1
|
Wegierak D, Cooley MB, Perera R, Wulftange WJ, Gurkan UA, Kolios MC, Exner AA. Decorrelation Time Mapping as an Analysis Tool for Nanobubble-Based Contrast Enhanced Ultrasound Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2024; 43:2370-2380. [PMID: 38329864 PMCID: PMC11234354 DOI: 10.1109/tmi.2024.3364076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/10/2024]
Abstract
Nanobubbles (NBs; ~100-500 nm diameter) are preclinical ultrasound (US) contrast agents that expand applications of contrast enhanced US (CEUS). Due to their sub-micron size, high particle density, and deformable shell, NBs in pathological states of heightened vascular permeability (e.g. in tumors) extravasate, enabling applications not possible with microbubbles (~1000-10,000 nm diameter). A method that can separate intravascular versus extravascular NB signal is needed as an imaging biomarker for improved tumor detection. We present a demonstration of decorrelation time (DT) mapping for enhanced tumor NB-CEUS imaging. In vitro models validated the sensitivity of DT to agent motion. Prostate cancer mouse models validated in vivo imaging potential and sensitivity to cancerous tissue. Our findings show that DT is inversely related to NB motion, offering enhanced detail of NB dynamics in tumors, and highlighting the heterogeneity of the tumor environment. Average DT was high in tumor regions (~9 s) compared to surrounding normal tissue (~1 s) with higher sensitivity to tumor tissue compared to other mapping techniques. Molecular NB targeting to tumors further extended DT (11 s) over non-targeted NBs (6 s), demonstrating sensitivity to NB adherence. From DT mapping of in vivo NB dynamics we demonstrate the heterogeneity of tumor tissue while quantifying extravascular NB kinetics and delineating intra-tumoral vasculature. This new NB-CEUS-based biomarker can be powerful in molecular US imaging, with improved sensitivity and specificity to diseased tissue and potential for use as an estimator of vascular permeability and the enhanced permeability and retention (EPR) effect in tumors.
Collapse
|
2
|
Ghahramani Z E, Grimm PD, Eary KJ, Swearengen MP, Dayavansha EGSK, Mast TD. Three-dimensional echo decorrelation monitoring of radiofrequency ablation in ex vivo bovine liver. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 151:3907. [PMID: 35778168 PMCID: PMC9187351 DOI: 10.1121/10.0011641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 05/14/2022] [Accepted: 05/23/2022] [Indexed: 06/03/2023]
Abstract
Three-dimensional (3D) echo decorrelation imaging was investigated for monitoring radiofrequency ablation (RFA) in ex vivo bovine liver. RFA experiments (N = 14) were imaged by 3D ultrasound using a matrix array, with in-phase and quadrature complex echo volumes acquired about every 11 s. Tissue specimens were then frozen at -80 °C, sectioned, and semi-automatically segmented. Receiver operating characteristic (ROC) curves were constructed for assessing ablation prediction performance of 3D echo decorrelation with three potential normalization approaches, as well as 3D integrated backscatter (IBS). ROC analysis indicated that 3D echo decorrelation imaging is potentially a good predictor of local RFA, with the best prediction performance observed for globally normalized decorrelation. Tissue temperatures, recorded by four thermocouples integrated into the RFA probe, showed good correspondence with spatially averaged decorrelation and statistically significant but weak correlation with measured echo decorrelation at the same spatial locations. In tests predicting ablation zones using a weighted K-means clustering approach, echo decorrelation performed better than IBS, with smaller root mean square volume errors and higher Dice coefficients relative to measured ablation zones. These results suggest that 3D echo decorrelation and IBS imaging are capable of real-time monitoring of thermal ablation, with potential application to clinical treatment of liver tumors.
Collapse
Affiliation(s)
- E Ghahramani Z
- Department of Biomedical Engineering, University of Cincinnati, Ohio 45267-0586, USA
| | - P D Grimm
- Department of Biomedical Engineering, University of Cincinnati, Ohio 45267-0586, USA
| | - K J Eary
- Department of Biomedical Engineering, University of Cincinnati, Ohio 45267-0586, USA
| | - M P Swearengen
- Department of Biomedical Engineering, University of Cincinnati, Ohio 45267-0586, USA
| | | | - T D Mast
- Department of Biomedical Engineering, University of Cincinnati, Ohio 45267-0586, USA
| |
Collapse
|
3
|
Abbass MA, Ahmad SA, Mahalingam N, Krothapalli KS, Masterson JA, Rao MB, Barthe PG, Mast TD. In vivo ultrasound thermal ablation control using echo decorrelation imaging in rabbit liver and VX2 tumor. PLoS One 2019; 14:e0226001. [PMID: 31805129 PMCID: PMC6894854 DOI: 10.1371/journal.pone.0226001] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Accepted: 11/18/2019] [Indexed: 12/21/2022] Open
Abstract
The utility of echo decorrelation imaging feedback for real-time control of in vivo ultrasound thermal ablation was assessed in rabbit liver with VX2 tumor. High-intensity focused ultrasound (HIFU) and unfocused (bulk) ablation were performed using 5 MHz linear image-ablate arrays. Treatments comprised up to nine lower-power sonications, followed by up to nine higher-power sonications, ceasing when the average cumulative echo decorrelation within a control region of interest exceeded a predefined threshold (- 2.3, log10-scaled echo decorrelation per millisecond, corresponding to 90% specificity for tumor ablation prediction in previous in vivo experiments). This threshold was exceeded in all cases for both HIFU (N = 12) and bulk (N = 8) ablation. Controlled HIFU trials achieved a significantly higher average ablation rate compared to comparable ablation trials without image-based control, reported previously. Both controlled HIFU and bulk ablation trials required significantly less treatment time than these previous uncontrolled trials. Prediction of local liver and VX2 tumor ablation using echo decorrelation was tested using receiver operator characteristic curve analysis, showing prediction capability statistically equivalent to uncontrolled trials. Compared to uncontrolled trials, controlled trials resulted in smaller thermal ablation regions and higher contrast between echo decorrelation in treated vs. untreated regions. These results indicate that control using echo decorrelation imaging may reduce treatment duration and increase treatment reliability for in vivo thermal ablation.
Collapse
Affiliation(s)
- Mohamed A. Abbass
- Dept of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Syed A. Ahmad
- Dept of Surgery, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Neeraja Mahalingam
- Dept of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - K. Sameer Krothapalli
- Dept of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Jack A. Masterson
- Dept of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Marepalli B. Rao
- Dept of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, United States of America
- Dept of Environmental Health, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Peter G. Barthe
- Guided Therapy Systems/Ardent Sound, Mesa, Arizona, United States of America
| | - T. Douglas Mast
- Dept of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, United States of America
| |
Collapse
|
4
|
Strigari L, Minosse S, D'Alessio D, Farina L, Cavagnaro M, Cassano B, Pinto R, Vallati G, Lopresto V. Microwave thermal ablation using CT-scanner for predicting the variation of ablated region over time: advantages and limitations. Phys Med Biol 2019; 64:115021. [PMID: 30995620 DOI: 10.1088/1361-6560/ab1a67] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
This study aims at investigating in real-time the structural and dynamical changes occurring in an ex vivo tissue during a microwave thermal ablation (MTA) procedure. The experimental set-up was based on ex vivo liver tissue inserted in a dedicated box, in which 3 fibre-optic (FO) temperature probes were introduced to measure the temperature increase over time. Computed tomography (CT) imaging technique was exploited to experimentally study in real-time the Hounsfield Units (HU) modification occurring during MTA. The collected image data were processed with a dedicated MATLAB tool, developed to analyse the FO positions and HU modifications from the CT images acquired over time before and during the ablation procedures. The radial position of a FO temperature probe (rFO) and the value of HU in the region of interest (ROI) containing the probe (HUo), along with the corresponding value of HU in the contralateral ROI with respect to the MTA antenna applicator (HUc), were determined and registered over time during and after the MTA procedure. Six experiments were conducted to confirm results. The correlation between temperature and the above listed predictors was investigated using univariate and multivariate analysis. At the multivariate analysis, the time, rFO and HUc resulted significant predictive factors of the logarithm of measured temperature. The correlation between predicted and measured temperatures was 0.934 (p < 0.001). The developed tool allows identifying and registering the image-based parameters useful for predicting the temperature variation over time in each investigated voxel by taking into consideration the HU variation.
Collapse
Affiliation(s)
- L Strigari
- Laboratory of Medical Physics and Expert Systems, IRCCS Regina Elena National Cancer Institute, IFO, via Elio Chianesi, 53, 00144, Rome, Italy. Current address: Department of Medical Physics, St. Orsola-Malpighi University Hospital, via Massarenti 9 40138 Bologna, Italy
| | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Zhou Z, Wang Y, Song S, Wu W, Wu S, Tsui PH. Monitoring Microwave Ablation Using Ultrasound Echo Decorrelation Imaging: An ex vivo Study. SENSORS (BASEL, SWITZERLAND) 2019; 19:E977. [PMID: 30823609 PMCID: PMC6412341 DOI: 10.3390/s19040977] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/21/2019] [Revised: 02/17/2019] [Accepted: 02/21/2019] [Indexed: 12/19/2022]
Abstract
In this study, a microwave-induced ablation zone (thermal lesion) monitoring method based on ultrasound echo decorrelation imaging was proposed. A total of 15 cases of ex vivo porcine liver microwave ablation (MWA) experiments were carried out. Ultrasound radiofrequency (RF) signals at different times during MWA were acquired using a commercial clinical ultrasound scanner with a 7.5-MHz linear-array transducer. Instantaneous and cumulative echo decorrelation images of two adjacent frames of RF data were calculated. Polynomial approximation images were obtained on the basis of the thresholded cumulative echo decorrelation images. Experimental results showed that the instantaneous echo decorrelation images outperformed conventional B-mode images in monitoring microwave-induced thermal lesions. Using gross pathology measurements as the reference standard, the estimation of thermal lesions using the polynomial approximation images yielded an average accuracy of 88.60%. We concluded that instantaneous ultrasound echo decorrelation imaging is capable of monitoring the change of thermal lesions during MWA, and cumulative ultrasound echo decorrelation imaging and polynomial approximation imaging are feasible for quantitatively depicting thermal lesions.
Collapse
Affiliation(s)
- Zhuhuang Zhou
- College of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China.
| | - Yue Wang
- College of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China.
| | - Shuang Song
- College of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China.
| | - Weiwei Wu
- College of Biomedical Engineering, Capital Medical University, Beijing 100054, China.
| | - Shuicai Wu
- College of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China.
| | - Po-Hsiang Tsui
- Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan.
- Medical Imaging Research Center, Institute for Radiological Research, Chang Gung University and Chang Gung Memorial Hospital at Linkou, Taoyuan 33302, Taiwan.
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, Taoyuan 33302, Taiwan.
| |
Collapse
|
6
|
Abbass MA, Garbo AJ, Mahalingam N, Killin JK, Mast TD. Optimized Echo Decorrelation Imaging Feedback for Bulk Ultrasound Ablation Control. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:1743-1755. [PMID: 29994657 PMCID: PMC6294441 DOI: 10.1109/tuffc.2018.2847599] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Feasibility of controlling bulk ultrasound (US) thermal ablation using echo decorrelation imaging was investigated in ex vivo bovine liver. The first of two ablation and control procedures used a sequence of constant-intensity sonication cycles, ceased when the minimum echo decorrelation within a control region of interest (ROI) exceeded a predetermined threshold. The second procedure used a variable-intensity sonication sequence, with spatially averaged decorrelation as the stopping criterion. US exposures and echo decorrelation imaging were performed by a linear image-ablate array. Based on preliminary experiments, control ROIs and thresholds for the minimum-decorrelation and average-decorrelation criteria were specified. Controlled trials for the minimum-decorrelation and average-decorrelation criteria were compared with uncontrolled trials employing 9 or 18 cycles of matching sonication sequences. Lesion dimensions, treatment times, ablation rates, and areas under receiver operating characteristic curves were statistically compared. Successfully controlled trials using both criteria required significantly shorter treatment times than corresponding 18-cycle treatments, with better ablation prediction performance than uncontrolled 9-cycle and 18-cycle treatments. Either control approach resulted in greater ablation rate than corresponding 9-cycle or 18-cycle uncontrolled approaches. A post hoc analysis studied the effect of exchanging control criteria between the two series of controlled experiments. For either group, the average time needed to exceed the alternative decorrelation threshold approximately matched the average duration of successfully controlled experimental trials. These results indicate that either approach, using minimum-decorrelation or average-decorrelation criteria, is feasible for control of bulk US ablation. In addition, use of a variable-intensity sonication sequence for bulk US thermal ablation can result in larger ablated regions compared to constant-intensity sonication sequences.
Collapse
|
7
|
Abbass MA, Killin JK, Mahalingam N, Hooi FM, Barthe PG, Mast TD. Real-Time Spatiotemporal Control of High-Intensity Focused Ultrasound Thermal Ablation Using Echo Decorrelation Imaging in ex Vivo Bovine Liver. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:199-213. [PMID: 29074273 PMCID: PMC5712268 DOI: 10.1016/j.ultrasmedbio.2017.09.007] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2017] [Revised: 08/28/2017] [Accepted: 09/07/2017] [Indexed: 05/05/2023]
Abstract
The ability to control high-intensity focused ultrasound (HIFU) thermal ablation using echo decorrelation imaging feedback was evaluated in ex vivo bovine liver. Sonications were automatically ceased when the minimum cumulative echo decorrelation within the region of interest exceeded an ablation control threshold, determined from preliminary experiments as -2.7 (log-scaled decorrelation per millisecond), corresponding to 90% specificity for local ablation prediction. Controlled HIFU thermal ablation experiments were compared with uncontrolled experiments employing two, five or nine sonication cycles. Means and standard errors of the lesion width, area and depth, as well as receiver operating characteristic curves testing ablation prediction performance, were computed for each group. Controlled trials exhibited significantly smaller average lesion area, width and treatment time than five-cycle or nine-cycle uncontrolled trials and also had significantly greater prediction capability than two-cycle uncontrolled trials. These results suggest echo decorrelation imaging is an effective approach to real-time HIFU ablation control.
Collapse
Affiliation(s)
- Mohamed A Abbass
- Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA
| | - Jakob K Killin
- Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA
| | | | - Fong Ming Hooi
- Ultrasound Division, Siemens Healthcare, Issaquah, Washington, USA
| | | | - T Douglas Mast
- Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA.
| |
Collapse
|