1
|
Jankarashvili N, Kakhadze S, Topeshashvili M, Turkiasvili L, Tchiabrishvili M. Neoadjuvant volumetric modulated arc radiochemotherapy with a simultaneous integrated boost technique compared to standard chemoradiation for locally advanced rectal cancer. Turk J Med Sci 2019; 49:1484-1489. [PMID: 31651118 PMCID: PMC7018366 DOI: 10.3906/sag-1812-185] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2018] [Accepted: 08/07/2019] [Indexed: 12/23/2022] Open
Abstract
Background/aim The present study aimed to examine whether the combination of neoadjuvant volumetric modulated arc radiotherapy (VMAT) using simultaneous integrated boost (SIB-VMAT) techniques and chemotherapy with capecitabine is associated with better clinical and dosimetric outcomes compared to the standard treatment. Materials and methods The study included 59 patients with cT2–T4 rectal cancer. In the standard arm, patients (n = 37) were treated preoperatively with image-guided VMAT plus capecitabine. In the SIB arm, patients (n = 22) were treated with the SIB-VMAT technique plus capecitabine. All patients underwent radical surgical resection after neoadjuvant radiochemotherapy. Results In the standard arm, cT0N0 was reached in 12 patients (32.4%), primary tumor clinical downstaging was observed in 22 patients (59.5%), and disease stability was achieved in 3 patients (8.1%). In the SIB arm, cT0N0 was reached in 15 patients (68.2%), primary tumor clinical downstaging was observed in 6 patients (27.3%), and disease stability was achieved in 1 patient (4.5%) (P = 0.028). Complete pathological response was observed in 11 patients (29.7%) in the standard arm and in 13 patients (59.1%) in the SIB arm (P = 0.026). In the SIB arm mild diarrhea appeared in 59.1%, moderate in 40.9%, and severe in 0% of the cases. In the standard arm mild, moderate, and severe diarrhea rates were in 54.1%, 43.2%, and 2.7%, respectively. In the SIB arm mild, moderate, and severe cystitis appeared in 63.6%, 22.7%, and 13.6%, while in the standard group mild cystitis developed in 67.6%, moderate in 24.3%, and severe in 8.1%. Mild, moderate, and severe radiation dermatitis rates were 45.5%, 45.5%, and 9.1% in the SIB group and 40.5%, 48.6%, and 10.8% in the standard group, respectively. Conclusion The SIB-VMAT technique is effective and safe for irradiating locally advanced rectal cancer. Its effectiveness is expressed in higher clinical and pathological complete response rates and safety with the same rates of acute toxicity.
Collapse
Affiliation(s)
- Natalia Jankarashvili
- Department of Radiation Oncology, Academician F. Todua Medical Center-Research Institute of Clinical Medicine, Tbilisi, Georgia
| | - Sophio Kakhadze
- Department of Radiology, Academician F. Todua Medical Center-Research Institute of Clinical Medicine, Tbilisi, Georgia
| | - Maia Topeshashvili
- Department of Radiation Oncology, Academician F. Todua Medical Center-Research Institute of Clinical Medicine, Tbilisi, Georgia
| | - Lasha Turkiasvili
- Department of Radiation Oncology, Academician F. Todua Medical Center-Research Institute of Clinical Medicine, Tbilisi, Georgia
| | - Mariam Tchiabrishvili
- Department of Radiation Oncology, Academician F. Todua Medical Center-Research Institute of Clinical Medicine, Tbilisi, Georgia
| |
Collapse
|
2
|
Cilla S, Deodato F, Ianiro A, Macchia G, Picardi V, Buwenge M, Cammelli S, Zamagni A, Valentini V, Morganti AG. Partially ablative radiotherapy (PAR) for large mass tumors using simultaneous integrated boost: A dose-escalation feasibility study. J Appl Clin Med Phys 2018; 19:35-43. [PMID: 30220111 PMCID: PMC6236838 DOI: 10.1002/acm2.12427] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Accepted: 07/12/2018] [Indexed: 12/22/2022] Open
Abstract
Purpose This study aimed to assess the feasibility to plan and deliver highly heterogeneous doses to symptomatic large tumors using volumetric modulated arc therapy (VMAT) and simultaneous integrated boost (SIB) during a short course palliative accelerated radiotherapy. Methods A patient with a large symptomatic chordoma infiltrating the right gluteal region was selected. A modified SIB treatment was implemented to irradiate the central volume of the tumor (boost target volume, BTV) up to 10 Gy/fraction in a dose escalation trial while maintaining the remaining tumor volume (planning target volume, PTV) and the surrounding healthy tissues within 5 Gy/fraction in twice daily fractions for two consecutive days. Four SIB plans were generated in the dual‐arc modality; a basal dose of 20 Gy was prescribed to the PTV, while the BTV was boosted up to 40 Gy. For comparison purposes, plans obtained with a sequential boost (SEQ plans) were also generated. All plans were optimized to deliver at least 95% of the prescription dose to the targets. Dose contrast index (DCI), conformity index (CI), integral dose (ID), and the irradiated body volumes at 5, 10, and 20 Gy were evaluated. Results At equal targets coverage, SIB plans provided major improvement in DCI, CI, and ID with respect to SEQ plans. When BTV dose escalated up to 200% of PTV prescription, DCI resulted in 66% for SIB plans and 37% for SEQ plans; the ID increase was only 11% for SIB plans (vs 27% for SEQ plans) and the increase in healthy tissues receiving more than 5, 10, and 20 Gy was less than 2%. Pretreatment dose verification reported a γ‐value passing rate greater than 95% with 3%(global)‐2 mm. Conclusion A modified SIB technique is dosimetrically feasible for large tumors, where doses higher than the tolerance dose of healthy tissues are necessary to increase the therapeutic gain.
Collapse
Affiliation(s)
- Savino Cilla
- Medical Physics Unit, Fondazione di Ricerca e Cura Giovanni Paolo II - Università Cattolica del Sacro Cuore, Campobasso, Italy
| | - Francesco Deodato
- Radiation Oncology Unit, Fondazione di Ricerca e Cura Giovanni Paolo II - Università Cattolica del Sacro Cuore, Campobasso, Italy
| | - Anna Ianiro
- Medical Physics Unit, Fondazione di Ricerca e Cura Giovanni Paolo II - Università Cattolica del Sacro Cuore, Campobasso, Italy
| | - Gabriella Macchia
- Radiation Oncology Unit, Fondazione di Ricerca e Cura Giovanni Paolo II - Università Cattolica del Sacro Cuore, Campobasso, Italy
| | - Vincenzo Picardi
- Radiation Oncology Unit, Fondazione di Ricerca e Cura Giovanni Paolo II - Università Cattolica del Sacro Cuore, Campobasso, Italy
| | - Milly Buwenge
- Radiation Oncology Department, DIMES Università di Bologna - Ospedale S.Orsola Malpighi, Bologna, Italy
| | - Silvia Cammelli
- Radiation Oncology Department, DIMES Università di Bologna - Ospedale S.Orsola Malpighi, Bologna, Italy
| | - Alice Zamagni
- Radiation Oncology Department, DIMES Università di Bologna - Ospedale S.Orsola Malpighi, Bologna, Italy
| | - Vincenzo Valentini
- Radiation Oncology Unit, Fondazione di Ricerca e Cura Giovanni Paolo II - Università Cattolica del Sacro Cuore, Campobasso, Italy.,Radiation Oncology Department, Policlinico Universitario A. Gemelli - Università Cattolica del Sacro Cuore, Roma, Italy
| | - Alessio G Morganti
- Radiation Oncology Department, DIMES Università di Bologna - Ospedale S.Orsola Malpighi, Bologna, Italy
| |
Collapse
|
3
|
Gurjar OP, Prasad Mishra S. A comparative study on patient specific absolute dosimetry using slab phantom, acrylic body phantom and goat head phantom. INTERNATIONAL JOURNAL OF CANCER THERAPY AND ONCOLOGY 2015. [DOI: 10.14319/ijcto.32.12] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
|
4
|
Barrett HH, Kupinski MA, Müeller S, Halpern HJ, Morris JC, Dwyer R. Objective assessment of image quality VI: imaging in radiation therapy. Phys Med Biol 2014; 58:8197-213. [PMID: 24200954 DOI: 10.1088/0031-9155/58/22/8197] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Earlier work on objective assessment of image quality (OAIQ) focused largely on estimation or classification tasks in which the desired outcome of imaging is accurate diagnosis. This paper develops a general framework for assessing imaging quality on the basis of therapeutic outcomes rather than diagnostic performance. By analogy to receiver operating characteristic (ROC) curves and their variants as used in diagnostic OAIQ, the method proposed here utilizes the therapy operating characteristic or TOC curves, which are plots of the probability of tumor control versus the probability of normal-tissue complications as the overall dose level of a radiotherapy treatment is varied. The proposed figure of merit is the area under the TOC curve, denoted AUTOC. This paper reviews an earlier exposition of the theory of TOC and AUTOC, which was specific to the assessment of image-segmentation algorithms, and extends it to other applications of imaging in external-beam radiation treatment as well as in treatment with internal radioactive sources. For each application, a methodology for computing the TOC is presented. A key difference between ROC and TOC is that the latter can be defined for a single patient rather than a population of patients.
Collapse
|
5
|
Lee TF, Chao PJ, Ting HM, Lo SH, Wang YW, Tuan CC, Fang FM, Su TJ. Comparative analysis of SmartArc-based dual arc volumetric-modulated arc radiotherapy (VMAT) versus intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma. J Appl Clin Med Phys 2011; 12:3587. [PMID: 22089015 PMCID: PMC5718754 DOI: 10.1120/jacmp.v12i4.3587] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2011] [Revised: 05/17/2011] [Accepted: 05/24/2011] [Indexed: 12/15/2022] Open
Abstract
The purpose of this study was to evaluate and quantify the planning performance of SmartArc‐based volumetric‐modulated arc radiotherapy (VMAT) versus fixed‐beam intensity‐modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC) using a sequential mode treatment plan. The plan quality and performance of dual arc‐VMAT (DA‐VMAT) using the Pinnacle3 Smart‐Arc system (clinical version 9.0; Philips, Fitchburg, WI, USA) were evaluated and compared with those of seven‐field (7F)‐IMRT in 18 consecutive NPC patients. Analysis parameters included the conformity index (CI) and homogeneity index (HI) for the planning target volume (PTV), maximum and mean dose, normal tissue complication probability (NTCP) for the specified organs at risk (OARs), and comprehensive quality index (CQI) for an overall evaluation in the 11 OARs. Treatment delivery time, monitor units per fraction (MU/fr), and gamma (Γ3mm,3%) evaluations were also analyzed. DA‐VMAT achieved similar target coverage and slightly better homogeneity than conventional 7F‐IMRT with a similar CI and HI. NTCP values were only significantly lower in the left parotid gland (for xerostomia) for DA‐VMAT plans. The mean value of CQI at 0.98±0.02 indicated a 2% benefit in sparing OARs by DA‐VMAT. The MU/fr used and average delivery times appeared to show improved efficiencies in DA‐VMAT. Each technique demonstrated high accuracy in dose delivery in terms of a high‐quality assurance (QA) passing rate (>98%) of the (Γ3mm,3%) criterion. The major difference between DA‐VMAT and 7F‐IMRT using a sequential mode for treating NPC cases appears to be improved efficiency, resulting in a faster delivery time and the use of fewer MU/fr. PACS number: 87.53.Tf, 87.55.x, 87.55.D, 87.55.dk
Collapse
Affiliation(s)
- Tsair-Fwu Lee
- Medical Physics & Informatics Lab., Department of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung, Taiwan.
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Petersson K, Ceberg C, Engström P, Benedek H, Nilsson P, Knöös T. Conversion of helical tomotherapy plans to step-and-shoot IMRT plans--Pareto front evaluation of plans from a new treatment planning system. Med Phys 2011; 38:3130-8. [PMID: 21815387 DOI: 10.1118/1.3592934] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The resulting plans from a new type of treatment planning system called SharePlan have been studied. This software allows for the conversion of treatment plans generated in a TomoTherapy system for helical delivery, into plans deliverable on C-arm linear accelerators (linacs), which is of particular interest for clinics with a single TomoTherapy unit. The purpose of this work was to evaluate and compare the plans generated in the SharePlan system with the original TomoTherapy plans and with plans produced in our clinical treatment planning system for intensity-modulated radiation therapy (IMRT) on C-arm linacs. In addition, we have analyzed how the agreement between SharePlan and TomoTherapy plans depends on the number of beams and the total number of segments used in the optimization. METHODS Optimized plans were generated for three prostate and three head-and-neck (H&N) cases in the TomoTherapy system, and in our clinical treatment planning systems (TPS) used for IMRT planning with step-and-shoot delivery. The TomoTherapy plans were converted into step-and-shoot IMRT plans in SharePlan. For each case, a large number of Pareto optimal plans were created to compare plans generated in SharePlan with plans generated in the Tomotherapy system and in the clinical TPS. In addition, plans were generated in SharePlan for the three head-and-neck cases to evaluate how the plan quality varied with the number of beams used. Plans were also generated with different number of beams and segments for other patient cases. This allowed for an evaluation of how to minimize the number of required segments in the converted IMRT plans without compromising the agreement between them and the original TomoTherapy plans. RESULTS The plans made in SharePlan were as good as or better than plans from our clinical system, but they were not as good as the original TomoTherapy plans. This was true for both the head-and-neck and the prostate cases, although the differences between the plans for the latter were small. The evaluation of the head-and-neck cases also showed that the plans generated in SharePlan were improved when more beams were used. The SharePlan Pareto front came close to the front for the TomoTherapy system when a sufficient number of beams were added. The results for plans generated with varied number of beams and segments demonstrated that the number of segments could be minimized with maintained agreement between SharePlan and TomoTherapy plans when 10-19 beams were used. CONCLUSIONS This study showed (using Pareto front evaluation) that the plans generated in Share-Plan are comparable to plans generated in other TPSs. The evaluation also showed that the plans generated in SharePlan could be improved with the use of more beams. To minimize the number of segments needed in a plan with maintained agreement between the converted IMRT plans and the original TomoTherapy plans, 10-19 beams should be used, depending on target complexity. SharePlan has proved to be useful and should thereby be a time-saving complement as a backup system for clinics with a single TomoTherapy system installed alongside conventional C-arm linacs.
Collapse
Affiliation(s)
- Kristoffer Petersson
- Medical Radiation Physics, Clinical Sciences, Lund University, Lund SE-221 85, Sweden.
| | | | | | | | | | | |
Collapse
|
7
|
Volumetric modulated arc therapy with simultaneous integrated boost for locally advanced rectal cancer. Clin Oncol (R Coll Radiol) 2011; 24:261-8. [PMID: 21820294 DOI: 10.1016/j.clon.2011.07.001] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2011] [Revised: 06/08/2011] [Accepted: 06/09/2011] [Indexed: 11/21/2022]
Abstract
AIMS To report the feasibility of volumetric modulated arc therapy (VMAT) for neoadjuvant radiotherapy in locally advanced rectal cancer in a dose-escalation protocol and simultaneous integrated boost (SIB) approach. Moreover, the VMAT technique was compared with three-dimensional conformal radiotherapy (3D-CRT) and fixed-field intensity modulated radiotherapy (IMRT), in terms of target coverage and irradiation of organs at risk. MATERIALS AND METHODS Eight patients with locally advanced rectal cancer were treated with the SIB-VMAT technique. The VMAT plans were compared with 3D-CRT and IMRT techniques in terms of several clinically dosimetric parameters. The number of monitor units and the delivery time were analysed to score the treatment efficiency. All plans were verified in a dedicated solid water phantom using a two-dimensional array of ionisation chambers. RESULTS All techniques meet the prescription goal for planning target volume coverage, with VMAT showing the highest level of conformality. VMAT is associated with 40, 53 and 58% reduction in the percentage of volume of small bowel irradiated to 30, 40 and 50Gy, compared with 3D-CRT. No significant differences were found with respect to SIB-IMRT. VMAT plans showed a significant reduction of monitor units by nearly 20% with respect to IMRT and reduced treatment time from 14 to 5min for a single fraction. CONCLUSIONS SIB-VMAT plans can be planned and carried out with high quality and efficiency for rectal cancer, providing similar sparing of organs at risk to SIB-IMRT and resulting in the most efficient treatment option. SIB-VMAT is currently our standard approach for radiotherapy of locally advanced rectal cancer.
Collapse
|
8
|
Yang W, Jones R, Read P, Benedict S, Sheng K. Standardized evaluation of simultaneous integrated boost plans on volumetric modulated arc therapy. Phys Med Biol 2010; 56:327-39. [DOI: 10.1088/0031-9155/56/2/003] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
9
|
Barrett HH, Wilson DW, Kupinski MA, Aguwa K, Ewell L, Hunter R, Müller S. Therapy Operating Characteristic (TOC) Curves and their Application to the Evaluation of Segmentation Algorithms. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2010; 7627:76270Z. [PMID: 20948981 DOI: 10.1117/12.844189] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
This paper presents a general framework for assessing imaging systems and image-analysis methods on the basis of therapeutic rather than diagnostic efficacy. By analogy to receiver operating characteristic (ROC) curves, it utilizes the Therapy Operating Characteristic or TOC curve, which is a plot of the probability of tumor control vs. the probability of normal-tissue complications as the overall level of a radiotherapy treatment beam is varied. The proposed figure of merit is the area under the TOC, denoted AUTOC. If the treatment planning algorithm is held constant, AUTOC is a metric for the imaging and image-analysis components, and in particular for segmentation algorithms that are used to delineate tumors and normal tissues. On the other hand, for a given set of segmented images, AUTOC can also be used as a metric for the treatment plan itself. A general mathematical theory of TOC and AUTOC is presented and then specialized to segmentation problems. Practical approaches to implementation of the theory in both simulation and clinical studies are presented. The method is illustrated with a a brief study of segmentation methods for prostate cancer.
Collapse
Affiliation(s)
- Harrison H Barrett
- College of Optical Sciences and Department of Radiology, University of Arizona, Tucson AZ
| | | | | | | | | | | | | |
Collapse
|
10
|
Dobler B, Koelbl O, Bogner L, Pohl F. Direct machine parameter optimization for intensity modulated radiation therapy (IMRT) of oropharyngeal cancer--a planning study. J Appl Clin Med Phys 2009; 10:4-15. [PMID: 19918235 PMCID: PMC5720568 DOI: 10.1120/jacmp.v10i4.3066] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2009] [Revised: 05/05/2009] [Accepted: 05/14/2009] [Indexed: 11/23/2022] Open
Abstract
The purpose of the study was to investigate the potential of direct machine parameter optimization (DMPO) to achieve parotid sparing without compromising target coverage in IMRT of oropharyngeal cancer as compared to fluence modulation with subsequent leaf sequencing (IM) and forward planned two‐step arc therapy (IMAT). IMRT plans were generated for 10 oropharyngeal cancer patients using DMPO and IM. The resulting dose volume histograms (DVH) were evaluated with regard to compliance with the dose volume objectives (DVO) and plan quality. DMPO met the DVO for the targets better than IM, but violated the DVO to the parotids in some cases. DMPO provided better target coverage and dose homogeneity than IM and was comparable to IMAT. Dose to the parotids (23Gy) was significantly lower than for IMAT (48Gy), but somewhat higher than for IM (20Gy). Parotid sparing with IM was, however, only achieved at the cost of target coverage and homogeneity. DMPO allows achieving parotid sparing in the treatment of oropharyngeal cancer without compromising target coverage and dose homogeneity in the target as compared to two‐step IMAT. Better overall plan quality can be delivered with less monitor units than with IM. PACS number: 87.50.Gi
Collapse
Affiliation(s)
- Barbara Dobler
- Department of Radiotherapy, Regensburg University Medical Center, Regensburg, Germany
| | - Oliver Koelbl
- Department of Radiotherapy, Regensburg University Medical Center, Regensburg, Germany
| | - Ludwig Bogner
- Department of Radiotherapy, Regensburg University Medical Center, Regensburg, Germany
| | - Fabian Pohl
- Department of Radiotherapy, Regensburg University Medical Center, Regensburg, Germany
| |
Collapse
|
11
|
IMRT of prostate cancer: a comparison of fluence optimization with sequential segmentation and direct step-and-shoot optimization. Strahlenther Onkol 2009; 185:379-83. [PMID: 19506821 DOI: 10.1007/s00066-009-1950-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2008] [Accepted: 02/12/2009] [Indexed: 10/20/2022]
Abstract
BACKGROUND AND PURPOSE Intensity-modulated radiation therapy (IMRT) has shown its superiority to three-dimensional conformal radiotherapy in the treatment of prostate cancer. Different optimization algorithms are available: algorithms which first optimize the fluence followed by a sequencing (IM), and algorithms which involve the machine parameters directly in the optimization process (DSS). The aim of this treatment-planning study is to compare both of them regarding dose distribution and treatment time. PATIENTS AND METHODS Ten consecutive patients with localized prostate cancer were enrolled for the planning study. The planning target volume and the rectum volume, urinary bladder and femoral heads as organs at risk were delineated. Average doses, the target dose homogeneity H, D(5), D(95), monitor units per fraction, and the number of segments were evaluated. RESULTS While there is only a small difference in the mean doses at rectum and bladder, there is a significant advantage for the target dose homogeneity in the DSS-optimized plans compared to the IM-optimized ones. Differences in the monitor units (nearly 10% less for DSS) and the number of segments are also statistically significant and reduce the treatment time. CONCLUSION Particularly with regard to the tumor control probability, the better homogeneity of the DSS-optimized plans is more profitable. The shorter treatment time is an improvement regarding intrafractional organ motion. The DSS optimizer results in a higher target dose homogeneity and, simultaneously, in a lower number of monitor units. Therefore, it should be preferred for IMRT of prostate cancer.
Collapse
|
12
|
Quality Control of Portal Imaging with PTW EPID QC PHANTOM. Strahlenther Onkol 2009; 185:56-60. [PMID: 19224148 DOI: 10.1007/s00066-009-1905-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2008] [Accepted: 10/15/2008] [Indexed: 10/21/2022]
Abstract
PURPOSE Quality assurance (QA) and quality control (QC) of different electronic portal imaging devices (EPID) and portal images with the PTW EPID QC PHANTOM. MATERIAL AND METHODS Characteristic properties of images of different file formats were measured on Siemens OptiVue500aSi, Siemens BeamView Plus, Elekta iView, and Varian PortalVision and analyzed with the epidSoft 2.0 program in four radiation therapy centers. The portal images were taken with Kodak X-OMAT V and the Kodak Portal Localisation ReadyPack films and evaluated with the same program. RESULTS The optimal exposition both for EPIDs and portal films of different kind was determined. For double exposition, the 2+1 MU values can be recommended in the case of Siemens OptiVue500aSi Elekta iView and Kodak Portal Localisation ReadyPack films, while for Siemens BeamView Plus, Varian PortalVision and Kodak X-OMAT V film 7+7 MU is recommended. CONCLUSION The PTW EPID QC PHANTOM can be used not only for amorphous silicon EPIDs but also for images taken with a video-based system or by using an ionization chamber matrix or for portal film. For analysis of QC tests, a standardized format (used at the acceptance test) should be applied, as the results are dependent on the file format used.
Collapse
|
13
|
Achterberg N, Müller RG. Multibeam tomotherapy: a new treatment unit devised for multileaf collimation, intensity-modulated radiation therapy. Med Phys 2007; 34:3926-42. [PMID: 17985638 DOI: 10.1118/1.2779129] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
A fully integrated system for treatment planning, application, and verification for automated multileaf collimator (MLC) based, intensity-modulated, image-guided, and adaptive radiation therapy (IMRT, IGRT and ART, respectively) is proposed. Patient comfort, which was the major development goal, will be achieved through a new unit design and short treatment times. Our device for photon beam therapy will consist of a new dual energy linac with five fixed treatment heads positioned evenly along one plane but one electron beam generator only. A minimum of moving parts increases technical reliability and reduces motion times to a minimum. Motion is allowed solely for the MLCs, the robotic patient table, and the small angle gantry rotation of +/- 36 degrees. Besides sophisticated electron beam guidance, this compact setup can be built using existing modules. The flattening-filter-free treatment heads are characterized by reduced beam-on time and contain apertures restricted in one dimension to the area of maximum primary fluence output. In the case of longer targets, this leads to a topographic intensity modulation, thanks to the combination of "step and shoot" MLC delivery and discrete patient couch motion. Owing to the limited number of beam directions, this multislice cone beam serial tomotherapy is referred to as "multibeam tomotherapy." Every patient slice is irradiated by one treatment head at any given moment but for one subfield only. The electron beam is then guided to the next head ready for delivery, while the other heads are preparing their leaves for the next segment. The "Multifocal MLC-positioning" algorithm was programmed to enable treatment planning and optimize treatment time. We developed an overlap strategy for the longitudinally adjacent fields of every beam direction, in doing so minimizing the field match problem and the effects of possible table step errors. Clinical case studies show for the same or better planning target volume coverage, better organ-at-risk sparing, and comparable mean integral dose to the normal tissue a reduction in treatment time by more than 50% to only a few minutes in comparison to high-quality 3-D conformal and IMRT treatments. As a result, it will be possible to incorporate features for better patient positioning and image guidance, while sustaining reasonable overall treatment times at the same time. The virtual multibeam tomotherapy design study TOM'5-CT contains a dedicated electron beam CT (TOM'AGE) and an objective optical topometric patient positioning system (TOPOS). Thanks to the wide gantry bore of 120 cm and slim gantry depths of 70 cm, patients can be treated very comfortably, in all cases tumor-isocentrically, as well as with noncoplanar beam arrangements as in stereotactic radiosurgery with a couch rotation of up to +/- 54 degrees. The TOM'5 treatment unit on which this theoretical concept is based has a stand-alone depth of 40 cm and an outer diameter of 245 cm; the focus-isocenter distance of the heads is 100 cm with a field size of 40 cm x 7 cm and 0.5 cm leaves, which operate perpendicular to the axis of table motion.
Collapse
Affiliation(s)
- Nils Achterberg
- Strahlenklinik, Universitätsklinikum Erlangen, Universitätstrasse 27, 91054 Erlangen, Germany.
| | | |
Collapse
|
14
|
Raaijmakers AJE, Hårdemark B, Raaymakers BW, Raaijmakers CPJ, Lagendijk JJW. Dose optimization for the MRI-accelerator: IMRT in the presence of a magnetic field. Phys Med Biol 2007; 52:7045-54. [DOI: 10.1088/0031-9155/52/23/018] [Citation(s) in RCA: 69] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
15
|
Dobler B, Pohl F, Bogner L, Koelbl O. Comparison of direct machine parameter optimization versus fluence optimization with sequential sequencing in IMRT of hypopharyngeal carcinoma. Radiat Oncol 2007; 2:33. [PMID: 17822529 PMCID: PMC2075520 DOI: 10.1186/1748-717x-2-33] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2007] [Accepted: 09/06/2007] [Indexed: 11/27/2022] Open
Abstract
Background To evaluate the effects of direct machine parameter optimization in the treatment planning of intensity-modulated radiation therapy (IMRT) for hypopharyngeal cancer as compared to subsequent leaf sequencing in Oncentra Masterplan v1.5. Methods For 10 hypopharyngeal cancer patients IMRT plans were generated in Oncentra Masterplan v1.5 (Nucletron BV, Veenendal, the Netherlands) for a Siemens Primus linear accelerator. For optimization the dose volume objectives (DVO) for the planning target volume (PTV) were set to 53 Gy minimum dose and 59 Gy maximum dose, in order to reach a dose of 56 Gy to the average of the PTV. For the parotids a median dose of 22 Gy was allowed and for the spinal cord a maximum dose of 35 Gy. The maximum DVO to the external contour of the patient was set to 59 Gy. The treatment plans were optimized with the direct machine parameter optimization ("Direct Step & Shoot", DSS, Raysearch Laboratories, Sweden) newly implemented in Masterplan v1.5 and the fluence modulation technique ("Intensity Modulation", IM) which was available in previous versions of Masterplan already. The two techniques were compared with regard to compliance to the DVO, plan quality, and number of monitor units (MU) required per fraction dose. Results The plans optimized with the DSS technique met the DVO for the PTV significantly better than the plans optimized with IM (p = 0.007 for the min DVO and p < 0.0005 for the max DVO). No significant difference could be observed for compliance to the DVO for the organs at risk (OAR) (p > 0.05). Plan quality, target coverage and dose homogeneity inside the PTV were superior for the plans optimized with DSS for similar dose to the spinal cord and lower dose to the normal tissue. The mean dose to the parotids was lower for the plans optimized with IM. Treatment plan efficiency was higher for the DSS plans with (901 ± 160) MU compared to (1151 ± 157) MU for IM (p-value < 0.05). Renormalization of the IM plans to the mean of the dose to 95% of the PTV (D95) of the DSS plans, resulted in similar target coverage and dose to the parotids for both strategies, at the cost of a significantly higher dose to the normal tissue and maximum dose to the target. The relative volume of the PTV receiving 107% or more of the prescription dose V107 increased to 35.5% ± 20.0% for the IM plan as compared to a mean of 0.9% ± 0.9% for the DSS plan. Conclusion The direct machine parameter optimization is a major improvement compared to the fluence modulation with subsequent leaf sequencing in Oncentra Masterplan v1.5. The resulting dose distribution complies better with the DVO and better plan quality is achieved for identical specification of DVO. An additional asset is the reduced number of MU as compared to IM.
Collapse
Affiliation(s)
- Barbara Dobler
- Department of Radiotherapy, University of Regensburg, Regensburg, Germany
| | - Fabian Pohl
- Department of Radiotherapy, University of Regensburg, Regensburg, Germany
| | - Ludwig Bogner
- Department of Radiotherapy, University of Regensburg, Regensburg, Germany
| | - Oliver Koelbl
- Department of Radiotherapy, University of Regensburg, Regensburg, Germany
| |
Collapse
|
16
|
|