1
|
Żołek N, Rix H, Botwicz M. Analysis of estimation of optical properties of sub superficial structures in multi layered tissue model using distribution function method. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2020; 183:105084. [PMID: 31580969 DOI: 10.1016/j.cmpb.2019.105084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Revised: 09/02/2019] [Accepted: 09/17/2019] [Indexed: 06/10/2023]
Abstract
BACKGROUND AND OBJECTIVE This paper is focused on the analysis of a method of estimation of the absorption and scattering coefficients of nonhomogeneous two layered structures in time resolved near infrared spectroscopy using method based on cumulative distributions of time of flight of photons. METHODS The research is based on the analysis of the superposition of cumulative distributions of time of flight of photons. This approach allows for detailed analysis of small variations in characteristics of time of flight of photons caused by an electromagnetic propagation in highly scattering non-homogeneous media. The method presented, based on the variation of statistical minimum distance estimation, is compared to the method of standard curve fitting. It is analyzed by fitting the results obtained from Monte-Carlo simulations of light propagation in the turbid medium to the data from the simulated measurements. RESULTS The analysis is carried out for a vast range of optical properties of two layered medium in reflectance geometry. CONCLUSIONS The method allows the estimation of the optical parameters despite the noise in the measured signal, with higher accuracy and generally with smaller number of error function evaluations.
Collapse
Affiliation(s)
- Norbert Żołek
- Institute of Biocybernetics and Biomedical Engineering Polish Academy of Sciences, Warsaw, Poland; Institute of Fundamental Technological Research Polish Academy of Sciences, Warsaw, Poland.
| | - Hervé Rix
- Laboratoire d'Informatique, Signaux et Systèmes de Sophia Antipolis (I3S), Sophia Antipolis, France
| | - Marcin Botwicz
- Institute of Biocybernetics and Biomedical Engineering Polish Academy of Sciences, Warsaw, Poland
| |
Collapse
|
2
|
Chang Z, Liu F, Wang L, Deng M, Zhou C, Sun Q, Chu J. Near-infrared dyes, nanomaterials and proteins. CHINESE CHEM LETT 2019. [DOI: 10.1016/j.cclet.2019.08.034] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
3
|
Abstract
This article reviews the past and current statuses of time-domain near-infrared spectroscopy (TD-NIRS) and imaging. Although time-domain technology is not yet widely employed due to its drawbacks of being cumbersome, bulky, and very expensive compared to commercial continuous wave (CW) and frequency-domain (FD) fNIRS systems, TD-NIRS has great advantages over CW and FD systems because time-resolved data measured by TD systems contain the richest information about optical properties inside measured objects. This article focuses on reviewing the theoretical background, advanced theories and methods, instruments, and studies on clinical applications for TD-NIRS including some clinical studies which used TD-NIRS systems. Major events in the development of TD-NIRS and imaging are identified and summarized in chronological tables and figures. Finally, prospects for TD-NIRS in the near future are briefly described.
Collapse
|
4
|
He L, Baker WB, Milej D, Kavuri VC, Mesquita RC, Busch DR, Abramson K, Jiang JY, Diop M, St. Lawrence K, Amendolia O, Quattrone F, Balu R, Kofke WA, Yodh AG. Noninvasive continuous optical monitoring of absolute cerebral blood flow in critically ill adults. NEUROPHOTONICS 2018; 5:045006. [PMID: 30480039 PMCID: PMC6251207 DOI: 10.1117/1.nph.5.4.045006] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2018] [Accepted: 10/29/2018] [Indexed: 05/18/2023]
Abstract
We investigate a scheme for noninvasive continuous monitoring of absolute cerebral blood flow (CBF) in adult human patients based on a combination of time-resolved dynamic contrast-enhanced near-infrared spectroscopy (DCE-NIRS) and diffuse correlation spectroscopy (DCS) with semi-infinite head model of photon propogation. Continuous CBF is obtained via calibration of the DCS blood flow index (BFI) with absolute CBF obtained by intermittent intravenous injections of the optical contrast agent indocyanine green. A calibration coefficient ( γ ) for the CBF is thus determined, permitting conversion of DCS BFI to absolute blood flow units at all other times. A study of patients with acute brain injury ( N = 7 ) is carried out to ascertain the stability of γ . The patient-averaged DCS calibration coefficient across multiple monitoring days and multiple patients was determined, and good agreement between the two calibration coefficients measured at different times during single monitoring days was found. The patient-averaged calibration coefficient of 1.24 × 10 9 ( mL / 100 g / min ) / ( cm 2 / s ) was applied to previously measured DCS BFI from similar brain-injured patients; in this case, absolute CBF was underestimated compared with XeCT, an effect we show is primarily due to use of semi-infinite homogeneous models of the head.
Collapse
Affiliation(s)
- Lian He
- University of Pennsylvania, Department of Physics and Astronomy, Philadelphia, Pennsylvania, United States
- Address all correspondence to: Lian He, E-mail:
| | - Wesley B. Baker
- University of Pennsylvania, Department of Physics and Astronomy, Philadelphia, Pennsylvania, United States
- University of Pennsylvania, Department of Anesthesiology and Critical Care, Perelman School of Medicine, Philadelphia, Pennsylvania, United States
| | - Daniel Milej
- Western University, Department of Medical Biophysics, London, Ontario, Canada
- Lawson Health Research Institute, Imaging Division, London, Ontario, Canada
| | - Venkaiah C. Kavuri
- University of Pennsylvania, Department of Physics and Astronomy, Philadelphia, Pennsylvania, United States
| | | | - David R. Busch
- University of Texas Southwestern, Department of Neurology and Neurotherapeutics, Dallas, Texas, United States
- University of Texas Southwestern, Department of Anesthesiology and Pain Management, Dallas, Texas, United States
| | - Kenneth Abramson
- University of Pennsylvania, Department of Physics and Astronomy, Philadelphia, Pennsylvania, United States
| | - Jane Y. Jiang
- University of Pennsylvania, Department of Physics and Astronomy, Philadelphia, Pennsylvania, United States
| | - Mamadou Diop
- Western University, Department of Medical Biophysics, London, Ontario, Canada
- Lawson Health Research Institute, Imaging Division, London, Ontario, Canada
| | - Keith St. Lawrence
- Western University, Department of Medical Biophysics, London, Ontario, Canada
- Lawson Health Research Institute, Imaging Division, London, Ontario, Canada
| | - Olivia Amendolia
- University of Pennsylvania, Department of Neurosurgery, Perelman School of Medicine, Philadelphia, Pennsylvania, United States
| | - Francis Quattrone
- University of Pennsylvania, Department of Neurosurgery, Perelman School of Medicine, Philadelphia, Pennsylvania, United States
| | - Ramani Balu
- University of Pennsylvania, Department of Neurosurgery, Perelman School of Medicine, Philadelphia, Pennsylvania, United States
- University of Pennsylvania, Department of Neurology, Perelman School of Medicine, Philadelphia, Pennsylvania, United States
| | - W. Andrew Kofke
- University of Pennsylvania, Department of Anesthesiology and Critical Care, Perelman School of Medicine, Philadelphia, Pennsylvania, United States
- University of Pennsylvania, Department of Neurosurgery, Perelman School of Medicine, Philadelphia, Pennsylvania, United States
| | - Arjun G. Yodh
- University of Pennsylvania, Department of Physics and Astronomy, Philadelphia, Pennsylvania, United States
- University of Pennsylvania, Department of Anesthesiology and Critical Care, Perelman School of Medicine, Philadelphia, Pennsylvania, United States
| |
Collapse
|
5
|
Liu Y, Ghassemi P, Depkon A, Iacono MI, Lin J, Mendoza G, Wang J, Tang Q, Chen Y, Pfefer TJ. Biomimetic 3D-printed neurovascular phantoms for near-infrared fluorescence imaging. BIOMEDICAL OPTICS EXPRESS 2018; 9:2810-2824. [PMID: 30258692 PMCID: PMC6154206 DOI: 10.1364/boe.9.002810] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2018] [Revised: 05/17/2018] [Accepted: 05/18/2018] [Indexed: 05/03/2023]
Abstract
Emerging three-dimensional (3D) printing technology enables the fabrication of optically realistic and morphologically complex tissue-simulating phantoms for the development and evaluation of novel optical imaging products. In this study, we assess the potential to print image-defined neurovascular phantoms with patent channels for contrast-enhanced near-infrared fluorescence (NIRF) imaging. An anatomical map defined from clinical magnetic resonance imaging (MRI) was segmented and processed into files suitable for printing a forebrain vessel network in rectangular and curved-surface biomimetic phantoms. Methods for effectively cleaning samples with complex vasculature were determined. A final set of phantoms were imaged with a custom NIRF system at 785 nm excitation using two NIRF contrast agents. In addition to demonstrating the strong potential of 3D printing for creating highly realistic, patient-specific biophotonic phantoms, our work provides insight into optimal methods for accomplishing this goal and elucidates current limitations of this approach.
Collapse
Affiliation(s)
- Yi Liu
- Department of Bioengineering, University of Maryland, Silver Spring, MD, USA
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, USA
- Authors contributed equally to this work
| | - Pejhman Ghassemi
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, USA
- Authors contributed equally to this work
| | - Andrew Depkon
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, USA
- Marquette University, Milwaukee, WI, USA
| | - Maria Ida Iacono
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, USA
| | - Jonathan Lin
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, USA
| | - Gonzalo Mendoza
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, USA
| | - Jianting Wang
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, USA
| | - Qinggong Tang
- Department of Bioengineering, University of Maryland, Silver Spring, MD, USA
| | - Yu Chen
- Department of Bioengineering, University of Maryland, Silver Spring, MD, USA
| | - T Joshua Pfefer
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, USA
| |
Collapse
|
6
|
Confirmation of brain death using optical methods based on tracking of an optical contrast agent: assessment of diagnostic feasibility. Sci Rep 2018; 8:7332. [PMID: 29743483 PMCID: PMC5943525 DOI: 10.1038/s41598-018-25351-6] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Accepted: 04/09/2018] [Indexed: 11/20/2022] Open
Abstract
We aimed to determine whether optical methods based on bolus tracking of an optical contrast agent are useful for the confirmation of cerebral circulation cessation in patients being evaluated for brain death. Different stages of cerebral perfusion disturbance were compared in three groups of subjects: controls, patients with posttraumatic cerebral edema, and patients with brain death. We used a time-resolved near-infrared spectroscopy setup and indocyanine green (ICG) as an intravascular flow tracer. Orthogonal partial least squares-discriminant analysis (OPLS-DA) was carried out to build statistical models allowing for group separation. Thirty of 37 subjects (81.1%) were classified correctly (8 of 9 control subjects, 88.9%; 13 of 15 patients with edema, 86.7%; and 9 of 13 patients with brain death, 69.2%; p < 0.0001). Depending on the combination of variables used in the OPLS-DA model, sensitivity, specificity, and accuracy were 66.7–92.9%, 81.8–92.9%, and 77.3–89.3%, respectively. The method was feasible and promising in the demanding intensive care unit environment. However, its accuracy did not reach the level required for brain death confirmation. The potential usefulness of the method may be improved by increasing the depth of light penetration, confirming its accuracy against other methods evaluating cerebral flow cessation, and developing absolute parameters for cerebral perfusion.
Collapse
|
7
|
Carbone NA, Iriarte DI, Pomarico JA. GPU accelerated Monte Carlo simulation of light propagation in inhomogeneous fluorescent turbid media: application to whole field CW imaging. Biomed Phys Eng Express 2017. [DOI: 10.1088/2057-1976/aa7b8f] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
8
|
Weigl W, Milej D, Janusek D, Wojtkiewicz S, Sawosz P, Kacprzak M, Gerega A, Maniewski R, Liebert A. Application of optical methods in the monitoring of traumatic brain injury: A review. J Cereb Blood Flow Metab 2016; 36:1825-1843. [PMID: 27604312 PMCID: PMC5094301 DOI: 10.1177/0271678x16667953] [Citation(s) in RCA: 49] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2016] [Revised: 06/28/2016] [Accepted: 07/18/2016] [Indexed: 01/19/2023]
Abstract
We present an overview of the wide range of potential applications of optical methods for monitoring traumatic brain injury. The MEDLINE database was electronically searched with the following search terms: "traumatic brain injury," "head injury," or "head trauma," and "optical methods," "NIRS," "near-infrared spectroscopy," "cerebral oxygenation," or "cerebral oximetry." Original reports concerning human subjects published from January 1980 to June 2015 in English were analyzed. Fifty-four studies met our inclusion criteria. Optical methods have been tested for detection of intracranial lesions, monitoring brain oxygenation, assessment of brain perfusion, and evaluation of cerebral autoregulation or intracellular metabolic processes in the brain. Some studies have also examined the applicability of optical methods during the recovery phase of traumatic brain injury . The limitations of currently available optical methods and promising directions of future development are described in this review. Considering the outstanding technical challenges, the limited number of patients studied, and the mixed results and opinions gathered from other reviews on this subject, we believe that optical methods must remain primarily research tools for the present. More studies are needed to gain confidence in the use of these techniques for neuromonitoring of traumatic brain injury patients.
Collapse
Affiliation(s)
- Wojciech Weigl
- Department of Surgical Sciences/Anaesthesiology and Intensive Care, Uppsala University, Akademiska Hospital, Uppsala, Sweden
| | - Daniel Milej
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
| | - Dariusz Janusek
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
| | - Stanisław Wojtkiewicz
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
| | - Piotr Sawosz
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
| | - Michał Kacprzak
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
| | - Anna Gerega
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
| | - Roman Maniewski
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
| | - Adam Liebert
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
| |
Collapse
|
9
|
Milej D, Janusek D, Gerega A, Wojtkiewicz S, Sawosz P, Treszczanowicz J, Weigl W, Liebert A. Optimization of the method for assessment of brain perfusion in humans using contrast-enhanced reflectometry: multidistance time-resolved measurements. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:106013. [PMID: 26509415 DOI: 10.1117/1.jbo.20.10.106013] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2015] [Accepted: 10/06/2015] [Indexed: 05/24/2023]
Abstract
The aim of the study was to determine optimal measurement conditions for assessment of brain perfusion with the use of optical contrast agent and time-resolved diffuse reflectometry in the near-infrared wavelength range. The source-detector separation at which the distribution of time of flights (DTOF) of photons provided useful information on the inflow of the contrast agent to the intracerebral brain tissue compartments was determined. Series of Monte Carlo simulations was performed in which the inflow and washout of the dye in extra- and intracerebral tissue compartments was modeled and the DTOFs were obtained at different source-detector separations. Furthermore, tests on diffuse phantoms were carried out using a time-resolved setup allowing the measurement of DTOFs at 16 source-detector separations. Finally, the setup was applied in experiments carried out on the heads of adult volunteers during intravenous injection of indocyanine green. Analysis of statistical moments of the measured DTOFs showed that the source-detector separation of 6 cm is recommended for monitoring of inflow of optical contrast to the intracerebral brain tissue compartments with the use of continuous wave reflectometry, whereas the separation of 4 cm is enough when the higher-order moments of DTOFs are available.
Collapse
Affiliation(s)
- Daniel Milej
- Polish Academy of Sciences, Nalecz Institute of Biocybernetics and Biomedical Engineering, 4Ks. Trojdena Street 02-109 Warsaw, Poland
| | - Dariusz Janusek
- Polish Academy of Sciences, Nalecz Institute of Biocybernetics and Biomedical Engineering, 4Ks. Trojdena Street 02-109 Warsaw, Poland
| | - Anna Gerega
- Polish Academy of Sciences, Nalecz Institute of Biocybernetics and Biomedical Engineering, 4Ks. Trojdena Street 02-109 Warsaw, Poland
| | - Stanislaw Wojtkiewicz
- Polish Academy of Sciences, Nalecz Institute of Biocybernetics and Biomedical Engineering, 4Ks. Trojdena Street 02-109 Warsaw, Poland
| | - Piotr Sawosz
- Polish Academy of Sciences, Nalecz Institute of Biocybernetics and Biomedical Engineering, 4Ks. Trojdena Street 02-109 Warsaw, Poland
| | - Joanna Treszczanowicz
- Warsaw Praski Hospital, Department of Intensive Care and Anesthesiology, 67 Al. Solidarnosci Street, 03-401 Warsaw, Poland
| | - Wojciech Weigl
- Warsaw Praski Hospital, Department of Intensive Care and Anesthesiology, 67 Al. Solidarnosci Street, 03-401 Warsaw, PolandcUppsala University, Department of Surgical Sciences/Anesthesiology and Intensive Care, 751 85 Uppsala, Sweden
| | - Adam Liebert
- Polish Academy of Sciences, Nalecz Institute of Biocybernetics and Biomedical Engineering, 4Ks. Trojdena Street 02-109 Warsaw, Poland
| |
Collapse
|
10
|
Liebert A, Milej D, Weigl W, Gerega A, Kacprzak M, Maniewski R. Fluorescence-based method for assessment of blood-brain barrier disruption. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2013:3040-2. [PMID: 24110368 DOI: 10.1109/embc.2013.6610181] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
We report on a fluorescence-based optical method for assessment of blood-brain barrier in humans. The technique is based on monitoring of fluorescence light excited in the dye circulating in the brain. Measurements were carried out in healthy volunteers and in patients with disruption of the blood-brain barrier with the use of time-resolved method during inflow and washout of indocyanine green after its intravenous injection. We show large differences in the fluorescence signals - in healthy subjects a fast washout of the dye can be observed whereas in patients the washout is significantly prolonged. We conclude that the monitoring of the fluorescence signals during injection of exogenous optical contrast agent can be used for the assessment of the condition of blood-brain barrier at the bedside. The technique may be of benefit for diagnosis of the patients suffering from damage of the blood-brain barrier and in monitoring of therapies used in such patients.
Collapse
|
11
|
Li Z, Baker WB, Parthasarathy AB, Ko TS, Wang D, Schenkel S, Durduran T, Li G, Yodh AG. Calibration of diffuse correlation spectroscopy blood flow index with venous-occlusion diffuse optical spectroscopy in skeletal muscle. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:125005. [PMID: 26720870 PMCID: PMC4688416 DOI: 10.1117/1.jbo.20.12.125005] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2015] [Accepted: 11/17/2015] [Indexed: 05/09/2023]
Abstract
We investigate and assess the utility of a simple scheme for continuous absolute blood flow monitoring based on diffuse correlation spectroscopy (DCS). The scheme calibrates DCS using venous-occlusion diffuse optical spectroscopy (VO-DOS) measurements of arm muscle tissue at a single time-point. A calibration coefficient (γ) for the arm is determined, permitting conversion of DCS blood flow indices to absolute blood flow units, and a study of healthy adults (N=10) is carried out to ascertain the variability of γ. The average DCS calibration coefficient for the right (i.e., dominant) arm was γ=(1.24±0.15)×10(8) (mL·100 mL(−1)·min(−1))/(cm(2)/s). However, variability can be significant and is apparent in our site-to-site and day-to-day repeated measurements. The peak hyperemic blood flow overshoot relative to baseline resting flow was also studied following arm-cuff ischemia; excellent agreement between VO-DOS and DCS was found (R(2)=0.95, slope=0.94±0.07, mean difference=−0.10±0.45). Finally, we show that incorporation of subject-specific absolute optical properties significantly improves blood flow calibration accuracy.
Collapse
Affiliation(s)
- Zhe Li
- University of Pennsylvania, Department of Physics & Astronomy, 209 South 33rd Street, Philadelphia, Pennsylvania 19104, United States
- Tianjin University, School of Precision Instrument and Opto-Electronics Engineering, Tianjin 300072, China
- Tianjin University, State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin 300072, China
- Address all correspondence to: Zhe Li, E-mail:
| | - Wesley B. Baker
- University of Pennsylvania, Department of Physics & Astronomy, 209 South 33rd Street, Philadelphia, Pennsylvania 19104, United States
| | - Ashwin B. Parthasarathy
- University of Pennsylvania, Department of Physics & Astronomy, 209 South 33rd Street, Philadelphia, Pennsylvania 19104, United States
| | - Tiffany S. Ko
- University of Pennsylvania, Department of Bioengineering, 210 South 33rd Street, Philadelphia, Pennsylvania 19104, United States
| | - Detian Wang
- University of Pennsylvania, Department of Physics & Astronomy, 209 South 33rd Street, Philadelphia, Pennsylvania 19104, United States
- Institute of Fluid Physics, Mianyang 621000, China
| | - Steven Schenkel
- University of Pennsylvania, Department of Physics & Astronomy, 209 South 33rd Street, Philadelphia, Pennsylvania 19104, United States
| | - Turgut Durduran
- ICFO-Institut de Ciéncies Fotóniques, Mediterranean Technology Park, 08860 Castelldefels (Barcelona), Spain
| | - Gang Li
- Tianjin University, School of Precision Instrument and Opto-Electronics Engineering, Tianjin 300072, China
- Tianjin University, State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin 300072, China
| | - Arjun G. Yodh
- University of Pennsylvania, Department of Physics & Astronomy, 209 South 33rd Street, Philadelphia, Pennsylvania 19104, United States
| |
Collapse
|
12
|
Milej D, Kruczkowski M, Kacprzak M, Sawosz P, Maniewski R, Liebert A. Estimation of light detection efficiency for different light guides used in time-resolved near-infrared spectroscopy. Biocybern Biomed Eng 2015. [DOI: 10.1016/j.bbe.2015.05.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
13
|
Toczylowska B, Zieminska E, Goch G, Milej D, Gerega A, Liebert A. Neurotoxic effects of indocyanine green -cerebellar granule cell culture viability study. BIOMEDICAL OPTICS EXPRESS 2014; 5:800-16. [PMID: 24688815 PMCID: PMC3959834 DOI: 10.1364/boe.5.000800] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2013] [Revised: 02/08/2014] [Accepted: 02/10/2014] [Indexed: 05/05/2023]
Abstract
The aim of this study was to examine neurotoxicity indocyanine green (ICG). We assessed viability of primary cerebellar granule cell culture (CGC) exposed to ICG to test two mechanisms that could be the first triggers causing neuronal toxicity: imbalance in calcium homeostasis and the degree of oligomerization of ICG molecules. We have observed this imbalance in CGC after exposure to 75-125μΜ ICG and dose and application sequence dependent protective effect of Gadovist on surviving neurons in vitro when used with ICG. Spectroscopic studies suggest the major cause of toxicity of the ICG is connected with oligomers formation. ICG at concentration of 25 μM (which is about 4 times higher than the highest concentration of ICG in the brain applied in in-vivo human studies) is not neurotoxic in the cell culture.
Collapse
Affiliation(s)
- Beata Toczylowska
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, 4 Trojdena Str. 02-109 Warsaw, Poland
- Institute of Biochemistry and Biophysics, Polish Academy of Sciences, 5A Pawinskiego Str., 02-106 Warsaw, Poland
| | - Elzbieta Zieminska
- Mossakowski Medical Research Centre, Polish Academy of Sciences, 5 Pawinskiego Str., 02-106 Warsaw, Poland
| | - Grazyna Goch
- Institute of Biochemistry and Biophysics, Polish Academy of Sciences, 5A Pawinskiego Str., 02-106 Warsaw, Poland
| | - Daniel Milej
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, 4 Trojdena Str. 02-109 Warsaw, Poland
| | - Anna Gerega
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, 4 Trojdena Str. 02-109 Warsaw, Poland
| | - Adam Liebert
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, 4 Trojdena Str. 02-109 Warsaw, Poland
| |
Collapse
|
14
|
Milej D, Gerega A, Wabnitz H, Liebert A. A Monte Carlo study of fluorescence generation probability in a two-layered tissue model. Phys Med Biol 2014; 59:1407-24. [DOI: 10.1088/0031-9155/59/6/1407] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
15
|
Weichelt C, Duscha P, Steinmeier R, Meyer T, Kuß J, Cimalla P, Kirsch M, Sobottka SB, Koch E, Schackert G, Morgenstern U. Quantitative fluorescence angiography for neurosurgical interventions. ACTA ACUST UNITED AC 2014; 58:269-79. [PMID: 23740655 DOI: 10.1515/bmt-2012-0078] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2013] [Accepted: 05/17/2013] [Indexed: 11/15/2022]
Abstract
Present methods for quantitative measurement of cerebral perfusion during neurosurgical operations require additional technology for measurement, data acquisition, and processing. This study used conventional fluorescence video angiography--as an established method to visualize blood flow in brain vessels--enhanced by a quantifying perfusion software tool. For these purposes, the fluorescence dye indocyanine green is given intravenously, and after activation by a near-infrared light source the fluorescence signal is recorded. Video data are analyzed by software algorithms to allow quantification of the blood flow. Additionally, perfusion is measured intraoperatively by a reference system. Furthermore, comparing reference measurements using a flow phantom were performed to verify the quantitative blood flow results of the software and to validate the software algorithm. Analysis of intraoperative video data provides characteristic biological parameters. These parameters were implemented in the special flow phantom for experimental validation of the developed software algorithms. Furthermore, various factors that influence the determination of perfusion parameters were analyzed by means of mathematical simulation. Comparing patient measurement, phantom experiment, and computer simulation under certain conditions (variable frame rate, vessel diameter, etc.), the results of the software algorithms are within the range of parameter accuracy of the reference methods. Therefore, the software algorithm for calculating cortical perfusion parameters from video data presents a helpful intraoperative tool without complex additional measurement technology.
Collapse
Affiliation(s)
- Claudia Weichelt
- Institute of Biomedical Engineering, Faculty of Electrical Engineering and Information Technology, Technische Universität Dresden, Dresden, Germany.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Torricelli A, Contini D, Pifferi A, Caffini M, Re R, Zucchelli L, Spinelli L. Time domain functional NIRS imaging for human brain mapping. Neuroimage 2014; 85 Pt 1:28-50. [DOI: 10.1016/j.neuroimage.2013.05.106] [Citation(s) in RCA: 294] [Impact Index Per Article: 26.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2013] [Revised: 04/25/2013] [Accepted: 05/21/2013] [Indexed: 02/02/2023] Open
|
17
|
Milej D, Kruczkowski M, Gerega A, Sawosz P, Maniewski R, Liebert A. An algorithm for assessment of inflow and washout of optical contrast agent to the brain by analysis of time-resolved diffuse reflectance and fluorescence signals. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2013; 2013:1919-22. [PMID: 24110088 DOI: 10.1109/embc.2013.6609901] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
In optical measurements of the brain oxygenation and perfusion the problem of contamination of the signals with the components related to the extracerebral tissues remains an obstacle limiting clinical applicability of the technique. In this paper we present an algorithm allowing for derivation of signals related to the changes in absorption in the intracerebral tissues based on analysis of time-resolved diffuse reflectance and fluorescence. The proposed method was validated in series of Monte Carlo simulations in which inflow and washout of an optical contrast agent into the two-layered human head model was considered. It was shown that the decomposed intracerebral component of the signal can be derived with uncertainty of about 5%. This result suggests that the method proposed can be applied in improved estimation of brain perfusion parameters based on the bolus-tracking technique.
Collapse
|
18
|
Weigl W, Milej D, Gerega A, Toczylowska B, Kacprzak M, Sawosz P, Botwicz M, Maniewski R, Mayzner-Zawadzka E, Liebert A. Assessment of cerebral perfusion in post-traumatic brain injury patients with the use of ICG-bolus tracking method. Neuroimage 2013; 85 Pt 1:555-65. [PMID: 23831529 DOI: 10.1016/j.neuroimage.2013.06.065] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2013] [Revised: 06/15/2013] [Accepted: 06/20/2013] [Indexed: 11/17/2022] Open
Abstract
The aim of this study was to verify the usefulness of the time-resolved optical method utilizing diffusely reflected photons and fluorescence signals combined with intravenous injection of indocyanine green (ICG) in the assessment of brain perfusion in post-traumatic brain injury patients. The distributions of times of flight (DTOFs) of diffusely reflected photons were acquired together with the distributions of times of arrival (DTAs) of fluorescence photons. The data analysis methodology was based on the observation of delays between the signals of statistical moments (number of photons, mean time of flight and variance) of DTOFs and DTAs related to the inflow of ICG to the extra- and intracerebral tissue compartments. Eleven patients with brain hematoma, 15 patients with brain edema and a group of 9 healthy subjects were included in this study. Statistically significant differences between parameters obtained in healthy subjects and patients with brain hematoma and brain edema were observed. The best optical parameter to differentiate patients and control group was variance of the DTOFs or DTAs. Results of the study suggest that time-resolved optical monitoring of inflow of the ICG seems to be a promising tool for detecting cerebral perfusion insufficiencies in critically ill patients.
Collapse
Affiliation(s)
- W Weigl
- Medical University of Warsaw, I Department of Anesthesiology and Intensive Care, Warsaw, Poland; Warsaw Praski Hospital, Department of Intensive Care and Anesthesiology, Warsaw, Poland.
| | | | | | | | | | | | | | | | | | | |
Collapse
|