Flores JD, Gang GJ, Zhang H, Lin CT, Fung SK, Stayman JW. Direct reconstruction of anatomical change in low-dose lung nodule surveillance. J Med Imaging (Bellingham) 2021; 8:023503. [PMID: 33846692 DOI: 10.1117/1.jmi.8.2.023503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Accepted: 03/18/2021] [Indexed: 11/14/2022] Open
Abstract
Purpose: In sequential imaging studies, there exists rich information from past studies that can be used in prior-image-based reconstruction (PIBR) as a form of improved regularization to yield higher-quality images in subsequent studies. PIBR methods, such as reconstruction of difference (RoD), have demonstrated great improvements in the image quality of subsequent anatomy reconstruction even when CT data are acquired at very low-exposure settings. Approach: However, to effectively use information from past studies, two major elements are required: (1) registration, usually deformable, must be applied between the current and prior scans. Such registration is greatly complicated by potential ambiguity between patient motion and anatomical change-which is often the target of the followup study. (2) One must select regularization parameters for reliable and robust reconstruction of features. Results: We address these two major issues and apply a modified RoD framework to the clinical problem of lung nodule surveillance. Specifically, we develop a modified deformable registration approach that enforces a locally smooth/rigid registration around the change region and extend previous analytic expressions relating reconstructed contrast to the regularization parameter and other system dependencies for reliable representation of image features. We demonstrate the efficacy of this approach using a combination of realistic digital phantoms and clinical projection data. Performance is characterized as a function of the size of the locally smooth registration region of interest as well as x-ray exposure. Conclusions: This modified framework is effectively able to separate patient motion and anatomical change to directly highlight anatomical change in lung nodule surveillance.
Collapse
Affiliation(s)
- Jessica D Flores
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
| | - Grace J Gang
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
| | - Hao Zhang
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
| | - Cheng T Lin
- Johns Hopkins University, Department of Radiology, Baltimore, Maryland, United States
| | | | - J Webster Stayman
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
| |
Collapse
|
2
|
Wang W, Gang GJ, Siewerdsen JH, Levinson R, Kawamoto S, Stayman JW. Volume-of-interest imaging with dynamic fluence modulation using multiple aperture devices. J Med Imaging (Bellingham) 2019; 6:033504. [PMID: 31528659 DOI: 10.1117/1.jmi.6.3.033504] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2019] [Accepted: 08/20/2019] [Indexed: 11/14/2022] Open
Abstract
Volume-of-interest (VOI) imaging is a strategy in computed tomography (CT) that restricts x-ray fluence to particular anatomical targets via dynamic beam modulation. This permits dose reduction while retaining image quality within the VOI. VOI-CT implementation has been challenged, in part, by a lack of hardware solutions for tailoring the incident fluence to the patient and anatomical site, as well as difficulties involving interior tomography reconstruction of truncated projection data. We propose a general VOI-CT imaging framework using multiple aperture devices (MADs), an emerging beam filtration scheme based on two binary x-ray filters. Location of the VOI is prescribed using two scout views at anterior-posterior (AP) and lateral perspectives. Based on a calibration of achievable fluence field patterns, MAD motion trajectories were designed using an optimization objective that seeks to maximize the relative fluence in the VOI subject to minimum fluence constraints. A modified penalized-likelihood method is developed for reconstruction of heavily truncated data using the full-field scout views to help solve the interior tomography problem. Physical experiments were conducted to show the feasibility of noncentered and elliptical VOI in two applications-spine and lung imaging. Improved dose utilization and retained image quality are validated with respect to standard full-field protocols. We observe that the contrast-to-noise ratio (CNR) is 40% higher compared with low-dose full-field scans at the same dose. The total dose reduction is 50% for equivalent image quality (CNR) within the VOI.
Collapse
Affiliation(s)
- Wenying Wang
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
| | - Grace J Gang
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
| | - Jeffrey H Siewerdsen
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
| | | | - Satomi Kawamoto
- Johns Hopkins University, Department of Radiology and Radiology Science, Baltimore, Maryland, United States
| | - J Webster Stayman
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
| |
Collapse
|
3
|
Park S, Plishker W, Quon H, Wong J, Shekhar R, Lee J. Deformable registration of CT and cone-beam CT with local intensity matching. Phys Med Biol 2017; 62:927-947. [PMID: 28074785 DOI: 10.1088/1361-6560/aa4f6d] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Cone-beam CT (CBCT) is a widely used intra-operative imaging modality in image-guided radiotherapy and surgery. A short scan followed by a filtered-backprojection is typically used for CBCT reconstruction. While data on the mid-plane (plane of source-detector rotation) is complete, off-mid-planes undergo different information deficiency and the computed reconstructions are approximate. This causes different reconstruction artifacts at off-mid-planes depending on slice locations, and therefore impedes accurate registration between CT and CBCT. In this paper, we propose a method to accurately register CT and CBCT by iteratively matching local CT and CBCT intensities. We correct CBCT intensities by matching local intensity histograms slice by slice in conjunction with intensity-based deformable registration. The correction-registration steps are repeated in an alternating way until the result image converges. We integrate the intensity matching into three different deformable registration methods, B-spline, demons, and optical flow that are widely used for CT-CBCT registration. All three registration methods were implemented on a graphics processing unit for efficient parallel computation. We tested the proposed methods on twenty five head and neck cancer cases and compared the performance with state-of-the-art registration methods. Normalized cross correlation (NCC), structural similarity index (SSIM), and target registration error (TRE) were computed to evaluate the registration performance. Our method produced overall NCC of 0.96, SSIM of 0.94, and TRE of 2.26 → 2.27 mm, outperforming existing methods by 9%, 12%, and 27%, respectively. Experimental results also show that our method performs consistently and is more accurate than existing algorithms, and also computationally efficient.
Collapse
Affiliation(s)
- Seyoun Park
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD, USA
| | | | | | | | | | | |
Collapse
|
4
|
Pourmorteza A, Dang H, Siewerdsen JH, Stayman JW. Reconstruction of difference in sequential CT studies using penalized likelihood estimation. Phys Med Biol 2016; 61:1986-2002. [PMID: 26894795 PMCID: PMC4948746 DOI: 10.1088/0031-9155/61/5/1986] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Characterization of anatomical change and other differences is important in sequential computed tomography (CT) imaging, where a high-fidelity patient-specific prior image is typically present, but is not used, in the reconstruction of subsequent anatomical states. Here, we introduce a penalized likelihood (PL) method called reconstruction of difference (RoD) to directly reconstruct a difference image volume using both the current projection data and the (unregistered) prior image integrated into the forward model for the measurement data. The algorithm utilizes an alternating minimization to find both the registration and reconstruction estimates. This formulation allows direct control over the image properties of the difference image, permitting regularization strategies that inhibit noise and structural differences due to inconsistencies between the prior image and the current data. Additionally, if the change is known to be local, RoD allows local acquisition and reconstruction, as opposed to traditional model-based approaches that require a full support field of view (or other modifications). We compared the performance of RoD to a standard PL algorithm, in simulation studies and using test-bench cone-beam CT data. The performances of local and global RoD approaches were similar, with local RoD providing a significant computational speedup. In comparison across a range of data with differing fidelity, the local RoD approach consistently showed lower error (with respect to a truth image) than PL in both noisy data and sparsely sampled projection scenarios. In a study of the prior image registration performance of RoD, a clinically reasonable capture ranges were demonstrated. Lastly, the registration algorithm had a broad capture range and the error for reconstruction of CT data was 35% and 20% less than filtered back-projection for RoD and PL, respectively. The RoD has potential for delivering high-quality difference images in a range of sequential clinical scenarios including image-guided surgeries and treatments where accurate and quantitative assessments of anatomical change is desired.
Collapse
Affiliation(s)
- A Pourmorteza
- Department of Radiology and Imaging Sciences, National Institutes of Health Clinical Center, Bethesda, MD 20814, USA
| | - H Dang
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
| | - J H Siewerdsen
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
| | - J W Stayman
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
| |
Collapse
|
5
|
Flach B, Brehm M, Sawall S, Kachelrieß M. Deformable 3D–2D registration for CT and its application to low dose tomographic fluoroscopy. Phys Med Biol 2014; 59:7865-87. [DOI: 10.1088/0031-9155/59/24/7865] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
6
|
Ali I, Alsbou N, Algan O, Herman T, Ahmad S. Quantitative assessment by measurement and modeling of mobile target elongation in cone-beam computed tomographic imaging. J Appl Clin Med Phys 2014; 15:4634. [PMID: 24892334 PMCID: PMC5711045 DOI: 10.1120/jacmp.v15i3.4634] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2013] [Revised: 02/07/2014] [Accepted: 12/30/2013] [Indexed: 11/23/2022] Open
Abstract
The purpose of this study was to assess quantitatively elongation of mobile targets in cone‐beam CT (CBCT) imaging by measurement and modeling. A mathematical model was derived that predicts the measured lengths of mobile targets and its dependence on target size and motion patterns in CBCT imaging. Three tissue‐equivalent targets of differing sizes were inserted in an artificial thorax phantom to simulate lung lesions. Respiratory motion was mimicked with a mobile phantom that moves in one‐dimension along the superior‐inferior direction at a respiration frequency of 0.24 Hz for eight different amplitudes in the range 0‐40 mm. A mathematical model was derived to quantify the variations in target lengths and its dependence on phantom motion parameters in CBCT. Predictions of the model were verified by measurement of the lengths of mobile targets in CBCT images. The model predicts that target lengths increased linearly with increase in speed and amplitude of phantom motion in CBCT. The measured lengths of mobile targets imaged with CBCT agreed with the calculated lengths within half‐slice thickness spatial resolution. The maximal length of a mobile target was independent of the frequency and phase of motion. Elongation of mobile targets was similar in halffan and full‐fan CBCT for similar motion patterns, as long as the targets remained within the imaging view. Mobile targets elongated linearly with phantom speed and motion amplitude in CBCT imaging. The model introduced in this work assessed quantitatively the variation in target lengths induced by motion, which may be a useful tool to consider elongations of mobile targets in CBCT applications in diagnostic imaging and radiotherapy. PACS number: 87.57.qp
Collapse
Affiliation(s)
- Imad Ali
- University of Oklahoma Health Sciences Center.
| | | | | | | | | |
Collapse
|
7
|
Van Eyndhoven G, Batenburg KJ, Sijbers J. Region-Based Iterative Reconstruction of Structurally Changing Objects in CT. IEEE TRANSACTIONS ON IMAGE PROCESSING : A PUBLICATION OF THE IEEE SIGNAL PROCESSING SOCIETY 2014; 23:909-919. [PMID: 26270927 DOI: 10.1109/tip.2013.2297024] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
X-ray computed tomography (CT) is a powerful tool for noninvasive imaging of time-varying objects. In the past, methods have been proposed to reconstruct images from continuously changing objects. For discretely or structurally changing objects, however, such methods fail to reconstruct high quality images, mainly because assumptions about continuity are no longer valid. In this paper, we propose a method to reconstruct structurally changing objects. Starting from the observation that there exist regions within the scanned object that remain unchanged over time, we introduce an iterative optimization routine that can automatically determine these regions and incorporate this knowledge in an algebraic reconstruction method. The proposed algorithm was validated on simulation data and experimental μCT data, illustrating its capability to reconstruct structurally changing objects more accurately in comparison to current techniques.
Collapse
|
8
|
Flach B, Kuntz J, Brehm M, Kueres R, Bartling S, Kachelrieß M. Low dose tomographic fluoroscopy: 4D intervention guidance with running prior. Med Phys 2013; 40:101909. [DOI: 10.1118/1.4819826] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
|
9
|
Abstract
We present an approximate truncation robust algorithm to compute tomographic images (ATRACT). This algorithm targets at reconstructing volumetric images from cone-beam projections in scenarios where these projections are highly truncated in each dimension. It thus facilitates reconstructions of small subvolumes of interest, without involving prior knowledge about the object. Our method is readily applicable to medical C-arm imaging, where it may contribute to new clinical workflows together with a considerable reduction of x-ray dose. We give a detailed derivation of ATRACT that starts from the conventional Feldkamp filtered-backprojection algorithm and that involves, as one component, a novel original formula for the inversion of the two-dimensional Radon transform. Discretization and numerical implementation are discussed and reconstruction results from both, simulated projections and first clinical data sets are presented.
Collapse
|