1
|
Jia SB, Shamsabadi R, Mogheiseh L, Baghani HR. Assessment of secondary cancer risks within non-target organs during proton therapy for lung cancer: A Monte Carlo study. Appl Radiat Isot 2024; 214:111532. [PMID: 39340980 DOI: 10.1016/j.apradiso.2024.111532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 07/29/2024] [Accepted: 09/24/2024] [Indexed: 09/30/2024]
Abstract
Proton therapy is a rapidly progressing modality with a significant impact on lung cancer treatment. However, there are concerns about the subsequent effects of secondary radiation in out-of-field organs. Thus, the present study aimed to evaluate the risk of subsequent secondary cancers within non-target organs during proton therapy for lung cancer. A Monte Carlo model of the International Commission on Radiological Protection (ICRP) 110 male phantom was employed to calculate the absorbed dose associated with secondary photons and neutrons within out-of-field organs for different tumor locations. The risk of induced secondary cancers was then estimated using the Biological Effects of Ionizing Radiation Committee (BEIR) VII and National Council on Radiation Protection and Measurements (NCRP) 116 risk models. Organs close to the tumor, such as the heart, esophagus, thymus, and liver, received the highest equivalent doses. The calculated equivalent doses increased as the tumor depth increased from 4-8 cm to 12-16 cm. The contribution of neutrons to the total equivalent dose was dominant (up to 90%) in most of the organs studied. The calculated risks of secondary cancers were higher in the liver and esophagus compared with other organs when using the BEIR risk model. The maximum risk value was obtained for the left lung when the NCRP 116 risk model was used. Furthermore, the estimated risks of secondary malignancies increased with the tumor depth using both risk models. The calculated risks of radiation-induced secondary cancers were relatively lower than the baseline cancer risks. However, extra attention is warranted to minimize subsequent secondary cancers after proton therapy for lung cancer.
Collapse
Affiliation(s)
| | - Reza Shamsabadi
- Physics Department, Hakim Sabzevari University, Sabzevar, Iran
| | - Leili Mogheiseh
- Physics Department, Hakim Sabzevari University, Sabzevar, Iran
| | | |
Collapse
|
2
|
Wang H, Yao B, Tang T, Gong M, Ma Y, Wu X, Zhu B. Racial/ethnic disparities in all-cause and cause-specific death among children with malignant central nervous system tumours: a registry-based cohort retrospective analysis. EClinicalMedicine 2024; 76:102816. [PMID: 39290638 PMCID: PMC11405826 DOI: 10.1016/j.eclinm.2024.102816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2024] [Revised: 08/16/2024] [Accepted: 08/21/2024] [Indexed: 09/19/2024] Open
Abstract
Background It is generally recognized that there is unequal mortality in childhood central nervous system (CNS) malignancy in the United States (US), but little is known about the trends and contributors of racial/ethnic disparities in death. We assessed the trends of racial/ethnic disparities in all-cause and cause-specific death, and the contributions of tumour, treatment and socioeconomic factors to this disparity. Methods This registry-based cohort study included children (aged ≤19 years) diagnosed with malignant CNS tumours, using data from the US population-based cancer registry in the Surveillance, Epidemiology, and End Results (SEER) Program. The clinical outcomes were all-cause and cause-specific death for each racial/ethnic group (White, Black, Hispanic, non-Hispanic Asian/Pacific Islander [API], and non-Hispanic American Indian/Alaska Native [AI/AN] children). We quantified absolute disparities using absolute rate difference in 5-year cumulative incidence of death. Cox proportion risk models were used to estimate the relative racial/ethnic disparities, and the contribution of factors to disparities in death. Findings In this study, data from 14,510 children with malignant CNS tumours (mean [SD] age, 8.5 [5.7]; 7988 [55.1%] male) were analysed. Overall, the cumulative incidence of death from CNS tumours across four racial/ethnic groups decreased from 2001 to 2020. Black patients had the highest risk of death from all causes and CNS tumours between 2001 and 2020, with adjusted hazard ratios (HR) of 1.52 (1.38-1.68) and 1.47 (1.31-1.64), respectively. The absolute disparity in all-cause death between Hispanic and White patients increased slightly (from 8.2 percentage points [ppt] to 9.4 ppt), and the relative disparity in death from CNS tumours increased from 1.33 (1.15-1.55) in 2001-2005 to 1.78 (1.44-2.20) in 2016-2020. The absolute disparities in death from CNS tumours between Black and White patients (from 11.8 ppt to 4.3 ppt) and between API and White patients (from 10.1 ppt to 5.1 ppt) decreased from 2001-2005 to 2011-2015. Interpretation Race/ethnicity disparities in death from CNS tumours among childhood malignant CNS tumours had reduced from 2001 to 2020, and quantifying the contribution of factors to this disparity in death could provide a basis for decreasing mortality among racial/ethnic minority patients. Funding Shenyang Young and Middle-aged Science and Technology Innovation Talent Support Program.
Collapse
Affiliation(s)
- Hongying Wang
- Department of Cancer Prevention and Treatment, Cancer Hospital of China Medical University/Liaoning Cancer Hospital & Institute, Shenyang, Liaoning Province, China
| | - Bing Yao
- Department of Neurosurgery, Cancer Hospital of China Medical University/Liaoning Cancer Hospital & Institute, Shenyang, Liaoning Province, China
| | - Tao Tang
- Department of Neurosurgery, Cancer Hospital of China Medical University/Liaoning Cancer Hospital & Institute, Shenyang, Liaoning Province, China
| | - Meixi Gong
- Department of Cancer Prevention and Treatment, Cancer Hospital of China Medical University/Liaoning Cancer Hospital & Institute, Shenyang, Liaoning Province, China
| | - Yuansen Ma
- Department of Cancer Prevention and Treatment, Cancer Hospital of China Medical University/Liaoning Cancer Hospital & Institute, Shenyang, Liaoning Province, China
| | - Xiaomei Wu
- Department of Clinical Epidemiology and Centre of Evidence Based Medicine, The First Hospital of China Medical University, Shenyang, Liaoning Province, China
| | - Bo Zhu
- Department of Cancer Prevention and Treatment, Cancer Hospital of China Medical University/Liaoning Cancer Hospital & Institute, Shenyang, Liaoning Province, China
| |
Collapse
|
3
|
Stokkevåg CH, Journy N, Vogelius IR, Howell RM, Hodgson D, Bentzen SM. Radiation Therapy Technology Advances and Mitigation of Subsequent Neoplasms in Childhood Cancer Survivors. Int J Radiat Oncol Biol Phys 2024; 119:681-696. [PMID: 38430101 DOI: 10.1016/j.ijrobp.2024.01.206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 12/17/2023] [Accepted: 01/13/2024] [Indexed: 03/03/2024]
Abstract
PURPOSE In this Pediatric Normal Tissue Effects in the Clinic (PENTEC) vision paper, challenges and opportunities in the assessment of subsequent neoplasms (SNs) from radiation therapy (RT) are presented and discussed in the context of technology advancement. METHODS AND MATERIALS The paper discusses the current knowledge of SN risks associated with historic, contemporary, and future RT technologies. Opportunities for research and SN mitigation strategies in pediatric patients with cancer are reviewed. RESULTS Present experience with radiation carcinogenesis is from populations exposed during widely different scenarios. Knowledge gaps exist within clinical cohorts and follow-up; dose-response and volume effects; dose-rate and fractionation effects; radiation quality and proton/particle therapy; age considerations; susceptibility of specific tissues; and risks related to genetic predisposition. The biological mechanisms associated with local and patient-level risks are largely unknown. CONCLUSIONS Future cancer care is expected to involve several available RT technologies, necessitating evidence and strategies to assess the performance of competing treatments. It is essential to maximize the utilization of existing follow-up while planning for prospective data collection, including standardized registration of individual treatment information with linkage across patient databases.
Collapse
Affiliation(s)
- Camilla H Stokkevåg
- Department of Oncology and Medical Physics, Haukeland University Hospital, Bergen, Norway; Department of Physics and Technology, University of Bergen, Bergen, Norway.
| | - Neige Journy
- French National Institute of Health and Medical Research (INSERM) Unit 1018, Centre for Research in Epidemiology and Population Health, Paris Saclay University, Gustave Roussy, Villejuif, France
| | - Ivan R Vogelius
- Department of Clinical Oncology, Centre for Cancer and Organ Diseases and University of Copenhagen, Copenhagen, Denmark
| | - Rebecca M Howell
- Department of Radiation Oncology, MD Anderson Cancer Center, Houston, Texas
| | - David Hodgson
- Department of Radiation Oncology, University of Toronto, Princess Margaret Cancer Center, Toronto, Ontario, Canada
| | - Søren M Bentzen
- Department of Epidemiology and Public Health, University of Maryland, Baltimore, Maryland
| |
Collapse
|
4
|
Hoeltgen L, Meixner E, Hoegen-Saßmannshausen P, Kim JY, Deng M, Seidensaal K, Held T, Herfarth K, Haberer T, Debus J, Mairani A, Harrabi S, Tessonnier T. Helium Ion Therapy for Advanced Juvenile Nasopharyngeal Angiofibroma. Cancers (Basel) 2024; 16:1993. [PMID: 38893114 PMCID: PMC11171253 DOI: 10.3390/cancers16111993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2024] [Revised: 05/17/2024] [Accepted: 05/18/2024] [Indexed: 06/21/2024] Open
Abstract
Helium ion therapy (HRT) is a promising modality for the treatment of pediatric tumors and those located close to critical structures due to the favorable biophysical properties of helium ions. This in silico study aimed to explore the potential benefits of HRT in advanced juvenile nasopharyngeal angiofibroma (JNA) compared to proton therapy (PRT). We assessed 11 consecutive patients previously treated with PRT for JNA in a definitive or postoperative setting with a relative biological effectiveness (RBE) weighted dose of 45 Gy (RBE) in 25 fractions at the Heidelberg Ion-Beam Therapy Center. HRT plans were designed retrospectively for dosimetric comparisons and risk assessments of radiation-induced complications. HRT led to enhanced target coverage in all patients, along with sparing of critical organs at risk, including a reduction in the brain integral dose by approximately 27%. In terms of estimated risks of radiation-induced complications, HRT led to a reduction in ocular toxicity, cataract development, xerostomia, tinnitus, alopecia and delayed recall. Similarly, HRT led to reduced estimated risks of radiation-induced secondary neoplasms, with a mean excess absolute risk reduction of approximately 30% for secondary CNS malignancies. HRT is a promising modality for advanced JNA, with the potential for enhanced sparing of healthy tissue and thus reduced radiation-induced acute and long-term complications.
Collapse
Affiliation(s)
- Line Hoeltgen
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany; (L.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
| | - Eva Meixner
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany; (L.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
| | - Philipp Hoegen-Saßmannshausen
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany; (L.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
| | - Ji-Young Kim
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany; (L.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
| | - Maximilian Deng
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany; (L.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
| | - Katharina Seidensaal
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany; (L.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
| | - Thomas Held
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany; (L.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
| | - Klaus Herfarth
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany; (L.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
| | - Thomas Haberer
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Jürgen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany; (L.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
- Partner Site, German Cancer Consortium (DKTK), 69120 Heidelberg, Germany
| | - Andrea Mairani
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
- Centro Nazionale di Adroterapia Oncologica (CNAO), Medical Physics Department, 27100 Pavia, Italy
| | - Semi Harrabi
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany; (L.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
| | - Thomas Tessonnier
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
| |
Collapse
|
5
|
Hoeltgen L, Tessonnier T, Meixner E, Hoegen P, Kim JY, Deng M, Seidensaal K, Held T, Herfarth K, Debus J, Harrabi S. Proton Therapy for Advanced Juvenile Nasopharyngeal Angiofibroma. Cancers (Basel) 2023; 15:5022. [PMID: 37894389 PMCID: PMC10605854 DOI: 10.3390/cancers15205022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 10/12/2023] [Accepted: 10/13/2023] [Indexed: 10/29/2023] Open
Abstract
PURPOSE To provide the first report on proton radiotherapy (PRT) in the management of advanced nasopharyngeal angiofibroma (JNA) and evaluate potential benefits compared to conformal photon therapy (XRT). METHODS We retrospectively reviewed 10 consecutive patients undergoing PRT for advanced JNA in a definitive or postoperative setting with a relative biological effectiveness weighted dose of 45 Gy in 25 fractions between 2012 and 2022 at the Heidelberg Ion Beam Therapy Center. Furthermore, dosimetric comparisons and risk estimations for short- and long-term radiation-induced complications between PRT plans and helical XRT plans were conducted. RESULTS PRT was well tolerated, with only low-grade acute toxicities (CTCAE I-II) being reported. The local control rate was 100% after a median follow-up of 27.0 (interquartile range 13.3-58.0) months. PRT resulted in considerable tumor shrinkage, leading to complete remission in five patients and bearing the potential to provide partial or complete symptom relief. Favorable dosimetric outcomes in critical brain substructures by the use of PRT translated into reduced estimated risks for neurocognitive impairment and radiation-induced CNS malignancies compared to XRT. CONCLUSIONS PRT is an effective treatment option for advanced JNA with minimal acute morbidity and the potential for reduced radiation-induced long-term complications.
Collapse
Affiliation(s)
- Line Hoeltgen
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany (S.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany;
- National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Thomas Tessonnier
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany;
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
| | - Eva Meixner
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany (S.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany;
- National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Philipp Hoegen
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany (S.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany;
- National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
| | - Ji-Young Kim
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany (S.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany;
- National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Maximilian Deng
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany (S.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany;
- National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Katharina Seidensaal
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany (S.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany;
- National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Thomas Held
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany (S.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany;
- National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Klaus Herfarth
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany (S.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany;
- National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Juergen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany (S.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany;
- National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
- German Cancer Consortium (DKTK), Partner Site, 69120 Heidelberg, Germany
| | - Semi Harrabi
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany (S.H.)
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany;
- National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany
| |
Collapse
|
6
|
Dell'Oro M, Wilson P, Short M, Peukert D, Bezak E. Modelling the influence of radiosensitivity on development of second primary cancer in out-of-field organs following proton therapy for paediatric cranial cancer. Br J Radiol 2023; 96:20230161. [PMID: 37660473 PMCID: PMC10546440 DOI: 10.1259/bjr.20230161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 06/16/2023] [Accepted: 07/19/2023] [Indexed: 09/05/2023] Open
Abstract
OBJECTIVE Radiobiological modelling the risks of second primary cancer (SPC) after proton therapy (PT) for childhood cranial cancer remains largely unknown. Organ-specific dose-response risk factors such as radiosensitivity require exploration. This study compared the influence of radiosensitivity data (slope of βEAR) on children's lifetime attributable risks (LAR) of SPC development in out-of-field organs following cranial scattering and scanning PT. METHODS Out-of-field radiosensitivity parameter estimates for organs (α/β and βEAR) were sourced from literature. Physical distances for 13 out-of-field organs were measured and input into Schneider's SPC model. Sensitivity analyses were performed as a function of radiosensitivity (α/β of 1-10 Gy) and initial slope (βEAR) from Japanese/UK data to estimate the influence on the risk of radiation-induced SPC following scattering and scanning PT. RESULTS Models showed similar LAR of SPC estimates for age and sex-matched paediatric phantoms, however, for breast there was a significant increase using Japanese βEAR data. For most organs, scattering PT demonstrated a larger risk of LAR for SPC which increased with α/β. CONCLUSION Breast tissue exhibited the highest susceptibility in calculated LAR risk, demonstrating the importance for accurate data input when estimating LAR of SPC. ADVANCES IN KNOWLEDGE The findings of this study demonstrated younger female patients undergoing cranial proton therapy have a higher risk of developing second primary cancer of the breast tissue. Long-term multicenter registries are important to improve predictive radiobiological modelling studies of side effects.
Collapse
Affiliation(s)
| | | | - Michala Short
- Cancer Research Institute, University of South Australia, Adelaide, Australia
| | - Dylan Peukert
- ARC Training Centre for Integrated Operations for Complex Resources, University of Adelaide, Adelaide, Australia
| | | |
Collapse
|
7
|
Lim AE, Hurley R, Slim MAM, Melia L. A Narrative Review of Flutamide in Juvenile Nasopharyngeal Angiofibroma. Indian J Otolaryngol Head Neck Surg 2023; 75:2707-2712. [PMID: 37636686 PMCID: PMC10447844 DOI: 10.1007/s12070-023-03581-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Accepted: 02/16/2023] [Indexed: 08/29/2023] Open
Abstract
The detection of androgen receptors within Juvenile Nasopharyngeal Angiofibroma (JNA) has prompted investigation of the role of Flutamide. The aim of this review is to evaluate Flutamide as a possible neo-adjuvant treatment for JNA. Literature searches were conducted using MEDLINE, EMBASE and Web of Science. The Joanna Briggs Institute (JBI) checklist was used to assess risk of bias. The Oxford Centre of Evidence-Based Medicine (OCEBM) Levels of Evidence was used to stratify the evidence level. Literature searches were conducted using MEDLINE, EMBASE and Web of Science. Flutamide as neo-adjuvant treatment potentially causes a reduction in JNA tumor volume by ≥ 25%. Based on the current limited evidence, Flutamide has a limited role in JNA management and further research is required. Its utilization should only follow discussion with the patient, their families, and within the multidisciplinary team.
Collapse
Affiliation(s)
- Alison Emily Lim
- Department of Ear, Nose and Throat, Queen Elizabeth University Hospital, 1345 Govan Rd, Glasgow, G51 4TF UK
| | - Rhona Hurley
- Department of Ear, Nose and Throat, Queen Elizabeth University Hospital, 1345 Govan Rd, Glasgow, G51 4TF UK
| | - Mohd Afiq Mohd Slim
- Department of Ear, Nose and Throat, Queen Elizabeth University Hospital, 1345 Govan Rd, Glasgow, G51 4TF UK
| | - Louise Melia
- Department of Ear, Nose and Throat, Queen Elizabeth University Hospital, 1345 Govan Rd, Glasgow, G51 4TF UK
| |
Collapse
|
8
|
Toussaint L, Indelicato DJ, Muren LP, Stokkevåg CH. Risk of second primary cancer from proton arc therapy of pediatric brain tumors. Phys Imaging Radiat Oncol 2023; 27:100480. [PMID: 37655121 PMCID: PMC10465935 DOI: 10.1016/j.phro.2023.100480] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 07/31/2023] [Accepted: 08/02/2023] [Indexed: 09/02/2023] Open
Abstract
Proton arc therapy (PAT) is currently explored for clinical implementation, despite its associated low-dose bath. This study therefore aimed at evaluating the risk of radiation-induced second primary cancer (SPC) for PAT in pediatric brain tumor patients. Two brain-specific models for SPC induction were applied in five cases to compare volumetric modulated arc therapy (VMAT), intensity modulated proton therapy (IMPT) and PAT surrogate plans. The PAT integral dose was reduced by a median of 29% compared to VMAT, and 17% compared to IMPT. For both models, the estimated SPC risks were consistently the lowest for PAT.
Collapse
Affiliation(s)
- Laura Toussaint
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Daniel J Indelicato
- Department of Radiation Oncology, University of Florida Health Proton Therapy Institute, Jacksonville, FL, USA
| | - Ludvig P Muren
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Camilla H Stokkevåg
- Department of Oncology and Medical Physics, Haukeland University Hospital, Bergen, Norway
| |
Collapse
|
9
|
Knežević Ž, Stolarczyk L, Ambrožová I, Caballero-Pacheco MÁ, Davídková M, De Saint-Hubert M, Domingo C, Jeleń K, Kopeć R, Krzempek D, Majer M, Miljanić S, Mojżeszek N, Romero-Expósito M, Martínez-Rovira I, Harrison RM, Olko P. Out-of-Field Doses Produced by a Proton Scanning Beam Inside Pediatric Anthropomorphic Phantoms and Their Comparison With Different Photon Modalities. Front Oncol 2022; 12:904563. [PMID: 35957900 PMCID: PMC9361051 DOI: 10.3389/fonc.2022.904563] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Accepted: 06/15/2022] [Indexed: 11/23/2022] Open
Abstract
Since 2010, EURADOS Working Group 9 (Radiation Dosimetry in Radiotherapy) has been involved in the investigation of secondary and scattered radiation doses in X-ray and proton therapy, especially in the case of pediatric patients. The main goal of this paper is to analyze and compare out-of-field neutron and non-neutron organ doses inside 5- and 10-year-old pediatric anthropomorphic phantoms for the treatment of a 5-cm-diameter brain tumor. Proton irradiations were carried out at the Cyclotron Centre Bronowice in IFJ PAN Krakow Poland using a pencil beam scanning technique (PBS) at a gantry with a dedicated scanning nozzle (IBA Proton Therapy System, Proteus 235). Thermoluminescent and radiophotoluminescent dosimeters were used for non-neutron dose measurements while secondary neutrons were measured with track-etched detectors. Out-of-field doses measured using intensity-modulated proton therapy (IMPT) were compared with previous measurements performed within a WG9 for three different photon radiotherapy techniques: 1) intensity-modulated radiation therapy (IMRT), 2) three-dimensional conformal radiation therapy (3D CDRT) performed on a Varian Clinac 2300 linear accelerator (LINAC) in the Centre of Oncology, Krakow, Poland, and 3) Gamma Knife surgery performed on the Leksell Gamma Knife (GK) at the University Hospital Centre Zagreb, Croatia. Phantoms and detectors used in experiments as well as the target location were the same for both photon and proton modalities. The total organ dose equivalent expressed as the sum of neutron and non-neutron components in IMPT was found to be significantly lower (two to three orders of magnitude) in comparison with the different photon radiotherapy techniques for the same delivered tumor dose. For IMPT, neutron doses are lower than non-neutron doses close to the target but become larger than non-neutron doses further away from the target. Results of WG9 studies have provided out-of-field dose levels required for an extensive set of radiotherapy techniques, including proton therapy, and involving a complete description of organ doses of pediatric patients. Such studies are needed for validating mathematical models and Monte Carlo simulation tools for out-of-field dosimetry which is essential for dedicated epidemiological studies which evaluate the risk of second cancers and other late effects for pediatric patients treated with radiotherapy.
Collapse
Affiliation(s)
- Željka Knežević
- Ruđer Bošković Institute, Zagreb, Croatia
- *Correspondence: Željka Knežević,
| | - Liliana Stolarczyk
- Danish Centre for Particle Therapy, Aarhus, Denmark
- Institute of Nuclear Physics, PAN, Krakow, Poland
| | - Iva Ambrožová
- Nuclear Physics Institute of the Czech Academy of Sciences, CAS, Řež, Czechia
| | | | - Marie Davídková
- Nuclear Physics Institute of the Czech Academy of Sciences, CAS, Řež, Czechia
| | | | | | - Kinga Jeleń
- Institute of Nuclear Physics, PAN, Krakow, Poland
- Tadeusz Kosciuszko Cracow University of Technology, Cracow, Poland
| | - Renata Kopeć
- Institute of Nuclear Physics, PAN, Krakow, Poland
| | | | | | | | | | - Maite Romero-Expósito
- Universitat Autònoma de Barcelona, Bellaterra, Spain
- Skandion Clinic, Uppsala, Sweden
| | | | - Roger M. Harrison
- University of Newcastle upon Tyne, Newcastle upon Tyne, United Kingdom
| | - Paweł Olko
- Institute of Nuclear Physics, PAN, Krakow, Poland
| |
Collapse
|
10
|
Dell'Oro M, Short M, Wilson P, Peukert D, Hua CH, Merchant TE, Bezak E. Lifetime attributable risk of radiation induced second primary cancer from scattering and scanning proton therapy - A model for out-of-field organs of paediatric patients with cranial cancer. Radiother Oncol 2022; 172:65-75. [DOI: 10.1016/j.radonc.2022.04.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Revised: 03/28/2022] [Accepted: 04/25/2022] [Indexed: 10/18/2022]
|
11
|
Macaeva E, Tabury K, Michaux A, Janssen A, Averbeck N, Moreels M, De Vos WH, Baatout S, Quintens R. High-LET Carbon and Iron Ions Elicit a Prolonged and Amplified p53 Signaling and Inflammatory Response Compared to low-LET X-Rays in Human Peripheral Blood Mononuclear Cells. Front Oncol 2021; 11:768493. [PMID: 34888245 PMCID: PMC8649625 DOI: 10.3389/fonc.2021.768493] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 11/01/2021] [Indexed: 12/29/2022] Open
Abstract
Understanding the differences in biological response to photon and particle radiation is important for optimal exploitation of particle therapy for cancer patients, as well as for the adequate application of radiation protection measures for astronauts. To address this need, we compared the transcriptional profiles of isolated peripheral blood mononuclear cells 8 h after exposure to 1 Gy of X-rays, carbon ions or iron ions with those of non-irradiated cells using microarray technology. All genes that were found differentially expressed in response to either radiation type were up-regulated and predominantly controlled by p53. Quantitative PCR of selected genes revealed a significantly higher up-regulation 24 h after exposure to heavy ions as compared to X-rays, indicating their prolonged activation. This coincided with increased residual DNA damage as evidenced by quantitative γH2AX foci analysis. Furthermore, despite the converging p53 signature between radiation types, specific gene sets related to the immune response were significantly enriched in up-regulated genes following irradiation with heavy ions. In addition, irradiation, and in particular exposure to carbon ions, promoted transcript variation. Differences in basal and iron ion exposure-induced expression of DNA repair genes allowed the identification of a donor with distinct DNA repair profile. This suggests that gene signatures may serve as a sensitive indicator of individual DNA damage repair capacity. In conclusion, we have shown that photon and particle irradiation induce similar transcriptional pathways, albeit with variable amplitude and timing, but also elicit radiation type-specific responses that may have implications for cancer progression and treatment
Collapse
Affiliation(s)
- Ellina Macaeva
- Radiobiology Unit, Studiecentrum voor kernenergie - Centre d'étude de l'énergie nucléaire (SCK CEN), Mol, Belgium.,Department of Molecular Biotechnology, Ghent University, Ghent, Belgium.,Department of Oncology, KU Leuven, Leuven, Belgium
| | - Kevin Tabury
- Radiobiology Unit, Studiecentrum voor kernenergie - Centre d'étude de l'énergie nucléaire (SCK CEN), Mol, Belgium.,Department of Biomedical Engineering, University of South Carolina, Columbia, SC, United States
| | - Arlette Michaux
- Radiobiology Unit, Studiecentrum voor kernenergie - Centre d'étude de l'énergie nucléaire (SCK CEN), Mol, Belgium
| | - Ann Janssen
- Radiobiology Unit, Studiecentrum voor kernenergie - Centre d'étude de l'énergie nucléaire (SCK CEN), Mol, Belgium
| | - Nicole Averbeck
- Department of Biophysics, GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | - Marjan Moreels
- Radiobiology Unit, Studiecentrum voor kernenergie - Centre d'étude de l'énergie nucléaire (SCK CEN), Mol, Belgium
| | - Winnok H De Vos
- Department of Veterinary Sciences, University of Antwerp, Antwerp, Belgium
| | - Sarah Baatout
- Radiobiology Unit, Studiecentrum voor kernenergie - Centre d'étude de l'énergie nucléaire (SCK CEN), Mol, Belgium.,Department of Molecular Biotechnology, Ghent University, Ghent, Belgium
| | - Roel Quintens
- Radiobiology Unit, Studiecentrum voor kernenergie - Centre d'étude de l'énergie nucléaire (SCK CEN), Mol, Belgium
| |
Collapse
|
12
|
Rodrigues AJ, Jin MC, Wu A, Bhambhvani HP, Li G, Grant GA. Risk of secondary neoplasms after external-beam radiation therapy treatment of pediatric low-grade gliomas: a SEER analysis, 1973-2015. J Neurosurg Pediatr 2021; 28:306-314. [PMID: 34144522 DOI: 10.3171/2021.1.peds20859] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Accepted: 01/22/2021] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Although past studies have associated external-beam radiation therapy (EBRT) with higher incidences of secondary neoplasms (SNs), its effect on SN development from pediatric low-grade gliomas (LGGs), defined as WHO grade I and II gliomas of astrocytic or oligodendrocytic origin, is not well understood. Utilizing a national cancer registry, the authors sought to characterize the risk of SN development after EBRT treatment of pediatric LGG. METHODS A total of 1245 pediatric patient (aged 0-17 years) records from 1973 to 2015 were assembled from the Surveillance, Epidemiology, and End Results (SEER) database. Univariable and multivariable subdistribution hazard regression models were used to evaluate the prognostic impact of demographic, tumor, and treatment-related covariates. Propensity score matching was used to balance baseline characteristics. Cumulative incidence analyses measured the time to, and rate of, SN development, stratified by receipt of EBRT and controlled for competing mortality risk. The Fine and Gray semiparametric model was used to estimate future SN risk in EBRT- and non-EBRT-treated pediatric patients. RESULTS In this study, 366 patients received EBRT and 879 did not. Forty-six patients developed SNs after an LGG diagnosis, and 27 of these patients received EBRT (OR 3.61, 95% CI 1.90-6.95; p < 0.001). For patients alive 30 years from the initial LGG diagnosis, the absolute risk of SN development in the EBRT-treated cohort was 12.61% (95% CI 8.31-13.00) compared with 4.99% (95% CI 4.38-12.23) in the non-EBRT-treated cohort (p = 0.013). Cumulative incidence curves that were adjusted for competing events still demonstrated higher rates of SN development in the EBRT-treated patients with LGGs. After matching across available covariates and again adjusting for the competing risk of mortality, a clear association between EBRT and SN development remained (subhazard ratio 2.26, 95% CI 1.21-4.20; p = 0.010). CONCLUSIONS Radiation therapy was associated with an increased risk of future SNs for pediatric patients surviving LGGs. These data suggest that the long-term implications of EBRT should be considered when making treatment decisions for this patient population.
Collapse
|
13
|
Sitathanee C, Tangboonduangjit P, Dhanachai M, Suntiwong S, Yongvithisatid P, Rutchantuk S, Changkaew P, Watjiranon R, Khachonkham S, Boonkitticharoen V. Secondary cancer risk from modern external-beam radiotherapy of prostate cancer patients: Impact of fractionation and dose distribution. JOURNAL OF RADIATION RESEARCH 2021; 62:707-717. [PMID: 33993271 PMCID: PMC8273793 DOI: 10.1093/jrr/rrab038] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 03/10/2021] [Indexed: 06/12/2023]
Abstract
Modern radiotherapy (RT) uses altered fractionation, long beam-on time and image-guided procedure. This study aimed to compare secondary cancer risk (SCR) associated with primary field, scatter/leakage radiations and image-guided procedure in prostate treatment using intensity-modulated RT (IMRT), CyberKnife stereotactic body RT (CK-SBRT) in relative to 3-dimensional conformal RT (3D-CRT). Prostate plans were generated for 3D-CRT, IMRT (39 fractions of 2 Gy), and CK-SBRT (five fractions of 7.25 Gy). Excess absolute risk (EAR) was calculated for organs in the primary field using Schneider's mechanistic model and concept of organ equivalent dose (OED) to account for dose inhomogeneity. Doses from image-guided procedure and scatter/leakage radiations were determined by phantom measurements. The results showed that hypofractionation relative to conventional fractionation yielded lower SCR for organs in primary field (p ≤ 0.0001). SCR was further modulated by dose-volume distribution. For organs near the field edge, like the rectum and pelvic bone, CK-SBRT plan rendered better risk profiles than IMRT and 3D-CRT because of the absence of volume peak in high dose region (relative risk [RR]: 0.65, 0.22, respectively, p ≤ 0.0004). CK-SBRT and IMRT generated more scatter/leakage and imaging doses than 3D-CRT (p ≤ 0.0002). But primary field was the major contributor to SCR. EAR estimates (risk contributions, primary field: scatter/leakage radiations: imaging procedure) were 7.1 excess cases per 104 person-year (PY; 3.64:2.25:1) for CK-SBRT, 9.93 (7.32:2.33:1) for IMRT and 8.24 (15.99:2.35:1) for 3D-CRT (p ≤ 0.0002). We conclude that modern RT added more but small SCR from scatter/leakage and imaging doses. The primary field is a major contributor of risk which can be mitigated by the use of hypofractionation.
Collapse
Affiliation(s)
- Chomporn Sitathanee
- Corresponding author. Department of Diagnostic and Therapeutic Radiology, Ramathibodi Hospital, Mahidol University, Bangkok 10400, Thailand, E-mail:
| | - Puangpen Tangboonduangjit
- Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok 10400, Thailand
| | - Mantana Dhanachai
- Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok 10400, Thailand
| | - Sawanee Suntiwong
- Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok 10400, Thailand
| | - Pornpan Yongvithisatid
- Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok 10400, Thailand
| | - Sukanya Rutchantuk
- Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok 10400, Thailand
| | - Pimolpun Changkaew
- Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok 10400, Thailand
| | - Rattana Watjiranon
- Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok 10400, Thailand
| | - Suphalak Khachonkham
- Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok 10400, Thailand
| | - Vipa Boonkitticharoen
- Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok 10400, Thailand
| |
Collapse
|
14
|
Taylor S, Lim P, Ahmad R, Alhadi A, Harris W, Rompokos V, D'Souza D, Gaze M, Gains J, Veiga C. Risk of radiation-induced second malignant neoplasms from photon and proton radiotherapy in paediatric abdominal neuroblastoma. Phys Imaging Radiat Oncol 2021; 19:45-52. [PMID: 34307918 PMCID: PMC8295851 DOI: 10.1016/j.phro.2021.06.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Revised: 05/28/2021] [Accepted: 06/18/2021] [Indexed: 12/02/2022] Open
Abstract
BACKGROUND AND PURPOSE State-of-the-art radiotherapy modalities have the potential of reducing late effects of treatment in childhood cancer survivors. Our aim was to investigate the carcinogenic risk associated with 3D conformal (photon) radiation (3D-CRT), intensity modulated arc therapy (IMAT) and pencil beam scanning proton therapy (PBS-PT) in the treatment of paediatric abdominal neuroblastoma. MATERIALS AND METHODS The risk of radiation-induced second malignant neoplasm (SMN) was estimated using the concept of organ equivalent dose (OED) for eleven organs (lungs, rectum, colon, stomach, small intestine, liver, bladder, skin, central nervous system (CNS), bone, and soft tissues). The risk ratio (RR) between radiotherapy modalities and lifetime absolute risks (LAR) were reported for twenty abdominal neuroblastoma patients (median, 4y; range, 1-9y) historically treated with 3D-CRT that were also retrospectively replanned for IMAT and PBS-PT. RESULTS The risk of SMN due to primary radiation was reduced in PBS-PT against 3D-CRT and IMAT for most patients and organs. The RR across all organs ranged from 0.38 ± 0.22 (bladder) to 0.98 ± 0.04 (CNS) between PBS-PT and IMAT, and 0.12 ± 0.06 (rectum and bladder) to 1.06 ± 0.43 (bone) between PBS-PT and 3D-CRT. The LAR for most organs was within 0.01-1% (except the colon) with a cumulative risk of 21 ± 13%, 35 ± 14% and 35 ± 16% for PBS-PT, IMAT and 3D-CRT, respectively. CONCLUSIONS PBS-PT was associated with the lowest risk of radiation-induced SMN compared to IMAT and 3D-CRT in abdominal neuroblastoma treatment. Other clinical endpoints and plan robustness should also be considered for optimal plan selection.
Collapse
Affiliation(s)
- Sophie Taylor
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | - Pei Lim
- Department of Oncology, University College London Hospitals NHS Foundation Trust, London, UK
| | - Reem Ahmad
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | - Ammar Alhadi
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | - William Harris
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | - Vasilis Rompokos
- Radiotherapy Physics Services, University College London Hospitals NHS Foundation Trust, London, UK
| | - Derek D'Souza
- Radiotherapy Physics Services, University College London Hospitals NHS Foundation Trust, London, UK
| | - Mark Gaze
- Department of Oncology, University College London Hospitals NHS Foundation Trust, London, UK
| | - Jennifer Gains
- Department of Oncology, University College London Hospitals NHS Foundation Trust, London, UK
| | - Catarina Veiga
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| |
Collapse
|
15
|
Spiotto MT, McGovern SL, Gunn GB, Grosshans D, McAleer MF, Frank SJ, Paulino AC. Proton Radiotherapy to Reduce Late Complications in Childhood Head and Neck Cancers. Int J Part Ther 2021; 8:155-167. [PMID: 34285943 PMCID: PMC8270100 DOI: 10.14338/ijpt-20-00069.1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2020] [Accepted: 12/07/2020] [Indexed: 11/21/2022] Open
Abstract
In most childhood head and neck cancers, radiotherapy is an essential component of treatment; however, it can be associated with problematic long-term complications. Proton beam therapy is accepted as a preferred radiation modality in pediatric cancers to minimize the late radiation side effects. Given that childhood cancers are a rare and heterogeneous disease, the support for proton therapy comes from risk modeling and a limited number of cohort series. Here, we discuss the role of proton radiotherapy in pediatric head and neck cancers with a focus on reducing radiation toxicities. First, we compare the efficacy and expected toxicities in proton and photon radiotherapy for childhood cancers. Second, we review the benefit of proton radiotherapy in reducing acute and late radiation toxicities, including risks for secondary cancers, craniofacial development, vision, and cognition. Finally, we review the cost effectiveness for proton radiotherapy in pediatric head and neck cancers. This review highlights the benefits of particle radiotherapy for pediatric head and neck cancers to improve the quality of life in cancer survivors, to reduce radiation morbidities, and to maximize efficient health care use.
Collapse
Affiliation(s)
- Michael T Spiotto
- Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Susan L McGovern
- Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - G Brandon Gunn
- Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - David Grosshans
- Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Mary Frances McAleer
- Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Steven J Frank
- Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Arnold C Paulino
- Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, USA
| |
Collapse
|
16
|
Lifetime radiation-induced sarcoma risk in patients subjected to IMRT or VMAT for uterine cervix carcinoma. Phys Eng Sci Med 2021; 44:573-579. [PMID: 33909230 DOI: 10.1007/s13246-021-01002-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Accepted: 04/14/2021] [Indexed: 01/08/2023]
Abstract
This study was conducted to estimate the lifetime radiation-induced bone and soft tissue sarcoma risks from intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) for uterine cervix carcinoma. 13 cervical cancer patients were included. The bone and soft tissue structures were defined on patients' treatment planning computed tomography (CT) scans. Both CT-based IMRT and VMAT plans with 6 MV photons delivering 45 Gy to the target site were designed for each patient. The organ equivalent dose (OED) and the lifetime attributable risk (LAR) for developing bone or soft tissue sarcoma were estimated using treatment planning data and a non-linear mechanistic model. The estimation method did not consider the survival rates following radiotherapy and the use of brachytherapy treatments. The patient-specific OEDs of the bone structure from IMRT and VMAT were 2.33-2.83 and 2.34-2.82 Gy, respectively. The corresponding values for the soft tissue structure were 1.27-1.70 and 1.32-1.73 Gy. An insignificant difference was found between the patient-specific OEDs and the directly proportional sarcoma risks (bone: P = 0.07; soft tissue: P = 0.38). The LAR for the development of a bone sarcoma varied from 0.05 to 0.16% by the patient's age during irradiation and the applied treatment delivery technique. The corresponding LAR range for radiation-induced soft-tissue sarcoma was 0.08-0.27%. The above LARs resulted in a relative risk of more than 1.20 indicating that IMRT or VMAT may lead to a considerable risk increase of developing bone or soft tissue sarcoma exceeding 20% in respect to the current incidence of these malignancies in unexposed population.
Collapse
|
17
|
Gallagher KJ, Youssef B, Georges R, Mahajan A, Feghali JA, Nabha R, Ayoub Z, Jalbout W, Taddei PJ. Proton Radiotherapy Could Reduce the Risk of Fatal Second Cancers for Children with Intracranial Tumors in Low- and Middle-Income Countries. Int J Part Ther 2021; 7:1-10. [PMID: 33829068 PMCID: PMC8019578 DOI: 10.14338/ijpt-20-00041.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Accepted: 12/08/2020] [Indexed: 11/21/2022] Open
Abstract
PURPOSE To test our hypothesis that, for young children with intracranial tumors, proton radiotherapy in a high-income country does not reduce the risk of a fatal subsequent malignant neoplasm (SMN) compared with photon radiotherapy in low- and middle-income countries. MATERIALS AND METHODS We retrospectively selected 9 pediatric patients with low-grade brain tumors who were treated with 3-dimensional conformal radiation therapy in low- and middle-income countries. Images and contours were deidentified and transferred to a high-income country proton therapy center. Clinically commissioned treatment planning systems of each academic hospital were used to calculate absorbed dose from the therapeutic fields. After fusing supplemental computational phantoms to the patients' anatomies, models from the literature were applied to calculate stray radiation doses. Equivalent doses were determined in organs and tissues at risk of SMNs, and the lifetime attributable risk of SMN mortality (LAR) was predicted using a dose-effect model. Our hypothesis test was based on the average of the ratios of LARs from proton therapy to that of photon therapy ()(H0: = 1; H A : < 1). RESULTS Proton therapy reduced the equivalent dose in organs at risk for SMNs and LARs compared with photon therapy for which the for the cohort was 0.69 ± 0.10, resulting in the rejection of H0 (P < .001, α = 0.05). We observed that the younger children in the cohort (2-4 years old) were at a factor of approximately 2.5 higher LAR compared with the older children (8-12 years old). CONCLUSION Our findings suggest that proton radiotherapy has the strong potential of reducing the risk of fatal SMNs in pediatric patients with intracranial tumors if it were made available globally.
Collapse
Affiliation(s)
- Kyle J. Gallagher
- Oregon Health and Science University, Portland, OR, USA
- Oregon State University, Corvallis, OR, USA
| | - Bassem Youssef
- American University of Beirut Medical Center, Beirut, Lebanon
| | - Rola Georges
- University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Anita Mahajan
- Radiation Oncology Department, Mayo Clinic, Rochester, MN, USA
| | | | - Racile Nabha
- American University of Beirut Medical Center, Beirut, Lebanon
| | - Zeina Ayoub
- American University of Beirut Medical Center, Beirut, Lebanon
| | - Wassim Jalbout
- American University of Beirut Medical Center, Beirut, Lebanon
| | - Phillip J. Taddei
- American University of Beirut Medical Center, Beirut, Lebanon
- Radiation Oncology Department, Mayo Clinic, Rochester, MN, USA
- University of Washington School of Medicine, Seattle, WA, USA
| |
Collapse
|
18
|
Chao PJ, Tsai IH, Huang CC, Lin CH, Shieh CS, Hsieh YW, Yang PY, Lee HF, Lee TF. Radiation-Induced Secondary Cancer Risk Assessment in Patients With Lung Cancer After Stereotactic Body Radiotherapy Using the CyberKnife M6 System With Lung-Optimized Treatment. Front Bioeng Biotechnol 2020; 8:306. [PMID: 32457880 PMCID: PMC7223476 DOI: 10.3389/fbioe.2020.00306] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2019] [Accepted: 03/20/2020] [Indexed: 12/21/2022] Open
Abstract
Background To evaluate the lifetime secondary cancer risk (SCR) of stereotactic body radiotherapy (SBRT) using the CyberKnife (CK) M6 system with a lung-optimized treatment (LOT) module for lung cancer patients. Methods We retrospectively enrolled 11 lung cancer patients curatively treated with SBRT using the CK M6 robotic radiosurgery system. The planning treatment volume (PTV) and common organs at risk (OARs) for SCR analysis included the spinal cord, total lung, and healthy normal lung tissue (total lung volume - PTV). Schneider’s full model was used to calculate SCR according to the concept of organ equivalent dose (OED). Results CK-LOT-SBRT delivers precisely targeted radiation doses to lung cancers and achieves good PTV coverage and conformal dose distribution, thus posing limited SCR to surrounding tissues. The three OARs had similar risk equivalent dose (RED) values among four different models. However, for the PTV, differences in RED values were observed among the models. The cumulative excess absolute risk (EAR) value for the normal lung, spinal cord, and PTV was 70.47 (per 10,000 person-years). Schneider’s Lnt model seemed to overestimate the EAR/lifetime attributable risk (LAR). Conclusion For lung cancer patients treated with CK-LOT optimized with the Monte Carlo algorithm, the SCR might be lower. Younger patients had a greater SCR, although the dose–response relationship seemed be non-linear for the investigated organs, especially with respect to the PTV. Despite the etiological association, the SCR after CK-LOT-SBRT for carcinoma and sarcoma, is low, but not equal to zero. Further research is required to understand and to show the lung SBRT SCR comparisons and differences across different modalities with motion management strategies.
Collapse
Affiliation(s)
- Pei-Ju Chao
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - I-Hsing Tsai
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan
| | - Chun-Chieh Huang
- Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Chih-Hsueh Lin
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan
| | - Chin-Shiuh Shieh
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan
| | - Yang-Wei Hsieh
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Pei-Ying Yang
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Hsiao-Fei Lee
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Tsair-Fwu Lee
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan.,Biomedical Engineering, Kaohsiung Medical University, Kaohsiung, Taiwan
| |
Collapse
|
19
|
Chen M, Yepes P, Hojo Y, Poenisch F, Li Y, Chen J, Xu C, He X, Gunn GB, Frank SJ, Sahoo N, Li H, Zhu XR, Zhang X. Transitioning from measurement-based to combined patient-specific quality assurance for intensity-modulated proton therapy. Br J Radiol 2019; 93:20190669. [PMID: 31799859 DOI: 10.1259/bjr.20190669] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE This study is part of ongoing efforts aiming to transit from measurement-based to combined patient-specific quality assurance (PSQA) in intensity-modulated proton therapy (IMPT). A Monte Carlo (MC) dose-calculation algorithm is used to improve the independent dose calculation and to reveal the beam modeling deficiency of the analytical pencil beam (PB) algorithm. METHODS A set of representative clinical IMPT plans with suboptimal PSQA results were reviewed. Verification plans were recalculated using an MC algorithm developed in-house. Agreements of PB and MC calculations with measurements that quantified by the γ passing rate were compared. RESULTS The percentage of dose planes that met the clinical criteria for PSQA (>90% γ passing rate using 3%/3 mm criteria) increased from 71.40% in the original PB calculation to 95.14% in the MC recalculation. For fields without beam modifiers, nearly 100% of the dose planes exceeded the 95% γ passing rate threshold using the MC algorithm. The model deficiencies of the PB algorithm were found in the proximal and distal regions of the SOBP, where MC recalculation improved the γ passing rate by 11.27% (p < 0.001) and 16.80% (p < 0.001), respectively. CONCLUSIONS The MC algorithm substantially improved the γ passing rate for IMPT PSQA. Improved modeling of beam modifiers would enable the use of the MC algorithm for independent dose calculation, completely replacing additional depth measurements in IMPT PSQA program. For current users of the PB algorithm, further improving the long-tail modeling or using MC simulation to generate the dose correction factor is necessary. ADVANCES IN KNOWLEDGE We justified a change in clinical practice to achieve efficient combined PSQA in IMPT by using the MC algorithm that was experimentally validated in almost all the clinical scenarios in our center. Deficiencies in beam modeling of the current PB algorithm were identified and solutions to improve its dose-calculation accuracy were provided.
Collapse
Affiliation(s)
- Mei Chen
- Department of Radiation Oncology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.,Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Pablo Yepes
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.,Physics and Astronomy Department, Rice University, Houston, Texas, USA
| | - Yoshifumi Hojo
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Falk Poenisch
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Yupeng Li
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Jiayi Chen
- Department of Radiation Oncology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Cheng Xu
- Department of Radiation Oncology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Xiaodong He
- Department of Radiation Oncology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - G Brandon Gunn
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Steven J Frank
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Narayan Sahoo
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Heng Li
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Xiaorong Ronald Zhu
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Xiaodong Zhang
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| |
Collapse
|
20
|
Stock M, Gora J, Perpar A, Georg P, Lehde A, Kragl G, Hug E, Vondracek V, Kubes J, Poulova Z, Algranati C, Cianchetti M, Schwarz M, Amichetti M, Kajdrowicz T, Kopeć R, Mierzwińska G, Olko P, Skowrońska K, Sowa U, Góra E, Kisielewicz K, Sas-Korczyńska B, Skóra T, Bäck A, Gustafsson M, Sooaru M, Witt Nyström P, Nyman J, Björk Eriksson T. Harmonization of proton treatment planning for head and neck cancer using pencil beam scanning: first report of the IPACS collaboration group. Acta Oncol 2019; 58:1720-1730. [PMID: 31393203 DOI: 10.1080/0284186x.2019.1648858] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Background and purpose: A collaborative network between proton therapy (PT) centres in Trento in Italy, Poland, Austria, Czech Republic and Sweden (IPACS) was founded to implement trials and harmonize PT. This is the first report of IPACS with the aim to show the level of harmonization that can be achieved for proton therapy planning of head and neck (sino-nasal) cancer.Methods: CT-data sets of five patients were included. During several face-to-face and online meetings, a common treatment planning protocol was developed. Each centre used its own treatment planning system (TPS) and planning approach with some restrictions specified in the treatment planning protocol. In addition, volumetric modulated arc therapy (VMAT) photon plans were created.Results: For CTV1, the average Dmedian was 59.3 ± 2.4 Gy(RBE) for protons and 58.8 ± 2.0 Gy(RBE) for VMAT (aim was 56 Gy(RBE)). For CTV2, the average Dmedian was 71.2 ± 1.0 Gy(RBE) for protons and 70.6 ± 0.4 Gy(RBE) for VMAT (aim was 70 Gy(RBE)). The average D2% for the spinal cord was 25.1 ± 8.5 Gy(RBE) for protons and 47.6 ± 1.4 Gy(RBE) for VMAT. The average D2% for chiasm was 46.5 ± 4.4 Gy(RBE) for protons and 50.8 ± 1.4 Gy(RBE) for VMAT, respectively. Robust evaluation was performed and showed the least robust plans for plans with a low number of beams.Discussion: In conclusion, several influences on harmonization were identified: adherence/interpretation to/of the protocol, available technology, experience in treatment planning and use of different beam arrangements. In future, all OARs that should be included in the optimization need to be specified in order to further harmonize treatment planning.
Collapse
Affiliation(s)
- Markus Stock
- MedAustron Ion Therapy Centre, Wiener Neustadt, Austria
| | - Joanna Gora
- MedAustron Ion Therapy Centre, Wiener Neustadt, Austria
| | - Ana Perpar
- MedAustron Ion Therapy Centre, Wiener Neustadt, Austria
| | - Petra Georg
- MedAustron Ion Therapy Centre, Wiener Neustadt, Austria
| | | | | | - Eugen Hug
- MedAustron Ion Therapy Centre, Wiener Neustadt, Austria
| | | | - Jiri Kubes
- Proton Therapy Centre Czech, Radiation Oncology, Prague, Czechia
| | - Zuzana Poulova
- Proton Therapy Centre Czech, Medical Physics, Prague, Czechia
| | - Carlo Algranati
- U.O. di Protonterapia- Azienda Provinciale per I Servizi Sanitari Trento, Trento, Italy
| | - Marco Cianchetti
- U.O. di Protonterapia- Azienda Provinciale per I Servizi Sanitari Trento, Trento, Italy
| | - Marco Schwarz
- U.O. di Protonterapia- Azienda Provinciale per I Servizi Sanitari Trento, Trento, Italy
| | - Maurizio Amichetti
- U.O. di Protonterapia- Azienda Provinciale per I Servizi Sanitari Trento, Trento, Italy
| | - Tomasz Kajdrowicz
- Institute of Nuclear Physics Polish Academy of Sciences, Cyclotron Centre Bronowice, Kraków, Poland
| | - Renata Kopeć
- Institute of Nuclear Physics Polish Academy of Sciences, Cyclotron Centre Bronowice, Kraków, Poland
| | - Gabriela Mierzwińska
- Institute of Nuclear Physics Polish Academy of Sciences, Cyclotron Centre Bronowice, Kraków, Poland
| | - Paweł Olko
- Institute of Nuclear Physics Polish Academy of Sciences, Cyclotron Centre Bronowice, Kraków, Poland
| | - Katarzyna Skowrońska
- Institute of Nuclear Physics Polish Academy of Sciences, Cyclotron Centre Bronowice, Kraków, Poland
| | - Urszula Sowa
- Institute of Nuclear Physics Polish Academy of Sciences, Cyclotron Centre Bronowice, Kraków, Poland
| | - Eleonora Góra
- Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Radiation Oncology, Kraków, Poland
| | - Kamil Kisielewicz
- Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Radiation Oncology, Kraków, Poland
| | - Beata Sas-Korczyńska
- Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Radiation Oncology, Kraków, Poland
| | - Tomasz Skóra
- Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Radiation Oncology, Kraków, Poland
| | - Anna Bäck
- The Skandion Clinic, Uppsala, Sweden
- Department of Therapeutic Radiation Physics, Sahlgrenska University Hospital, Göteborg, Sweden
- Department of Radiation Physics, University of Gothenburg, Göteborg, Sweden
| | - Magnus Gustafsson
- The Skandion Clinic, Uppsala, Sweden
- Department of Therapeutic Radiation Physics, Sahlgrenska University Hospital, Göteborg, Sweden
| | - Maret Sooaru
- The Skandion Clinic, Uppsala, Sweden
- Department of Therapeutic Radiation Physics, Sahlgrenska University Hospital, Göteborg, Sweden
| | - Petra Witt Nyström
- The Skandion Clinic, Uppsala, Sweden
- Danish Centre for Particle Therapy, Aarhus, Denmark
| | - Jan Nyman
- Department of Oncology, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Thomas Björk Eriksson
- The Skandion Clinic, Uppsala, Sweden
- Department of Oncology, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Sahlgrenska University Hospital, Gothenburg, Sweden
- Regional Cancer Center West, Göteborg, Sweden
| |
Collapse
|
21
|
Shafai-Erfani G, Lei Y, Liu Y, Wang Y, Wang T, Zhong J, Liu T, McDonald M, Curran WJ, Zhou J, Shu HK, Yang X. MRI-Based Proton Treatment Planning for Base of Skull Tumors. Int J Part Ther 2019; 6:12-25. [PMID: 31998817 DOI: 10.14338/ijpt-19-00062.1] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2019] [Accepted: 08/15/2019] [Indexed: 01/22/2023] Open
Abstract
Purpose To introduce a novel, deep-learning method to generate synthetic computed tomography (SCT) scans for proton treatment planning and evaluate its efficacy. Materials and Methods 50 Patients with base of skull tumors were divided into 2 nonoverlapping training and study cohorts. Computed tomography and magnetic resonance imaging pairs for patients in the training cohort were used for training our novel 3-dimensional generative adversarial network (cycleGAN) algorithm. Upon completion of the training phase, SCT scans for patients in the study cohort were predicted based on their magnetic resonance images only. The SCT scans obtained were compared against the corresponding original planning computed tomography scans as the ground truth, and mean absolute errors (in Hounsfield units [HU]) and normalized cross-correlations were calculated. Proton plans of 45 Gy in 25 fractions with 2 beams per plan were generated for the patients based on their planning computed tomographies and recalculated on SCT scans. Dose-volume histogram endpoints were compared. A γ-index analysis along 3 cardinal planes intercepting at the isocenter was performed. Proton distal range along each beam was calculated. Results Image quality metrics show agreement between the generated SCT scans and the ground truth with mean absolute error values ranging from 38.65 to 65.12 HU and an average of 54.55 ± 6.81 HU and a normalized cross-correlation average of 0.96 ± 0.01. The dosimetric evaluation showed no statistically significant differences (p > 0.05) within planning target volumes for dose-volume histogram endpoints and other metrics studied, with the exception of the dose covering 95% of the target volume, with a relative difference of 0.47%. The γ-index analysis showed an average passing rate of 98% with a 10% threshold and 2% and 2-mm criteria. Proton ranges of 48 of 50 beams (96%) in this study were within clinical tolerance adopted by 4 institutions. Conclusions This study shows our method is capable of generating SCT scans with acceptable image quality, dose distribution agreement, and proton distal range compared with the ground truth. Our results set a promising approach for magnetic resonance imaging-based proton treatment planning.
Collapse
Affiliation(s)
- Ghazal Shafai-Erfani
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Yang Lei
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Yingzi Liu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Yinan Wang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Tonghe Wang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Jim Zhong
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Tian Liu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Mark McDonald
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Walter J Curran
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Jun Zhou
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Hui-Kuo Shu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| |
Collapse
|
22
|
Plan Quality and Secondary Cancer Risk Assessment in Patients with Benign Intracranial Lesions after Radiosurgery using the CyberKnife M6 Robotic Radiosurgery System. Sci Rep 2019; 9:9953. [PMID: 31289294 PMCID: PMC6616465 DOI: 10.1038/s41598-019-46133-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Accepted: 06/17/2019] [Indexed: 12/31/2022] Open
Abstract
This study was performed to examine the quality of planning and treatment modality using a CyberKnife (CK) robotic radiosurgery system with multileaf collimator (MLC)-based plans and IRIS (variable aperture collimator system)-based plans in relation to the dose–response of secondary cancer risk (SCR) in patients with benign intracranial tumors. The study population consisted of 15 patients with benign intracranial lesions after curative treatment using a CyberKnife M6 robotic radiosurgery system. Each patient had a single tumor with a median volume of 6.43 cm3 (range, 0.33–29.72 cm3). The IRIS-based plan quality and MLC-based plan quality were evaluated by comparing the dosimetric indices, taking into account the planning target volume (PTV) coverage, the conformity index (CI), and the dose gradient (R10% and R50%). The dose–response SCR with sarcoma/carcinoma induction was calculated using the concept of the organ equivalent dose (OED). Analyses of sarcoma/carcinoma induction were performed using excess absolute risk (EAR) and various OED models of dose–response type/lifetime attributable risk (LAR). Moreover, analyses were performed using the BEIR VII model. PTV coverage using both IRIS-based plans and MLC-based plans was identical, although the CI values obtained using the MLC-based plans showed greater statistical significance. In comparison with the IRIS-based plans, the MLC-based plans showed better dose falloff for R10% and R50% evaluation. The estimated difference between Schneider’s model and BEIR VII in linear-no-threshold (Lnt) cumulative EAR was about twofold. The average values of LAR/EAR for carcinoma, for the IRIS-based plans, were 25% higher than those for the MLC-based plans using four SCR models; for sarcoma, they were 15% better in Schneider’s SCR models. MLC-based plans showed slightly better conformity, dose gradients, and SCR reduction. There was a slight increase in SCR with IRIS-based plans in comparison with MLC-based plans. EAR analyses did not show any significant difference between PTV and brainstem analyses, regardless of the tumor volume. Nevertheless, an increase in target volume led to an increase in the probability of SCR. EAR showed statistically significant differences in the soft tissue according to tumor volume (1–10 cc and ≥10 cc).
Collapse
|
23
|
Are further studies needed to justify the use of proton therapy for paediatric cancers of the central nervous system? A review of current evidence. Radiother Oncol 2019; 133:140-148. [DOI: 10.1016/j.radonc.2019.01.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2018] [Revised: 12/31/2018] [Accepted: 01/09/2019] [Indexed: 11/21/2022]
|
24
|
Second malignant neoplasm risk after craniospinal irradiation in X-ray-based techniques compared to proton therapy. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2019; 42:201-209. [DOI: 10.1007/s13246-019-00731-y] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2018] [Accepted: 01/24/2019] [Indexed: 12/11/2022]
|
25
|
Mazonakis M, Kachris S, Damilakis J. SECOND CANCER RISK FROM RADIATION THERAPY FOR COMMON SOLID TUMORS DIAGNOSED IN REPRODUCTIVE-AGED FEMALES. RADIATION PROTECTION DOSIMETRY 2018; 182:208-214. [PMID: 29608744 DOI: 10.1093/rpd/ncy050] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2017] [Accepted: 03/07/2018] [Indexed: 06/08/2023]
Abstract
This study provided second cancer risk estimates from radiation therapy for common solid tumors presented in reproductive-aged females. Three-dimensional treatment plans were generated for 10 patients with cervical, uterine, rectal, lung or breast carcinomas. The organ equivalent dose (OED) and the lifetime attributable risk (LAR) for carcinogenesis to organs receiving high doses were estimated for all study participants with a mechanistic model. This model accounts for cell-killing, tissue repair and dose fractionation effects. The patient- and organ-specific relative risk was assessed by using the LARs and the respective lifetime intrinsic cancer risks for unexposed population. The OED of the organs-at-risk varied from 17.3 to 1423.1 rad. The LAR range for bladder, colon, lung and breast cancer induction was 0.12-0.14%, 10.88-12.71%, 1.66-8.62% and 0.71-3.75%, respectively. The relative risk for the appearance of bladder, colon, lung and breast malignancies following radiotherapy was up to 1.12, 4.05, 2.42 and 1.31, respectively.
Collapse
Affiliation(s)
- Michalis Mazonakis
- Department of Medical Physics, Faculty of Medicine, University of Crete, Iraklion, Crete, Greece
| | - Stefanos Kachris
- Department of Radiotherapy and Oncolgy, University Hospital of Iraklion, Iraklion, Crete, Greece
| | - John Damilakis
- Department of Medical Physics, Faculty of Medicine, University of Crete, Iraklion, Crete, Greece
| |
Collapse
|
26
|
Radiotherapy Advances in Pediatric Neuro-Oncology. Bioengineering (Basel) 2018; 5:bioengineering5040097. [PMID: 30400370 PMCID: PMC6315761 DOI: 10.3390/bioengineering5040097] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2018] [Revised: 10/26/2018] [Accepted: 11/01/2018] [Indexed: 12/31/2022] Open
Abstract
Radiation therapy (RT) represents an integral component in the treatment of many pediatric brain tumors. Multiple advances have emerged within pediatric radiation oncology that aim to optimize the therapeutic ratio—improving disease control while limiting RT-related toxicity. These include innovations in treatment planning with magnetic resonance imaging (MRI) simulation, as well as increasingly sophisticated radiation delivery techniques. Advanced RT techniques, including photon-based RT such as intensity-modulated RT (IMRT) and volumetric-modulated arc therapy (VMAT), as well as particle beam therapy and stereotactic RT, have afforded an array of options to dramatically reduce radiation exposure of uninvolved normal tissues while treating target volumes. Along with advances in image guidance of radiation treatments, novel RT approaches are being implemented in ongoing and future prospective clinical trials. As the era of molecular risk stratification unfolds, personalization of radiation dose, target, and technique holds the promise to meaningfully improve outcomes for pediatric neuro-oncology patients.
Collapse
|
27
|
Boros A, Ribrag V, Deutsch É, Chargari C, Izar F. [Radiation therapy planning for Hodgkin lymphoma: Focus on intensity-modulated radiotherapy, gating, protons. Which techniques to best deliver radiation?]. Cancer Radiother 2018; 22:404-410. [PMID: 30076071 DOI: 10.1016/j.canrad.2018.07.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2018] [Accepted: 06/21/2018] [Indexed: 11/28/2022]
Abstract
The optimization of radiotherapy in these young and long-lived survivors raises the question about the interest of using modern techniques to allow a better distribution of the dose. The choice of the irradiation technique must take into account the incidence of side effects related to radiation. In this context, the definition of the target volumes as well as the verification and monitoring of the delivered processing are essential. International recommendations for treatment fields are based on the "involved node radiotherapy" concept. The best irradiation technique to use remains to be defined. The use of intensity-modulated radiotherapy improves the coverage and reduces the dose to the organs at risk with a variable gain depending on the topography of the lymph nodes: upper or lower mediastinum, right or left lateralization, the techniques used. The deep inspiration breath-hold technique allows an increase of the pulmonary volume, extension of the mediastinum with an up down of the heart which make possible to move the planning target volume away from the cardiac structures. The volumetric-modulated arctherapy technique with several arches can be particularly interesting to reduce the dose to the breasts, as well as tomotherapy when bulky disease. Proton therapy with the Bragg peak specificity can play a key role in limiting doses to organs at risk, when robust planning that will take into account geometric and physical uncertainties is available. The heterogeneity of Hodgkin lymphomas in terms of volume, shape and initial location are the key elements to take into account when choosing the preferred radiotherapy technique.
Collapse
Affiliation(s)
- A Boros
- Département de radiothérapie, Cancer campus Grand-Paris, Gustave-Roussy, 114, rue Édouard-Vaillant, 94800 Villejuif, France; Université Paris Sud, université Paris Saclay, 94270 Le Kremlin-Bicêtre, France.
| | - V Ribrag
- Département d'hématologie, Cancer campus Grand-Paris, Gustave-Roussy, 114, rue Édouard-Vaillant, 94800 Villejuif, France; Département des innovations thérapeutiques et essais précoces, Cancer campus Grand-Paris, Gustave-Roussy, 114, rue Édouard-Vaillant, 94800 Villejuif, France
| | - É Deutsch
- Département de radiothérapie, Cancer campus Grand-Paris, Gustave-Roussy, 114, rue Édouard-Vaillant, 94800 Villejuif, France; Université Paris Sud, université Paris Saclay, 94270 Le Kremlin-Bicêtre, France; U1030, Inserm, molecular radiotherapy, 114, rue Édouard-Vaillant, 94800 Villejuif, France
| | - C Chargari
- Département de radiothérapie, Cancer campus Grand-Paris, Gustave-Roussy, 114, rue Édouard-Vaillant, 94800 Villejuif, France; Université Paris Sud, université Paris Saclay, 94270 Le Kremlin-Bicêtre, France; D19, institut de recherche biomédicale des armées, 91220 Brétigny-sur-Orge, France; Service de santé des armées, école du Val-de-Grâce, 74, boulevard de Port-Royal, 75005 Paris, France
| | - F Izar
- Département de radiothérapie, Institut universitaire du cancer de Toulouse, 1, avenue Irène-Joliot-Curie, 31059 Toulouse cedex 9, France
| |
Collapse
|
28
|
Bavle A, Tewari S, Sisson A, Chintagumpala M, Anderson M, Paulino AC. Meta-analysis of the incidence and patterns of second neoplasms after photon craniospinal irradiation in children with medulloblastoma. Pediatr Blood Cancer 2018; 65:e27095. [PMID: 29693784 DOI: 10.1002/pbc.27095] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2018] [Revised: 03/08/2018] [Accepted: 03/19/2018] [Indexed: 11/10/2022]
Abstract
BACKGROUND Second neoplasms (SNs) are a well-established long-term adverse effect of radiation therapy (RT), but there are limited data regarding their incidence and location relative to the radiation field, specific to medulloblastoma (MB) survivors after craniospinal irradiation (CSI). METHODS A systematic literature review, per Preferred Reporting Items for Systematic Reviews and Meta-Analyses, identified six studies reporting the incidence and locations of SNs for 1,114 patients with MB, after CSI, with a median follow-up of ∼9 years (7.6-15.4 years). The study-specific cumulative incidence (CI) of SNs, second benign neoplasms (SBNs), and second malignant neoplasms (SMNs) were standardized to a 10-year time frame. Meta-analysis was performed using random effects models, with pooled data from selected studies and an institutional cohort of 55 patients. RESULTS The 10-year CI was 6.1% for all SNs (excluding skin cancer and leukemia), 3.1% for SBNs, and 3.7% for SMNs. Fifty-eight percent of SNs were malignant; high-grade glioma was the most common SMN (15/33; 45%) and meningioma, the most common SBN (16/24; 67%). Forty percent of SNs occurred outside the target central nervous system (CNS) field, with a majority in areas of exit RT dose. Seventy-four percent of extra-CNS tumors (17/23) were malignant, most commonly thyroid carcinoma (7/17; 41%) and bone and soft-tissue tumors (6/17, 35%). CONCLUSIONS Survivors of MB are at risk of SNs both within and outside the CNS. A significant proportion of SNs occur in areas of exit RT dose. Studies are needed to determine whether the use of proton therapy, which has no exit RT dose, is associated with a lower incidence of SNs.
Collapse
Affiliation(s)
- Abhishek Bavle
- Jimmy Everest Center for Cancer and Blood Disorders, Oklahoma City, Oklahoma.,University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma
| | - Sayani Tewari
- Jimmy Everest Center for Cancer and Blood Disorders, Oklahoma City, Oklahoma.,University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma
| | - Amy Sisson
- The Texas Medical Center Library, Houston, Texas
| | - Murali Chintagumpala
- Section of Pediatric Hematology/Oncology, Baylor College of Medicine, Houston, Texas.,Texas Children's Hospital, Houston, Texas
| | - Michael Anderson
- University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma.,Department of Biostatistics and Epidemiology, Oklahoma City, Oklahoma
| | - Arnold C Paulino
- The University of Texas MD Anderson Cancer Center, Houston, Texas
| |
Collapse
|
29
|
Radiation-induced second cancer risk from stereotactic ablative radiotherapy (SABR) for lung cancer: a review of planning studies. JOURNAL OF RADIOTHERAPY IN PRACTICE 2018. [DOI: 10.1017/s1460396917000528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractPurposeThe aim of the current study was to (i) to calculate organ equivalent dose (OED) and (ii) to estimate excess absolute risks (EARs), lifetime attributable risks (LARs) and relative risks (RRs) from stereotactic ablative radiotherapy (SABR) for lung cancer to in-field, close to field, and out of field structures.MethodsA total of five patients with T1, T2 (≤4 cm), N0, M0 medically inoperable non-small cell lung cancer were selected for treatment planning. Patient selection criteria were based on RTOG 0236. Five treatment deliveries were investigated: (i) three-dimensional conformal radiotherapy (3DCRT), (ii) intensity-modulated radiotherapy (IMRT), (iii) intensity-modulated radiotherapy with flattening filter free beam (IMRTF), (iv) volumetric modulated arc therapy (VMAT) and (v) volumetric modulated arc therapy with flattening filter free arcs (VMATF). Delineated normal structures included chest wall, left and right lung, trachea, small and large airways, spinal cord, oesophagus and involved ribs. All plans were prescribed to 60 Gy in five fractions to primary planning target volume (PTV) volume so that ≥98% of the PTV received ≥98% of the prescription dose and internal tumour volume received 100% of the prescription dose. The OED for all delineated normal structures was calculated using differential dose volume histograms. Using risk models, the age-dependent LAR’s and RR were calculated. Additionally, the secondary cancer risk for organs inside primary radiation was analysed using sarcoma and carcinoma risk models.ResultsFor all patients, the mean V20 volumes from the SABR plans were 4·1% (3DRT), 11·8% (IMRT), and 12·7% (VMAT), respectively. The EAR (combining all organs EAR) for all the organs studied, ranged from 8·5 to 10·6/10,000 persons/year for VMATF and 3DCRT, respectively. The EAR (combining all organs EAR) for all the organs studied, ranged from 8·5 to 10·6/10,000 persons/year for VMATF and 3DCRT, respectively. The absolute EAR difference between IMRT and IMRTF was low ranging from 0·2 to 0·4/10,000 persons-year, whereas delivery difference (IMRT and VMAT) had a significant impact on EAR with absolute difference ranging from 0·5 to 1·0/10,000 persons-year for IMRT and VMAT and 1·1–1·5/10,000 persons-year for IMRTF, VMATF, respectively. The LAR data showed a strong dependence on age at exposure and the LAR decreased as a function of age at exposure. The absolute attributable risk of bone sarcoma was lower with the VMAT plan and was significantly higher with the 3DCRT plan.ConclusionFrom a clinical perspective, it should be concluded that all five solutions investigated in the study can offer high quality of patient treatments and only estimates of radiation-induced malignancies can truly differentiate among them. The results suggested it would be reasonable to use the cumulative LAR difference when needed to select between treatment techniques. In conclusion, the LAR of radiation-induced secondary cancer was significantly lower when using VMATF than when using IMRT for SABR lung patients. VMATF would be the right choice for the treatment of SABR lung patients in terms of LAR. However, more work is required for the specific estimation and long-term validation and updating of the models behind LAR estimation.
Collapse
|
30
|
Affiliation(s)
- Thomas R Bortfeld
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA
| | | |
Collapse
|
31
|
Tang HM, Fung MC, Tang HL. Detecting Anastasis In Vivo by CaspaseTracker Biosensor. J Vis Exp 2018. [PMID: 29443051 DOI: 10.3791/54107] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
Abstract
Anastasis (Greek for "rising to life") is a recently discovered cell recovery phenomenon whereby dying cells can reverse late-stage cell death processes that are generally assumed to be intrinsically irreversible. Promoting anastasis could in principle rescue or preserve injured cells that are difficult to replace such as cardiomyocytes or neurons, thereby facilitating tissue recovery. Conversely, suppressing anastasis in cancer cells, undergoing apoptosis after anti-cancer therapies, may ensure cancer cell death and reduce the chances of recurrence. However, these studies have been hampered by the lack of tools for tracking the fate of cells that undergo anastasis in live animals. The challenge is to identify the cells that have reversed the cell death process despite their morphologically normal appearance after recovery. To overcome this difficulty, we have developed Drosophila and mammalian CaspaseTracker biosensor systems that can identify and permanently track the anastatic cells in vitro or in vivo. Here, we present in vivo protocols for the generation and use of the CaspaseTracker dual biosensor system to detect and track anastasis in Drosophila melanogaster after transient exposure to cell death stimuli. While conventional biosensors and protocols can label cells actively undergoing apoptotic cell death, the CaspaseTracker biosensor can permanently label cells that have recovered after caspase activation - a hallmark of late-stage apoptosis, and simultaneously identify active apoptotic processes. This biosensor can also track the recovery of the cells that attempted other forms of cell death that directly or indirectly involved caspase activity. Therefore, this protocol enables us to continuously track the fate of these cells and their progeny, facilitating future studies of the biological functions, molecular mechanisms, physiological and pathological consequences, and therapeutic implications of anastasis. We also discuss the appropriate controls to distinguish cells that undergo anastasis from those that display non-apoptotic caspase activity in vivo.
Collapse
Affiliation(s)
- Ho Man Tang
- Institute for Basic Biomedical Sciences, Johns Hopkins University School of Medicine; School of Life Sciences, Chinese University of Hong Kong;
| | - Ming Chiu Fung
- School of Life Sciences, Chinese University of Hong Kong;
| | - Ho Lam Tang
- Department of Neurosurgery, Johns Hopkins University School of Medicine;
| |
Collapse
|
32
|
Lee HF, Lan JH, Chao PJ, Ting HM, Chen HC, Hsu HC, Lee TF. Radiation-induced secondary malignancies for nasopharyngeal carcinoma: a pilot study of patients treated via IMRT or VMAT. Cancer Manag Res 2018; 10:131-141. [PMID: 29403311 PMCID: PMC5783017 DOI: 10.2147/cmar.s145713] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Background Patients treated with radiotherapy are at risk of developing a second cancer during their lifetime, which can directly impact treatment decision-making and patient management. The aim of this study was to qualify and compare the secondary cancer risk (SCR) after intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in nasopharyngeal carcinoma (NPC) patients. Patients and methods We analyzed the treatment plans of a cohort of 10 NPC patients originally treated with IMRT or VMAT. Dose distributions in these plans were used to calculate the organ equivalent dose (OED) with Schneider’s full model. Analyses were applied to the brain stem, spinal cord, oral cavity, pharynx, parotid glands, lung, mandible, healthy tissue, and planning target volume. Results We observed that the OED-based risks of SCR were slightly higher for the oral cavity and mandible when VMAT was used. No significant difference was found in terms of the doses to other organs, including the brain stem, parotids, pharynx, submandibular gland, lung, spinal cord, and healthy tissue. In the NPC cohort, the lungs were the organs that were most sensitive to radiation-induced cancer. Conclusion VMAT afforded superior results in terms of organ-at-risk-sparing compared with IMRT. Most OED-based second cancer risks for various organs were similar when VMAT and IMRT were employed, but the risks for the oral cavity and mandible were slightly higher when VMAT was used.
Collapse
Affiliation(s)
- Hsiao-Fei Lee
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung, Taiwan, Republic of China.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, Republic of China
| | - Jen-Hong Lan
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung, Taiwan, Republic of China.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, Republic of China
| | - Pei-Ju Chao
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung, Taiwan, Republic of China.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, Republic of China
| | - Hui-Min Ting
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung, Taiwan, Republic of China.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, Republic of China
| | - Hui-Chun Chen
- Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, Republic of China
| | - Hsuan-Chih Hsu
- Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, Republic of China
| | - Tsair-Fwu Lee
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung, Taiwan, Republic of China.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, Republic of China.,Graduate Institute of Clinical Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan, Republic of China.,Department of Radiation Oncology, Kaohsiung Yuan's General Hospital, Kaohsiung, Taiwan, Republic of China
| |
Collapse
|
33
|
Chao PJ, Lee HF, Lan JH, Guo SS, Ting HM, Huang YJ, Chen HC, Lee TF. Propensity-score-matched evaluation of the incidence of radiation pneumonitis and secondary cancer risk for breast cancer patients treated with IMRT/VMAT. Sci Rep 2017; 7:13771. [PMID: 29062118 PMCID: PMC5653804 DOI: 10.1038/s41598-017-14145-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2017] [Accepted: 10/05/2017] [Indexed: 11/09/2022] Open
Abstract
Propensity score matching evaluates the treatment incidence of radiation-induced pneumonitis (RP) and secondary cancer risk (SCR) after intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for breast cancer patients. Of 32 patients treated with IMRT and 58 who received VMAT were propensity matched in a 1:1 ratio. RP and SCR were evaluated as the endpoints of acute and chronic toxicity, respectively. Self-fitted normal tissue complication probability (NTCP) parameter values were used to analyze the risk of RP. SCRs were evaluated using the preferred Schneider's parameterization risk models. The dosimetric parameter of the ipsilateral lung volume receiving 40 Gy (IV40) was selected as the dominant risk factor for the RP NTCP model. The results showed that the risks of RP and NTCP, as well as that of SCR of the ipsilateral lung, were slightly lower than the values in patients treated with VMAT versus IMRT (p ≤ 0.01). However, the organ equivalent dose and excess absolute risk values in the contralateral lung and breast were slightly higher with VMAT than with IMRT (p ≤ 0.05). When compared to IMRT, VMAT is a rational radiotherapy option for breast cancer patients, based on its reduced potential for inducing secondary malignancies and RP complications.
Collapse
Affiliation(s)
- Pei-Ju Chao
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung, 80778, Taiwan, ROC.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, 83342, Taiwan, ROC
| | - Hsiao-Fei Lee
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung, 80778, Taiwan, ROC.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, 83342, Taiwan, ROC
| | - Jen-Hong Lan
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung, 80778, Taiwan, ROC.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, 83342, Taiwan, ROC
| | - Shih-Sian Guo
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung, 80778, Taiwan, ROC.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, 83342, Taiwan, ROC
| | - Hui-Min Ting
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung, 80778, Taiwan, ROC.,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, 83342, Taiwan, ROC
| | - Yu-Jie Huang
- Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, 83342, Taiwan, ROC
| | - Hui-Chun Chen
- Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, 83342, Taiwan, ROC.
| | - Tsair-Fwu Lee
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung, 80778, Taiwan, ROC. .,Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, 83342, Taiwan, ROC. .,Graduate Institute of Clinical Medicine, Kaohsiung Medical University, Kaohsiung 807, Taiwan, ROC. .,Department of Radiation Oncology, Kaohsiung Yuan's General Hospital, Kaohsiung, 80249, Taiwan, ROC.
| |
Collapse
|
34
|
Mohan R, Das IJ, Ling CC. Empowering Intensity Modulated Proton Therapy Through Physics and Technology: An Overview. Int J Radiat Oncol Biol Phys 2017; 99:304-316. [PMID: 28871980 PMCID: PMC5651132 DOI: 10.1016/j.ijrobp.2017.05.005] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2017] [Revised: 04/11/2017] [Accepted: 05/02/2017] [Indexed: 01/15/2023]
Abstract
Considering the clinical potential of protons attributable to their physical characteristics, interest in proton therapy has increased greatly in this century, as has the number of proton therapy installations. Until recently, passively scattered proton therapy was used almost entirely. Notably, the overall clinical results to date have not shown a convincing benefit of protons over photons. A rapid transition is now occurring with the implementation of the most advanced form of proton therapy, intensity modulated proton therapy (IMPT). IMPT is superior to passively scattered proton therapy and intensity modulated radiation therapy (IMRT) dosimetrically. However, numerous limitations exist in the present IMPT methods. In particular, compared with IMRT, IMPT is highly vulnerable to various uncertainties. In this overview we identify three major areas of current limitations of IMPT: treatment planning, treatment delivery, and motion management, and discuss current and future efforts for improvement. For treatment planning, we need to reduce uncertainties in proton range and in computed dose distributions, improve robust planning and optimization, enhance adaptive treatment planning and delivery, and consider how to exploit the variability in the relative biological effectiveness of protons for clinical benefit. The quality of proton therapy also depends on the characteristics of the IMPT delivery systems and image guidance. Efforts are needed to optimize the beamlet spot size for both improved dose conformality and faster delivery. For the latter, faster energy switching time and increased dose rate are also needed. Real-time in-room volumetric imaging for guiding IMPT is in its early stages with cone beam computed tomography (CT) and CT-on-rails, and continued improvements are anticipated. In addition, imaging of the proton beams themselves, using, for instance, prompt γ emissions, is being developed to determine the proton range and to reduce range uncertainty. With the realization of the advances described above, we posit that IMPT, thus empowered, will lead to substantially improved clinical results.
Collapse
Affiliation(s)
- Radhe Mohan
- Department of Radiation Physics, MD Anderson Cancer Center, Houston, Texas.
| | - Indra J Das
- Department of Radiation Oncology, New York University Langone Medical Center, New York, New York
| | - Clifton C Ling
- Varian Medical Systems and Department of Radiation Oncology, Stanford University, Stanford, California
| |
Collapse
|
35
|
Predicting Organ-Specific Risk Interactions between Radiation and Chemotherapy in Secondary Cancer Survivors. Cancers (Basel) 2017; 9:cancers9090119. [PMID: 28878202 PMCID: PMC5615334 DOI: 10.3390/cancers9090119] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2017] [Revised: 08/29/2017] [Accepted: 09/04/2017] [Indexed: 01/09/2023] Open
Abstract
Several studies have shown that pediatric patients have an increased risk of developing a secondary malignancy several decades after treatment with radiotherapy and chemotherapy. In this work, we use a biologically motivated mathematical formalism to estimate the relative risks of breast, lung and thyroid cancers in childhood cancer survivors due to concurrent therapy regimen. This model specifically includes possible organ-specific interaction between radiotherapy and chemotherapy. The model predicts relative risks for developing secondary cancers after chemotherapy in breast, lung and thyroid tissues, and compared with the epidemiological data. For a concurrent therapy protocol, our model predicted relative risks of 3.2, 9.3, 4.5 as compared to the clinical data, i.e., 1.4, 8.0, 2.3 for secondary breast, lung and thyroid cancer risks, respectively. The extracted chemotherapy mutation induction rates for breast, lung and thyroid are 10−9, 0.5 × 10−6, 0.9 × 10−7 respectively. We found that there exists no synergistic interaction between radiation and chemotherapy for neither mutation induction nor cell kill in lung tissue, but there is an interaction in cell kill for the breast and thyroid organs. These findings help understand the risks of current clinical protocols and might provide rational guidance to develop future multi-modality treatment protocols to minimize secondary cancer risks.
Collapse
|
36
|
Masood U, Cowan TE, Enghardt W, Hofmann KM, Karsch L, Kroll F, Schramm U, Wilkens JJ, Pawelke J. A light-weight compact proton gantry design with a novel dose delivery system for broad-energetic laser-accelerated beams. Phys Med Biol 2017; 62:5531-5555. [DOI: 10.1088/1361-6560/aa7124] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
37
|
Second cancer risk assessments after involved-site radiotherapy for mediastinal Hodgkin lymphoma. Med Phys 2017; 44:3866-3874. [DOI: 10.1002/mp.12327] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2017] [Revised: 04/11/2017] [Accepted: 05/01/2017] [Indexed: 12/19/2022] Open
|
38
|
Tamura M, Sakurai H, Mizumoto M, Kamizawa S, Murayama S, Yamashita H, Takao S, Suzuki R, Shirato H, Ito YM. Lifetime attributable risk of radiation-induced secondary cancer from proton beam therapy compared with that of intensity-modulated X-ray therapy in randomly sampled pediatric cancer patients. JOURNAL OF RADIATION RESEARCH 2017; 58:363-371. [PMID: 27789564 PMCID: PMC5440886 DOI: 10.1093/jrr/rrw088] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2016] [Revised: 08/01/2016] [Accepted: 08/05/2016] [Indexed: 05/20/2023]
Abstract
To investigate the amount that radiation-induced secondary cancer would be reduced by using proton beam therapy (PBT) in place of intensity-modulated X-ray therapy (IMXT) in pediatric patients, we analyzed lifetime attributable risk (LAR) as an in silico surrogate marker of the secondary cancer after these treatments. From 242 pediatric patients with cancers who were treated with PBT, 26 patients were selected by random sampling after stratification into four categories: (i) brain, head and neck, (ii) thoracic, (iii) abdominal, and (iv) whole craniospinal (WCNS) irradiation. IMXT was replanned using the same computed tomography and region of interest. Using the dose-volume histograms (DVHs) of PBT and IMXT, the LARs of Schneider et al. were calculated for the same patient. All the published dose-response models were tested for the organs at risk. Calculation of the LARs of PBT and IMXT based on the DVHs was feasible for all patients. The means ± standard deviations of the cumulative LAR difference between PBT and IMXT for the four categories were (i) 1.02 ± 0.52% (n = 7, P = 0.0021), (ii) 23.3 ± 17.2% (n = 8, P = 0.0065), (iii) 16.6 ± 19.9% (n = 8, P = 0.0497) and (iv) 50.0 ± 21.1% (n = 3, P = 0.0274), respectively (one tailed t-test). The numbers needed to treat (NNT) were (i) 98.0, (ii) 4.3, (iii) 6.0 and (iv) 2.0 for WCNS, respectively. In pediatric patients who had undergone PBT, the LAR of PBT was significantly lower than the LAR of IMXT estimated by in silico modeling. Although a validation study is required, it is suggested that the LAR would be useful as an in silico surrogate marker of secondary cancer induced by different radiotherapy techniques.
Collapse
Affiliation(s)
- Masaya Tamura
- Department of Radiation Medicine, Hokkaido University Graduate School of Medicine, Kita 15, Nishi 7, Kita-ku, Sapporo, 060-8638, Japan
| | - Hideyuki Sakurai
- Proton Medical Research Center, University of Tsukuba, Amakubo 2-1-1, Tsukuba, 305-8576, Japan
| | - Masashi Mizumoto
- Proton Medical Research Center, University of Tsukuba, Amakubo 2-1-1, Tsukuba, 305-8576, Japan
| | - Satoshi Kamizawa
- Proton Medical Research Center, University of Tsukuba, Amakubo 2-1-1, Tsukuba, 305-8576, Japan
| | - Shigeyuki Murayama
- Proton Therapy Division, Shizuoka Cancer Center Hospital, 1007 Shimonagakubo, Nagaizumi, Shizuoka, 411-8777, Japan
| | - Haruo Yamashita
- Proton Therapy Division, Shizuoka Cancer Center Hospital, 1007 Shimonagakubo, Nagaizumi, Shizuoka, 411-8777, Japan
| | - Seishin Takao
- Department of Medical Physics, Hokkaido University Hospital, Kita 14, Nishi 5, Kita-ku, Sapporo, 060-8648, Japan
| | - Ryusuke Suzuki
- Department of Medical Physics, Hokkaido University Hospital, Kita 14, Nishi 5, Kita-ku, Sapporo, 060-8648, Japan
| | - Hiroki Shirato
- Department of Radiation Medicine, Hokkaido University Graduate School of Medicine, Kita 15, Nishi 7, Kita-ku, Sapporo, 060-8638, Japan
- Quantum Medical Science and Engineering, Hokkaido University Graduate School of Medicine, Kita 15, Nishi 7, Kita-ku, Sapporo, 060-8638, Japan
| | - Yoichi M. Ito
- Department of Biostatistics, Hokkaido University Graduate School of Medicine, Kita 15, Nishi 7, Kita-ku, Sapporo, 060-8638, Japan
- Corresponding author. Department of Biostatistics, Hokkaido University Graduate School of Medicine, Kita 15, Nishi 7, Kita-ku, Sapporo, 060-8638, Japan. Tel: +81-11-706-5896; Fax: +81-11-706-6050;
| |
Collapse
|
39
|
Chargari C, Goodman KA, Diallo I, Guy JB, Rancoule C, Cosset JM, Deutsch E, Magne N. Risk of second cancers in the era of modern radiation therapy: does the risk/benefit analysis overcome theoretical models? Cancer Metastasis Rev 2017; 35:277-88. [PMID: 26970966 DOI: 10.1007/s10555-016-9616-2] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
In the era of modern radiation therapy, the compromise between the reductions in deterministic radiation-induced toxicities through highly conformal devices may be impacting the stochastic risk of second malignancies. We reviewed the clinical literature and evolving theoretical models evaluating the impact of intensity-modulated radiation therapy (IMRT) on the risk of second cancers, as a consequence of the increase in volumes of normal tissues receiving low doses. The risk increase (if any) is not as high as theoretical models have predicted in adults. Moreover, the increase in out-of-field radiation doses with IMRT could be counterbalanced by the decrease in volumes receiving high doses. Clinical studies with short follow-up have not corroborated the hypothesis that IMRT would drastically increase the incidence of second cancers. In children, the risk of radiation-induced carcinogenesis increases from low doses and consequently the relative risk of second cancers after IMRT could be higher than in adults, justifying current developments of proton therapy with priority given to this population. Although only longer follow-up will allow a true assessment of the real impact of these modern techniques on radiation-induced carcinogenesis, a comprehensive risk-adapted strategy will help minimize the probability of second cancers.
Collapse
Affiliation(s)
- Cyrus Chargari
- Radiotherapy Department, Hôpital d'Instruction des Armées du Val-de-Grâce, Paris, France.,INSERM 1030, Molecular Radiotherapy, Gustave Roussy campus Cancer, Grand Paris, France
| | - Karyn A Goodman
- Department of Radiation Oncology, University of Colorado School of Medicine, Aurora, CO, USA
| | - Ibrahima Diallo
- U1018 Institut National de la Santé et de la Recherche Médicale, Villejuif, France
| | - Jean-Baptiste Guy
- Cellular and Molecular Radiotherapy Laboratory, EMR3738, 69921, Oullins, France.,Department of Radiotherapy, Lucien Neuwirth Cancer Institute, Saint Priest en Jarez, France
| | - Chloe Rancoule
- Department of Radiotherapy, Lucien Neuwirth Cancer Institute, Saint Priest en Jarez, France
| | - Jean-Marc Cosset
- Oncology/Radiotherapy Department, Institut Curie, 75005, Paris, France.,Charlebourg-La Défense Radiotherapy Center, Amethyst Group, La Garenne-Colombes, 92250, Paris, France
| | - Eric Deutsch
- INSERM 1030, Molecular Radiotherapy, Gustave Roussy campus Cancer, Grand Paris, France
| | - Nicolas Magne
- Cellular and Molecular Radiotherapy Laboratory, EMR3738, 69921, Oullins, France. .,Department of Radiotherapy, Lucien Neuwirth Cancer Institute, Saint Priest en Jarez, France. .,Chef du Département de Radiothérapie, Directeur de la Recherche et de l'Innovation, Institut de Cancérologie Lucien Neuwirth, 108 bis, avenue Albert Raimond, BP 60008, 42270, Saint-Priest en Jarez cedex, France.
| |
Collapse
|
40
|
Tran A, Zhang J, Woods K, Yu V, Nguyen D, Gustafson G, Rosen L, Sheng K. Treatment planning comparison of IMPT, VMAT and 4π radiotherapy for prostate cases. Radiat Oncol 2017; 12:10. [PMID: 28077128 PMCID: PMC5225526 DOI: 10.1186/s13014-016-0761-0] [Citation(s) in RCA: 57] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2016] [Accepted: 12/29/2016] [Indexed: 11/10/2022] Open
Abstract
Background Intensity-modulated proton therapy (IMPT), non-coplanar 4π intensity-modulated radiation therapy (IMRT), and volumetric-modulated arc therapy (VMAT) represent the most advanced treatment methods based on heavy ion and X-rays, respectively. Here we compare their performance for prostate cancer treatment. Methods Ten prostate patients were planned using IMPT with robustness optimization, VMAT, and 4π to an initial dose of 54 Gy to a clinical target volume (CTV) that encompassed the prostate and seminal vesicles, then a boost prescription dose of 25.2 Gy to the prostate for a total dose of 79.2 Gy. The IMPT plans utilized two coplanar, oblique scanning beams 10° posterior of the lateral beam positions. Range uncertainties were taken into consideration in the IMPT plans. VMAT plans used two full, coplanar arcs to ensure sufficient PTV coverage. 4π plans were created by inversely selecting and optimizing 30 beams from 1162 candidate non-coplanar beams using a greedy column generation algorithm. CTV doses, bladder and rectum dose volumes (V40, V45, V60, V65, V70, V75, and V80), R100, R50, R10, and CTV homogeneity index (D95/D5) were evaluated. Results Compared to IMPT, 4π resulted in lower anterior rectal wall mean dose as well as lower rectum V40, V45, V60, V65, V70, and V75. Due to the opposing beam arrangement, IMPT resulted in significantly (p < 0.05) greater femoral head doses. However, IMPT plans had significantly lower bladder, rectum, and anterior rectal wall max dose. IMPT doses were also significantly more homogeneous than 4π and VMAT doses. Conclusion Compared to the VMAT and 4π plans, IMPT treatment plans are superior in CTV homogeneity and maximum point organ-at-risk (OAR) doses with the exception of femur heads. IMPT is inferior in rectum and bladder volumes receiving intermediate to high doses, particularly to the 4π plans, but significantly reduced low dose spillage and integral dose, which are correlated to secondary cancer for patients with expected long survival. The dosimetric benefits of 4π plans over VMAT are consistent with the previous publication.
Collapse
Affiliation(s)
- Angelia Tran
- Department of Radiation Oncology, University of California, Los Angeles, 200 Medical Plaza Way, Suite B265, Los Angeles, CA, 90095, USA
| | - Jingjing Zhang
- Department of Radiation Oncology, Beaumont Health System, Royal Oak, USA
| | - Kaley Woods
- Department of Radiation Oncology, University of California, Los Angeles, 200 Medical Plaza Way, Suite B265, Los Angeles, CA, 90095, USA
| | - Victoria Yu
- Department of Radiation Oncology, University of California, Los Angeles, 200 Medical Plaza Way, Suite B265, Los Angeles, CA, 90095, USA
| | - Dan Nguyen
- Department of Radiation Oncology, University of California, Los Angeles, 200 Medical Plaza Way, Suite B265, Los Angeles, CA, 90095, USA
| | - Gary Gustafson
- Department of Radiation Oncology, Beaumont Health System, Royal Oak, USA
| | - Lane Rosen
- Department of Radiation Oncology, Willis-Knighton Cancer Center, Shreveport, USA
| | - Ke Sheng
- Department of Radiation Oncology, University of California, Los Angeles, 200 Medical Plaza Way, Suite B265, Los Angeles, CA, 90095, USA.
| |
Collapse
|
41
|
Strategies to Overcome Late Complications from Radiotherapy for Childhood Head and Neck Cancers. Oral Maxillofac Surg Clin North Am 2016; 28:115-26. [PMID: 26614704 DOI: 10.1016/j.coms.2015.07.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Most pediatric head and neck cancers are treated with radiotherapy, but the morbidity associated with radiotherapy has become a prominent issue. This article discusses the common long-term complications associated with head and neck radiotherapy for childhood cancers. It reviews approaches to minimize toxicity and details the toxicities that head and neck radiation inflicts on relevant functional measures. In addition, it discusses the risk of radiation-induced secondary cancers in childhood cancer survivors, as well as strategies to reduce them. Thus, this article addresses approaches to minimize long-term radiation toxicities in order to improve the quality of life for childhood cancer survivors.
Collapse
|
42
|
Proton therapy for paediatric CNS tumours — improving treatment-related outcomes. Nat Rev Neurol 2016; 12:334-45. [DOI: 10.1038/nrneurol.2016.70] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
43
|
Yonekura Y, Tsujii H, Hopewell JW, Ortiz López P, Cosset JM, Paganetti H, Montelius A, Schardt D, Jones B, Nakamura T. Radiological protection in ion beam radiotherapy: practical guidance for clinical use of new technology. Ann ICRP 2016; 45:138-47. [PMID: 26980799 DOI: 10.1177/0146645316630708] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Recently introduced technologies in radiotherapy have significantly improved the clinical outcome for patients. Ion beam radiotherapy, involving proton and carbon ion beams, provides excellent dose distributions in targeted tumours, with reduced doses to the surrounding normal tissues. However, careful treatment planning is required in order to maximise the treatment efficiency and minimise the dose to normal tissues. Radiation exposure from secondary neutrons and photons, particle fragments, and photons from activated materials should also be considered for radiological protection of the patient and medical staff. Appropriate maintenance is needed for the equipment and air in the treatment room, which may be activated by the particle beam and its secondary radiation. This new treatment requires complex procedures and careful adjustment of parameters for each patient. Therefore, education and training for the personnel involved in the procedure are essential for both effective treatment and patient protection. The International Commission on Radiological Protection (ICRP) has provided recommendations for radiological protection in ion beam radiotherapy in Publication 127 Medical staff should be aware of the possible risks resulting from inappropriate use and control of the equipment. They should also consider the necessary procedures for patient protection when new technologies are introduced into clinical practice.
Collapse
Affiliation(s)
- Y Yonekura
- National Institute of Radiological Sciences, Anagawa 4-9-1, Inage-ku, Chiba 263-8555, Japan
| | - H Tsujii
- National Institute of Radiological Sciences, Anagawa 4-9-1, Inage-ku, Chiba 263-8555, Japan
| | - J W Hopewell
- Green Templeton College, University of Oxford, UK
| | | | | | | | | | | | - B Jones
- Gray Institute for Radiation Oncology and Biology, University of Oxford, UK
| | - T Nakamura
- Professor Emeritus of Tohoku University, Japan
| |
Collapse
|
44
|
Almohiy H. Multicenter study assessing ophthalmologist's knowledge towards radiation dose when prescribing CT scans for pediatric patients: A Saudi Arabian perspective. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES 2016. [DOI: 10.1016/j.jrras.2015.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
45
|
Rana S, Zhang Y, Larson G, Vargas C, Dunn M, Zheng Y. Investigating dosimetric effect of rotational setup errors in IMPT planning of synchronous bilateral lung cancer. INTERNATIONAL JOURNAL OF CANCER THERAPY AND ONCOLOGY 2015. [DOI: 10.14319/ijcto.34.14] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
|
46
|
Geng C, Moteabbed M, Seco J, Gao Y, George Xu X, Ramos-Méndez J, Faddegon B, Paganetti H. Dose assessment for the fetus considering scattered and secondary radiation from photon and proton therapy when treating a brain tumor of the mother. Phys Med Biol 2015; 61:683-95. [DOI: 10.1088/0031-9155/61/2/683] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
47
|
Eaton BR, MacDonald SM, Yock TI, Tarbell NJ. Secondary Malignancy Risk Following Proton Radiation Therapy. Front Oncol 2015; 5:261. [PMID: 26636040 PMCID: PMC4659915 DOI: 10.3389/fonc.2015.00261] [Citation(s) in RCA: 49] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2015] [Accepted: 11/09/2015] [Indexed: 01/17/2023] Open
Abstract
Radiation-induced secondary malignancies are a significant, yet uncommon cause of morbidity and mortality among cancer survivors. Secondary malignancy risk is dependent upon multiple factors including patient age, the biological and genetic predisposition of the individual, the volume and location of tissue irradiated, and the dose of radiation received. Proton therapy (PRT) is an advanced particle therapy with unique dosimetric properties resulting in reduced entrance dose and minimal to no exit dose when compared with standard photon radiation therapy. Multiple dosimetric studies in varying cancer subtypes have demonstrated that PRT enables the delivery of adequate target volume coverage with reduced integral dose delivered to surrounding tissues, and modeling studies taking into account dosimetry and radiation cell biology have estimated a significantly reduced risk of radiation-induced secondary malignancy with PRT. Clinical data are emerging supporting the lower incidence of secondary malignancies after PRT compared with historical photon data, though longer follow-up in proton treated cohorts is awaited. This article reviews the current dosimetric and clinical literature evaluating the incidence of and risk factors associated with radiation-induced secondary malignancy following PRT.
Collapse
Affiliation(s)
- Bree R Eaton
- Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School , Boston, MA , USA
| | - Shannon M MacDonald
- Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School , Boston, MA , USA
| | - Torunn I Yock
- Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School , Boston, MA , USA
| | - Nancy J Tarbell
- Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School , Boston, MA , USA
| |
Collapse
|
48
|
Geng C, Moteabbed M, Xie Y, Schuemann J, Yock T, Paganetti H. Assessing the radiation-induced second cancer risk in proton therapy for pediatric brain tumors: the impact of employing a patient-specific aperture in pencil beam scanning. Phys Med Biol 2015; 61:12-22. [PMID: 26605679 DOI: 10.1088/0031-9155/61/1/12] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The purpose of this study was to compare the radiation-induced second cancer risks for in-field and out-of-field organs and tissues for pencil beam scanning (PBS) and passive scattering proton therapy (PPT) and assess the impact of adding patient-specific apertures to sharpen the penumbra in pencil beam scanning for pediatric brain tumor patients. Five proton therapy plans were created for each of three pediatric patients using PPT as well as PBS with two spot sizes (average sigma of ~17 mm and ~8 mm at isocenter) and choice of patient-specific apertures. The lifetime attributable second malignancy risks for both in-field and out-of-field tissues and organs were compared among five delivery techniques. The risk for in-field tissues was calculated using the organ equivalent dose, which is determined by the dose volume histogram. For out-of-field organs, the organ-specific dose equivalent from secondary neutrons was calculated using Monte Carlo and anthropomorphic pediatric phantoms. We find that either for small spot size PBS or for large spot size PBS, a patient-specific aperture reduces the in-field cancer risk to values lower than that for PPT. The reduction for large spot sizes (on average 43%) is larger than for small spot sizes (on average 21%). For out-of-field organs, the risk varies only marginally by employing a patient-specific aperture (on average from -2% to 16% with increasing distance from the tumor), but is still one to two orders of magnitude lower than that for PPT. In conclusion, when pencil beam spot sizes are large, the addition of apertures to sharpen the penumbra decreases the in-field radiation-induced secondary cancer risk. There is a slight increase in out-of-field cancer risk as a result of neutron scatter from the aperture, but this risk is by far outweighed by the in-field risk benefit from using an aperture with a large PBS spot size. In general, the risk for developing a second malignancy in out-of-field organs for PBS remains much lower compared to PPT even if apertures are being applied.
Collapse
Affiliation(s)
- Changran Geng
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA 02114, USA. Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, People's Republic of China
| | | | | | | | | | | |
Collapse
|
49
|
Cherry SR, Ruffle J. Roberts Prize for the best paper published in 2014. Phys Med Biol 2015; 60:E1-2. [DOI: 10.1088/0031-9155/60/19/e1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
50
|
Abstract
PURPOSE Intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) provide highly conformal target radiation doses, but also expose large volumes of healthy tissue to low-dose radiation. With improving survival, more children with medulloblastoma (MB) are at risk of late adverse effects of radiotherapy, including secondary cancers. We evaluated the characteristics of IMRT and VMAT craniospinal irradiation treatment plans in children with standard-risk MB to compare radiation dose delivery to target organs and organs at risk (OAR). PATIENTS AND METHODS Each of 10 children with standard-risk MB underwent both IMRT and VMAT treatment planning. Dose calculations used inverse planning optimization with a craniospinal dose of 23.4 Gy followed by a posterior fossa boost to 55.8 Gy. Clinical and planning target volumes were demarcated on axial computed tomography images. Dose distributions to target organs and OAR for each planning technique were measured and compared with published dose-volume toxicity data for pediatric patients. RESULTS All patients completed treatment planning for both techniques. Analyses and comparisons of dose distributions and dose-volume histograms for the planned target volumes, and dose delivery to the OAR for each technique demonstrated the following: (1) VMAT had a modest, but significantly better, planning target volume-dose coverage and homogeneity compared with IMRT; (2) there were different OAR dose-sparing profiles for IMRT versus VMAT; and (3) neither IMRT nor VMAT demonstrated dose reductions to the published pediatric dose limits for the eyes, the lens, the cochlea, the pituitary, and the brain. CONCLUSIONS The use of both IMRT and VMAT provides good target tissue coverage and sparing of the adjacent tissue for MB. Both techniques resulted in OAR dose delivery within published pediatric dose guidelines, except those mentioned above. Pediatric patients with standard-risk MB remain at risk for late endocrinologic, sensory (auditory and visual), and brain functional impairments.
Collapse
|