1
|
Yitbarek D, Dagnaw GG. Application of Advanced Imaging Modalities in Veterinary Medicine: A Review. Vet Med (Auckl) 2022; 13:117-130. [PMID: 35669942 PMCID: PMC9166686 DOI: 10.2147/vmrr.s367040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Accepted: 05/26/2022] [Indexed: 11/28/2022]
Abstract
Veterinary anatomy has traditionally relied on detailed dissections to produce anatomical illustrations, but modern imaging modalities, now represent an enormous resource that allows for fast non-invasive visualizations in living animals for clinical and research purposes. In this review, advanced anatomical imaging modalities and their applications, safety issues, challenges, and future prospects of the techniques commonly employed for animal imaging would be highlighted. The quality of diagnostic imaging equipment in veterinary practice has greatly improved. Recent advances made in veterinary advanced imaging specifically about cross-sectional modalities (CT and MRI), nuclear medicine (PET, SPECT), and dual imaging modalities (PET/CT, PET/MR, and SPECT/CT) have become widely available, leading to greater demands and expectations from veterinary clients. These modalities allow for the creation of three-dimensional representations that can be of considerable value in the dissemination of clinical diagnosis and anatomical studies. Despite, the modern imaging modalities well established in developed countries across the globe, it is yet to remain in its infancy stage in veterinary practice in developing countries due to heavy initial investment and maintenance costs, lack of expert interpretation, a requirement of specialized technical staff and need of adjustable machines to accommodate the different range of animal sizes. Therefore, veterinarians should take advantage of these imaging techniques in designing future experiments by considering the availability of these varied imaging modalities and the creation of three-dimensional graphical representations of internal structures.
Collapse
Affiliation(s)
| | - Gashaw Getaneh Dagnaw
- Department of Biomedical Sciences, College of Veterinary Medicine and Animal Sciences, University of Gondar, Gondar, Ethiopia
- Correspondence: Gashaw Getaneh Dagnaw, Department of Biomedical Sciences, College of Veterinary Medicine and Animal Sciences, University of Gondar, P.O. Box: 196, Gondar, Ethiopia, Email
| |
Collapse
|
2
|
Reconstruction of Preclinical PET Images via Chebyshev Polynomial Approximation of the Sinogram. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12073335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Over the last decades, there has been an increasing interest in dedicated preclinical imaging modalities for research in biomedicine. Especially in the case of positron emission tomography (PET), reconstructed images provide useful information of the morphology and function of an internal organ. PET data, stored as sinograms, involve the Radon transform of the image under investigation. The analytical approach to PET image reconstruction incorporates the derivative of the Hilbert transform of the sinogram. In this direction, in the present work we present a novel numerical algorithm for the inversion of the Radon transform based on Chebyshev polynomials of the first kind. By employing these polynomials, the computation of the derivative of the Hilbert transform of the sinogram is significantly simplified. Extending the mathematical setting of previous research based on Chebyshev polynomials, we are able to efficiently apply our new Chebyshev inversion scheme for the case of analytic preclinical PET image reconstruction. We evaluated our reconstruction algorithm on projection data from a small-animal image quality (IQ) simulated phantom study, in accordance with the NEMA NU 4-2008 standards protocol. In particular, we quantified our reconstructions via the image quality metrics of percentage standard deviation, recovery coefficient, and spill-over ratio. The projection data employed were acquired for three different Poisson noise levels: 100% (NL1), 50% (NL2), and 20% (NL3) of the total counts, respectively. In the uniform region of the IQ phantom, Chebyshev reconstructions were consistently improved over filtered backprojection (FBP), in terms of percentage standard deviation (up to 29% lower, depending on the noise level). For all rods, we measured the contrast-to-noise-ratio, indicating an improvement of up to 68% depending on the noise level. In order to compare our reconstruction method with FBP, at equal noise levels, plots of recovery coefficient and spill-over ratio as functions of the percentage standard deviation were generated, after smoothing the NL3 reconstructions with three different Gaussian filters. When post-smoothing was applied, Chebyshev demonstrated recovery coefficient values up to 14% and 42% higher, for rods 1–3 mm and 4–5 mm, respectively, compared to FBP, depending on the smoothing sigma values. Our results indicate that our Chebyshev-based analytic reconstruction method may provide PET reconstructions that are comparable to FBP, thus yielding a good alternative to standard analytic preclinical PET reconstruction methods.
Collapse
|
3
|
de Moura LD, Ribeiro LNM, de Carvalho FV, Rodrigues da Silva GH, Lima Fernandes PC, Brunetto SQ, Ramos CD, Velloso LA, de Araújo DR, de Paula E. Docetaxel and Lidocaine Co-Loaded (NLC-in-Hydrogel) Hybrid System Designed for the Treatment of Melanoma. Pharmaceutics 2021; 13:pharmaceutics13101552. [PMID: 34683846 PMCID: PMC8537790 DOI: 10.3390/pharmaceutics13101552] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Revised: 09/16/2021] [Accepted: 09/19/2021] [Indexed: 01/02/2023] Open
Abstract
Melanoma is the most aggressive skin carcinoma and nanotechnology can bring new options for its pharmacological treatment. Nanostructured lipid carriers (NLC) are ideal drug-delivery carriers for hydrophobic drugs, such as the antineoplastic docetaxel (DTX), and hybrid (NLC-in-hydrogel) systems are suitable for topical application. This work describes a formulation of NLCDTX in xanthan-chitosan hydrogel containing lidocaine (LDC) with anticancer and analgesia effects. The optimized nanoparticles encapsulated 96% DTX and rheological analysis revealed inherent viscoelastic properties of the hydrogel. In vitro assays over murine fibroblasts (NIH/3T3) and melanoma cells (B16-F10), human keratinocytes (HaCaT) and melanoma cells (SK-MEL-103) showed reduction of docetaxel cytotoxicity after encapsulation in NLCDTX and HGel-NLCDTX. Addition of LDC to the hybrid system (HGel-NLCDTX-LDC) increased cell death in tumor and normal cells. In vivo tests on C57BL/6J mice with B16-F10-induced melanoma indicated that LDC, NLCDTX, HGel-NLCDTX-LDC and NLCDTX + HGel-LDC significantly inhibited tumor growth while microPET/SPECT/CT data suggest better prognosis with the hybrid treatment. No adverse effects were observed in cell survival, weight/feed-consumption or serum biochemical markers (ALT, AST, creatinine, urea) of animals treated with NLCDTX or the hybrid system. These results confirm the adjuvant antitumor effect of lidocaine and endorse HGel-NLCDTX-LDC as a promising formulation for the topical treatment of melanoma.
Collapse
Affiliation(s)
- Ludmilla David de Moura
- Department of Biochemistry and Tissue Biology, Institute of Biology, University of Campinas—UNICAMP, Campinas 13083-862, SP, Brazil; (L.D.d.M.); (L.N.M.R.); (F.V.d.C.); (G.H.R.d.S.); (P.C.L.F.)
| | - Lígia N. M. Ribeiro
- Department of Biochemistry and Tissue Biology, Institute of Biology, University of Campinas—UNICAMP, Campinas 13083-862, SP, Brazil; (L.D.d.M.); (L.N.M.R.); (F.V.d.C.); (G.H.R.d.S.); (P.C.L.F.)
- Institute of Biotechnology, Federal University of Uberlândia—UFU, Uberlândia 38405-319, MG, Brazil
| | - Fabíola V. de Carvalho
- Department of Biochemistry and Tissue Biology, Institute of Biology, University of Campinas—UNICAMP, Campinas 13083-862, SP, Brazil; (L.D.d.M.); (L.N.M.R.); (F.V.d.C.); (G.H.R.d.S.); (P.C.L.F.)
| | - Gustavo H. Rodrigues da Silva
- Department of Biochemistry and Tissue Biology, Institute of Biology, University of Campinas—UNICAMP, Campinas 13083-862, SP, Brazil; (L.D.d.M.); (L.N.M.R.); (F.V.d.C.); (G.H.R.d.S.); (P.C.L.F.)
| | - Priscila C. Lima Fernandes
- Department of Biochemistry and Tissue Biology, Institute of Biology, University of Campinas—UNICAMP, Campinas 13083-862, SP, Brazil; (L.D.d.M.); (L.N.M.R.); (F.V.d.C.); (G.H.R.d.S.); (P.C.L.F.)
| | - Sérgio Q. Brunetto
- Radiology Department, University of Campinas—UNICAMP, Campinas 13083-887, SP, Brazil; (S.Q.B.); (C.D.R.)
| | - Celso D. Ramos
- Radiology Department, University of Campinas—UNICAMP, Campinas 13083-887, SP, Brazil; (S.Q.B.); (C.D.R.)
| | - Lício A. Velloso
- Clinical Medicine Department, School of Medicine Science, University of Campinas—UNICAMP, Campinas 13083-887, SP, Brazil;
| | - Daniele R. de Araújo
- Human and Natural Science Center, ABC Federal University—UFABC, Santo André 09210-580, SP, Brazil;
| | - Eneida de Paula
- Department of Biochemistry and Tissue Biology, Institute of Biology, University of Campinas—UNICAMP, Campinas 13083-862, SP, Brazil; (L.D.d.M.); (L.N.M.R.); (F.V.d.C.); (G.H.R.d.S.); (P.C.L.F.)
- Correspondence:
| |
Collapse
|
4
|
Groll AN, Levin CS. Instrumentation and Methods to Combine Small-Animal PET With Other Imaging Modalities. Mol Imaging 2021. [DOI: 10.1016/b978-0-12-816386-3.00005-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
5
|
Badea CT. Principles of Micro X-ray Computed Tomography. Mol Imaging 2021. [DOI: 10.1016/b978-0-12-816386-3.00006-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
6
|
Song D, Shujaat S, Zhao R, Huang Y, Shaheen E, Van Dessel J, Orhan K, Vande Velde G, Coropciuc R, Pauwels R, Politis C, Jacobs R. In vivo quantification of mandibular bone remodeling and vascular changes in a Wistar rat model: A novel HR-MRI and micro-CT fusion technique. Imaging Sci Dent 2020; 50:199-208. [PMID: 33005577 PMCID: PMC7506089 DOI: 10.5624/isd.2020.50.3.199] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 06/07/2020] [Accepted: 06/25/2020] [Indexed: 12/16/2022] Open
Abstract
Purpose This study was performed to introduce an in vivo hybrid multimodality technique involving the coregistration of micro-computed tomography (micro-CT) and high-resolution magnetic resonance imaging (HR-MRI) to concomitantly visualize and quantify mineralization and vascularization at follow-up in a rat model. Materials and Methods Three adult female rats were randomly assigned as test subjects, with 1 rat serving as a control subject. For 20 weeks, the test rats received a weekly intravenous injection of 30 µg/kg zoledronic acid, and the control rat was administered a similar dose of normal saline. Bilateral extraction of the lower first and second molars was performed after 10 weeks. All rats were scanned once every 4 weeks with both micro-CT and HR-MRI. Micro-CT and HR-MRI images were registered and fused in the same 3-dimensional region to quantify blood flow velocity and trabecular bone thickness at T0 (baseline), T4 (4 weeks), T8 (8 weeks), T12 (12 weeks), T16 (16 weeks), and T20 (20 weeks). Histological assessment was the gold standard with which the findings were compared. Results The histomorphometric images at T20 aligned with the HR-MRI findings, with both test and control rats demonstrating reduced trabecular bone vasculature and blood vessel density. The micro-CT findings were also consistent with the histomorphometric changes, which revealed that the test rats had thicker trabecular bone and smaller marrow spaces than the control rat. Conclusion The combination of micro-CT and HR-MRI may be considered a powerful non-invasive novel technique for the longitudinal quantification of localized mineralization and vascularization.
Collapse
Affiliation(s)
- Dandan Song
- OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Sohaib Shujaat
- OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Ruiting Zhao
- OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Yan Huang
- OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Eman Shaheen
- OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Jeroen Van Dessel
- OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Kaan Orhan
- OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.,Department of Dentomaxillofacial Radiology, Faculty of Dentistry, University of Ankara, Ankara, Turkey
| | - Greetje Vande Velde
- Biomedical MRI, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium
| | - Ruxandra Coropciuc
- OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Ruben Pauwels
- OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.,Department of Radiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.,Aarhus Institute of Advanced Studies, Aarhus University, Aarhus, Denmark
| | - Constantinus Politis
- OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Reinhilde Jacobs
- OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.,Department of Dental Medicine, Karolinska Institute, Stockholm, Sweden
| |
Collapse
|
7
|
Rogers CJ, Lukaszewicz AI, Yamada-Hanff J, Micewicz ED, Ratikan JA, Starbird MA, Miller TA, Nguyen C, Lee JT, Olafsen T, Iwamoto KS, McBride WH, Schaue D, Menon N. Identification of miRNA signatures associated with radiation-induced late lung injury in mice. PLoS One 2020; 15:e0232411. [PMID: 32392259 PMCID: PMC7213687 DOI: 10.1371/journal.pone.0232411] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Accepted: 04/14/2020] [Indexed: 01/03/2023] Open
Abstract
Acute radiation exposure of the thorax can lead to late serious, and even life-threatening, pulmonary and cardiac damage. Sporadic in nature, late complications tend to be difficult to predict, which prompted this investigation into identifying non-invasive, tissue-specific biomarkers for the early detection of late radiation injury. Levels of circulating microRNA (miRNA) were measured in C3H and C57Bl/6 mice after whole thorax irradiation at doses yielding approximately 70% mortality in 120 or 180 days, respectively (LD70/120 or 180). Within the first two weeks after exposure, weight gain slowed compared to sham treated mice along with a temporary drop in white blood cell counts. 52% of C3H (33 of 64) and 72% of C57Bl/6 (46 of 64) irradiated mice died due to late radiation injury. Lung and heart damage, as assessed by computed tomography (CT) and histology at 150 (C3H mice) and 180 (C57Bl/6 mice) days, correlated well with the appearance of a local, miRNA signature in the lung and heart tissue of irradiated animals, consistent with inherent differences in the C3H and C57Bl/6 strains in their propensity for developing radiation-induced pneumonitis or fibrosis, respectively. Radiation-induced changes in the circulating miRNA profile were most prominent within the first 30 days after exposure and included miRNA known to regulate inflammation and fibrosis. Importantly, early changes in plasma miRNA expression predicted survival with reasonable accuracy (88-92%). The miRNA signature that predicted survival in C3H mice, including miR-34a-5p, -100-5p, and -150-5p, were associated with pro-inflammatory NF-κB-mediated signaling pathways, whereas the signature identified in C57Bl/6 mice (miR-34b-3p, -96-5p, and -802-5p) was associated with TGF-β/SMAD signaling. This study supports the hypothesis that plasma miRNA profiles could be used to identify individuals at high risk of organ-specific late radiation damage, with applications for radiation oncology clinical practice or in the context of a radiological incident.
Collapse
Affiliation(s)
| | | | | | - Ewa D. Micewicz
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California, United States of America
| | - Josephine A. Ratikan
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California, United States of America
| | | | | | - Christine Nguyen
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California, United States of America
| | - Jason T. Lee
- Crump Institute for Molecular Imaging, University of California Los Angeles, Los Angeles, California, United States of America
| | - Tove Olafsen
- Crump Institute for Molecular Imaging, University of California Los Angeles, Los Angeles, California, United States of America
| | - Keisuke S. Iwamoto
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California, United States of America
| | - William H. McBride
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California, United States of America
| | - Dörthe Schaue
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California, United States of America
| | - Naresh Menon
- ChromoLogic LLC, Monrovia, California, United States of America
| |
Collapse
|
8
|
Sarkar PS, Ray NK, Pal MK, Baribaddala R, Agrawal A, Kashyap Y, Sinha A, Gadkari SC. Development of X-ray CCD camera based X-ray micro-CT system. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2017; 88:023702. [PMID: 28249518 DOI: 10.1063/1.4975376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Availability of microfocus X-ray sources and high resolution X-ray area detectors has made it possible for high resolution microtomography studies to be performed outside the purview of synchrotron. In this paper, we present the work towards the use of an external shutter on a high resolution microtomography system using X-ray CCD camera as a detector. During micro computed tomography experiments, the X-ray source is continuously ON and owing to the readout mechanism of the CCD detector electronics, the detector registers photons reaching it during the read-out period too. This introduces a shadow like pattern in the image known as smear whose direction is defined by the vertical shift register. To resolve this issue, the developed system has been incorporated with a synchronized shutter just in front of the X-ray source. This is positioned in the X-ray beam path during the image readout period and out of the beam path during the image acquisition period. This technique has resulted in improved data quality and hence the same is reflected in the reconstructed images.
Collapse
Affiliation(s)
- Partha S Sarkar
- Technical Physics Division, Bhabha Atomic Research Centre, Mumbai 400085, India
| | - N K Ray
- Technical Physics Division, Bhabha Atomic Research Centre, Mumbai 400085, India
| | - Manoj K Pal
- Technical Physics Division, Bhabha Atomic Research Centre, Mumbai 400085, India
| | - Ravi Baribaddala
- Technical Physics Division, Bhabha Atomic Research Centre, Mumbai 400085, India
| | - Ashish Agrawal
- Technical Physics Division, Bhabha Atomic Research Centre, Mumbai 400085, India
| | - Y Kashyap
- Technical Physics Division, Bhabha Atomic Research Centre, Mumbai 400085, India
| | - A Sinha
- Technical Physics Division, Bhabha Atomic Research Centre, Mumbai 400085, India
| | - S C Gadkari
- Technical Physics Division, Bhabha Atomic Research Centre, Mumbai 400085, India
| |
Collapse
|
9
|
Abstract
Thromboembolic disorders are a major cause of morbidity and mortality worldwide. The progress in noninvasive imaging techniques has led to the development of radionuclide imaging based on SPECT and PET approaches to observe molecular and cellular processes that may underlie the onset and progression of disease. The advantages of using normal and genetically modified small animal research have spurred the development of dedicated small animal imaging systems. Animal models of venous and arterial thrombosis are largely used and have improved our understanding of the etiology and pathogenesis of thrombosis. Here, we review the literature regarding nuclear imaging of thrombosis in mice and rats.
Collapse
Affiliation(s)
- Marie-Cécile Valéra
- a Inserm, U1048 and Université Toulouse III , I2MC, Toulouse , France.,b Faculté de Chirurgie Dentaire, Université de Toulouse III , Toulouse , France
| | - Bernard Payrastre
- a Inserm, U1048 and Université Toulouse III , I2MC, Toulouse , France.,c Laboratoire d'Hématologie CHU de Toulouse , Toulouse , France
| | - Olivier Lairez
- a Inserm, U1048 and Université Toulouse III , I2MC, Toulouse , France.,d Fédération des services de cardiologie, Département de Médecine Nucléaire Centre d'imagerie cardiaque, CHU de Toulouse , Toulouse , France
| |
Collapse
|
10
|
Poutiainen P, Jaronen M, Quintana FJ, Brownell AL. Precision Medicine in Multiple Sclerosis: Future of PET Imaging of Inflammation and Reactive Astrocytes. Front Mol Neurosci 2016; 9:85. [PMID: 27695400 PMCID: PMC5023680 DOI: 10.3389/fnmol.2016.00085] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2016] [Accepted: 08/30/2016] [Indexed: 12/29/2022] Open
Abstract
Non-invasive molecular imaging techniques can enhance diagnosis to achieve successful treatment, as well as reveal underlying pathogenic mechanisms in disorders such as multiple sclerosis (MS). The cooperation of advanced multimodal imaging techniques and increased knowledge of the MS disease mechanism allows both monitoring of neuronal network and therapeutic outcome as well as the tools to discover novel therapeutic targets. Diverse imaging modalities provide reliable diagnostic and prognostic platforms to better achieve precision medicine. Traditionally, magnetic resonance imaging (MRI) has been considered the golden standard in MS research and diagnosis. However, positron emission tomography (PET) imaging can provide functional information of molecular biology in detail even prior to anatomic changes, allowing close follow up of disease progression and treatment response. The recent findings support three major neuroinflammation components in MS: astrogliosis, cytokine elevation, and significant changes in specific proteins, which offer a great variety of specific targets for imaging purposes. Regardless of the fact that imaging of astrocyte function is still a young field and in need for development of suitable imaging ligands, recent studies have shown that inflammation and astrocyte activation are related to progression of MS. MS is a complex disease, which requires understanding of disease mechanisms for successful treatment. PET is a precise non-invasive imaging method for biochemical functions and has potential to enhance early and accurate diagnosis for precision therapy of MS. In this review we focus on modulation of different receptor systems and inflammatory aspect of MS, especially on activation of glial cells, and summarize the recent findings of PET imaging in MS and present the most potent targets for new biomarkers with the main focus on experimental MS research.
Collapse
Affiliation(s)
- Pekka Poutiainen
- Athinoula A Martinos Biomedical Imaging Center, Department of Radiology, Massachusetts General Hospital, Harvard Medical SchoolCharlestown, MA, USA
| | - Merja Jaronen
- Ann Romney Center for Neurologic Diseases, Brigham and Women's Hospital, Harvard Medical SchoolBoston, MA, USA
| | - Francisco J. Quintana
- Ann Romney Center for Neurologic Diseases, Brigham and Women's Hospital, Harvard Medical SchoolBoston, MA, USA
| | - Anna-Liisa Brownell
- Athinoula A Martinos Biomedical Imaging Center, Department of Radiology, Massachusetts General Hospital, Harvard Medical SchoolCharlestown, MA, USA
| |
Collapse
|
11
|
Ashton JR, West JL, Badea CT. In vivo small animal micro-CT using nanoparticle contrast agents. Front Pharmacol 2015; 6:256. [PMID: 26581654 PMCID: PMC4631946 DOI: 10.3389/fphar.2015.00256] [Citation(s) in RCA: 99] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2015] [Accepted: 10/19/2015] [Indexed: 12/12/2022] Open
Abstract
Computed tomography (CT) is one of the most valuable modalities for in vivo imaging because it is fast, high-resolution, cost-effective, and non-invasive. Moreover, CT is heavily used not only in the clinic (for both diagnostics and treatment planning) but also in preclinical research as micro-CT. Although CT is inherently effective for lung and bone imaging, soft tissue imaging requires the use of contrast agents. For small animal micro-CT, nanoparticle contrast agents are used in order to avoid rapid renal clearance. A variety of nanoparticles have been used for micro-CT imaging, but the majority of research has focused on the use of iodine-containing nanoparticles and gold nanoparticles. Both nanoparticle types can act as highly effective blood pool contrast agents or can be targeted using a wide variety of targeting mechanisms. CT imaging can be further enhanced by adding spectral capabilities to separate multiple co-injected nanoparticles in vivo. Spectral CT, using both energy-integrating and energy-resolving detectors, has been used with multiple contrast agents to enable functional and molecular imaging. This review focuses on new developments for in vivo small animal micro-CT using novel nanoparticle probes applied in preclinical research.
Collapse
Affiliation(s)
- Jeffrey R Ashton
- Department of Biomedical Engineering, Duke University, Durham NC, USA ; Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Durham NC, USA
| | - Jennifer L West
- Department of Biomedical Engineering, Duke University, Durham NC, USA
| | - Cristian T Badea
- Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Durham NC, USA
| |
Collapse
|
12
|
Clark DP, Badea CT. Micro-CT of rodents: state-of-the-art and future perspectives. Phys Med 2014; 30:619-34. [PMID: 24974176 PMCID: PMC4138257 DOI: 10.1016/j.ejmp.2014.05.011] [Citation(s) in RCA: 134] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2014] [Revised: 05/15/2014] [Accepted: 05/28/2014] [Indexed: 02/06/2023] Open
Abstract
Micron-scale computed tomography (micro-CT) is an essential tool for phenotyping and for elucidating diseases and their therapies. This work is focused on preclinical micro-CT imaging, reviewing relevant principles, technologies, and applications. Commonly, micro-CT provides high-resolution anatomic information, either on its own or in conjunction with lower-resolution functional imaging modalities such as positron emission tomography (PET) and single-photon emission computed tomography (SPECT). More recently, however, advanced applications of micro-CT produce functional information by translating clinical applications to model systems (e.g., measuring cardiac functional metrics) and by pioneering new ones (e.g. measuring tumor vascular permeability with nanoparticle contrast agents). The primary limitations of micro-CT imaging are the associated radiation dose and relatively poor soft tissue contrast. We review several image reconstruction strategies based on iterative, statistical, and gradient sparsity regularization, demonstrating that high image quality is achievable with low radiation dose given ever more powerful computational resources. We also review two contrast mechanisms under intense development. The first is spectral contrast for quantitative material discrimination in combination with passive or actively targeted nanoparticle contrast agents. The second is phase contrast which measures refraction in biological tissues for improved contrast and potentially reduced radiation dose relative to standard absorption imaging. These technological advancements promise to develop micro-CT into a commonplace, functional and even molecular imaging modality.
Collapse
Affiliation(s)
- D P Clark
- Center for In Vivo Microscopy, Department of Radiology, Duke University Medical Center, Box 3302, Durham, NC 27710, USA
| | - C T Badea
- Center for In Vivo Microscopy, Department of Radiology, Duke University Medical Center, Box 3302, Durham, NC 27710, USA.
| |
Collapse
|
13
|
Li C, Martínez-Dávalos A, Cherry SR. Numerical simulation of x-ray luminescence optical tomography for small-animal imaging. JOURNAL OF BIOMEDICAL OPTICS 2014; 19:046002. [PMID: 24695846 PMCID: PMC3973658 DOI: 10.1117/1.jbo.19.4.046002] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2013] [Revised: 02/27/2014] [Accepted: 03/03/2014] [Indexed: 05/20/2023]
Abstract
X-ray luminescence optical tomography (XLOT) is an emerging hybrid imaging modality in which x-ray excitable particles (phosphor particles) emit optical photons when stimulated with a collimated x-ray beam. XLOT can potentially combine the high sensitivity of optical imaging with the high spatial resolution of x-ray imaging. For reconstruction of XLOT data, we compared two reconstruction algorithms, conventional filtered backprojection (FBP) and a new algorithm, x-ray luminescence optical tomography with excitation priors (XLOT-EP), in which photon propagation is modeled with the diffusion equation and the x-ray beam positions are used as reconstruction priors. Numerical simulations based on dose calculations were used to validate the proposed XLOT imaging system and the reconstruction algorithms. Simulation results showed nanoparticle concentrations reconstructed with XLOT-EP are much less dependent on scan depth than those obtained with FBP. Measurements at just two orthogonal projections are sufficient for XLOT-EP to reconstruct an XLOT image for simple source distributions. The heterogeneity of x-ray energy deposition is included in the XLOT-EP reconstruction and improves the reconstruction accuracy, suggesting that there is a need to calculate the x-ray energy distribution for experimental XLOT imaging.
Collapse
Affiliation(s)
- Changqing Li
- University of California, School of Engineering, Merced, Merced, California 95343
- Address all correspondence to: Changqing Li, E-mail:
| | - Arnulfo Martínez-Dávalos
- Universidad Nacional Autónoma de México, Instituto de Física, A.P. 20-364, 01000 México D.F., Mexico
| | - Simon R. Cherry
- University of California, Department of Biomedical Engineering, Davis, Davis, California 95616
| |
Collapse
|
14
|
Ding H, Wu F. Image guided biodistribution and pharmacokinetic studies of theranostics. Am J Cancer Res 2012; 2:1040-53. [PMID: 23227121 PMCID: PMC3516836 DOI: 10.7150/thno.4652] [Citation(s) in RCA: 76] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2012] [Accepted: 06/17/2012] [Indexed: 11/05/2022] Open
Abstract
Image guided technique is playing an increasingly important role in the investigation of the biodistribution and pharmacokinetics of drugs or drug delivery systems in various diseases, especially cancers. Besides anatomical imaging modalities such as computed tomography (CT), magnetic resonance imaging (MRI), molecular imaging strategy including optical imaging, positron emission tomography (PET) and single-photon emission computed tomography (SPECT) will facilitate the localization and quantization of radioisotope or optical probe labeled nanoparticle delivery systems in the category of theranostics. The quantitative measurement of the bio-distribution and pharmacokinetics of theranostics in the fields of new drug/probe development, diagnosis and treatment process monitoring as well as tracking the brain-blood-barrier (BBB) breaking through by high sensitive imaging method, and the applications of the representative imaging modalities are summarized in this review.
Collapse
|
15
|
El Ali HH, Bodholdt RP, Jørgensen JT, Myschetzky R, Kjaer A. Importance of Attenuation Correction (AC) for Small Animal PET Imaging. Diagnostics (Basel) 2012; 2:42-51. [PMID: 26859397 PMCID: PMC4665554 DOI: 10.3390/diagnostics2040042] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2012] [Revised: 09/13/2012] [Accepted: 10/08/2012] [Indexed: 11/16/2022] Open
Abstract
UNLABELLED The purpose of this study was to investigate whether a correction for annihilation photon attenuation in small objects such as mice is necessary. The attenuation recovery for specific organs and subcutaneous tumors was investigated. A comparison between different attenuation correction methods was performed. METHODS Ten NMRI nude mice with subcutaneous implantation of human breast cancer cells (MCF-7) were scanned consecutively in small animal PET and CT scanners (MicroPET(TM) Focus 120 and ImTek's MicroCAT(TM) II). CT-based AC, PET-based AC and uniform AC methods were compared. RESULTS The activity concentration in the same organ with and without AC revealed an overall attenuation recovery of 9-21% for MAP reconstructed images, i.e., SUV without AC could underestimate the true activity at this level. For subcutaneous tumors, the attenuation was 13 ± 4% (9-17%), for kidneys 20 ± 1% (19-21%), and for bladder 18 ± 3% (15-21%). The FBP reconstructed images showed almost the same attenuation levels as the MAP reconstructed images for all organs. CONCLUSIONS The annihilation photons are suffering attenuation even in small subjects. Both PET-based and CT-based are adequate as AC methods. The amplitude of the AC recovery could be overestimated using the uniform map. Therefore, application of a global attenuation factor on PET data might not be accurate for attenuation correction.
Collapse
Affiliation(s)
- Henrik H El Ali
- Cluster for Molecular Imaging, Faculty of Health Sciences & Department of Clinical Physiology, Nuclear Medicine & PET, Rigshospitalet, University of Copenhagen, Blegdamsvej 3, Copenhagen DK-2200, Denmark.
| | - Rasmus Poul Bodholdt
- Cluster for Molecular Imaging, Faculty of Health Sciences & Department of Clinical Physiology, Nuclear Medicine & PET, Rigshospitalet, University of Copenhagen, Blegdamsvej 3, Copenhagen DK-2200, Denmark.
| | - Jesper Tranekjær Jørgensen
- Cluster for Molecular Imaging, Faculty of Health Sciences & Department of Clinical Physiology, Nuclear Medicine & PET, Rigshospitalet, University of Copenhagen, Blegdamsvej 3, Copenhagen DK-2200, Denmark.
| | - Rebecca Myschetzky
- Cluster for Molecular Imaging, Faculty of Health Sciences & Department of Clinical Physiology, Nuclear Medicine & PET, Rigshospitalet, University of Copenhagen, Blegdamsvej 3, Copenhagen DK-2200, Denmark.
| | - Andreas Kjaer
- Cluster for Molecular Imaging, Faculty of Health Sciences & Department of Clinical Physiology, Nuclear Medicine & PET, Rigshospitalet, University of Copenhagen, Blegdamsvej 3, Copenhagen DK-2200, Denmark.
| |
Collapse
|
16
|
Wang H, Stout DB, Taschereau R, Gu Z, Vu NT, Prout DL, Chatziioannou AF. MARS: a mouse atlas registration system based on a planar x-ray projector and an optical camera. Phys Med Biol 2012; 57:6063-77. [PMID: 22968224 DOI: 10.1088/0031-9155/57/19/6063] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
This paper introduces a mouse atlas registration system (MARS), composed of a stationary top-view x-ray projector and a side-view optical camera, coupled to a mouse atlas registration algorithm. This system uses the x-ray and optical images to guide a fully automatic co-registration of a mouse atlas with each subject, in order to provide anatomical reference for small animal molecular imaging systems such as positron emission tomography (PET). To facilitate the registration, a statistical atlas that accounts for inter-subject anatomical variations was constructed based on 83 organ-labeled mouse micro-computed tomography (CT) images. The statistical shape model and conditional Gaussian model techniques were used to register the atlas with the x-ray image and optical photo. The accuracy of the atlas registration was evaluated by comparing the registered atlas with the organ-labeled micro-CT images of the test subjects. The results showed excellent registration accuracy of the whole-body region, and good accuracy for the brain, liver, heart, lungs and kidneys. In its implementation, the MARS was integrated with a preclinical PET scanner to deliver combined PET/MARS imaging, and to facilitate atlas-assisted analysis of the preclinical PET images.
Collapse
Affiliation(s)
- Hongkai Wang
- Department of Molecular and Medical Pharmacology, Crump Institute for Molecular Imaging, UCLA, Los Angeles, CA, USA.
| | | | | | | | | | | | | |
Collapse
|
17
|
|
18
|
Foster FS, Brown AS. Microultrasound and its application to longitudinal studies of mouse eye development and disease. Cold Spring Harb Protoc 2012; 2012:494-503. [PMID: 22474659 DOI: 10.1101/pdb.prot068544] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Microultrasound imaging is a flexible high-resolution real-time in vivo imaging modality based on the transmission and the reception of ultrasound waves. Because of its high temporal (>250 Hz) and spatial (30-150 µm) resolutions and the noninvasive nature of ultrasound, microultrasound is used extensively in preclinical research to monitor functional and dynamic phenotypic changes in small animal models. Its ability to perform in vivo longitudinal monitoring of development, pathology, and therapeutic effectiveness is particularly advantageous. This article reviews the technology and the applications of high-frequency microultrasound for the study of mouse eye development from embryonic day E11.5 to postnatal day P16. Procedures for animal handling and scanning are given, and applications are described in the context of ocular development and disease. Quantitative analysis of the growth kinetics of the lens and the orbit is discussed. In addition, mouse models of retinoblastoma and glaucoma are followed as a function of disease progression to reveal their associated morphological and functional traits. Microultrasound is performed with high-frequency imaging equipment (from VisualSonics) operating at center frequencies between 15 and 50 MHz. These instruments provide both anatomical imaging as well as functional and molecular analyses of the living mouse.
Collapse
|
19
|
Cheng-Liao J, Qi J. PET image reconstruction with anatomical edge guided level set prior. Phys Med Biol 2011; 56:6899-918. [PMID: 21983558 DOI: 10.1088/0031-9155/56/21/009] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Acquiring both anatomical and functional images during one scan, PET/CT systems improve the ability to detect and localize abnormal uptakes. In addition, CT images provide anatomical boundary information that can be used to regularize positron emission tomography (PET) images. Here we propose a new approach to maximum a posteriori reconstruction of PET images with a level set prior guided by anatomical edges. The image prior models both the smoothness of PET images and the similarity between functional boundaries in PET and anatomical boundaries in CT. Level set functions (LSFs) are used to represent smooth and closed functional boundaries. The proposed method does not assume an exact match between PET and CT boundaries. Instead, it encourages similarity between the two boundaries, while allowing different region definition in PET images to accommodate possible signal and position mismatch between functional and anatomical images. While the functional boundaries are guaranteed to be closed by the LSFs, the proposed method does not require closed anatomical boundaries and can utilize incomplete edges obtained from an automatic edge detection algorithm. We conducted computer simulations to evaluate the performance of the proposed method. Two digital phantoms were constructed based on the Digimouse data and a human CT image, respectively. Anatomical edges were extracted automatically from the CT images. Tumors were simulated in the PET phantoms with different mismatched anatomical boundaries. Compared with existing methods, the new method achieved better bias-variance performance. The proposed method was also applied to real mouse data and achieved higher contrast than other methods.
Collapse
Affiliation(s)
- Jinxiu Cheng-Liao
- Department of Biomedical Engineering, University of California, Davis, CA 95616, USA
| | | |
Collapse
|
20
|
Cheng D, Wang Y, Liu X, Pretorius PH, Liang M, Rusckowski M, Hnatowich DJ. Comparison of 18F PET and 99mTc SPECT imaging in phantoms and in tumored mice. Bioconjug Chem 2011; 21:1565-70. [PMID: 20681508 DOI: 10.1021/bc1001467] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Our objective was to compare the performance of a micro-single photon emission computed tomography (micro-SPECT) with that of a micro-positron emission tomography (microPET) in a Her2+ tumored mice using an anti-Her2 nanoparticle radiolabeled with (99m)Tc and (18)F. Camera performance was first compared using phantoms; then a tumored mouse administered the (99m)Tc-nanoparticle was imaged on a Bioscan NanoSPECT/CT, while another tumored mouse received the identical nanoparticle, labeled now with (18)F, and was imaged on a Philips Mosaic HP PET camera. The nanoparticle was radiolabeled with (99m)Tc via MAG(3) chelation and with (18)F via SFB as an intermediate. Phantom imaging showed that the resolution of the SPECT camera was clearly superior, but even with 4 heads and multipinhole collimators, detection sensitivity was 15-fold lower. Radiolabeling of the nanoparticle by chelation with (99m)Tc was considerably easier and safer than manual covalent attachment of (18)F. Both cameras provided accurate quantitation of radioactivity over a broad range. In conclusion, when deciding between (99m)Tc vs (18)F, an advantage rests with the chelation of (99m)Tc over covalent attachment of (18)F, achieved manually or otherwise, but with these small animal cameras, this choice also results in trading lower sensitivity for higher resolution.
Collapse
Affiliation(s)
- Dengfeng Cheng
- Division of Nuclear Medicine, Department of Radiology, University of Massachusetts Medical School, Worcester, MA 01655, USA
| | | | | | | | | | | | | |
Collapse
|
21
|
Sandhu GS, Solorio L, Broome AM, Salem N, Kolthammer J, Shah T, Flask C, Duerk JL. Whole animal imaging. WILEY INTERDISCIPLINARY REVIEWS-SYSTEMS BIOLOGY AND MEDICINE 2010; 2:398-421. [PMID: 20836038 DOI: 10.1002/wsbm.71] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Translational research plays a vital role in understanding the underlying pathophysiology of human diseases, and hence development of new diagnostic and therapeutic options for their management. After creating an animal disease model, pathophysiologic changes and effects of a therapeutic intervention on them are often evaluated on the animals using immunohistologic or imaging techniques. In contrast to the immunohistologic techniques, the imaging techniques are noninvasive and hence can be used to investigate the whole animal, oftentimes in a single exam which provides opportunities to perform longitudinal studies and dynamic imaging of the same subject, and hence minimizes the experimental variability, requirement for the number of animals, and the time to perform a given experiment. Whole animal imaging can be performed by a number of techniques including x-ray computed tomography, magnetic resonance imaging, ultrasound imaging, positron emission tomography, single photon emission computed tomography, fluorescence imaging, and bioluminescence imaging, among others. Individual imaging techniques provide different kinds of information regarding the structure, metabolism, and physiology of the animal. Each technique has its own strengths and weaknesses, and none serves every purpose of image acquisition from all regions of an animal. In this review, a broad overview of basic principles, available contrast mechanisms, applications, challenges, and future prospects of many imaging techniques employed for whole animal imaging is provided. Our main goal is to briefly describe the current state of art to researchers and advanced students with a strong background in the field of animal research.
Collapse
Affiliation(s)
- Gurpreet Singh Sandhu
- Department of Biomedical Engineering, Case Center of Imaging Research, Case Western Reserve University, Cleveland, OH 44106, USA
| | - Luis Solorio
- Department of Biomedical Engineering, Case Center of Imaging Research, Case Western Reserve University, Cleveland, OH 44106, USA
| | - Ann-Marie Broome
- Department of Biomedical Engineering, Case Center of Imaging Research, Case Western Reserve University, Cleveland, OH 44106, USA
| | - Nicolas Salem
- Department of Biomedical Engineering, Case Center of Imaging Research, Case Western Reserve University, Cleveland, OH 44106, USA
| | - Jeff Kolthammer
- Department of Biomedical Engineering, Case Center of Imaging Research, Case Western Reserve University, Cleveland, OH 44106, USA
| | - Tejas Shah
- Department of Biomedical Engineering, Case Center of Imaging Research, Case Western Reserve University, Cleveland, OH 44106, USA
| | - Chris Flask
- Department of Biomedical Engineering, Case Center of Imaging Research, Case Western Reserve University, Cleveland, OH 44106, USA
| | - Jeffrey L Duerk
- Department of Biomedical Engineering, Case Center of Imaging Research, Case Western Reserve University, Cleveland, OH 44106, USA
| |
Collapse
|
22
|
Lee CL, Wahnishe H, Sayre GA, Cho HM, Kim HJ, Hernandez-Pampaloni M, Hawkins RA, Dannoon SF, VanBrocklin HF, Itsara M, Weiss WA, Yang X, Haas-Kogan DA, Matthay KK, Seo Y. Radiation dose estimation using preclinical imaging with 124I-metaiodobenzylguanidine (MIBG) PET. Med Phys 2010; 37:4861-7. [PMID: 20964203 PMCID: PMC2937055 DOI: 10.1118/1.3480965] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2010] [Revised: 07/28/2010] [Accepted: 07/29/2010] [Indexed: 11/07/2022] Open
Abstract
PURPOSE A pretherapy 124I-metaiodobenzylguanidine (MIBG) positron emission tomography (PET)/computed tomography (CT) provides a potential method to estimate radiation dose to normal organs, as well as tumors prior to 131I-MIBG treatment of neuroblastoma or pheochromocytoma. The aim of this work was to estimate human-equivalent internal radiation dose of 124I-MIBG using PET/CT data in a murine xenograft model. METHODS Athymic mice subcutaneously implanted with NB1691 cells that express high levels of human norepinephrine transporter (n = 4) were imaged using small animal microPET/CT over 96 h (approximate imaging time points: 0.5, 2, 24, 52, and 96 h) after intravenous administration of 3.07-4.84 MBq of 124I-MIBG via tail vein. The tumors did not accumulate 124I-MIBG to a detectable level. All four animals were considered as control and organ radiation dosimetry was performed. Volumes of interest were drawn on the coregistered CT images for thyroid, heart, lung, liver, kidney, and bladder, and transferred to PET images to obtain pharmacokinetic data. Based on tabulated organ mass distributions for both mice and adult male human, preclinical pharmacokinetic data were extrapolated to their human-equivalent values. Radiation dose estimations for different age groups were performed using the OLINDA/EXM software with modified tissue weighting factors in the recent International Commission on Radiological Protection (ICRP) Publication 103. RESULTS The mean effective dose from 124I-MIBG using weighting factors from ICRP 103 to the adult male was estimated at 0.25 mSv/MBq. In different age groups, effective doses using values from ICRP 103 were estimated as follows: Adult female: 0.34, 15-yr-old: 0.39 mSv/MBq, 10-yr-old: 0.58 mSv/MBq, 5-yr-old: 1.03 mSv/MBq, 1-yr-old: 1.92 mSv/MBq, and newborn: 3.75 mSv/ MBq. For comparison, the reported effective dose equivalent of 124I-NaI for adult male (25% thyroid uptake, MIRD Dose Estimate Report No. 5) was 6.5 mSv/MBq. CONCLUSIONS The authors estimated human-equivalent internal radiation dose of 124I-MIBG using preclinical imaging data. As a reference, the effective dose estimation showed that 124I-MIBG would deliver less radiation dose than 124I-NaI, a radiotracer already being used in patients with thyroid cancer.
Collapse
Affiliation(s)
- Chang-Lae Lee
- Department of Radiology and Biomedical Imaging, UCSF Physics Research Laboratory, University of California, San Francisco, San Francisco, California 94143, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Kuntz J, Dinkel J, Zwick S, Bäuerle T, Grasruck M, Kiessling F, Gupta R, Semmler W, Bartling SH. Fully automated intrinsic respiratory and cardiac gating for small animal CT. Phys Med Biol 2010; 55:2069-85. [PMID: 20299735 DOI: 10.1088/0031-9155/55/7/018] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A fully automated, intrinsic gating algorithm for small animal cone-beam CT is described and evaluated. A parameter representing the organ motion, derived from the raw projection images, is used for both cardiac and respiratory gating. The proposed algorithm makes it possible to reconstruct motion-corrected still images as well as to generate four-dimensional (4D) datasets representing the cardiac and pulmonary anatomy of free-breathing animals without the use of electrocardiogram (ECG) or respiratory sensors. Variation analysis of projections from several rotations is used to place a region of interest (ROI) on the diaphragm. The ROI is cranially extended to include the heart. The centre of mass (COM) variation within this ROI, the filtered frequency response and the local maxima are used to derive a binary motion-gating parameter for phase-sensitive gated reconstruction. This algorithm was implemented on a flat-panel-based cone-beam CT scanner and evaluated using a moving phantom and animal scans (seven rats and eight mice). Volumes were determined using a semiautomatic segmentation. In all cases robust gating signals could be obtained. The maximum volume error in phantom studies was less than 6%. By utilizing extrinsic gating via externally placed cardiac and respiratory sensors, the functional parameters (e.g. cardiac ejection fraction) and image quality were equivalent to this current gold standard. This algorithm obviates the necessity of both gating hardware and user interaction. The simplicity of the proposed algorithm enables adoption in a wide range of small animal cone-beam CT scanners.
Collapse
Affiliation(s)
- J Kuntz
- Department of Medical Physics in Radiology, German Cancer Research Center, Heidelberg, Germany.
| | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Papathanassiou D, Bruna-Muraille C, Liehn JC, Nguyen TD, Curé H. Positron Emission Tomography in oncology: Present and future of PET and PET/CT. Crit Rev Oncol Hematol 2009; 72:239-54. [DOI: 10.1016/j.critrevonc.2008.10.006] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2008] [Revised: 09/30/2008] [Accepted: 10/14/2008] [Indexed: 01/01/2023] Open
|
25
|
Yang Y, Wu Y, Cherry SR. Investigation of Depth of Interaction Encoding for a Pixelated LSO Array with a Single Multi-Channel PMT. IEEE TRANSACTIONS ON NUCLEAR SCIENCE 2009; 56:2594-2599. [PMID: 20046796 PMCID: PMC2799034 DOI: 10.1109/tns.2009.2016094] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
A new approach to depth of interaction (DOI) encoding for a pixelated LSO array using a single multi-channel PMT was investigated. In this method the DOI information was estimated by taking advantage of optical crosstalk between LSO elements and examining the standard deviation (spread) of signals on all channels of the PMT. Unpolished and polished 6×6 LSO arrays with a crystal size of 1.3×1.3×20 mm(3) were evaluated on a Hamamatsu H7546 64-channel PMT. The arrays were placed on the center of the PMT and the central 16 channels of the PMT were individually read out and digitized. For the unpolished array, all crystals were resolved in the flood histogram. An average DOI resolution of 8 mm was obtained. The energy resolution was ∼25% after the signal amplitude was corrected using the measured DOI information. For the polished array, the flood histogram was superior to the unpolished array, however no DOI information could be measured. Using unpolished crystals, this method could be a practical way to achieve limited DOI information in PET detectors. The standard deviation of all PMT channels can be readily obtained using a resistor network. Only five signals (four signals to determine the x-y position and one signal measuring the standard deviation) need to be digitized, and this method only requires a single photon detector to read out the array. Unlike phoswich detectors, the method does not require segmenting the scintillator array into layers. The measured DOI resolution was much worse than that obtained with the dual-ended readout method, however, it was similar to that obtained with a two-layer phoswich detector.
Collapse
Affiliation(s)
- Yongfeng Yang
- Department of Biomedical Engineering, University of California-Davis, CA 95616 USA
| | | | | |
Collapse
|
26
|
Mancini M, Vergara E, Salvatore G, Greco A, Troncone G, Affuso A, Liuzzi R, Salerno P, Scotto di Santolo M, Santoro M, Brunetti A, Salvatore M. Morphological ultrasound microimaging of thyroid in living mice. Endocrinology 2009; 150:4810-5. [PMID: 19589864 DOI: 10.1210/en.2009-0417] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
The objective of the study was to explore high-frequency ultrasound (HFUS) for noninvasive microimaging of thyroid in living mice. Thyroid examination was performed by HFUS in 10 normal C57BL/6 mice, eight mice treated by propylthiouracil, and 22 Tg-TRK-T1 transgenic mice. The dimension of the gland and the presence of nodules were evaluated. Nodules were classified as malignant (hypoechogenicity, poorly defined margins, internal microcalcification, irregular shapes, and extra glandular extension) or not, and the findings were compared with histological data. Thyroid images were successfully obtained in all the animals analyzed. Normal thyroid reached a volume of 4.92 microl (range 2.11-4.92 microl). Mice with propylthiouracil-induced goiter showed diffuse thyroid enlargement (median volume 6.67 microl, range 4.09-8.82 microl). In 19 of 22 Tg-TRK-T1 mice (86%), HFUS identified a nodular process (the smallest detected nodule had a diameter of 0.46 mm). Eleven nodules were classified as malignant and eight as benign. Compared with histological analysis, HFUS showed a sensitivity of 100% in the detection of thyroid nodules and a specificity of 60% (two of the nodules identified by HFUS were not confirmed at the histology). The specificity and sensitivity of HFUS in predicting the malignancy of the thyroid nodules were 83 and 91%, respectively. Thus, HFUS is an accurate imaging modality that can potentially replace more invasive techniques, and, therefore, it represents a significant advancement in phenotypic assessment of mouse models of thyroid cancer.
Collapse
Affiliation(s)
- Marcello Mancini
- Institute of Biostructure and Bioimaging, Italian National Research Council, Institute of Diagnostic and Nuclear Development SDN, Università Federico II, Naples, Italy.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Cone beam micro-CT system for small animal imaging and performance evaluation. Int J Biomed Imaging 2009; 2009:960573. [PMID: 19794829 PMCID: PMC2754077 DOI: 10.1155/2009/960573] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2009] [Revised: 05/22/2009] [Accepted: 07/04/2009] [Indexed: 12/28/2022] Open
Abstract
A prototype cone-beam micro-CT system for small animal imaging has been developed by our group recently, which consists of a microfocus X-ray source, a three-dimensional programmable stage with object holder, and a flat-panel X-ray detector. It has a large field of view (FOV), which can acquire the whole body imaging of a normal-size mouse in a single scan which usually takes about several minutes or tens of minutes. FDK method is adopted for 3D reconstruction with Graphics Processing Unit (GPU) acceleration. In order to reconstruct images with high spatial resolution and low artifacts, raw data preprocessing and geometry calibration are implemented before reconstruction. A method which utilizes a wire phantom to estimate the residual horizontal offset of the detector is proposed, and 1D point spread function is used to assess the performance of geometric calibration quantitatively. System spatial resolution, image uniformity and noise, and low contrast resolution have been studied. Mouse images with and without contrast agent are illuminated in this paper. Experimental results show that the system is suitable for small animal imaging and is adequate to provide high-resolution anatomic information for bioluminescence tomography to build a dual modality system.
Collapse
|
28
|
Zaidi H, Vees H, Wissmeyer M. Molecular PET/CT imaging-guided radiation therapy treatment planning. Acad Radiol 2009; 16:1108-33. [PMID: 19427800 DOI: 10.1016/j.acra.2009.02.014] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2008] [Revised: 02/11/2009] [Accepted: 02/19/2009] [Indexed: 01/01/2023]
Abstract
The role of positron emission tomography (PET) during the past decade has evolved rapidly from that of a pure research tool to a methodology of enormous clinical potential. (18)F-fluorodeoxyglucose (FDG)-PET is currently the most widely used probe in the diagnosis, staging, assessment of tumor response to treatment, and radiation therapy planning because metabolic changes generally precede the more conventionally measured parameter of change in tumor size. Data accumulated rapidly during the last decade, thus validating the efficacy of FDG imaging and many other tracers in a wide variety of malignant tumors with sensitivities and specificities often in the high 90 percentile range. As a result, PET/computed tomography (CT) had a significant impact on the management of patients because it obviated the need for further evaluation, guided further diagnostic procedures, and assisted in planning therapy for a considerable number of patients. On the other hand, the progress in radiation therapy technology has been enormous during the last two decades, now offering the possibility to plan highly conformal radiation dose distributions through the use of sophisticated beam targeting techniques such as intensity-modulated radiation therapy (IMRT) using tomotherapy, volumetric modulated arc therapy, and many other promising technologies for sculpted three-dimensional (3D) dose distribution. The foundation of molecular imaging-guided radiation therapy lies in the use of advanced imaging technology for improved definition of tumor target volumes, thus relating the absorbed dose information to image-based patient representations. This review documents technological advancements in the field concentrating on the conceptual role of molecular PET/CT imaging in radiation therapy treatment planning and related image processing issues with special emphasis on segmentation of medical images for the purpose of defining target volumes. There is still much more work to be done and many of the techniques reviewed are themselves not yet widely implemented in clinical settings.
Collapse
|
29
|
Lage E, Vaquero JJ, Sisniega A, España S, Tapias G, Abella M, Rodríguez-Ruano A, Ortuño JE, Udías A, Desco M. Design and performance evaluation of a coplanar multimodality scanner for rodent imaging. Phys Med Biol 2009; 54:5427-41. [PMID: 19700817 DOI: 10.1088/0031-9155/54/18/005] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
This work reports on the development and performance evaluation of the VrPET/CT, a new multimodality scanner with coplanar geometry for in vivo rodent imaging. The scanner design is based on a partial-ring PET system and a small-animal CT assembled on a rotatory gantry without axial displacement between the geometric centers of both fields of view (FOV). We report on the PET system performance based on the NEMA NU-4 protocol; the performance characteristics of the CT component are not included herein. The accuracy of inter-modality alignment and the imaging capability of the whole system are also evaluated on phantom and animal studies. Tangential spatial resolution of PET images ranged between 1.56 mm at the center of the FOV and 2.46 at a radial offset of 3.5 cm. The radial resolution varies from 1.48 mm to 1.88 mm, and the axial resolution from 2.34 mm to 3.38 mm for the same positions. The energy resolution was 16.5% on average for the entire system. The absolute coincidence sensitivity is 2.2% for a 100-700 keV energy window with a 3.8 ns coincident window. The scatter fraction values for the same settings were 11.45% for a mouse-sized phantom and 23.26% for a rat-sized phantom. The peak noise equivalent count rates were also evaluated for those phantoms obtaining 70.8 kcps at 0.66 MBq/cc and 31.5 kcps at 0.11 MBq/cc, respectively. The accuracy of inter-modality alignment is below half the PET resolution, and the image quality of biological specimens agrees with measured performance parameters. The assessment presented in this study shows that the VrPET/CT system is a good performance small-animal imager, while the cost derived from a partial ring detection system is substantially reduced as compared with a full-ring PET tomograph.
Collapse
Affiliation(s)
- E Lage
- Unidad de Medicina y Cirugía Experimental, Hospital General Universitario Gregorio Marañón, Madrid, Spain.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Abstract
Multimodality small-animal molecular imaging has become increasingly important as transgenic and knockout mice are produced to model human diseases. With the ever-increasing number and importance of human disease models, particularly in rodents (mice and rats), the ability of high-resolution multimodality molecular imaging instrumentation to contribute unique information is becoming more common and necessary. Multimodality imaging with high spatial resolution and good sensitivity, which combines modalities and records sequentially or simultaneously complementary information, offers many advantages in certain research experiments. This article discusses the current trends and new horizons in preclinical multimodality imaging in-vivo and its role in biomedical research.
Collapse
Affiliation(s)
- David B Stout
- Crump Institute for Molecular Imaging, Department of Molecular and Medical Pharmacology, The David Geffen School of Medicine at UCLA, 570 Westwood Plaza, CNSI Building, Room 2151, Los Angeles, CA 90095, USA
| | - Habib Zaidi
- Division of Nuclear Medicine, Geneva University Hospital, CH-1211 Geneva, Switzerland.
| |
Collapse
|
31
|
Olcott PD, Peng H, Levin CS. Novel Electro-Optical Coupling Technique for Magnetic Resonance-Compatible Positron Emission Tomography Detectors. Mol Imaging 2009. [DOI: 10.2310/7290.2009.00012] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Affiliation(s)
- Peter D. Olcott
- From the Department of Bioengineering and the Molecular Imaging Program, Department of Radiology, Stanford University, Stanford, CA
| | - Hao Peng
- From the Department of Bioengineering and the Molecular Imaging Program, Department of Radiology, Stanford University, Stanford, CA
| | - Craig S. Levin
- From the Department of Bioengineering and the Molecular Imaging Program, Department of Radiology, Stanford University, Stanford, CA
| |
Collapse
|
32
|
Papathanassiou D, Liehn JC. The growing development of multimodality imaging in oncology. Crit Rev Oncol Hematol 2008; 68:60-5. [PMID: 18765183 DOI: 10.1016/j.critrevonc.2008.04.003] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2008] [Accepted: 04/16/2008] [Indexed: 11/16/2022] Open
Abstract
The first decade of the century has been the beginning of an era of new practice in daily medical imaging, that is the multimodality involving functional or metabolic imaging brought by nuclear medicine techniques directly associated with anatomical information brought by CT (Computed X-Ray Tomography) devices combined with nuclear medicine detectors. PET (Positron Emission Tomography)/CT and SPECT (Single Photon Emission Computed Tomography)/CT are now established to further increase the interest of PET and SPECT, thanks to improved localization of the pathologic processes, and in many instances thanks to a gain in specificity. An even better use of the combined information will necessitate redefining some protocols and indications, and the future will probably see the continued development of multimodality imaging in practice. Besides the combination with CT, another modality is expected in the future: PET/MRI (Magnetic Resonance Imaging).
Collapse
|
33
|
Badea CT, Drangova M, Holdsworth DW, Johnson GA. In vivo small-animal imaging using micro-CT and digital subtraction angiography. Phys Med Biol 2008; 53:R319-50. [PMID: 18758005 DOI: 10.1088/0031-9155/53/19/r01] [Citation(s) in RCA: 170] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Small-animal imaging has a critical role in phenotyping, drug discovery and in providing a basic understanding of mechanisms of disease. Translating imaging methods from humans to small animals is not an easy task. The purpose of this work is to review in vivo x-ray based small-animal imaging, with a focus on in vivo micro-computed tomography (micro-CT) and digital subtraction angiography (DSA). We present the principles, technologies, image quality parameters and types of applications. We show that both methods can be used not only to provide morphological, but also functional information, such as cardiac function estimation or perfusion. Compared to other modalities, x-ray based imaging is usually regarded as being able to provide higher throughput at lower cost and adequate resolution. The limitations are usually associated with the relatively poor contrast mechanisms and potential radiation damage due to ionizing radiation, although the use of contrast agents and careful design of studies can address these limitations. We hope that the information will effectively address how x-ray based imaging can be exploited for successful in vivo preclinical imaging.
Collapse
Affiliation(s)
- C T Badea
- Center for In Vivo Microscopy, Department of Radiology, Duke University, Durham, NC 27710, USA
| | | | | | | |
Collapse
|
34
|
|
35
|
Abstract
Molecular imaging using PET has evolved from a vigorous academic field into the clinical arena. Considerable advances have been made in the design of high-resolution standalone PET and combined PET/CT units dedicated to clinical whole-body scanning. Likewise, much worthwhile research focused on the development of quantitative imaging protocols incorporating accurate data correction techniques and sophisticated image reconstruction algorithms. Since its inception, photon attenuation in biological tissues has been identified as the most important physical degrading factor affecting PET image quality and quantitative accuracy. Various strategies have been devised to determine an accurate attenuation map to enable correction for nonlinear photon attenuation in whole-body PET studies. This article presents the physical and methodological basis of photon attenuation and summarizes state-of-the-art developments in algorithms used to derive the attenuation map aiming at accurate attenuation compensation of PET data. Future prospects, research trends, and challenges are identified, and directions for future research are discussed.
Collapse
Affiliation(s)
- Habib Zaidi
- Division of Nuclear Medicine, Geneva University Hospital, CH-1211 Geneva 4, Switzerland.
| | | | - Abass Alavi
- Division of Nuclear Medicine, Department of Radiology, Hospital of the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104, USA
| |
Collapse
|
36
|
|