Karger CP, Elter A, Dorsch S, Mann P, Pappas E, Oldham M. Validation of complex radiotherapy techniques using polymer gel dosimetry. Phys Med Biol 2024; 69:06TR01. [PMID: 38330494 DOI: 10.1088/1361-6560/ad278f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Accepted: 02/08/2024] [Indexed: 02/10/2024]
Abstract
Modern radiotherapy delivers highly conformal dose distributions to irregularly shaped target volumes while sparing the surrounding normal tissue. Due to the complex planning and delivery techniques, dose verification and validation of the whole treatment workflow by end-to-end tests became much more important and polymer gel dosimeters are one of the few possibilities to capture the delivered dose distribution in 3D. The basic principles and formulations of gel dosimetry and its evaluation methods are described and the available studies validating device-specific geometrical parameters as well as the dose delivery by advanced radiotherapy techniques, such as 3D-CRT/IMRT and stereotactic radiosurgery treatments, the treatment of moving targets, online-adaptive magnetic resonance-guided radiotherapy as well as proton and ion beam treatments, are reviewed. The present status and limitations as well as future challenges of polymer gel dosimetry for the validation of complex radiotherapy techniques are discussed.
Collapse
Affiliation(s)
- Christian P Karger
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
| | - Alina Elter
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
- Department of Radiation Oncology, University Hospital Heidelberg, Im Neuenheimer Feld 400, D-69120 Heidelberg, Germany
| | - Stefan Dorsch
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
| | - Philipp Mann
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
| | - Evangelos Pappas
- Radiology & Radiotherapy Sector, Department of Biomedical Sciences, University of West Attica, Athens, Greece
| | - Mark Oldham
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, United States of America
| |
Collapse
|
2
|
De Deene Y. Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D. Gels 2022; 8:599. [PMID: 36135311 PMCID: PMC9498652 DOI: 10.3390/gels8090599] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 09/07/2022] [Accepted: 09/10/2022] [Indexed: 12/22/2022] Open
Abstract
Gel dosimetry was developed in the 1990s in response to a growing need for methods to validate the radiation dose distribution delivered to cancer patients receiving high-precision radiotherapy. Three different classes of gel dosimeters were developed and extensively studied. The first class of gel dosimeters is the Fricke gel dosimeters, which consist of a hydrogel with dissolved ferrous ions that oxidize upon exposure to ionizing radiation. The oxidation results in a change in the nuclear magnetic resonance (NMR) relaxation, which makes it possible to read out Fricke gel dosimeters by use of quantitative magnetic resonance imaging (MRI). The radiation-induced oxidation in Fricke gel dosimeters can also be visualized by adding an indicator such as xylenol orange. The second class of gel dosimeters is the radiochromic gel dosimeters, which also exhibit a color change upon irradiation but do not use a metal ion. These radiochromic gel dosimeters do not demonstrate a significant radiation-induced change in NMR properties. The third class is the polymer gel dosimeters, which contain vinyl monomers that polymerize upon irradiation. Polymer gel dosimeters are predominantly read out by quantitative MRI or X-ray CT. The accuracy of the dosimeters depends on both the physico-chemical properties of the gel dosimeters and on the readout technique. Many different gel formulations have been proposed and discussed in the scientific literature in the last three decades, and scanning methods have been optimized to achieve an acceptable accuracy for clinical dosimetry. More recently, with the introduction of the MR-Linac, which combines an MRI-scanner and a clinical linear accelerator in one, it was shown possible to acquire dose maps during radiation, but new challenges arise.
Collapse
Affiliation(s)
- Yves De Deene
- Liverpool & Macarthur Cancer Therapy Centres, Liverpool, NSW 1871, Australia; or
- Ingham Institute, Liverpool, NSW 2170, Australia
- School of Science, Western Sydney University, Penrith, NSW 2751, Australia
| |
Collapse
|
3
|
Takatsu Y, Yamamura K, Yamatani Y, Takahashi D, Yoshida R, Asahara M, Honda M, Miyati T. Echo-planar imaging is superior to fast spin-echo diffusion-weighted imaging for cranioplasty using titanium mesh in brain magnetic resonance imaging: a phantom study. Radiol Phys Technol 2021; 15:89-99. [PMID: 34855114 DOI: 10.1007/s12194-021-00646-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2020] [Revised: 11/21/2021] [Accepted: 11/22/2021] [Indexed: 12/01/2022]
Abstract
This study aimed to compare the radiofrequency (RF) shielding effects of titanium mesh of echo-planar imaging (EPI) versus fast spin-echo (FSE) diffusion-weighted imaging (DWI) to establish a suitable sequence for patients who undergo cranioplasty and for whom titanium mesh was used in brain magnetic resonance imaging (MRI). A 1.5-T MRI scanner with clinical setting sequences was used. A phantom for the examination constructed using a sucrose solution in a plastic container was used to compare the signal attenuation (SA) ratio, area of RF shielding effect (Area), normalized absolute average deviation (NAAD), and apparent diffusion coefficient (ADC) between EPI and FSE-DWI. EPI provided significantly better SA ratio, Area, and NAAD (P < 0.01). When the number of slices increased, the RF shielding became more negative. There was no significant difference in the ADC. Regardless of the k-trajectory, EPI-DWI had a lower RF shielding effect than FSE-DWI in patients undergoing cranioplasty.
Collapse
Affiliation(s)
- Yasuo Takatsu
- Department of System Control Engineering, Graduate School of Engineering, Tokushima Bunri University, 1314-1 Shido, Sanuki-City, Kagawa, 769-2193, Japan. .,Department of Radiological Technology, Faculty of Health and Welfare, Tokushima Bunri University, 1314-1 Shido, Sanuki-City, Kagawa, 769-2193, Japan. .,Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, 920-0942, Japan.
| | - Kenichiro Yamamura
- Department of Radiological Technology, Faculty of Health and Welfare, Tokushima Bunri University, 1314-1 Shido, Sanuki-City, Kagawa, 769-2193, Japan
| | - Yuya Yamatani
- Division of Central Radiology, Nara Medical University Hospital, 840, Shijo-cho, Kashihara, Nara, 634-8522, Japan
| | - Daisuke Takahashi
- Department of Radiological Technology, Iwate Prefectural Central Hospital, 4-1, 1 Cho-me, Ueda, Morioka City, Iwate, 020-0066, Japan
| | - Rei Yoshida
- Department of Radiology, Kurihara Central Hospital, 3-3-1 Miyano cyuou, Tsukidate, Kurihara-City, Miyagi, 987-2205, Japan
| | - Masaki Asahara
- Department of Radiological Technology, Faculty of Health and Welfare, Tokushima Bunri University, 1314-1 Shido, Sanuki-City, Kagawa, 769-2193, Japan
| | - Michitaka Honda
- Department of Radiological Technology, Faculty of Health and Welfare, Tokushima Bunri University, 1314-1 Shido, Sanuki-City, Kagawa, 769-2193, Japan
| | - Tosiaki Miyati
- Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, 920-0942, Japan
| |
Collapse
|
4
|
Maras P, Jaszczak M, Kozicki M. Basic features of VIC-T dosimeter with spiral CT readout, CT scanning conditions and data processing with a new polyGeVero-CT software package. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109730] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
5
|
Takatsu Y, Yoshida R, Yamamura K, Yamatani Y, Ueyama T, Kimura T, Nohara Y, Sahara T, Nishiyama K, Miyati T. Three-dimensional Gradient-echo is Effective in Suppressing Radiofrequency Shielding by a Titanium Mesh. Magn Reson Med Sci 2021; 20:182-189. [PMID: 32595187 PMCID: PMC8203480 DOI: 10.2463/mrms.mp.2019-0180] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Accepted: 04/24/2020] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To determine which sequence for frequently used general contrast-enhanced brain MRI shows the least radiofrequency shielding effect of a titanium mesh in cranioplasty using a phantom. METHODS A 1.5T MRI scanner was used. Frequently used general 2D and 3D spin-echo sequences (SE) and T1 spoiled gradient echo sequences (GRE) used for MRI in clinical settings were adopted in this study. A titanium mesh was placed above a cubic phantom containing manganese chloride tetrahydrate and sodium chloride. The signal attenuation ratio and normalized absolute average deviation (NAAD) were calculated. Moreover, the flip angle (FA) dependency in SE and area of excitation dependency in 3D sequences were analyzed using NAAD. RESULTS The signal attenuation ratio at the position nearest to the titanium mesh for 2D SE was 71.8% larger than that at the position nearest to the titanium mesh for 3D GRE. With regard to NAAD, 3D GRE showed the highest values among the sequences. When FA was increased, radiofrequency shielding effect was improved. There were no significant differences between the narrow and wide area of excitation. 3D GRE showed the least radiofrequency shielding effect, and it was considered as the optimal sequence for MRI in the presence of a titanium mesh. CONCLUSION 3D GRE shows the least radiofrequency shielding effect of a titanium mesh after cranioplasty among frequently used general sequences for contrast-enhanced brain MRI.
Collapse
Affiliation(s)
- Yasuo Takatsu
- Department of Radiological Technology, Faculty of Health and Welfare, Tokushima Bunri University, Kagawa, Japan
- Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, Ishikawa, Japan
| | - Rei Yoshida
- Department of Radiology, Kurihara Central Hospital, Miyagi, Japan
| | | | - Yuya Yamatani
- Division of Central Radiology, Nara Medical University Hospital, Nara, Japan
| | - Tsuyoshi Ueyama
- Department of Radiology, The University of Tokyo Hospital, Tokyo, Japan
| | - Tetsuya Kimura
- Department of Radiological Technology, Sakai City Medical Center, Osaka, Japan
| | - Yuriko Nohara
- Department of Radiology, Daini Osaka Police Hospital, Osaka, Japan
| | - Tomohiro Sahara
- Division of Radiological Technology, Osaka City University Hospital, Osaka, Japan
| | - Kengo Nishiyama
- Department of Radiology, Osaka Red Cross Hospital, Osaka, Japan
| | - Tosiaki Miyati
- Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, Ishikawa, Japan
| |
Collapse
|
6
|
Danneels L, Cagnie B, D'hooge R, De Deene Y, Crombez G, Vanderstraeten G, Parlevliet T, Van Oosterwijck J. The effect of experimental low back pain on lumbar muscle activity in people with a history of clinical low back pain: a muscle functional MRI study. J Neurophysiol 2016; 115:851-7. [DOI: 10.1152/jn.00192.2015] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2015] [Accepted: 11/27/2015] [Indexed: 11/22/2022] Open
Abstract
In people with a history of low back pain (LBP), structural and functional alterations have been observed at several peripheral and central levels of the sensorimotor pathway. These existing alterations might interact with the way the sensorimotor system responds to pain. We examined this assumption by evaluating the lumbar motor responses to experimental nociceptive input of 15 participants during remission of unilateral recurrent LBP. Quantitative T2 images (muscle functional MRI) were taken bilaterally of multifidus, erector spinae, and psoas at several segmental levels (L3 upper and L4 upper and lower endplate) and during several conditions: 1) at rest, 2) upon trunk-extension exercise without pain, and 3) upon trunk-extension exercise with experimental induced pain at the clinical pain-side (1.5-ml intramuscular hypertonic saline injections in erector spinae). Following experimental pain induction, muscle activity levels similarly reduced for all three muscles, on both painful and nonpainful sides, and at multiple segmental levels ( P = 0.038). Pain intensity and localization from experimental LBP were similar as during recalled clinical LBP episodes. In conclusion, unilateral and unisegmental experimental LBP exerts a generalized and widespread decrease in lumbar muscle activity during remission of recurrent LBP. This muscle response is consistent with previous observed patterns in healthy people subjected to the same experimental pain paradigm. It is striking that similar inhibitory patterns in response to pain could be observed, despite the presence of preexisting alterations in the lumbar musculature during remission of recurrent LBP. These results suggest that motor output can modify along the course of recurrent LBP.
Collapse
Affiliation(s)
- Lieven Danneels
- Department of Rehabilitation Sciences and Physiotherapy, Ghent University, Ghent, Belgium
| | - Barbara Cagnie
- Department of Rehabilitation Sciences and Physiotherapy, Ghent University, Ghent, Belgium
| | - Roseline D'hooge
- Department of Rehabilitation Sciences and Physiotherapy, Ghent University, Ghent, Belgium
| | - Yves De Deene
- Department of Radiotherapy and Experimental Cancer Research, Ghent University Hospital, Ghent, Belgium
| | - Geert Crombez
- Department of Experimental Clinical and Health Psychology, Ghent University, Ghent, Belgium
| | - Guy Vanderstraeten
- Department of Rehabilitation Sciences and Physiotherapy, Ghent University, Ghent, Belgium
- Department of Physical and Rehabilitation Medicine, Ghent University Hospital, Ghent, Belgium; and
| | - Thierry Parlevliet
- Department of Physical Medicine and Orthopedic Surgery, Ghent University Hospital, Ghent, Belgium
| | | |
Collapse
|
7
|
Role of gel dosimeters in boron neutron capture therapy. Appl Radiat Isot 2015; 103:72-81. [PMID: 26070173 DOI: 10.1016/j.apradiso.2015.05.017] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2014] [Revised: 02/10/2015] [Accepted: 05/26/2015] [Indexed: 12/27/2022]
Abstract
Gel dosimeters have acquired a unique status in radiotherapy, especially with the advent of the new techniques in which there is a need for three-dimensional dose measurement with high spatial resolution. One of the techniques in which the use of gel dosimeters has drawn the attention of the researchers is the boron neutron capture therapy. Exploring the history of gel dosimeters, this paper sets out to study their role in the boron neutron capture therapy dosimetric process.
Collapse
|
8
|
|
9
|
Reduced dose uncertainty in MRI-based polymer gel dosimetry using parallel RF transmission with multiple RF sources. J Radioanal Nucl Chem 2014. [DOI: 10.1007/s10967-014-3232-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
10
|
Lumbar muscle dysfunction during remission of unilateral recurrent nonspecific low-back pain: evaluation with muscle functional MRI. Clin J Pain 2013; 29:187-94. [PMID: 23369927 DOI: 10.1097/ajp.0b013e31824ed170] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES After cessation of a low-back pain (LBP) episode, alterations in trunk muscle behavior, despite recovery from pain, have been hypothesized to play a pathogenic role in the recurrence of LBP. This study aimed to identify the presence of lumbar muscle dysfunction during the remission of recurrent LBP, while performing a low-load trunk-extension movement. METHODS Thirteen participants with unilateral recurrent LBP were tested at least 1 month after cessation of the previous LBP episode and were compared with a healthy control group without any history of LBP (n=13). Also, differences between previously painful and nonpainful sides were examined. Muscle functional magnetic resonance imaging, based on quantitative T2-imaging, was used to examine muscle tissue characteristics (T2 rest) and muscle recruitment (T2 shift) during prone trunk extension. The lumbar multifidus, erector spinae, quadratus lumborum, and psoas were bilaterally visualized on 2 lumbar levels using a T2-weighted (spin-echo multicontrast) magnetic resonance imaging sequence. RESULTS Linear mixed model analysis revealed a significantly lower T2 rest (P=0.044) and a significantly higher T2 shift (P=0.034) solely for the multifidus in the LBP group compared with the control group. No significant differences between pain sides were found. DISCUSSION Lower T2-rest values have been suggested to correlate with a conversion of the multifidus' fiber typing toward the glycolytic muscle spectrum. Elevated T2 shifts correspond with increased levels of metabolic activity in the multifidus in the LBP group, for which several hypotheses can be put forward. Taken together, these findings provide evidence of concurrent alterations in the multifidus structure and activity in individuals with unilateral recurrent LBP, despite being pain free and functionally recovered.
Collapse
|
11
|
|
12
|
|
13
|
Vandecasteele J, De Deene Y. On the validity of 3D polymer gel dosimetry: III. MRI-related error sources. Phys Med Biol 2012; 58:63-85. [DOI: 10.1088/0031-9155/58/1/63] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
14
|
Vandecasteele J, De Deene Y. On the validity of 3D polymer gel dosimetry: I. Reproducibility study. Phys Med Biol 2012; 58:19-42. [DOI: 10.1088/0031-9155/58/1/19] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|
15
|
Sedaghat M, Bujold R, Lepage M. Investigating potential physicochemical errors in polymer gel dosimeters. Phys Med Biol 2011; 56:6083-107. [DOI: 10.1088/0031-9155/56/18/019] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
16
|
De Geeter N, Crevecoeur G, Dupré L. Low-parametric induced current - magnetic resonance electrical impedance tomography for quantitative conductivity estimation of brain tissues using a priori information: a simulation study. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2011; 2010:5669-72. [PMID: 21097314 DOI: 10.1109/iembs.2010.5627896] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Accurate estimation of the human head conductivity is important for the diagnosis and therapy of brain diseases. Induced Current - Magnetic Resonance Electrical Impedance Tomography (IC-MREIT) is a recently developed non-invasive technique for conductivity estimation. This paper presents a formulation where a low number of material parameters need to be estimated, starting from MR eddy-current field maps. We use a parameterized frequency dependent 4-Cole-Cole material model, an efficient independent impedance method for eddy-current calculations and a priori information through the use of voxel models. The proposed procedure circumvents the ill-posedness of traditional IC-MREIT and computational efficiency is obtained by using an efficient forward eddy-current solver.
Collapse
Affiliation(s)
- Nele De Geeter
- Department of Electrical Energy, Systems and Automation, Ghent University, 9000, Belgium.
| | | | | |
Collapse
|
17
|
Low DA, Moran JM, Dempsey JF, Dong L, Oldham M. Dosimetry tools and techniques for IMRT. Med Phys 2011; 38:1313-38. [DOI: 10.1118/1.3514120] [Citation(s) in RCA: 298] [Impact Index Per Article: 22.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
|
18
|
|
19
|
Baldock C, De Deene Y, Doran S, Ibbott G, Jirasek A, Lepage M, McAuley KB, Oldham M, Schreiner LJ. Polymer gel dosimetry. Phys Med Biol 2010. [PMID: 20150687 DOI: 10.1088/0031‐9155/55/5/r01] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented.
Collapse
Affiliation(s)
- C Baldock
- Institute of Medical Physics, School of Physics, University of Sydney, Australia.
| | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Baldock C, De Deene Y, Doran S, Ibbott G, Jirasek A, Lepage M, McAuley KB, Oldham M, Schreiner LJ. Polymer gel dosimetry. Phys Med Biol 2010; 55:R1-63. [PMID: 20150687 DOI: 10.1088/0031-9155/55/5/r01] [Citation(s) in RCA: 450] [Impact Index Per Article: 32.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented.
Collapse
Affiliation(s)
- C Baldock
- Institute of Medical Physics, School of Physics, University of Sydney, Australia.
| | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Moutsatsos A, Petrokokkinos L, Karaiskos P, Papagiannis P, Georgiou E, Dardoufas K, Sandilos P, Torrens M, Pantelis E, Kantemiris I, Sakelliou L, Seimenis I. Gamma Knife output factor measurements using VIP polymer gel dosimetry. Med Phys 2009; 36:4277-87. [DOI: 10.1118/1.3183500] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
22
|
|
23
|
Wong C, Ackerly T, He C, Patterson W, Powell C, Qiao G, Solomon D, Meder R, Geso M. Small field size dose-profile measurements using gel dosimeters, gafchromic films and micro-thermoluminescent dosimeters. RADIAT MEAS 2009. [DOI: 10.1016/j.radmeas.2009.03.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
24
|
|
25
|
Archambault L, Leclerc G, Beaulieu L, Lepage M. Absolute calibration of polymer gel dosimeters using scintillating fibers. ACTA ACUST UNITED AC 2007. [DOI: 10.1088/1742-6596/56/1/039] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
26
|
Brindha S, Kumar V, Vasanth S, Ravindran Paul B. Adaptation of radiation field analyser (RFA) as optical CT scanner for gel dosimetry. J Med Phys 2006; 31:22-7. [PMID: 21206636 PMCID: PMC3003890 DOI: 10.4103/0971-6203.25666] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2006] [Accepted: 03/20/2006] [Indexed: 11/17/2022] Open
Abstract
Optical scanning is one of the emerging evaluation tools used for obtaining dose distributions in gel dosimetry. A radiation field analyzer adapted into an optical CT scanner to evaluate an irradiated Fricke gel has been already reported by others. This prototype optical CT scanner functions like a first generation x-ray CT scanner in the translate-rotate fashion. A similar scanner was constructed in our department for optical scanning of irradiated FX gel. At first, an aquarium was constructed and fitted into the water phantom of the RFA with provision to place the gel phantom to be scanned along with a light source and detector. The movements of the RFA were utilized to scan the gel phantom. A scan of a cuvette filled with colored solution was carried out and the resulting images were reconstructed and profiles obtained to evaluate the working of the optical scanner. A scan of the gel phantom was then obtained to evaluate the performance of the scanner. Thus a radiation field analyzer (DYNASCAN) was successfully adapted to an optical scanner to evaluate Fricke gels in our department.
Collapse
Affiliation(s)
- S Brindha
- Department of Radiotherapy, Christian Medical College, Vellore, Tamilnadu, India
| | | | | | | |
Collapse
|
27
|
Hilts M, Jirasek A, Duzenli C. Technical considerations for implementation of x-ray CT polymer gel dosimetry. Phys Med Biol 2005; 50:1727-45. [PMID: 15815093 DOI: 10.1088/0031-9155/50/8/008] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Gel dosimetry is the most promising 3D dosimetry technique in current radiation therapy practice. X-ray CT has been shown to be a feasible method of reading out polymer gel dosimeters and, with the high accessibility of CT scanners to cancer hospitals, presents an exciting possibility for clinical implementation of gel dosimetry. In this study we report on technical considerations for implementation of x-ray CT polymer gel dosimetry. Specifically phantom design, CT imaging methods, imaging time requirements and gel dose response are investigated. Where possible, recommendations are made for optimizing parameters to enhance system performance. The dose resolution achievable with an optimized system is calculated given voxel size and imaging time constraints. Results are compared with MRI and optical CT polymer gel dosimetry results available in the literature.
Collapse
Affiliation(s)
- M Hilts
- Medical Physics, BC Cancer Agency-Vancouver Island Centre, Victoria, Canada.
| | | | | |
Collapse
|
28
|
Hilts M, Jirasek A, Duzenli C. Effects of gel composition on the radiation induced density change in PAG polymer gel dosimeters: a model and experimental investigations. Phys Med Biol 2005; 49:2477-90. [PMID: 15272668 DOI: 10.1088/0031-9155/49/12/001] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Due to a density change that occurs in irradiated polyacrylamide gel (PAG), x-ray computed tomography (CT) has emerged as a feasible method of performing polymer gel dosimetry. However, applicability of the technique is currently limited by low sensitivity of the density change to dose. This work investigates the effect of PAG composition on the radiation induced density change and provides direction for future work in improving the sensitivity of CT polymer gel dosimetry. A model is developed that describes the PAG density change (delta(rho)gel) as a function of both polymer yield (%P) and an intrinsic density change, per unit polymer yield, that occurs on conversion of monomer to polymer (delta(rho)polymer). %P is a function of the fraction of monomer consumed and the weight fraction of monomer in the unirradiated gel (%T). Applying the model to experimental CT and Raman spectroscopic data, two important fundamental properties of the response of PAG density to dose (delta(rho)gel dose response) are discovered. The first property is that delta(rho)polymer)depends on PAG %C (cross-linking fraction of total monomer) such that low and high %C PAGs exhibit a higher deltarho(polymer)than do more intermediate %C PAGs. This relationship is opposite to the relationship of polymer yield to %C and is explained by the effect of %C on the type of polymer formed. The second property is that the delta(rho)gel dose response is linearly dependent on %T. From the model, the inference is that, at least for %T < or = 2%, monomer consumption and delta(rho)polymer depend solely on %C. In terms of optimizing CT polymer gel dosimetry for high sensitivity, these results indicate that delta(rho)polymer can be expected to vary with each polymer gel system and thus should be considered when choosing a polymer gel for CT gel dosimetry. However, delta(rho)polymerand %P cannot be maximized simultaneously and maximizing %P, by choosing gels with intermediate %C and high %T, is found to have the greatest impact on increasing the sensitivity of PAG density to dose. As such, future research into new gel formulations for high sensitivity CT polymer gel dosimetry should focus on gels that exhibit an intrinsic density change and maximizing polymer yield in these systems.
Collapse
Affiliation(s)
- M Hilts
- Medical Physics, BC Cancer Agency-Vancouver Centre, Vancouver, BC V6R 2B6, Canada.
| | | | | |
Collapse
|
29
|
Watanabe Y, Mooij R, Perera GM, Maryanski MJ. Heterogeneity phantoms for visualization of 3D dose distributions by MRI-based polymer gel dosimetry. Med Phys 2004; 31:975-84. [PMID: 15191281 DOI: 10.1118/1.1688210] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
Heterogeneity corrections in dose calculations are necessary for radiation therapy treatment plans. Dosimetric measurements of the heterogeneity effects are hampered if the detectors are large and their radiological characteristics are not equivalent to water. Gel dosimetry can solve these problems. Furthermore, it provides three-dimensional (3D) dose distributions. We used a cylindrical phantom filled with BANG-3 polymer gel to measure 3D dose distributions in heterogeneous media. The phantom has a cavity, in which water-equivalent or bone-like solid blocks can be inserted. The irradiated phantom was scanned with an magnetic resonance imaging (MRI) scanner. Dose distributions were obtained by calibrating the polymer gel for a relationship between the absorbed dose and the spin-spin relaxation rate of the magnetic resistance (MR) signal. To study dose distributions we had to analyze MR imaging artifacts. This was done in three ways: comparison of a measured dose distribution in a simulated homogeneous phantom with a reference dose distribution, comparison of a sagittally scanned image with a sagittal image reconstructed from axially scanned data, and coregistration of MR and computed-tomography images. We found that the MRI artifacts cause a geometrical distortion of less than 2 mm and less than 10% change in the dose around solid inserts. With these limitations in mind we could make some qualitative measurements. Particularly we observed clear differences between the measured dose distributions around an air-gap and around bone-like material for a 6 MV photon beam. In conclusion, the gel dosimetry has the potential to qualitatively characterize the dose distributions near heterogeneities in 3D.
Collapse
Affiliation(s)
- Yoichi Watanabe
- Department of Radiation Oncology, College of Physicians and Surgeons, Columbia University, 622 West 168th Street, New York, New York 10032, USA.
| | | | | | | |
Collapse
|
30
|
|
31
|
Baldock C. X-ray computer tomography, ultrasound and vibrational spectroscopic evaluation techniques of polymer gel dosimeters. ACTA ACUST UNITED AC 2004. [DOI: 10.1088/1742-6596/3/1/012] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
32
|
Hurley C, De Deene Y, Meder R, Pope JM, Baldock C. The effect of water molecular self-diffusion on quantitative high-resolution MRI polymer gel dosimetry. Phys Med Biol 2004; 48:3043-58. [PMID: 14529209 DOI: 10.1088/0031-9155/48/18/306] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
In polymer gel dosimetry, magnetic resonance imaging (MRI) is used to determine the spin-spin relaxation rate (R2) which in turn can be correlated with absorbed dose to provide a map of the spatial distribution of the absorbed dose in the irradiated dosimeter. High accuracy, precision and reproducibility of these dose maps are essential. Moreover, for dose verification around brachytherapy sources used for intravascular brachytherapy, a high spatial resolution is required (typically 0.01-0.1 mm). To achieve these microscopic resolutions, strong imaging gradients are applied. The Brownian motion of water molecules in the presence of these strong magnetic field gradients causes an attenuation of the MR signal. When using a multiple spin-echo sequence, this may result in a significant deviation in the measured R2. The diffusion-related change in R2 at high resolutions was investigated experimentally and correlated with predictions that were obtained numerically and algebraically. Diffusion weighting is determined by the self-diffusion coefficient D, and imaging parameters, quantified by the b-factor. The b-factor was calculated for a multiple spin-echo sequence for different gradient strengths and gradient pulse durations. The variations in R2 that were observed when changing the matrix size and slice thickness are explained. It is shown that a linear correlation between the matrix size and the variation in R2 is based on the diffusion weighting caused by the read-out gradients and slice selective gradients. In conclusion, the essence of taking into account molecular self-diffusion to quantify variations in the measured dose-R2 response when using high-resolution MRI in polymer gel dosimetry is emphasized.
Collapse
Affiliation(s)
- C Hurley
- School of Physical and Chemical Sciences, Queensland University of Technology, Brisbane, Queensland 4001, Australia
| | | | | | | | | |
Collapse
|
33
|
Mather ML, Baldock C. Ultrasound tomography imaging of radiation dose distributions in polymer gel dosimeters: preliminary study. Med Phys 2003; 30:2140-8. [PMID: 12945979 DOI: 10.1118/1.1590751] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
A novel imaging system for investigation of absorbed dose distributions in radiotherapy polymer gel dosimeters using ultrasound is introduced. A prototype transmission ultrasound computed tomography (UCT) imaging system is developed and evaluated. The imaging capabilities of the system are assessed through investigation of an irradiated polyacrylamide gel test phantom. Images based on transmitted signal amplitude and time of flight (TOF) of the ultrasonic signal through the phantom are reconstructed using a filtered backprojection technique. In general, the reconstruction of the square field in the TOF image was superior to the transmission image, however, transmission images displayed superior contrast to TOF images. The image quality achieved with this prototype system is promising and could be significantly enhanced through improvements, in particular through the development of more sophisticated experimental equipment. It is concluded that UCT is a viable technique for imaging absorbed dose distributions in polymer gel dosimeters and investigations are continuing to further improve the system.
Collapse
Affiliation(s)
- Melissa L Mather
- Centre for Medical, Health and Environmental Physics, Queensland University of Technology, Brisbane, Australia
| | | |
Collapse
|
34
|
Islam KTS, Dempsey JF, Ranade MK, Maryanski MJ, Low DA. Initial evaluation of commercial optical CT-based 3D gel dosimeter. Med Phys 2003; 30:2159-68. [PMID: 12945982 DOI: 10.1118/1.1593636] [Citation(s) in RCA: 60] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
We evaluated the OCTOPUS-ONE research laser CT scanner developed and manufactured by MGS Research, Inc. (Madison, CT). The scanner is designed for imaging 3D optical density distributions in BANG gels. The scanner operates in a translate-rotate configuration with a single scanning laser beam. The rotating cylindrical gel phantom is immersed in a refractive index matching solution and positioned at the center of a square tank made of plastic and glass. A stationary polarized He-Ne laser beam (633 nm) is reflected from a mirror moving parallel to the tank wall and scans the gel. Another mirror moves synchronously along the opposite side of the tank and collects the transmitted light and sends it to a single stationary silicon photodetector. A filtered backprojection algorithm is used to reconstruct projection data in a plane. The laser-mirrors-detector assembly is mounted on a horizontal platform that moves vertically for slice selection. We have tested the mechanical and optical setup, projection centering on the axis of rotation, linearity, and spatial resolution. We found the optical detector to respond linearly to transmitted light from control samples. The spatial resolution of the scanner was determined by employing a split field resolution technique. We obtained the horizontal and vertical full widths at half maxima of the laser beam intensity profiles as 0.6 and 0.8 mm, respectively. Dose calibration tests of the gel were performed using a nine-field (2 x 2 cm2 each) dose pattern irradiated at different dose levels. Finally, we compared gel-derived 2D planar dose distribution against radiochromic film measured dose distribution for both the nine-field and a uniform 5 x 5 cm2 field of 6 MV x rays. Very similar dose distributions were observed in gel and radiochromic film except in regions of steep dose gradient and highest dose. A dose normalization of 15.6% was required between the two dosimeters due to differences in overall radiation response. After normalization, analysis using the gamma evaluation showed that the radiochromic film and gel-measured dose distributions differed by a maximum gamma of 1.3 using 5% and 1.5 mm dose difference and distance-to-agreement criteria. The optical CT scanner has great potential as a 3D dosimeter, but a few refinements and further testing are necessary before its routine clinical use.
Collapse
Affiliation(s)
- K T S Islam
- Department of Radiation Oncology, Mallinckrodt Institute, Washington University School of Medicine, St. Louis, Missouri 63110, USA
| | | | | | | | | |
Collapse
|
35
|
Oldham M, Siewerdsen JH, Kumar S, Wong J, Jaffray DA. Optical-CT gel-dosimetry I: basic investigations. Med Phys 2003; 30:623-34. [PMID: 12722814 PMCID: PMC1616153 DOI: 10.1118/1.1559835] [Citation(s) in RCA: 103] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Comprehensive verification of the intricate dose distributions associated with advanced radiation treatments is now an immediate and substantial problem. The task is challenging using traditional dosimeters because of restrictions to point measurements (ion chambers, diodes, TLD, etc.) or planar measurements (film). In essence, rapid advances in the technology to deliver radiation treatments have not been paralleled by corresponding advances in the ability to verify these treatments. A potential solution has emerged in the form of water equivalent three dimensional (3D) gel-dosimetry. In this paper we present basic characterization and performance studies of a prototype optical-CT scanning system developed in our laboratory. An analysis of the potential role or scope of gel dosimetry, in relation to other dosimeters, and to verification across the spectrum of therapeutic techniques is also given. The characterization studies enabled the determination of nominal operating conditions for optical-CT scanning. "Finger" phantoms are introduced as a powerful and flexible tool for the investigation of optical-CT performance. The modulation-transfer function (MTF) of the system is determined to be better than 10% out to 1 mm(-1), confirming sub-mm imaging ability. System performance is demonstrated by the acquisition of a 1 x 1 x 1 mm3 dataset through the dose distribution delivered by an x-ray lens that focuses x rays in the energy range 40-80 KeV. This 3D measurement would be extremely difficult to achieve with other dosimetry techniques and highlights some of the strengths of gel dosimetry. Finally, an optical Monte Carlo model is introduced and shown to have potential to model light transport through gel-dosimetry systems, and to provide a tool for the study and optimization of optical-CT gel dosimetry. The model utilizes Mie scattering theory and requires knowledge of the variation of the particle size distribution with dose. The latter was determined here using the technique of dynamic-light-scattering.
Collapse
Affiliation(s)
- Mark Oldham
- William Beaumont Hospital, Royal Oak, Michigan 48073-6769, USA.
| | | | | | | | | |
Collapse
|
36
|
Mather ML, De Deene Y, Whittaker AK, Simon GP, Rutgers R, Baldock C. Investigation of ultrasonic properties of PAG and MAGIC polymer gel dosimeters. Phys Med Biol 2002; 47:4397-409. [PMID: 12539980 DOI: 10.1088/0031-9155/47/24/307] [Citation(s) in RCA: 74] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Ultrasonic speed of propagation and attenuation were investigated as a function of absorbed radiation dose in PAG and MAGIC polymer gel dosimeters. Both PAG and MAGIC gel dosimeters displayed a dependence of ultrasonic parameters on absorbed dose with attenuation displaying significant changes in the dose range investigated. The ultrasonic attenuation dose sensitivity at 4 MHz in MAGIC gels was determined to be 4.7 +/- 0.3 dB m(-1) Gy(-1) and for PAG 3.9 +/- 0.3 dB m(-1) Gy(-1). Ultrasonic speed dose sensitivities were 0.178 +/- 0.006 m s(-1) Gy(-1) for MAGIC gel and -0.44 +/- 0.02 m s(-1) Gy(-1) for PAG. Density and compressional elastic modulus were investigated to explain the different sensitivities of ultrasonic speed to radiation for PAG and MAGIC gels. The different sensitivities were found to be due to differences in the compressional elastic modulus as a function of dose for the two formulations. To understand the physical phenomena underlying the increase in ultrasonic attenuation with dose, the viscoelastic properties of the gels were studied. Results suggest that at ultrasonic frequencies, attenuation in polymer gel dosimeters is primarily due to volume viscosity. It is concluded that ultrasonic attenuation significantly increases with absorbed dose. Also, the ultrasonic speed in polymer gel dosimeters is affected by changes in dosimeter elastic modulus that are likely to be a result of polymerization. It is suggested that ultrasound is a sufficiently sensitive technique for polymer gel dosimetry.
Collapse
Affiliation(s)
- Melissa L Mather
- Centre for Medical, Health and Environmental Physics, Queensland University of Technology, Brisbane, Australia
| | | | | | | | | | | |
Collapse
|
37
|
Borden JA, Tsai JS, Mahajan A. Effect of subpixel magnetic resonance imaging shifts on radiosurgical dosimetry for vestibular schwannoma. J Neurosurg 2002. [DOI: 10.3171/jns.2002.97.supplement_5.0445] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Object. The purpose of this study was to evaluate subpixel magnetic resonance (MR) imaging shifts of intracanalicular vestibular schwannomas (VSs) with respect to the internal auditory canal (IAC) as documented on computerized tomography (CT) scanning and to investigate the source of imaging-related localization errors in radiosurgery as well as the effect of such shifts on the dosimetry for small targets.
Methods. A shift of the stereotactic coordinates of intracanalicular VSs between those determined on MR imaging and those on CT scanning represents an error in localization. A shift vector places the tumor within the IAC and measures the CT scan/MR image discrepancy. The shift vectors were measured in a series of 15 largely intracanalicular VSs (all < 1.5 cm3 in volume). Using dose volume histogram measurements, the overlap between shifted and unshifted tumors and radiosurgical treatment plans were measured. Using plastic and bone phantoms and thermoluminescent dosimetry measurements, the correspondence between CT and MR imaging targets and treatments delivered using the Leksell gamma knife were measured. Combining these measurements, the correspondence between intended and actual treatments was measured.
Conclusions. The delivery of radiation to CT-imaged targets was accurate to the limits of measurement (∼ 0.1 mm). The MR imaging shifts seen in the y axis averaged 0.9 mm and in the z axis 0.8 mm. The corresponding percentage of tumor coverage with respect to apparent target shift decreased from 98 to 77%. This represents a significant potential error when targets are defined solely by MR imaging.
Collapse
|
38
|
MacDougall ND, Pitchford WG, Smith MA. A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry. Phys Med Biol 2002; 47:R107-21. [PMID: 12433119 DOI: 10.1088/0031-9155/47/20/201] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
The purpose of this work is to undertake a critical appraisal of the evidence in the published literature concerning the basic parameters of accuracy and precision associated with the use of Fricke and polymer gels (in conjunction with MR imaging) as radiation dosimeters in photon radiotherapy, condensing and analysing the body of published information (to the end of April 2002). A systematic review was undertaken addressing specific issues of precision and accuracy asking defined questions of the published literature. Accuracy and precision in relation to gel dosimetry were defined. Information was obtained from published, peer-reviewed journals. A defined search strategy utilizing MeSH headings and keywords, with extensive use of cross-referencing, identified 115 references dealing with gel dosimetry. Exclusion criteria were used to select only data from publications which would give unequivocal evidence. For accuracy, results had to be compared with an ionization chamber as gold standard and all gel samples had to be manufactured in the same batch. For precision, in addition to gels being from the same batch, samples must all have been irradiated at the same time and scanned simultaneously (or within a short time frame). Many results were found demonstrating 'dose mapping' examples using gels. However, there were very few publications containing firm evidence of precision and accuracy. There was no evidence which fulfilled our criteria about accuracy or precision using Fricke gels. For polymer gels only one paper was found for accuracy (4% (Low et al 1999 Med. Phys. 26 1542-51)) and precision (1.7% (Baldock et al 1998 Phys. Med. Biol. 43695-702)); however, both were carried out at only one dose level. If the exclusion criteria were relaxed to include accuracy results comparing gel to a non gold standard dosimeter (e.g. TLD), results give a median accuracy of 10% (range 8-23.5%) for polymer gel (Cosgrove et al 2000 Phys. Med. Biol. 45 1195-210, De Deene et al 1998 Radiother: Oncol. 48 283-91, Farajollahi et al 2000 Br. J. Radiol. 72 1085-92, McJury et al 1999b Phys. Med. Biol. 44 2431-44, Murphy et al 2000b Phys. Med. Biol. 45 835-45, Oldham et al 2001 Med. Phys. 28 1436-45) and 5% for Fricke gel (Chan and Ayyangar 1995b Med. Phys. 22 1171-5). Evidence also points to accuracy worsening at lower dose levels for both gels. The precision data should be viewed with caution as repeated MR measurements were not performed with the same samples. The only precision data for Fricke gels was 1.5% (Johansson Back et al 1998 Phys. Med. Biol. 43 261-76), but for zero dose. In conclusion, despite the amount of published data, sparse research has been undertaken which provides clear evidence of the accuracy and precision for both gels. That which has been published has used higher doses than would be routine in radiotherapy. The basic radiation dosimeter qualities of accuracy and precision have yet to be fully quantified for polymer and Fricke gels at clinically relevant dose levels.
Collapse
Affiliation(s)
- N D MacDougall
- Department of Medical Physics, Cookridge Hospital, Leeds, UK
| | | | | |
Collapse
|
39
|
Abstract
To meet the requirements for 3D dose verification of high-precision radiotherapy treatments (such as in intensity modulated radiotherapy; IMRT), two different kinds of gel dosimeters were developed. In the Fricke gel, an oxidation of ferrous-ions into ferric-ions occurs upon irradiation. As the ferrous and ferric ions possess different magnetic moments, the dose distribution can be read out by use of magnetic resonance imaging (MRI). However, this method is susceptible to spatial instabilities as the ions are able to diffuse through the gel matrix. Attempts have been made to reduce the diffusion by changing the gelling substance. In monomer/polymer gel dosimetry, the spin-spin relaxation rate, R2, is related to the radiation dose that was delivered to the phantom, as ionizing irradiation causes the formation of polymer aggregates. The intended target figure of accuracy in gel dosimetry for IMRT is approximately 3% to 5% of the maximum dose. However, in a conventional MR scanner several imaging artefacts may cause dose inaccuracies. Studies of these different artefacts have resulted in different compensation strategies, otherwise the dose maps will also contain stochastic noise. To minimize the stochastic noise in the images, the imaging sequence parameters should be optimized. Monomer/polymer gels are proven to be valuable dosimeters for IMRT applications. They are able to provide a three-dimensional dose distribution that is integrated over all beams delivered in the treatment. The gels can be molded in humanoid shapes. As a result, gel dosimeters are able to simulate the complete treatment. Gel dosimetry can therefore be regarded as a dosimetric tool to verify dose distributions calculated by the computer planning. Furthermore, gel dosimetry has also been very useful in quality control and investigation of extreme beam configurations possibly occurring in IMRT, in dose verification after implementation of additional devices, and in investigating dose disturbances by low-density structures. The search for new chemical compositions may result in dosimeter gels that are easier to fabricate and possess higher sensitivity. Besides MRI, other imaging techniques are investigated to read out the dosimeters.
Collapse
Affiliation(s)
- Yves De Deene
- Division of Radiotherapy, Ghent University Hospital, Belgium
| |
Collapse
|
40
|
Lepage M, McMahon K, Galloway GJ, De Deene Y, Bäck SAJ, Baldock C. Magnetization transfer imaging for polymer gel dosimetry. Phys Med Biol 2002; 47:1881-90. [PMID: 12108773 DOI: 10.1088/0031-9155/47/11/304] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Off-resonance RF pre-saturation was used to obtain contrast in MRI images of polymer gel dosimeters irradiated to doses up to 50 Gy. Two different polymer gel dosimeters composed of 2-hydroxyethyl-acrylate or methacrylic acid monomers mixed with N, N'-methylene-bisacrylamide (BIS), dispersed in an aqueous gelatin matrix were evaluated. Radiation-induced polymerization of the co-monomers generates a fast-relaxing insoluble polymer. Saturation of the polymer using off-resonance Gaussian RF pulses prior to a spin-echo readout with a short echo time leads to contrast that is dependent on the absorbed dose. This contrast is attributed to magnetization transfer (MT) between free water and the polymer, and direct saturation of water was found to be negligible under the prevailing experimental conditions. The usefulness of MT imaging was assessed by computing the dose resolution obtained with this technique. We found a low value of dose resolution over a wide range of doses could be obtained with a single experiment. This is an advantage over multiple spin echo (MSE) experiments using a single echo spacing where an optimal dose resolution is achieved over only very limited ranges of doses. The results suggest MT imaging protocols may be developed into a useful tool for polymer gel dosimetry.
Collapse
Affiliation(s)
- M Lepage
- Centre for Medical, Health and Environmental Physics, Queensland University of Technology, Brisbane, Australia.
| | | | | | | | | | | |
Collapse
|
41
|
Abstract
A new method for the evaluation of radiotherapy 3D polymer gel dosimeters has been developed using ultrasound to assess the significant structural changes that occur following irradiation of the dosimeters. The ultrasonic parameters of acoustic speed of propagation, attenuation and transmitted signal intensity were measured as a function of absorbed radiation dose. The dose sensitivities for each parameter were determined as 1.8 x 10(-4) s m(-1) Gy(-1), 3.9 dB m(-1) Gy(-1) and 3.2 V(-1) Gy(-1) respectively. All parameters displayed a strong variation with absorbed dose that continued beyond absorbed doses of 15 Gy. The ultrasonic measurements demonstrated a significantly larger dynamic range in dose response curves than that achieved with previously published magnetic resonance imaging (MRI) dose response data. It is concluded that ultrasound shows great potential as a technique for the evaluation of polymer gel dosimeters.
Collapse
Affiliation(s)
- Melissa L Mather
- Centre for Medical, Health and Environmental Physics, Queensland University of Technology, Brisbane, Australia
| | | | | |
Collapse
|
42
|
Jirasek A, Duzenli C. Relative effectiveness of polyacrylamide gel dosimeters applied to proton beams: Fourier transform Raman observations and track structure calculations. Med Phys 2002; 29:569-77. [PMID: 11991129 DOI: 10.1118/1.1460873] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
The feasibility of using polyacrylamide gel (PAG) to characterize a clinically relevant 74 MeV proton beam has been considered. Fourier transform Raman spectroscopy has been used to measure the response (i.e., consumption of monomer) of PAG exposed to the central and end portions of a spread out Bragg peak (SOBP), i.e., in two regions with measurable difference in proton linear energy transfer (LET). The response curve in each region was compared with a typical 6 MV x-ray irradiated gel response curve, thus arriving at a gel "relative effectiveness" (RE) in each of the two regions. In addition, the theory of track structure, which is typically used to calculate a detector RE, is shown to give reasonable agreement when compared with the experimental results. Both experimental and track structure results indicate a decrease in gel response when irradiated with protons, as compared with the x-ray response. In addition, both sets of results indicate a variation in gel response between the mid and end SOBP regions, thus illuminating the dependence of gel response to proton LET. The physical phenomenon causing a lower proton versus x-ray gel response may be understood by considering the track structure calculations, which indicate that gel radiosensitive elements close to the track of a proton (i.e., within 1.5 x 10(-6) cm) are saturated. This saturation is due to the high delta-ray doses deposited in these regions. The track calculations are extended to other situations (e.g., raw BP, different gel compositions) where experimental determination of RE is difficult or time consuming. Results again indicate a gel response dependent on position in the depth dose curve (i.e., LET). Overall, this study illuminates the difficulty in using polyacrylamide gel to extract quantitative dose maps when exposed to proton radiation.
Collapse
Affiliation(s)
- A Jirasek
- Department of Physics and Astronomy, University of British Columbia, Canada.
| | | |
Collapse
|
43
|
Audet C, Hilts M, Jirasek A, Duzenli C. CT gel dosimetry technique: comparison of a planned and measured 3D stereotactic dose volume. J Appl Clin Med Phys 2002; 3:110-8. [PMID: 11958651 PMCID: PMC5724611 DOI: 10.1120/jacmp.v3i2.2575] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2001] [Accepted: 01/25/2002] [Indexed: 11/23/2022] Open
Abstract
This study presents a 3D dose mapping of complex dose distributions using an x-ray computed tomography (CT) polymer gel dosimetry technique. Two polyacrylamide gels (PAGs) of identical composition were irradiated with the same four arc stereotactic treatment to maximum doses of 15 Gy (PAG1) and 8 Gy (PAG2). The PAGs were CT imaged using a previously defined protocol that involves image averaging and background subtraction to improve image quality. For comparison with the planned isodose distribution, the PAG images were converted to relative dose maps using a CT number-dose calibration curve or simple division. The PAG images were then co-registered with the planning CT images in the BrainLab treatment planning software which automatically provides reconstructed sagittal and coronal images for 3D evaluation of measured and planned dose. The hypo-intense high dose region in both sets of gel images agreed with the planned 80% isodose contour and was shifted by up to 1.5 and 3.0 mm in the axial and reconstructed planes, respectively. This demonstrates the ability of the CT gel technique to accurately localize the high dose region produced by the stereotactic treatment. The resulting agreement of the measured relative dose volume for PAG1 was within 3.0 mm for the 50% and 80% isodose surfaces. However, the dose contrast was too low in PAG2 to allow for accurate definition of measured relative dose surfaces. Thus, a PAG should be irradiated to higher doses if quantitative relative dose information is required. Unfortunately, this implies use of an additional PAG and its CT number dose response since doses greater than 8-10 Gy fall outside the linear regions of the response.
Collapse
MESH Headings
- Acrylamides/therapeutic use
- Gels/therapeutic use
- Humans
- Image Processing, Computer-Assisted/instrumentation
- Image Processing, Computer-Assisted/methods
- Imaging, Three-Dimensional/instrumentation
- Imaging, Three-Dimensional/methods
- Polymers/therapeutic use
- Radiation Dosage
- Radiosurgery/instrumentation
- Radiosurgery/methods
- Radiotherapy Dosage
- Radiotherapy Planning, Computer-Assisted/instrumentation
- Radiotherapy Planning, Computer-Assisted/methods
- Radiotherapy, Conformal/instrumentation
- Radiotherapy, Conformal/methods
- Tomography, X-Ray Computed/instrumentation
- Tomography, X-Ray Computed/methods
Collapse
Affiliation(s)
- C. Audet
- British Columbia Cancer AgencyBritish ColumbiaCanadaV5Z 4E6
- Palo Alto Medical FoundationPalo AltoCalifornia94305
| | - M. Hilts
- British Columbia Cancer AgencyBritish ColumbiaCanadaV5Z 4E6
| | - A. Jirasek
- British Columbia Cancer AgencyBritish ColumbiaCanadaV5Z 4E6
- Department of Physics and AstronomyUniversity of British ColumbiaVancouverCanadaV5Z 4E6
| | - C. Duzenli
- British Columbia Cancer AgencyBritish ColumbiaCanadaV5Z 4E6
| |
Collapse
|
44
|
Kipouros P, Pappas E, Baras P, Hatzipanayoti D, Karaiskos P, Sakelliou L, Sandilos P, Seimenis I. Wide dynamic dose range of VIPAR polymer gel dosimetry. Phys Med Biol 2001; 46:2143-59. [PMID: 11512616 DOI: 10.1088/0031-9155/46/8/308] [Citation(s) in RCA: 42] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In this work the extent of the linear dose response and the dynamic dose range of N-vinylpyrrolidone-argon based (VIPAR) polymer gels were investigated. VIPAR gels were irradiated using a 6 MV linear accelerator up to 60 Gy and a Nucletron microSelectron 192Ir HDR brachytherapy source to much higher doses to cover a dose range of two orders of magnitude. They were then MR scanned at 1.5 T to obtain T2-maps. VIPAR gel measurements obtained from the two irradiation regimes were calibrated against ion chamber measurements and dose calculations derived using the AAPM TG-43 protocol respectively. A satisfying agreement between the calibration results derived using the 6 MV x-rays and the 192Ir source was found for doses up to 60 Gy, implying that the response of the VIPAR gels is independent of photon energy and dose rate. A linear R2 dose response up to approximately 40 Gy and a dynamic dose range up to at least approximately 250 Gy were observed. VIPAR gel dose measurements derived using the monoexponentially fitted brachytherapy calibration data were found to be quite accurate.
Collapse
Affiliation(s)
- P Kipouros
- Physics Department, University of Athens, Panepistimioupolis, Ilisia, Greece
| | | | | | | | | | | | | | | |
Collapse
|
45
|
Baldoc C, Lepage M, Bäck SA, Murry PJ, Jayasekera PM, Porter D, Kron T. Dose resolution in radiotherapy polymer gel dosimetry: effect of echo spacing in MRI pulse sequence. Phys Med Biol 2001; 46:449-60. [PMID: 11229725 DOI: 10.1088/0031-9155/46/2/312] [Citation(s) in RCA: 124] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In polymer gel dosimetry using magnetic resonance imaging, the uncertainty in absorbed dose is dependent on the experimental determination of T2. The concept of dose resolution (Dpdelta) of polymer gel dosimeters is developed and applied to the uncertainty in dose related to the uncertainty in T2 from a range of T4 encountered in polymer gel dosimetry. Dpdelta is defined as the minimal separation between two absorbed doses such that they may be distinguished with a given level of confidence, p. The minimum detectable dose (MDD) is Dpdelta as the dose approaches zero. Dpdelta and the minimum detectable dose both give a quantifiable indication of the likely practical limitations and usefulness of the dosimeter. Dpdelta of a polyacrylamide polymer gel dosimeter is presented for customized 32-echo and standard multiple-spin-echo sequences on a clinical MRI scanner. In evaluating uncertainties in T2, a parameter of particular significance in the pulse sequence is the echo spacing (ES). For optimal results, ES should be selected to minimize Dpdelta over a range of doses of interest in polymer gel dosimetry.
Collapse
Affiliation(s)
- C Baldoc
- Centre for Medical and Health Physics, School of Physical Sciences, Queensland University of Technology, Brisbane, Australia.
| | | | | | | | | | | | | |
Collapse
|