routinely used in practice of electron microscopy.
Collapse
Affiliation(s)
- Pawel A Penczek
- Department of Biochemistry and Molecular Biology, The University of Texas, Houston Medical School, Houston, Texas, USA
| |
Collapse
|
8
|
Tohme MS, Qi J. Iterative image reconstruction for positron emission tomography based on a detector response function estimated from point source measurements. Phys Med Biol 2009; 54:3709-25. [PMID: 19478379 DOI: 10.1088/0031-9155/54/12/007] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The accuracy of the system model in an iterative reconstruction algorithm greatly affects the quality of reconstructed positron emission tomography (PET) images. For efficient computation in reconstruction, the system model in PET can be factored into a product of a geometric projection matrix and sinogram blurring matrix, where the former is often computed based on analytical calculation, and the latter is estimated using Monte Carlo simulations. Direct measurement of a sinogram blurring matrix is difficult in practice because of the requirement of a collimated source. In this work, we propose a method to estimate the 2D blurring kernels from uncollimated point source measurements. Since the resulting sinogram blurring matrix stems from actual measurements, it can take into account the physical effects in the photon detection process that are difficult or impossible to model in a Monte Carlo (MC) simulation, and hence provide a more accurate system model. Another advantage of the proposed method over MC simulation is that it can easily be applied to data that have undergone a transformation to reduce the data size (e.g., Fourier rebinning). Point source measurements were acquired with high count statistics in a relatively fine grid inside the microPET II scanner using a high-precision 2D motion stage. A monotonically convergent iterative algorithm has been derived to estimate the detector blurring matrix from the point source measurements. The algorithm takes advantage of the rotational symmetry of the PET scanner and explicitly models the detector block structure. The resulting sinogram blurring matrix is incorporated into a maximum a posteriori (MAP) image reconstruction algorithm. The proposed method has been validated using a 3 x 3 line phantom, an ultra-micro resolution phantom and a (22)Na point source superimposed on a warm background. The results of the proposed method show improvements in both resolution and contrast ratio when compared with the MAP reconstruction with a MC-based sinogram blurring matrix, and one without a detector response model. The reconstruction time is unaffected by the new method since the blurring component takes a relatively small part of the overall reconstruction time. The proposed method can be applied to other PET scanners for human and animal imaging.
Collapse
Affiliation(s)
- Michel S Tohme
- Department of Biomedical Engineering, University of California, Davis, CA 95616, USA
| | | |
Collapse
|
9
|
Seo Y, Mari C, Hasegawa BH. Technological development and advances in single-photon emission computed tomography/computed tomography. Semin Nucl Med 2008; 38:177-98. [PMID: 18396178 DOI: 10.1053/j.semnuclmed.2008.01.001] [Citation(s) in RCA: 139] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Single-photon emission computed tomography/computed tomography (SPECT/CT) has emerged during the past decade as a means of correlating anatomical information from CT with functional information from SPECT. The integration of SPECT and CT in a single imaging device facilitates anatomical localization of the radiopharmaceutical to differentiate physiological uptake from that associated with disease and patient-specific attenuation correction to improve the visual quality and quantitative accuracy of the SPECT image. The first clinically available SPECT/CT systems performed emission-transmission imaging using a dual-headed SPECT camera and a low-power x-ray CT subsystem. Newer SPECT/CT systems are available with high-power CT subsystems suitable for detailed anatomical diagnosis, including CT coronary angiography and coronary calcification that can be correlated with myocardial perfusion measurements. The high-performance CT capabilities also offer the potential to improve compensation of partial volume errors for more accurate quantitation of radionuclide measurement of myocardial blood flow and other physiological processes and for radiation dosimetry for radionuclide therapy. In addition, new SPECT technologies are being developed that significantly improve the detection efficiency and spatial resolution for radionuclide imaging of small organs including the heart, brain, and breast, and therefore may provide new capabilities for SPECT/CT imaging in these important clinical applications.
Collapse
Affiliation(s)
- Youngho Seo
- Department of Radiology, University of California, San Francisco, San Francisco, CA, USA
| | | | | |
Collapse
|
10
|
Liu RR, Erwin WD. Automatic estimation of detector radial position for contoured SPECT acquisition using CT images on a SPECT/CT system. Med Phys 2006; 33:2800-8. [PMID: 16964856 DOI: 10.1118/1.2219770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
An algorithm was developed to estimate noncircular orbit (NCO) single-photon emission computed tomography (SPECT) detector radius on a SPECT/CT imaging system using the CT images, for incorporation into collimator resolution modeling for iterative SPECT reconstruction. Simulated male abdominal (arms up), male head and neck (arms down) and female chest (arms down) anthropomorphic phantom, and ten patient, medium-energy SPECT/CT scans were acquired on a hybrid imaging system. The algorithm simulated inward SPECT detector radial motion and object contour detection at each projection angle, employing the calculated average CT image and a fixed Hounsfield unit (HU) threshold. Calculated radii were compared to the observed true radii, and optimal CT threshold values, corresponding to patient bed and clothing surfaces, were found to be between -970 and -950 HU. The algorithm was constrained by the 45 cm CT field-of-view (FOV), which limited the detected radii to < or = 22.5 cm and led to occasional radius underestimation in the case of object truncation by CT. Two methods incorporating the algorithm were implemented: physical model (PM) and best fit (BF). The PM method computed an offset that produced maximum overlap of calculated and true radii for the phantom scans, and applied that offset as a calculated-to-true radius transformation. For the BF method, the calculated-to-true radius transformation was based upon a linear regression between calculated and true radii. For the PM method, a fixed offset of +2.75 cm provided maximum calculated-to-true radius overlap for the phantom study, which accounted for the camera system's object contour detect sensor surface-to-detector face distance. For the BF method, a linear regression of true versus calculated radius from a reference patient scan was used as a calculated-to-true radius transform. Both methods were applied to ten patient scans. For -970 and -950 HU thresholds, the combined overall average root-mean-square (rms) error in radial position for eight patient scans without truncation were 3.37 cm (12.9%) for PM and 1.99 cm (8.6%) for BF, indicating BF is superior to PM in the absence of truncation. For two patient scans with truncation, the rms error was 3.24 cm (12.2%) for PM and 4.10 cm (18.2%) for BF. The slightly better performance of PM in the case of truncation is anomalous, due to FOV edge truncation artifacts in the CT reconstruction, and thus is suspect. The calculated NCO contour for a patient SPECT/CT scan was used with an iterative reconstruction algorithm that incorporated compensation for system resolution. The resulting image was qualitatively superior to the image obtained by reconstructing the data using the fixed radius stored by the scanner. The result was also superior to the image reconstructed using the iterative algorithm provided with the system, which does not incorporate resolution modeling. These results suggest that, under conditions of no or only mild lateral truncation of the CT scan, the algorithm is capable of providing radius estimates suitable for iterative SPECT reconstruction collimator geometric resolution modeling.
Collapse
Affiliation(s)
- Ruijie Rachel Liu
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77230, USA
| | | |
Collapse
|
11
|
Abstract
In emission tomography statistically based iterative methods can improve image quality relative to analytic image reconstruction through more accurate physical and statistical modelling of high-energy photon production and detection processes. Continued exponential improvements in computing power, coupled with the development of fast algorithms, have made routine use of iterative techniques practical, resulting in their increasing popularity in both clinical and research environments. Here we review recent progress in developing statistically based iterative techniques for emission computed tomography. We describe the different formulations of the emission image reconstruction problem and their properties. We then describe the numerical algorithms that are used for optimizing these functions and illustrate their behaviour using small scale simulations.
Collapse
Affiliation(s)
- Jinyi Qi
- Department of Biomedical Engineering, University of California, Davis, CA 95616, USA
| | | |
Collapse
|
12
|
Abstract
Statistically based iterative image reconstruction methods have been developed for emission tomography. One important component in iterative image reconstruction is the system matrix, which defines the mapping from the image space to the data space. Several groups have demonstrated that an accurate system matrix can improve image quality in both single photon emission computed tomography (SPECT) and positron emission tomography (PET). While iterative methods are amenable to arbitrary and complicated system models, the true system response is never known exactly. In practice, one also has to sacrifice the accuracy of the system model because of limited computing and imaging resources. This paper analyses the effect of errors in the system matrix on iterative image reconstruction methods that are based on the maximum a posteriori principle. We derived an analytical expression for calculating artefacts in a reconstructed image that are caused by errors in the system matrix using the first-order Taylor series approximation. The theoretical expression is used to determine the required minimum accuracy of the system matrix in emission tomography. Computer simulations show that the theoretical results work reasonably well in low-noise situations.
Collapse
Affiliation(s)
- Jinyi Qi
- Department of Biomedical Engineering, University of California, Davis, CA 95616, USA.
| | | |
Collapse
|
13
|
Qi J. Analysis of lesion detectability in Bayesian emission reconstruction with nonstationary object variability. IEEE TRANSACTIONS ON MEDICAL IMAGING 2004; 23:321-329. [PMID: 15027525 DOI: 10.1109/tmi.2004.824239] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Bayesian methods based on the maximum a posteriori principle (also called penalized maximum-likelihood methods) have been developed to improve image quality in emission tomography. To explore the full potential of Bayesian reconstruction for lesion detection, we derive simplified theoretical expressions that allow fast evaluation of the detectability of a lesion in Bayesian reconstruction. This work is builded on the recent progress on the theoretical analysis of image properties of statistical reconstructions and the development of numerical observers. We explicitly model the nonstationary variation of the lesion and background without assuming that they are locally stationary. The results can be used to choose the optimum prior parameters for the maximum lesion detectability. The theoretical results are validated using Monte Carlo simulations. The comparisons show good agreement between the theoretical predictions and the Monte Carlo results. We also demonstrate that the lesion detectability can be reliably estimated using one noisy data set.
Collapse
Affiliation(s)
- Jinyi Qi
- Department of Nuclear Medicine and Functional Imaging, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA.
| |
Collapse
|