Raghavi S, Sadoughi HR, Ravari ME, Behmadi M. Evaluation of Dose Calculation Algorithms Accuracy for ISOgray Treatment Planning System in Motorized Wedged Treatment Fields. JOURNAL OF MEDICAL SIGNALS & SENSORS 2024; 14:31. [PMID: 39691405 PMCID: PMC11651387 DOI: 10.4103/jmss.jmss_28_24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2024] [Revised: 07/17/2024] [Accepted: 08/12/2024] [Indexed: 12/19/2024]
Abstract
Background Different dose calculation methods vary in accuracy and speed. While most methods sacrifice precision for efficiency Monte Carlo (MC) simulation offers high accuracy but slower calculation. ISOgray treatment planning system (TPS) uses Clarkson, collapsed cone convolution (CCC), and fast Fourier transform (FFT) algorithms for dose distribution. This study's primary goal is to evaluate the dose calculation accuracy for ISOgray TPS algorithms in the presence of a wedge. Methods This study evaluates the dose calculation algorithms using the ISOgray TPS in the context of radiation therapy. The authors compare ISOgray TPS algorithms on an Elekta Compact LINAC through MC simulations. The study compares MC simulations for open and wedge fields with ISOgray algorithms by using gamma index analysis for validation. Results The percentage depth dose results for all open and wedge fields showed a more than 98% pass rate for points. However, there were differences in the dose profile gamma index results. Open fields passed the gamma index analysis in the in-plane direction, but not all points passed in the cross-plane direction. Wedge fields passed in the cross-plane direction, but not all in the in-plane direction, except for the Clarkson algorithms. Conclusion In all investigated algorithms, error increases in the penumbra areas, outside the field, and at cross-plane of open fields and in-plane direction of wedged fields. By increasing the wedge angle, the discrepancy between the TPS algorithms and MC simulations becomes more pronounced. This discrepancy is attributed to the increased presence of scattered photons and the variation in the delivered dose within the wedge field, consequently impacts the beam quality. While the CCC and FFT algorithms had better accuracy, the Clarkson algorithm, particularly at larger effective wedge angles, exhibited greater effectiveness than the two mentioned algorithms.
Collapse
Affiliation(s)
- Sajjad Raghavi
- Department of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran
| | - Hamid-Reza Sadoughi
- Department of Medical Physics and Radiology, Faculty of Paramedicine, North Khorasan University of Medical Sciences, Bojnurd, Iran
| | - Mohammad Ehsan Ravari
- Department of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran
- Cancer Research Center, Semnan University of Medical Sciences, Semnan, Iran
| | - Marziyeh Behmadi
- Department of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran
- Cancer Research Center, Semnan University of Medical Sciences, Semnan, Iran
| |
Collapse
|
2
|
Benzazon N, Carré A, de Kermenguy F, Niyoteka S, Maury P, Colnot J, M'hamdi M, Aichi ME, Veres C, Allodji R, de Vathaire F, Sarrut D, Journy N, Alapetite C, Grégoire V, Deutsch E, Diallo I, Robert C. Deep-Learning for Rapid Estimation of the Out-of-Field Dose in External Beam Photon Radiation Therapy - A Proof of Concept. Int J Radiat Oncol Biol Phys 2024; 120:253-264. [PMID: 38554830 DOI: 10.1016/j.ijrobp.2024.03.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 02/26/2024] [Accepted: 03/07/2024] [Indexed: 04/02/2024]
Abstract
PURPOSE The dose deposited outside of the treatment field during external photon beam radiation therapy treatment, also known as out-of-field dose, is the subject of extensive study as it may be associated with a higher risk of developing a second cancer and could have deleterious effects on the immune system that compromise the efficiency of combined radio-immunotherapy treatments. Out-of-field dose estimation tools developed today in research, including Monte Carlo simulations and analytical methods, are not suited to the requirements of clinical implementation because of their lack of versatility and their cumbersome application. We propose a proof of concept based on deep learning for out-of-field dose map estimation that addresses these limitations. METHODS AND MATERIALS For this purpose, a 3D U-Net, considering as inputs the in-field dose, as computed by the treatment planning system, and the patient's anatomy, was trained to predict out-of-field dose maps. The cohort used for learning and performance evaluation included 3151 pediatric patients from the FCCSS database, treated in 5 clinical centers, whose whole-body dose maps were previously estimated with an empirical analytical method. The test set, composed of 433 patients, was split into 5 subdata sets, each containing patients treated with devices unseen during the training phase. Root mean square deviation evaluated only on nonzero voxels located in the out-of-field areas was computed as performance metric. RESULTS Root mean square deviations of 0.28 and 0.41 cGy/Gy were obtained for the training and validation data sets, respectively. Values of 0.27, 0.26, 0.28, 0.30, and 0.45 cGy/Gy were achieved for the 6 MV linear accelerator, 16 MV linear accelerator, Alcyon cobalt irradiator, Mobiletron cobalt irradiator, and betatron device test sets, respectively. CONCLUSIONS This proof-of-concept approach using a convolutional neural network has demonstrated unprecedented generalizability for this task, although it remains limited, and brings us closer to an implementation compatible with clinical routine.
Collapse
Affiliation(s)
- Nathan Benzazon
- Unité Mixte de Recherche (UMR) 1030 Radiothérapie Moléculaire et Innovation Thérapeutique, ImmunoRadAI, Inserm, Université Paris-Saclay, Institut Gustave Roussy, Villejuif, France; Department of Radiation Oncology, Institut Gustave Roussy, Villejuif, France.
| | - Alexandre Carré
- Unité Mixte de Recherche (UMR) 1030 Radiothérapie Moléculaire et Innovation Thérapeutique, ImmunoRadAI, Inserm, Université Paris-Saclay, Institut Gustave Roussy, Villejuif, France; Department of Radiation Oncology, Institut Gustave Roussy, Villejuif, France
| | - François de Kermenguy
- Unité Mixte de Recherche (UMR) 1030 Radiothérapie Moléculaire et Innovation Thérapeutique, ImmunoRadAI, Inserm, Université Paris-Saclay, Institut Gustave Roussy, Villejuif, France; Department of Radiation Oncology, Institut Gustave Roussy, Villejuif, France
| | - Stéphane Niyoteka
- Unité Mixte de Recherche (UMR) 1030 Radiothérapie Moléculaire et Innovation Thérapeutique, ImmunoRadAI, Inserm, Université Paris-Saclay, Institut Gustave Roussy, Villejuif, France; Department of Radiation Oncology, Institut Gustave Roussy, Villejuif, France
| | - Pauline Maury
- Unité Mixte de Recherche (UMR) 1030 Radiothérapie Moléculaire et Innovation Thérapeutique, ImmunoRadAI, Inserm, Université Paris-Saclay, Institut Gustave Roussy, Villejuif, France; Department of Radiation Oncology, Institut Gustave Roussy, Villejuif, France
| | - Julie Colnot
- Unité Mixte de Recherche (UMR) 1030 Radiothérapie Moléculaire et Innovation Thérapeutique, ImmunoRadAI, Inserm, Université Paris-Saclay, Institut Gustave Roussy, Villejuif, France; Department of Radiation Oncology, Institut Gustave Roussy, Villejuif, France; THERYQ, PMB-Alcen, Peynier, France
| | - Meissane M'hamdi
- Unité Mixte de Recherche (UMR) 1030 Radiothérapie Moléculaire et Innovation Thérapeutique, ImmunoRadAI, Inserm, Université Paris-Saclay, Institut Gustave Roussy, Villejuif, France; Department of Radiation Oncology, Institut Gustave Roussy, Villejuif, France
| | - Mohammed El Aichi
- Unité Mixte de Recherche (UMR) 1030 Radiothérapie Moléculaire et Innovation Thérapeutique, ImmunoRadAI, Inserm, Université Paris-Saclay, Institut Gustave Roussy, Villejuif, France; Department of Radiation Oncology, Institut Gustave Roussy, Villejuif, France
| | - Cristina Veres
- Unité Mixte de Recherche (UMR) 1030 Radiothérapie Moléculaire et Innovation Thérapeutique, ImmunoRadAI, Inserm, Université Paris-Saclay, Institut Gustave Roussy, Villejuif, France; Department of Radiation Oncology, Institut Gustave Roussy, Villejuif, France
| | - Rodrigue Allodji
- Unité Mixte de Recherche (UMR) 1018 Centre de Recherche en épidémiologie et Santé des Populations (CESP), Radiation Epidemiology Team, Inserm, Université Paris-Saclay, Institut Gustave Roussy, Villejuif, France
| | - Florent de Vathaire
- Unité Mixte de Recherche (UMR) 1018 Centre de Recherche en épidémiologie et Santé des Populations (CESP), Radiation Epidemiology Team, Inserm, Université Paris-Saclay, Institut Gustave Roussy, Villejuif, France
| | - David Sarrut
- Université de Lyon; CREATIS; CNRS UMR5220; Inserm U1294; INSA-Lyon; Léon Bérard cancer center, Lyon, France
| | - Neige Journy
- Unité Mixte de Recherche (UMR) 1018 Centre de Recherche en épidémiologie et Santé des Populations (CESP), Radiation Epidemiology Team, Inserm, Université Paris-Saclay, Institut Gustave Roussy, Villejuif, France
| | | | - Vincent Grégoire
- Department of Radiation Oncology, centre Léon-Bérard, Lyon, France
| | - Eric Deutsch
- Unité Mixte de Recherche (UMR) 1030 Radiothérapie Moléculaire et Innovation Thérapeutique, ImmunoRadAI, Inserm, Université Paris-Saclay, Institut Gustave Roussy, Villejuif, France; Department of Radiation Oncology, Institut Gustave Roussy, Villejuif, France
| | - Ibrahima Diallo
- Unité Mixte de Recherche (UMR) 1030 Radiothérapie Moléculaire et Innovation Thérapeutique, ImmunoRadAI, Inserm, Université Paris-Saclay, Institut Gustave Roussy, Villejuif, France; Department of Radiation Oncology, Institut Gustave Roussy, Villejuif, France
| | - Charlotte Robert
- Unité Mixte de Recherche (UMR) 1030 Radiothérapie Moléculaire et Innovation Thérapeutique, ImmunoRadAI, Inserm, Université Paris-Saclay, Institut Gustave Roussy, Villejuif, France; Department of Radiation Oncology, Institut Gustave Roussy, Villejuif, France
| |
Collapse
|
3
|
Behmadi M, Toossi MTB, Nasseri S, Ravari ME, Momennezhad M, Gholamhosseinian H, Mohammadi M, Mdletshe S. Calculation of Organ Dose Distribution (in-field and Out-of-field) in Breast Cancer Radiotherapy on RANDO Phantom Using GEANT4 Application for Tomographic Emission (Gate) Monte Carlo Simulation. JOURNAL OF MEDICAL SIGNALS & SENSORS 2024; 14:18. [PMID: 39100743 PMCID: PMC11296572 DOI: 10.4103/jmss.jmss_25_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 02/02/2024] [Accepted: 03/05/2024] [Indexed: 08/06/2024]
Abstract
Introduction Organ dose distribution calculation in radiotherapy and knowledge about its side effects in cancer etiology is the most concern for medical physicists. Calculation of organ dose distribution for breast cancer treatment plans with Monte Carlo (MC) simulation is the main goal of this study. Materials and Methods Elekta Precise linear accelerator (LINAC) photon mode was simulated and verified using the GEANT4 application for tomographic emission. Eight different radiotherapy treatment plans on RANDO's phantom left breast were produced with the ISOgray treatment planning system (TPS). The simulated plans verified photon dose distribution in clinical tumor volume (CTV) with TPS dose volume histogram (DVH) and gamma index tools. To verify photon dose distribution in out-of-field organs, the point dose measurement results were compared with the same point doses in the MC simulation. Eventually, the DVHs for out-of-field organs that were extracted from the TPS and MC simulation were compared. Results Based on the implementation of gamma index tools with 2%/2 mm criteria, the simulated LINAC output demonstrated high agreement with the experimental measurements. Plan simulation for in-field and out-of-field organs had an acceptable agreement with TPS and experimental measurement, respectively. There was a difference between DVHs extracted from the TPS and MC simulation for out-of-field organs in low-dose parts. This difference is due to the inability of the TPS to calculate dose distribution in out-of-field organs. Conclusion and Discussion Based on the results, it was concluded that the treatment plans with the MC simulation have a high accuracy for the calculation of out-of-field dose distribution and could play a significant role in evaluating the important role of dose distribution for second primary cancer estimation.
Collapse
Affiliation(s)
- Marziyeh Behmadi
- Cancer Research Center, Semnan University of Medical Sciences, Semnan, Iran
- Department of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran
| | - Mohammad Taghi Bahreyni Toossi
- Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
- Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Shahrokh Nasseri
- Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
- Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mohammad Ehsan Ravari
- Cancer Research Center, Semnan University of Medical Sciences, Semnan, Iran
- Department of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran
| | - Mahdi Momennezhad
- Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Hamid Gholamhosseinian
- Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
- Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mohammad Mohammadi
- Department of Medical Physics, Royal Adelaide Hospital, Adelaide, Australia
| | - Sibusiso Mdletshe
- Department of Anatomy and Medical Imaging, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| |
Collapse
|
4
|
Mukwada G, Skorska M, Rowshanfarzad P, Ebert MA. Comparison of the accuracy of Monte Carlo and Ray Tracing dose calculation algorithms for multiple target brain treatments on CyberKnife. Phys Eng Sci Med 2023; 46:1477-1487. [PMID: 37552365 DOI: 10.1007/s13246-023-01312-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2023] [Accepted: 07/26/2023] [Indexed: 08/09/2023]
Abstract
Single plan multiple brain targets (MBT) stereotactic radiosurgery dose difference between Monte Carlo (MC) and Ray Tracing (RT) algorithms has not been studied. A retrospective study and dose measurements were performed to access factors influencing dose differences. Fifty-three RT treatment plans with a total of 209 brain metastases were extracted from Precision Treatment Planning System (TPS). These plans were generated using fixed cones and were delivered using the CyberKnife M6 system. The same treatment plans were recalculated using MC algorithm and keeping the beam parameters unchanged. MC calculated plan parameters were extracted and dose differences were normalised to MC calculated dose. Correlations were investigated. RT and MC calculated off-centre-ratio (OCR) and tissue-phantom-ratio (TPRs) were exported from the TPS and compared with measured. Plans with 5 gross tumour volumes (GTVs) were created on a phantom and dose measured using a CC04 ionisation chamber and microdiamond detector for comparison with calculated doses. Calculated and measured TPR agreed within ± 1% beyond depth of maximum dose. The OCR showed differences up to 4.3% in the penumbra and out-of-field (OOF) regions. Largest RT and MC calculated GTV mean dose difference was - 5.7%. An increase in the number of GTVs and reduction in the geometric separation of metastases were associated with increased differences between RT and MC calculated doses. In conclusion, calculated dose disagreement in MBT depends on the number of GTVs per plan, number of GTVs within a certain separation distance and plan complexity. MC dose calculation is recommended for complex CyberKnife SRS of MBT.
Collapse
Affiliation(s)
- Godfrey Mukwada
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Hospital Ave, Nedlands, WA, Australia.
- School of Physics, Mathematics and Computing, The University of Western Australia, Crawley, WA, Australia.
| | - Malgorzata Skorska
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Hospital Ave, Nedlands, WA, Australia
| | - Pejman Rowshanfarzad
- School of Physics, Mathematics and Computing, The University of Western Australia, Crawley, WA, Australia
| | - Martin A Ebert
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Hospital Ave, Nedlands, WA, Australia
- School of Physics, Mathematics and Computing, The University of Western Australia, Crawley, WA, Australia
- 5D Clinics, Claremont, WA, Australia
| |
Collapse
|
5
|
Aghdam SRH, Aghamiri SMR, Siavashpour Z, Malekie S, Dashtipoor MR. Assessment of out-of-field radiation doses for high dose per pulse intraoperative electron beam radiotherapy using TLD-100. Radiat Phys Chem Oxf Engl 1993 2023; 204:110652. [DOI: https:/doi.org/10.1016/j.radphyschem.2022.110652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/21/2023]
|
6
|
Attalla EM, Sinousy DM, Ibrahim HF, Elmekawy AF, Elhussiny FA. The accuracy of out of field dose calculations in commercial treatment planning system using GATE/GEANT4 Monte Carlo simulation. Radiat Phys Chem Oxf Engl 1993 2023. [DOI: 10.1016/j.radphyschem.2023.110772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
7
|
Aghdam SRH, Aghamiri SMR, Siavashpour Z, Malekie S, Dashtipoor MR. Assessment of out-of-field radiation doses for high dose per pulse intraoperative electron beam radiotherapy using TLD-100. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
8
|
Association between treatment-related lymphopenia and survival in glioblastoma patients following postoperative chemoradiotherapy. Strahlenther Onkol 2021; 198:448-457. [PMID: 34617129 PMCID: PMC9038819 DOI: 10.1007/s00066-021-01855-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Accepted: 08/17/2021] [Indexed: 12/20/2022]
Abstract
PURPOSE Our study investigated the association between treatment-related lymphopenia and overall survival (OS) in a series of glioblastoma (GBM) patients. We also explored clinical and dosimetric predictors of lymphocytes depletion. METHODS Between 2015 and 2019, 64 patients were treated at the same institution with postoperative chemoradiotherapy. Peripheral lymphocyte count (PLC) data and dose-volume histogram parameters were collected. Radiotherapy (RT) schedule consisted in standard total dose of 60 Gy in 30 daily fractions, with concomitant and adjuvant temozolomide (TMZ). Posttreatment acute absolute lymphopenia (nadir AAL) was calculated as a PLC lower than 1.0 × 103/mm3. Acute relative lymphopenia (ARL) was expressed by the nadir-PLC/baseline-PLC ratio < 0.5. Nadir-PLC was the lowest PLC registered between the end of RT and the first month of follow-up. Survival rates were estimated with Kaplan-Meier curves. Clinical and dosimetric variables related to AAL/ARL and OS were identified by univariate and multivariate analyses. RESULTS A total of 57 patients were eligible and included in the analyses. The median PLC was significantly decreased following chemoradiotherapy (2180/mm3 vs 900/mm3). Median OS was 16 months (range 5-55 months), with no significant difference between patients who developed nadir AAL and those who did not (16 months vs 16.5 months; p = 0.304). When considering ARL vs non-ARL, median OS was 14 months vs 26 months (p = 0.013), respectively. In multivariate Cox regression only age, sex, extent of surgery, access to adjuvant chemotherapy and brain D98% were independently associated with OS. CONCLUSION Although iatrogenic immunosuppression could be associated with inferior clinical outcomes, our data show that treatment-related lymphopenia does not adversely affect GBM survival. Prospective studies are required to confirm these findings.
Collapse
|
9
|
Out-of-field organ doses and associated risk of cancer development following radiation therapy with photons. Phys Med 2021; 90:73-82. [PMID: 34563834 DOI: 10.1016/j.ejmp.2021.09.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 09/06/2021] [Accepted: 09/13/2021] [Indexed: 11/21/2022] Open
Abstract
Innovations in cancer treatment have contributed to the improved survival rate of these patients. Radiotherapy is one of the main options for cancer management nowadays. High doses of ionizing radiation are usually delivered to the tumor site with high energy photon beams. However, the therapeutic radiation exposure may lead to second cancer induction. Moreover, the introduction of intensity-modulated radiation therapy over the last decades has increased the radiation dose to out-of-field organs compared to that from conventional irradiation. The increased organ doses might result in elevated probabilities for developing secondary malignancies to critical organs outside the treatment volume. The organ-specific dosimetry is considered necessary for the theoretical second cancer risk assessment and the proper analysis of data derived from epidemiological reports. This study reviews the methods employed for the measurement and calculation of out-of-field organ doses from exposure to photons and/or neutrons. The strengths and weaknesses of these dosimetric approaches are described in detail. This is followed by a review of the epidemiological data associated with out-of-field cancer risks. Previously published theoretical cancer risk estimates for adult and pediatric patients undergoing radiotherapy with conventional and advanced techniques are presented. The methodology for the theoretical prediction of the probability of carcinogenesis to out-of-field sites and the limitations of this approach are discussed. The article also focuses on the factors affecting the magnitude of the probability for developing radiotherapy-induced malignancies. The restriction of out-of-field doses and risks through the use of different types of shielding equipment is presented.
Collapse
|
10
|
Mazonakis M, Lyraraki E, Tolia M, Damilakis J. Risk for second bladder and rectal malignancies from cervical cancer irradiation. J Appl Clin Med Phys 2021; 22:103-109. [PMID: 34021692 PMCID: PMC8292701 DOI: 10.1002/acm2.13274] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 04/17/2021] [Accepted: 04/19/2021] [Indexed: 12/03/2022] Open
Abstract
The objective of this study was to estimate the risk of developing second malignancies to partially in‐field organs from volumetric modulated arc therapy (VMAT) of cervical cancer and to compare the above risks with those from the conventional three‐dimensional conformal radiotherapy (3D‐CRT). Seventeen consecutive patients with uterine cervix carcinoma were selected. VMAT and 3D‐CRT plans were generated with 6 and 10 MV photons, respectively. The prescribed tumor dose was 45 Gy given in 25 fractions. Differential dose‐volume histogram data from the treatment plans were obtained for the partially in‐field organs such as bladder and rectum. These data were used to estimate the patient‐specific lifetime attributable risk (LAR) for bladder and rectal cancer induction with a non‐linear model based on a mixture of plateau and bell‐shaped dose–response relationships. The estimated risks per 10000 people were compared with the baseline risks for unexposed population. The patient‐specific rectal cancer risk estimates from VMAT were significantly lower than those from 3D‐CRT (P = 0.0144). The LARs for developing bladder malignancies from VMAT were significantly high compared to those from conventional irradiation (P = 0.0003). The mean difference between the patient‐specific LARs for radiation‐induced bladder and rectal malignancies as derived from 3D‐CRT and VMAT plans was 6.6% and 2.0%, respectively. The average LAR for developing bladder and rectal malignant diseases due to VMAT was 9.2 × 10‐4 and 43.7 × 10‐4, respectively. The corresponding risks following 3D‐CRT were 8.6 × 10‐4 and 44.6 × 10‐4. These average risks showed that pelvic irradiation increases the baseline probability for cancer induction by 12.6‐19.1%. The differences in the second cancer risks associated with the VMAT and 3D‐CRT for cervical cancer were found to be small. Both treatment techniques resulted in considerable increased probabilities for developing bladder and rectal malignancies relative to those of unirradiated population.
Collapse
Affiliation(s)
- Michalis Mazonakis
- Department of Medical Physics, Faculty of Medicine, University of Crete, Crete, Greece
| | - Efrosyni Lyraraki
- Department of Radiotherapy and Oncology, University Hospital of Iraklion, Iraklion, Crete, Greece
| | - Maria Tolia
- Department of Radiotherapy and Oncology, University Hospital of Iraklion, Iraklion, Crete, Greece
| | - John Damilakis
- Department of Medical Physics, Faculty of Medicine, University of Crete, Crete, Greece
| |
Collapse
|
11
|
Colnot J, Zefkili S, Gschwind R, Huet C. Out-of-field doses from radiotherapy using photon beams: A comparative study for a pediatric renal treatment. J Appl Clin Med Phys 2021; 22:94-106. [PMID: 33547766 PMCID: PMC7984471 DOI: 10.1002/acm2.13182] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Revised: 12/20/2020] [Accepted: 01/06/2021] [Indexed: 12/04/2022] Open
Abstract
PURPOSE First, this experimental study aims at comparing out-of-field doses delivered by three radiotherapy techniques (3DCRT, VMAT (two different accelerators), and tomotherapy) for a pediatric renal treatment. Secondly, the accuracy of treatment planning systems (TPS) for out-of-field calculation is evaluated. METHODS EBT3 films were positioned in pediatric phantoms (5 and 10 yr old). They were irradiated according to four plans: 3DCRT (Clinac 2100CS, Varian), VMAT (Clinac 2100CS and Halcyon, Varian), and tomotherapy for a same target volume. 3D dose determination was performed with an in-house Matlab tool using linear interpolation of film measurements. 1D and 3D comparisons were made between techniques. Finally, measurements were compared to the Eclipse (Varian) and Tomotherapy (Accuray) TPS calculations. RESULTS Advanced radiotherapy techniques (VMATs and tomotherapy) deliver higher out-of-field doses compared to 3DCRT due to increased beam-on time triggered by intensity modulation. Differences increase with distance to target and reach a factor of 3 between VMAT and 3DCRT. Besides, tomotherapy delivers lower doses than VMAT: although tomotherapy beam-on time is higher than in VMAT, the additional shielding of the Hi-Art system reduces out-of-field doses. The latest generation Halcyon system proves to deliver lower peripheral doses than conventional accelerators. Regarding TPS calculation, tomotherapy proves to be suitable for out-of-field dose determination up to 30 cm from field edge whereas Eclipse (AAA and AXB) largely underestimates those doses. CONCLUSION This study shows that the high dose conformation allowed by advanced radiotherapy is done at the cost of higher peripheral doses. In the context of treatment-related risk estimation, the consequence of this increase might be significative. Modern systems require adapted head shielding and a particular attention has to be taken regarding on-board imaging dose. Finally, TPS advanced dose calculation algorithms do not certify dose accuracy beyond field edges, and thus, those doses are not suitable for risk assessment.
Collapse
Affiliation(s)
- Julie Colnot
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Service de Recherche en Dosimétrie, Laboratoire de Dosimétrie des Rayonnements Ionisants, Fontenay-aux-Roses, France
| | - Sofia Zefkili
- Institut Curie, Service de Physique Médicale, Paris, France
| | - Régine Gschwind
- Université de Bourgogne-Franche-Comté, LCE UMR 6249, Montbéliard, France
| | - Christelle Huet
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Service de Recherche en Dosimétrie, Laboratoire de Dosimétrie des Rayonnements Ionisants, Fontenay-aux-Roses, France
| |
Collapse
|
12
|
García-Hernández T, Romero-Expósito M, Sánchez-Nieto B. Low dose radiation therapy for COVID-19: Effective dose and estimation of cancer risk. Radiother Oncol 2020; 153:289-295. [PMID: 33065184 PMCID: PMC7553901 DOI: 10.1016/j.radonc.2020.09.051] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2020] [Revised: 09/16/2020] [Accepted: 09/27/2020] [Indexed: 01/11/2023]
Abstract
BACKGROUND AND PURPOSE The objective of this work is to evaluate the risk of carcinogenesis of low dose ionizing radiation therapy (LDRT), for treatment of immune-related pneumonia following COVID-19 infection, through the estimation of effective dose and the lifetime attributable risk of cancer (LAR). MATERIAL AND METHODS LDRT treatment was planned in male and female computational phantoms. Equivalent doses in organs were estimated using both treatment planning system calculations and a peripheral dose model (based on ionization chamber measurements). Skin dose was estimated using radiochromic films. Later, effective dose and LAR were calculated following radiation protection procedures. RESULTS Equivalent doses to organs per unit of prescription dose range from 10 mSv/cGy to 0.0051 mSv/cGy. Effective doses range from 204 mSv to 426 mSv, for prescription doses ranging from 50 cGy to 100 cGy. Total LAR for a prescription dose of 50 cGy ranges from 1.7 to 0.29% for male and from 4.9 to 0.54% for female, for ages ranging from 20 to 80 years old. CONCLUSIONS The organs that mainly contribute to risk are lung and breast. Risk for out-of-field organs is low, less than 0.06 cases per 10000. Female LAR is on average 2.2 times that of a male of the same age. Effective doses are of the same order of magnitude as the higher-dose interventional radiology techniques. For a 60 year-old male, LAR is 8 times that from a cardiac CT, when prescription dose is 50 cGy.
Collapse
Affiliation(s)
| | - Maite Romero-Expósito
- Área de Ciencias Básicas y Ambientales, Instituto Tecnológico de Santo Domingo (INTEC), P.O. Box 342-9/249-2, Santo Domingo, Dominican Republic
| | | |
Collapse
|
13
|
Delana A, Barbareschi A, Consorti R, Daniela Falco M. Dose calculation accuracy in proximity of a pacemaker: A multicenter study with threecommercial treatment planning systems. Phys Med 2020; 80:201-208. [DOI: 10.1016/j.ejmp.2020.10.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 10/02/2020] [Accepted: 10/22/2020] [Indexed: 11/16/2022] Open
|
14
|
Faghihi Moghaddam F, Bakhshandeh M, Ghorbani M, Mofid B. Assessing the out-of-field dose calculation accuracy by eclipse treatment planning system in sliding window IMRT of prostate cancer patients. Comput Biol Med 2020; 127:104052. [PMID: 33126124 DOI: 10.1016/j.compbiomed.2020.104052] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 10/07/2020] [Accepted: 10/09/2020] [Indexed: 11/18/2022]
Abstract
AIM The objective of this study was to evaluate out-of-field dose distribution calculation accuracy by the Anisotropic Analytical Algorithm (AAA), version 13.0.26, in Eclipse TPS, (Varian Medical Systems, Palo Alto, Ca, USA) for sliding window IMRT delivery technique in prostate cancer patients. MATERIALS AND METHODS Prostate IMRT plans with nine coplanar were calculated with the AAA Eclipse treatment planning system. To assess the accuracy of dose calculation predicted by the Eclipse in normal tissue and OARs located out of radiation field areas, including the rectum, bladder, right and left head of the femur, absolute organ dose value, and dose distribution were measured using the Delta4+ IMRT phantom. RESULTS In the out-of-field areas, underestimation of -0.66% in organs near the field edge to -39.63% in organs far from the field edge (2.5 and 7.3 cm respectively) occurred in the TPS calculations. The percentage of dose deviation for the femoral heads was 95.7 on average while for the organ closer to the target (rectum) it was 79.81. CONCLUSIONS AAA dosimetry algorithm (used in Eclipse TPS) showed poor dose calculation in areas beyond the treatment fields border where underestimation varies with the distance from the field edges. A significant underestimation was found for the AAA algorithm in the sliding window IMRT technique (P-value > 0.05).
Collapse
Affiliation(s)
- Fahimeh Faghihi Moghaddam
- Biomedical Engineering and Medical Physics Department, Faculty of Medical Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| | - Mohsen Bakhshandeh
- Department of Radiation Technology, Faculty of Allied Medical Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| | - Mahdi Ghorbani
- Department of Medical Physics, Faculty of Medical Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| | - Bahram Mofid
- Department of Radiation Oncology, Faculty of Medical Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
15
|
Irazola L, Sánchez-Nieto B, García-Hernández MT, Terrón JA, Roselló J, Ortiz-Seidel M, Béjar MJ, Linares R, Vélazquez S, Sánchez-Doblado F. 10-MV SBRT FFF IRRADIATION TECHNIQUE IS ASSOCIATED TO THE LOWEST PERIPHERAL DOSE: THE OUTCOME OF 142 TREATMENT PLANS FOR THE 10 MOST COMMON TUMOUR LOCATIONS. RADIATION PROTECTION DOSIMETRY 2019; 185:183-195. [PMID: 30649534 DOI: 10.1093/rpd/ncy292] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Revised: 12/06/2018] [Accepted: 12/30/2018] [Indexed: 06/09/2023]
Abstract
There is a growing interest in the combined use of Stereotactic Body Radiation Therapy (SBRT) with Flattening Filter Free (FFF) due to the high local control rates and reduced treatment times, compared to conventionally fractionated treatments. It has been suggested that they may also provide a better radiation protection to radiotherapy patients as a consequence of the expected decrease in peripheral doses. This work aims to determine this reduction in unattended out-of-field regions, where no CT information is available but an important percentage of second primary cancers occur. For that purpose, ten different cases suitable for SBRT were chosen. Thus, 142 different treatment plans including SBRT, as well as 3D-CRT, IMRT and VMAT (with standard fractionation) in low and high energies for Varian (FF and FFF), Siemens and Elekta machines were created. Then, photon and neutron peripheral dose in 14 organs were assessed and compared using two analytical models. For the prostate case, uncomplicated and cancer free control probability estimation was also carried out. As a general behavior, SBRT plans led to the lowest peripheral doses followed by 3D-CRT, VMAT and IMRT, in this order. Unflattened beams proved to be the most effective in reducing peripheral doses, especially for 10 MV. The obtained results suggest that FFF beams for SBRT with 10 MV represent the best compromise between dose delivery efficiency and peripheral dose reduction.
Collapse
Affiliation(s)
- L Irazola
- Departamento de Fisiología Médica y Biofísica, Facultad de Medicina, Universidad de Sevilla, Sevilla, Spain
- Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla, Spain
| | - B Sánchez-Nieto
- Instituto de Física, Pontificia Universidad Católica de Chile, Santiago, Chile
| | | | - J A Terrón
- Departamento de Fisiología Médica y Biofísica, Facultad de Medicina, Universidad de Sevilla, Sevilla, Spain
- Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla, Spain
| | - J Roselló
- Servicio de Radiofísica ERESA, Hospital General Universitario, Valencia, Spain
| | - M Ortiz-Seidel
- Departamento de Fisiología Médica y Biofísica, Facultad de Medicina, Universidad de Sevilla, Sevilla, Spain
- Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla, Spain
| | - M J Béjar
- Servicio de Radiofísica, Hospital Universitario Ramón y Cajal, Madrid, Spain
| | - R Linares
- Servicio de Radiofísica, Hospital Infanta Luisa, Sevilla, Spain
| | - S Vélazquez
- Servicio de Radiofísica, Hospital Universitario Virgen del Rocío, Sevilla Spain
| | - F Sánchez-Doblado
- Departamento de Fisiología Médica y Biofísica, Facultad de Medicina, Universidad de Sevilla, Sevilla, Spain
- Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla, Spain
| |
Collapse
|
16
|
Ghareeb F, Lencart J, Oliveira J, Santos JAM. Characterization of Extrafocal Dose Influence on the Out-of-Field Dose Distribution by Monte Carlo Simulations and Dose Measurements. HEALTH PHYSICS 2019; 117:489-503. [PMID: 31033708 DOI: 10.1097/hp.0000000000001079] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Out-of-field scattered and transmitted extrafocal radiation may induce secondary cancer in long-term survivors of external radiotherapy. Pediatric patients have higher life expectancy and tend to receive higher secondary radiation damage due to geometric and biological factors. The goal of this study is to characterize the location and the magnitude of extrafocal dose regions in the case of three-dimensional conformal radiotherapy and volumetric arc therapy, to apply this information to clinical treatment cases, and to provide mitigation strategies. Extrafocal dose has been investigated in a Varian TrueBeam linac equipped with a high-definition 120 multileaf collimator using different physical and virtual phantoms, dose calculation (including Monte Carlo techniques), and dose measurement methods. All Monte Carlo calculations showed excellent agreement with measurements. Treatment planning system calculations failed to provide reliable results out of the treatment field. Both Monte Carlo calculations and dose measurements showed regions with higher dose (extrafocal dose areas) when compared to the background. These areas start to be noticeable beyond 11 cm from the isocenter in the direction perpendicular to the multileaf collimator leaves' travel direction. Out-of-field extrafocal doses up to 160% of the mean dose transmitted through the closed multileaf collimator were registered. Two overlapping components were observed in the extrafocal distribution: the first is an almost elliptical blurred dose distribution, and the second is a well-defined rectangular dose distribution. Extra precautions should be taken into consideration when treating pediatric patients with a high-definition 120 multileaf collimator to avoid directing the extrafocal radiation into a radiosensitive organ during external beam therapy.
Collapse
Affiliation(s)
- Firass Ghareeb
- Medical Physics, Radiobiology and Radiation Protection Group, IPO Porto Research Center (CI-IPOP), Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal
| | - Joana Lencart
- Medical Physics, Radiobiology and Radiation Protection Group, IPO Porto Research Center (CI-IPOP), Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal
- Medical Physics Department, Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal
| | - Jorge Oliveira
- Medical Physics, Radiobiology and Radiation Protection Group, IPO Porto Research Center (CI-IPOP), Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal
| | - João A M Santos
- Medical Physics, Radiobiology and Radiation Protection Group, IPO Porto Research Center (CI-IPOP), Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal
- Medical Physics Department, Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal
- Instituto de Ciências Biomédicas Abel Salazar (ICBAS), University of Porto, Porto, Portugal
| |
Collapse
|
17
|
Colnot J, Barraux V, Loiseau C, Berejny P, Batalla A, Gschwind R, Huet C. A new Monte Carlo model of a Cyberknife ® system for the precise determination of out-of-field doses. Phys Med Biol 2019; 64:195008. [PMID: 31387085 DOI: 10.1088/1361-6560/ab38e5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In a previous work, a PENELOPE Monte Carlo model of a Cyberknife system equipped with fixed collimator was developed and validated for in-field dose evaluation. The aim of this work is to extend it to evaluate peripheral doses and to determine the precision of the treatment planning system (TPS) Multiplan in evaluating the off-axis doses. The Cyberknife® head model was completed with surrounding components based on manufacturer drawings. The contribution of the different head parts on the out-of-field dose was studied. To model the attenuation and the modification of particle energy caused by components not modelled, the photon transport was modified in one of the added components. The model was iteratively adjusted to fit dose profiles measured with EBT3 films and an ionization chamber for several collimator sizes. Finally, dose profiles were calculated using the two Multiplan TPS algorithms and were compared to our simulations. The contributions to out-of-field dose were identified as scattered radiation from the phantom and head leakage and scatter originating at the secondary collimator level. Particle transport in the additional pieces was modified to model this radiation. The maximum differences between simulated and measured doses are of 20.4%. Regarding the detector responses away from axis, EBT3 films and the Farmer chamber give similar response (less than 20% difference). The TPS Monte Carlo algorithm underestimates the doses away from axis more importantly for the smaller field sizes (up to 98%). Besides, RayTracing simplifies peripheral dose to a constant value with no inclusion of particle transport. A Monte Carlo model of a Cyberknife system for the determination of out-of-field doses up to 14 cm off-axis was successfully developed and validated for different depths and field sizes in comparison with measurements. This study also confirms that TPS algorithms do not model peripheral dose properly.
Collapse
Affiliation(s)
- J Colnot
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Service de Recherche en Dosimétrie, Laboratoire de Dosimétrie des Rayonnements Ionisants, Fontenay-aux-Roses, France. Author to whom correspondence should be addressed
| | | | | | | | | | | | | |
Collapse
|
18
|
Farhood B, Ghorbani M. Dose Calculation Accuracy of Radiotherapy Treatment Planning Systems in Out-of-Field Regions. J Biomed Phys Eng 2019; 9:133-136. [PMID: 31214518 PMCID: PMC6538908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2018] [Accepted: 03/28/2018] [Indexed: 12/02/2022]
Affiliation(s)
- B. Farhood
- Department of Medical Physics and Radiology, Faculty of Paramedical Sciences, Kashan University of Medical Sciences, Kashan, Iran
| | - M. Ghorbani
- Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
19
|
Momeni Z, Tavakoli MB, Atarod M. Estimation of the Thyroid Secondary Cancer Risk on the Patient of Standard Breast External Beam Radiotherapy. JOURNAL OF MEDICAL SIGNALS & SENSORS 2019; 8:238-243. [PMID: 30603616 PMCID: PMC6293648 DOI: 10.4103/jmss.jmss_12_18] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
Background: The purpose of this study was to estimate the secondary cancer risk of thyroid in standard radiotherapy methods which are commonly used for breast cancer patients. Methods: A total of 64 breast cancer patients (their age range was around 50 years old) who referred to Seyed-Al-Shohada hospital (Isfahan, Iran) were included in this study. The radiotherapy of the mentioned patients was performed using 6-MV photon beams. Dose measurements were also done using thermoluminescent dosimeters. Calculation of the risk of developing secondary cancer in thyroid was done using the Biological Effects of Ionizing Radiation Committee VII and recommended quantity of the International Radiation Protection Commission, excess relative risk. Results: The mean radiation dose to thyroid for the tangential beams, tangential field with supraclavicular (SC) field, and also a tangential field with SC field in modified radical mastectomy (MRM) were 0.883 ± 0.472, 1.512 ± 0.365, and 1.587 ± 0.37, respectively. The risk of developing secondary thyroid cancer over a period of 5 years after breast cancer therapy in the tangential, tangential with a SC field, and also tangential beam with SC field in MRM were 9.974 ± 4.318, 17.891 ± 0.365, and 18.783 ± 4.384, respectively. The mean of the measured thyroid doses in patients treated with tangent fields was significantly lower than the patients under the irradiation of the tangent fields with SC field (P < 0.001). Conclusions: Using radiation protection equipment is suggested for breast cancer patients who treated with the studied radiotherapy methods.
Collapse
Affiliation(s)
- Zeinab Momeni
- Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Mohammad Bagher Tavakoli
- Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Maryam Atarod
- Department of Medical Physics, School of Medicine, Shahrekord University of Medical Sciences, Shahrekord, Iran
| |
Collapse
|
20
|
Craft DF, Balter P, Woodward W, Kry SF, Salehpour M, Ger R, Peters M, Baltz G, Traneus E, Howell RM. Design, fabrication, and validation of patient-specific electron tissue compensators for postmastectomy radiation therapy. Phys Imaging Radiat Oncol 2018; 8:38-43. [PMID: 33458415 PMCID: PMC7807570 DOI: 10.1016/j.phro.2018.11.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Revised: 11/09/2018] [Accepted: 11/13/2018] [Indexed: 11/17/2022] Open
Abstract
Background and purpose Postmastectomy radiotherapy (PMRT) is complex to plan and deliver, but could be improved with 3D-printed, patient-specific electron tissue compensators. The purposes of this study were to develop an algorithm to design patient-specific compensators that achieve clinical goals, to 3D-print the planned compensators, and validate calculated dose distributions with film and thermoluminescent dosimeter (TLD) measurements in 3D-printed phantoms of PMRT patients. Materials and methods An iterative algorithm was developed to design compensators corresponding to single-field, single-energy electron plans for PMRT patients. The 3D-printable compensators were designed to fit into the electron aperture, with cerrobend poured around it. For a sample of eight patients, calculated dose distributions for compensator plans were compared with patients’ (multi-field, multi-energy) clinical treatment plans. For all patients, dosimetric parameters were compared including clinical target volume (CTV), lung, and heart metrics. For validation, compensators were fabricated and irradiated for a set of six 3D-printed patient-specific phantoms. Dose distributions in the phantoms were measured with TLD and film. These measurements were compared with the treatment planning system calculated dose distributions. Results The compensator treatment plans achieved superior CTV coverage (97% vs 89% of the CTV receiving the prescription dose, p < 0.0025), and similar heart and lung doses (p > 0.35) to the conventional treatment plans. Average differences between calculated and measured TLD values were 2%, and average film profile differences were <2 mm. Conclusions We developed a new compensator based treatment methodology for PMRT and demonstrated its validity and superiority to conventional multi-field plans through end-to-end testing.
Collapse
Affiliation(s)
- Daniel F. Craft
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
- The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX 77030, USA
- Corresponding author at: Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Unit 94, Houston, TX 77030, USA.
| | - Peter Balter
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
- The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX 77030, USA
| | - Wendy Woodward
- The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX 77030, USA
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Stephen F. Kry
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
- The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX 77030, USA
| | - Mohammad Salehpour
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
- The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX 77030, USA
| | - Rachel Ger
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
- The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX 77030, USA
| | - Mary Peters
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
- The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX 77030, USA
| | - Garrett Baltz
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
- The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX 77030, USA
| | - Erik Traneus
- RaySearch Laboratories AB, Stockholm 111 34, Sweden
| | - Rebecca M. Howell
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
- The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX 77030, USA
| |
Collapse
|
21
|
Alvarez Moret J, Obermeier T, Pohl F, Loeschel R, Koelbl O, Dobler B. Second cancer risk after radiation therapy of ependymoma using the flattening filter free irradiation mode of a linear accelerator. J Appl Clin Med Phys 2018; 19:632-639. [PMID: 30125453 PMCID: PMC6123158 DOI: 10.1002/acm2.12438] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2018] [Revised: 06/06/2018] [Accepted: 07/16/2018] [Indexed: 12/05/2022] Open
Abstract
Pediatric patients suffering from ependymoma are usually treated with cranial or craniospinal three‐dimensional (3D) conformal radiotherapy (3DCRT). Intensity‐modulated techniques spare dose to the surrounding tissue, but the risk for second malignancies may be increased due to the increase in low‐dose volume. The aim of this study is to investigate if the flattening filter free (FFF) mode allows reducing the risk for second malignancies compared to the mode with flattening filter (FF) for intensity‐modulated techniques and to 3DCRT. A reduction of the risk would be advantageous for treating pediatric ependymoma. 3DCRT was compared to intensity‐modulated radiation therapy (IMRT) and volumetric‐modulated arc therapy (VMAT) with and without flattening filter. Dose–volume histograms (DVHs) were compared to evaluate the plan quality and used to calculate the excess absolute risk (EAR) to develop second cancer in the brain. Dose verification was performed with a two‐dimensional (2D) ionization chamber array and the out‐of‐field dose was measured with an ionization chamber to determine the EAR in peripheral organs. Delivery times were measured. Both VMAT and IMRT achieved similar plan quality in terms of dose sparing in the OAR and higher PTV coverage as compared to 3DCRT. Peripheral dose in low‐dose region, which is proportional to the EAR in organs located in this region, for example, gonads, bladder, or bowel, could be significantly reduced using FFF. The lowest peripheral EAR and lowest delivery times were hereby achieved with VMATFFF. The EAR calculated based on DVH in the brain could not be reduced using FFF mode. VMATFFF improved the target coverage and homogeneity and kept the dose in the OAR similar compared to 3DCRT. In addition, delivery times were significantly reduced using VMATFFF. Therefore, for radiotherapy of ependymoma patients, VMATFFF may be considered advantageous for the combination of Elekta Synergy linac and Oncentra External Beam planning system used in this study.
Collapse
Affiliation(s)
- Judit Alvarez Moret
- Department of Radiotherapy, Regensburg University Medical Center, Regensburg, Germany
| | - Tina Obermeier
- Department of Radiotherapy, Regensburg University Medical Center, Regensburg, Germany
| | - Fabian Pohl
- Department of Radiotherapy, Regensburg University Medical Center, Regensburg, Germany
| | - Rainer Loeschel
- Department of Computer Science and Mathematics, University of Applied Sciences, OTH Regensburg, Regensburg, Germany
| | - Oliver Koelbl
- Department of Radiotherapy, Regensburg University Medical Center, Regensburg, Germany
| | - Barbara Dobler
- Department of Radiotherapy, Regensburg University Medical Center, Regensburg, Germany
| |
Collapse
|
22
|
Sánchez-Nieto B, Romero-Expósito M, Terrón JA, Irazola L, Paiusco M, Cagni E, Ghetti C, Filice S, Sánchez-Doblado F. Intensity-modulated radiation therapy and volumetric modulated arc therapy versus conventional conformal techniques at high energy: Dose assessment and impact on second primary cancer in the out-of-field region. Rep Pract Oncol Radiother 2018; 23:251-259. [PMID: 29991929 PMCID: PMC6035902 DOI: 10.1016/j.rpor.2018.04.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2017] [Revised: 01/19/2018] [Accepted: 04/12/2018] [Indexed: 12/22/2022] Open
Abstract
The aim of this work was to estimate peripheral neutron and photon doses associated with the conventional 3D conformal radiotherapy techniques in comparison to modern ones such as Intensity modulated radiation therapy and volumetric modulated arc therapy. Assessment in terms of second cancer incidence ought to peripheral doses was also considered. For that, a dosimetric methodology proposed by the authors has been applied beyond the region where there is no CT information and, thus, treatment planning systems do not calculate and where, nonetheless, about one third of second primary cancers occurs.
Collapse
Affiliation(s)
- Beatriz Sánchez-Nieto
- Instituto de Física, Pontificia Universidad Católica de Chile, Santiago, Chile
- Center UC Investigation in Oncology at Pontificia Universidad Católica de Chile, Pontificia Universidad Católica de Chile, Santiago, Chile
| | | | - José Antonio Terrón
- Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla, Spain
| | - Leticia Irazola
- Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Sevilla, Spain
| | - Marta Paiusco
- Veneto Institute of Oncology IOV – IRCCS, Padua, Italy
| | | | - Caterina Ghetti
- Servizio di Fisica Sanitaria, Azienda Ospedaliera Universitaria di Parma, Italy
| | - Silvano Filice
- Servizio di Fisica Sanitaria, Azienda Ospedaliera Universitaria di Parma, Italy
| | - Francisco Sánchez-Doblado
- Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla, Spain
- Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Sevilla, Spain
| |
Collapse
|
23
|
Mille MM, Jung JW, Lee C, Kuzmin GA, Lee C. Comparison of normal tissue dose calculation methods for epidemiological studies of radiotherapy patients. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2018; 38:775-792. [PMID: 29637904 PMCID: PMC6007019 DOI: 10.1088/1361-6498/aabd4f] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Radiation dosimetry is an essential input for epidemiological studies of radiotherapy patients aimed at quantifying the dose-response relationship of late-term morbidity and mortality. Individualised organ dose must be estimated for all tissues of interest located in-field, near-field, or out-of-field. Whereas conventional measurement approaches are limited to points in water or anthropomorphic phantoms, computational approaches using patient images or human phantoms offer greater flexibility and can provide more detailed three-dimensional dose information. In the current study, we systematically compared four different dose calculation algorithms so that dosimetrists and epidemiologists can better understand the advantages and limitations of the various approaches at their disposal. The four dose calculations algorithms considered were as follows: the (1) Analytical Anisotropic Algorithm (AAA) and (2) Acuros XB algorithm (Acuros XB), as implemented in the Eclipse treatment planning system (TPS); (3) a Monte Carlo radiation transport code, EGSnrc; and (4) an accelerated Monte Carlo code, the x-ray Voxel Monte Carlo (XVMC). The four algorithms were compared in terms of their accuracy and appropriateness in the context of dose reconstruction for epidemiological investigations. Accuracy in peripheral dose was evaluated first by benchmarking the calculated dose profiles against measurements in a homogeneous water phantom. Additional simulations in a heterogeneous cylinder phantom evaluated the performance of the algorithms in the presence of tissue heterogeneity. In general, we found that the algorithms contained within the commercial TPS (AAA and Acuros XB) were fast and accurate in-field or near-field, but not acceptable out-of-field. Therefore, the TPS is best suited for epidemiological studies involving large cohorts and where the organs of interest are located in-field or partially in-field. The EGSnrc and XVMC codes showed excellent agreement with measurements both in-field and out-of-field. The EGSnrc code was the most accurate dosimetry approach, but was too slow to be used for large-scale epidemiological cohorts. The XVMC code showed similar accuracy to EGSnrc, but was significantly faster, and thus epidemiological applications seem feasible, especially when the organs of interest reside far away from the field edge.
Collapse
Affiliation(s)
- Matthew M Mille
- Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD 20850, United States of America
| | | | | | | | | |
Collapse
|
24
|
Xie L, Lin C, Zhang H, Bao X. Second malignancy in young early-stage breast cancer patients with modern radiotherapy: A long-term population-based study (A STROBE-compliant study). Medicine (Baltimore) 2018; 97:e0593. [PMID: 29703057 PMCID: PMC5944535 DOI: 10.1097/md.0000000000010593] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Second cancer is a leading cause of death in long-term survivors of younger early-stage breast cancer patients. To date, relationship of age, receipt of radiotherapy (RT), and estimated doses received by target organs have not yet been well elucidated. Using Surveillance, Epidemiology, and End Results database, patients aged 20 to 44, diagnosed with a first primary staging I-IIIA ipsilateral breast invasive ductal carcinoma, underwent surgery during 1988 to 2009 were identified, and those with a second malignancy at ≥1-year follow-up were analyzed to calculate cumulative incidences (CIs) of second malignancy in whole group and each subgroup. Subgroups were dichotomized by surgery type, axillary dissection, and axillary lymph node status. With a median follow-up of 11.8 years, 22,628 women including 1495 patients (6.6%) developing second malignancies (3.7% contralateral breast cancer, 2.9% non-breast second malignancies, and 0.7% high-dose site second malignancies) were identified. Three-dimensional coordinate systems with age at primary diagnosis, time after primary breast cancer diagnosis, and CI of second malignancy as 3 axes, for endpoints including all second malignancy, second primary contralateral breast cancer, and non-breast second malignancy were presented, along with the risk in RT and non-RT groups in overall group and subgroups. Five-, 10-, 15-, and 20-year all second malignancy-free survivals in RT and non-RT groups were 89.5% versus 85.4%, 80.1% versus 75.0%, 72.9% versus 67.9%, and 65.6% versus 61.8% (P < .0001). From the large national dataset, a broad visualized overview of second malignancy risk, including second contralateral breast cancer and non-breast second cancer, suggests generally beneficial therapeutic ratio for radiotherapy in young women with early-stage breast cancer.
Collapse
Affiliation(s)
- Liyi Xie
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center
- Department of Oncology, Shanghai Medical College, Fudan University, Shanghai
| | - Chen Lin
- Department of Medical Oncology, Zhejiang Cancer Hospital, Hangzhou, Zhejiang
| | - Huan Zhang
- Department of Internal Medicine, Shanghai Changhai Hospital, Shanghai, China
| | - Xuhui Bao
- Department of Surgery, Duke University Medical Center, Durham, NC, USA
| |
Collapse
|
25
|
Taddei PJ, Khater N, Youssef B, Howell RM, Jalbout W, Zhang R, Geara FB, Giebeler A, Mahajan A, Mirkovic D, Newhauser WD. Low- and middle-income countries can reduce risks of subsequent neoplasms by referring pediatric craniospinal cases to centralized proton treatment centers. Biomed Phys Eng Express 2018; 4:025029. [PMID: 30038799 PMCID: PMC6054490 DOI: 10.1088/2057-1976/aaa1ce] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Few children with cancer in low- and middle-income countries (LMICs) have access to proton therapy. Evidence exists to support replacing photon therapy with proton therapy to reduce the incidence of secondary malignant neoplasms (SMNs) in childhood cancer survivors. The purpose of this study was to estimate the potential reduction in SMN incidence and in SMN mortality for pediatric medulloblastoma patients in LMICs if proton therapy were made available to them. For nine children of ages 2 to 14 years, we calculated the equivalent dose in organs or tissues at risk for radiogenic SMNs from therapeutic and stray radiation for photon craniospinal irradiation (CSI) in a LMIC and proton CSI in a high-income country. We projected the lifetime risks of SMN incidence and SMN mortality for every SMN site with a widely-used model from the literature. We found that the average total lifetime attributable risks of incidence and mortality were very high for both photon CSI (168% and 41%, respectively) and proton CSI (88% and 26%, respectively). SMNs having the highest risk of mortality were lung cancer (16%), non-site-specific solid tumors (16%), colon cancer (5.9%), leukemia (5.4%), and for girls breast cancer (5.0%) after photon CSI and non-site-specific solid tumors (12%), lung cancer (11%), and leukemia (4.8%) after proton CSI. The risks were higher for younger children than for older children and higher for girls than for boys. The ratios of proton CSI to photon CSI of total risks of SMN incidence and mortality were 0.56 (95% CI, 0.37 to 0.75) and 0.64 (95% CI, 0.45 to 0.82), respectively, averaged over this sample group. In conclusion, proton therapy has the potential to lessen markedly subsequent SMNs and SMN fatalities in survivors of childhood medulloblastoma in LMICs, for example, through regional centralized care. Additional methods should be explored urgently to reduce therapeutic-field doses in organs and tissues at risk for SMN, especially in the lungs, colon, and breast tissues.
Collapse
Affiliation(s)
- Phillip J Taddei
- Department of Radiation Oncology, Faculty of Medicine, American University of Beirut Medical Center, P.O. Box 11-0236, Riad El-Solh, Beirut, 1107 2020, Lebanon
- Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, 77030, USA
- Department of Radiation Oncology, University of Washington School of Medicine, Seattle, WA, 98195, USA
| | - Nabil Khater
- Department of Radiation Oncology, Hôtel-Dieu de France Hospital, University of St. Joseph, P.O. Box 166830, Alfred Naccache Blvd, Beirut, Lebanon
| | - Bassem Youssef
- Department of Radiation Oncology, Faculty of Medicine, American University of Beirut Medical Center, P.O. Box 11-0236, Riad El-Solh, Beirut, 1107 2020, Lebanon
| | - Rebecca M Howell
- Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - Wassim Jalbout
- Department of Radiation Oncology, Faculty of Medicine, American University of Beirut Medical Center, P.O. Box 11-0236, Riad El-Solh, Beirut, 1107 2020, Lebanon
| | - Rui Zhang
- Medical Physics Program, Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA, 70803, USA
- Department of Physics, Mary Bird Perkins Cancer Center, Baton Rouge, LA, 70809, USA
| | - Fady B. Geara
- Department of Radiation Oncology, Faculty of Medicine, American University of Beirut Medical Center, P.O. Box 11-0236, Riad El-Solh, Beirut, 1107 2020, Lebanon
| | - Annelise Giebeler
- Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - Anita Mahajan
- Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - Dragan Mirkovic
- Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - Wayne D Newhauser
- Medical Physics Program, Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA, 70803, USA
- Department of Physics, Mary Bird Perkins Cancer Center, Baton Rouge, LA, 70809, USA
| |
Collapse
|
26
|
Lee HF, Lan JH, Chao PJ, Ting HM, Chen HC, Hsu HC, Lee TF. Radiation-induced secondary malignancies for nasopharyngeal carcinoma: a pilot study of patients treated via IMRT or VMAT. Cancer Manag Res 2018; 10:131-141. [PMID: 29403311 PMCID: PMC5783017 DOI: 10.2147/cmar.s145713] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Background Patients treated with radiotherapy are at risk of developing a second cancer during their lifetime, which can directly impact treatment decision-making and patient management. The aim of this study was to qualify and compare the secondary cancer risk (SCR) after intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in nasopharyngeal carcinoma (NPC) patients. Patients and methods We analyzed the treatment plans of a cohort of 10 NPC patients originally treated with IMRT or VMAT. Dose distributions in these plans were used to calculate the organ equivalent dose (OED) with Schneider’s full model. Analyses were applied to the brain stem, spinal cord, oral cavity, pharynx, parotid glands, lung, mandible, healthy tissue, and planning target volume. Results We observed that the OED-based risks of SCR were slightly higher for the oral cavity and mandible when VMAT was used. No significant difference was found in terms of the doses to other organs, including the brain stem, parotids, pharynx, submandibular gland, lung, spinal cord, and healthy tissue. In the NPC cohort, the lungs were the organs that were most sensitive to radiation-induced cancer. Conclusion VMAT afforded superior results in terms of organ-at-risk-sparing compared with IMRT. Most OED-based second cancer risks for various organs were similar when VMAT and IMRT were employed, but the risks for the oral cavity and mandible were slightly higher when VMAT was used.
Collapse
Affiliation(s)
- Hsiao-Fei Lee
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung, Taiwan, Republic of China.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, Republic of China
| | - Jen-Hong Lan
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung, Taiwan, Republic of China.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, Republic of China
| | - Pei-Ju Chao
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung, Taiwan, Republic of China.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, Republic of China
| | - Hui-Min Ting
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung, Taiwan, Republic of China.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, Republic of China
| | - Hui-Chun Chen
- Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, Republic of China
| | - Hsuan-Chih Hsu
- Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, Republic of China
| | - Tsair-Fwu Lee
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung, Taiwan, Republic of China.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, Republic of China.,Graduate Institute of Clinical Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan, Republic of China.,Department of Radiation Oncology, Kaohsiung Yuan's General Hospital, Kaohsiung, Taiwan, Republic of China
| |
Collapse
|
27
|
Yoon J, Heins D, Zhao X, Sanders M, Zhang R. Measurement and modeling of out-of-field doses from various advanced post-mastectomy radiotherapy techniques. Phys Med Biol 2017; 62:9039-9053. [PMID: 29048329 DOI: 10.1088/1361-6560/aa94b5] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
More and more advanced radiotherapy techniques have been adopted for post-mastectomy radiotherapies (PMRT). Patient dose reconstruction is challenging for these advanced techniques because they increase the low out-of-field dose area while the accuracy of out-of-field dose calculations by current commercial treatment planning systems (TPSs) is poor. We aim to measure and model the out-of-field radiation doses from various advanced PMRT techniques. PMRT treatment plans for an anthropomorphic phantom were generated, including volumetric modulated arc therapy with standard and flattening-filter-free photon beams, mixed beam therapy, 4-field intensity modulated radiation therapy (IMRT), and tomotherapy. We measured doses in the phantom where the TPS calculated doses were lower than 5% of the prescription dose using thermoluminescent dosimeters (TLD). The TLD measurements were corrected by two additional energy correction factors, namely out-of-beam out-of-field (OBOF) correction factor K OBOF and in-beam out-of-field (IBOF) correction factor K IBOF, which were determined by separate measurements using an ion chamber and TLD. A simple analytical model was developed to predict out-of-field dose as a function of distance from the field edge for each PMRT technique. The root mean square discrepancies between measured and calculated out-of-field doses were within 0.66 cGy Gy-1 for all techniques. The IBOF doses were highly scattered and should be evaluated case by case. One can easily combine the measured out-of-field dose here with the in-field dose calculated by the local TPS to reconstruct organ doses for a specific PMRT patient if the same treatment apparatus and technique were used.
Collapse
Affiliation(s)
- Jihyung Yoon
- Medical Physics Program, Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA, United States of America
| | | | | | | | | |
Collapse
|
28
|
Kry SF, Bednarz B, Howell RM, Dauer L, Followill D, Klein E, Paganetti H, Wang B, Wuu CS, George Xu X. AAPM TG 158: Measurement and calculation of doses outside the treated volume from external-beam radiation therapy. Med Phys 2017; 44:e391-e429. [DOI: 10.1002/mp.12462] [Citation(s) in RCA: 164] [Impact Index Per Article: 20.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2016] [Revised: 05/17/2017] [Accepted: 05/25/2017] [Indexed: 12/14/2022] Open
Affiliation(s)
- Stephen F. Kry
- Department of Radiation Physics; MD Anderson Cancer Center; Houston TX 77054 USA
| | - Bryan Bednarz
- Department of Medical Physics; University of Wisconsin; Madison WI 53705 USA
| | - Rebecca M. Howell
- Department of Radiation Physics; MD Anderson Cancer Center; Houston TX 77054 USA
| | - Larry Dauer
- Departments of Medical Physics/Radiology; Memorial Sloan-Kettering Cancer Center; New York NY 10065 USA
| | - David Followill
- Department of Radiation Physics; MD Anderson Cancer Center; Houston TX 77054 USA
| | - Eric Klein
- Department of Radiation Oncology; Washington University; Saint Louis MO 63110 USA
| | - Harald Paganetti
- Department of Radiation Oncology; Massachusetts General Hospital and Harvard Medical School; Boston MA 02114 USA
| | - Brian Wang
- Department of Radiation Oncology; University of Louisville; Louisville KY 40202 USA
| | - Cheng-Shie Wuu
- Department of Radiation Oncology; Columbia University; New York NY 10032 USA
| | - X. George Xu
- Department of Mechanical, Aerospace, and Nuclear Engineering; Rensselaer Polytechnic Institute; Troy NY 12180 USA
| |
Collapse
|
29
|
Out-of-field in vivo dosimetry using TLD in SABR for primary kidney cancer involving mixed photon fields. Phys Med 2017; 37:9-15. [PMID: 28535921 DOI: 10.1016/j.ejmp.2017.03.022] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/01/2016] [Revised: 03/21/2017] [Accepted: 03/27/2017] [Indexed: 11/20/2022] Open
Abstract
PURPOSE To assess out-of-field dose using three different variants of LiF thermoluminescence dosimeters (TLD) for ten patients who underwent stereotactic ablative body radiotherapy (SABR) for primary renal cell carcinoma (RCC) and compare with treatment planning system (TPS) dose calculations. METHODS AND MATERIALS Thermoluminescent dosimeter (TLD) measurements were conducted at 20, 30, 40 and 50cm from isocentre on ten patients undergoing SABR for primary RCC. Three types of high-sensitivity LiF:Mg,Cu,P TLD material with different 6Li/7Li isotope ratios were used. Patient plans were calculated using Eclipse Anisotropic Analytical Algorithm (AAA) for clinical evaluation and recalculated using Pencil Beam Convolution (PBC) algorithm for comparison. RESULTS Both AAA and PBC showed diminished accuracy for photon doses at increasing distance out-of-field. At 50cm, measured photon dose was 0.3cGy normalised to a 10Gy prescription on average with only small variation across all patients. This is likely due to the leakage component of the out-of-field dose. The 6Li-enriched TLD materials showed increased signal attributable to additional neutron contribution. CONCLUSION LiF:Mg,Cu,P TLD containing 6Li is sensitive enough to measure out-of-field dose 50cm from isocentre however will over-estimate the photon component of out-of-field dose in high energy treatments due to the presence of thermal neutrons. 7Li enriched materials which are insensitive to neutrons are therefore required for accurate photon dosimetry. Neutron signal has been shown here to increase with MUs and is higher for patients treated using certain non coplanar beam arrangements. Further work is required to convert this additional neutron signal to dose.
Collapse
|
30
|
Harrison R. Out-of-field doses in radiotherapy: Input to epidemiological studies and dose-risk models. Phys Med 2017; 42:239-246. [PMID: 28392312 DOI: 10.1016/j.ejmp.2017.02.001] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2016] [Revised: 01/19/2017] [Accepted: 02/03/2017] [Indexed: 01/18/2023] Open
Abstract
Out-of-field doses in radiotherapy have been increasingly studied in recent years because of the generally improved survival of patients who have received radiotherapy as part of their treatment for cancer and their subsequent risk of a second malignancy. This short article attempts to identify some current problems, challenges and opportunities for dosimetry developments in this field. Out-of-field doses and derived risk estimates contribute to general knowledge about radiation effects on humans as well as contributing to risk-benefit considerations for the individual patient. It is suggested that for input into epidemiological studies, the complete dose description (i.e. the synthesis of therapy and imaging doses from all the treatment and imaging modalities) is ideally required, although there is currently no common dosimetry framework which easily covers all modalities. A general strategy for out-of-field dose estimation requires development and improvement in several areas including (i) dosimetry in regions of steep dose gradient close to the field edge (ii) experimentally verified analytical and Monte Carlo models for out-of-field doses (iii) the validity of treatment planning system algorithms outside the field edge (iv) dosimetry of critical sub-structures in organs at risk (v) mixed field (including neutron) dosimetry in proton and ion radiotherapy and photoneutron production in high energy photon beams (vi) the most appropriate quantities to use in neutron dosimetry in a radiotherapy context and (vii) simplification of measurement methods in regions distant from the target volume.
Collapse
Affiliation(s)
- Roger Harrison
- Institute of Cellular Medicine, Faculty of Medical Sciences, University of Newcastle upon Tyne, UK.
| |
Collapse
|
31
|
Sánchez-Nieto B, Romero-Expósito M, Terrón JA, Sánchez-Doblado F. Uncomplicated and Cancer-Free Control Probability (UCFCP): A new integral approach to treatment plan optimization in photon radiation therapy. Phys Med 2017; 42:277-284. [PMID: 28392313 DOI: 10.1016/j.ejmp.2017.03.025] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2016] [Revised: 03/24/2017] [Accepted: 03/29/2017] [Indexed: 12/25/2022] Open
Abstract
PURPOSE Biological treatment plan evaluation does not currently consider second cancer induction from peripheral doses associated to photon radiotherapy. The aim is to propose a methodology to characterize the therapeutic window by means of an integral radiobiological approach, which considers not only Tumour Control Probability (TCP) and Normal Tissue Complication Probability (NTCP) but also Secondary Cancer Probability (SCP). METHODS Uncomplicated and Cancer-Free Control Probability (UCFCP) function has been proposed assuming a statistically uncorrelated response for tumour and normal tissues. The Poisson's and Lyman's models were chosen for TCP and NTCP calculations, respectively. SCP was modelled as the summation of risks associated to photon and neutron irradiation of radiosensitive organs. For the medium (>4Gy) and low dose regions, mechanistic and linear secondary cancer risks models were used, respectively. Two conformal and intensity-modulated prostate plans at 15MV (same prescription dose) were selected to illustrate the UCFCP features. RESULTS UCFCP exhibits a bell-shaped behaviour with its maximum inside the therapeutic window. SCP values were not different for the plans analysed (∼2.4%) and agreed with published epidemiological results. Therefore, main differences in UCFCP came from differences in rectal NTCP (18% vs 9% for 3D-CRT and IMRT, respectively). According to UCFCP values, the evaluated IMRT plan ranked first. CONCLUSIONS The level of SCP was found to be similar to that of NTCP complications which reinforces the importance of considering second cancer risks as part of the possible late sequelae due to treatment. Previous concerns about the effect of peripheral radiation, especially neutrons, in the induction of secondary cancers can be evaluated by quantifying the UCFCP.
Collapse
Affiliation(s)
- Beatriz Sánchez-Nieto
- Instituto de Física, Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna 4880, Macul, Santiago, Chile.
| | - Maite Romero-Expósito
- Departament de Física, Universitat Autònoma de Barcelona, Edifici C, Campus UAB E-08193, Bellaterra, Spain.
| | - José A Terrón
- Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Av. Doctor Fedriani, 3, 41009 Sevilla, Spain.
| | - Francisco Sánchez-Doblado
- Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Av. Doctor Fedriani, 3, 41009 Sevilla, Spain; Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Av. Doctor Fedriani S/N, 41009 Sevilla, Spain.
| |
Collapse
|
32
|
Vũ Bezin J, Allodji RS, Mège JP, Beldjoudi G, Saunier F, Chavaudra J, Deutsch E, de Vathaire F, Bernier V, Carrie C, Lefkopoulos D, Diallo I. A review of uncertainties in radiotherapy dose reconstruction and their impacts on dose-response relationships. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2017; 37:R1-R18. [PMID: 28118156 DOI: 10.1088/1361-6498/aa575d] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Proper understanding of the risk of radiation-induced late effects for patients receiving external photon beam radiotherapy requires the determination of reliable dose-response relationships. Although significant efforts have been devoted to improving dose estimates for the study of late effects, the most often questioned explanatory variable is still the dose. In this work, based on a literature review, we provide an in-depth description of the radiotherapy dose reconstruction process for the study of late effects. In particular, we focus on the identification of the main sources of dose uncertainty involved in this process and summarise their impacts on the dose-response relationship for radiotherapy late effects. We provide a number of recommendations for making progress in estimating the uncertainties in current studies of radiotherapy late effects and reducing these uncertainties in future studies.
Collapse
Affiliation(s)
- Jérémi Vũ Bezin
- Inserm, Radiation Epidemiology Team, CESP-U1018, F-94807, Villejuif, France. Gustave Roussy, Villejuif, F-94805, France. Paris-Sud University, Orsay, F-91400, France
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
33
|
Han EY, Paudel N, Sung J, Yoon M, Chung WK, Kim DW. Estimation of the risk of secondary malignancy arising from whole-breast irradiation: comparison of five radiotherapy modalities, including TomoHDA. Oncotarget 2016; 7:22960-9. [PMID: 27027239 PMCID: PMC5008415 DOI: 10.18632/oncotarget.8392] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2015] [Accepted: 03/18/2016] [Indexed: 12/25/2022] Open
Abstract
The risk of secondary cancer from radiation treatment remains a concern for long-term breast cancer survivors, especially those treated with radiation at the age younger than 45 years. Treatment modalities optimally maximize the dose delivery to the tumor while minimizing radiation doses to neighboring organs, which can lead to secondary cancers. A new TomoTherapy treatment machine, TomoHDATM, can treat an entire breast with two static but intensity-modulated beams in a slice-by-slice fashion. This feature could reduce scattered and leakage radiation doses. We compared the plan quality and lifetime attributable risk (LAR) of a second malignancy among five treatment modalities: three-dimensional conformal radiation therapy, field-in-field forward-planned intensity-modulated radiation therapy, inverse-planned intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy, and TomoDirect mode on the TomoHDA system. Ten breast cancer patients were selected for retrospective analysis. Organ equivalent doses, plan characteristics, and LARs were compared. Out-of-field organ doses were measured with radio-photoluminescence glass dosimeters. Although the IMRT plan provided overall better plan quality, including the lowest probability of pneumonitis, it caused the second highest LAR. The TomoTherapy plan provided plan quality comparable to the IMRT plan and posed the lowest total LAR to neighboring organs. Therefore, it can be a better treatment modality for younger patients who have a longer life expectancy.
Collapse
Affiliation(s)
- Eun Young Han
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Nava Paudel
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Jiwon Sung
- Department of Bio-Convergence Engineering, Korea University, Seoul, Korea
| | - Myonggeun Yoon
- Department of Bio-Convergence Engineering, Korea University, Seoul, Korea
| | - Weon Kuu Chung
- Department of Radiation Oncology, Kyung Hee University Hospital at Gangdong, Seoul, Korea
| | - Dong Wook Kim
- Department of Radiation Oncology, Kyung Hee University Hospital at Gangdong, Seoul, Korea
| |
Collapse
|
34
|
Homann K, Howell R, Eley J. The need for individualized studies to compare radiogenic second cancer (RSC) risk in proton versus photon Hodgkin Lymphoma patient treatments. ACTA ACUST UNITED AC 2016. [DOI: 10.14319/jpt.11.8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
35
|
Rühm W, Fantuzzi E, Harrison R, Schuhmacher H, Vanhavere F, Alves J, Bottollier Depois JF, Fattibene P, Knežević Ž, Lopez MA, Mayer S, Miljanić S, Neumaier S, Olko P, Stadtmann H, Tanner R, Woda C. EURADOS strategic research agenda: vision for dosimetry of ionising radiation. RADIATION PROTECTION DOSIMETRY 2016; 168:223-34. [PMID: 25752758 PMCID: PMC4884873 DOI: 10.1093/rpd/ncv018] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2014] [Revised: 02/05/2015] [Accepted: 02/06/2015] [Indexed: 05/04/2023]
Abstract
Since autumn 2012, the European Radiation Dosimetry Group (EURADOS) has been developing its Strategic Research Agenda (SRA), which is intended to contribute to the identification of future research needs in radiation dosimetry in Europe. The present article summarises-based on input from EURADOS Working Groups (WGs) and Voting Members-five visions in dosimetry and defines key issues in dosimetry research that are considered important for the next decades. The five visions include scientific developments required towards (a) updated fundamental dose concepts and quantities, (b) improved radiation risk estimates deduced from epidemiological cohorts, (c) efficient dose assessment for radiological emergencies, (d) integrated personalised dosimetry in medical applications and (e) improved radiation protection of workers and the public. The SRA of EURADOS will be used as a guideline for future activities of the EURADOS WGs. A detailed version of the SRA can be downloaded as a EURADOS report from the EURADOS website (www.eurados.org).
Collapse
Affiliation(s)
- W Rühm
- Helmholtz Center Munich, Institute of Radiation Protection, Neuherberg, Germany
| | - E Fantuzzi
- Radiation Protection Institute, ENEA, Bologna, Italy
| | | | - H Schuhmacher
- Physikalisch Technische Bundesanstalt (PTB), Braunschweig, Germany
| | - F Vanhavere
- Belgian Nuclear Research Centre (SCK-CEN), Mol, Belgium
| | - J Alves
- Instituto Superior Técnico (IST), CTN, Lisboa, Portugal
| | - J F Bottollier Depois
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Fontenay-aux-Roses Cedex, France
| | - P Fattibene
- Istituto Superiore di Sanità (ISS), Rome, Italy
| | - Ž Knežević
- Ruđer Bošković Institute (RBI), Zagreb, Croatia
| | - M A Lopez
- Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT), Madrid, Spain
| | - S Mayer
- Paul Scherer Institut (PSI), Villigen, Switzerland
| | - S Miljanić
- Ruđer Bošković Institute (RBI), Zagreb, Croatia
| | - S Neumaier
- Physikalisch Technische Bundesanstalt (PTB), Braunschweig, Germany
| | - P Olko
- Instytut Fizyki Jądrowej (IFJ), Krakow, Poland
| | - H Stadtmann
- Seibersdorf Labor GmbH, Seibersdorf, Austria
| | - R Tanner
- Public Health England, Chilton, Didcot, UK
| | - C Woda
- Helmholtz Center Munich, Institute of Radiation Protection, Neuherberg, Germany
| |
Collapse
|
36
|
Sánchez-Nieto B, El-far R, Irazola L, Romero-Expósito M, Lagares JI, Mateo JC, Terrón JA, Doblado FS. Analytical model for photon peripheral dose estimation in radiotherapy treatments. Biomed Phys Eng Express 2015. [DOI: 10.1088/2057-1976/1/4/045205] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
37
|
Toltz A, Shin N, Mitrou E, Laude C, Freeman CR, Seuntjens J, Parker W, Roberge D. Late radiation toxicity in Hodgkin lymphoma patients: proton therapy's potential. J Appl Clin Med Phys 2015; 16:167–178. [PMID: 26699298 PMCID: PMC5690189 DOI: 10.1120/jacmp.v16i5.5386] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2014] [Revised: 05/20/2015] [Accepted: 05/03/2015] [Indexed: 12/22/2022] Open
Abstract
In 2010, all young patients treated for intrathoracic Hodgkin lymphoma (HL) at one of 10 radiotherapy centers in the province of Quebec received 3D conformal photon therapy. These patients may now be at risk for late effects of their treatment, notably secondary malignancies and cardiac toxicity. We hypothesized that more complex radiotherapy, including intensity‐modulated proton therapy (IMPT) and possibly IMRT (in the form of helical tomotherapy (HT)), could benefit these patients. With institutional review board approval at 10 institutions, all treatment plans for patients under the age of 30 treated for HL during a six‐month consecutive period of 2010 were retrieved. Twenty‐six patients were identified, and after excluding patients with extrathoracic radiation or treatment of recurrence, 20 patients were replanned for HT and IMPT. Neutron dose for IMPT plans was estimated from published measurements. The relative seriality model was used to predict excess risk of cardiac mortality. A modified linear quadratic model was used to predict the excess absolute risk for induction of lung cancer and, in female patients, breast cancer. Model parameters were derived from published data. Predicted risk for cardiac mortality was similar among the three treatment techniques (absolute excess risk of cardiac mortality was not reduced for HT or IMPT (p>0.05,p>0.05) as compared to 3D CRT). Predicted risks were increased for HT and reduced for IMPT for secondary lung cancer (p<0.001,p<0.001) and breast cancers (p<0.001,p<0.001) as compared to 3D CRT. PACS numbers: 87.55.dh, 87.55.dk
Collapse
|
38
|
Weltman E, Marta GN, Baraldi HS, Pimentel L, Castilho M, Maia MAC, Lundgren MSFS, Chen MJ, Novaes PERS, Gadia R, Ferrigno R, Motta R, Hanna SA, Almeida W. Treatment of abdominal tumors using radiotherapy. Rev Assoc Med Bras (1992) 2015; 61:108-13. [DOI: 10.1590/1806-9282.61.02.108] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
|
39
|
Inter-Institutional Comparison of Personalized Risk Assessments for Second Malignant Neoplasms for a 13-Year-Old Girl Receiving Proton versus Photon Craniospinal Irradiation. Cancers (Basel) 2015; 7:407-26. [PMID: 25763928 PMCID: PMC4381265 DOI: 10.3390/cancers7010407] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2014] [Revised: 02/18/2015] [Accepted: 02/19/2015] [Indexed: 01/14/2023] Open
Abstract
Children receiving radiotherapy face the probability of a subsequent malignant neoplasm (SMN). In some cases, the predicted SMN risk can be reduced by proton therapy. The purpose of this study was to apply the most comprehensive dose assessment methods to estimate the reduction in SMN risk after proton therapy vs. photon therapy for a 13-year-old girl requiring craniospinal irradiation (CSI). We reconstructed the equivalent dose throughout the patient’s body from therapeutic and stray radiation and applied SMN incidence and mortality risk models for each modality. Excluding skin cancer, the risk of incidence after proton CSI was a third of that of photon CSI. The predicted absolute SMN risks were high. For photon CSI, the SMN incidence rates greater than 10% were for thyroid, non-melanoma skin, lung, colon, stomach, and other solid cancers, and for proton CSI they were non-melanoma skin, lung, and other solid cancers. In each setting, lung cancer accounted for half the risk of mortality. In conclusion, the predicted SMN risk for a 13-year-old girl undergoing proton CSI was reduced vs. photon CSI. This study demonstrates the feasibility of inter-institutional whole-body dose and risk assessments and also serves as a model for including risk estimation in personalized cancer care.
Collapse
|
40
|
Comprehensive craniospinal radiation for controlling central nervous system leukemia. Int J Radiat Oncol Biol Phys 2015; 90:1119-25. [PMID: 25539370 DOI: 10.1016/j.ijrobp.2014.08.004] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2014] [Revised: 07/18/2014] [Accepted: 08/02/2014] [Indexed: 11/24/2022]
Abstract
PURPOSE To determine the benefit of radiation therapy (RT) in resolution of neurologic symptoms and deficits and whether the type of RT fields influences central nervous system (CNS) control in adults with CNS leukemia. METHODS AND MATERIALS A total of 163 adults from 1996 to 2012 were retrospectively analyzed. Potential associations between use of radiation and outcome were investigated by univariate and multivariate analysis. RESULTS The median survival time was 3.8 months after RT. Common presenting symptoms were headache in 79 patients (49%), cranial nerve VII deficit in 46 (28%), and cranial nerve II deficit in 44 (27%). RT was delivered to the base of skull in 48 patients (29%), to the whole brain (WB) in 67 (41%), and to the craniospinal axis (CS) in 48 (29%). Among 149 patients with a total of 233 deficits, resolution was observed in 34 deficits (15%), improvement in 126 deficits (54%), stability in 34 deficits (15%), and progression in 39 deficits (17%). The 12-month CNS progression-free survival was 77% among those receiving CS/WB and 51% among those receiving base of skull RT (P=.02). On multivariate analysis, patients who did not undergo stem cell transplantation after RT and base of skull RT were associated with worse CNS progression-free survival. CONCLUSIONS Improvement or resolution of symptoms occurred in two thirds of deficits after RT. Comprehensive radiation to the WB or CS seems to offer a better outcome, especially in isolated CNS involvement.
Collapse
|
41
|
Zhang R, Howell RM, Taddei PJ, Giebeler A, Mahajan A, Newhauser WD. A comparative study on the risks of radiogenic second cancers and cardiac mortality in a set of pediatric medulloblastoma patients treated with photon or proton craniospinal irradiation. Radiother Oncol 2014; 113:84-8. [PMID: 25128084 PMCID: PMC4256116 DOI: 10.1016/j.radonc.2014.07.003] [Citation(s) in RCA: 66] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2013] [Revised: 07/09/2014] [Accepted: 07/10/2014] [Indexed: 12/30/2022]
Abstract
PURPOSE To compare the risks of radiogenic second cancers and cardiac mortality in 17 pediatric medulloblastoma patients treated with passively scattered proton or field-in-field photon craniospinal irradiation (CSI). MATERIAL/METHODS Standard of care photon or proton CSI treatment plans were created for all 17 patients in a commercial treatment planning system (TPS) (Eclipse version 8.9; Varian Medical Systems, Palo Alto, CA) and prescription dose was 23.4 or 23.4 Gy (RBE) to the age specific target volume at 1.8 Gy/fraction. The therapeutic doses from proton and photon CSI plans were estimated from TPS. Stray radiation doses were determined from Monte Carlo simulations for proton CSI and from measurements and TPS for photon CSI. The Biological Effects of Ionization Radiation VII report and a linear model based on childhood cancer survivor data were used for risk predictions of second cancer and cardiac mortality, respectively. RESULTS The ratios of lifetime attributable risk (RLARs) (proton/photon) ranged from 0.10 to 0.22 for second cancer incidence and ranged from 0.20 to 0.53 for second cancer mortality, respectively. The ratio of relative risk (RRR) (proton/photon) of cardiac mortality ranged from 0.12 to 0.24. The RLARs of both cancer incidence and mortality decreased with patient's age at exposure (e), while the RRRs of cardiac mortality increased with e. Girls had a significantly higher RLAR of cancer mortality than boys. CONCLUSION Passively scattered proton CSI provides superior predicted outcomes by conferring lower predicted risks of second cancer and cardiac mortality than field-in-field photon CSI for all medulloblastoma patients in a large clinically representative sample in the United States, but the magnitude of superiority depends strongly on the patients' anatomical development status.
Collapse
Affiliation(s)
- Rui Zhang
- The University of Texas Graduate School of Biomedical Sciences at Houston, USA; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, USA
| | - Rebecca M Howell
- The University of Texas Graduate School of Biomedical Sciences at Houston, USA; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, USA
| | - Phillip J Taddei
- The University of Texas Graduate School of Biomedical Sciences at Houston, USA; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, USA; Department of Radiation Oncology, American University of Beirut Medical Center, Lebanon
| | - Annelise Giebeler
- The University of Texas Graduate School of Biomedical Sciences at Houston, USA; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, USA; Current address is: Scripps Proton Therapy Center, San Diego, CA, USA
| | - Anita Mahajan
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, USA
| | - Wayne D Newhauser
- The University of Texas Graduate School of Biomedical Sciences at Houston, USA; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, USA; Medical Physics Program, Department of Physics and Astronomy, Louisiana State University, Baton Rouge, USA.
| |
Collapse
|
42
|
Wang L, Ding GX. The accuracy of the out-of-field dose calculations using a model based algorithm in a commercial treatment planning system. Phys Med Biol 2014; 59:N113-28. [PMID: 24925858 DOI: 10.1088/0031-9155/59/13/n113] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The out-of-field dose can be clinically important as it relates to the dose of the organ-at-risk, although the accuracy of its calculation in commercial radiotherapy treatment planning systems (TPSs) receives less attention. This study evaluates the uncertainties of out-of-field dose calculated with a model based dose calculation algorithm, anisotropic analytical algorithm (AAA), implemented in a commercial radiotherapy TPS, Varian Eclipse V10, by using Monte Carlo (MC) simulations, in which the entire accelerator head is modeled including the multi-leaf collimators. The MC calculated out-of-field doses were validated by experimental measurements. The dose calculations were performed in a water phantom as well as CT based patient geometries and both static and highly modulated intensity-modulated radiation therapy (IMRT) fields were evaluated. We compared the calculated out-of-field doses, defined as lower than 5% of the prescription dose, in four H&N cancer patients and two lung cancer patients treated with volumetric modulated arc therapy (VMAT) and IMRT techniques. The results show that the discrepancy of calculated out-of-field dose profiles between AAA and the MC depends on the depth and is generally less than 1% for in water phantom comparisons and in CT based patient dose calculations for static field and IMRT. In cases of VMAT plans, the difference between AAA and MC is <0.5%. The clinical impact resulting from the error on the calculated organ doses were analyzed by using dose-volume histograms. Although the AAA algorithm significantly underestimated the out-of-field doses, the clinical impact on the calculated organ doses in out-of-field regions may not be significant in practice due to very low out-of-field doses relative to the target dose.
Collapse
Affiliation(s)
- Lilie Wang
- Department of Radiation Oncology, Stanford University, CA, USA
| | | |
Collapse
|
43
|
Kim DW, Chung K, Chung WK, Bae SH, Shin DO, Hong S, Park SH, Park SY, Hong CS, Lim YK, Shin D, Lee SB, Lee HH, Sung J, Yoon M. Risk of secondary cancers from scattered radiation during intensity-modulated radiotherapies for hepatocellular carcinoma. Radiat Oncol 2014; 9:109. [PMID: 24886163 PMCID: PMC4030012 DOI: 10.1186/1748-717x-9-109] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2013] [Accepted: 03/17/2014] [Indexed: 12/25/2022] Open
Abstract
PURPOSE To evaluate and compare the risks of secondary cancers from therapeutic doses received by patients with hepatocellular carcinoma (HCC) during intensity-modulated radiotherapy (IMRT), volumetric arc therapy (VMAT), and tomotherapy (TOMO). METHODS Treatments for five patients with hepatocellular carcinoma (HCC) were planned using IMRT, VMAT, and TOMO. Based on the Biological Effects of Ionizing Radiation VII method, the excess relative risk (ERR), excess absolute risk (EAR), and lifetime attributable risk (LAR) were evaluated from therapeutic doses, which were measured using radiophotoluminescence glass dosimeters (RPLGDs) for each organ inside a humanoid phantom. RESULTS The average organ equivalent doses (OEDs) of 5 patients were measured as 0.23, 1.18, 0.91, 0.95, 0.97, 0.24, and 0.20 Gy for the thyroid, lung, stomach, liver, small intestine, prostate (or ovary), and rectum, respectively. From the OED measurements, LAR incidence were calculated as 83, 46, 22, 30, 2 and 6 per 10(4) person for the lung, stomach, normal liver, small intestine, prostate (or ovary), and rectum. CONCLUSIONS We estimated the secondary cancer risks at various organs for patients with HCC who received different treatment modalities. We found that HCC treatment is associated with a high secondary cancer risk in the lung and stomach.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | | | | | | | | | - Myonggeun Yoon
- Department of Radiological Science, College of Health Science, Korea University, Jeongneung 3-dong, Seongbuk-gu, Seoul, Korea.
| |
Collapse
|
44
|
Tessa CL, Berger T, Kaderka R, Schardt D, Burmeister S, Labrenz J, Reitz G, Durante M. Characterization of the secondary neutron field produced during treatment of an anthropomorphic phantom with x-rays, protons and carbon ions. Phys Med Biol 2014; 59:2111-25. [DOI: 10.1088/0031-9155/59/8/2111] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
45
|
|
46
|
Harrison R. Introduction to dosimetry and risk estimation of second cancer induction following radiotherapy. RADIAT MEAS 2013. [DOI: 10.1016/j.radmeas.2013.01.018] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
47
|
Photon dosimetry methods outside the target volume in radiation therapy: Optically stimulated luminescence (OSL), thermoluminescence (TL) and radiophotoluminescence (RPL) dosimetry. RADIAT MEAS 2013. [DOI: 10.1016/j.radmeas.2013.03.004] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
48
|
In regard to: Letter to the Editor "the impact of early life exposure to diagnostic and therapeutic radiation on childhood cancer risk". Phys Med 2013 29, 221-223. Phys Med 2013; 30:1. [PMID: 24055408 DOI: 10.1016/j.ejmp.2013.08.141] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2013] [Revised: 08/22/2013] [Accepted: 08/26/2013] [Indexed: 11/20/2022] Open
|
49
|
Zhang R, Howell RM, Homann K, Giebeler A, Taddei PJ, Mahajan A, Newhauser WD. Predicted risks of radiogenic cardiac toxicity in two pediatric patients undergoing photon or proton radiotherapy. Radiat Oncol 2013; 8:184. [PMID: 23880421 PMCID: PMC3751146 DOI: 10.1186/1748-717x-8-184] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2013] [Accepted: 07/21/2013] [Indexed: 01/12/2023] Open
Abstract
Background Hodgkin disease (HD) and medulloblastoma (MB) are common malignancies found in children and young adults, and radiotherapy is part of the standard treatment. It was reported that these patients who received radiation therapy have an increased risk of cardiovascular late effects. We compared the predicted risk of developing radiogenic cardiac toxicity after photon versus proton radiotherapies for a pediatric patient with HD and a pediatric patient with MB. Methods In the treatment plans, each patient’s heart was contoured in fine detail, including substructures of the pericardium and myocardium. Risk calculations took into account both therapeutic and stray radiation doses. We calculated the relative risk (RR) of cardiac toxicity using a linear risk model and the normal tissue complication probability (NTCP) values using relative seriality and Lyman models. Uncertainty analyses were also performed. Results The RR values of cardiac toxicity for the HD patient were 7.27 (proton) and 8.37 (photon), respectively; the RR values for the MB patient were 1.28 (proton) and 8.39 (photon), respectively. The predicted NTCP values for the HD patient were 2.17% (proton) and 2.67% (photon) for the myocardium, and were 2.11% (proton) and 1.92% (photon) for the whole heart. The predicted ratios of NTCP values (proton/photon) for the MB patient were much less than unity. Uncertainty analyses revealed that the predicted ratio of risk between proton and photon therapies was sensitive to uncertainties in the NTCP model parameters and the mean radiation weighting factor for neutrons, but was not sensitive to heart structure contours. The qualitative findings of the study were not sensitive to uncertainties in these factors. Conclusions We conclude that proton and photon radiotherapies confer similar predicted risks of cardiac toxicity for the HD patient in this study, and that proton therapy reduced the predicted risk for the MB patient in this study.
Collapse
Affiliation(s)
- Rui Zhang
- The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX, USA.
| | | | | | | | | | | | | |
Collapse
|
50
|
Zhang R, Howell RM, Giebeler A, Taddei PJ, Mahajan A, Newhauser WD. Comparison of risk of radiogenic second cancer following photon and proton craniospinal irradiation for a pediatric medulloblastoma patient. Phys Med Biol 2013; 58:807-23. [PMID: 23322160 PMCID: PMC3615542 DOI: 10.1088/0031-9155/58/4/807] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Pediatric patients who received radiation therapy are at risk of developing side effects such as radiogenic second cancer. We compared proton and photon therapies in terms of the predicted risk of second cancers for a 4 year old medulloblastoma patient receiving craniospinal irradiation (CSI). Two CSI treatment plans with 23.4 Gy or Gy (RBE) prescribed dose were computed: a three-field 6 MV photon therapy plan and a four-field proton therapy plan. The primary doses for both plans were determined using a commercial treatment planning system. Stray radiation doses for proton therapy were determined from Monte Carlo simulations, and stray radiation doses for photon therapy were determined from measured data. Dose-risk models based on the Biological Effects of Ionization Radiation VII report were used to estimate the risk of second cancer in eight tissues/organs. Baseline predictions of the relative risk for each organ were always less for proton CSI than for photon CSI at all attained ages. The total lifetime attributable risk of the incidence of second cancer considered after proton CSI was much lower than that after photon CSI, and the ratio of lifetime risk was 0.18. Uncertainty analysis revealed that the qualitative findings of this study were insensitive to any plausible changes of dose-risk models and mean radiation weighting factor for neutrons. Proton therapy confers lower predicted risk of second cancer than photon therapy for the pediatric medulloblastoma patient.
Collapse
Affiliation(s)
- Rui Zhang
- Graduate School of Biomedical Sciences, The University of Texas at Houston, Houston, TX, USA
- Department of Radiation Physics and Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Rebecca M Howell
- Graduate School of Biomedical Sciences, The University of Texas at Houston, Houston, TX, USA
- Department of Radiation Physics and Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Annelise Giebeler
- Graduate School of Biomedical Sciences, The University of Texas at Houston, Houston, TX, USA
- Department of Radiation Physics and Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Phillip J Taddei
- Graduate School of Biomedical Sciences, The University of Texas at Houston, Houston, TX, USA
- Department of Radiation Physics and Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
- Department of Radiation Oncology, Faculty of Medicine, American University of Beirut, Beirut, Lebanon
| | - Anita Mahajan
- Department of Radiation Physics and Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Wayne D Newhauser
- Graduate School of Biomedical Sciences, The University of Texas at Houston, Houston, TX, USA
- Department of Radiation Physics and Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
- Louisiana State University, Medical Physics Program, Department of Physics and Astronomy, Baton Rouge, LA, USA
- Mary Bird Perkins Cancer Center, Baton Rouge, LA, USA
| |
Collapse
|