Trivellato S, Caricato P, Pellegrini R, Daniotti MC, Bianchi S, Bordigoni B, Carminati S, Faccenda V, Panizza D, Montanari G, Arcangeli S, De Ponti E. Lexicographic optimization-based planning for stereotactic radiosurgery of brain metastases. Radiother Oncol 2024; 196:110308. [PMID: 38677330 DOI: 10.1016/j.radonc.2024.110308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 04/19/2024] [Accepted: 04/19/2024] [Indexed: 04/29/2024]
Abstract
AIM To validate a fully-automated lexicographic optimization-planning system (mCycle, Elekta) for single-(SL) and multiple-(ML, up to 4 metastases) lesions in intracranial stereotactic radiosurgery (SRS, 21 Gy, single fraction). METHODS A pre-determined priority list, Wish-List (WL), represents a dialogue between planner and clinician, establishing strict constraints and pursuing objectives. In order to satisfy the clinical protocol without manual intervention, four patients were required to tweak and fine-tune each WL (SLp, MLp) for coplanar arcs. Thirty-five testing plans (20 SLp, 15 MLp) were automatically re-planned (mCP). Automatic and manual plans were compared including dose constraints, conformality, modulation complexity score (MCS), delivery time, and local gamma analysis (2%/2 mm). To ensure plan clinical acceptability, two radiation oncologists conducted an independent blind plan choice. RESULTS Each WL-tuning took 3 days. Estimated median manual plans and mCP calculation time were 8 and 3 h, respectively. Significant increases in SLp and MLp target coverage and conformity were registered. mCP showed a not significant and clinically acceptable higher median brain V12Gy. SLp registered a -5.8% MU decrease with comparable median delivery time (MP 2.0 min, mCP 1.9 min) while MLp showed a +9.8% MU increase and longer delivery time (MP 3.5 min, mCP 4.4 min). mCP MCS resulted significantly higher without affecting gamma passing rates. At blind choice, mCP were preferred in the majority of cases. CONCLUSIONS Lexicographic optimization produced acceptable SRS plans with coplanar arcs significantly reducing the overall planning time in cases with up to 4 brain metastases. These planning improvements suggest further investigations by setting high-quality non-coplanar arc plans as a reference.
Collapse
Affiliation(s)
- Sara Trivellato
- Medical Physics Department, Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy
| | - Paolo Caricato
- Medical Physics Department, Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy; Department of Physics, University of Milan, Milan, Italy; Medical Physics Department, Veneto Institute of Oncology IOV-IRCCS, Padova, Italy
| | | | - Martina Camilla Daniotti
- Medical Physics Department, Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy; Department of Physics, University of Milan, Milan, Italy
| | - Sofia Bianchi
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy; Radiation Oncology Department, Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy
| | - Bianca Bordigoni
- Medical Physics Department, Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy
| | - Stefano Carminati
- Medical Physics Department, Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy; Department of Physics, University of Milan, Milan, Italy
| | - Valeria Faccenda
- Medical Physics Department, Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy
| | - Denis Panizza
- Medical Physics Department, Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy; School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
| | - Gianluca Montanari
- Medical Physics Department, Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy
| | - Stefano Arcangeli
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy; Radiation Oncology Department, Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy.
| | - Elena De Ponti
- Medical Physics Department, Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy; School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
| |
Collapse
|
2
|
Caricato P, Trivellato S, Pellegrini R, Montanari G, Daniotti MC, Bordigoni B, Faccenda V, Panizza D, Meregalli S, Bonetto E, Voet P, Arcangeli S, De Ponti E. Updating approach for lexicographic optimization-based planning to improve cervical cancer plan quality. Discov Oncol 2023; 14:180. [PMID: 37775613 PMCID: PMC10541351 DOI: 10.1007/s12672-023-00800-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2023] [Accepted: 09/25/2023] [Indexed: 10/01/2023] Open
Abstract
BACKGROUND To investigate the capability of a not-yet commercially available fully automated lexicographic optimization (LO) planning algorithm, called mCycle (Elekta AB, Stockholm, Sweden), to further improve the plan quality of an already-validated Wish List (WL) pushing on the organs-at-risk (OAR) sparing without compromising target coverage and plan delivery accuracy. MATERIAL AND METHODS Twenty-four mono-institutional consecutive cervical cancer Volumetric-Modulated Arc Therapy (VMAT) plans delivered between November 2019 and April 2022 (50 Gy/25 fractions) have been retrospectively selected. In mCycle the LO planning algorithm was combined with the a-priori multi-criterial optimization (MCO). Two versions of WL have been defined to reproduce manual plans (WL01), and to improve the OAR sparing without affecting minimum target coverage and plan delivery accuracy (WL02). Robust WLs have been tuned using a subset of 4 randomly selected patients. The remaining plans have been automatically re-planned by using the designed WLs. Manual plans (MP) and mCycle plans (mCP01 and mCP02) were compared in terms of dose distributions, complexity, delivery accuracy, and clinical acceptability. Two senior physicians independently performed a blind clinical evaluation, ranking the three competing plans. Furthermore, a previous defined global quality index has been used to gather into a single score the plan quality evaluation. RESULTS The WL tweaking requests 5 and 3 working days for the WL01 and the WL02, respectively. The re-planning took in both cases 3 working days. mCP01 best performed in terms of target coverage (PTV V95% (%): MP 98.0 [95.6-99.3], mCP01 99.2 [89.7-99.9], mCP02 96.9 [89.4-99.5]), while mCP02 showed a large OAR sparing improvement, especially in the rectum parameters (e.g., Rectum D50% (Gy): MP 41.7 [30.2-47.0], mCP01 40.3 [31.4-45.8], mCP02 32.6 [26.9-42.6]). An increase in plan complexity has been registered in mCPs without affecting plan delivery accuracy. In the blind comparisons, all automated plans were considered clinically acceptable, and mCPs were preferred over MP in 90% of cases. Globally, automated plans registered a plan quality score at least comparable to MP. CONCLUSIONS This study showed the flexibility of the Lexicographic approach in creating more demanding Wish Lists able to potentially minimize toxicities in RT plans.
Collapse
Affiliation(s)
- Paolo Caricato
- Medical Physics Department, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy.
- Department of Physics, University of Milan, Milan, Italy.
| | - Sara Trivellato
- Medical Physics Department, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
| | | | - Gianluca Montanari
- Medical Physics Department, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
| | - Martina Camilla Daniotti
- Medical Physics Department, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
- Department of Physics, University of Milan, Milan, Italy
| | - Bianca Bordigoni
- Medical Physics Department, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
- Department of Physics, University of Milano Bicocca, Milan, Italy
| | - Valeria Faccenda
- Medical Physics Department, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
- Department of Physics, University of Milan, Milan, Italy
| | - Denis Panizza
- Medical Physics Department, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
| | - Sofia Meregalli
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
- Department of Radiation Oncology, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
| | - Elisa Bonetto
- Department of Radiation Oncology, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
| | - Peter Voet
- Research Clinical Liaison, Elekta AB, Stockholm, Sweden
| | - Stefano Arcangeli
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
- Department of Radiation Oncology, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
| | - Elena De Ponti
- Medical Physics Department, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
| |
Collapse
|
3
|
Trivellato S, Caricato P, Pellegrini R, Montanari G, Daniotti MC, Bordigoni B, Faccenda V, Panizza D, Meregalli S, Bonetto E, Arcangeli S, De Ponti E. Comprehensive dosimetric and clinical evaluation of lexicographic optimization-based planning for cervical cancer. Front Oncol 2022; 12:1041839. [PMID: 36465394 PMCID: PMC9709287 DOI: 10.3389/fonc.2022.1041839] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Accepted: 10/25/2022] [Indexed: 11/01/2023] Open
Abstract
AIM In this study, a not yet commercially available fully-automated lexicographic optimization (LO) planning algorithm, called mCycle (Elekta AB, Stockholm, Sweden), was validated for cervical cancer. MATERIAL AND METHODS Twenty-four mono-institutional consecutive treatment plans (50 Gy/25 fx) delivered between November 2019 and April 2022 were retrospectively selected. The automatic re-planning was performed by mCycle, implemented in the Monaco TPS research version (v5.59.13), in which the LO and Multicriterial Optimization (MCO) are coupled with Monte Carlo calculation. mCycle optimization follows an a priori assigned priority list, the so-called Wish List (WL), representing a dialogue between the radiation oncologist and the planner, setting hard constraints and following objectives. The WL was tuned on a patient subset according to the institution's clinical protocol to obtain an optimal plan in a single optimization. This robust WL was then used to automatically re-plan the remaining patients. Manual plans (MP) and mCycle plans (mCP) were compared in terms of dose distributions, complexity (modulation complexity score, MCS), and delivery accuracy (perpendicular diode matrices, gamma analysis-passing ratio, PR). Their clinical acceptability was assessed through the blind choice of two radiation oncologists. Finally, a global quality score index (SI) was defined to gather into a single number the plan evaluation process. RESULTS The WL tuning requested four patients. The 20 automated re-planning tasks took three working days. The median optimization and calculation time can be estimated at 4 h and just over 1 h per MP and mCP, respectively. The dose comparison showed a comparable organ-at-risk spare. The planning target volume coverage increased (V95%: MP 98.0% [95.6-99.3]; mCP 99.2%[89.7-99.9], p >0.05). A significant increase has been registered in MCS (MP 0.29 [0.24-0.34]; mCP 0.26 [0.23-0.30], p <0.05) without affecting delivery accuracy (PR (3%/3mm): MP 97.0% [92.7-99.2]; mCP 97.1% [95.0-98.6], p >0.05). In the blind choice, all mCP results were clinically acceptable and chosen over MP in more than 75% of cases. The median SI score was 0.69 [0.41-0.84] and 0.73 [0.51-0.82] for MP and mCP, respectively (p >0.05). CONCLUSIONS mCycle plans were comparable to clinical manual plans, more complex but accurately deliverable and registering a similar SI. Automated plans outperformed manual plans in blinded clinical choice.
Collapse
Affiliation(s)
- Sara Trivellato
- Medical Physics Department, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
| | - Paolo Caricato
- Medical Physics Department, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
- Department of Physics, University of Milan, Milan, Italy
| | | | - Gianluca Montanari
- Medical Physics Department, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
| | - Martina Camilla Daniotti
- Medical Physics Department, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
- Department of Physics, University of Milan, Milan, Italy
| | - Bianca Bordigoni
- Medical Physics Department, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
- Department of Physics, University of Milan Bicocca, Milan, Italy
| | - Valeria Faccenda
- Medical Physics Department, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
- Department of Physics, University of Milan, Milan, Italy
| | - Denis Panizza
- Medical Physics Department, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
| | - Sofia Meregalli
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
- Department of Radiation Oncology, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
| | - Elisa Bonetto
- Department of Radiation Oncology, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
| | - Stefano Arcangeli
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
- Department of Radiation Oncology, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
| | - Elena De Ponti
- Medical Physics Department, Azienda Socio Sanitaria Territoriale (ASST) Monza, Monza, Italy
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
| |
Collapse
|
4
|
Cao R, Si L, Li X, Guang Y, Wang C, Tian Y, Pei X, Zhang X. A conjugate gradient-assisted multi-objective evolutionary algorithm for fluence map optimization in radiotherapy treatment. COMPLEX INTELL SYST 2022. [DOI: 10.1007/s40747-022-00697-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
AbstractIntensity-modulated radiotherapy (IMRT) is one of the most applied techniques for cancer radiotherapy treatment. The fluence map optimization is an essential part of IMRT plan designing, which has a significant impact on the radiotherapy treatment effect. In fact, the treatment planing of IMRT is an inverse multi-objective optimization problem. Existing approaches of solving the fluence map optimization problem (FMOP) obtain a satisfied treatment plan via trying different coupling weights, the optimization process needs to be conducted many times and the coupling weight setting is completely based on the experience of a radiation physicist. For fast obtaining diverse high-quality radiotherapy plans, this paper formulates the FMOP into a three-objective optimization problem, and proposes a conjugate gradient-assisted multi-objective evolutionary algorithm (CG-MOEA) to solve it. The proposed algorithm does not need to set the coupling weights and can produce the diverse radiotherapy plans within a single run. Moreover, the convergence speed is further accelerated by an adaptive local search strategy based on the conjugate-gradient method. Compared with five state-of-the-art multi-objective evolutionary algorithms (MOEAs), the proposed CG-MOEA can obtain the best hypervolume (HV) values and dose–volume histogram (DVH) performance on five clinical cases in cancer radiotherapy. Moreover, the proposed algorithm not only obtains the more optimal solution than traditional method used to solve the FMOP, but also can find diverse Pareto solution set which can be provided to radiation physicist to select the best treatment plan. The proposed algorithm outperforms dose-volume histogram state-of-the-art multi-objective evolutionary algorithms and traditional method for FMOP on five clinical cases in cancer radiotherapy.
Collapse
|
5
|
Huang C, Yang Y, Panjwani N, Boyd S, Xing L. Pareto Optimal Projection Search (POPS): Automated Radiation Therapy Treatment Planning by Direct Search of the Pareto Surface. IEEE Trans Biomed Eng 2021; 68:2907-2917. [PMID: 33523802 PMCID: PMC8526351 DOI: 10.1109/tbme.2021.3055822] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
OBJECTIVE Radiation therapy treatment planning is a time-consuming, iterative process with potentially high inter-planner variability. Fully automated treatment planning processes could reduce a planner's active treatment planning time and remove inter-planner variability, with the potential to tremendously improve patient turnover and quality of care. In developing fully automated algorithms for treatment planning, we have two main objectives: to produce plans that are 1) Pareto optimal and 2) clinically acceptable. Here, we propose the Pareto optimal projection search (POPS) algorithm, which provides a general framework for directly searching the Pareto front. METHODS Our POPS algorithm is a novel automated planning method that combines two main search processes: 1) gradient-free search in the decision variable space and 2) projection of decision variables to the Pareto front using the bisection method. We demonstrate the performance of POPS by comparing with clinical treatment plans. As one possible quantitative measure of treatment plan quality, we construct a clinical acceptability scoring function (SF) modified from the previously developed general evaluation metric (GEM). RESULTS On a dataset of 21 prostate cases collected as part of clinical workflow, our proposed POPS algorithm produces Pareto optimal plans that are clinically acceptable in regards to dose conformity, dose homogeneity, and sparing of organs-at-risk. CONCLUSION Our proposed POPS algorithm provides a general framework for fully automated treatment planning that achieves clinically acceptable dosimetric quality without requiring active planning from human planners. SIGNIFICANCE Our fully automated POPS algorithm addresses many key limitations of other automated planning approaches, and we anticipate that it will substantially improve treatment planning workflow.
Collapse
|
6
|
Hüyük A, Tekin C. Multi-objective multi-armed bandit with lexicographically ordered and satisficing objectives. Mach Learn 2021. [DOI: 10.1007/s10994-021-05956-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
7
|
Taasti VT, Hong L, Deasy JO, Zarepisheh M. Automated proton treatment planning with robust optimization using constrained hierarchical optimization. Med Phys 2020; 47:2779-2790. [PMID: 32196679 DOI: 10.1002/mp.14148] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 03/02/2020] [Accepted: 03/11/2020] [Indexed: 11/06/2022] Open
Abstract
PURPOSE We present a method for fully automated generation of high quality robust proton treatment plans using hierarchical optimization. To fill the gap between the two common extreme robust optimization approaches, that is, stochastic and worst-case, a robust optimization approach based on the p-norm function is used whereby a single parameter, p , can be used to control the level of robustness in an intuitive way. METHODS A fully automated approach to treatment planning using Expedited Constrained Hierarchical Optimization (ECHO) is implemented in our clinic for photon treatments. ECHO strictly enforces critical (inviolable) clinical criteria as hard constraints and improves the desirable clinical criteria sequentially, as much as is feasible. We extend our in-house developed ECHO codes for proton therapy and integrate it with a new approach for robust optimization. Multiple scenarios accounting for both setup and range uncertainties are included (13scenarios), and the maximum/mean/dose-volume constraints on organs-at-risk (OARs) and target are fulfilled in all scenarios. We combine the objective functions of the individual scenarios using the p-norm function. The p-norm with a parameter p = 1 or p = ∞ result in the stochastic or the worst-case approach, respectively; an intermediate robustness level is obtained by employing p -values in-between. While the worst-case approach only focuses on the worst-case scenario(s), the p-norm approach with a large p value ( p ≈ 20 ) resembles the worst-case approach without completely neglecting other scenarios. The proposed approach is evaluated on three head-and-neck (HN) patients and one water phantom with different parameters, p ∈ 1 , 2 , 5 , 10 , 20 . The results are compared against the stochastic approach (p-norm approach with p = 1 ) and the worst-case approach, as well as the nonrobust approach (optimized solely on the nominal scenario). RESULTS The proposed algorithm successfully generates automated robust proton plans on all cases. As opposed to the nonrobust plans, the robust plans have narrower dose volume histogram (DVH) bands across all 13 scenarios, and meet all hard constraints (i.e., maximum/mean/dose-volume constraints) on OARs and the target for all scenarios. The spread in the objective function values is largest for the stochastic approach ( p = 1 ) and decreases with increasing p toward the worst-case approach. Compared to the worst-case approach, the p-norm approach results in DVH bands for clinical target volume (CTV) which are closer to the prescription dose at a negligible cost in the DVH for the worst scenario, thereby improving the overall plan quality. On average, going from the worst-case approach to the p-norm approach with p = 20 , the median objective function value across all the scenarios is improved by 15% while the objective function value for the worst scenario is only degraded by 3%. CONCLUSION An automated treatment planning approach for proton therapy is developed, including robustness, dose-volume constraints, and the ability to control the robustness level using the p-norm parameter p , to fit the priorities deemed most important.
Collapse
Affiliation(s)
- Vicki T Taasti
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Linda Hong
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Joseph O Deasy
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Masoud Zarepisheh
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| |
Collapse
|
8
|
Hong L, Zhou Y, Yang J, Mechalakos JG, Hunt MA, Mageras GS, Yang J, Yamada J, Deasy JO, Zarepisheh M. Clinical Experience of Automated SBRT Paraspinal and Other Metastatic Tumor Planning With Constrained Hierarchical Optimization. Adv Radiat Oncol 2019; 5:1042-1050. [PMID: 33083666 PMCID: PMC7557131 DOI: 10.1016/j.adro.2019.11.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 11/12/2019] [Accepted: 11/26/2019] [Indexed: 11/18/2022] Open
Abstract
Purpose We report on the clinical performance of a fully automated approach to treatment planning based on a Pareto optimal, constrained hierarchical optimization algorithm, named Expedited Constrained Hierarchical Optimization (ECHO). Methods and materials From April 2017 to October 2018, ECHO produced 640 treated plans for 523 patients who underwent stereotactic body radiation therapy (RT) for paraspinal and other metastatic tumors. A total of 182 plans were for 24 Gy in a single fraction, 387 plans were for 27 Gy in 3 fractions, and the remainder were for other prescriptions or fractionations. Of the plans, 84.5% were for paraspinal tumors, with 69, 302, and 170 in the cervical, thoracic, and lumbosacral spine, respectively. For each case, after contouring, a template plan using 9 intensity modulated RT fields based on disease site and tumor location was sent to ECHO through an application program interface plug-in from the treatment planning system. ECHO returned a plan that satisfied all critical structure hard constraints with optimal target volume coverage and the lowest achievable normal tissue doses. Upon ECHO completion, the planner received an e-mail indicating the plan was ready for review. The plan was accepted if all clinical criteria were met. Otherwise, a limited number of parameters could be adjusted for another ECHO run. Results The median planning target volume size was 84.3 cm3 (range, 6.9-633.2). The median time to produce 1 ECHO plan was 63.5 minutes (range, 11-340 minutes) and was largely dependent on the field sizes. Of the cases, 79.7% required 1 run to produce a clinically accepted plan, 13.3% required 1 additional run with minimal parameter adjustments, and 7.0% required ≥2 additional runs with significant parameter modifications. All plans met or bettered the institutional clinical criteria. Conclusions We successfully implemented automated stereotactic body RT paraspinal and other metastatic tumors planning. ECHO produced high-quality plans, improved planning efficiency and robustness, and enabled expedited treatment planning at our clinic.
Collapse
Affiliation(s)
- Linda Hong
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Ying Zhou
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Jie Yang
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - James G Mechalakos
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Margie A Hunt
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Gig S Mageras
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Jonathan Yang
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Josh Yamada
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Joseph O Deasy
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Masoud Zarepisheh
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| |
Collapse
|
9
|
Verbakel WF, Doornaert PA, Raaijmakers CP, Bos LJ, Essers M, van de Kamer JB, Dahele M, Terhaard CH, Kaanders JH. Targeted Intervention to Improve the Quality of Head and Neck Radiation Therapy Treatment Planning in the Netherlands: Short and Long-Term Impact. Int J Radiat Oncol Biol Phys 2019; 105:514-524. [DOI: 10.1016/j.ijrobp.2019.07.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Revised: 06/20/2019] [Accepted: 07/04/2019] [Indexed: 12/18/2022]
|
10
|
|
11
|
Cozzi L. Advanced treatment planning strategies to enhance quality and efficiency of radiotherapy. Phys Imaging Radiat Oncol 2019; 11:69-70. [PMID: 33458281 PMCID: PMC7807646 DOI: 10.1016/j.phro.2019.09.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Affiliation(s)
- Luca Cozzi
- Radiotherapy and Radiosurgery, Humanitas Clinical and Research Center, Rozzano (Milan), Italy
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele (Milan), Italy
| |
Collapse
|
12
|
Zarepisheh M, Hong L, Zhou Y, Oh JH, Mechalakos JG, Hunt MA, Mageras GS, Deasy JO. Automated intensity modulated treatment planning: The expedited constrained hierarchical optimization (ECHO) system. Med Phys 2019; 46:2944-2954. [PMID: 31055858 DOI: 10.1002/mp.13572] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Revised: 04/25/2019] [Accepted: 04/25/2019] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To develop and implement a fully automated approach to intensity modulated radiation therapy (IMRT) treatment planning. METHOD The optimization algorithm is developed based on a hierarchical constrained optimization technique and is referred internally at our institution as expedited constrained hierarchical optimization (ECHO). Beamlet contributions to regions-of-interest are precomputed and captured in the influence matrix. Planning goals are of two classes: hard constraints that are strictly enforced from the first step (e.g., maximum dose to spinal cord), and desirable goals that are sequentially introduced in three constrained optimization problems (better planning target volume (PTV) coverage, lower organ at risk (OAR) doses, and smoother fluence map). After solving the optimization problems using external commercial optimization engines, the optimal fluence map is imported into an FDA-approved treatment planning system (TPS) for leaf sequencing and accurate full dose calculation. The dose-discrepancy between the optimization and TPS dose calculation is then calculated and incorporated into optimization by a novel dose correction loop technique using Lagrange multipliers. The correction loop incorporates the leaf sequencing and scattering effects into optimization to improve the plan quality and reduce the calculation time. The resultant optimal fluence map is again imported into TPS for leaf sequencing and final dose calculation for plan evaluation and delivery. The workflow is automated using application program interface (API) scripting, requiring user interaction solely to prepare the contours and beam arrangement prior to launching the ECHO plug-in from the TPS. For each site, parameters and objective functions are chosen to represent clinical priorities. The first site chosen for clinical implementation was metastatic paraspinal lesions treated with stereotactic body radiotherapy (SBRT). As a first step, 75 ECHO paraspinal plans were generated retrospectively and compared with clinically treated plans generated by planners using VMAT (volumetric modulated arc therapy) with 4 to 6 partial arcs. Subsequently, clinical deployment began in April, 2017. RESULTS In retrospective study, ECHO plans were found to be dosimetrically superior with respect to tumor coverage, plan conformity, and OAR sparing. For example, the average PTV D95%, cord and esophagus max doses, and Paddick Conformity Index were improved, respectively, by 1%, 6%, 14%, and 15%, at a negligible 3% cost of the average skin D10cc dose. CONCLUSION Hierarchical constrained optimization is a powerful and flexible tool for automated IMRT treatment planning. The dosimetric correction step accurately accounts for detailed dosimetric multileaf collimator and scattering effects. The system produces high-quality, Pareto optimal plans and avoids the time-consuming trial-and-error planning process.
Collapse
Affiliation(s)
- Masoud Zarepisheh
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Linda Hong
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Ying Zhou
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Jung Hun Oh
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - James G Mechalakos
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Margie A Hunt
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Gig S Mageras
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Joseph O Deasy
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| |
Collapse
|
13
|
Wedenberg M, Beltran C, Mairani A, Alber M. Advanced Treatment Planning. Med Phys 2018; 45:e1011-e1023. [PMID: 30421811 DOI: 10.1002/mp.12943] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2017] [Revised: 03/22/2018] [Accepted: 04/22/2018] [Indexed: 12/15/2022] Open
Abstract
Treatment planning for protons and heavier ions is adapting technologies originally developed for photon dose optimization, but also has to meet its particular challenges. Since the quality of the applied dose is more sensitive to geometric uncertainties, treatment plan robust optimization has a much more prominent role in particle therapy. This has led to specific planning tools, approaches, and research into new formulations of the robust optimization problems. Tools for solution space navigation and automatic planning are also being adapted to particle therapy. These challenges become even greater when detailed models of relative biological effectiveness (RBE) are included into dose optimization, as is required for heavier ions.
Collapse
Affiliation(s)
| | - Chris Beltran
- Division of Medical Physics, Department of Radiation Oncology, Mayo Clinic, Rochester, MN, USA
| | - Andrea Mairani
- Heidelberg Ion Therapy Center (HIT), Heidelberg University Hospital, Heidelberg, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany.,The National Centre for Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Markus Alber
- The National Centre for Oncological Hadrontherapy (CNAO), Pavia, Italy.,Section for Medical Physics, Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| |
Collapse
|
14
|
Mai Y, Kong F, Yang Y, Zhou L, Li Y, Song T. Voxel-based automatic multi-criteria optimization for intensity modulated radiation therapy. Radiat Oncol 2018; 13:241. [PMID: 30518381 PMCID: PMC6280392 DOI: 10.1186/s13014-018-1179-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Accepted: 11/09/2018] [Indexed: 11/10/2022] Open
Abstract
Background Automatic multi-criteria optimization is necessary for intensity modulated radiation therapy (IMRT) because of low planning efficiency and large plan quality uncertainty in current clinical practice. Most studies focused on imitating dosimetrists’ planning procedures to automate this process and ignored the fact that organ-based objective functions typically used in commercial treatment planning systems (such as dose-volume function) usually lead to sub-optimal plans. To guarantee the optimum results and to automate this process, we incorporate an improved automation strategy and a voxel-based optimization algorithm to generate a novel automatic multi-criteria optimization framework. We then evaluate it in clinical cases. Methods This novel automatic multi-criteria optimization framework incorporates a ranked priority-list based automatic constraints adjustment strategy and an in-house developed voxel-based optimization algorithm. Constraints are sequentially adjusted following a pre-defined priority list. Afterward, a voxel-based fluence map optimization (FMO) with an orientation to the newly updated constraints is launched to find a Pareto optimal solution. Loops of constraints adjustment are repeated until each of them could not be relaxed or tightened. The feasibility of the framework is evaluated with 10 automatic generated gynecology (GYN) cancer IMRT cases by comparing the dosimetric performance with the original. Results Plan quality improvement is observed for our automatic multi-criteria optimization method. Comparable DVHs are found for the planning target volume (PTV), but with better organs-at-risk (OAR) dose sparing. Among 13 evaluated dosimetric endpoints, 5 of them show significant improvements in automatically generated plans compared with the original plans. Investigation of improvement tendency during optimization exhibits gradual change as the optimization stage proceeds. An initial voxel-based optimization stage and in-low-priority dosimetric criteria tighten can significantly contribute to the optimization procedure. Conclusions We have successfully developed an automatic multi-criteria optimization framework that can dramatically reduce the current trial-and-error patterned planning workload while affording an efficient method to assure high plan quality consistency. This optimization framework is expected to greatly facilitate precise radiation therapy because of its advantages of planning efficiency and plan quality improvement.
Collapse
Affiliation(s)
- Yanhua Mai
- Department of Biomedical Engineering, Southern Medical University, Guangzhou, 510515, Guangdong, China
| | - Fantu Kong
- Department of Biomedical Engineering, Southern Medical University, Guangzhou, 510515, Guangdong, China
| | - Yiwei Yang
- Department of Radiation Oncology, Zhejiang Cancer Hospital, Zhejiang, 310022, Hangzhou, China
| | - Linghong Zhou
- Department of Biomedical Engineering, Southern Medical University, Guangzhou, 510515, Guangdong, China.
| | - Yongbao Li
- Department of Radiation Oncology, Sun Yat-Sen University Cancer Center,State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, 510060, China.
| | - Ting Song
- Department of Biomedical Engineering, Southern Medical University, Guangzhou, 510515, Guangdong, China.
| |
Collapse
|
15
|
Hussein M, Heijmen BJM, Verellen D, Nisbet A. Automation in intensity modulated radiotherapy treatment planning-a review of recent innovations. Br J Radiol 2018; 91:20180270. [PMID: 30074813 DOI: 10.1259/bjr.20180270] [Citation(s) in RCA: 142] [Impact Index Per Article: 23.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
Radiotherapy treatment planning of complex radiotherapy techniques, such as intensity modulated radiotherapy and volumetric modulated arc therapy, is a resource-intensive process requiring a high level of treatment planner intervention to ensure high plan quality. This can lead to variability in the quality of treatment plans and the efficiency in which plans are produced, depending on the skills and experience of the operator and available planning time. Within the last few years, there has been significant progress in the research and development of intensity modulated radiotherapy treatment planning approaches with automation support, with most commercial manufacturers now offering some form of solution. There is a rapidly growing number of research articles published in the scientific literature on the topic. This paper critically reviews the body of publications up to April 2018. The review describes the different types of automation algorithms, including the advantages and current limitations. Also included is a discussion on the potential issues with routine clinical implementation of such software, and highlights areas for future research.
Collapse
Affiliation(s)
- Mohammad Hussein
- 1 Metrology for Medical Physics Centre, National Physical Laboratory , Teddington , UK
| | - Ben J M Heijmen
- 2 Division of Medical Physics, Erasmus MC Cancer Institute , Rotterdam , The Netherlands
| | - Dirk Verellen
- 3 Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel (VUB) , Brussels , Belgium.,4 Radiotherapy Department, Iridium Kankernetwerk , Antwerp , Belgium
| | - Andrew Nisbet
- 5 Department of Medical Physics, Royal Surrey County Hospital NHS Foundation Trust , Guildford , UK.,6 Department of Physics, University of Surrey , Guildford , UK
| |
Collapse
|
16
|
Lin YH, Hong LX, Hunt MA, Berry SL. Use of a constrained hierarchical optimization dataset enhances knowledge-based planning as a quality assurance tool for prostate bed irradiation. Med Phys 2018; 45:4364-4369. [PMID: 30168160 DOI: 10.1002/mp.13163] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2017] [Revised: 05/15/2018] [Accepted: 08/21/2018] [Indexed: 11/10/2022] Open
Abstract
PURPOSE To investigate whether building a knowledge-based planning (KBP) model with prostate bed plans constructed from constrained hierarchical optimization (CHO) would result in more efficient model construction with more consistent output than a model built using plans from a traditional, trial-and-error-based optimization (TEO) technique. METHODS Three KBP models were constructed from plans from subsets of 58 post-prostatectomy patients treated with intensity-modulated radiation therapy. TEO54 was built from 54 TEO plans, selected to represent typical clinical variations in target and organ-at-risk sizes and shapes. CHO30 and TEO30 were built from the same 30 patients populated with CHO and TEO plans, respectively. The three models were each applied to a new set of 18 patient scans and dose-volume histogram estimates (DVHEs) were generated for rectal and bladder walls and compared for each patient. RESULTS CHO30 resulted in a significantly tighter range in DVHEs (P < 0.01) for both the rectal and bladder walls compared with either of the TEO models, indicating less uncertainty in the dose estimation. Plans resulting from KBP optimization using each model were very similar. CONCLUSION Populating a KBP model with CHO data resulted in a high quality model. Since CHO plans can be generated automatically offline in a process that necessitates little to no user interaction, a CHO-KBP model can quickly adapt to changes in plan evaluation criteria or planning techniques without the need to wait to accrue sufficient numbers of clinical TEO plans. This may facilitate the use of KBP approaches for initial or ongoing quality assurance procedures and plan quality audits.
Collapse
Affiliation(s)
- Yen Hwa Lin
- Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3, Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Linda X Hong
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Margie A Hunt
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Sean L Berry
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| |
Collapse
|
17
|
麦 燕, 孔 繁, 杨 一, 李 永, 宋 婷, 周 凌. [Constraint priority list-based multi-objective optimization for intensity-modulated radiation therapy]. NAN FANG YI KE DA XUE XUE BAO = JOURNAL OF SOUTHERN MEDICAL UNIVERSITY 2018; 38:691-697. [PMID: 29997091 PMCID: PMC6765717 DOI: 10.3969/j.issn.1673-4254.2018.06.08] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 02/04/2018] [Indexed: 06/08/2023]
Abstract
In intensity-modulated radiation therapy (IMRT), it is time-consuming to repeatedly adjust the objectives manually to obtain the best tradeoff between the prescribed dose of the planning target volume and sparing the organs-at-risk. Here we propose a new method to realize automatic multi-objective IMRT optimization, which quantifies the clinical preferences into the constraint priority list and adjusts the dose constraints based on the list to obtain the optimal solutions under the dose constraints. This method contains automatic adjustment mechanism of the dose constraint and automatic voxel weighting factor-based FMO model. Every time the dose constraint is adjusted, the voxel weighting factor-based FMO model is launched to find a global optimal solution that satisfied the current constraints. We tested the feasibility and effectiveness of this method in 6 cases of cervical cancer with IMRT by comparing the original plan and the automatic optimization plan generated by this method. The results showed that with the same PTV coverage and uniformity, the automatic optimization plan had a better a dose sparing of the organs-at-risk and a better plan quality than the original plan, and resulted in obvious reductions of the average V45 of the rectum from (41.99∓13.31)% to (32.55∓22.27)% and of the bladder from (44.37∓4.08)% to (28.99∓15.25)%.
Collapse
Affiliation(s)
- 燕华 麦
- 南方医科大学生物医学工程学院,广东 广州 510515Department of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China
| | - 繁图 孔
- 南方医科大学生物医学工程学院,广东 广州 510515Department of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China
| | - 一威 杨
- 浙江省肿瘤医院放疗科,浙江 杭州 310022Department of Radiation Therapy, Zhejiang Provincial Cancer Hospital, Hangzhou 310022, China
| | - 永宝 李
- 中山大学肿瘤防治中心,广东 广州 510060Sun Yat-sen University Cancer Center, Guangzhou 510060, China
| | - 婷 宋
- 南方医科大学生物医学工程学院,广东 广州 510515Department of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China
| | - 凌宏 周
- 南方医科大学生物医学工程学院,广东 广州 510515Department of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China
| |
Collapse
|
18
|
Wang J, Chen Z, Li W, Qian W, Wang X, Hu W. A new strategy for volumetric-modulated arc therapy planning using AutoPlanning based multicriteria optimization for nasopharyngeal carcinoma. Radiat Oncol 2018; 13:94. [PMID: 29769101 PMCID: PMC5956620 DOI: 10.1186/s13014-018-1042-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Accepted: 05/01/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND A new strategy for making the appropriate choice of the representative optimization parameters in planning processes and accurate selection criteria during Pareto surface navigation for general multicriteria optimization (MCO) was recommended in the study. The purpose was to combine both benefits of AutoPlanning optimization and MCO (APMCO) for achieving an individual volumetric-modulated arc therapy (VMAT) plan according to the clinically achieved patient-specific tradeoff among conflicting priorities. The preclinical investigation of this optimization approach for nasopharyngeal carcinoma (NPC) radiotherapy was performed and compared to general MCO VMAT. METHODS A total of 60 NPC patients with various stages were enrolled in this study. General MCO and APMCO plans were generated for each patient on the treatment planning system. The differences between two planning schemes were evaluated and compared. RESULTS All plans were capable of achieving the prescription requirement. The planning target volume coverage and conformation number were remarkably similar between general MCO and APMCO plans. There were no significant differences in most of organs at risk (OARs) sparing. However, in APMCO plans, relatively remarkable decreases were observed in the mean dose (Dmean) to the glottic larynx and pharyngeal constrictor muscles. The reductions of average Dmean to the two OARs were 10.5% (p < 0.0001) and 8.4% (p < 0.0001), respectively. APMCO technique was found to increase the planning time for an average of approximately 5 h and did not lead to a significant increase of monitor units compared to general MCO. CONCLUSIONS The potential of the APMCO strategy is best realized with a clinical implementation that exploits individual generation of Pareto surface representations without manual interaction. It also assists physicians to ensure navigation in a more efficient and straightforward manner.
Collapse
Affiliation(s)
- Juanqi Wang
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Zhi Chen
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Weiwei Li
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Wei Qian
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Xiaosheng Wang
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Weigang Hu
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, China. .,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China.
| |
Collapse
|
19
|
Lin KM, Ehrgott M. Multiobjective navigation of external radiotherapy plans based on clinical criteria. JOURNAL OF MULTI-CRITERIA DECISION ANALYSIS 2018. [DOI: 10.1002/mcda.1628] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
20
|
van Haveren R, Ogryczak W, Verduijn GM, Keijzer M, Heijmen BJM, Breedveld S. Fast and fuzzy multi-objective radiotherapy treatment plan generation for head and neck cancer patients with the lexicographic reference point method (LRPM). Phys Med Biol 2017; 62:4318-4332. [PMID: 28475495 DOI: 10.1088/1361-6560/62/11/4318] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Previously, we have proposed Erasmus-iCycle, an algorithm for fully automated IMRT plan generation based on prioritised (lexicographic) multi-objective optimisation with the 2-phase ϵ-constraint (2pϵc) method. For each patient, the output of Erasmus-iCycle is a clinically favourable, Pareto optimal plan. The 2pϵc method uses a list of objective functions that are consecutively optimised, following a strict, user-defined prioritisation. The novel lexicographic reference point method (LRPM) is capable of solving multi-objective problems in a single optimisation, using a fuzzy prioritisation of the objectives. Trade-offs are made globally, aiming for large favourable gains for lower prioritised objectives at the cost of only slight degradations for higher prioritised objectives, or vice versa. In this study, the LRPM is validated for 15 head and neck cancer patients receiving bilateral neck irradiation. The generated plans using the LRPM are compared with the plans resulting from the 2pϵc method. Both methods were capable of automatically generating clinically relevant treatment plans for all patients. For some patients, the LRPM allowed large favourable gains in some treatment plan objectives at the cost of only small degradations for the others. Moreover, because of the applied single optimisation instead of multiple optimisations, the LRPM reduced the average computation time from 209.2 to 9.5 min, a speed-up factor of 22 relative to the 2pϵc method.
Collapse
Affiliation(s)
- Rens van Haveren
- Department of Radiation Oncology, Erasmus MC-Cancer Institute, PO Box 2040, 3000 CA Rotterdam, The Netherlands
| | | | | | | | | | | |
Collapse
|
21
|
Particle swarm optimizer for weighting factor selection in intensity-modulated radiation therapy optimization algorithms. Phys Med 2017; 33:136-145. [DOI: 10.1016/j.ejmp.2016.12.021] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2016] [Revised: 12/19/2016] [Accepted: 12/31/2016] [Indexed: 12/25/2022] Open
|
22
|
Tol JP, Dahele M, Delaney AR, Doornaert P, Slotman BJ, Verbakel WFAR. Detailed evaluation of an automated approach to interactive optimization for volumetric modulated arc therapy plans. Med Phys 2016; 43:1818. [PMID: 27036579 DOI: 10.1118/1.4944063] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
PURPOSE Interactive optimization during treatment planning requires intermittent adjustment of organ-at-risk (OAR) objectives relative to the dose-volume histogram line. This is a labor-intensive process and the resulting plans are prone to variations in quality. The authors' in-house developed approach to automated interactive optimization (AIO) automatically moves the mouse cursor to adjust the position of on-screen optimization objectives. This allows for the use of more objectives per OAR and results in a more frequent and consistent adjustment of these objectives during optimization. The authors report a detailed evaluation of AIO performance in support of its implementation for routine head and neck cancer (HNC) planning and an evaluation for locally advanced lung cancer (LC) planning which requires a different optimization strategy. METHODS Volumetric modulated arc therapy AIO plans (APs) were created for 70 HNC patients with a simultaneously integrated boost and 20 LC patients and benchmarked against their respective manually interactively optimized plans (MPs). The same set of optimization objectives and priorities was used for all APs, although planning target volume (PTV) optimization priorities could be increased manually in a subsequent "continue previous optimization" calculation. HNC plans were benchmarked using mean dose to individual and composite OARs and elective/boost PTV (PTVE/PTVB) volumes receiving 95% and 107% of the prescription dose (V95% and V107%, respectively). A clinician performed blinded comparison of 20 APs and respective MPs. LC plans were compared using PTV V95%/V107%, contralateral lung (CL) volume receiving 5 Gy (V5Gy), total lung (TL)-PTV V5Gy/V20Gy, and esophagus and heart V40Gy/V60Gy/mean doses. RESULTS For HNC, statistically significant improvements in sparing of all OARs, except for the ipsilateral submandibular gland and trachea, were obtained in the APs compared to MPs. Average mean dose to oral cavity, composite salivary, and swallowing structures were 25.4/23.8, 24.2/23.2, and 29.5/25.5 Gy, respectively, for the MPs/APs. PTV heterogeneity was similar: in the APs, PTVB V95% was 0.2% higher while PTV B/PTV E V107% was 0.4%/1.0% lower. In 19 out of 20 HNC patients, the clinician preferred the AP, mainly because of better OAR sparing and PTV dose homogeneity. For LC, APs had a significantly lower CL V5Gy (6.1%), heart mean dose/V60Gy (0.9 Gy/1.2%) and esophagus mean dose/V60Gy (0.9 Gy/2.8%), a nonsignificantly higher TL V20Gy (1.4%), and a slight, but significantly higher dose deposition to the body. PTV dose coverage and homogeneity were similar in the APs and MPs. AIO was considered sufficiently robust for clinical use in LC. CONCLUSIONS HNC and LC APs were at least as good as, and often of improved quality over MPs. To date, AIO has been clinically implemented for HNC planning.
Collapse
Affiliation(s)
- Jim P Tol
- Department of Radiation Oncology, VU University Medical Center, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| | - Max Dahele
- Department of Radiation Oncology, VU University Medical Center, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| | - Alexander R Delaney
- Department of Radiation Oncology, VU University Medical Center, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| | - Patricia Doornaert
- Department of Radiation Oncology, VU University Medical Center, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| | - Ben J Slotman
- Department of Radiation Oncology, VU University Medical Center, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| | - Wilko F A R Verbakel
- Department of Radiation Oncology, VU University Medical Center, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| |
Collapse
|
23
|
Unkelbach J, Botas P, Giantsoudi D, Gorissen BL, Paganetti H. Reoptimization of Intensity Modulated Proton Therapy Plans Based on Linear Energy Transfer. Int J Radiat Oncol Biol Phys 2016; 96:1097-1106. [PMID: 27869082 PMCID: PMC5133459 DOI: 10.1016/j.ijrobp.2016.08.038] [Citation(s) in RCA: 135] [Impact Index Per Article: 16.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2016] [Revised: 08/19/2016] [Accepted: 08/25/2016] [Indexed: 01/20/2023]
Abstract
PURPOSE We describe a treatment plan optimization method for intensity modulated proton therapy (IMPT) that avoids high values of linear energy transfer (LET) in critical structures located within or near the target volume while limiting degradation of the best possible physical dose distribution. METHODS AND MATERIALS To allow fast optimization based on dose and LET, a GPU-based Monte Carlo code was extended to provide dose-averaged LET in addition to dose for all pencil beams. After optimizing an initial IMPT plan based on physical dose, a prioritized optimization scheme is used to modify the LET distribution while constraining the physical dose objectives to values close to the initial plan. The LET optimization step is performed based on objective functions evaluated for the product of LET and physical dose (LET×D). To first approximation, LET×D represents a measure of the additional biological dose that is caused by high LET. RESULTS The method is effective for treatments where serial critical structures with maximum dose constraints are located within or near the target. We report on 5 patients with intracranial tumors (high-grade meningiomas, base-of-skull chordomas, ependymomas) in whom the target volume overlaps with the brainstem and optic structures. In all cases, high LET×D in critical structures could be avoided while minimally compromising physical dose planning objectives. CONCLUSION LET-based reoptimization of IMPT plans represents a pragmatic approach to bridge the gap between purely physical dose-based and relative biological effectiveness (RBE)-based planning. The method makes IMPT treatments safer by mitigating a potentially increased risk of side effects resulting from elevated RBE of proton beams near the end of range.
Collapse
Affiliation(s)
- Jan Unkelbach
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts.
| | - Pablo Botas
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts; Faculty of Physics, Ruprecht-Karls-Universität Heidelberg, Heidelberg, Germany
| | - Drosoula Giantsoudi
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts
| | - Bram L Gorissen
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts
| | - Harald Paganetti
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts
| |
Collapse
|
24
|
Matuszak MM, Matrosic C, Jarema D, McShan DL, Stenmark MH, Owen D, Jolly S, Kong FMS, Ten Haken RK. Priority-driven plan optimization in locally advanced lung patients based on perfusion SPECT imaging. Adv Radiat Oncol 2016; 1:281-289. [PMID: 28740898 PMCID: PMC5514230 DOI: 10.1016/j.adro.2016.10.007] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2016] [Revised: 10/13/2016] [Accepted: 10/24/2016] [Indexed: 12/25/2022] Open
Abstract
Purpose Limits on mean lung dose (MLD) allow for individualization of radiation doses at safe levels for patients with lung tumors. However, MLD does not account for individual differences in the extent or spatial distribution of pulmonary dysfunction among patients, which leads to toxicity variability at the same MLD. We investigated dose rearrangement to minimize the radiation dose to the functional lung as assessed by perfusion single photon emission computed tomography (SPECT) and maximize the target coverage to maintain conventional normal tissue limits. Methods and materials Retrospective plans were optimized for 15 patients with locally advanced non-small cell lung cancer who were enrolled in a prospective imaging trial. A staged, priority-based optimization system was used. The baseline priorities were to meet physical MLD and other dose constraints for organs at risk, and to maximize the target generalized equivalent uniform dose (gEUD). To determine the benefit of dose rearrangement with perfusion SPECT, plans were reoptimized to minimize the generalized equivalent uniform functional dose (gEUfD) to the lung as the subsequent priority. Results When only physical MLD is minimized, lung gEUfD was 12.6 ± 4.9 Gy (6.3-21.7 Gy). When the dose is rearranged to minimize gEUfD directly in the optimization objective function, 10 of 15 cases showed a decrease in lung gEUfD of >20% (lung gEUfD mean 9.9 ± 4.3 Gy, range 2.1-16.2 Gy) while maintaining equivalent planning target volume coverage. Although all dose-limiting constraints remained unviolated, the dose rearrangement resulted in slight gEUD increases to the cord (5.4 ± 3.9 Gy), esophagus (3.0 ± 3.7 Gy), and heart (2.3 ± 2.6 Gy). Conclusions Priority-driven optimization in conjunction with perfusion SPECT permits image guided spatial dose redistribution within the lung and allows for a reduced dose to the functional lung without compromising target coverage or exceeding conventional limits for organs at risk.
Collapse
Affiliation(s)
- Martha M Matuszak
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan.,Department of Nuclear Engineering & Radiological Sciences, University of Michigan, Ann Arbor, Michigan
| | - Charles Matrosic
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan.,Department of Nuclear Engineering & Radiological Sciences, University of Michigan, Ann Arbor, Michigan
| | - David Jarema
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
| | - Daniel L McShan
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
| | - Matthew H Stenmark
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
| | - Dawn Owen
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
| | - Shruti Jolly
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
| | | | - Randall K Ten Haken
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
| |
Collapse
|
25
|
Berry SL, Boczkowski A, Ma R, Mechalakos J, Hunt M. Interobserver variability in radiation therapy plan output: Results of a single-institution study. Pract Radiat Oncol 2016; 6:442-449. [PMID: 27374191 DOI: 10.1016/j.prro.2016.04.005] [Citation(s) in RCA: 72] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2016] [Revised: 04/11/2016] [Accepted: 04/27/2016] [Indexed: 12/21/2022]
Abstract
PURPOSE We investigated the sources of variability in radiation therapy treatment plan output between planners within a single institution. METHODS AND MATERIALS Forty treatment planners across 5 campuses of an institution created a plan on the same thoracic esophagus patient computed tomography scan and structure set. Plans were scored and ranked based on the planner's adherence to an ordered list of target dose coverage and normal tissue evaluation criteria. A runs test was used to identify whether any of the studied planner qualities influenced the ranking. Spearman rank correlation was used to investigate whether plan score correlated with years of experience or planned monitor units. RESULTS The distribution of scores, ranging from 80.24 to 135.89, was negatively skewed (mean, 128.7; median, 131.5). No statistically significant relationship between plan score and campus (P = .193), job title (P = .174), previous outside experience (P = .611), or number of gantry angles (P = .156) was discovered. No statistical correlation between plan score and monitor unit or years of experience was found. CONCLUSIONS Despite clear and established critical organ dose criteria and well-documented planning guidelines, planning variation still occurs, even among members of the same institution. Because plan consistency does not seem to significantly correlate with experience, career path, or campus, investigation into alternate methods beyond additional education and training to reduce this variation, such as knowledge-based planning or advanced optimization techniques, is necessary.
Collapse
Affiliation(s)
- Sean L Berry
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York.
| | - Amanda Boczkowski
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Rongtao Ma
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - James Mechalakos
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Margie Hunt
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| |
Collapse
|
26
|
Baumann M, Krause M, Overgaard J, Debus J, Bentzen SM, Daartz J, Richter C, Zips D, Bortfeld T. Radiation oncology in the era of precision medicine. Nat Rev Cancer 2016; 16:234-49. [PMID: 27009394 DOI: 10.1038/nrc.2016.18] [Citation(s) in RCA: 514] [Impact Index Per Article: 64.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Technological advances and clinical research over the past few decades have given radiation oncologists the capability to personalize treatments for accurate delivery of radiation dose based on clinical parameters and anatomical information. Eradication of gross and microscopic tumours with preservation of health-related quality of life can be achieved in many patients. Two major strategies, acting synergistically, will enable further widening of the therapeutic window of radiation oncology in the era of precision medicine: technology-driven improvement of treatment conformity, including advanced image guidance and particle therapy, and novel biological concepts for personalized treatment, including biomarker-guided prescription, combined treatment modalities and adaptation of treatment during its course.
Collapse
Affiliation(s)
- Michael Baumann
- Department of Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden
- OncoRay - National Center for Radiation Research in Oncology (NCRO), Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, and Helmholtz-Zentrum Dresden-Rossendorf, Fetscherstrasse 74, 01307 Dresden
- National Center for Tumor Diseases (NCT), Fetscherstrasse 74, 01307 Dresden
- German Cancer Consortium (DKTK) Dresden, Germany
- German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
- Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiation Oncology, Bautzner Landstrasse 400, 01328 Dresden, Germany
| | - Mechthild Krause
- Department of Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden
- OncoRay - National Center for Radiation Research in Oncology (NCRO), Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, and Helmholtz-Zentrum Dresden-Rossendorf, Fetscherstrasse 74, 01307 Dresden
- National Center for Tumor Diseases (NCT), Fetscherstrasse 74, 01307 Dresden
- German Cancer Consortium (DKTK) Dresden, Germany
- German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
- Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiation Oncology, Bautzner Landstrasse 400, 01328 Dresden, Germany
| | - Jens Overgaard
- Department of Experimental Clinical Oncology, Aarhus University Hospital, Nørrebrogade 44, 8000 Aarhus C, Denmark
| | - Jürgen Debus
- German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), University of Heidelberg Medical School and German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Im Neuenheimer Feld 460, 69120 Heidelberg
- Heidelberg Ion Therapy Center (HIT), Department of Radiation Oncology, University of Heidelberg Medical School, Im Neuenheimer Feld 400, 69120 Heidelberg
- German Cancer Consortium (DKTK) Heidelberg, Germany
| | - Søren M Bentzen
- Department of Epidemiology and Public Health and Greenebaum Cancer Center, University of Maryland School of Medicine, 22 S Greene Street S9a03, Baltimore, Maryland 21201, USA
| | - Juliane Daartz
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital and Harvard Medical School, 1000 Blossom Street Cox 362, Boston, Massachusetts 02114, USA
| | - Christian Richter
- Department of Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden
- OncoRay - National Center for Radiation Research in Oncology (NCRO), Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, and Helmholtz-Zentrum Dresden-Rossendorf, Fetscherstrasse 74, 01307 Dresden
- National Center for Tumor Diseases (NCT), Fetscherstrasse 74, 01307 Dresden
- German Cancer Consortium (DKTK) Dresden, Germany
- German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
| | - Daniel Zips
- German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
- German Cancer Consortium Tübingen, Postfach 2669, 72016 Tübingen
- Department of Radiation Oncology, Faculty of Medicine and University Hospital Tübingen, Eberhard Karls Universität Tübingen, Hoppe-Seyler-Strasse 3, 72016 Tübingen, Germany
| | - Thomas Bortfeld
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital and Harvard Medical School, 1000 Blossom Street Cox 362, Boston, Massachusetts 02114, USA
| |
Collapse
|
27
|
Zarepisheh M, Uribe-Sanchez AF, Li N, Jia X, Jiang SB. A multicriteria framework with voxel-dependent parameters for radiotherapy treatment plan optimization. Med Phys 2014; 41:041705. [PMID: 24694125 DOI: 10.1118/1.4866886] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To establish a new mathematical framework for radiotherapy treatment optimization with voxel-dependent optimization parameters. METHODS In the treatment plan optimization problem for radiotherapy, a clinically acceptable plan is usually generated by an optimization process with weighting factors or reference doses adjusted for a set of the objective functions associated to the organs. Recent discoveries indicate that adjusting parameters associated with each voxel may lead to better plan quality. However, it is still unclear regarding the mathematical reasons behind it. Furthermore, questions about the objective function selection and parameter adjustment to assure Pareto optimality as well as the relationship between the optimal solutions obtained from the organ-based and voxel-based models remain unanswered. To answer these questions, the authors establish in this work a new mathematical framework equipped with two theorems. RESULTS The new framework clarifies the different consequences of adjusting organ-dependent and voxel-dependent parameters for the treatment plan optimization of radiation therapy, as well as the impact of using different objective functions on plan qualities and Pareto surfaces. The main discoveries are threefold: (1) While in the organ-based model the selection of the objective function has an impact on the quality of the optimized plans, this is no longer an issue for the voxel-based model since the Pareto surface is independent of the objective function selection and the entire Pareto surface could be generated as long as the objective function satisfies certain mathematical conditions; (2) All Pareto solutions generated by the organ-based model with different objective functions are parts of a unique Pareto surface generated by the voxel-based model with any appropriate objective function; (3) A much larger Pareto surface is explored by adjusting voxel-dependent parameters than by adjusting organ-dependent parameters, possibly allowing for the generation of plans with better trade-offs among different clinical objectives. CONCLUSIONS The authors have developed a mathematical framework for radiotherapy treatment optimization using voxel-based parameters. The authors can improve the plan quality by adjusting voxel-based weighting factors and exploring the unique and large Pareto surface which include all the Pareto surfaces that can be generated by organ-based model using different objective functions.
Collapse
Affiliation(s)
- Masoud Zarepisheh
- Center for Advanced Radiotherapy Technologies and Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California 92037-0843
| | - Andres F Uribe-Sanchez
- Center for Advanced Radiotherapy Technologies and Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California 92037-0843
| | - Nan Li
- Center for Advanced Radiotherapy Technologies and Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California 92037-0843
| | - Xun Jia
- Center for Advanced Radiotherapy Technologies and Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California 92037-0843
| | - Steve B Jiang
- Center for Advanced Radiotherapy Technologies and Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California 92037-0843
| |
Collapse
|
28
|
Kalantzis G, Apte A. A novel reduced-order prioritized optimization method for radiation therapy treatment planning. IEEE Trans Biomed Eng 2014; 61:1062-70. [PMID: 24658231 DOI: 10.1109/tbme.2013.2293779] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
In this study, a novel reduced order prioritized algorithm is presented for optimization in radiation therapy treatment planning. The proposed method consists of three stages. In the first stage, the intensity space was sampled by solving a series of unconstrained optimization problems. The objective function of the first stage is expressed as a scalarized weighted sum of partial objectives for the target and organ at risk. Latin hypercube sampling was utilized to define the weights for each run of the unconstrained optimizations. In the second stage, principal component analysis is applied to the solutions determined in the first stage to identify the major eigen modes in the intensities space, significantly reducing the number of independent variables. In the third stage, treatment planning goals/objectives are prioritized, and the problem is solved in the reduced order space. After each objective is optimized, that objective function is converted into a constraint for the lower-priority objectives. In the current formulation, a slip factor is used to relax the hard constraints for planning target volume (PTV) coverage. The applicability of the proposed method is demonstrated for one prostate and one lung intensity-modulated radiation therapy treatment plan. Upon completion of the sequential prioritized optimization, the mean dose at the rectum and bladder was reduced by 21.3% and 22.4%, respectively. Additionally, we investigated the effect of the slip factor 's' on PTV coverage and we found minimal degradation of the tumor dose (∼4%). Finally, the speed up factors upon the dimensionality reduction were as high as 49.9 without compromising the quality of the results.
Collapse
|
29
|
Schlaefer A, Viulet T, Muacevic A, Fürweger C. Multicriteria optimization of the spatial dose distribution. Med Phys 2014; 40:121720. [PMID: 24320506 DOI: 10.1118/1.4828840] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Treatment planning for radiation therapy involves trade-offs with respect to different clinical goals. Typically, the dose distribution is evaluated based on few statistics and dose-volume histograms. Particularly for stereotactic treatments, the spatial dose distribution represents further criteria, e.g., when considering the gradient between subregions of volumes of interest. The authors have studied how to consider the spatial dose distribution using a multicriteria optimization approach. METHODS The authors have extended a stepwise multicriteria optimization approach to include criteria with respect to the local dose distribution. Based on a three-dimensional visualization of the dose the authors use a software tool allowing interaction with the dose distribution to map objectives with respect to its shape to a constrained optimization problem. Similarly, conflicting criteria are highlighted and the planner decides if and where to relax the shape of the dose distribution. RESULTS To demonstrate the potential of spatial multicriteria optimization, the tool was applied to a prostate and meningioma case. For the prostate case, local sparing of the rectal wall and shaping of a boost volume are achieved through local relaxations and while maintaining the remaining dose distribution. For the meningioma, target coverage is improved by compromising low dose conformality toward noncritical structures. A comparison of dose-volume histograms illustrates the importance of spatial information for achieving the trade-offs. CONCLUSIONS The results show that it is possible to consider the location of conflicting criteria during treatment planning. Particularly, it is possible to conserve already achieved goals with respect to the dose distribution, to visualize potential trade-offs, and to relax constraints locally. Hence, the proposed approach facilitates a systematic exploration of the optimal shape of the dose distribution.
Collapse
Affiliation(s)
- Alexander Schlaefer
- Medical Robotics Group, Universität zu Lübeck, Lübeck 23562, Germany and Institute of Medical Technology, Hamburg University of Technology, Hamburg 21073, Germany
| | | | | | | |
Collapse
|
30
|
Lin KM, Simpson J, Sasso G, Raith A, Ehrgott M. Quality assessment for VMAT prostate radiotherapy planning based on data envelopment analysis. Phys Med Biol 2013; 58:5753-69. [PMID: 23912157 DOI: 10.1088/0031-9155/58/16/5753] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The majority of commercial radiotherapy treatment planning systems requires planners to iteratively adjust the plan parameters in order to find a satisfactory plan. This iterative trial-and-error nature of radiotherapy treatment planning results in an inefficient planning process and in order to reduce such inefficiency, plans can be accepted without achieving the best attainable quality. We propose a quality assessment method based on data envelopment analysis (DEA) to address this inefficiency. This method compares a plan of interest to a set of past delivered plans and searches for evidence of potential further improvement. With the assistance of DEA, planners will be able to make informed decisions on whether further planning is required and ensure that a plan is only accepted when the plan quality is close to the best attainable one. We apply the DEA method to 37 prostate plans using two assessment parameters: rectal generalized equivalent uniform dose (gEUD) as the input and D95 (the minimum dose that is received by 95% volume of a structure) of the planning target volume (PTV) as the output. The percentage volume of rectum overlapping PTV is used to account for anatomical variations between patients and is included in the model as a non-discretionary output variable. Five plans that are considered of lesser quality by DEA are re-optimized with the goal to further improve rectal sparing. After re-optimization, all five plans improve in rectal gEUD without clinically considerable deterioration of the PTV D95 value. For the five re-optimized plans, the rectal gEUD is reduced by an average of 1.84 Gray (Gy) with only an average reduction of 0.07 Gy in PTV D95. The results demonstrate that DEA can correctly identify plans with potential improvements in terms of the chosen input and outputs.
Collapse
Affiliation(s)
- Kuan-Min Lin
- Department of Engineering Science, University of Auckland, 70 Symonds Street, Auckland, New Zealand.
| | | | | | | | | |
Collapse
|
31
|
Salari E, Unkelbach J. A column-generation-based method for multi-criteria direct aperture optimization. Phys Med Biol 2013; 58:621-39. [PMID: 23318527 DOI: 10.1088/0031-9155/58/3/621] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Navigation-based multi-criteria optimization has been introduced to radiotherapy planning in order to allow the interactive exploration of trade-offs between conflicting clinical goals. However, this has been mainly applied to fluence map optimization. The subsequent leaf sequencing step may cause dose discrepancy, leading to human iteration loops in the treatment planning process that multi-criteria methods were meant to avoid. To circumvent this issue, this paper investigates the application of direct aperture optimization methods in the context of multi-criteria optimization. We develop a solution method to directly obtain a collection of apertures that can adequately span the entire Pareto surface. To that end, we extend the column generation method for direct aperture optimization to a multi-criteria setting in which apertures that can improve the entire Pareto surface are sequentially identified and added to the treatment plan. Our proposed solution method can be embedded in a navigation-based multi-criteria optimization framework, in which the treatment planner explores the trade-off between treatment objectives directly in the space of deliverable apertures. Our solution method is demonstrated for a paraspinal case where the trade-off between target coverage and spinal-cord sparing is studied. The computational results validate that our proposed method obtains a balanced approximation of the Pareto surface over a wide range of clinically relevant plans.
Collapse
Affiliation(s)
- Ehsan Salari
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.
| | | |
Collapse
|
32
|
Craft D, Richter C. Deliverable navigation for multicriteria step and shoot IMRT treatment planning. Phys Med Biol 2012; 58:87-103. [PMID: 23221364 DOI: 10.1088/0031-9155/58/1/87] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
We consider Pareto surface based multi-criteria optimization for step and shoot IMRT planning. By analyzing two navigation algorithms, we show both theoretically and in practice that the number of plans needed to form convex combinations of plans during navigation can be kept small (much less than the theoretical maximum number needed in general, which is equal to the number of objectives for on-surface Pareto navigation). Therefore a workable approach for directly deliverable navigation in this setting is to segment the underlying Pareto surface plans and then enforce the mild restriction that only a small number of these plans are active at any time during plan navigation, thus limiting the total number of segments used in the final plan.
Collapse
Affiliation(s)
- David Craft
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA, USA.
| | | |
Collapse
|
33
|
Fredriksson A. Automated improvement of radiation therapy treatment plans by optimization under reference dose constraints. Phys Med Biol 2012; 57:7799-811. [DOI: 10.1088/0031-9155/57/23/7799] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
34
|
Long T, Matuszak M, Feng M, Fraass BA, Ten Haken RK, Romeijn HE. Sensitivity analysis for lexicographic ordering in radiation therapy treatment planning. Med Phys 2012; 39:3445-55. [PMID: 22755724 DOI: 10.1118/1.4720218] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To introduce a method to efficiently identify and calculate meaningful tradeoffs between criteria in an interactive IMRT treatment planning procedure. The method provides a systematic approach to developing high-quality radiation therapy treatment plans. METHODS Treatment planners consider numerous dosimetric criteria of varying importance that, when optimized simultaneously through multicriteria optimization, yield a Pareto frontier which represents the set of Pareto-optimal treatment plans. However, generating and navigating this frontier is a time-consuming, nontrivial process. A lexicographic ordering (LO) approach to IMRT uses a physician's criteria preferences to partition the treatment planning decisions into a multistage treatment planning model. Because the relative importance of criteria optimized in the different stages may not necessarily constitute a strict prioritization, the authors introduce an interactive process, sensitivity analysis in lexicographic ordering (SALO), to allow the treatment planner control over the relative sequential-stage tradeoffs. By allowing this flexibility within a structured process, SALO implicitly restricts attention to and allows exploration of a subset of the Pareto efficient frontier that the physicians have deemed most important. RESULTS Improvements to treatment plans over a LO approach were found by implementing the SALO procedure on a brain case and a prostate case. In each stage, a physician assessed the tradeoff between previous stage and current stage criteria. The SALO method provided critical tradeoff information through curves approximating the relationship between criteria, which allowed the physician to determine the most desirable treatment plan. CONCLUSIONS The SALO procedure provides treatment planners with a directed, systematic process to treatment plan selection. By following a physician's prioritization, the treatment planner can avoid wasting effort considering clinically inferior treatment plans. The planner is guided by criteria importance, but given the information necessary to accurately adjust the relative importance at each stage. Through these attributes, the SALO procedure delivers an approach well balanced between efficiency and flexibility.
Collapse
Affiliation(s)
- T Long
- Department of Industrial and Operations Engineering, University of Michigan, 1205 Beal Avenue, Ann Arbor, MI 48109-2117, USA
| | | | | | | | | | | |
Collapse
|
35
|
Holdsworth C, Kim M, Liao J, Phillips M. The use of a multiobjective evolutionary algorithm to increase flexibility in the search for better IMRT plans. Med Phys 2012; 39:2261-74. [PMID: 22482647 DOI: 10.1118/1.3697535] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To evaluate how a more flexible and thorough multiobjective search of feasible IMRT plans affects performance in IMRT optimization. METHODS A multiobjective evolutionary algorithm (MOEA) was used as a tool to investigate how expanding the search space to include a wider range of penalty functions affects the quality of the set of IMRT plans produced. The MOEA uses a population of IMRT plans to generate new IMRT plans through deterministic minimization of recombined penalty functions that are weighted sums of multiple, tissue-specific objective functions. The quality of the generated plans are judged by an independent set of nonconvex, clinically relevant decision criteria, and all dominated plans are eliminated. As this process repeats itself, better plans are produced so that the population of IMRT plans will approach the Pareto front. Three different approaches were used to explore the effects of expanding the search space. First, the evolutionary algorithm used genetic optimization principles to search by simultaneously optimizing both the weights and tissue-specific dose parameters in penalty functions. Second, penalty function parameters were individually optimized for each voxel in all organs at risk (OARs) in the MOEA. Finally, a heuristic voxel-specific improvement (VSI) algorithm that can be used on any IMRT plan was developed that incrementally improves voxel-specific penalty function parameters for all structures (OARs and targets). Different approaches were compared using the concept of domination comparison applied to the sets of plans obtained by multiobjective optimization. RESULTS MOEA optimizations that simultaneously searched both importance weights and dose parameters generated sets of IMRT plans that were superior to sets of plans produced when either type of parameter was fixed for four example prostate plans. The amount of improvement increased with greater overlap between OARs and targets. Allowing the MOEA to search for voxel-specific penalty functions improved results for simple cases with three structures but did not improve results for a more complex case with seven structures. For this modification, the amount of improvement increased with less overlap between OARs and targets. The voxel-specific improvement algorithm improved results for all cases, and its clinical relevance was demonstrated in a complex prostate and a very complex head and neck case. CONCLUSIONS Using an evolutionary algorithm as a tool, it was found that allowing more flexibility in the search space enhanced performance. The two strategies of (a) varying the weights and reference doses in the objective function and (b) removing the constraint of equal penalties for all voxels in a structure both generated sets of plans that dominated sets of plans considered to be "Pareto optimal" within the conventional, more limited search space. When considering voxel-specific objectives, the very large search space can lead to convergence problems in the MOEA for complex cases, but this is not an issue for the VSI algorithm.
Collapse
Affiliation(s)
- Clay Holdsworth
- Department of Radiation Oncology, University of Washington, Seattle, WA 98195-6043, USA.
| | | | | | | |
Collapse
|
36
|
Feng M, Demiroz C, Vineberg KA, Eisbruch A, Balter JM. Normal tissue anatomy for oropharyngeal cancer: contouring variability and its impact on optimization. Int J Radiat Oncol Biol Phys 2012; 84:e245-9. [PMID: 22583602 DOI: 10.1016/j.ijrobp.2012.03.031] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2011] [Revised: 02/06/2012] [Accepted: 03/10/2012] [Indexed: 11/17/2022]
Abstract
PURPOSE To evaluate the variability of organ at risk (OAR) delineation and the resulting impact on intensity modulated radiation therapy (IMRT) treatment plan optimization in head-and-neck cancer. METHODS AND MATERIALS An expert panel of 3 radiation oncologists jointly delineated OARs, including the parotid and submandibular glands (SM), pharyngeal constrictors (PC), larynx, and glottis (GL), in 10 patients with advanced oropharynx cancer in 3 contouring sessions, spaced at least 1 week apart. Contour variability and uncertainty, as well as their dosimetric impact on IMRT planning for each case, were assessed. RESULTS The mean difference in total volume for each OAR was 1 cm(3) (σ 0.5 cm(3)). Mean fractional overlap was 0.7 (σ 0.1) and was highest (0.8) for the larynx and bilateral SMs and parotids and lowest (0.5) for PC. There were considerable spatial differences in contours, with the ipsilateral parotid and PC displaying the most variability (0.9 cm), which was most prominent in cases in which tumors obliterated fat planes. Both SMs and GL had the smallest differences (0.5 cm). The mean difference in OAR dose was 0.9 Gy (range 0.6-1.1 Gy, σ 0.1 Gy), with the smallest difference for GL and largest for both SMs and the larynx. CONCLUSIONS Despite substantial difference in OAR contours, optimization was barely affected, with a 0.9-Gy mean difference between optimizations, suggesting relative insensitivity of dose distributions for IMRT of oropharynx cancer to the extent of OARs.
Collapse
Affiliation(s)
- Mary Feng
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109, USA.
| | | | | | | | | |
Collapse
|
37
|
Breedveld S, Storchi PRM, Voet PWJ, Heijmen BJM. iCycle: Integrated, multicriterial beam angle, and profile optimization for generation of coplanar and noncoplanar IMRT plans. Med Phys 2012; 39:951-63. [PMID: 22320804 DOI: 10.1118/1.3676689] [Citation(s) in RCA: 222] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To introduce iCycle, a novel algorithm for integrated, multicriterial optimization of beam angles, and intensity modulated radiotherapy (IMRT) profiles. METHODS A multicriterial plan optimization with iCycle is based on a prescription called wish-list, containing hard constraints and objectives with ascribed priorities. Priorities are ordinal parameters used for relative importance ranking of the objectives. The higher an objective priority is, the higher the probability that the corresponding objective will be met. Beam directions are selected from an input set of candidate directions. Input sets can be restricted, e.g., to allow only generation of coplanar plans, or to avoid collisions between patient/couch and the gantry in a noncoplanar setup. Obtaining clinically feasible calculation times was an important design criterium for development of iCycle. This could be realized by sequentially adding beams to the treatment plan in an iterative procedure. Each iteration loop starts with selection of the optimal direction to be added. Then, a Pareto-optimal IMRT plan is generated for the (fixed) beam setup that includes all so far selected directions, using a previously published algorithm for multicriterial optimization of fluence profiles for a fixed beam arrangement Breedveld et al. [Phys. Med. Biol. 54, 7199-7209 (2009)]. To select the next direction, each not yet selected candidate direction is temporarily added to the plan and an optimization problem, derived from the Lagrangian obtained from the just performed optimization for establishing the Pareto-optimal plan, is solved. For each patient, a single one-beam, two-beam, three-beam, etc. Pareto-optimal plan is generated until addition of beams does no longer result in significant plan quality improvement. Plan generation with iCycle is fully automated. RESULTS Performance and characteristics of iCycle are demonstrated by generating plans for a maxillary sinus case, a cervical cancer patient, and a liver patient treated with SBRT. Plans generated with beam angle optimization did better meet the clinical goals than equiangular or manually selected configurations. For the maxillary sinus and liver cases, significant improvements for noncoplanar setups were seen. The cervix case showed that also in IMRT with coplanar setups, beam angle optimization with iCycle may improve plan quality. Computation times for coplanar plans were around 1-2 h and for noncoplanar plans 4-7 h, depending on the number of beams and the complexity of the site. CONCLUSIONS Integrated beam angle and profile optimization with iCycle may result in significant improvements in treatment plan quality. Due to automation, the plan generation workload is minimal. Clinical application has started.
Collapse
Affiliation(s)
- Sebastiaan Breedveld
- Department of Radiation Oncology, Erasmus MC Rotterdam, Groene Hilledijk 301, 3075 EA Rotterdam, The Netherlands.
| | | | | | | |
Collapse
|
38
|
Abstract
Despite many studies over the last 3 decades that have attempted to explicitly quantify the decision-making process for radiotherapy treatment plan evaluation, judgments of an individual plan's degree of quality are still largely subjective and can show inter- and intra-practitioner variability even if the clinical treatment goals are the same. Several factors conspire to confound the full quantification of treatment plan quality, including uncertainties in dose response of cancerous and normal tissue, the rapid pace of new technology adoption, and the human component of treatment planning. However, new developments in clinical informatics and automation are lowering the bar for developing and implementing quantitative metrics into the treatment planning process. This review discusses general strategies for using quantitative metrics in the treatment planning process and presents a case study in intensity-modulated radiation therapy planning whereby control was established on a variable system via such techniques.
Collapse
Affiliation(s)
- Kevin L Moore
- Department of Radiation Oncology, Washington University School of Medicine, St Louis, MO 63110, USA.
| | | | | | | |
Collapse
|
39
|
Prioritized optimization in intensity modulated proton therapy. Z Med Phys 2012; 22:21-8. [DOI: 10.1016/j.zemedi.2011.05.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2011] [Revised: 05/06/2011] [Accepted: 05/11/2011] [Indexed: 11/20/2022]
|
40
|
Yager RR, Gumrah G, Reformat MZ. Using a web Personal Evaluation Tool – PET for lexicographic multi-criteria service selection. Knowl Based Syst 2011. [DOI: 10.1016/j.knosys.2011.02.004] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
41
|
Petit SF, Wu B, Kazhdan M, Dekker A, Simari P, Kumar R, Taylor R, Herman JM, McNutt T. Increased organ sparing using shape-based treatment plan optimization for intensity modulated radiation therapy of pancreatic adenocarcinoma. Radiother Oncol 2011; 102:38-44. [PMID: 21680036 DOI: 10.1016/j.radonc.2011.05.025] [Citation(s) in RCA: 85] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2011] [Revised: 04/18/2011] [Accepted: 05/03/2011] [Indexed: 10/18/2022]
Abstract
PURPOSE To develop a model to assess the quality of an IMRT treatment plan using data of prior patients with pancreatic adenocarcinoma. METHODS The dose to an organ at risk (OAR) depends in large part on its orientation and distance to the planning target volume (PTV). A database of 33 previously treated patients with pancreatic cancer was queried to find patients with less favorable PTV-OAR configuration than a new case. The minimal achieved dose among the selected patients should also be achievable for the OAR of the new case. This way the achievable doses to the OARs of 25 randomly selected pancreas cancer patients were predicted. The patients were replanned to verify if the predicted dose could be achieved. The new plans were compared to their original clinical plans. RESULTS The predicted doses were achieved within 1 and 2 Gy for more than 82% and 94% of the patients, respectively, and were a good approximation of the minimal achievable doses. The improvement after replanning was 1.4 Gy (range 0-4.6 Gy) and 1.7 Gy (range 0-6.3 Gy) for the mean dose to the liver and the kidneys, respectively, without compromising target coverage or increasing radiation dose to the bowel, cord or stomach. CONCLUSIONS The model could accurately predict the achievable doses, leading to a considerable decrease in dose to the OARs and an increase in treatment planning efficiency.
Collapse
Affiliation(s)
- Steven F Petit
- Department of Computer Science, Johns Hopkins University, Baltimore, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
42
|
Bortfeld T, Jeraj R. The physical basis and future of radiation therapy. Br J Radiol 2011; 84:485-98. [PMID: 21606068 PMCID: PMC3473639 DOI: 10.1259/bjr/86221320] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2010] [Revised: 12/23/2010] [Accepted: 01/06/2011] [Indexed: 12/25/2022] Open
Abstract
The remarkable progress in radiation therapy over the last century has been largely due to our ability to more effectively focus and deliver radiation to the tumour target volume. Physics discoveries and technology inventions have been an important driving force behind this progress. However, there is still plenty of room left for future improvements through physics, for example image guidance and four-dimensional motion management and particle therapy, as well as increased efficiency of more compact and cheaper technologies. Bigger challenges lie ahead of physicists in radiation therapy beyond the dose localisation problem, for example in the areas of biological target definition, improved modelling for normal tissues and tumours, advanced multicriteria and robust optimisation, and continuous incorporation of advanced technologies such as molecular imaging. The success of physics in radiation therapy has been based on the continued "fuelling" of the field with new discoveries and inventions from physics research. A key to the success has been the application of the rigorous scientific method. In spite of the importance of physics research for radiation therapy, too few physicists are currently involved in cutting-edge research. The increased emphasis on more "professionalism" in medical physics will tip the situation even more off balance. To prevent this from happening, we argue that medical physics needs more research positions, and more and better academic programmes. Only with more emphasis on medical physics research will the future of radiation therapy and other physics-related medical specialties look as bright as the past, and medical physics will maintain a status as one of the most exciting fields of applied physics.
Collapse
Affiliation(s)
- T Bortfeld
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, 30 Fruit St., Boston, MA 02114, USA.
| | | |
Collapse
|
43
|
Craft DL, Hong TS, Shih HA, Bortfeld TR. Improved planning time and plan quality through multicriteria optimization for intensity-modulated radiotherapy. Int J Radiat Oncol Biol Phys 2011; 82:e83-90. [PMID: 21300448 DOI: 10.1016/j.ijrobp.2010.12.007] [Citation(s) in RCA: 132] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2010] [Revised: 11/30/2010] [Accepted: 12/07/2010] [Indexed: 10/18/2022]
Abstract
PURPOSE To test whether multicriteria optimization (MCO) can reduce treatment planning time and improve plan quality in intensity-modulated radiotherapy (IMRT). METHODS AND MATERIALS Ten IMRT patients (5 with glioblastoma and 5 with locally advanced pancreatic cancers) were logged during the standard treatment planning procedure currently in use at Massachusetts General Hospital (MGH). Planning durations and other relevant planning information were recorded. In parallel, the patients were planned using an MCO planning system, and similar planning time data were collected. The patients were treated with the standard plan, but each MCO plan was also approved by the physicians. Plans were then blindly reviewed 3 weeks after planning by the treating physician. RESULTS In all cases, the treatment planning time was vastly shorter for the MCO planning (average MCO treatment planning time was 12 min; average standard planning time was 135 min). The physician involvement time in the planning process increased from an average of 4.8 min for the standard process to 8.6 min for the MCO process. In all cases, the MCO plan was blindly identified as the superior plan. CONCLUSIONS This provides the first concrete evidence that MCO-based planning is superior in terms of both planning efficiency and dose distribution quality compared with the current trial and error-based IMRT planning approach.
Collapse
Affiliation(s)
- David L Craft
- Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA.
| | | | | | | |
Collapse
|
44
|
Monshouwer R, Hoffmann AL, Kunze-Busch M, Bussink J, Kaanders JHAM, Huizenga H. A practical approach to assess clinical planning tradeoffs in the design of individualized IMRT treatment plans. Radiother Oncol 2010; 97:561-6. [PMID: 21074884 DOI: 10.1016/j.radonc.2010.10.019] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2010] [Revised: 08/18/2010] [Accepted: 10/02/2010] [Indexed: 10/18/2022]
Abstract
BACKGROUND AND PURPOSE To investigate the tradeoffs between organ at risk sparing and tumour coverage for IMRT treatment of lung tumours, and to develop a tool for clinical use to graphically represent these tradeoffs. MATERIAL AND METHODS For 5 patients with inoperable non-small cell lung cancer (NSCLC) different IMRT plans were generated using a standard TPS. The plans were automatically generated for a range of IMRT settings (weights and dose levels of the objective functions) and were systematically evaluated, focusing on the tradeoffs between organ at risk (OAR) dose and target coverage. A method to analyze and visualize planning tradeoffs was developed and evaluated. RESULTS Lung and oesophagus were identified as the critical organs at risk for NSCLC, the sparing of which strongly influences PTV coverage. Systematically analyzing the tradeoffs between these organs revealed that the sparing of these organs was approximately linearly related to PTV coverage parameters. Using this property, a tool was developed to graphically present the tradeoffs between the sparing of these organs at risk and the PTV coverage. The tool is an effective method to visualize the tradeoffs. CONCLUSIONS A tool was developed to assist IMRT plan design and selection. The clear presentation of the tradeoffs between OAR dose and coverage facilitates the optimization process and offers additional information to the clinician for a patient specific choice of the optimal IMRT plan.
Collapse
Affiliation(s)
- René Monshouwer
- Department of Radiation Oncology, Radboud University Nijmegen Medical Centre, The Netherlands.
| | | | | | | | | | | |
Collapse
|
45
|
Holdsworth C, Kim M, Liao J, Phillips MH. A hierarchical evolutionary algorithm for multiobjective optimization in IMRT. Med Phys 2010; 37:4986-97. [PMID: 20964218 DOI: 10.1118/1.3478276] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The current inverse planning methods for intensity modulated radiation therapy (IMRT) are limited because they are not designed to explore the trade-offs between the competing objectives of tumor and normal tissues. The goal was to develop an efficient multiobjective optimization algorithm that was flexible enough to handle any form of objective function and that resulted in a set of Pareto optimal plans. METHODS A hierarchical evolutionary multiobjective algorithm designed to quickly generate a small diverse Pareto optimal set of IMRT plans that meet all clinical constraints and reflect the optimal trade-offs in any radiation therapy plan was developed. The top level of the hierarchical algorithm is a multiobjective evolutionary algorithm (MOEA). The genes of the individuals generated in the MOEA are the parameters that define the penalty function minimized during an accelerated deterministic IMRT optimization that represents the bottom level of the hierarchy. The MOEA incorporates clinical criteria to restrict the search space through protocol objectives and then uses Pareto optimality among the fitness objectives to select individuals. The population size is not fixed, but a specialized niche effect, domination advantage, is used to control the population and plan diversity. The number of fitness objectives is kept to a minimum for greater selective pressure, but the number of genes is expanded for flexibility that allows a better approximation of the Pareto front. RESULTS The MOEA improvements were evaluated for two example prostate cases with one target and two organs at risk (OARs). The population of plans generated by the modified MOEA was closer to the Pareto front than populations of plans generated using a standard genetic algorithm package. Statistical significance of the method was established by compiling the results of 25 multiobjective optimizations using each method. From these sets of 12-15 plans, any random plan selected from a MOEA population had a 11.3% +/- 0.7% chance of dominating any random plan selected by a standard genetic package with 0.04% +/- 0.02% chance of domination in reverse. By implementing domination advantage and protocol objectives, small and diverse populations of clinically acceptable plans that approximated the Pareto front could be generated in a fraction of 1 h. Acceleration techniques implemented on both levels of the hierarchical algorithm resulted in short, practical runtimes for multiobjective optimizations. CONCLUSIONS The MOEA produces a diverse Pareto optimal set of plans that meet all dosimetric protocol criteria in a feasible amount of time. The final goal is to improve practical aspects of the algorithm and integrate it with a decision analysis tool or human interface for selection of the IMRT plan with the best possible balance of successful treatment of the target with low OAR dose and low risk of complication for any specific patient situation.
Collapse
Affiliation(s)
- Clay Holdsworth
- Department of Radiation Oncology, University of Washington Medical Center, Box 356043, Seattle, Washington 98195, USA.
| | | | | | | |
Collapse
|
46
|
Breedveld S, Storchi PRM, Heijmen BJM. The equivalence of multi-criteria methods for radiotherapy plan optimization. Phys Med Biol 2009; 54:7199-209. [PMID: 19920305 DOI: 10.1088/0031-9155/54/23/011] [Citation(s) in RCA: 75] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Several methods can be used to achieve multi-criteria optimization of radiation therapy treatment planning, which strive for Pareto-optimality. The property of the solution being Pareto optimal is desired, because it guarantees that no criteria can be improved without deteriorating another criteria. The most widely used methods are the weighted-sum method, in which the different treatment objectives are weighted, and constrained optimization methods, in which treatment goals are set and the algorithm has to find the best plan fulfilling these goals. The constrained method used in this paper, the 2p element of c (2-phase element-constraint) method is based on the element-constraint method, which generates Pareto-optimal solutions. Both approaches are uniquely related to each other. In this paper, we will show that it is possible to switch from the constrained method to the weighted-sum method by using the Lagrange multipliers from the constrained optimization problem, and vice versa by setting the appropriate constraints. In general, the theory presented in this paper can be useful in cases where a new situation is slightly different from the original situation, e.g. in online treatment planning, with deformations of the volumes of interest, or in automated treatment planning, where changes to the automated plan have to be made. An example of the latter is given where the planner is not satisfied with the result from the constrained method and wishes to decrease the dose in a structure. By using the Lagrange multipliers, a weighted-sum optimization problem is constructed, which generates a Pareto-optimal solution in the neighbourhood of the original plan, but fulfills the new treatment objectives.
Collapse
Affiliation(s)
- Sebastiaan Breedveld
- Department of Radiation Oncology, Erasmus MC Rotterdam, Groene Hilledijk 301, 3075 EA Rotterdam, The Netherlands.
| | | | | |
Collapse
|
47
|
Pardo-Montero J, Fenwick JD. An approach to multiobjective optimization of rotational therapy. Med Phys 2009; 36:3292-303. [PMID: 19673225 DOI: 10.1118/1.3151806] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Multiobjective optimization is used in radiotherapy, especially IMRT, to generate treatment plans which meet different objectives to varying extents. Trade-off surfaces can be constructed representing the gains and losses of different objectives when switching from one plan to another, and the planner can interactively explore different treatment possibilities without the need for reoptimization. In this work a method for the multiobjective optimization of rotational therapy is introduced. The proposed method is applied slice per slice and uses the geometry of the slice directly to construct several arcs, each conformally irradiating the tumor and blocking a number (0,1,2,...) of different organs at risk present in the treatment. The blocked arc dose distributions so obtained are quite inhomogeneous in the target. An algorithm, based on the iterative reconstruction of images from projections, has been developed to compensate for this inhomogeneity, leading to compensated blocked arcs which deliver more uniform target doses but still block critical structures. Different treatments can be obtained as linear combinations of these arcs, each involving different trade-offs among the objectives involved. The compensatory algorithm substantially improves the target dose uniformity of blocked arcs at the cost of slightly increasing the dose to the rest of the body, allowing delivery of good uniform dose distributions to the target without significantly irradiating the blocked organ(s). Trade-off surfaces are presented for slices containing a target and one or two critical structures. The method is directly implementable using axial or helical tomotherapy. Implementation for conventional linear accelerators will be more difficult because the number of arcs needed to deliver such treatments can be large, an issue to be explored in future work.
Collapse
Affiliation(s)
- Juan Pardo-Montero
- School of Cancer Studies, University of Liverpool, Liverpool L69 7ZE, United Kingdom.
| | | |
Collapse
|
48
|
Evaluating the relationships between rectal normal tissue complication probability and the portion of seminal vesicles included in the clinical target volume in intensity-modulated radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys 2009; 73:334-40. [PMID: 19147014 DOI: 10.1016/j.ijrobp.2008.09.025] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2008] [Revised: 09/11/2008] [Accepted: 09/23/2008] [Indexed: 11/24/2022]
Abstract
PURPOSE To compare dose-volume consequences of the inclusion of various portions of the seminal vesicles (SVs) in the clinical target volume (CTV) in intensity-modulated radiotherapy (IMRT) for patients with prostate cancer. METHODS AND MATERIALS For 10 patients with prostate cancer, three matched IMRT plans were generated, including 1 cm, 2 cm, or the entire SVs (SV1, SV2, or SVtotal, respectively) in the CTV. Prescription dose (79.2 Gy) and IMRT planning were according to the high-dose arm of the Radiation Therapy Oncology Group (RTOG) 0126 protocol. We compared plans for percentage of rectal volume receiving minimum doses of 60-80 Gy and for rectal normal tissue complication probability (NTCP[R]). RESULTS There was a detectable increase in rectal dose in SV2 and SVtotal compared with SV1. The magnitude of difference between plans was modest in the high-dose range. In 2 patients, there was underdosing of the planning target volume (PTV) because of constraints on rectal dose in the SVtotal plans. All other plans were compliant with RTOG 0126 protocol requirements. Mean NTCP increased from 14% to 17% and 18% for SV1, SV2, and SV total, respectively. The NTCP correlated with the size of PTV-rectum volume overlap (Pearson's r = 0.86; p < 0.0001), but not with SV volume. CONCLUSIONS Doubling (1 to 2 cm) or comprehensively increasing (1 cm to full SVs) SV volume included in the CTV for patients with prostate IMRT is achievable in the majority of cases without exceeding RTOG dose-volume limits or underdosing the PTV and results in only a moderate increase in NTCP.
Collapse
|
49
|
Multicriteria optimization in intensity-modulated radiation therapy treatment planning for locally advanced cancer of the pancreatic head. Int J Radiat Oncol Biol Phys 2008; 72:1208-14. [PMID: 18954714 DOI: 10.1016/j.ijrobp.2008.07.015] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2008] [Revised: 07/11/2008] [Accepted: 07/20/2008] [Indexed: 01/27/2023]
Abstract
PURPOSE Intensity-modulated radiation therapy (IMRT) affords the potential to decrease radiation therapy-associated toxicity by creating highly conformal dose distributions. However, the inverse planning process can create a suboptimal plan despite meeting all constraints. Multicriteria optimization (MCO) may reduce the time-consuming iteration loop necessary to develop a satisfactory plan while providing information regarding trade-offs between different treatment planning goals. In this exploratory study, we examine the feasibility and utility of MCO in physician plan selection in patients with locally advanced pancreatic cancer (LAPC). METHODS AND MATERIALS The first 10 consecutive patients with LAPC treated with IMRT were evaluated. A database of plans (Pareto surface) was created that met the inverse planning goals. The physician then navigated to an "optimal" plan from the point on the Pareto surface at which kidney dose was minimized. RESULTS Pareto surfaces were created for all 10 patients. A physician was able to select a plan from the Pareto surface within 10 minutes for all cases. Compared with the original (treated) IMRT plans, the plan selected from the Pareto surface had a lower stomach mean dose in 9 of 10 patients, although often at the expense of higher kidney dose than with the treated plan. CONCLUSION The MCO is feasible in patients with LAPC and allows the physician to choose a satisfactory plan quickly. Generally, when given the opportunity, the physician will choose a plan with a lower stomach dose. The MCO enables a physician to provide greater active clinical input into the IMRT planning process.
Collapse
|
50
|
Sobotta B, Söhn M, Pütz M, Alber M. Tools for the analysis of dose optimization: III. Pointwise sensitivity and perturbation analysis. Phys Med Biol 2008; 53:6337-43. [DOI: 10.1088/0031-9155/53/22/005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|