1
|
Sanmartín-Matalobos J, Bermejo-Barrera P, Aboal-Somoza M, Fondo M, García-Deibe AM, Corredoira-Vázquez J, Alves-Iglesias Y. Semiconductor Quantum Dots as Target Analytes: Properties, Surface Chemistry and Detection. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:2501. [PMID: 35889725 PMCID: PMC9318497 DOI: 10.3390/nano12142501] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Revised: 07/17/2022] [Accepted: 07/19/2022] [Indexed: 02/04/2023]
Abstract
Since the discovery of Quantum Dots (QDs) by Alexey I. Ekimov in 1981, the interest of researchers in that particular type of nanomaterials (NMs) with unique optical and electrical properties has been increasing year by year. Thus, since 2009, the number of scientific articles published on this topic has not been less than a thousand a year. The increasing use of QDs due to their biomedical, pharmaceutical, biological, photovoltaics or computing applications, as well as many other high-tech uses such as for displays and solid-state lighting (SSL), has given rise to a considerable number of studies about its potential toxicity. However, there are a really low number of reported studies on the detection and quantification of QDs, and these include ICP-MS and electrochemical analysis, which are the most common quantification techniques employed for this purpose. The knowledge of chemical phenomena occurring on the surface of QDs is crucial for understanding the interactions of QDs with species dissolved in the dispersion medium, while it paves the way for a widespread use of chemosensors to facilitate its detection. Keeping in mind both human health and environmental risks of QDs as well as the scarcity of analytical techniques and methodological approaches for their detection, the adaptation of existing techniques and methods used with other NMs appears necessary. In order to provide a multidisciplinary perspective on QD detection, this review focused on three interrelated key aspects of QDs: properties, surface chemistry and detection.
Collapse
Affiliation(s)
- Jesús Sanmartín-Matalobos
- Coordination and Supramolecular Chemistry Group (SupraMetal), Department of Inorganic Chemistry, Faculty of Chemistry, Institute of Materials (iMATUS), Universidade de Santiago de Compostela, Avenida das Ciencias s/n, 15782 Santiago de Compostela, Spain; (M.F.); (J.C.-V.); (Y.A.-I.)
| | - Pilar Bermejo-Barrera
- Trace Element, Speciation and Spectroscopy Group (GETEE), Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, Institute of Materials (iMATUS), Universidade de Santiago de Compostela, Avenida das Ciencias s/n, 15782 Santiago de Compostela, Spain; (P.B.-B.); (M.A.-S.)
| | - Manuel Aboal-Somoza
- Trace Element, Speciation and Spectroscopy Group (GETEE), Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, Institute of Materials (iMATUS), Universidade de Santiago de Compostela, Avenida das Ciencias s/n, 15782 Santiago de Compostela, Spain; (P.B.-B.); (M.A.-S.)
| | - Matilde Fondo
- Coordination and Supramolecular Chemistry Group (SupraMetal), Department of Inorganic Chemistry, Faculty of Chemistry, Institute of Materials (iMATUS), Universidade de Santiago de Compostela, Avenida das Ciencias s/n, 15782 Santiago de Compostela, Spain; (M.F.); (J.C.-V.); (Y.A.-I.)
| | - Ana M. García-Deibe
- Coordination and Supramolecular Chemistry Group (SupraMetal), Department of Inorganic Chemistry, Faculty of Chemistry, Institute of Materials (iMATUS), Universidade de Santiago de Compostela, Avenida das Ciencias s/n, 15782 Santiago de Compostela, Spain; (M.F.); (J.C.-V.); (Y.A.-I.)
| | - Julio Corredoira-Vázquez
- Coordination and Supramolecular Chemistry Group (SupraMetal), Department of Inorganic Chemistry, Faculty of Chemistry, Institute of Materials (iMATUS), Universidade de Santiago de Compostela, Avenida das Ciencias s/n, 15782 Santiago de Compostela, Spain; (M.F.); (J.C.-V.); (Y.A.-I.)
| | - Yeneva Alves-Iglesias
- Coordination and Supramolecular Chemistry Group (SupraMetal), Department of Inorganic Chemistry, Faculty of Chemistry, Institute of Materials (iMATUS), Universidade de Santiago de Compostela, Avenida das Ciencias s/n, 15782 Santiago de Compostela, Spain; (M.F.); (J.C.-V.); (Y.A.-I.)
- Trace Element, Speciation and Spectroscopy Group (GETEE), Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, Institute of Materials (iMATUS), Universidade de Santiago de Compostela, Avenida das Ciencias s/n, 15782 Santiago de Compostela, Spain; (P.B.-B.); (M.A.-S.)
| |
Collapse
|
2
|
Freitas M, Nouws HPA, Delerue-Matos C. Voltammetric Immunosensor to Track a Major Peanut Allergen (Ara h 1) in Food Products Employing Quantum Dot Labels. BIOSENSORS 2021; 11:426. [PMID: 34821642 PMCID: PMC8615361 DOI: 10.3390/bios11110426] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Revised: 10/25/2021] [Accepted: 10/27/2021] [Indexed: 05/25/2023]
Abstract
Tracking unreported allergens in commercial foods can avoid acute allergic reactions. A 2-step electrochemical immunosensor was developed for the analysis of the peanut allergen Ara h 1 in a 1-h assay (<15 min hands-on time). Bare screen-printed carbon electrodes (SPCE) were used as transducers and monoclonal capture and detection antibodies were applied in a sandwich-type immunoassay. The short assay time was achieved by previously combining the target analyte and the detection antibody. Core/shell CdSe@ZnS Quantum Dots were used as electroactive label for the detection of the immunological interaction by differential pulse anodic stripping voltammetry. A linear range between 25 and 1000 ng·mL-1 (LOD = 3.5 ng·mL-1), an adequate precision of the method (Vx0 ≈ 6%), and a sensitivity of 23.0 nA·mL·ng-1·cm-2 were achieved. The immunosensor was able to detect Ara h 1 in a spiked allergen-free product down to 0.05% (m/m) of peanut. Commercial organic farming cookies and cereal and protein bars were tested to track and quantify Ara h 1. The results were validated by comparison with an ELISA kit.
Collapse
Affiliation(s)
| | - Henri P. A. Nouws
- REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, Rua Dr. António Bernardino de Almeida 431, 4200-072 Porto, Portugal; (M.F.); (C.D.-M.)
| | | |
Collapse
|
3
|
Printed Electrodes in Microfluidic Arrays for Cancer Biomarker Protein Detection. BIOSENSORS-BASEL 2020; 10:bios10090115. [PMID: 32906644 PMCID: PMC7559629 DOI: 10.3390/bios10090115] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 08/27/2020] [Accepted: 09/01/2020] [Indexed: 12/27/2022]
Abstract
Medical diagnostics is trending towards a more personalized future approach in which multiple tests can be digitized into patient records. In cancer diagnostics, patients can be tested for individual protein and genomic biomarkers that detect cancers at very early stages and also be used to monitor cancer progression or remission during therapy. These data can then be incorporated into patient records that could be easily accessed on a cell phone by a health care professional or the patients themselves on demand. Data on protein biomarkers have a large potential to be measured in point-of-care devices, particularly diagnostic panels that could provide a continually updated, personalized record of a disease like cancer. Electrochemical immunoassays have been popular among protein detection methods due to their inherent high sensitivity and ease of coupling with screen-printed and inkjet-printed electrodes. Integrated chips featuring these kinds of electrodes can be built at low cost and designed for ease of automation. Enzyme-linked immunosorbent assay (ELISA) features are adopted in most of these ultrasensitive detection systems, with microfluidics allowing easy manipulation and good fluid dynamics to deliver reagents and detect the desired proteins. Several of these ultrasensitive systems have detected biomarker panels ranging from four to eight proteins, which in many cases when a specific cancer is suspected may be sufficient. However, a grand challenge lies in engineering microfluidic-printed electrode devices for the simultaneous detection of larger protein panels (e.g., 50-100) that could be used to test for many types of cancers, as well as other diseases for truly personalized care.
Collapse
|
4
|
Nanoparticles as Emerging Labels in Electrochemical Immunosensors. SENSORS 2019; 19:s19235137. [PMID: 31771201 PMCID: PMC6928605 DOI: 10.3390/s19235137] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/28/2019] [Revised: 11/19/2019] [Accepted: 11/21/2019] [Indexed: 12/21/2022]
Abstract
This review shows recent trends in the use of nanoparticles as labels for electrochemical immunosensing applications. Some general considerations on the principles of both the direct detection based on redox properties and indirect detection through electrocatalytic properties, before focusing on the applications for mainly proteins detection, are given. Emerging use as blocking tags in nanochannels-based immunosensing systems is also covered in this review. Finally, aspects related to the analytical performance of the developed devices together with prospects for future improvements and applications are discussed.
Collapse
|
5
|
Martín-Yerga D. Electrochemical Detection and Characterization of Nanoparticles with Printed Devices. BIOSENSORS 2019; 9:E47. [PMID: 30925772 PMCID: PMC6627282 DOI: 10.3390/bios9020047] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/24/2019] [Revised: 03/16/2019] [Accepted: 03/25/2019] [Indexed: 12/15/2022]
Abstract
Innovative methods to achieve the user-friendly, quick, and highly sensitive detection of nanomaterials are urgently needed. Nanomaterials have increased importance in commercial products, and there are concerns about the potential risk that they entail for the environment. In addition, detection of nanomaterials can be a highly valuable tool in many applications, such as biosensing. Electrochemical methods using disposable, low-cost, printed electrodes provide excellent analytical performance for the detection of a wide set of nanomaterials. In this review, the foundations and latest advances of several electrochemical strategies for the detection of nanoparticles using cost-effective printed devices are introduced. These strategies will equip the experimentalist with an extensive toolbox for the detection of nanoparticles of different chemical nature and possible applications ranging from quality control to environmental analysis and biosensing.
Collapse
Affiliation(s)
- Daniel Martín-Yerga
- Department of Chemical Engineering, KTH Royal Institute of Technology, 100-44 Stockholm, Sweden.
| |
Collapse
|
6
|
Electrochemical detection of quantum dots by stabilization of electrogenerated copper species. Electrochem commun 2017. [DOI: 10.1016/j.elecom.2016.11.017] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
|
7
|
Martín-Yerga D, Fanjul-Bolado P, Hernández-Santos D, Costa-García A. Enhanced detection of quantum dots by the magnetohydrodynamic effect for electrochemical biosensing. Analyst 2017; 142:1591-1600. [DOI: 10.1039/c7an00086c] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Magnetoelectrochemistry support for screen-printed electrodes.
Collapse
Affiliation(s)
- Daniel Martín-Yerga
- Departamento de Química Física y Analítica
- Universidad de Oviedo
- 33006 Oviedo
- Spain
| | | | | | - Agustín Costa-García
- Departamento de Química Física y Analítica
- Universidad de Oviedo
- 33006 Oviedo
- Spain
| |
Collapse
|
8
|
Grinyte R, Barroso J, Möller M, Saa L, Pavlov V. Microbead QD-ELISA: Microbead ELISA Using Biocatalytic Formation of Quantum Dots for Ultra High Sensitive Optical and Electrochemical Detection. ACS APPLIED MATERIALS & INTERFACES 2016; 8:29252-29260. [PMID: 27753498 DOI: 10.1021/acsami.6b08362] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Electrochemical detection strategies employing semiconductor quantum dots (QDs) open up new opportunities for highly sensitive detection of biological targets. We designed a new assay based on microbead linked enzymatic generation of CdS QDs (Microbead QD-ELISA) and employed it in optical and electrochemical affinity assays for the cancer biomarker superoxide dismutase 2 (SOD2). Biotinylated antibodies against SOD2 were immobilized on the surface of polyvinyl chloride microbeads bearing streptavidin. In order to prevent any non-specific adsorption the microbeads were further blocked with bovine serum albumin. The analyte, SOD2 was captured on microbeads and labeled with alkaline phosphatase-conjugated antibody linked with mouse antibody against SOD2. Hydrolysis of para-nitrophenylphosphate by immobilized alkaline phosphatase triggered the rapid formation of phosphate-stabilized CdS QDs on the surface of microbeads. The resulting semiconductor nanoparticles were detected by fluorescence spectroscopy, microscopy, and square-wave voltammetry (SWV). The electrochemical assay based on the detection with square-wave voltammograms of Cd2+ ions originating from immobilized CdS QDs showed linearity up to 45 ng mL-1, and the limit of SOD2 detection equal to 0.44 ng mL-1 (1.96 × 10-11 M). This detection limit is lower by 2 orders of magnitude in comparison with that of other previously published assays for superoxide dismutase. The electrochemical assay was validated with HepG2 (Human hepatocellular carcinoma) cell lysate containing SOD2.
Collapse
Affiliation(s)
- Ruta Grinyte
- CIC biomaGUNE , Paseo de Miramón 182, Donostia-San Sebastián 20009, Spain
| | - Javier Barroso
- CIC biomaGUNE , Paseo de Miramón 182, Donostia-San Sebastián 20009, Spain
| | - Marco Möller
- CIC biomaGUNE , Paseo de Miramón 182, Donostia-San Sebastián 20009, Spain
| | - Laura Saa
- CIC biomaGUNE , Paseo de Miramón 182, Donostia-San Sebastián 20009, Spain
| | - Valeri Pavlov
- CIC biomaGUNE , Paseo de Miramón 182, Donostia-San Sebastián 20009, Spain
| |
Collapse
|
9
|
Valera E, Hernández-Albors A, Marco MP. Electrochemical coding strategies using metallic nanoprobes for biosensing applications. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2015.12.014] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
10
|
Martín-Yerga D, Rama EC, Costa-García A. Electrochemical Study and Applications of Selective Electrodeposition of Silver on Quantum Dots. Anal Chem 2016; 88:3739-46. [DOI: 10.1021/acs.analchem.5b04568] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- Daniel Martín-Yerga
- Department
of Physical and
Analytical Chemistry, University of Oviedo, 33006, Oviedo, Spain
| | - Estefanía Costa Rama
- Department
of Physical and
Analytical Chemistry, University of Oviedo, 33006, Oviedo, Spain
| | - Agustín Costa-García
- Department
of Physical and
Analytical Chemistry, University of Oviedo, 33006, Oviedo, Spain
| |
Collapse
|
11
|
Medina-Sánchez M, Miserere S, Cadevall M, Merkoçi A. Enhanced detection of quantum dots labeled protein by simultaneous bismuth electrodeposition into microfluidic channel. Electrophoresis 2015; 37:432-7. [PMID: 26419211 DOI: 10.1002/elps.201500288] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2015] [Revised: 07/22/2015] [Accepted: 07/24/2015] [Indexed: 11/07/2022]
Abstract
In this study, we propose an electrochemical immunoassay into a disposable microfluidic platform, using quantum dots (QDs) as labels and their enhanced detection using bismuth as an alternative to mercury electrodes. CdSe@ZnS QDs were used to tag human IgG as a model protein and detected through highly sensitive stripping voltammetry of the dissolved metallic component (cadmium in our case). The modification of the screen printed carbon electrodes (SPCEs) was done by a simple electrodeposition of bismuth that was previously mixed with the sample containing QDs. A magneto-immunosandwich assay was performed using a micromixer. A magnet placed at its outlet in order to capture the magnetic beads used as solid support for the immunoassay. SPCEs were integrated at the end of the channel as detector. Different parameters such as bismuth concentration, flow rate, and incubation times, were optimized. The LOD for HIgG in presence of bismuth was 3.5 ng/mL with a RSD of 13.2%. This LOD was about 3.3-fold lower than the one obtained without bismuth. Furthermore, the sensitivity of the system was increased 100-fold respect to experiments carried out with classical screen-printed electrodes, both in presence of bismuth.
Collapse
Affiliation(s)
- Mariana Medina-Sánchez
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and The Barcelona Institute of Science and Technology, Campus UAB, Bellaterra, Barcelona, Spain
| | - Sandrine Miserere
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and The Barcelona Institute of Science and Technology, Campus UAB, Bellaterra, Barcelona, Spain
| | - Miquell Cadevall
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and The Barcelona Institute of Science and Technology, Campus UAB, Bellaterra, Barcelona, Spain
| | - Arben Merkoçi
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and The Barcelona Institute of Science and Technology, Campus UAB, Bellaterra, Barcelona, Spain.,Institució Catalana de Recerca i Estudis Avançats (ICREA), Barcelona, Spain
| |
Collapse
|
12
|
Martín-Yerga D, Bouzas-Ramos D, Menéndez-Miranda M, Bustos ARM, Encinar JR, Costa-Fernández JM, Sanz-Medel A, Costa-García A. Voltammetric determination of size and particle concentration of Cd-based quantum dots. Electrochim Acta 2015. [DOI: 10.1016/j.electacta.2015.03.051] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
13
|
Cloake SJ, Toh HS, Lee PT, Salter C, Johnston C, Compton RG. Anodic stripping voltammetry of silver nanoparticles: aggregation leads to incomplete stripping. ChemistryOpen 2015; 4:22-6. [PMID: 25861566 PMCID: PMC4380949 DOI: 10.1002/open.201402050] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2014] [Indexed: 11/18/2022] Open
Abstract
The influence of nanoparticle aggregation on anodic stripping voltammetry is reported. Dopamine-capped silver nanoparticles were chosen as a model system, and melamine was used to induce aggregation in the nanoparticles. Through the anodic stripping of the silver nanoparticles that were aggregated to different extents, it was found that the peak area of the oxidative signal corresponding to the stripping of silver to silver(I) ions decreases with increasing aggregation. Aggregation causes incomplete stripping of the silver nanoparticles. Two possible mechanisms of 'partial oxidation' and 'inactivation' of the nanoparticles are proposed to account for this finding. Aggregation effects must be considered when anodic stripping voltammetry is used for nanoparticle detection and quantification. Hence, drop casting, which is known to lead to aggregation, is not encouraged for preparing electrodes for analytical purposes.
Collapse
Affiliation(s)
- Samantha J Cloake
- Physical & Theoretical Chemistry Laboratory, Oxford UniversitySouth Parks Road, Oxford OX1 3QZ (UK)
| | - Her Shuang Toh
- Physical & Theoretical Chemistry Laboratory, Oxford UniversitySouth Parks Road, Oxford OX1 3QZ (UK)
| | - Patricia T Lee
- Physical & Theoretical Chemistry Laboratory, Oxford UniversitySouth Parks Road, Oxford OX1 3QZ (UK)
| | - Chris Salter
- Department of Materials, Oxford UniversityParks Road, Oxford OX1 3PH (UK)
| | - Colin Johnston
- Department of Materials, Oxford UniversityParks Road, Oxford OX1 3PH (UK)
| | - Richard G Compton
- Physical & Theoretical Chemistry Laboratory, Oxford UniversitySouth Parks Road, Oxford OX1 3QZ (UK)
| |
Collapse
|
14
|
Determination of Silver-Modified Titanium Phosphate Nanoparticles by Voltammetric and Electrocatalytic Methods. ELECTROANAL 2014. [DOI: 10.1002/elan.201400519] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
15
|
Medina-Sánchez M, Miserere S, Morales-Narváez E, Merkoçi A. On-chip magneto-immunoassay for Alzheimer's biomarker electrochemical detection by using quantum dots as labels. Biosens Bioelectron 2014; 54:279-84. [DOI: 10.1016/j.bios.2013.10.069] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2013] [Revised: 10/21/2013] [Accepted: 10/23/2013] [Indexed: 12/13/2022]
|
16
|
A one-step, electrochemical biosensing strategy that is based on transport of signaling CdS nanoparticles controlled bybiomolecules. Biosens Bioelectron 2013; 42:603-7. [DOI: 10.1016/j.bios.2012.11.018] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2012] [Revised: 10/22/2012] [Accepted: 11/12/2012] [Indexed: 11/23/2022]
|
17
|
Giovanni M, Pumera M. Molybdenum metallic nanoparticle detection via differential pulse voltammetry. Electrochem commun 2011. [DOI: 10.1016/j.elecom.2010.12.014] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
18
|
Marín S, Pujals S, Giralt E, Merkoçi A. Electrochemical Investigation of Cellular Uptake of Quantum Dots Decorated with a Proline-Rich Cell Penetrating Peptide. Bioconjug Chem 2011; 22:180-5. [DOI: 10.1021/bc100207w] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Sergio Marín
- Nanobioelectronics & Biosensors Group, CIN2 (ICN-CSIC) Institut Català de Nanotecnologia, Barcelona, Spain
- Department of Chemistry, Universitat Autònoma de Barcelona, Bellaterra, Barcelona, Spain
| | - Sílvia Pujals
- Institute for Research in Biomedicine, Barcelona Scientific Park, Barcelona, Spain
| | - Ernest Giralt
- Institute for Research in Biomedicine, Barcelona Scientific Park, Barcelona, Spain
- Department of Organic Chemistry, University of Barcelona, Barcelona, Spain
| | - Arben Merkoçi
- Nanobioelectronics & Biosensors Group, CIN2 (ICN-CSIC) Institut Català de Nanotecnologia, Barcelona, Spain
- Department of Chemistry, Universitat Autònoma de Barcelona, Bellaterra, Barcelona, Spain
- ICREA, Barcelona, Spain
| |
Collapse
|
19
|
Rengaraj S, Ferancova A, Jee S, Venkataraj S, Kim Y, Labuda J, Sillanpää M. Physical and electrochemical characterization of CdS hollow microspheres prepared by a novel template free solution phase method. Electrochim Acta 2010. [DOI: 10.1016/j.electacta.2010.09.019] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
20
|
de la Escosura-Muñiz A, Merkoçi A. Electrochemical detection of proteins using nanoparticles: applications to diagnostics. ACTA ACUST UNITED AC 2009; 4:21-37. [DOI: 10.1517/17530050903386661] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
21
|
de la Escosura-Muñiz A, Sánchez-Espinel C, Díaz-Freitas B, González-Fernández Á, Maltez-da Costa M, Merkoçi A. Rapid Identification and Quantification of Tumor Cells Using an Electrocatalytic Method Based on Gold Nanoparticles. Anal Chem 2009; 81:10268-74. [DOI: 10.1021/ac902087k] [Citation(s) in RCA: 86] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Alfredo de la Escosura-Muñiz
- Nanobioelectronics & Biosensors Group, Catalan Institute of Nanotechnology, CIN2 (ICN-CSIC), Barcelona, Spain, Aragon Institute of Nanoscience, University of Zaragoza, Zaragoza, Spain, Immunology Group and Unidad Compartida del Complejo Hospitalario Universitario de Vigo, Edificio de Ciencias Experimentales, Universidade de Vigo, Vigo, Spain, and ICREA, Barcelona, Spain
| | - Christian Sánchez-Espinel
- Nanobioelectronics & Biosensors Group, Catalan Institute of Nanotechnology, CIN2 (ICN-CSIC), Barcelona, Spain, Aragon Institute of Nanoscience, University of Zaragoza, Zaragoza, Spain, Immunology Group and Unidad Compartida del Complejo Hospitalario Universitario de Vigo, Edificio de Ciencias Experimentales, Universidade de Vigo, Vigo, Spain, and ICREA, Barcelona, Spain
| | - Belén Díaz-Freitas
- Nanobioelectronics & Biosensors Group, Catalan Institute of Nanotechnology, CIN2 (ICN-CSIC), Barcelona, Spain, Aragon Institute of Nanoscience, University of Zaragoza, Zaragoza, Spain, Immunology Group and Unidad Compartida del Complejo Hospitalario Universitario de Vigo, Edificio de Ciencias Experimentales, Universidade de Vigo, Vigo, Spain, and ICREA, Barcelona, Spain
| | - África González-Fernández
- Nanobioelectronics & Biosensors Group, Catalan Institute of Nanotechnology, CIN2 (ICN-CSIC), Barcelona, Spain, Aragon Institute of Nanoscience, University of Zaragoza, Zaragoza, Spain, Immunology Group and Unidad Compartida del Complejo Hospitalario Universitario de Vigo, Edificio de Ciencias Experimentales, Universidade de Vigo, Vigo, Spain, and ICREA, Barcelona, Spain
| | - Marisa Maltez-da Costa
- Nanobioelectronics & Biosensors Group, Catalan Institute of Nanotechnology, CIN2 (ICN-CSIC), Barcelona, Spain, Aragon Institute of Nanoscience, University of Zaragoza, Zaragoza, Spain, Immunology Group and Unidad Compartida del Complejo Hospitalario Universitario de Vigo, Edificio de Ciencias Experimentales, Universidade de Vigo, Vigo, Spain, and ICREA, Barcelona, Spain
| | - Arben Merkoçi
- Nanobioelectronics & Biosensors Group, Catalan Institute of Nanotechnology, CIN2 (ICN-CSIC), Barcelona, Spain, Aragon Institute of Nanoscience, University of Zaragoza, Zaragoza, Spain, Immunology Group and Unidad Compartida del Complejo Hospitalario Universitario de Vigo, Edificio de Ciencias Experimentales, Universidade de Vigo, Vigo, Spain, and ICREA, Barcelona, Spain
| |
Collapse
|
22
|
Malý J, Lampová H, Semerádtová A, Stofik M, Kovácik L. The synthesis and characterization of biotin-silver-dendrimer nanocomposites as novel bioselective labels. NANOTECHNOLOGY 2009; 20:385101. [PMID: 19713578 DOI: 10.1088/0957-4484/20/38/385101] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
This paper presents a synthesis of a novel nanoparticle label with selective biorecognition properties based on a biotinylated silver-dendrimer nanocomposite (AgDNC). Two types of labels, a biotin-AgDNC (bio-AgDNC) and a biotinylated AgDNC with a poly(ethylene)glycol spacer (bio-PEG-AgDNC), were synthesized from a generation 7 (G7) hydroxyl-terminated ethylenediamine-core-type (2-carbon core) PAMAM dendrimer (DDM) by an N,N'-dicyclohexylcarbodiimide (DDC) biotin coupling and a NaBH(4) silver reduction method. Synthesized conjugates were characterized by several analytical methods, such as UV-vis, FTIR, AFM, TEM, ELISA, HABA assay and SPR. The results show that stable biotinylated nanocomposites can be formed either with internalized silver nanoparticles (AgNPs) in a DMM polymer backbone ('type I') or as externally protected ('type E'), depending on the molar ratio of the silver/DMM conjugate and type of conjugate. Furthermore, the selective biorecognition function of the biotin is not affected by the AgNPs' synthesis step, which allows a potential application of silver nanocomposite conjugates as biospecific labels in various bioanalytical assays, or potentially as fluorescence cell biomarkers. An exploitation of the presented label in the development of electrochemical immunosensors is anticipated.
Collapse
Affiliation(s)
- J Malý
- Faculty of Science, University of J E Purkynje, 40096 Usti nad Labem, Czech Republic.
| | | | | | | | | |
Collapse
|
23
|
Štofik M, Strýhal Z, Malý J. Dendrimer-encapsulated silver nanoparticles as a novel electrochemical label for sensitive immunosensors. Biosens Bioelectron 2009; 24:1918-23. [DOI: 10.1016/j.bios.2008.09.028] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2008] [Revised: 09/08/2008] [Accepted: 09/24/2008] [Indexed: 12/21/2022]
|
24
|
Marin S, Merkoçi A. Direct electrochemical stripping detection of cystic-fibrosis-related DNA linked through cadmium sulfide quantum dots. NANOTECHNOLOGY 2009; 20:055101. [PMID: 19417332 DOI: 10.1088/0957-4484/20/5/055101] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Electrochemical detection of a cadmium sulfide quantum dots (CdS QDs)-DNA complex connected to paramagnetic microbeads (MB) was performed without the need for chemical dissolving. The method is based on dropping 20 microl of CdS QD-DNA-MB suspension on the surface of a screen-printed electrode. It is followed by magnetic collection on the surface of the working electrode and electrochemical detection using square-wave voltammetry (SWV), giving a well-shaped and sensitive analytical signal. A cystic-fibrosis-related DNA sequence was sandwiched between the two DNA probes. One DNA probe is linked via biotin-streptavidin bonding with MB and the other one via thiol groups with the CdS QD used as tags. Nonspecific signals of DNA were minimized using a blocking agent and the results obtained were successfully employed in a model DNA sensor with an interest in future applications in the clinical field. The developed nanoparticle biosensing system may offer numerous opportunities in other fields where fast, low cost and efficient detection of small volume samples is required.
Collapse
Affiliation(s)
- Sergio Marin
- Institut Català de Nanotecnologia, Universitat Autònoma de Barcelona, Barcelona, Catalonia, Spain
| | | |
Collapse
|
25
|
|