1
|
Diao Y, Liu L, Deng N, Lyu S, Hirata A. Tensor-conductance model for reducing the computational artifact in target tissue for low-frequency dosimetry. Phys Med Biol 2023; 68:205014. [PMID: 37722382 DOI: 10.1088/1361-6560/acfae0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Accepted: 09/18/2023] [Indexed: 09/20/2023]
Abstract
Objective.In protecting human from low-frequency (<100 kHz) exposure, an induced electric field strength is used as a physical quantity for assessment. However, the computational assessment suffers from a staircasing error because of the approximation of curved boundary discretized with cubic voxels. The international guidelines consider an additional reduction factor of 3 when setting the limit of external field strength computed from the permissible induced electric field. Here, a new method was proposed to reduce the staircasing error considering the tensor conductance in human modeling for low-frequency dosimetry.Approach.We proposed a tensor-based conductance model, which was developed on the basis of the filling ratio and the direction of the tissue interface to satisfy the electric field boundary condition and reduce staircasing errors in the target tissue of a voxel human model.Main results.The proposed model was validated using two-layer nonconcentric cylindrical and spherical models with different conductivity contrasts. A comparison of induced electric field strengths with solutions obtained using an analytical formula and finite element method simulation indicated that for a wide range of conductivity ratios, staircasing errors were reduced compared with a conventional scalar-potential finite-difference method. The induced electric field in a simple anatomical head model using our approach was in good agreement with finite element method for exposure to uniform magnetic field exposure and that from coil, simulating transcranial magnetic stimulation.Significance.The proposed tensor-conductance model demonstrated that the staircasing error in an inner target tissue of a voxel human body can be reduced. This finding can be used for the electromagnetic compliance assessment and dose evaluation in electric or magnetic stimulation at low frequencies.
Collapse
Affiliation(s)
- Yinliang Diao
- College of Electronic Engineering, College of Artificial Intelligence, South China Agricultural University, Guangzhou 510642, People's Republic of China
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya 466-8555, Japan
| | - Li Liu
- College of Electronic Engineering, College of Artificial Intelligence, South China Agricultural University, Guangzhou 510642, People's Republic of China
| | - Nuo Deng
- College of Electronic Engineering, College of Artificial Intelligence, South China Agricultural University, Guangzhou 510642, People's Republic of China
| | - Shilei Lyu
- College of Electronic Engineering, College of Artificial Intelligence, South China Agricultural University, Guangzhou 510642, People's Republic of China
| | - Akimasa Hirata
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya 466-8555, Japan
- Center of Biomedical Physics and Information Technology, Nagoya Institute of Technology, Nagoya 466-8555, Japan
| |
Collapse
|
2
|
Yamaguchi-Sekino S, Taki M, Ikuyo M, Esaki K, Aimoto A, Wake K, Kojimahara N. Assessment of combined exposure to intermediate-frequency electromagnetic fields and pulsed electromagnetic fields among library workers in Japan. Front Public Health 2022; 10:870784. [PMID: 35968480 PMCID: PMC9366663 DOI: 10.3389/fpubh.2022.870784] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Accepted: 07/05/2022] [Indexed: 11/13/2022] Open
Abstract
Objective To assess exposure levels to electromagnetic fields (EMFs) among library workers in Japan, focusing on co-exposure to intermediate-frequency EMF (IF-EMF) and pulsed EMF, to propose a new epidemiological research methodology. Methods The evaluated exposure sources were an electromagnetic type-electronic article surveillance gate (EM-EAS, IF-EMF (operating frequency 220 Hz-14 kHz)) and an activator/deactivator of anti-theft tags termed as “book check unit” (BCU, pulsed EMF). Short-term exposures were: (E1) whole-body exposure from the EAS gate when sitting within 3 m; (E2) local exposure to transient IF-EMF while passing through or beside the EAS gate; and (E3) local exposure to a pulsed magnetic field on BCU use. E1–E3 were evaluated based on exposure levels relative to magnetic flux density at the occupational reference level (RL; E1) or as per occupational basic restrictions (BR; E2 and E3) delineated by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) 2010 guidelines. Exposure indices based on mid-term exposure (D1–D3), assuming exposure according to employment on a weekly basis, were used to assess exposure in actual working conditions. D1 represents continuous exposure from an EAS gate when sitting within 3 m of the gate. D2 and D3 represent repeated transient exposures occurring during gate pass or on the operation of a BCU. A link to a web-based questionnaire was distributed to librarians working at all libraries where the authors had mailed institutional questionnaires (4,073 libraries). Four exposure patterns were defined according to various exposure scenarios. Results We obtained information on exposure parameters and working conditions from the 548 completed questionnaires. The ICNIRP guideline levels were not exceeded in any of the E1–E3 scenarios. Median of the D1 (% ICNIRP RL × hour/week) was 1, and >85% respondents had values <10. However, the maximum value was 513. Altogether, these results indicate that continuous exposure was low in most cases. The same tendency was observed regarding repeated transient exposure from EM-EAS gates (i.e., the median value for D2 (% ICNIRP BR × gate pass) was 5). However, there were several cases in which D1 and D2 values were >10 times the median. The median of D3 (% ICNIRP BR × BCU operation) was 10, and most respondents' D3 values were greater than their D2 values, although the derived results depended on the assumptions made for the estimation. Conclusion We conducted an assessment of combined exposures to IF-EMF and pulsed EMF among library workers in Japan by evaluating both short-term exposures (E1–E3) and exposure indices based on mid-term exposures (D1–D3) assuming actual working conditions per questionnaire results. These results provide useful information for future epidemiological studies.
Collapse
Affiliation(s)
- Sachiko Yamaguchi-Sekino
- Work Environment Research Group, National Institute of Occupational Safety and Health, Kawasaki, Japan
- *Correspondence: Sachiko Yamaguchi-Sekino
| | - Masao Taki
- Department of Systems Design, Tokyo Metropolitan University, Hachioji, Japan
- Electromagnetic Compatibility Laboratory, National Institute of Information and Communications Technology, Koganei, Japan
| | - Miwa Ikuyo
- Department of Systems Design, Tokyo Metropolitan University, Hachioji, Japan
- Electromagnetic Compatibility Laboratory, National Institute of Information and Communications Technology, Koganei, Japan
| | - Kaoru Esaki
- Department of Systems Design, Tokyo Metropolitan University, Hachioji, Japan
- Electromagnetic Compatibility Laboratory, National Institute of Information and Communications Technology, Koganei, Japan
| | - Atsuko Aimoto
- Department of Systems Design, Tokyo Metropolitan University, Hachioji, Japan
| | - Kanako Wake
- Strategic Planning Office, National Institute of Information and Communications Technology, Koganei, Japan
| | - Noriko Kojimahara
- Department of Epidemiology, Shizuoka Graduate University of Public Health, Shizuoka, Japan
| |
Collapse
|
3
|
Influence of Posture and Coil Position on the Safety of a WPT System While Recharging a Compact EV. ENERGIES 2021. [DOI: 10.3390/en14217248] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In this study, the human exposure to the magnetic field emitted by a wireless power transfer (WPT) system during the static recharging operations of a compact electric vehicle (EV) is evaluated. Specifically, the influence of the posture of realistic anatomical models, both in standing and lying positions, either inside or outside the EV, is considered. Aligned and misaligned coil configurations of the WPT system placed both in the rear and front position of the car floor are considered as well. Compliance with safety standards and guidelines has proven that reference levels are exceeded in the extreme case of a person lying on the floor with a hand close to the WPT coils, whereas the system is always compliant with the basic restrictions, at least for the considered scenarios.
Collapse
|
4
|
Tokinobu A, Tanaka K, Arakawa M, Miyake Y. Maternal Use of Induction Heating Cookers During Pregnancy and Birth Outcomes: The Kyushu Okinawa Maternal and Child Health Study. Bioelectromagnetics 2021; 42:329-335. [PMID: 33846994 DOI: 10.1002/bem.22339] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Revised: 01/19/2021] [Accepted: 03/27/2021] [Indexed: 11/09/2022]
Abstract
The effects of exposure to intermediate-frequency electromagnetic fields (IF-EMFs) during pregnancy on birth outcomes are uncertain. We investigated the association between the use of induction heating (IH) cookers, which are major sources of IF-EMFs, during pregnancy and preterm birth (PTB), low birth weight (LBW), small-for-gestational-age (SGA), and birth weight, using data from a prebirth cohort study in Japan. Study participants were 1,565 mothers with singleton pregnancies and the babies born from these pregnancies. We collected the data presented here using self-administered questionnaires. An adjustment was made for maternal age, region of residence, number of children, family structure, maternal education, maternal employment, maternal alcohol intake, smoking during pregnancy, maternal body mass index, baby's sex, and gestational age at birth. IH cooker use during pregnancy was independently associated with a reduced risk of PTB: the adjusted odds ratio was 0.28 (95% confidence interval: 0.07-0.78). IH cooker use during pregnancy was not associated with LBW, SGA, or birth weight. This is the first study to show that IH cooker use during pregnancy is independently inversely associated with PTB.
Collapse
Affiliation(s)
- Akiko Tokinobu
- Department of Epidemiology and Preventive Medicine, Ehime University Graduate School of Medicine, Ehime, Japan.,Center for Data Science, Ehime University, Ehime, Japan
| | - Keiko Tanaka
- Department of Epidemiology and Preventive Medicine, Ehime University Graduate School of Medicine, Ehime, Japan.,Center for Data Science, Ehime University, Ehime, Japan.,Research Promotion Unit, Translational Research Center, Ehime University Hospital, Ehime, Japan
| | - Masashi Arakawa
- Wellness Research Fields, Faculty of Global and Regional Studies, University of the Ryukyus, Okinawa, Japan
| | - Yoshihiro Miyake
- Department of Epidemiology and Preventive Medicine, Ehime University Graduate School of Medicine, Ehime, Japan.,Center for Data Science, Ehime University, Ehime, Japan.,Research Promotion Unit, Translational Research Center, Ehime University Hospital, Ehime, Japan
| |
Collapse
|
5
|
Chassis Influence on the Exposure Assessment of a Compact EV during WPT Recharging Operations. MAGNETOCHEMISTRY 2021. [DOI: 10.3390/magnetochemistry7020025] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In this study, the external magnetic field emitted by a wireless power transfer (WPT) system and the internal electric field induced in human body models during recharging operations of a compact electric vehicle (EV) are evaluated. The magneticfield is calculated with a hybrid scheme coupling the boundary element method with the surface impedance boundary conditions in order to fit the multiscale open-boundary characteristics of the problem. A commercial software is then used to perform numerical dosimetry. Specifically, two realistic anatomical models, both in a driving position and in a standing posture, are considered, and the chassis of the EV is modeled either as a currently employed aluminum alloy and as a futuristic carbon fiber composite panel. Aligned and misaligned coil configurations of the WPT system are considered as well. The analysis of the obtained results shows that the International Commission on Non-Ionizing Radiation Protection (ICNIRP) reference levels are exceeded in the driving position, especially for the carbon fiber chassis, whereas the system is compliant with the basic restrictions, at least for the considered scenarios.
Collapse
|
6
|
Gryz K, Karpowicz J, Zradziński P. Evaluation of the Influence of Magnetic Field on Female Users of an Induction Hob in Ergonomically Sound Exposure Situations. Bioelectromagnetics 2020; 41:500-510. [PMID: 32726484 DOI: 10.1002/bem.22283] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Revised: 06/04/2020] [Accepted: 07/02/2020] [Indexed: 11/12/2022]
Abstract
The hypothesis being tested was that the exposure of female workers to the electromagnetic field (EMF) emitted by an induction hob (IHb) meeting public exposure limitations (evaluated according to EN/IEC 62233) is also compliant with European Directive 2013/35/EU on workers' protection. The electric field induced in three female models in a realistic ergonomically comfortable posture near IHb was evaluated using numerical models of 25 kHz EMF sources (IHb covered by cooking vessels). It was found that, in analyzed ergonomically comfortable exposure situations, the electric field induced in the user's body may exceed public and workers' limits when the vessels do not match the dimensions of IHb's heating zone. This can even be the case when IHb complies with Conformité Européenne labeling requirements (i.e. EMF exposure falls below public limits 30 cm away from IHb edge). In the 36 exposure scenarios analyzed, statistically significant differences were found when the distances from IHb and vessel dimension, and the height and body mass index of models in exposure scenarios varied, but not between the use of models of pregnant and nonpregnant women. The use of IHb complying with European requirements on general public protection does not ensure that EMF exposure to workers complies with the relevant limits. Adequate protection measures need to address these occupational environmental hazards. © 2020 Bioelectromagnetics Society.
Collapse
Affiliation(s)
- Krzysztof Gryz
- Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection, National Research Institute, Warszawa, Poland
| | - Jolanta Karpowicz
- Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection, National Research Institute, Warszawa, Poland
| | - Patryk Zradziński
- Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection, National Research Institute, Warszawa, Poland
| |
Collapse
|
7
|
Effect of Loudspeakers on the In Situ Electric Field in a Driver Body Model Exposed to an Electric Vehicle Wireless Power Transfer System. ENERGIES 2020. [DOI: 10.3390/en13143635] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
This study computationally evaluates the effect of loudspeakers on the in situ electric field in a driver body model exposed to the magnetic field from a wireless power transfer (WPT) system in an electric vehicle (EV), one with a body made of carbon fiber reinforced plastic (CFRP) and the other made with aluminum. A quasi-static two-step approach was applied to compute the in situ electric field. The computational results showed that the magnetic field distribution generated by the WPT is significantly altered around the loudspeakers, and shows obvious discontinuity and local enhancement. The maximum spatial-average magnetic field strength in the driver’s body was increased by 11% in the CFRP vehicle. It was 2.25 times larger than the reference levels (RL) prescribed in the International Commission of Non-Ionizing Radiation Protection (ICNIRP) guidelines in 2010. In addition, we found that the in situ electric field computed by the line- and volume-averaging methods were stable if the top 0.1% voxels are excluded. The maximum value was well below the basic restriction (BR) of the ICNIRP guidelines. Nevertheless, the presence of the loudspeaker led to increments in the electric field strength in parts of the human body, suggesting the potential influence of permissible transmitting power in the WPT system. The maximum electric field strength in the thigh and buttock with the woofer, increased by 27% in the CFRP vehicle. The arm value was up to 3 times higher than that obtained without the tweeter in the aluminum vehicle. Moreover, this study found that the maximum electric field strength depended on the location of the loudspeaker with respect to the WPT system and the separation from the driver model. Therefore, the loudspeaker should be considered when evaluating the maximum in situ electric field strength in the vehicle body design stage.
Collapse
|
8
|
Gaps in Knowledge Relevant to the "Guidelines for Limiting Exposure to Time-Varying Electric and Magnetic Fields (1 Hz-100 kHz)". HEALTH PHYSICS 2020; 118:533-542. [PMID: 32251081 DOI: 10.1097/hp.0000000000001261] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Sources of low-frequency fields are widely found in modern society. All wires or devices carrying or using electricity generate extremely low frequency (ELF) electric fields (EFs) and magnetic fields (MFs), but they decline rapidly with distance to the source. High magnetic flux densities are usually found in the vicinity of power lines and close to equipment using strong electrical currents, but can also be found in buildings with unbalanced return currents, or indoor transformer stations. For decades, epidemiological as well as experimental studies have addressed possible health effects of exposure to ELF-MFs. The main goal of ICNIRP is to protect people and the environment from detrimental exposure to all forms of non-ionizing radiation (NIR). To this end, ICNIRP provides advice and guidance by developing and disseminating exposure guidelines based on the available scientific research. Research in the low-frequency range began more than 40 years ago, and there is now a large body of literature available on which ICNIRP set its protection guidelines. A review of the literature has been carried out to identify possible relevant knowledge gaps, and the aim of this statement is to describe data gaps in research that would, if addressed, assist ICNIRP in further developing guidelines and setting revised recommendations on limiting exposure to electric and magnetic fields. It is articulated in two parts: the main document, which reviews the science related to LF data gaps, and the annex, which explains the methodology used to identify the data gaps.
Collapse
|
9
|
Brech A, Kubinyi G, Németh Z, Bakos J, Fiocchi S, Thuróczy G. Genotoxic effects of intermediate frequency magnetic fields on blood leukocytes in vitro. MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS 2019; 845:403060. [DOI: 10.1016/j.mrgentox.2019.05.016] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Revised: 05/28/2019] [Accepted: 05/29/2019] [Indexed: 01/13/2023]
|
10
|
Nishimura I, Doi Y, Imai N, Kawabe M, Mera Y, Shiina T. Carcinogenicity of intermediate frequency magnetic field in Tg.rasH2 mice. Bioelectromagnetics 2019; 40:160-169. [PMID: 30875092 PMCID: PMC6594107 DOI: 10.1002/bem.22177] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2018] [Accepted: 02/18/2019] [Indexed: 11/11/2022]
Abstract
Although the likelihood of exposure to leaking intermediate frequency magnetic fields (MFs) from electronic devices, such as induction-heating and wireless power transfer systems, has increased, biological data assessing the health risks associated with human exposure remain insufficient. We examined the carcinogenicity of a 20 kHz MF, a typical frequency produced by induction-heating cookers, using a transgenic rasH2 mouse model. Twenty-five male and female CByB6F1-Tg(HRAS)2Jic mice were exposed to a 0.20 mT, 20 kHz MF (22 h/day) or sham-exposed for 26 weeks. As a positive control, 10 male and female rasH2 mice from the same batch were administered a single intraperitoneal injection of 75 mg/kg N-methyl-N-nitrosourea. A blinded histopathological evaluation was performed, and the same experiments were conducted twice, independently, to confirm the reproducibility of the results. Histopathological examination revealed that spontaneous neoplastic lesions, such as splenic hemangiosarcomas and gastric squamous cell papillomas, were less (1-3 per group) in the MF- and sham-exposed groups. The frequency of the neoplastic lesions was not significantly different between the groups. Eight to ten mice in each positive-control group exhibited malignant lymphoma. The outcomes were consistent between duplicated experiments, which indicates lack of carcinogenicity of 20 kHz MF in the rasH2 mouse model. Bioelectromagnetics. © 2019 The Authors. Bioelectromagnetics Published by Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Izumi Nishimura
- Central Research Institute of Electric Power IndustryAbikoJapan
| | - Yuko Doi
- DIMS Institute of Medical ScienceIchinomiyaJapan
| | - Norio Imai
- DIMS Institute of Medical ScienceIchinomiyaJapan
| | | | | | - Takeo Shiina
- Central Research Institute of Electric Power IndustryYokosukaJapan
| |
Collapse
|
11
|
Diao YL, Sun WN, He YQ, Leung SW, Siu YM. Equivalent magnetic vector potential model for low-frequency magnetic exposure assessment. Phys Med Biol 2017; 62:7905-7922. [PMID: 28783037 DOI: 10.1088/1361-6560/aa8490] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
In this paper, a novel source model based on a magnetic vector potential for the assessment of induced electric field strength in a human body exposed to the low-frequency (LF) magnetic field of an electrical appliance is presented. The construction of the vector potential model requires only a single-component magnetic field to be measured close to the appliance under test, hence relieving considerable practical measurement effort-the radial basis functions (RBFs) are adopted for the interpolation of discrete measurements; the magnetic vector potential model can then be directly constructed by summing a set of simple algebraic functions of RBF parameters. The vector potentials are then incorporated into numerical calculations as the equivalent source for evaluations of the induced electric field in the human body model. The accuracy and effectiveness of the proposed model are demonstrated by comparing the induced electric field in a human model to that of the full-wave simulation. This study presents a simple and effective approach for modelling the LF magnetic source. The result of this study could simplify the compliance test procedure for assessing an electrical appliance regarding LF magnetic exposure.
Collapse
Affiliation(s)
- Y L Diao
- College of Electronic Engineering, South China Agricultural University, Guangzhou, People's Republic of China
| | | | | | | | | |
Collapse
|
12
|
Laakso I, Morimoto R, Heinonen J, Jokela K, Hirata A. Human exposure to pulsed fields in the frequency range from 6 to 100 GHz. Phys Med Biol 2017; 62:6980-6992. [PMID: 28791963 DOI: 10.1088/1361-6560/aa81fe] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Restrictions on human exposure to electromagnetic waves at frequencies higher than 3-10 GHz are defined in terms of the incident power density to prevent excessive temperature rise in superficial tissue. However, international standards and guidelines differ in their definitions of how the power density is interpreted for brief exposures. This study investigated how the temperature rise was affected by exposure duration at frequencies higher than 6 GHz. Far-field exposure of the human face to pulses shorter than 10 s at frequencies from 6 to 100 GHz was modelled using the finite-difference time-domain method. The bioheat transfer equation was used for thermal modelling. We investigated the effects of frequency, polarization, exposure duration, and depth below the skin surface on the temperature rise. The results indicated limitations in the current human exposure guidelines and showed that radiant exposure, i.e. energy absorption per unit area, can be used to limit temperature rise for pulsed exposure. The data are useful for the development of human exposure guidelines at frequencies higher than 6 GHz.
Collapse
Affiliation(s)
- Ilkka Laakso
- Department of Electrical Engineering and Automation, Aalto University, Espoo, Finland
| | | | | | | | | |
Collapse
|
13
|
Aerts S, Calderon C, Valič B, Maslanyj M, Addison D, Mee T, Goiceanu C, Verloock L, Van den Bossche M, Gajšek P, Vermeulen R, Röösli M, Cardis E, Martens L, Joseph W. Measurements of intermediate-frequency electric and magnetic fields in households. ENVIRONMENTAL RESEARCH 2017; 154:160-170. [PMID: 28086101 DOI: 10.1016/j.envres.2017.01.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2016] [Revised: 12/22/2016] [Accepted: 01/02/2017] [Indexed: 05/14/2023]
Abstract
Historically, assessment of human exposure to electric and magnetic fields has focused on the extremely-low-frequency (ELF) and radiofrequency (RF) ranges. However, research on the typically emitted fields in the intermediate-frequency (IF) range (300Hz to 1MHz) as well as potential effects of IF fields on the human body remains limited, although the range of household appliances with electrical components working in the IF range has grown significantly (e.g., induction cookers and compact fluorescent lighting). In this study, an extensive measurement survey was performed on the levels of electric and magnetic fields in the IF range typically present in residences as well as emitted by a wide range of household appliances under real-life circumstances. Using spot measurements, residential IF field levels were found to be generally low, while the use of certain appliances at close distance (20cm) may result in a relatively high exposure. Overall, appliance emissions contained either harmonic signals, with fundamental frequencies between 6kHz and 300kHz, which were sometimes accompanied by regions in the IF spectrum of rather noisy, elevated field strengths, or much more capricious spectra, dominated by 50Hz harmonics emanating far in the IF domain. The maximum peak field strengths recorded at 20cm were 41.5V/m and 2.7A/m, both from induction cookers. Finally, none of the appliance emissions in the IF range exceeded the exposure summation rules recommended by the International Commission on Non-Ionizing Radiation Protection guidelines and the International Electrotechnical Commission (IEC 62233) standard at 20cm and beyond (maximum exposure quotients EQE 1.0 and EQH 0.13).
Collapse
Affiliation(s)
- Sam Aerts
- Department of Information Technology, Ghent University/iMinds, iGent, Technologiepark-Zwijnaarde 15, B-9052 Ghent, Belgium.
| | - Carolina Calderon
- Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxon OX11 0RQ, United Kingdom
| | - Blaž Valič
- Institute of Non-Ionizing Radiation (INIS), Pohorskega bataljona 215, Ljubljana 1000, Slovenia
| | - Myron Maslanyj
- Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxon OX11 0RQ, United Kingdom
| | - Darren Addison
- Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxon OX11 0RQ, United Kingdom
| | - Terry Mee
- Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxon OX11 0RQ, United Kingdom
| | - Cristian Goiceanu
- Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxon OX11 0RQ, United Kingdom
| | - Leen Verloock
- Department of Information Technology, Ghent University/iMinds, iGent, Technologiepark-Zwijnaarde 15, B-9052 Ghent, Belgium
| | - Matthias Van den Bossche
- Department of Information Technology, Ghent University/iMinds, iGent, Technologiepark-Zwijnaarde 15, B-9052 Ghent, Belgium
| | - Peter Gajšek
- Institute of Non-Ionizing Radiation (INIS), Pohorskega bataljona 215, Ljubljana 1000, Slovenia
| | - Roel Vermeulen
- Institute for Risk Assessment Sciences, Department of Environmental Epidemiology, Utrecht University, Yalelaan 2, 3508 Utrecht, The Netherlands
| | - Martin Röösli
- Swiss Tropical and Public Health Institute (Swiss TPH), Socinstrasse 57, P.O. Box, 4002 Basel, Switzerland; University of Basel, Petersplatz 1, 4003 Basel, Switzerland
| | - Elisabeth Cardis
- Barcelona Institute for Global Health (ISGlobal) and Municipal Institute of Medical Research (IMIM-Hospital del Mar), Doctor Aiguader, 88, 08003 Barcelona, Spain
| | - Luc Martens
- Department of Information Technology, Ghent University/iMinds, iGent, Technologiepark-Zwijnaarde 15, B-9052 Ghent, Belgium
| | - Wout Joseph
- Department of Information Technology, Ghent University/iMinds, iGent, Technologiepark-Zwijnaarde 15, B-9052 Ghent, Belgium
| |
Collapse
|
14
|
Gajšek P, Ravazzani P, Grellier J, Samaras T, Bakos J, Thuróczy G. Review of Studies Concerning Electromagnetic Field (EMF) Exposure Assessment in Europe: Low Frequency Fields (50 Hz-100 kHz). INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2016; 13:E875. [PMID: 27598182 PMCID: PMC5036708 DOI: 10.3390/ijerph13090875] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 04/20/2016] [Revised: 08/01/2016] [Accepted: 08/23/2016] [Indexed: 11/17/2022]
Abstract
We aimed to review the findings of exposure assessment studies done in European countries on the exposure of the general public to low frequency electric and magnetic fields (EMFs) of various frequencies. The study shows that outdoor average extremely low frequency magnetic fields (ELF-MF) in public areas in urban environments range between 0.05 and 0.2 µT in terms of flux densities, but stronger values (of the order of a few µT) may occur directly beneath high-voltage power lines, at the walls of transformer buildings, and at the boundary fences of substations. In the indoor environment, high values have been measured close to several domestic appliances (up to the mT range), some of which are held close to the body, e.g., hair dryers, electric shavers. Common sources of exposure to intermediate frequencies (IF) include induction cookers, compact fluorescent lamps, inductive charging systems for electric cars and security or anti-theft devices. No systematic measurement surveys or personal exposimetry data for the IF range have been carried out and only a few reports on measurements of EMFs around such devices are mentioned. According to the available European exposure assessment studies, three population exposure categories were classified by the authors regarding the possible future risk analysis. This classification should be considered a crucial advancement for exposure assessment, which is a mandatory step in any future health risk assessment of EMFs exposure.
Collapse
Affiliation(s)
- Peter Gajšek
- Institute of Non-Ionizing Radiation (INIS), Pohorskega Bataljona 215, Ljubljana 1000, Slovenia
| | - Paolo Ravazzani
- Istituto di Elettronica e di Ingegneria dell’Informazione e delle Telecomunicazioni IEIIT, CNR Consiglio Nazionale delle Ricerche, Piazza Leonardo da Vinci 32, Milan 20133, Italy;
| | - James Grellier
- European Centre for Environment and Human Health (ECEHH), University of Exeter Medical School, Knowledge Spa, Royal Cornwall Hospital, Truro, Cornwall TR1 3HD, UK;
- Formerly Centre for Research in Environmental Epidemiology (CREAL), Parc de Recerca Biomèdica de Barcelona, Doctor Aiguader, 88, Barcelona 08003, Spain
| | - Theodoros Samaras
- Formerly Centre for Research in Environmental Epidemiology (CREAL), Parc de Recerca Biomèdica de Barcelona, Doctor Aiguader, 88, Barcelona 08003, Spain
| | - József Bakos
- Department of Physics, Aristotle University of Thessaloniki, Thessaloniki GR-54124, Greece;
| | - György Thuróczy
- Department of Physics, Aristotle University of Thessaloniki, Thessaloniki GR-54124, Greece;
| |
Collapse
|
15
|
Sunohara T, Hirata A, Laakso I, De Santis V, Onishi T. Evaluation of nonuniform field exposures with coupling factors. Phys Med Biol 2015; 60:8129-40. [PMID: 26439390 DOI: 10.1088/0031-9155/60/20/8129] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In this study, the safety compliance for nonuniform field exposures is discussed using coupling factor concepts. The coupling factor, which is defined in the International Electrotechnical Commission 62311 standard, is extended to consider the effects of harmonics and also to apply to the specific absorption rate (for frequencies up to 30 MHz). The proposed compliance procedure is applied to and demonstrated for a prototype wireless power transfer (WPT) system with induction coupling operating at the fundamental frequency in 140 kHz band. First, measurements confirm that the perturbation of the external magnetic field strength and S11 parameter of a one-loop antenna by a human-equivalent phantom are sufficiently small, suggesting the applicability of the magneto-quasi-static approximation to frequencies up to 30 MHz. Then, the frequency characteristics of the coupling factor are derived for the WPT system. For the prototype system that is not optimized for commercial usage, the maximum allowable transmitting power is relaxed by a factor of 23 with the proposed procedure. The contribution of the harmonics decreased the allowable transmitting power by 39%, indicating their importance for safety compliance.
Collapse
Affiliation(s)
- Tetsu Sunohara
- Department of Computer Science and Engineering, Nagoya Institute of Technology, Showa-ku, Gokiso-cho, Nagoya 466-8555, Japan
| | | | | | | | | |
Collapse
|
16
|
Nishimura I, Oshima A, Shibuya K, Mitani T, Negishi T. Acute and subchronic toxicity of 20 kHz and 60 kHz magnetic fields in rats. J Appl Toxicol 2015; 36:199-210. [PMID: 25982482 PMCID: PMC5029766 DOI: 10.1002/jat.3161] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2015] [Revised: 03/10/2015] [Accepted: 03/17/2015] [Indexed: 12/03/2022]
Abstract
Despite increasing use of intermediate frequency (IF) magnetic fields (MFs) in occupational and domestic settings, scientific evidence necessary for health risk assessments of IF MF is insufficient. Male and female Crl:CD(SD) rats (12 per sex per group) were exposed to 20 kHz, 0.20 mT(root mean square, rms) or 60 kHz, 0.10 mT(rms) sinusoidal MFs for 22 h day−1 for 14 days (acute) or 13 weeks (subchronic). Experiments were duplicated for each frequency to ensure outcome reproducibility, and examinations were blinded for quality assurance. All rats survived without significant clinical signs until the end of experiments. Some changes in body weight between the MF‐exposed and control groups were observed over the course of exposure, although the directions of the changes were inconsistent and not statistically significant after subchronic exposure. There were significant differences between MF‐exposed and control groups in some organ weights and parameters in hematology and clinical chemistry, but these were minor in magnitude and not repeated in duplicate experiments. Histopathological findings reflecting toxicity were sporadic. Frequencies of other findings were similar to historic data in this rat strain, and findings had no specific relationship to changes in organ weight or parameters of hematology and clinical chemistry in each animal. The changes observed throughout this study were considered biologically isolated and were attributable to chance associations rather than to MF exposure. The results, in particular the histopathological evidence, indicate an absence of toxicity in IF MF‐exposed rats and do not support the hypothesis that IF MF exposure produces significant toxicity. Copyright © 2015. The Authors. Journal of Applied Toxicology Published by John Wiley & Sons Ltd. Despite increasing use of intermediate frequency (IF) magnetic fields (MFs) in occupational and domestic settings, scientific evidence is insufficient for IF MF health risk assessments. Rats were exposed to 20 kHz or 60 kHz sinusoidal MFs for 22 h day−1 for 14 days (acute) or 13 weeks (subchronic). MF‐exposed rats did not exhibit significant and reproducible changes in body and organ weights, hematology, clinical chemistry and histopathology. Our results indicate that IF MF exposure does not carry a significant health risk to mammals.
Collapse
Affiliation(s)
- Izumi Nishimura
- Environmental Science Research Laboratory, Central Research Institute of Electric Power Industry, Chiba, Japan
| | - Atsushi Oshima
- Contract Testing Department, Nippon Institute for Biological Science, Tokyo, Japan
| | - Kazumoto Shibuya
- Contract Testing Department, Nippon Institute for Biological Science, Tokyo, Japan
| | - Takashi Mitani
- Environmental Science Research Laboratory, Central Research Institute of Electric Power Industry, Chiba, Japan
| | - Tadashi Negishi
- Environmental Science Research Laboratory, Central Research Institute of Electric Power Industry, Chiba, Japan
| |
Collapse
|
17
|
Napp A, Stunder D, Maytin M, Kraus T, Marx N, Driessen S. Are patients with cardiac implants protected against electromagnetic interference in daily life and occupational environment? Eur Heart J 2015; 36:1798-804. [DOI: 10.1093/eurheartj/ehv135] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2014] [Accepted: 04/02/2015] [Indexed: 11/14/2022] Open
|
18
|
Van Den Bossche M, Verloock L, Aerts S, Joseph W, Martens L. In situ exposure assessment of intermediate frequency fields of diverse devices. RADIATION PROTECTION DOSIMETRY 2015; 164:252-264. [PMID: 25125596 DOI: 10.1093/rpd/ncu257] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2014] [Accepted: 07/11/2014] [Indexed: 06/03/2023]
Abstract
In this study, in situ exposure assessment of both electric and magnetic fields of different intermediate frequency (IF) sources is investigated. The authors investigated smart boards and touchscreens, energy-saving bulbs, fluorescent lamps, a portable hearing unit and an electrosurgical unit (ESU). For most of these sources, the electric field is the dominating quantity. International Commission on Non-Ionizing Radiation Protection reference levels are exceeded for touchscreens (44 kHz: up to 155.7 V m(-1) at 5 cm), energy-saving bulbs (38-52 kHz: up to 117.3 V m(-1)), fluorescent lamps (52 kHz: up to 471 V m(-1) at 5 cm) and ESUs (up to 920 kHz: 792 V m(-1) at 0.5 cm). Magnetic field strengths up to 1.8 and 10.5 A m(-1) were measured close to the ESU and portable hearing unit (69 V m(-1)), respectively. Large differences of measured field values exist among the various operating modes of the IF equipment. Compliance distances for general public range from 15.3 cm (touchscreen) to 25 cm (fluorescent lamps).
Collapse
Affiliation(s)
- Matthias Van Den Bossche
- Department of Information Technology, Ghent University/iMinds, Gaston Crommenlaan 8, Box 201, Ghent B-9050, Belgium
| | - Leen Verloock
- Department of Information Technology, Ghent University/iMinds, Gaston Crommenlaan 8, Box 201, Ghent B-9050, Belgium
| | - Sam Aerts
- Department of Information Technology, Ghent University/iMinds, Gaston Crommenlaan 8, Box 201, Ghent B-9050, Belgium
| | - Wout Joseph
- Department of Information Technology, Ghent University/iMinds, Gaston Crommenlaan 8, Box 201, Ghent B-9050, Belgium
| | - Luc Martens
- Department of Information Technology, Ghent University/iMinds, Gaston Crommenlaan 8, Box 201, Ghent B-9050, Belgium
| |
Collapse
|
19
|
Laakso I, Hirata A. Evaluation of the induced electric field and compliance procedure for a wireless power transfer system in an electrical vehicle. Phys Med Biol 2013; 58:7583-93. [PMID: 24107570 DOI: 10.1088/0031-9155/58/21/7583] [Citation(s) in RCA: 61] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In this study, an induced electric field in a human body is evaluated for the magnetic field leaked from a wireless power transfer system for charging an electrical vehicle. The magnetic field from the wireless power transfer system is modelled computationally, and its effectiveness is confirmed by comparison with the field measured in a previous study. The induced electric field in a human standing around the vehicle is smaller than the allowable limit prescribed in international guidelines, although the magnetic field strength in the human body is locally higher than the allowable external field strength. Correlation between the external magnetic field and the induced electric field is confirmed to be reasonable at least in the standing posture, which is the case discussed in the international standard. Based on this finding, we discussed and confirmed the applicability of a three-point magnetic field measurement at heights of 0.5, 1.0, and 1.5 m for safety compliance.
Collapse
Affiliation(s)
- Ilkka Laakso
- Department of Computer Science and Engineering, Nagoya Institute of Technology, Nagoya 466-8555, Japan
| | | |
Collapse
|
20
|
Kos B, Valič B, Kotnik T, Gajšek P. Occupational exposure assessment of magnetic fields generated by induction heating equipment—the role of spatial averaging. Phys Med Biol 2012; 57:5943-53. [DOI: 10.1088/0031-9155/57/19/5943] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
21
|
Christ A, Guldimann R, Bühlmann B, Zefferer M, Bakker JF, van Rhoon GC, Kuster N. Exposure of the Human Body to Professional and Domestic Induction Cooktops Compared to the Basic Restrictions. Bioelectromagnetics 2012; 33:695-705. [DOI: 10.1002/bem.21739] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2011] [Accepted: 05/03/2012] [Indexed: 11/12/2022]
|
22
|
Laakso I, Hirata A. Reducing the staircasing error in computational dosimetry of low-frequency electromagnetic fields. Phys Med Biol 2012; 57:N25-34. [DOI: 10.1088/0031-9155/57/4/n25] [Citation(s) in RCA: 86] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|