1
|
Huang H, Hsu P, Tsai S, Chuang Y, Chen D, Xu G, Chen C, Kuo Y, Huang C. High-Spatiotemporal-Resolution Ultrasound Flow Imaging to Determine Cerebrovascular Hemodynamics in Alzheimer's Disease Mice Model. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2302345. [PMID: 37964413 PMCID: PMC10724386 DOI: 10.1002/advs.202302345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 08/28/2023] [Indexed: 11/16/2023]
Abstract
Although the relationships of cerebrovascular hemodynamic dysfunction with neurodegenerative diseases remain unclear, many studies have indicated that poor cerebral perfusion accelerates the progression of neurodegenerative diseases, such as Alzheimer's disease (AD). Small animal models are widely used in AD research. However, providing an imaging modality with a high spatiotemporal resolution and sufficiently large field of view to assess cerebrovascular hemodynamics in vivo remains a challenge. The present study proposes a novel technique for high-spatiotemporal-resolution vector micro-Doppler imaging (HVμDI) based on contrast-free ultrafast high frequency ultrasound imaging to visualize the cerebrovascular hemodynamics of the mouse, with a data acquisition time of 0.4 s, a minimal detectable vessel size of 38 µm, and a temporal resolution of 500 Hz. In vivo experiments are conducted on wild-type and AD mice. Cerebrovascular hemodynamics are quantified using the cerebral vascular density, diameter, velocity, tortuosity, cortical flow pulsatility, and instant flow direction variations. Results reveal that AD significantly change the cerebrovascular hemodynamics. HVμDI offers new opportunities for in vivo analysis of cerebrovascular hemodynamics in neurodegenerative pathologies in preclinical animal research.
Collapse
Affiliation(s)
- Hsin Huang
- Department of Biomedical EngineeringNational Cheng Kung UniversityTainan70101Taiwan
| | - Pei‐Ling Hsu
- Department of AnatomySchool of MedicineCollege of MedicineKaohsiung Medical UniversityKaohsiung80708Taiwan
- Department of Medical ResearchKaohsiung Medical University HospitalKaohsiung80708Taiwan
- Drug Development and Value Creation Research CenterKaohsiung Medical UniversityKaohsiung80708Taiwan
| | - Sheng‐Feng Tsai
- Department of Cell Biology and AnatomyCollege of MedicineNational Cheng Kung UniversityTainan70101Taiwan
- Institute of Basic Medical SciencesCollege of MedicineNational Cheng Kung UniversityTainan70101Taiwan
| | - Yi‐Hsiang Chuang
- Department of Biomedical EngineeringNational Cheng Kung UniversityTainan70101Taiwan
| | - De‐Quan Chen
- Department of Biomedical EngineeringNational Cheng Kung UniversityTainan70101Taiwan
| | - Guo‐Xuan Xu
- Department of Biomedical EngineeringNational Cheng Kung UniversityTainan70101Taiwan
| | - Chien Chen
- Department of Biomedical EngineeringNational Cheng Kung UniversityTainan70101Taiwan
| | - Yu‐Min Kuo
- Department of Cell Biology and AnatomyCollege of MedicineNational Cheng Kung UniversityTainan70101Taiwan
- Institute of Basic Medical SciencesCollege of MedicineNational Cheng Kung UniversityTainan70101Taiwan
| | - Chih‐Chung Huang
- Department of Biomedical EngineeringNational Cheng Kung UniversityTainan70101Taiwan
- Medical Device Innovation CenterNational Cheng Kung UniversityTainan70101Taiwan
| |
Collapse
|
2
|
Wu H, Tang Y, Zhang B, Klippel P, Jing Y, Yao J, Jiang X. Miniaturized Stacked Transducer for Intravascular Sonothrombolysis With Internal-Illumination Photoacoustic Imaging Guidance and Clot Characterization. IEEE Trans Biomed Eng 2023; 70:2279-2288. [PMID: 37022249 PMCID: PMC10399617 DOI: 10.1109/tbme.2023.3240725] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Thromboembolism in blood vessels can lead to stroke or heart attack and even sudden death unless brought under control. Sonothrombolysis enhanced by ultrasound contrast agents has shown promising outcome on effective treatment of thromboembolism. Intravascular sonothrombolysis was also reported recently with a potential for effective and safe treatment of deep thrombosis. Despite the promising treatment results, the treatment efficiency for clinical application may not be optimized due to the lack of imaging guidance and clot characterization during the thrombolysis procedure. In this paper, a miniaturized transducer was designed to have an 8-layer PZT-5A stacked with an aperture size of 1.4 × 1.4 mm2 and assembled in a customized two-lumen 10-Fr catheter for intravascular sonothrombolysis. The treatment process was monitored with internal-illumination photoacoustic tomography (II-PAT), a hybrid imaging modality that combines the rich contrast of optical absorption and the deep penetration of ultrasound detection. With intravascular light delivery using a thin optical fiber integrated with the intravascular catheter, II-PAT overcomes the penetration depth limited by strong optical attenuation of tissue. In-vitro PAT-guided sonothrombolysis experiments were carried out with synthetic blood clots embedded in tissue phantom. Clot position, shape, stiffness, and oxygenation level can be estimated by II-PAT at clinically relevant depth of ten centimeters. Our findings have demonstrated the feasibility of the proposed PAT-guided intravascular sonothrombolysis with real-time feedback during the treatment process.
Collapse
|
3
|
Mee-Inta O, Hsieh CF, Chen DQ, Fan CH, Chiang YY, Liu CC, Sze CI, Gean PW, Wu PC, Yang MS, Huang PS, Chieh Wu P, Kuo YM, Huang CC. High-frequency ultrasound imaging for monitoring the function of meningeal lymphatic system in mice. ULTRASONICS 2023; 131:106949. [PMID: 36773481 DOI: 10.1016/j.ultras.2023.106949] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 12/30/2022] [Accepted: 02/03/2023] [Indexed: 06/18/2023]
Abstract
The meningeal lymphatic system drains the cerebrospinal fluid from the subarachnoid space to the cervical lymphatic system, primarily to the deep cervical lymph nodes. Perturbations of the meningeal lymphatic system have been linked to various neurologic disorders. A method to specifically monitor the flow of meningeal lymphatic system in real time is unavailable. In the present study, we adopted the high-frequency ultrasound (HFUS) with 1,1'diocatadecyl-3,3,3',3'-tetramethylindocarbocyanine perchlorate (DiI)-loaded microbubble and FePt@PLGA nanoparticle contrast agents to evaluate the flow of the meningeal lymphatic system in 2-month-old mice. Statistical analysis was performed to identify changes of HFUS signals among the microbubbles, FePt@PLGA nanoparticles, and saline control groups. Approximately 15 min from the start of intracerebroventricular injection of contrast agents, their signals were evident at the deep cervical lymph nodes and lasted for at least 60 min. These signals were validated on the basis of the presence of DiI and Fe signals in the deep cervical lymph nodes. Ligation of afferent lymphatic vessels to the deep cervical lymph nodes eliminated the HFUS signals. Moreover, ablation of lymphatic vessels near the confluence of sinuses decreased the HFUS signals in the deep cervical lymph nodes. Glioma-bearing mice that exhibited reduced lymphatic vessel immunostaining signals near the confluence of sinuses had lowered HFUS signals in the deep cervical lymph nodes within 60 min. The proposed method provides a minimally invasive approach to monitor the qualities of the meningeal lymphatic system in real time as well as the progression of the meningeal lymphatic system in various brain disease animal models.
Collapse
Affiliation(s)
- Onanong Mee-Inta
- Institute of Basic Medical Sciences, College of Medicine, National Cheng Kung University, Tainan, Taiwan
| | - Chin-Fang Hsieh
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - De-Quan Chen
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Ching-Hsiang Fan
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan; Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan
| | - Yu-Yi Chiang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Chan-Chuan Liu
- Institute of Basic Medical Sciences, College of Medicine, National Cheng Kung University, Tainan, Taiwan; National Institute of Cancer Research, National Health Research Institutes, Tainan, Taiwan
| | - Chun-I Sze
- Institute of Basic Medical Sciences, College of Medicine, National Cheng Kung University, Tainan, Taiwan; Department of Cell Biology and Anatomy, College of Medicine, National Cheng Kung University, Tainan, Taiwan; Department of Pathology, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan
| | - Po-Wu Gean
- Institute of Basic Medical Sciences, College of Medicine, National Cheng Kung University, Tainan, Taiwan; Department of Pharmacology, College of Medicine, National Cheng Kung University, Tainan, Taiwan
| | - Ping-Ching Wu
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan; Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan; Institute of Oral Medicine and Department of Stomatology, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University Tainan, Taiwan; Center of Applied Nanomedicine, National Cheng Kung University, Tainan, Taiwan
| | - Mon-Shieh Yang
- College of Science, National Cheng Kung University, Tainan, Taiwan
| | - Po-Sheng Huang
- Department of Photonics, National Cheng Kung University, Tainan, Taiwan
| | - Pin Chieh Wu
- Department of Photonics, National Cheng Kung University, Tainan, Taiwan
| | - Yu-Min Kuo
- Institute of Basic Medical Sciences, College of Medicine, National Cheng Kung University, Tainan, Taiwan; Department of Cell Biology and Anatomy, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
| | - Chih-Chung Huang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan; Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan.
| |
Collapse
|
4
|
Yeh YW, Huang CC, Kuo WS, Liao TL, Tsai TL, Wu PC. Multifunctional Hydrogel Dressing That Carries Three Antibiotics Simultaneously and Enables Real-Time Ultrasound Bacterial Colony Detection. ACS OMEGA 2023; 8:10278-10287. [PMID: 36969425 PMCID: PMC10034778 DOI: 10.1021/acsomega.2c07806] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 03/03/2023] [Indexed: 06/18/2023]
Abstract
We have developed a multifunctional hydrogel that can carry three synergistic antibiotics commonly used in clinical practice. This hydrogel was discovered to have drug encapsulation efficiencies of 94% for neomycin, 97% for bacitracin, and 88% for polymyxin B. Drug release data indicated that the release profiles of these three antibiotics were different. A swelling test demonstrated that the hydrogel absorbed liquid after the release of its antibiotics until it became saturated, which occurred within 48 h. Moreover, this hydrogel exhibited excellent antibacterial effects against Escherichia coli and Pseudomonas aeruginosa and biocompatibility; it can thus protect a wound from microbial invasion. When the alginate hydrogel is used to cover a wound, the wound can be checked for colonization at any time using ultrasound imaging; this can thus enable the prevention of wound biofilm formation in the early stages of infection. We evaluated the hydrogel against commercially available wound dressings and discovered that these wound dressings did not have the aforementioned desirable features. In conclusion, our multifunctional hydrogel can carry three types of antibiotics simultaneously and is a suitable medium through which an ultrasound can be performed to detect the growth of colonies in wounds. The hydrogel is expected to make a valuable contribution to the prevention of wound infections in the future.
Collapse
Affiliation(s)
- Yao-Wei Yeh
- Department
of Biomedical Engineering, National Cheng
Kung University, Tainan 701401, Taiwan
| | - Chih-Chung Huang
- Department
of Biomedical Engineering, National Cheng
Kung University, Tainan 701401, Taiwan
- Medical
Device Innovation Center, National Cheng
Kung University, Tainan 701401, Taiwan
| | - Wen-Shuo Kuo
- Center
for Allergy, Immunology and Microbiome (AIM), China Medical University Children’s Hospital/China Medical
University Hospital, China Medical University, Taichung 404327, Taiwan
| | - Tzu-Lung Liao
- Department
of Biomedical Engineering, National Cheng
Kung University, Tainan 701401, Taiwan
| | - Tsung-Lin Tsai
- Department
of Biomedical Engineering, National Cheng
Kung University, Tainan 701401, Taiwan
- Department
of Oncology, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan 701401, Taiwan
- Center
of Applied Nanomedicine, National Cheng
Kung University, Tainan 701401, Taiwan
| | - Ping-Ching Wu
- Department
of Biomedical Engineering, National Cheng
Kung University, Tainan 701401, Taiwan
- Medical
Device Innovation Center, National Cheng
Kung University, Tainan 701401, Taiwan
- Center
of Applied Nanomedicine, National Cheng
Kung University, Tainan 701401, Taiwan
- Institute
of Oral Medicine and Department of Stomatology, National Cheng Kung
University Hospital, College of Medicine, National Cheng Kung University, Tainan 701401, Taiwan
| |
Collapse
|
5
|
Sheng D, Lee HT, Huang FC. All-digital transmit beamformer for portable high-frequency ultrasound imaging systems. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2023; 94:034707. [PMID: 37012793 DOI: 10.1063/5.0128410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Accepted: 02/11/2023] [Indexed: 06/19/2023]
Abstract
To meet the requirements of high-frequency ultrasound imaging systems, a transmit-beamforming integrated circuit with higher delay resolution than conventional transmit-beamforming circuits, which are typically implemented using field-programmable gate array chips, is presented. It also requires smaller volumes, allowing for portable applications. Its proposed design includes two all-digital delay-locked loops providing a specified digital control code for a counter-based beamforming delay chain (CBDC) to generate stable and suitable delays for exciting the array transducer elements without variations in process, voltage, and temperature. Moreover, to maintain the duty cycle of long propagation signals, this novel CBDC requires only a few delay cells, significantly reducing hardware costs and power consumption. Simulations were conducted, revealing a maximum time delay of 451.9 ns with a time resolution of 652 ps and a maximum lateral resolution error of 0.04 mm at 6.8 mm.
Collapse
Affiliation(s)
- Duo Sheng
- Department of Electrical Engineering, Fu Jen Catholic University, New Taipei City 24205, Taiwan
| | - Hsin-Ting Lee
- Department of Electrical Engineering, Fu Jen Catholic University, New Taipei City 24205, Taiwan
| | - Fu-Chi Huang
- Department of Electrical Engineering, Fu Jen Catholic University, New Taipei City 24205, Taiwan
| |
Collapse
|
6
|
Cheng HF, Chiu WT, Lai YS, Truong TT, Lee PY, Huang CC. High-frequency noncontact low-intensity pulsed ultrasound modulates Ca 2+-dependent transcription factors contributing to cell migration. ULTRASONICS 2023; 127:106852. [PMID: 36201953 DOI: 10.1016/j.ultras.2022.106852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 08/02/2022] [Accepted: 09/16/2022] [Indexed: 06/16/2023]
Abstract
Chronic wounds have negative physical and psychological effects on patients and increase the health care burden. Consequently, chronic wound in the elderly population is an important issue. Ultrasound can be a great modality for treating chronic wounds because of its noninvasive and safety characteristics; it can accelerate in vitro and in vivo wound healing. In this study, we developed a novel noncontact ultrasound for wound treatment. We stimulated human epidermal keratinocyte migration using low-intensity pulsed ultrasound (LIPUS) with a noncontact transducer to avoid direct contact with the wound. We also compared the effects of 15-min contact and noncontact transducer stimulation, where a 1-MHz contact transducer (intensity = 40 or 200 mW/cm2) and a 0.45-MHz noncontact transducer (intensity = 30 mW/cm2) were used. Both contact and noncontact LIPUS considerably increased cell migration and activated the calcium (Ca2+)-dependent transcription factors cAMP-responsive element-binding protein (CREB) and nuclear factor of activated T cells (NFAT). Furthermore, noncontact transducer stimulation did not cause cell death or affect cell proliferation but significantly increased the Ca2+ influx-mediated intracellular Ca2+ levels. Ca2+-free medium and Ca2+ channel blockers effectively inhibited LIPUS-induced Ca2+-dependent transcription factor activation and cell migration.
Collapse
Affiliation(s)
- Hsiao-Fan Cheng
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 70101, Taiwan
| | - Wen-Tai Chiu
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 70101, Taiwan; Medical Device Innovation Center, National Cheng Kung University, Tainan 70101, Taiwan
| | - Yi-Shyun Lai
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 70101, Taiwan
| | - Thi-Thuyet Truong
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 70101, Taiwan
| | - Po-Yang Lee
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 70101, Taiwan
| | - Chih-Chung Huang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 70101, Taiwan; Medical Device Innovation Center, National Cheng Kung University, Tainan 70101, Taiwan.
| |
Collapse
|
7
|
Tsai WY, Hsueh YY, Chen PY, Hung KS, Huang CC. High-Frequency Ultrasound Elastography for Assessing Elastic Properties of Skin and Scars. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:1871-1880. [PMID: 35201987 DOI: 10.1109/tuffc.2022.3154235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Scars are a type of fibrous tissue that typically forms during the wound healing process to replace damaged skin. Because studies have indicated a high correlation between scar stiffness and clinical symptoms, assessing the mechanical properties of scar is crucial for determining an appropriate treatment strategy and evaluating the treatment's efficacy. Shear wave elastography (SWE) is a common technique for measuring tissue elasticity. Because scars are typically a few millimeters thick, they are thin-layer tissues, and therefore, the dispersion effect must be considered to accurately estimate their elasticity. In this study, high-frequency ultrasound (HFUS) elastography was proposed for estimating the elastic properties of scars by using the Lamb wave model (LWM). An external vibrator was used to generate elastic waves in scar tissue and skin, and the propagation of the elastic waves was tracked through 40-MHz ultrafast ultrasound imaging. The elasticity was estimated through shear wave models (SWMs) and LWMs. The effectiveness of using HFUS elastography was verified through phantom and human studies. The phantom experiments involved bulk phantoms with gelatin concentrations of 7% and 15% and 2-4-mm-thick thin-layer 15% gelatin phantoms. The studies of three patients with eight cases of scarring were also conducted. The phantom experimental results demonstrated that the elasticity estimation biases for the thin-layer mediums were approximately -36% to -50% and 3% to -9% in the SWMs and LWMs, respectively, and the estimated shear moduli were 12.8 ± 5.4 kPa and 74.8 ± 26.8 kPa for healthy skin and scar tissue, respectively. All the results demonstrated that the proposed HFUS elastography has a great potential for improving the accuracy of elasticity estimations in clinical dermatological diagnoses.
Collapse
|
8
|
Wu H, Zhang B, Huang CC, Peng C, Zhou Q, Jiang X. Ultrasound-Guided Intravascular Sonothrombolysis With a Dual Mode Ultrasound Catheter: In Vitro Study. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:1917-1925. [PMID: 35201986 PMCID: PMC9702596 DOI: 10.1109/tuffc.2022.3153929] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Thromboembolism in vessels often leads to stroke or heart attack and even sudden death unless brought under control. Sonothrombolysis based on ultrasound contrast agents has shown promising outcome in effective treatment of thromboembolism. Intravascular sonothrombolysis transducer was reported recently for unprecedented sonothrombolysis in vitro. However, it is necessary to provide an imaging guide during thrombolysis in clinical applications for optimal treatment efficiency. In this article, a dual mode ultrasound catheter was developed by combining a 16-MHz high-frequency element (imaging transducer) and a 220-kHz low-frequency element (treatment transducer) for sonothrombolysis in vitro. The treatment transducer was designed with a 20-layer PZT-5A stack with the aperture size of 1.2×1.2 mm2, and the imaging transducer with the aperture size of 1.2×1.2 mm2 was attached in front of the treatment transducer. Both transducers were assembled into a customized 2-lm 10-Fr catheter. In vitro experiment was carried out using a bovine blood clot. Imaging tests were conducted, showing that the backscattering signals can be obtained with a high signal-to-noise ratio (SNR) for the 16-MHz imaging transducer. Sonothrombolysis was performed successfully that the volume of clot was reduced significantly after the 30-min treatment. The size changes of clot were observed clearly using the 16-MHz M-mode imaging during the thrombolysis. The findings suggest that the proposed ultrasound-guided intravascular sonothrombolysis can be enhanced since the position of treatment transducer can be adjusted with the target at the clot due to the imaging guide.
Collapse
|
9
|
Qiu XR, Wang MT, Huang H, Kuo LC, Hsu HY, Yang TH, Su FC, Huang CC. Estimating the neovascularity of human finger tendon through high frequency ultrasound micro-Doppler imaging. IEEE Trans Biomed Eng 2022; 69:2667-2678. [PMID: 35192458 DOI: 10.1109/tbme.2022.3152151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE Neovascularization of injured tendons prolongs the proliferative phase of healing, but prolonged neovascularization may cause improper healing and pain. Currently, ultrasound Doppler imaging is used for measuring the neovascularization of injured tendons (e.g., Achilles tendon). However, the resolution of state-of-the-art clinical ultrasound machines is insufficient for visualizing the neovascularization in finger tendons. In this study, a high-resolution micro-Doppler imaging (HFDI) based on 40-MHz ultrafast ultrasound imaging was proposed for visualizing the neovascularization in injured finger tendons during multiple rehabilitation phases. METHOD The vessel visibility was enhanced through a block-wise singular value decomposition filter and several curvilinear structure enhancement strategies, including the bowler-hat transform and Hessian-based vessel enhancement filtering. HFDI was verified through small animal kidney and spleen imaging because the related vessel structure patterns of mice are well studied. Five patients with finger tendon injuries underwent HFDI examination at various rehabilitation phases after surgery (weeks 1156), and finger function evaluations were performed for comparisons. RESULTS The results of small animal experiments revealed that the proposed HFDI provides excellent microvasculature imaging performance; the contrast-to-noise ratio of HFDI was approximately 15 dB higher than that of the conventional singular value decomposition filter, and the minimum detectable vessel size for mouse kidney was 35 m without the use of contrast agent. In the human study, neovascularization was clearly observed in injured finger tendons during the early phase of healing (weeks 1121), but it regressed from week 52 to 56. Finger rehabilitation appears to help reduce neovascularization; neovascular density decreased by approximately 1.8%8.0% in participants after 4 weeks of rehabilitation. CONCLUSION The experimental results verified the performance of HFDI for microvasculature imaging and its potential for injured finger tendon evaluations.
Collapse
|
10
|
Wu K, Lang X, Zhang Y, Li Z, He B, Gao L, Chen J. Ultrasound simulation of blood with different red blood cell aggregations and concentrations. Biomed Mater Eng 2021; 33:235-257. [PMID: 34897078 DOI: 10.3233/bme-211340] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Considerable progress of ultrasound simulation on blood has enhanced the characterizing of red blood cell (RBC) aggregation. OBJECTIVE A novel simulation method aims at modeling the blood with different RBC aggregations and concentrations is proposed. METHODS The modeling process is as follows: (i) A three-dimensional scatterer model is first built by a mapping with a Hilbert space-filling curve from the one-dimensional scatterer distribution. (ii) To illustrate the relationship between the model parameters and the RBC aggregation level, a variety of blood samples are prepared and scanned to acquire their radiofrequency signals in-vitro. (iii) The model parameters are determined by matching the Nakagami-distribution characteristics of envelope signals simulated from the model with those measured from the blood samples. RESULTS Nakagami metrics m estimated from 15 kinds of blood samples (hematocrits of 20%, 40%, 60% and plasma concentrations of 15%, 30%, 45%, 60%, 75%) are compared with metrics estimated by their corresponding models (each with different eligible parameters). Results show that for the three hematocrit levels, the mean and standard deviation of the root-mean-squared deviations of m are 0.27 ± 0.0026, 0.16 ± 0.0021, 0.12 ± 0.0018 respectively. CONCLUSION The proposed simulation model provides a viable data source to evaluate the performance of the ultrasound-based methods for quantifying RBC aggregation.
Collapse
Affiliation(s)
- Keyan Wu
- Department of Electronic Engineering, Information School, Yunnan University, Kunming, Yunnan, China
| | - Xun Lang
- Department of Electronic Engineering, Information School, Yunnan University, Kunming, Yunnan, China
| | - Yufeng Zhang
- Department of Electronic Engineering, Information School, Yunnan University, Kunming, Yunnan, China
| | - Zhiyao Li
- The Third Affiliated Hospital of Kunming Medical University, Kunming, Yunnan, China
| | - Bingbing He
- Department of Electronic Engineering, Information School, Yunnan University, Kunming, Yunnan, China
| | - Lian Gao
- Department of Electronic Engineering, Information School, Yunnan University, Kunming, Yunnan, China
| | - Jianhua Chen
- Department of Electronic Engineering, Information School, Yunnan University, Kunming, Yunnan, China
| |
Collapse
|
11
|
Huang H, Chen PY, Huang CC. 40-MHz high-frequency vector Doppler imaging for superficial venous valve flow estimation. Med Phys 2020; 47:4020-4031. [PMID: 32609885 DOI: 10.1002/mp.14362] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 05/26/2020] [Accepted: 06/17/2020] [Indexed: 11/10/2022] Open
Abstract
PURPOSE Doppler ultrasound imaging has been used widely for diagnosing vascular diseases. Recently, vector Doppler imaging (VDI) has been proposed for visualizing the blood flow in all directions to yield more detailed information for estimating flow conditions. Increasing the resolution of VDI is important for the structural mapping of superficial vessels with microstructure. However, VDI that operates under a high-frequency ultrasound (HFUS; >30 MHz) is rare. In this study, a 40-MHz high-frequency VDI (HFVDI) based on ultrafast ultrasound imaging was developed to obtain the vector information of blood flow around the superficial venous valve. METHODS The use of HFUS imaging system causes an overload of data acquisition easily. In order to provide sufficient recording time, the frame rate should be reduced. Because the aliasing problem worsens due to a low frame rate when operating Doppler imaging, phase-unwrapping processing methods based on spatial and temporal continuities were applied. Flow phantom experiments were performed to validate the accuracy. In vivo experiments were performed on the valve of superficial veins of healthy volunteers. RESULTS The experimental results from the phantom study indicated that the error of velocity estimation was <10% in most cases. Dynamic changes of valve movements and flow conditions (including velocity profiles and vector) were observed. Because of the high resolution of HFVDI, the jet and vortex phenomena were observed between the leaflets and in the sinus pocket, respectively. CONCLUSIONS Flow velocities ranging from 2 to 15 mm/s were measured at different locations around the venous valve during the opening and closing phases. All the results indicated that HFVDI has the potential to be a useful tool for vessel duplex scanning.
Collapse
Affiliation(s)
- Hsin Huang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Pei-Yu Chen
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Chih-Chung Huang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.,Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan
| |
Collapse
|
12
|
Lee CA, Kong Q, Paeng DG. Depletion-model-based numerical simulation of the kinetics of red blood cell aggregation under sinusoidal pulsatile flow. Biorheology 2019; 1:1-14. [PMID: 30010095 DOI: 10.3233/bir-170147] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Previous numerical modeling studies on red blood cell (RBC) aggregation have elucidated the inverse relationship between shear rate and RBC aggregation under steady flow. However, information on the cyclic variation in RBC aggregation under pulsatile flow remains lacking. OBJECTIVE RBC aggregation was simulated to investigate the complex interrelationships among the parameters of RBC motion under pulsatile flow. METHODS A two-dimensional particle model was used to simulate RBC motion driven by hydrodynamic, aggregation, and elastic forces in a sinusoidal pulsatile flow field. The kinetics of RBCs motion was simulated on the basis of the depletion model. RESULTS The simulation results corresponded with previously obtained experimental results for the formation and destruction of RBC aggregates with a parabolic radial distribution during a pulsatile cycle. In addition, the results demonstrated that the cyclic variation in the mean aggregate size of RBCs increased as velocity amplitude increased from 1 cm/s to 3 cm/s under a mean steady flow of 2 cm/s, as mean steady flow velocity decreased from 6 cm/s to 2 cm/s under a velocity amplitude of 1.5 cm/s, and as stroke rate decreased from 180 beats per minute (bpm) to 60 bpm. CONCLUSIONS The present simulation results verified previous experimental results and improved the current understanding of the complex spatiotemporal changes experienced by RBC aggregates during a sinusoidal pulsatile cycle.
Collapse
Affiliation(s)
- Cheong-Ah Lee
- Department of Ocean System Engineering, Jeju National University, Jeju, Korea
| | - Qi Kong
- Department of Ocean System Engineering, Jeju National University, Jeju, Korea
| | - Dong-Guk Paeng
- Department of Ocean System Engineering, Jeju National University, Jeju, Korea.,Department of Radiation Oncology, University of Virginia, Charlottesville, VA, USA
| |
Collapse
|
13
|
Li HC, Chen PY, Cheng HF, Kuo YM, Huang CC. In Vivo Visualization of Brain Vasculature in Alzheimer's Disease Mice by High-Frequency Micro-Doppler Imaging. IEEE Trans Biomed Eng 2019; 66:3393-3401. [PMID: 30872220 DOI: 10.1109/tbme.2019.2904702] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE Cerebrovascular disorders are associated with Alzheimer's disease (AD). Functional analysis of the cerebral vasculature requires an in vivo approach to visualize the blood flow in small animal brains. This paper proposes a high-frequency micro-Doppler imaging (HFμDI) technology for mapping mouse cerebral vasculature. METHODS HFμDI used a 40-MHz transducer with an ultrafast ultrasound imaging technology that enabled in vivo visualization of the mouse brain up to 3 mm in depth; furthermore, a minimal vessel diameter of 48 μm could be determined. RESULTS Animal experiments determined that the cortical and hippocampal vessel density in young wild-type (WT) mice was similar to that in middle-aged WT mice. However, compared with the vessel density in middle-aged WT mice, that in middle-aged mice with AD was significantly lower, particularly in the hippocampus. DISCUSSION In vivo observation of cerebral vasculature demonstrated the effectiveness of HFμDI for the preclinical study of AD, and a potential way for human diagnosis was provided.
Collapse
|
14
|
High-Resolution Shear Wave Imaging of the Human Cornea Using a Dual-Element Transducer. SENSORS 2018; 18:s18124244. [PMID: 30513950 PMCID: PMC6308409 DOI: 10.3390/s18124244] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Revised: 11/22/2018] [Accepted: 11/30/2018] [Indexed: 12/23/2022]
Abstract
Estimating the corneal elasticity can provide valuable information for corneal pathologies and treatments. Ophthalmologic pathologies will invariably cause changes to the elasticity of the cornea. For example, keratoconus and the phototoxic effects of ultraviolet radiation usually increase the corneal elasticity. This makes a quantitative estimation of the elasticity of the human cornea important for ophthalmic diagnoses. The present study investigated the use of a proposed high-resolution shear wave imaging (HR-SWI) method based on a dual-element transducer (comprising an 8-MHz element for pushing and a 32-MHz element for imaging) for measuring the group shear wave velocity (GSWV) of the human cornea. An empirical Young’s modulus formula was used to accurately convert the GSWV to Young’s modulus. Four quantitative parameters, bias, resolution, contrast, and contrast-to-noise ratio (CNR), were measured in gelatin phantoms with two different concentrations (3% and 7%) to evaluate the performance of HR-SWI. The biases of gelatin phantoms (3% and 7%) were 5.88% and 0.78%, respectively. The contrast and CNR were 0.76, 1.31 and 3.22, 2.43 for the two-side and two-layer phantoms, respectively. The measured image resolutions of HR-SWI in the lateral and axial directions were 72 and 140 μm, respectively. The calculated phase SWV (PSWV) and their corresponding Young’s modulus from six human donors were 2.45 ± 0.48 m/s (1600 Hz) and 11.52 ± 7.81 kPa, respectively. All the experimental results validated the concept of HR-SWI and its ability for measuring the human corneal elasticity.
Collapse
|
15
|
Gyawali P, Ziegler D, Cailhier JF, Denault A, Cloutier G. Quantitative Measurement of Erythrocyte Aggregation as a Systemic Inflammatory Marker by Ultrasound Imaging: A Systematic Review. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:1303-1317. [PMID: 29661483 DOI: 10.1016/j.ultrasmedbio.2018.02.020] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2017] [Revised: 02/21/2018] [Accepted: 02/28/2018] [Indexed: 06/08/2023]
Abstract
This systematic review is aimed at answering two questions: (i) Is erythrocyte aggregation a useful biomarker in assessing systemic inflammation? (ii) Does quantitative ultrasound imaging provide the non-invasive option to measure erythrocyte aggregation in real time? The search was executed through bibliographic electronic databases CINAHL, EMB Review, EMBASE, MEDLINE, PubMed and the grey literature. The majority of studies correlated elevated erythrocyte aggregation with inflammatory blood markers for several pathologic states. Some studies used "erythrocyte aggregation" as an established marker of systemic inflammation. There were limited but promising articles regarding the use of quantitative ultrasound spectroscopy to monitor erythrocyte aggregation. Similarly, there were limited studies that used other ultrasound techniques to measure systemic inflammation. The quantitative measurement of erythrocyte aggregation has the potential to be a routine clinical marker of inflammation as it can reflect the cumulative inflammatory dynamics in vivo, is relatively simple to measure, is cost-effective and has a rapid turnaround time. Technologies like quantitative ultrasound spectroscopy that can measure erythrocyte aggregation non-invasively and in real time may offer the advantage of continuous monitoring of the inflammation state and, thus, may help in rapid decision making in a critical care setup.
Collapse
Affiliation(s)
- Prajwal Gyawali
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montréal, Québec, Canada
| | - Daniela Ziegler
- Documentation Center, University of Montreal Hospital, Montréal, Québec, Canada
| | - Jean-François Cailhier
- University of Montreal Hospital Research Center (CRCHUM), Montréal, Québec, Canada; Department of Medicine, University of Montreal, Montréal, Québec, Canada
| | - André Denault
- University of Montreal Hospital, Montreal, Québec, Canada; Montreal Heart Institute, Montreal, Québec, Canada; Department of Anesthesiology, University of Montreal, Montréal, Québec, Canada
| | - Guy Cloutier
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montréal, Québec, Canada; Department of Radiology, Radio-Oncology and Nuclear Medicine, Montréal, Québec, Canada; Institute of Biomedical Engineering, University of Montreal, Montréal, Québec, Canada.
| |
Collapse
|
16
|
Evaluation of thrombolysis by using ultrasonic imaging: an in vitro study. Sci Rep 2015; 5:11669. [PMID: 26126487 PMCID: PMC4486939 DOI: 10.1038/srep11669] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2015] [Accepted: 06/01/2015] [Indexed: 12/31/2022] Open
Abstract
The hematocrit of a thrombus is a key factor associated with the susceptibility to thrombolysis. Ultrasonic imaging is currently the first-line screening tool for thrombus examinations. Different hematocrits result in different acoustical structures of thrombi, which alter the behavior of ultrasonic backscattering. This study explored the relationships among thrombolytic efficiencies, hematocrits, and ultrasonic parameters (the echo intensity and backscattered statistics). Porcine thrombi with different hematocrits, ranging from 0% to 50%, were induced in vitro. An ultrasonic scanner was used to scan thrombi and acquire raw image data for B-mode (echo intensity measurements) and Nakagami imaging (backscattered statistics analysis). Experiments on thrombolysis were performed using urokinase to explore the effect of the hematocrit on thrombolytic efficiency. Results showed that the weight loss ratio of thrombi exponentially decreased as the hematocrit increased from 0% to 50%. Compared with the echo intensity obtained from the conventional B-scan, the Nakagami parameter predicts the weight loss ratio, increasing from 0.6 to 1.2 as the weight loss ratio decreased from 0.67 to 0.26. The current findings suggest that using Nakagami imaging characterizing thrombi provides information of backscattered statistics, which may be associated with the thrombolytic efficiency.
Collapse
|
17
|
Huang CC, Chou HL, Chen PY. Measurement of the Doppler power of flowing blood using ultrasound Doppler devices. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:565-573. [PMID: 25542489 DOI: 10.1016/j.ultrasmedbio.2014.09.032] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2014] [Revised: 09/22/2014] [Accepted: 09/30/2014] [Indexed: 06/04/2023]
Abstract
Measurement of the Doppler power of signals backscattered from flowing blood (henceforth referred to as the Doppler power of flowing blood) and the echogenicity of flowing blood have been used widely to assess the degree of red blood cell (RBC) aggregation for more than 20 y. Many studies have used Doppler flowmeters based on an analogue circuit design to obtain the Doppler shifts in the signals backscattered from flowing blood; however, some recent studies have mentioned that the analogue Doppler flowmeter exhibits a frequency-response problem whereby the backscattered energy is lost at higher Doppler shift frequencies. Therefore, the measured Doppler power of flowing blood and evaluations of RBC aggregation obtained using an analogue Doppler device may be inaccurate. To overcome this problem, the present study implemented a field-programmable gate array-based digital pulsed-wave Doppler flowmeter to measure the Doppler power of flowing blood, in the aim of providing more accurate assessments of RBC aggregation. A clinical duplex ultrasound imaging system that can acquire pulsed-wave Doppler spectrograms is now available, but its usefulness for estimating the ultrasound scattering properties of blood is still in doubt. Therefore, the echogenicity and Doppler power of flowing blood under the same flow conditions were measured using a laboratory pulser-receiver system and a clinical ultrasound system, respectively, for comparisons. The experiments were carried out using porcine blood under steady laminar flow with both RBC suspensions and whole blood. The experimental results indicated that a clinical ultrasound system used to measure the Doppler spectrograms is not suitable for quantifying Doppler power. However, the Doppler power measured using a digital Doppler flowmeter can reveal the relationship between backscattering signals and the properties of blood cells because the effects of frequency response are eliminated. The measurements of the Doppler power and echogenicity of flowing blood were compared with those obtained in several previous studies.
Collapse
Affiliation(s)
- Chih-Chung Huang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.
| | - Hung-Lung Chou
- Department of Electrical Engineering, Fu Jen Catholic University, New Taipei City, Taiwan
| | - Pay-Yu Chen
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| |
Collapse
|
18
|
Bok TH, Li Y, Nam KH, Choi JC, Paeng DG. Feasibility Study of High-Frequency Ultrasonic Blood Imaging in Human Radial Artery. J Med Biol Eng 2015. [DOI: 10.1007/s40846-015-0001-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
19
|
Nam KH, Paeng DG. In vivo observation of the hypo-echoic "black hole" phenomenon in rat arterial bloodstream: a preliminary Study. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:1619-1628. [PMID: 24785440 DOI: 10.1016/j.ultrasmedbio.2014.01.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2013] [Revised: 12/26/2013] [Accepted: 01/27/2014] [Indexed: 06/03/2023]
Abstract
The "black hole," a hypo-echoic hole at the center of the bloodstream surrounded by a hyper-echoic zone in cross-sectional views, has been observed in ultrasound backscattering measurements of blood with red blood cell aggregation in in vitro studies. We investigated whether the phenomenon occurs in the in vivo arterial bloodstream of rats using a high-frequency ultrasound imaging system. Longitudinal and cross-sectional ultrasound images of the rat common carotid artery (CCA) and abdominal aorta were obtained using a 40-MHz ultrasound system. A high-frame-rate retrospective imaging mode was employed to precisely examine the dynamic changes in blood echogenicity in the arteries. When the imaging was performed with non-invasive scanning, blood echogenicity was very low in the CCA as compared with the surrounding tissues, exhibiting no hypo-echoic zone at the center of the vessel. Invasive imaging of the CCA by incising the skin and subcutaneous tissues at the imaging area provided clearer and brighter blood echo images, showing the "black hole" phenomenon near the center of the vessel in longitudinal view. The "black hole" was also observed in the abdominal aorta under direct imaging after laparotomy. The aortic "black hole" was clearly observed in both longitudinal and cross-sectional views. Although the "black hole" was always observed near the center of the arteries during the diastolic phase, it dissipated or was off-center along with the asymmetric arterial wall dilation at systole. In conclusion, we report the first in vivo observation of the hypo-echoic "black hole" caused by the radial variation of red blood cell aggregation in arterial bloodstream.
Collapse
Affiliation(s)
- Kweon-Ho Nam
- Department of Ocean System Engineering, Jeju National University, Jeju, South Korea
| | - Dong-Guk Paeng
- Department of Ocean System Engineering, Jeju National University, Jeju, South Korea; Interdisciplinary Postgraduate Program in Biomedical Engineering, Jeju National University, Jeju, South Korea.
| |
Collapse
|
20
|
Nam KH, Bok TH, Kong Q, Paeng DG. High spatial and temporal resolution observations of pulsatile changes in blood echogenicity in the common carotid artery of rats. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:1665-71. [PMID: 23830099 DOI: 10.1016/j.ultrasmedbio.2013.03.032] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2012] [Revised: 03/25/2013] [Accepted: 03/30/2013] [Indexed: 05/24/2023]
Abstract
Previous studies have found that ultrasound backscatter from blood in vascular flow systems varies under pulsatile flow, with the maximum values occurring during the systolic period. This phenomenon is of particular interest in hemorheology because it is contrary to the well-known fact that red blood cell (RBC) aggregation, which determines the intensity of ultrasound backscatter from blood, decreases at a high systolic shear rate. In the present study, a rat model was used to provide basic information on the characteristics of blood echogenicity in arterial blood flow to investigate the phenomenon of RBC aggregation under pulsatile flow. Blood echogenicity in the common carotid arteries of rats was measured using a high-frequency ultrasound imaging system with a 40-MHz probe. The electrocardiography-based kilohertz visualization reconstruction technique was employed to obtain high-temporal-resolution and high-spatial-resolution time-course B-mode cross-sectional and longitudinal images of the vessel. The experimental results indicate that blood echogenicity in rat carotid arteries varies during a cardiac cycle. Blood echogenicity tends to decrease during early systole and reaches its peak during late systole, followed by a slow decline thereafter. The time delay of the echogenicity peak from peak systole in the present results is the main difference from previous in vitro and in vivo observations of backscattering peaks during early systole, which may be caused by the very rapid heart rates and low RBC aggregation tendency of rats compared with humans and other mammalian species. The present study may provide useful information elucidating the characteristics of RBC aggregation in arterial blood flow.
Collapse
Affiliation(s)
- Kweon-Ho Nam
- Department of Ocean System Engineering, Jeju National University, Jeju, South Korea
| | | | | | | |
Collapse
|
21
|
Shih CC, Huang CC, Zhou Q, Shung KK. High-resolution acoustic-radiation-force-impulse imaging for assessing corneal sclerosis. IEEE TRANSACTIONS ON MEDICAL IMAGING 2013; 32:1316-24. [PMID: 23584258 PMCID: PMC3760240 DOI: 10.1109/tmi.2013.2256794] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
In ophthalmology, detecting the biomechanical properties of the cornea can provide valuable information about various corneal pathologies, including keratoconus and the phototoxic effects of ultraviolet radiation on the cornea. Also, the mechanical properties of the cornea can be used to evaluate the recovery from corneal refractive surgeries. Therefore, noninvasive and high-resolution estimation of the stiffness distribution in the cornea is important in ophthalmic diagnosis. The present study established a method for high-resolution acoustic-radiation-force-impulse (ARFI) imaging based on a dual-frequency confocal transducer in order to obtain a relative stiffness map, which was used to assess corneal sclerosis. An 11-MHz pushing element was used to induce localized displacements of tissue, which were monitored by a 48-MHz imaging element. Since the tissue displacements are directly correlated with the tissue elastic properties, the stiffness distribution in a tiny region of the cornea can be found by a mechanical B/D scan. The experimental system was verified using tissue-mimicking phantoms that included different geometric structures. Ex vivo cornea experiments were carried out using fresh porcine eyeballs. Corneas with localized sclerosis were created artificially by the injection of a formalin solution. The phantom experiments showed that the distributions of stiffness within different phantoms can be recognized clearly using ARFI imaging, and the measured lateral and axial resolutions of this imaging system were 177 and 153 μ m, respectively. The ex vivo experimental results from ARFI imaging showed that a tiny region of localized sclerosis in the cornea could be distinguished. All of the obtained results demonstrate that high-resolution ARFI imaging has considerable potential for the clinical diagnosis of corneal sclerosis.
Collapse
Affiliation(s)
- Cho-Chiang Shih
- Department of Electrical Engineering, Fu Jen Catholic University, New Taipei City 24205, Taiwan, and also with the Graduate Institute of Applied Science and Engineering, Fu Jen Catholic University, New Taipei City 24205, Taiwan
| | - Chih-Chung Huang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan City 701, Taiwan ()
| | - Qifa Zhou
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089 USA
| | - K. Kirk Shung
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089 USA
| |
Collapse
|
22
|
Huang CC, Liao CC, Lee PY, Shih CC. The effect of flow acceleration on the cyclic variation of blood echogenicity under pulsatile flow. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:670-80. [PMID: 23384462 DOI: 10.1016/j.ultrasmedbio.2012.10.018] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2012] [Revised: 09/22/2012] [Accepted: 10/28/2012] [Indexed: 05/24/2023]
Abstract
It has been shown that the echogenicity of blood varies during a flow cycle under pulsatile flow both in vitro and in vivo. In general, the echogenicity of flowing whole blood increases during the early systole phase and then reduces to a minimum at late diastole. While it has been postulated that this cyclic variation is associated with the dynamics of erythrocyte aggregation, the mechanisms underlying this increasing echogenicity with flow velocity remain uncertain. The effect of flow acceleration has also been proposed as an explanation for this phenomenon, but no specific experiments have been conducted to test this hypothesis. In addition, the influence of ultrasonic attenuation on the cyclic variation of echogenicity requires clarification. In the present study, a Couette flow system was designed to simulate blood flowing with different acceleration patterns, and the flow velocity, attenuation, and backscattering coefficient were measured synchronously from 20%- and 40%-hematocrit porcine whole blood and erythrocyte suspensions using 35-MHz ultrasound transducers. The results showed ultrasonic attenuation exerted only minor effects on the echogenicity of blood under pulsatile flow conditions. Cyclic variations of echogenicity were clearly observed for whole blood with a hematocrit of 40%, but no variations were apparent for erythrocyte suspensions. The echogenicity did not appear to be enhanced when instantaneous acceleration was applied to flowing blood in any case. These findings show that flow acceleration does not promote erythrocyte aggregation, even when a higher peak velocity is applied to the blood. Comparison of the results obtained with different accelerations revealed that the cyclic variation in echogenicity observed during pulsatile blood flow may be jointly attributable to the effect of shear rate and the distribution of erythrocyte on aggregation.
Collapse
Affiliation(s)
- Chih-Chung Huang
- Department of Electrical Engineering, Fu Jen Catholic University, New Taipei City, Taiwan.
| | | | | | | |
Collapse
|