1
|
McCredden JE, Weller S, Leach V. The assumption of safety is being used to justify the rollout of 5G technologies. Front Public Health 2023; 11:1058454. [PMID: 36815158 PMCID: PMC9940636 DOI: 10.3389/fpubh.2023.1058454] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Accepted: 01/03/2023] [Indexed: 01/27/2023] Open
Affiliation(s)
- Julie E. McCredden
- Oceania Radiofrequency Scientific Advisory Association Inc. (ORSAA), Scarborough, QLD, Australia
| | - Steven Weller
- Oceania Radiofrequency Scientific Advisory Association Inc. (ORSAA), Scarborough, QLD, Australia,Centre for Environmental and Population Health, School of Medicine and Dentistry, Griffith University, Brisbane, QLD, Australia
| | - Victor Leach
- Oceania Radiofrequency Scientific Advisory Association Inc. (ORSAA), Scarborough, QLD, Australia,*Correspondence: Victor Leach ✉
| |
Collapse
|
2
|
Emission from human skin in the sub THz frequency band. Sci Rep 2022; 12:4720. [PMID: 35304510 PMCID: PMC8933490 DOI: 10.1038/s41598-022-08432-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Accepted: 02/16/2022] [Indexed: 11/09/2022] Open
Abstract
Recently published Radiometric measurements of human subjects in the frequency range 480–700 GHz, demonstrate the emission of blackbody radiation from the body core, rather than the skin surface. We present a detailed electromagnetic simulation of the dermis and epidermis, taking into account the presence of the sweat duct. This complex structure can be considered as an electromagnetic bio-metamaterial, whereby the layered structure, along with the topology of the sweat duct, reveals a complex interference pattern in the skin. The model is capable of accurately representing the skin greyness factor as a function of frequency and this is confirmed by radiometry of living human skin.
Collapse
|
3
|
Verma S, Keshri GK, Karmakar S, Mani KV, Chauhan S, Yadav A, Sharma M, Gupta A. Effects of Microwave 10 GHz Radiation Exposure in the Skin of Rats: An Insight on Molecular Responses. Radiat Res 2021; 196:404-416. [PMID: 34407201 DOI: 10.1667/rade-20-00155.1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Accepted: 08/06/2021] [Indexed: 11/03/2022]
Abstract
Microwave (MW) radiation poses the risk of potential hazards on human health. The present study investigated the effects of MW 10 GHz exposure for 3 h/day for 30 days at power densities of 5.23 ± 0.25 and 10.01 ± 0.15 mW/cm2 in the skin of rats. The animals exposed to 10 mW/cm2 (corresponded to twice the ICNIRP-2020 occupational reference level of MW exposure for humans) exhibited significant biophysical, biochemical, molecular and histological alterations compared to sham-irradiated animals. Infrared thermography revealed an increase in average skin surface temperature by 1.8°C and standard deviation of 0.3°C after 30 days of 10 mW/cm2 MW exposure compared to the sham-irradiated animals. MW exposure also led to oxidative stress (ROS, 4-HNE, LPO, AOPP), inflammatory responses (NFkB, iNOS/NOS2, COX-2) and metabolic alterations [hexokinase (HK), lactate dehydrogenase (LDH), citrate synthase (CS) and glucose-6-phospahte dehydrogenase (G6PD)] in 10 mW/cm2 irradiated rat skin. A significant alteration in expression of markers associated with cell survival (Akt/PKB) and HSP27/p38MAPK-related stress-response signaling cascade was observed in 10 mW/cm2 irradiated rat skin compared to sham-irradiated rat skin. However, MW-irradiated groups did not show apoptosis, evident by unchanged caspase-3 levels. Histopathological analysis revealed a mild cytoarchitectural alteration in epidermal layer and slight aggregation of leukocytes in 10 mW/cm2 irradiated rat skin. Altogether, the present findings demonstrated that 10 GHz exposure in continuous-wave mode at 10 mW/cm2 (3 h/day, 30 days) led to significant alterations in molecular markers associated with adaptive stress-response in rat skin. Furthermore, systematic scientific studies on more prevalent pulsed-mode of MW-radiation exposure for prolonged duration are warranted.
Collapse
Affiliation(s)
- Saurabh Verma
- Defence Institute of Physiology and Allied Sciences (DIPAS), DRDO, Delhi, India
| | - Gaurav K Keshri
- Defence Institute of Physiology and Allied Sciences (DIPAS), DRDO, Delhi, India
| | - Santanu Karmakar
- Microwave Tube Research and Development Centre (MTRDC), DRDO, Bangalore, India
| | - Kumar Vyonkesh Mani
- Defence Institute of Physiology and Allied Sciences (DIPAS), DRDO, Delhi, India
| | - Satish Chauhan
- Defence Institute of Physiology and Allied Sciences (DIPAS), DRDO, Delhi, India
| | - Anju Yadav
- Defence Institute of Physiology and Allied Sciences (DIPAS), DRDO, Delhi, India
| | - Manish Sharma
- Defence Institute of Physiology and Allied Sciences (DIPAS), DRDO, Delhi, India
| | - Asheesh Gupta
- Defence Institute of Physiology and Allied Sciences (DIPAS), DRDO, Delhi, India
| |
Collapse
|
4
|
Betzalel N, Ben Ishai P, Einav S, Feldman Y. The AC conductivity of human sweat ducts as the dominant factor in the sub-THz reflection coefficient of skin. JOURNAL OF BIOPHOTONICS 2021; 14:e202100027. [PMID: 33890427 DOI: 10.1002/jbio.202100027] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Revised: 03/18/2021] [Accepted: 04/05/2021] [Indexed: 06/12/2023]
Abstract
The helical nature of human sweat ducts, combined with the morphological and dielectric properties of skin, suggests electromagnetic activity in the sub-THz frequency band. A detailed electromagnetic simulation model of the skin, with embedded sweat ducts, was created. The model includes realistic dielectric properties based on the measured water content of each layer of skin, derived from Raman Spectroscopy. The model was verified by comparing it to measurements of the reflection coefficient of the palms of 13 volunteers in the frequency band 350-410 GHz. They were subjected to a measurement protocol intended to induce mental stress, thereby also activating the sweat glands. The Galvanic Skin Response was concurrently measured. Using the simulation model the optimal ac-conductivity for each measurement was found. The range of variation for all subjects was found to be from 100 S/m to a maximum value of 6000 S/m with averages of 1000 S/m. These are one order of magnitude increase from the accepted values for water at these frequencies (~100 s/m at 100 GHz). Considering the known biochemical mechanism for inducing perspiration, we conclude that these ac-conductivity levels are probably valid, even though the real time measurements of sweat ac-conductivity levels inside the duct are inaccessible.
Collapse
Affiliation(s)
- Noa Betzalel
- The Department of Applied Physics, The Hebrew University of Jerusalem, Jerusalem, Israel
| | - Paul Ben Ishai
- The Department of Physics, Ariel University, Ariel, Israel
| | - Sharon Einav
- The Intensive Care Unit, Shaare Zedek Medical Center, Faculty of Medicine, Hebrew University, Jerusalem, Israel
| | - Yuri Feldman
- The Department of Applied Physics, The Hebrew University of Jerusalem, Jerusalem, Israel
| |
Collapse
|
5
|
Betzalel N, Feldman Y, Ben Ishai P. Response to the comment of Foster et al. titled "Comments on Betzalel et al. "The human skin as a sub-THz receiver-Does 5G pose a danger to it or not?" [Environ. Res. 163 (2018): 208-216]". ENVIRONMENTAL RESEARCH 2020; 182:109016. [PMID: 31863940 DOI: 10.1016/j.envres.2019.109016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Accepted: 12/06/2019] [Indexed: 06/10/2023]
Affiliation(s)
- Noa Betzalel
- Department of Applied Physics, The Hebrew University of Jerusalem, Jerusalem, Israel
| | - Yuri Feldman
- Department of Applied Physics, The Hebrew University of Jerusalem, Jerusalem, Israel
| | | |
Collapse
|
6
|
Simkó M, Mattsson MO. 5G Wireless Communication and Health Effects-A Pragmatic Review Based on Available Studies Regarding 6 to 100 GHz. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:E3406. [PMID: 31540320 PMCID: PMC6765906 DOI: 10.3390/ijerph16183406] [Citation(s) in RCA: 68] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/19/2019] [Revised: 09/09/2019] [Accepted: 09/11/2019] [Indexed: 02/07/2023]
Abstract
The introduction of the fifth generation (5G) of wireless communication will increase the number of high-frequency-powered base stations and other devices. The question is if such higher frequencies (in this review, 6-100 GHz, millimeter waves, MMW) can have a health impact. This review analyzed 94 relevant publications performing in vivo or in vitro investigations. Each study was characterized for: study type (in vivo, in vitro), biological material (species, cell type, etc.), biological endpoint, exposure (frequency, exposure duration, power density), results, and certain quality criteria. Eighty percent of the in vivo studies showed responses to exposure, while 58% of the in vitro studies demonstrated effects. The responses affected all biological endpoints studied. There was no consistent relationship between power density, exposure duration, or frequency, and exposure effects. The available studies do not provide adequate and sufficient information for a meaningful safety assessment, or for the question about non-thermal effects. There is a need for research regarding local heat developments on small surfaces, e.g., skin or the eye, and on any environmental impact. Our quality analysis shows that for future studies to be useful for safety assessment, design and implementation need to be significantly improved.
Collapse
Affiliation(s)
- Myrtill Simkó
- SciProof International AB, Vaktpoststigen 4, 83132 Östersund, Sweden.
| | | |
Collapse
|
7
|
Guhl C, Birklein F, Hirsch S. Sweating disorders in mice with and without nerve lesions. Eur J Pain 2018; 23:835-842. [PMID: 30582875 DOI: 10.1002/ejp.1352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2018] [Revised: 12/12/2018] [Accepted: 12/18/2018] [Indexed: 11/11/2022]
Abstract
BACKGROUND Hypersensitivity and altered sweating are often present in neuropathy patients. Nerve lesions are known to produce sudomotor dysfunctions but also patients suffering from complex regional pain syndrome, CRPS1-a condition without a nerve lesion-present with sweating disorders. METHODS Using proton nuclear magnetic resonance of sweat water, we quantified sweat output of mice suffering from a nerve lesion or a bone fracture without nerve lesion and correlated their sweating with behavioural paw hypersensitivity accessed in von Frey testings, water applications and weight-bearing measured with an incapacitance metre. RESULTS Lesioned animals sweat less and are hypersensitive compared to healthy controls, as expected. Fractured animals on the injured side sweat less acutely after the injury but more in the chronic phase. They are hypersensitive acutely as well as chronically after the fracture. These findings resemble human bone trauma patients in the acute phase and CRPS patients in the chronic phase. CONCLUSIONS Sweating disorders are present both in neuropathic animals and in those with a bone fracture without nerve lesions, and autonomic dysfunctions might be considered as an important component in the aetiology of neuropathies. SIGNIFICANCE Sweat output changes in mice after bone trauma, potentially indicative of posttraumatic processes leading to CRPS in humans.
Collapse
Affiliation(s)
- Charlotte Guhl
- Klinik und Poliklinik für Neurologie, Unimedizin Mainz, Mainz, Germany
| | - Frank Birklein
- Klinik und Poliklinik für Neurologie, Unimedizin Mainz, Mainz, Germany
| | - Silke Hirsch
- Klinik und Poliklinik für Neurologie, Unimedizin Mainz, Mainz, Germany
| |
Collapse
|
8
|
Tripathi SR, Ben Ishai P, Kawase K. Frequency of the resonance of the human sweat duct in a normal mode of operation. BIOMEDICAL OPTICS EXPRESS 2018; 9:1301-1308. [PMID: 29541522 PMCID: PMC5846532 DOI: 10.1364/boe.9.001301] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Revised: 02/13/2018] [Accepted: 02/13/2018] [Indexed: 06/12/2023]
Abstract
The applications of terahertz (THz) waves have been increasing rapidly in different fields such as information and communication technology, homeland security and biomedical engineering. However, study on the possible health implications due to various biological effects induced by THz waves is relatively scarce. Previously, it has been reported that the human sweat ducts play a significant role in the interaction of the THz wave with human skin due to its coiled structure. This structure imposes on them the electromagnetic character of a helical antenna. To further understand these phenomena, we investigated the morphological features of human sweat ducts and the dielectric properties of their surrounding medium. Based upon these parameters, we estimated the frequency of the resonance of the human sweat duct in a normal mode of operation and our estimation showed that there is a broad resonance around 228 GHz. This result indicates that careful consideration should be given while designing electronic and photonic devices operating in the sub-terahertz frequency region in order to avoid various effects on human health due to these waves.
Collapse
Affiliation(s)
- Saroj R. Tripathi
- Department of Mechanical Engineering, Shizuoka University, 3-5-1 Johoku, Hamamatsu, Shizuoka 432-8561 Japan
| | - Paul Ben Ishai
- Department of Physics, Ariel University, P.O.B. 3, Ariel 40700, Israel
| | - Kodo Kawase
- Department of Electronics, Nagoya University, Furo cho, Chikusa ku, Nagoya 464-8603 Japan
| |
Collapse
|
9
|
Memic A, Navaei A, Mirani B, Cordova JAV, Aldhahri M, Dolatshahi-Pirouz A, Akbari M, Nikkhah M. Bioprinting technologies for disease modeling. Biotechnol Lett 2017; 39:1279-1290. [PMID: 28550360 DOI: 10.1007/s10529-017-2360-z] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2017] [Accepted: 05/04/2017] [Indexed: 12/12/2022]
Abstract
There is a great need for the development of biomimetic human tissue models that allow elucidation of the pathophysiological conditions involved in disease initiation and progression. Conventional two-dimensional (2D) in vitro assays and animal models have been unable to fully recapitulate the critical characteristics of human physiology. Alternatively, three-dimensional (3D) tissue models are often developed in a low-throughput manner and lack crucial native-like architecture. The recent emergence of bioprinting technologies has enabled creating 3D tissue models that address the critical challenges of conventional in vitro assays through the development of custom bioinks and patient derived cells coupled with well-defined arrangements of biomaterials. Here, we provide an overview on the technological aspects of 3D bioprinting technique and discuss how the development of bioprinted tissue models have propelled our understanding of diseases' characteristics (i.e. initiation and progression). The future perspectives on the use of bioprinted 3D tissue models for drug discovery application are also highlighted.
Collapse
Affiliation(s)
- Adnan Memic
- Center of Nanotechnology, King Abdulaziz University, Jeddah, Saudi Arabia.,Biomaterials Research Innovation Center, Harvard Medical School, Brigham and Women's Hospital, Cambridge, MA, USA
| | - Ali Navaei
- School of Biological and Health Systems Engineering (SBHSE), Arizona State University, Tempe, AZ, USA
| | - Bahram Mirani
- Center for Biomedical Research, University of Victoria, Victoria, Canada.,Centre for Advanced Materials and Related Technology (CAMTEC), University of Victoria, Victoria, Canada
| | | | - Musab Aldhahri
- Center of Nanotechnology, King Abdulaziz University, Jeddah, Saudi Arabia.,Department of Biochemistry, Faculty of Science, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Alireza Dolatshahi-Pirouz
- Center for Nanomedicine and Theranostics, Technical University of Denmark, DTU Nanotech, 2800, Lyngby, Denmark
| | - Mohsen Akbari
- Center for Biomedical Research, University of Victoria, Victoria, Canada.,Centre for Advanced Materials and Related Technology (CAMTEC), University of Victoria, Victoria, Canada
| | - Mehdi Nikkhah
- School of Biological and Health Systems Engineering (SBHSE), Arizona State University, Tempe, AZ, USA.
| |
Collapse
|
10
|
Tripathi SR, Miyata E, Ishai PB, Kawase K. Morphology of human sweat ducts observed by optical coherence tomography and their frequency of resonance in the terahertz frequency region. Sci Rep 2015; 5:9071. [PMID: 25766116 PMCID: PMC4357862 DOI: 10.1038/srep09071] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2014] [Accepted: 02/17/2015] [Indexed: 11/09/2022] Open
Abstract
It is crucial to understand the various biological effects induced by terahertz (THz) electromagnetic waves with the rapid development of electronic and photonic devices operating in the THz frequency region. The presence of sweat glands plays an important role in THz wave interactions with human skin. We investigated the morphological features of sweat ducts using optical coherence tomography (OCT) to further understand such phenomena. We observed remarkable features of the ducts, such as their clear helical structure. The intersubject and intrasubject variations in the diameter of sweat ducts were considerably smaller than the variations in other structural parameters, such as length and number of turns. Based on the sweat duct dimensions and THz dielectric properties of skin measured using terahertz time-domain spectroscopy (THz-TDS), we calculated the resonating frequency of the sweat duct under the assumption of it functioning as a helical antenna. Here, we show that the resonance frequency in the axial mode of operation lies in the THz wave region with a centre frequency of 0.44 ± 0.07 THz. We expect that these findings will further our understanding of the various health consequences of the interaction of THz waves with human beings.
Collapse
Affiliation(s)
| | - Eisuke Miyata
- Nagoya University, Furo-cho, Chikusa Ku, Nagoya 464-8603, Japan
| | - Paul Ben Ishai
- The Hebrew University of Jerusalem, Givat Ram, Jerusalem 91904, Israel
| | - Kodo Kawase
- Nagoya University, Furo-cho, Chikusa Ku, Nagoya 464-8603, Japan
- RIKEN, 519-1399 Aramakiaoba, Aoba, Sendai 980-0845, Japan
| |
Collapse
|
11
|
Ney M, Abdulhalim I. Ultrahigh polarimetric image contrast enhancement for skin cancer diagnosis using InN plasmonic nanoparticles in the terahertz range. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:125007. [PMID: 26720872 DOI: 10.1117/1.jbo.20.12.125007] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2015] [Accepted: 11/24/2015] [Indexed: 05/13/2023]
Abstract
Mueller matrix imaging sensitivity, to delicate water content changes in tissue associated with early stages of skin cancer, is demonstrated by numerical modeling to be enhanced by localized surface plasmon resonance (LSPR) effects at the terahertz (THz) range when InN nanoparticles (NPs) coated with Parylene-C are introduced into the skin. A skin tissue model tailored for THz wavelengths is established for a Monte Carlo simulation of polarized light propagation and scattering, and a comparative study based on simulated Mueller matrices is presented considering different NPs’ parameters and insertion into the skin methods. The insertion of NPs presenting LSPR in the THz is demonstrated to enable the application of polarization-based sample characterization techniques adopted from the scattering dominated visible wavelengths domain for the, otherwise, relatively low scattering THz domain, where such approach is irrelevant without the NPs. Through these Mueller polarimetry techniques, the detection of water content variations in the tissue is made possible and with high sensitivity. This study yields a limit of detection down to 0.0018% for relative changes in the water content based on linear degree of polarization--an improvement of an order of magnitude relative to the limit of detection without NPs calculated in a previous ellipsometric study.
Collapse
|
12
|
Gekle S, Netz RR. Nanometer-resolved radio-frequency absorption and heating in biomembrane hydration layers. J Phys Chem B 2014; 118:4963-9. [PMID: 24779642 DOI: 10.1021/jp501562p] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Radio-frequency (RF) electromagnetic fields are readily absorbed in biological matter and lead to dielectric heating. To understand how RF radiation interacts with macromolecular structures and possibly influences biological function, a quantitative description of dielectric absorption and heating at nanometer resolution beyond the usual effective medium approach is crucial. We report an exemplary multiscale theoretical study for biomembranes that combines (i) atomistic simulations for the spatially resolved absorption spectrum at a single planar DPPC lipid bilayer immersed in water, (ii) calculation of the electric field distribution in planar and spherical cell models, and (iii) prediction of the nanometer resolved temperature profiles under steady RF radiation. Our atomistic simulations show that the only 2 nm thick lipid hydration layer strongly absorbs in a wide RF range between 10 MHz and 100 GHz. The absorption strength, however, strongly depends on the direction of the incident wave. This requires modeling of the electric field distribution using tensorial dielectric spectral functions. For a spherical cell model, we find a strongly enhanced RF absorption on an equatorial ring, which gives rise to temperature gradients inside a single cell under radiation. Although absolute temperature elevation is small under conditions of typical telecommunication usage, our study points to hitherto neglected temperature gradient effects and allows thermal RF effects to be predicted on an atomistically resolved level. In addition to a refined physiological risk assessment of RF fields, technological applications for controlling temperature profiles in nanodevices are possible.
Collapse
Affiliation(s)
- Stephan Gekle
- Fachbereich Physik, Universität Bayreuth , Bayreuth, Germany
| | | |
Collapse
|
13
|
Hayut I, Ben Ishai P, Agranat AJ, Feldman Y. Circular polarization induced by the three-dimensional chiral structure of human sweat ducts. PHYSICAL REVIEW. E, STATISTICAL, NONLINEAR, AND SOFT MATTER PHYSICS 2014; 89:042715. [PMID: 24827286 DOI: 10.1103/physreve.89.042715] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2013] [Indexed: 06/03/2023]
Abstract
The upper part of the human eccrine sweat ducts, embedded within the epidermis layer, have a well-defined helical structure. It was recently suggested that, as electromagnetic entities, the sweat ducts interact with sub-mm waves [Y. Feldman et al., Phys. Rev. Lett. 100, 128102 (2008)]. Although correlation between changes in the reflectance spectrum in this frequency range and physiological activities has been shown, a direct link between the electromagnetic reflection and the helical structure itself has remained to be established. The fact that the sweat ducts manifest natural homochirality is henceforth used to produce this link. We report the detection of circular polarization asymmetry in the electromagnetic reflection from the human skin at sub-THz frequencies in vivo. We compare the results to numerical simulations and to measurements of a fabricated metamaterial. We argue that the observed circular dichroism can be interpreted uniquely as the signature of the helical structure itself. By twisting reflected electromagnetic waves, the human skin exhibits properties which are usually discussed only in the framework of metamaterial science.
Collapse
Affiliation(s)
- Itai Hayut
- Department of Applied Physics, The Hebrew University of Jerusalem, Jerusalem 91904, Israel
| | - Paul Ben Ishai
- Department of Applied Physics, The Hebrew University of Jerusalem, Jerusalem 91904, Israel
| | - Aharon J Agranat
- Department of Applied Physics, The Hebrew University of Jerusalem, Jerusalem 91904, Israel
| | - Yuri Feldman
- Department of Applied Physics, The Hebrew University of Jerusalem, Jerusalem 91904, Israel
| |
Collapse
|
14
|
Zilberti L, Arduino A, Bottauscio O, Chiampi M. Parametric analysis of transient skin heating induced by terahertz radiation. Bioelectromagnetics 2014; 35:314-23. [PMID: 24510310 DOI: 10.1002/bem.21842] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2013] [Accepted: 01/09/2014] [Indexed: 12/17/2022]
Abstract
This paper investigates the effect of relevant physical parameters on transient temperature elevation induced in human tissues by electromagnetic waves in the terahertz (THz) band. The problem is defined by assuming a plane wave, which, during a limited time interval, normally impinges on the surface of a 3-layer model of the human body, causing a thermal transient. The electromagnetic equations are solved analytically, while the thermal ones are handled according to the finite element method. A parametric analysis is performed with the aim of identifying the contribution of each parameter, showing that the properties of the first skin layer (except blood flow) play a major role in the computation of the maximum temperature rise for the considered exposure situation. Final results, obtained by combining all relevant parameters together, show that the deviation from the reference solution of the maximum temperature elevation in skin is included in the coverage intervals from -30% to +10% at 0.1 THz and from -33% to +18% at 1 THz (with 95% confidence level). These data allow bounding the possible temperature increase against the spread of tissue properties that could be reasonably used for dosimetric simulations.
Collapse
Affiliation(s)
- Luca Zilberti
- Istituto Nazionale di Ricerca Metrologica (National Institute of Metrological Research), Torino, Italy
| | | | | | | |
Collapse
|
15
|
Karampatzakis A, Samaras T. Numerical modeling of heat and mass transfer in the human eye under millimeter wave exposure. Bioelectromagnetics 2013; 34:291-9. [DOI: 10.1002/bem.21774] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2012] [Accepted: 11/28/2012] [Indexed: 11/10/2022]
|
16
|
Safrai E, Ishai PB, Caduff A, Puzenko A, Polsman A, Agranat AJ, Feldman Y. The remote sensing of mental stress from the electromagnetic reflection coefficient of human skin in the sub-THz range. Bioelectromagnetics 2011; 33:375-82. [DOI: 10.1002/bem.21698] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2011] [Accepted: 10/21/2011] [Indexed: 11/12/2022]
|