1
|
Afroz S, Østerås BH, Thevathas US, Dohlen G, Stokke C, Robsahm TE, Olerud HM. Use of ionizing radiation in a Norwegian cohort of children with congenital heart disease: imaging frequency and radiation dose for the Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Pediatrics (HARMONIC) study. Pediatr Radiol 2023; 53:2502-2514. [PMID: 37773444 PMCID: PMC10635954 DOI: 10.1007/s00247-023-05774-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 09/07/2023] [Accepted: 09/08/2023] [Indexed: 10/01/2023]
Abstract
BACKGROUND The European-funded Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Pediatrics (HARMONIC) project is a multicenter cohort study assessing the long-term effects of ionizing radiation in patients with congenital heart disease. Knowledge is lacking regarding the use of ionizing radiation from sources other than cardiac catheterization in this cohort. OBJECTIVE This study aims to assess imaging frequency and radiation dose (excluding cardiac catheterization) to patients from a single center participating in the Norwegian HARMONIC project. MATERIALS AND METHODS Between 2000 and 2020, we recruited 3,609 patients treated for congenital heart disease (age < 18 years), with 33,768 examinations categorized by modality and body region. Data were retrieved from the radiology information system. Effective doses were estimated using International Commission on Radiological Protection Publication 60 conversion factors, and the analysis was stratified into six age categories: newborn; 1 year, 5 years, 10 years, 15 years, and late adolescence. RESULTS The examination distribution was as follows: 91.0% conventional radiography, 4.0% computed tomography (CT), 3.6% diagnostic fluoroscopy, 1.2% nuclear medicine, and 0.3% noncardiac intervention. In the newborn to 15 years age categories, 4-12% had ≥ ten conventional radiography studies, 1-8% underwent CT, and 0.3-2.5% received nuclear medicine examinations. The median effective dose ranged from 0.008-0.02 mSv and from 0.76-3.47 mSv for thoracic conventional radiography and thoracic CT, respectively. The total effective dose burden from thoracic conventional radiography ranged between 28-65% of the dose burden from thoracic CT in various age categories (40% for all ages combined). The median effective dose for nuclear medicine lung perfusion was 0.6-0.86 mSv and for gastrointestinal fluoroscopy 0.17-0.27 mSv. Because of their low frequency, these procedures contributed less to the total effective dose than thoracic radiography. CONCLUSION This study shows that CT made the largest contribution to the radiation dose from imaging (excluding cardiac intervention). However, although the dose per conventional radiograph was low, the large number of examinations resulted in a substantial total effective dose. Therefore, it is important to consider the frequency of conventional radiography while calculating cumulative dose for individuals. The findings of this study will help the HARMONIC project to improve risk assessment by minimizing the uncertainty associated with cumulative dose calculations.
Collapse
Affiliation(s)
- Susmita Afroz
- Department of Optometry, Radiography and Lighting Design, University of South-Eastern Norway, Grønland 58, Drammen, Norway.
- Department of Pediatric Cardiology, Oslo University Hospital, Oslo, Norway.
| | - Bjørn H Østerås
- Department of Physics and Computational Radiology, Oslo University Hospital, Oslo, Norway
| | - Utheya S Thevathas
- Department of Optometry, Radiography and Lighting Design, University of South-Eastern Norway, Grønland 58, Drammen, Norway
- Department of Pediatric Cardiology, Oslo University Hospital, Oslo, Norway
| | - Gaute Dohlen
- Department of Pediatric Cardiology, Oslo University Hospital, Oslo, Norway
| | - Caroline Stokke
- Department of Physics and Computational Radiology, Oslo University Hospital, Oslo, Norway
- Department of Physics, University of Oslo, Oslo, Norway
| | - Trude E Robsahm
- Research Department, Cancer Registry of Norway, Oslo, Norway
| | - Hilde M Olerud
- Department of Optometry, Radiography and Lighting Design, University of South-Eastern Norway, Grønland 58, Drammen, Norway
| |
Collapse
|
2
|
Miranda P, Vano E, Ubeda C, Figueroa X, Doggenweiller P, Oliveira M, Dalmazzo D. RADIATION DOSE FOR PATIENTS WITH KAWASAKI DISEASE UNDERGOING FLUOROSCOPICALLY GUIDED CARDIAC CATHETERIZATION. RADIATION PROTECTION DOSIMETRY 2021; 197:230-236. [PMID: 34979032 DOI: 10.1093/rpd/ncab182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Revised: 11/14/2021] [Accepted: 12/08/2021] [Indexed: 06/14/2023]
Abstract
The goal of the present study was to estimate the radiation dose for a group of 45 Kawasaki disease (KD) patients undergoing fluoroscopically guided cardiac catheterization. The sample of procedures corresponds to a single hospital and was collected in 10 years. Anthropometric characteristics and the quantities of air kerma-area product (PKA) among others were recorded for each procedure. Monte Carlo PCXMC 2.0 software was used to estimate organ and effective doses. The PKA value of 7.2 Gy cm2 was proposed as the local Diagnostic Reference Level for KD. For organ absorbed doses, median values for thyroid, heart, lungs, esophagus, skin, active bone and breast were 1.2; 2.2; 4.6; 2.7; 1.1; 1.2 and 2.7 mGy, respectively. For effective dose, the mean value was 2.7 ± 2.5 mSv. This paper presents the first patient dose values for the KD using catheterization techniques, in Latin America and the Caribbean Region.
Collapse
|
3
|
Nichols KJ, Gecelter R, Van Tosh A. Balancing risks and rewards in assessing pediatric heart disease. J Nucl Cardiol 2021; 28:1409-1412. [PMID: 31432466 DOI: 10.1007/s12350-019-01860-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Accepted: 07/30/2019] [Indexed: 11/27/2022]
Affiliation(s)
- Kenneth J Nichols
- Department of Radiology, Donald and Barbra Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY, USA.
- Division of Nuclear Medicine and Molecular Imaging, Northwell Health, 270-05 76th Avenue, New Hyde Park, NY, 11040, USA.
| | | | | |
Collapse
|
4
|
Han Y, Zhang X, Zhang F. Transcatheter and intraoperative device closure of atrial septal defect in infants under three years of age. J Cardiothorac Surg 2020; 15:9. [PMID: 31915066 PMCID: PMC7050609 DOI: 10.1186/s13019-020-1063-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Accepted: 01/03/2020] [Indexed: 12/21/2022] Open
Abstract
Background Transcatheter and intraoperative device closures have been widely used in the treatment of secundum atrial septal defect (ASD). However, for young infants with ASD, device closure remains controversial, and such treatment features limited data. We compared the clinical data and follow-up results of percutaneous and intraoperative device closure for ASD to evaluate the feasibility, safety, and efficacy of both treatments in infants under 3 years of age. Methods From September 2010 to September 2018, 186 children under 3 years of age with significant secundum ASD were included in this study. A total of 88 and 98 patients were divided into groups A (transcatheter device closure) and B (intraoperative device closure), respectively. The clinical data and follow-up results of the two groups were analyzed retrospectively. Result The mean age and weight of patients in group A were significantly higher than those in group B. The proportion of complex ASDs (multiples or rims deficiency) and the device/weight ratio in group B were significantly higher than those in group A. Successful closure was obtained in 86 (97.7%) and 96 (98.0%) infants in groups A and B, respectively, with two failed cases in each group (2.3% vs 2%). The rate of periprocedural complications reached 13.6 and 26.5% for groups A and B (P = 0.058), respectively. The durations of the procedure and postoperative hospital stay in group A were significantly shorter than those in group B (P < 0.05). Excellent follow-up results were observed in both groups. At present, no death nor major complications have occurred. Symptoms either resolved completely or improved significantly for all symptomatic infants. No residual shunts at the 6th month of follow-up evaluation were observed. Patients with failure to thrive gained weight appropriately for age, and the structure and hemodynamic parameters significantly improved during follow-up. Conclusion Transcatheter and intraoperative device closure are feasible, effective, and safe methods for the treatment of ASDs in infants under 3 years of age. Considering improved cosmetic effect and the short duration of the procedure and postoperative hospital stay, transcatheter is preferred for patients with appropriate conditions. Intraoperative device closure can be performed as an alternative to percutaneous closure, particularly for infants with large, complex ASDs, young age, or low-body weight.
Collapse
Affiliation(s)
- Yangyang Han
- Department of Cardiovascular Surgery, Linyi People's Hospital, Affiliated Hospital of Shandong University, Jiefang Street No. 27, Linyi, 276000, Shandong Province, China
| | - Xiquan Zhang
- Department of Cardiovascular Surgery, Qilu Hospital of Shandong University, West wenhua road No.107, Lixia district, Jinan, 250012, Shandong province, China.
| | - Fengwei Zhang
- Department of Cardiovascular Surgery, Linyi People's Hospital, Affiliated Hospital of Shandong University, Jiefang Street No. 27, Linyi, 276000, Shandong Province, China
| |
Collapse
|
5
|
Rizk C, Fares G, Vanhavere F, Saliba Z, Farah J. Diagnostic Reference Levels, Deterministic and Stochastic Risks in Pediatric Interventional Cardiology Procedures. HEALTH PHYSICS 2020; 118:85-95. [PMID: 31764423 DOI: 10.1097/hp.0000000000001114] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
To establish diagnostic reference levels (DRLs) and investigate deterministic and stochastic risks in pediatric interventional cardiology (IC) procedures. Exposure parameters were retrospectively reviewed for 373 patients treated between May 2016 and November 2018 at a single specialized hospital. Weight specific DRLs were derived for pediatric IC procedures. Additionally, peak skin dose (Dskin,max) was measured using thermoluminescent dosimeters for a sample of 7 diagnostic and 43 therapeutic procedures. Finally, using PCXMC software, organ doses were computed and the risk of exposure-induced cancer death (REID) was estimated using the risk models of the Biological Effects of Ionizing Radiation VII committee. DRLs for ventricular septal defect (VSD) occlusions, lacking in the literature, in terms of air kerma at patient entrance reference point (388 and 629 mGy) and total air kerma-area product (28 and 61 Gycm) were proposed for patients weight-groups 5 - < 15 kg and 15 - < 30 kg, respectively. The mean (range) Dskin,max was 15 (1-30) mGy and 94 (1-491) mGy for diagnostic and therapeutic procedures, respectively. Meanwhile, VSD occlusion involved the highest organ doses where the lungs, liver, stomach, and breasts mean doses were 57, 37, 6, and 10 mGy, respectively, and the associated REID were 0.5% and 0.3% in female and male patients, respectively. DRLs were proposed for pediatric IC procedures; these will help optimize patient exposure. Dskin,max values were lower than the 2 Gy threshold for skin injuries. Pediatric organ doses and the REID were the highest during VSD occlusion and may be critical for repetitive procedures.
Collapse
Affiliation(s)
| | - Georges Fares
- Faculty of Sciences, Saint Joseph University, 11-514 Beirut, Lebanon
| | - Filip Vanhavere
- Belgian Nuclear Research Centre (SCK-CEN), BE-2400 Mol, Belgium
| | - Zakhia Saliba
- Department of pediatrics, Hotel Dieu de France Hospital, Beirut, Lebanon
| | - Jad Farah
- Radiology and Nuclear Medicine Department, Paris-Sud University Hospitals, 94270 Le Kremlin-Bicêtre, France
| |
Collapse
|
6
|
Osei B, Xu L, Johnston A, Darko S, Darko J, Osei E. Retrospective study of patients radiation dose during cardiac catheterization procedures. Br J Radiol 2019; 92:20181021. [PMID: 31045448 PMCID: PMC6636266 DOI: 10.1259/bjr.20181021] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Revised: 04/19/2019] [Accepted: 04/24/2019] [Indexed: 01/19/2023] Open
Abstract
OBJECTIVE Cardiac catheterization procedures provide tremendous benefits to modern healthcare and the benefit derived by the patient should far outweigh the radiation risk associated with a properly optimized procedure. With increasing utilization of such procedures, there is growing concern regarding the magnitude and variations of dose to patients associated with procedure complexity and techniques parameters. Therefore, this study investigated radiation dose to patients from six cardiac catheterization procedures at our facility and suggest possible initial dose values for benchmark for patient radiation dose from these procedures. This initial benchmark data will be used for clinical radiation dose management which is essential for assessing the impact of any quality improvement initiatives in the cardiac catheterization laboratory. METHODS We retrospectively analyzed the dose parameters of 1000 patients who underwent various cardiac catheterization procedures: left heart catheterization (LH), percutaneous coronary intervention (PCI), complex PCI, LH with complex PCI, LH with PCI and cardiac resynchronization therapy (CRT) pacemaker in our cardiac catheterization laboratories. Patient's clinical radiation dose data [kerma-area-product (KAP) and air-kerma at the interventional reference point (Ka,r)] and technique parameters (fluoroscopy time, tube potential, current, pulse width and number of cine images) along with demographic information (age, height and weight) were collected from the hospital's RIS (Synapse), Sensis/Syngo Dynamics and Siemens Sensis Stats Manager electronic database. Statistical analysis was performed with the IBM SPSS Modeler v. 18.1 software. RESULTS The overall patient median age was 67.0 (range: 26.0-97.0) years and the median body mass index (BMI) was 28.8 (range: 15.9-61.7) kg/m2 . The median KAP for the LH, PCI, LH with complex PCI, complex PCI, LH with PCI and CRT-pacemaker procedures are 44.4 (4.1-203.2), 80.2 (18.9-208.5), 83.7 (48.0-246.1), 113.8 (60.9-284.5), 91.7 (6.0-426.0) and 51.1 (7.0-175.9) Gy-cm2 . The median Ka,r for the LH, PCI, LH with complex PCI, complex PCI, LH with PCI and CRT-pacemaker procedures are 701.0 (35.3-3794.0), 1384.7 (291.7-4021.8), 1607.0 (883.5-4448.3), 2260.2 (867.4-5311.9), 1589.3 (100.2-7237.4) and 463.8 (67.7-1695.9) mGy respectively. CONCLUSION We have analyzed patient radiation doses from six commonly used procedures in our cardiac catheterization laboratories and suggested possible initial values for benchmark from these procedures for the fluoroscopy time, KAP and air-kerma at the interventional reference point based on our current practices. Our data compare well with published values reported in the literature by investigators who have also studied patient doses and established benchmark dose levels for their facilities. Procedure-specific benchmark dose data for various groups of patients can provide the motivation for monitoring practices to promote improvements in patient radiation dose optimization in the cardiac catheterization laboratories. ADVANCES IN KNOWLEDGE We have investigated local patients' radiation doses and established benchmark radiation data which are essential for assessing the impact of any quality improvement initiatives for radiation dose optimization.
Collapse
Affiliation(s)
| | | | | | - Sara Darko
- Department of Clinical Trials, Grand River Regional Cancer Centre, Kitchener, ON, Canada
| | | | | |
Collapse
|
7
|
Elmarsafawy H, Matter M, Abo-Haded HM, Rakha S, Hafez MM, Alsawah GA, Abuelkheir MM. Transcatheter closure of patent ductus arteriosus, evaluating the outcome: Single center experience in Mansoura, Egypt. PROGRESS IN PEDIATRIC CARDIOLOGY 2019. [DOI: 10.1016/j.ppedcard.2018.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
8
|
Sung KH, Jung YJ, Cha H, Chung CY, Lee K, Park MS. Effect of metallic tools on scattered radiation dose during the use of C-arm fluoroscopy in orthopaedic surgery. JOURNAL OF RADIATION RESEARCH 2019; 60:1-6. [PMID: 30247685 PMCID: PMC6373686 DOI: 10.1093/jrr/rry073] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/16/2018] [Revised: 06/27/2018] [Indexed: 06/08/2023]
Abstract
This study investigated the effect of metallic tools on the scattered radiation dose delivered to surgeons' radiosensitive organs while simulating hip surgery using C-arm fluoroscopy. Two phantoms, a pelvis and a Rando phantom, were used to simulate a patient and a surgeon in this study. Photoluminescence dosimeters were inserted into the Rando phantom in the positions of the eye, thyroid and gonad. A drill was positioned above the hip of the pelvis phantom or beside the pelvis phantom of the same height. For each drill location, the scattered radiation dose was measured when the angle to the operator phantom was 45°; this was repeated when the angle was 90°. The scattered radiation doses to the eye, thyroid and gonad when the drill was placed beside the pelvis phantom with 90° angulation to the operator phantom were significantly lower than the reference values and those when the drill was placed beside the pelvis phantom at a 45° angulation to the operator phantom. The scattered radiation doses to the eye and thyroid when the drill was placed above the hip were significantly lower than the references values. Of the four different scenarios, the scattered radiation doses to the eye, thyroid and gonad were lowest when the drill was placed beside the pelvis phantom with 90° angulation. This study showed that the scattered radiation doses to radiosensitive organs were affected by the location and angle of the metallic tools in relation to the operator. Therefore, orthopedic surgeons should consider the effect of metallic tools on the scattered radiation dose during intraoperative use of C-arm fluoroscopy.
Collapse
Affiliation(s)
- Ki Hyuk Sung
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, 82 Gumi-ro 173 Beon-gil, Bundang-Gu, Sungnam, Gyeonggi, Korea
| | - Young-Jun Jung
- Department of Bio-convergence Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, Korea
| | - Hyemi Cha
- Department of Bio-convergence Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, Korea
| | - Chin Youb Chung
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, 82 Gumi-ro 173 Beon-gil, Bundang-Gu, Sungnam, Gyeonggi, Korea
| | - Kisung Lee
- Department of Bio-convergence Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, Korea
- School of Biomedical Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, Korea
| | - Moon Seok Park
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, 82 Gumi-ro 173 Beon-gil, Bundang-Gu, Sungnam, Gyeonggi, Korea
| |
Collapse
|
9
|
Xu W, Li J, Ye J, Yu J, Yu J, Zhang Z. Transesophageal echocardiography and fluoroscopy for percutaneous closure of atrial septal defects: A comparative study. Medicine (Baltimore) 2018; 97:e12891. [PMID: 30412086 PMCID: PMC6221610 DOI: 10.1097/md.0000000000012891] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
The aim of the study was to compare transesophageal echocardiography (TEE) and fluoroscopy for percutaneous atrial septal defect (ASD) closure.This was a retrospective analysis of children who underwent percutaneous ASD closure. The procedure was guided by TEE without fluoroscopy in 130 patients (TEE group) and by fluoroscopy in 163 patients (fluoroscopy group). Baseline demographic/clinical characteristics were recorded. Patients were followed until hospital discharge. Outcomes were procedure duration, peri/postoperative complications, hospital stay, and costs.The TEE and fluoroscopy groups showed no significant differences in age (71.7 ± 40.7 vs 62.5 ± 38.8 months), male/female ratio (54/76 vs 66/97), weight (22.0 ± 12.0 vs 20.1 ± 9.0 kg), ASD diameter (9.9 ± 4.2 vs 9.3 ± 3.9 cm), distances to the superior vena cava (13.4 ± 4.6 vs 13.3 ± 4.2 cm), inferior vena cava (13.4 ± 4.3 vs 13.9 ± 4.1 cm) and atrial septal roof (12.1 ± 4.0 vs 12.3 ± 3.2 cm), or atrial septal size (38.2 ± 6.2 vs 39.4 ± 26.6 cm); distance to the mitral valve was greater in the TEE group (13.2 ± 4.4 vs 11.3 ± 3.9 cm; P < .001). The TEE and fluoroscopy groups showed no significant differences in occlusion device size (14.3 ± 4.6 vs 13.8 ± 4.0 cm) or sheath size (8.7 ± 1.8 vs 8.7 ± 0.9 cm), but procedure duration was shorter in the TEE group (21.5 ± 14.6 vs 28.6 ± 10.9 minutes; P < .001). Postoperative fever (>38°C) occurred less frequently in the TEE group than in the fluoroscopy group (0.8% vs 9.2%; P < .001); there were no significant differences for the other complications. No patient had postoperative residual shunt, occlusion device shedding/displacement, or pericardial effusion. The TEE group had longer hospital stay (3.2 ± 0.6 vs 2.9 ± 0.6 days; P < .001) and higher procedure cost (29,687 ± 4218 vs 28,530 ± 1668 CNY (China Yuan); P = .002) than the fluoroscopy group.TEE-guided percutaneous ASD closure can be used as an alternative to fluoroscopy-guided procedures and avoids the use of radiation or contrast agents.
Collapse
|
10
|
Zhang Z, Zhao X, Wang YF. Dexmedetomidine for Transesophageal Echocardiography-Guided Percutaneous Closure of an Atrial Septal Defect in an Infant without Endotracheal Intubation. Chin Med J (Engl) 2018; 131:2137-2138. [PMID: 30127233 PMCID: PMC6111682 DOI: 10.4103/0366-6999.239317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
11
|
Yu J, Ma L, Ye J, Zhang Z, Li J, Yu J, Jiang G. Doubly committed ventricular septal defect closure using eccentric occluder via ultraminimal incision. Eur J Cardiothorac Surg 2018; 52:805-809. [PMID: 29156020 DOI: 10.1093/ejcts/ezx269] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2016] [Accepted: 06/28/2017] [Indexed: 11/14/2022] Open
Abstract
OBJECTIVES This study aimed to investigate the safety, feasibility and availability of doubly committed ventricular septal defect (DCVSD) closure via an ultraminimal intercostal incision under the guidance of transoesophageal echocardiography in children. METHODS From August 2014 to August 2016, 35 children with DCVSDs (≤5 mm in diameter) were enrolled in this study. A left parasternal ultraminimal intercostal incision (≤1 cm) and a pericardium hanging technique were employed without sternal incision. DCVSDs were closed through a short delivery sheath assembled with an eccentric occluder device. Transoesophageal echocardiography was used to guide and monitor the entire procedure. All patients were followed up. RESULTS All 35 children had complete closures with an operation success rate of 100%. The average size of DCVSDs was 3.50 ± 0.79 (range 2.2-5.0) mm, and the average device size was 5 ± 2 (range 4-9) mm. The average operation duration was 45.42 ± 11.77 (range 25-70) min, and the average hospital stay was 8 ± 2 (range 7-16) days. The median follow-up period was 17 months (range 6 months-2.5 years). Pre-existing aortic regurgitation disappeared after surgery in 1 patient and remained the same in 4 patients. No other complications were found during the operation or during follow-up. CONCLUSIONS Under transoesophageal echocardiography guidance, DCVSD closure using an eccentric occluder via an ultraminimal intercostal incision is feasible, safe and effective in children. The use of this approach is recommended.
Collapse
Affiliation(s)
- Jin Yu
- Department of Ultrasound Diagnosis, Children's Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Lianglong Ma
- Department of Cardiothoracic Surgery, Children's Hospital, Zhejiang University School of Medicine, Children's Hospital, Hangzhou, China
| | - Jingjing Ye
- Department of Ultrasound Diagnosis, Children's Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Zewei Zhang
- Department of Cardiothoracic Surgery, Children's Hospital, Zhejiang University School of Medicine, Children's Hospital, Hangzhou, China
| | - Jianhua Li
- Department of Cardiothoracic Surgery, Children's Hospital, Zhejiang University School of Medicine, Children's Hospital, Hangzhou, China
| | - Jiangen Yu
- Department of Cardiothoracic Surgery, Children's Hospital, Zhejiang University School of Medicine, Children's Hospital, Hangzhou, China
| | - Guoping Jiang
- Department of Ultrasound Diagnosis, Children's Hospital, Zhejiang University School of Medicine, Hangzhou, China
| |
Collapse
|
12
|
Jones TP, Brennan PC, Ryan E. THE IMPACT OF DIGITAL TECHNOLOGY ON DOSE REDUCTION IN PAEDIATRIC CARDIAC CATHETERISATION WITHIN A LARGE METROPOLITAN CHILDREN'S HOSPITAL. RADIATION PROTECTION DOSIMETRY 2018; 179:358-363. [PMID: 29309695 DOI: 10.1093/rpd/ncx294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2017] [Accepted: 12/06/2017] [Indexed: 06/07/2023]
Abstract
This study examines the kerma-area product (PKA) levels from paediatric cardiac catheterisations at a major Children's Hospital over three different time periods in order to gain an understanding of the causation of dose variations over time and to present a model for dose reduction. A retrospective review of 1245 paediatric procedural records was undertaken. This cohort consisted of patients that were catheterised over a period from November 2007 to July 2009, October 2009 to November 2011 and January 2016 to December 2016. The age distribution was from newborn to 18 years. Archived (PKA) readings were retrieved and analysed. The 75th percentile PKA values for the specific age categories over time periods (1, 2, 3) were 0-30 days-(5.47, 1.37, 1.37) Gy cm2; 1-12 months-(6.42, 2.03, 1.06) Gy cm2; 1-3 years-(11.25, 3.20, 1.25) Gy cm2; 3-5 years-(12.65, 3.72, 2.88) Gy cm2; 5-10 years-(12.80, 8.53, 3.52) Gy cm2; 10-15 years-(27.92, 10.85, 2.97) Gy cm2; >15 years-(29.09, 27.81, 11.65) Gy cm2. Using newer imaging technologies, optimising dose reduction strategies and regular dose auditing can transform radiation dose delivery for paediatric x-ray examinations. Our centre provides a template for dose reduction success worldwide.
Collapse
Affiliation(s)
- T P Jones
- Medical Imaging Optimisation and Perception Group (MIOPeG), Discipline of Medical Radiation Sciences, Faculty of Health Science, University of Sydney, 75 East Street, Lidcombe NSW 2141, Australia
| | - P C Brennan
- Medical Imaging Optimisation and Perception Group (MIOPeG), Discipline of Medical Radiation Sciences, Faculty of Health Science, University of Sydney, 75 East Street, Lidcombe NSW 2141, Australia
| | - E Ryan
- Medical Imaging Optimisation and Perception Group (MIOPeG), Discipline of Medical Radiation Sciences, Faculty of Health Science, University of Sydney, 75 East Street, Lidcombe NSW 2141, Australia
| |
Collapse
|
13
|
Xu WZ, Shou XY, Li JH, Yu JG, Zhang ZW, Yu J, Ye JJ. Non-fluoroscopic percutaneous transcatheter closure of atrial septal defects in children under transesophageal echocardiographic guidance. World J Pediatr 2018; 14:378-382. [PMID: 30141110 PMCID: PMC6154211 DOI: 10.1007/s12519-018-0179-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2018] [Accepted: 07/30/2018] [Indexed: 10/29/2022]
Abstract
BACKGROUND This study sought to investigate the feasibility, safety and effectiveness of transcatheter closure of atrial septal defects (ASDs) under the guidance of transesophageal echocardiography (TEE) in children. METHODS We reviewed the medical records of patients who underwent percutaneous ASD closure at our center from August 2016 to December 2017. For a total of 88 patients who were identified as having a single-hole defect and were undergoing percutaneous transcatheter ASD closure, a procedure completely guided by TEE was performed. There were 31 male patients and 57 female patients. The patients' mean age was 60.09 ± 36.42 months (13-182 months), and their mean body weight was 20.16 ± 10.04 kg (9-77 kg). Patients were followed up by performing transthoracic echocardiography and obtaining chest X-rays and electrocardiograms. RESULTS The transcatheter closure of ASDs was successful in all patients. The mean ASD size was 11.58 ± 5.31 mm (3-28 mm), and the mean size of the occlusion device was 16.07 ± 5.29 mm (6-36 mm). The mean procedural times were 13.33 ± 2.82 minutes (6-16 minutes). The mean hospitalization costs were 27,259.66 ± 2507.04 RMB (25,200.00-33,911.45 RMB). The mean postoperative hospital stay was 3.22 ± 0.53 days (3-5 days). Residual shunt, occlusion device shedding or displacement, and pericardial effusion were not observed during or after the operation. CONCLUSION Percutaneous transcatheter ASD closure completely guided by TEE is a feasible, safe, non-invasive and easy procedure.
Collapse
Affiliation(s)
- Wei-Ze Xu
- 0000 0004 1759 700Xgrid.13402.34Heart Center, Children’s Hospital, Zhejiang University School of Medicine, Hangzhou, 310052 China
| | - Xin-Yi Shou
- 0000 0001 0348 3990grid.268099.cWenzhou Medical University, Wenzhou, 325035 China
| | - Jian-Hua Li
- 0000 0004 1759 700Xgrid.13402.34Heart Center, Children’s Hospital, Zhejiang University School of Medicine, Hangzhou, 310052 China
| | - Jian-Gen Yu
- 0000 0004 1759 700Xgrid.13402.34Heart Center, Children’s Hospital, Zhejiang University School of Medicine, Hangzhou, 310052 China
| | - Ze-Wei Zhang
- 0000 0004 1759 700Xgrid.13402.34Heart Center, Children’s Hospital, Zhejiang University School of Medicine, Hangzhou, 310052 China
| | - Jin Yu
- 0000 0004 1759 700Xgrid.13402.34Heart Center, Children’s Hospital, Zhejiang University School of Medicine, Hangzhou, 310052 China
| | - Jing-Jing Ye
- Heart Center, Children's Hospital, Zhejiang University School of Medicine, Hangzhou, 310052, China.
| |
Collapse
|
14
|
Gould R, McFadden SL, Hughes CM. Radiation dose in paediatric cardiac catheterisation: A systematic literature review. Radiography (Lond) 2017; 23:358-364. [PMID: 28965901 DOI: 10.1016/j.radi.2017.02.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2016] [Revised: 02/01/2017] [Accepted: 02/03/2017] [Indexed: 12/23/2022]
Abstract
OBJECTIVES It is believed that children are more sensitive to ionising radiation than adults. This work reviewed the reported radiation dose estimates for paediatric cardiac catheterisation. A systematic literature review was performed by searching healthcare databases for studies reporting radiation dose using predetermined key words relating to children having cardiac catheterisation. The quality of publications was assessed using relevant Critical Appraisal Skills Programme questions and their reported radiation exposures were evaluated. KEY FINDINGS It is only in recent years that larger cohort observations have been undertaken. Although radiation dose from paediatric cardiac catheterisation has decreased in recent years, the literature indicated that it remains varied and potentially substantial. CONCLUSION Standardisation of weight categories and procedure types such as those recommended by the PiDRL project could help compare current and future radiation dose estimates.
Collapse
Affiliation(s)
- R Gould
- Institute of Nursing and Health Research, Ulster University, Jordanstown Campus, Shore Road, Newtownabbey, BT37 OQB, United Kingdom.
| | - S L McFadden
- Institute of Nursing and Health Research, Ulster University, Jordanstown Campus, Shore Road, Newtownabbey, BT37 OQB, United Kingdom
| | - C M Hughes
- Institute of Nursing and Health Research, Ulster University, Jordanstown Campus, Shore Road, Newtownabbey, BT37 OQB, United Kingdom
| |
Collapse
|
15
|
Gould R, McFadden SL, Sands AJ, McCrossan BA, Horn S, Prise KM, Doyle P, Hughes CM. Removal of scatter radiation in paediatric cardiac catheterisation: a randomised controlled clinical trial. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2017; 37:742-760. [PMID: 28721947 DOI: 10.1088/1361-6498/aa80a4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
OBJECTIVE This study sought to determine if DNA integrity was compromised by ionising radiation from paediatric cardiac catheterisations and if dose optimisation techniques allowed DNA integrity to be maintained. MATERIALS AND METHODS Children were imaged using either: (i) an anti-scatter grid (current departmental protocol), (ii) no anti-scatter grid or, (iii) no anti-scatter grid and a 15 cm air-gap between the child and the x-ray detector. Dose area product and image quality were assessed, lifetime attributable cancer risk estimates were calculated and DNA double-strand breakages quantified using the γH2AX assay. RESULTS Consent was obtained from 70 parents/guardians/children. Image quality was sufficient for each procedure performed. Removal of the anti-scatter grid resulted in dose reductions of 20% (no anti-scatter grid) and 30% (15 cm air-gap), DNA double-strand break reductions of 30% (no anti-scatter grid) and 20% (15 cm air-gap) and a reduction of radiation-induced cancer mortality risk of up to 45%. CONCLUSION Radiation doses received during paediatric cardiac catheterisation procedures resulted in a significant increase in DNA damage while maintaining acceptable image quality and diagnostic efficacy. It is feasible to remove the anti-scatter grid resulting in a reduction in DNA damage to the patient. The γH2AX assay may be used for assessment of dose optimisation strategies in children.
Collapse
Affiliation(s)
- Richard Gould
- Institute of Nursing and Health Research, Ulster University, Jordanstown Campus, Shore Road, Newtownabbey, United Kingdom
| | | | | | | | | | | | | | | |
Collapse
|
16
|
Ubeda C, Miranda P, Vano E, Nocetti D, Manterola C. Organ and effective doses from paediatric interventional cardiology procedures in Chile. Phys Med 2017; 40:95-103. [PMID: 28743619 DOI: 10.1016/j.ejmp.2017.07.015] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2017] [Revised: 06/26/2017] [Accepted: 07/16/2017] [Indexed: 10/19/2022] Open
Abstract
The aim of this study was to present the results of organ and effective doses for paediatric patients for different types of interventional cardiology procedures for age and weight groups, derived from a patient dosimetry pilot programme carried out in Chile, under the auspices of the International Atomic Energy Agency. Over seven years, a retrospective collection of demographic and patient dose data was obtained: age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time, dose-area product (DAP) and cumulative dose at patient entrance reference point. Monte Carlo software was used to calculate organ and effective doses. 1506 procedures were divided into four age and seven weight groups. Organ doses (median values) for diagnostic and therapeutic procedures were: active bone marrow 0.90 and 0.64mGy; heart 1.99 and 1.46mGy; lungs 3.56 and 2.59mGy; thyroid 1.27 and 0.83; and breast (in the case of females) 1.78 and 1.36mGy. The ranges for effective doses (median values) and weight bands were 1.2-3.9mSv for diagnostic procedures and 1.0-2.5mSv for therapeutic procedures. The resulting conversion factors (median values) to estimate effective dose from DAP (in mSv/Gy.cm2) were: 1.70; 0.89; 0.58; and 0.40, for age groups of <1year, 1-<5years, 5-<10years and 10-<16years, respectively. The obtained set of dose values will enable comparisons with other imaging procedures (comparing the same age bands) for justification and optimization purposes.
Collapse
Affiliation(s)
- Carlos Ubeda
- Medical Technology Department, Radiological Sciences Center, Health Sciences Faculty, Tarapaca University, Arica, Chile.
| | - Patricia Miranda
- Hemodynamic Department, Cardiovascular Service, Luis Calvo Mackenna Hospital, Santiago, Chile
| | - Eliseo Vano
- Radiology Department, Faculty of Medicine, Complutense University and IdIS, San Carlos Hospital, 28040 Madrid, Spain
| | - Diego Nocetti
- Medical Technology Department, Radiological Sciences Center, Health Sciences Faculty, Tarapaca University, Arica, Chile
| | - Carlos Manterola
- Hepatobiliary Surgery Unit, Department of Surgery, Faculty of Medicine, Universidad de la Frontera, Temuco, Chile
| |
Collapse
|
17
|
Harbron RW, Dreuil S, Bernier MO, Pearce MS, Thierry-Chef I, Chapple CL, Baysson H. Patient radiation doses in paediatric interventional cardiology procedures: a review. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2016; 36:R131-R144. [PMID: 27893455 DOI: 10.1088/0952-4746/36/4/r131] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A large number of investigations into the radiation doses from x-ray guided interventional cardiology procedures in children have been carried out in recent years. A review was conducted of these studies, gathering data on kerma area product (P KA), fluoroscopic screening time (FT), air kerma, and estimates of effective dose and organ doses. The majority of studies focus on P KA and FT with no estimation of dose to the patient. A greater than ten-fold variation in average P KA was found between different studies, even where data were stratified by patient age or weight. Typical values of P KA were 0.6-10 Gy · cm2 (<1 year/10 kg), 1.5-30 Gy · cm2 (1-5 years), 2-40 Gy · cm2 (5-10 years), 5-100 Gy · cm2 (10-16 years) and 10-200 Gy · cm2 (>16 years). P KA was lowest for heart biopsy (0.3-10 Gy · cm2 for all ages combined) and atrial septostomy (0.4-4.0 Gy · cm2), and highest for pulmonary artery angioplasty (1.5-35 Gy · cm2) and right ventricular outflow tract dilatation (139 Gy · cm2). Most estimates of patient dose were in the form of effective dose (typically 3-15 mSv) which is of limited usefulness in individualised risk assessment. Few studies estimated organ doses. Despite advances in radiation protection, recent publications have reported surprisingly large doses, as represented by P KA and air kerma. There is little indication of a fall in these dose indicators over the last 15 years. Nor is there much suggestion of a fall in doses associated with the use of flat panel detectors, as opposed to image intensifiers. An assessment of the impact of radiation dose in the context of overall patient outcome is required.
Collapse
Affiliation(s)
- R W Harbron
- Institute of Health and Society, Newcastle University, Royal Victoria Infirmary, Queen Victoria Road, Newcastle-upon-Tyne, NE1 4LP, UK. NIHR Health Protection Research Unit in Chemical and Radiation Threats and Hazards, Newcastle University, Newcastle-upon-Tyne, UK
| | | | | | | | | | | | | |
Collapse
|
18
|
Song S, Liu C, Zhang M. Radiation dose and mortality risk to children undergoing therapeutic interventional cardiology. Acta Radiol 2015; 56:867-72. [PMID: 25024440 DOI: 10.1177/0284185114542459] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2013] [Accepted: 06/12/2014] [Indexed: 11/17/2022]
Abstract
BACKGROUND Children undergoing interventional cardiology procedures deserve special concern due to the greater radiation sensitivity of their tissues and more remaining years of life during which a radiation-induced cancer may develop. PURPOSE To determine the patient radiation dose for pediatric therapeutic interventional cardiology and to estimate the patient effective dose and lifetime mortality risk to children associated with five common procedures. MATERIAL AND METHODS Ninety children with congenital heart defects undergoing interventional therapy were enrolled in this study. Data regarding fluoroscopy and radiography time, dose-area product (DAP) and peak skin dose (PSD) for each case were measured. Patients were divided into five groups. The patient effective dose (E) was calculated using a multiplicative model of ICRP 60. The overall lifetime mortality risk was evaluated using appropriate risk coefficients. RESULTS The mean, median, standard deviation, and range of time, PSD, DAP, and E were presented for the five study groups. When these metrics were considered, there were wide variations for different cases within the same group and statistically significant differences between the five groups. The PSD correlated significantly with DAP (Pearson r = 0.70; P < 0.01), but the correlation in individual cases was poor. For all cases, the range of E was found to be between 0.44 and 66.7 mSv. The corresponding risk of lifetime mortality was 1.16 per thousand. CONCLUSION The current study provides overall data on the time, PSD, E, and lifetime mortality risk for pediatric therapeutic interventional cardiology. Radio frequency ablation showed the highest radiation risk.
Collapse
Affiliation(s)
- Shanjun Song
- Interventional Department, Liaocheng People’s Hospital, Liaocheng, Shandong, PR China
| | - Chenzhi Liu
- Interventional Department, Liaocheng People’s Hospital, Liaocheng, Shandong, PR China
| | - Menglong Zhang
- Shandong Medical Imaging Research Institute, Jinan, PR China
| |
Collapse
|
19
|
Radiation safety protocol using real-time dose reporting reduces patient exposure in pediatric electrophysiology procedures. Pediatr Cardiol 2014; 35:1116-23. [PMID: 24801673 DOI: 10.1007/s00246-014-0904-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2013] [Accepted: 03/25/2014] [Indexed: 12/21/2022]
Abstract
Radiation exposure during pediatric catheterization is significant. We sought to describe radiation exposure and the effectiveness of radiation safety protocols in reducing exposure during catheter ablations with electrophysiology studies in children and patients with congenital heart disease. We additionally sought to identify at-risk patients. We retrospectively reviewed all interventional electrophysiology procedures performed from April 2009 to September 2011 (6 months preceding intervention, 12 months following implementation of initial radiation safety protocol, and 8 months following implementation of modified protocol). The protocols consisted of low pulse rate fluoroscopy settings, operator notification of skin entrance dose every 1,000 mGy, adjusting cameras by >5 at every 1,000 mGy, and appropriate collimation. The cohort consisted of 291 patients (70 pre-intervention, 137 after initial protocol implementation, 84 after modified protocol implementation) at a median age of 14.9 years with congenital heart disease present in 11 %. Diagnoses included atrioventricular nodal reentrant tachycardia (25 %), atrioventricular reentrant tachycardia (61 %), atrial tachycardias (12 %), and ventricular tachycardia (2 %). There were no differences between groups based on patient, arrhythmia, and procedural characteristics. Following implementation of the protocols, there were significant reductions in all measures of radiation exposure: fluoroscopy time (17.8 %), dose area product (80.2 %), skin entry dose (81.0 %), and effective dose (76.9 %), p = 0.0001. Independent predictors of increased radiation exposure included larger patient weight, longer fluoroscopy time, and lack of radiation safety protocol. Implementation of a radiation safety protocol for pediatric and congenital catheter ablations can drastically reduce radiation exposure to patients without affecting procedural success.
Collapse
|
20
|
Barnaoui S, Rehel JL, Baysson H, Boudjemline Y, Girodon B, Bernier MO, Bonnet D, Aubert B. Local reference levels and organ doses from pediatric cardiac interventional procedures. Pediatr Cardiol 2014; 35:1037-45. [PMID: 24651982 DOI: 10.1007/s00246-014-0895-5] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2013] [Accepted: 02/28/2014] [Indexed: 10/25/2022]
Abstract
Interventional cardiology (IC) procedures can be responsible for relatively high radiation doses compared to conventional radiology especially for young patients. The aim of this study was to assess current exposure levels in a French reference centre of pediatric IC. Dosimetric data including dose area product (DAP), fluoroscopy time (FT) and number of cine frame (NF) were analysed taking into account patient weight. Doses to the lungs, esophagus, breast and thyroid were evaluated using anthropomorphic phantoms and thermoluminescent dosimeters. Finally, effective doses (E) were calculated using DAP and conversion factors calculated with PCXMC 2.0 software. 801 IC procedures performed between 2010 and 2011 were analysed. Large variations were observed for DAP, FT and NF values for a given procedure and a given weight group. The assessment of organ doses showed high levels of dose to the lungs and esophagus especially in new-born babies. For diagnostic procedures, E varied from 0.3 to 23 mSv with a mean value of 4.8 mSv and for therapeutic procedures, values ranged from 0.1 to 48.4 mSv with a mean value of 7.3 mSv. The highest values were recorded for angioplasty procedures (mean 13 mSv, range 0.6-48.4 mSv). The increasing use of IC in pediatric population stresses the need of setting up reference levels and keeping doses to children as low as possible.
Collapse
Affiliation(s)
- S Barnaoui
- Medical Radiation Protection Expertise Unit, Institute of Radioprotection and Nuclear Safety, Fontenay-aux-Roses, France
| | | | | | | | | | | | | | | |
Collapse
|
21
|
Garg N, Walia R, Neyaz Z, Kumar S. Computed tomographic versus catheterization angiography in tetralogy of Fallot. Asian Cardiovasc Thorac Ann 2014; 23:164-75. [PMID: 24912609 DOI: 10.1177/0218492314538844] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
AIM To compare multidetector computed tomographic angiography with the gold standard cardiac catheterization and angiography in tetralogy of Fallot. METHODS In 40 consecutive patients over 5 years of age with tetralogy of Fallot, multidetector computed tomographic angiography and catheterization angiography studies were compared for intracardiac anatomy, pulmonary anatomy and indices, coronaries and collaterals. Safety parameters, relative advantages and limitations were also analyzed. RESULTS All catheterization studies required hospitalization whereas all tomographic studies were performed as outpatient procedures. The need for sedation and amount of contrast used were significantly greater in catheterization than in tomographic studies. Complications noted during catheterization were access site complications in 4 patients, cyanotic spells in 2, transient complete heart block requiring temporary pacing in 2, and air embolism in one. No complication was observed during tomographic studies. All tomographic studies were adequate, but 2 catheterization studies were inadequate. Ventricular septal defects, aortic override, level of right ventricular outflow tract obstruction, and pulmonary artery anatomy were equally assessed by both imaging modalities. However, tomographic studies missed additional small muscular ventricular septal defects. There was a linear correlation between tomographic and catheterization studies for pulmonary annulus size, artery sizes, Z-score, and Nakata index. There was complete concordance with respect to side of aortic arch and detection of collaterals. Coronary anatomy was better delineated in tomographic studies. CONCLUSIONS For preoperative evaluation of tetralogy of Fallot patients, multidetector computed tomographic angiography can be used as a reliable noninvasive alternative to cardiac catheterization angiography.
Collapse
Affiliation(s)
- Naveen Garg
- Department of Cardiology, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, India
| | - Rohit Walia
- Department of Radiology, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, India
| | - Zafar Neyaz
- Department of Radiology, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, India
| | - Sunil Kumar
- Department of Radiology, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, India
| |
Collapse
|
22
|
Wang K, Pan X, Tang Q, Pang Y. Catheterization therapy vs surgical closure in pediatric patients with patent ductus arteriosus: a meta-analysis. Clin Cardiol 2014; 37:188-94. [PMID: 24395607 DOI: 10.1002/clc.22238] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2013] [Revised: 11/27/2013] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Patent ductus arteriosus (PDA) remains a common congenital heart disease in pediatric patients, and the new trend of catheterization therapy is still associated with some potential risks and complications. HYPOTHESIS Compared with surgical closure, the clinical effect of catheterization therapy in pediatric PDA patients requires meta-analysis. METHODS A systematic literature search of PubMed, Cochrane Library, Embase, Science Citation Index, Web of Science, and the Chinese Biomedicine literature database was conducted. Eligible studies included controlled trials of pediatric PDA patients receiving catheterization therapy vs surgical closure. Relative risks (RRs), standard mean differences, and 95% confidence intervals (CIs) were calculated and heterogeneity was assessed with the I(2) test. RESULTS Seven studies with a total of 810 patients met the inclusion criteria. Catheterization therapy neither significantly increased the primary success rate (RR: 0.92, 95% CI: 0.82-1.03, P = 0.16) nor reduced the total postprocedure complications (RR: 0.74, 95% CI: 0.44-1.25, P = 0.26) and blood transfusion (RR: 1.10, 95% CI: 0.16-7.67, P = 0.93). Catheterization was associated with a statistically significant increase in residual shunts (RR: 5.19, 95% CI: 1.41-19.20, P = 0.01) and reduction in length of hospital stay (standard mean difference: -1.66, 95% CI: -2.65 to -0.67, P = 0.001). CONCLUSIONS Catheterization therapy in pediatric PDA patients did not show a significant advantage in primary success rate, total complications, or blood transfusion, but it was associated with increase in residual shunts and reduction in length of hospital stay.
Collapse
Affiliation(s)
- Kai Wang
- Department of Pediatrics, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi Autonomous Region, China
| | | | | | | |
Collapse
|
23
|
Baysson H, Réhel JL, Boudjemline Y, Petit J, Girodon B, Aubert B, Laurier D, Bonnet D, Bernier MO. Risk of cancer associated with cardiac catheterization procedures during childhood: a cohort study in France. BMC Public Health 2013; 13:266. [PMID: 23521893 PMCID: PMC3621730 DOI: 10.1186/1471-2458-13-266] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2013] [Accepted: 03/08/2013] [Indexed: 12/03/2022] Open
Abstract
BACKGROUND Radiation can be used effectively for diagnosis and medical treatment, but it can also cause cancers later on. Children with congenital heart disease frequently undergo cardiac catheterization procedures for diagnostic or treatment purposes. Despite the clear clinical benefit to the patient, the complexity of these procedures may result in high cumulative radiation exposure. Given children's greater sensitivity to radiation and the longer life span during which radiation health effects can develop, an epidemiological cohort study is being launched in France to evaluate the risks of leukaemia and solid cancers in this specific population. METHODS/DESIGN The study population will include all children who have undergone at least one cardiac catheterization procedure since 2000 and were under 10 years old and permanent residents of France at the time of the procedure. Electronically stored patient records from the departments of paediatric cardiology of the French national network for complex congenital heart diseases (M3C) are being searched to identify the children to be included. The minimum dataset will comprise: identification of the subject (file number in the centre or department, full name, sex, date and place of birth), and characteristics of the intervention (date, underlying disease, type of procedure, technical details, such as fluoroscopy time and dose area product, (DAP), which are needed to reconstruct the doses received by each child). The cohort will be followed up through linkage with the two French paediatric cancer registries, which have recorded all cases of childhood leukaemia and solid cancers in France since 1990 and 2000, respectively. Radiation exposure will be estimated retrospectively for each child. 4500 children with catherizations between 2000 and 2011 have been already included in the cohort, and recruitment is ongoing at the national level. The study is expected to finally include a total of 8000 children. DISCUSSION This French cohort study is specifically designed to provide further knowledge about the potential cancer risks associated with paediatric cardiac catheterization procedures. It will also provide new information on typical dose levels associated with these procedures in France. Finally, it should help improve awareness of the importance of radiation protection in these procedures.
Collapse
Affiliation(s)
- Helene Baysson
- Institut de Radioprotection et de Sûreté Nucléaire, PRP-HOM, SRBE, BP 17, Fontenay aux Roses, France
| | - Jean Luc Réhel
- Institut de Radioprotection et de Sûreté Nucléaire, PRP-HOM, SRBE, BP 17, Fontenay aux Roses, France
| | - Younes Boudjemline
- Centre de Référence Malformations Cardiaques Congénitales Complexes, M3C, Hôpital Necker-Enfants malades, AP-HP, Université Paris Descartes, Sorbonne Paris Cité, Paris, France
| | - Jerôme Petit
- Centre de Référence Malformations Cardiaques Congénitales Complexes, M3C, Centre Chirurgical Marie Lannelongue, Le Plessis Robinson, France
| | - Brigitte Girodon
- Centre de Référence Malformations Cardiaques Congénitales Complexes, M3C, Hôpital Necker-Enfants malades, AP-HP, Université Paris Descartes, Sorbonne Paris Cité, Paris, France
| | - Bernard Aubert
- Institut de Radioprotection et de Sûreté Nucléaire, PRP-HOM, SRBE, BP 17, Fontenay aux Roses, France
| | - Dominique Laurier
- Institut de Radioprotection et de Sûreté Nucléaire, PRP-HOM, SRBE, BP 17, Fontenay aux Roses, France
| | - Damien Bonnet
- Centre de Référence Malformations Cardiaques Congénitales Complexes, M3C, Hôpital Necker-Enfants malades, AP-HP, Université Paris Descartes, Sorbonne Paris Cité, Paris, France
| | - Marie-Odile Bernier
- Institut de Radioprotection et de Sûreté Nucléaire, PRP-HOM, SRBE, BP 17, Fontenay aux Roses, France
| |
Collapse
|
24
|
Yakoumakis E, Kostopoulou H, Makri T, Dimitriadis A, Georgiou E, Tsalafoutas I. Estimation of radiation dose and risk to children undergoing cardiac catheterization for the treatment of a congenital heart disease using Monte Carlo simulations. Pediatr Radiol 2013; 43:339-46. [PMID: 23093098 DOI: 10.1007/s00247-012-2510-3] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2012] [Revised: 07/19/2012] [Accepted: 08/29/2012] [Indexed: 10/27/2022]
Abstract
BACKGROUND Children diagnosed with congenital heart disease often undergo cardiac catheterization for their treatment, which involves the use of ionizing radiation and therefore a risk of radiation-induced cancer. OBJECTIVE The purpose of this study was to calculate the effective and equivalent organ doses (H(T)) in those children and estimate the risk of exposure-induced death. MATERIALS AND METHODS Fifty-three children were divided into three groups: atrial septal defect (ASD), ventricular septal defect (VSD) and patent ductus arteriosus (PDA). In all procedures, the exposure conditions and the dose-area product meters readings were recorded for each individual acquisition. Monte Carlo simulations were run using the PCXMC 2.0 code and mathematical phantoms simulating a child's anatomy. The H(T) values to all irradiated organs and the resulting E and risk of exposure-induced death values were calculated. RESULTS The average dose-area product values were, respectively, 40 ± 12 Gy·cm(2) for the ASD, 17.5 ± 0.7 Gy·cm(2) for the VSD and 9.5 ± 1 Gy·cm(2) for the PDA group. The average E values were 40 ± 12, 22 ± 2.5 and 17 ± 3.6 mSv for ASD, VSD and PDA groups, respectively. The respective estimated risk of exposure-induced death values per procedure were 0.109, 0.106 and 0.067%. CONCLUSION Cardiac catheterizations in children involve a considerable risk for radiation-induced cancer that has to be further reduced.
Collapse
Affiliation(s)
- Emmanuel Yakoumakis
- Medical Physics Department, Medical School, University of Athens, 75 Mikras Asias, 11527, Athens, Greece
| | | | | | | | | | | |
Collapse
|
25
|
Cardiac Magnetic Resonance and the Need for Routine Cardiac Catheterization in Single Ventricle Patients Prior to Fontan: A Comparison of 3 Groups. J Am Coll Cardiol 2012; 60:1094-102. [DOI: 10.1016/j.jacc.2012.06.021] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2012] [Revised: 06/19/2012] [Accepted: 06/26/2012] [Indexed: 11/23/2022]
|
26
|
Schubert S, Kainz S, Peters B, Berger F, Ewert P. Interventional closure of atrial septal defects without fluoroscopy in adult and pediatric patients. Clin Res Cardiol 2012; 101:691-700. [PMID: 22454137 DOI: 10.1007/s00392-012-0445-1] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2011] [Accepted: 03/14/2012] [Indexed: 12/16/2022]
Abstract
BACKGROUND Interventional closure of atrial septal defects (ASDs) with a transcatheter device is the preferred strategy in children and adults. This procedure has been proven in numerous studies, but X-ray and contrast agent exposure is still a major side effect. The aim of this study was to clarify whether the interventional closure of ASDs is possible and safe if it is guided by transesophageal echocardiography (TEE) alone. METHODS AND RESULTS We retrospectively selected and studied pediatric and adult patients with interventional closure of ASDs at the Deutsches Herzzentrum Berlin (DHZB) without fluoroscopy between 1999 and 2010. We included 330 out of 1,605 patients; 254 had an ASD II, 30 a PFO and 46 multiperforated atrial septum. Median age was 8.92 (0.96-76.3) years and median body weight 32.6 (8.3-156) kg. Median stretched defect size was 13 (5-29) mm. Median procedure time was 50 (20-170) min. Closure was performed in the majority of patients with the Amplatzer(®) septal occluder or Amplatzer(®) PFO occluder. The procedure succeeded in 98.2 % of cases and closure rate was 94.9 % after 48 h. Complication rate was low and procedure time was similar to that necessary with studies using fluoroscopy. CONCLUSION Interventional closure of ASDs is safe and effective if guided with TEE alone. The results can compete with those with the use of fluoroscopy. TEE-guided closure of ASD should be considered in more catheter laboratories to avoid unnecessary radiation exposure for the patient and the examiner.
Collapse
Affiliation(s)
- Stephan Schubert
- Department of Congenital Heart Disease and Pediatric Cardiology, Deutsches Herzzentrum Berlin, Berlin, Germany.
| | | | | | | | | |
Collapse
|
27
|
Ashok Kasar P, Ravikumar R, Varghese R, Kotecha M, Vimala J, Kumar RNS. Computed tomographic angiography in tetralogy of Fallot. Asian Cardiovasc Thorac Ann 2011; 19:324-32. [DOI: 10.1177/0218492311419164] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Echocardiography is often inadequate for imaging tetralogy of Fallot, prompting cineangiography. This study prospectively evaluated multidetector computed tomographic angiography for preoperative evaluation of tetralogy of Fallot in 112 consecutive patients. Forty-eight had nonconfluent or hypoplastic pulmonary arteries (mean z-score, −2; range, −11.1–0.13) permitting only palliative or no surgery; 64 had adequate pulmonary artery anatomy (mean z-score, 0.59; range,−2.53–3.4) allowing total repair. The surgical data of 50 patients who underwent total correction were compared with transthoracic echocardiography and multidetector computed tomographic angiography findings. Multidetector computed tomographic angiography tended to reveal unsuspected collaterals and coronary abnormalities besides outlining the right ventricular outflow tract and pulmonary artery branches. The branch pulmonary artery diameter z-score was the most important determinant of surgical strategy, with the worst figures being associated with no surgical options or palliative surgery, and the best figures leading to corrective surgery. The mean radiation dose was 3.45 mSv. Multidetector computed tomographic angiography is a powerful supplement to echocardiography in the preoperative evaluation of tetralogy of Fallot.
Collapse
Affiliation(s)
| | | | - Roy Varghese
- Department of Pediatric Cardiac Surgery, The Madras Medical Mission, Chennai, India
| | - Monika Kotecha
- Department of Pediatric Cardiology, The Madras Medical Mission, Chennai, India
| | - Jesudian Vimala
- Department of Pediatric Cardiology, The Madras Medical Mission, Chennai, India
| | | |
Collapse
|
28
|
Vastel-Amzallag C, Le Bret E, Paul JF, Lambert V, Rohnean A, El Fassy E, Sigal-Cinqualbre A. Diagnostic accuracy of dual-source multislice computed tomographic analysis for the preoperative detection of coronary artery anomalies in 100 patients with tetralogy of Fallot. J Thorac Cardiovasc Surg 2011; 142:120-6. [DOI: 10.1016/j.jtcvs.2010.11.016] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2010] [Revised: 10/15/2010] [Accepted: 11/05/2010] [Indexed: 12/18/2022]
|
29
|
Reduction of Radiation Doses in Cardiac Imaging, Part I: Minimally Invasive Cardiovascular Procedures. CURRENT CARDIOVASCULAR IMAGING REPORTS 2011. [DOI: 10.1007/s12410-011-9077-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|