1
|
Cabezudo Ballesteros S, Sanabria Carretero P, Reinoso Barbero F. Review of electrical impedance tomography in the pediatric patient. REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION 2024; 71:479-485. [PMID: 38458492 DOI: 10.1016/j.redare.2024.03.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Accepted: 08/28/2023] [Indexed: 03/10/2024]
Abstract
Electrical impedance tomography (EIT) is a new method of monitoring non-invasive mechanical ventilation, at the bedside and useful in critically ill patients. It allows lung monitoring of ventilation and perfusion, obtaining images that provide information on lung function. It is based on the physical principle of impedanciometry or the body's ability to conduct an electrical current. Various studies have shown its usefulness both in adults and in pediatrics in respiratory distress syndrome, pneumonia and atelectasis in addition to pulmonary thromboembolism and pulmonary hypertension by also providing information on pulmonary perfusion, and may be very useful in perioperative medicine; especially in pediatrics avoiding repetitive imaging tests with ionizing radiation.
Collapse
Affiliation(s)
| | - P Sanabria Carretero
- Servicio de Anestesia y Reanimación, Hospital Universitario La Paz, Madrid, Spain
| | - F Reinoso Barbero
- Servicio de Anestesia y Reanimación, Hospital Universitario La Paz, Madrid, Spain
| |
Collapse
|
2
|
Zheng Z, Wu Z, Zhao R, Ni Y, Jing X, Gao S. A Review of EMG-, FMG-, and EIT-Based Biosensors and Relevant Human–Machine Interactivities and Biomedical Applications. BIOSENSORS 2022; 12:bios12070516. [PMID: 35884319 PMCID: PMC9313012 DOI: 10.3390/bios12070516] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 07/06/2022] [Accepted: 07/09/2022] [Indexed: 11/23/2022]
Abstract
Wearables developed for human body signal detection receive increasing attention in the current decade. Compared to implantable sensors, wearables are more focused on body motion detection, which can support human–machine interaction (HMI) and biomedical applications. In wearables, electromyography (EMG)-, force myography (FMG)-, and electrical impedance tomography (EIT)-based body information monitoring technologies are broadly presented. In the literature, all of them have been adopted for many similar application scenarios, which easily confuses researchers when they start to explore the area. Hence, in this article, we review the three technologies in detail, from basics including working principles, device architectures, interpretation algorithms, application examples, merits and drawbacks, to state-of-the-art works, challenges remaining to be solved and the outlook of the field. We believe the content in this paper could help readers create a whole image of designing and applying the three technologies in relevant scenarios.
Collapse
Affiliation(s)
| | | | | | | | | | - Shuo Gao
- Correspondence: ; Tel.: +86-18600737330
| |
Collapse
|
3
|
Borgmann S, Linz K, Braun C, Dzierzawski P, Spassov S, Wenzel C, Schumann S. Lung area estimation using functional tidal electrical impedance variation images and active contouring. Physiol Meas 2022; 43. [PMID: 35764094 DOI: 10.1088/1361-6579/ac7cc3] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Accepted: 06/28/2022] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Electrical impedance tomography is a valuable tool for monitoring global and regional lung mechanics. To evaluate the recorded data, an accurate estimate of the lung area is crucial. APPROACH We present two novel methods for estimating the lung area using functional tidal images or active contouring methods. A convolutional neural network was trained to determine, whether or not the heart region was visible within tidal images. In addition, the effects of lung area mirroring were investigated. The performance of the methods and the effects of mirroring were evaluated via a score based on the impedance magnitudes in functional tidal images. MAIN RESULTS Our analyses showed that the method based on functional tidal images provided the best estimate of the lung area. Mirroring of the lung area had an impact on the accuracy of area estimation for both methods. The achieved accuracy of the neural network's classification was 94%. For images without a visible heart area, the subtraction of a heart template proved to be a pragmatic approach with good results. SIGNIFICANCE In summary, we developed a routine for estimation of the lung area combined with estimation of the heart area in electrical impedance tomography images.
Collapse
Affiliation(s)
- Silke Borgmann
- Universitatsklinikum Freiburg, Hugstetter Straße 55, Freiburg, 79106, GERMANY
| | - Kim Linz
- Universitatsklinikum Freiburg, Hugstetter Straße 55, Freiburg, 79106, GERMANY
| | - Christian Braun
- Universitatsklinikum Freiburg, Hugstetter Straße 55, Freiburg, 79106, GERMANY
| | - Patryk Dzierzawski
- Universitatsklinikum Freiburg, Hugstetter Straße 55, Freiburg, 79106, GERMANY
| | - Sashko Spassov
- Universitatsklinikum Freiburg, Hugstetter Straße 55, Freiburg, 79106, GERMANY
| | - Christin Wenzel
- Anesthesiology and Critical Care, University of Freiburg Faculty of Medicine, Hugstetter Straße 55, Freiburg, 79106, GERMANY
| | - Stefan Schumann
- Universitatsklinikum Freiburg, Hugstetter Straße 55, Freiburg, 79106, GERMANY
| |
Collapse
|
4
|
Lung Ultrasound and Electrical Impedance Tomography During Ventilator-Induced Lung Injury. Crit Care Med 2022; 50:e630-e637. [PMID: 35132021 DOI: 10.1097/ccm.0000000000005479] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES Lung damage during mechanical ventilation involves lung volume and alveolar water content, and lung ultrasound (LUS) and electrical impedance tomography changes are related to these variables. We investigated whether these techniques may detect any signal modification during the development of ventilator-induced lung injury (VILI). DESIGN Experimental animal study. SETTING Experimental Department of a University Hospital. SUBJECTS Forty-two female pigs (24.2 ± 2.0 kg). INTERVENTIONS The animals were randomized into three groups (n = 14): high tidal volume (TV) (mean TV, 803.0 ± 121.7 mL), high respiratory rate (RR) (mean RR, 40.3 ± 1.1 beats/min), and high positive-end-expiratory pressure (PEEP) (mean PEEP, 24.0 ± 1.1 cm H2O). The study lasted 48 hours. At baseline and at 30 minutes, and subsequently every 6 hours, we recorded extravascular lung water, end-expiratory lung volume, lung strain, respiratory mechanics, hemodynamics, and gas exchange. At the same time-point, end-expiratory impedance was recorded relatively to the baseline. LUS was assessed every 12 hours in 12 fields, each scoring from 0 (presence of A-lines) to 3 (consolidation). MEASUREMENTS AND MAIN RESULTS In a multiple regression model, the ratio between extravascular lung water and end-expiratory lung volume was significantly associated with the LUS total score (p < 0.002; adjusted R2, 0.21). The variables independently associated with the end-expiratory difference in lung impedance were lung strain (p < 0.001; adjusted R2, 0.18) and extravascular lung water (p < 0.001; adjusted R2, 0.11). CONCLUSIONS Data suggest as follows. First, what determines the LUS score is the ratio between water and gas and not water alone. Therefore, caution is needed when an improvement of LUS score follows a variation of the lung gas content, as after a PEEP increase. Second, what determines the end-expiratory difference in lung impedance is the strain level that may disrupt the intercellular junction, therefore altering lung impedance. In addition, the increase in extravascular lung water during VILI development contributed to the observed decrease in impedance.
Collapse
|
5
|
Hu CL, Cheng IC, Huang CH, Liao YT, Lin WC, Tsai KJ, Chi CH, Chen CW, Wu CH, Lin IT, Li CJ, Lin CW. Dry Wearable Textile Electrodes for Portable Electrical Impedance Tomography. SENSORS 2021; 21:s21206789. [PMID: 34696002 PMCID: PMC8537054 DOI: 10.3390/s21206789] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 10/08/2021] [Accepted: 10/09/2021] [Indexed: 11/16/2022]
Abstract
Electrical impedance tomography (EIT), a noninvasive and radiation-free medical imaging technique, has been used for continuous real-time regional lung aeration. However, adhesive electrodes could cause discomfort and increase the risk of skin injury during prolonged measurement. Additionally, the conductive gel between the electrodes and skin could evaporate in long-term usage and deteriorate the signal quality. To address these issues, in this work, textile electrodes integrated with a clothing belt are proposed to achieve EIT lung imaging along with a custom portable EIT system. The simulation and experimental results have verified the validity of the proposed portable EIT system. Furthermore, the imaging results of using the proposed textile electrodes were compared with commercial electrocardiogram electrodes to evaluate their performance.
Collapse
Affiliation(s)
- Chang-Lin Hu
- Industrial Technology Research Institute, Hsinchu 310, Taiwan; (I.-C.C.); (K.-J.T.); (C.-J.L.); (C.-W.L.)
- Correspondence:
| | - I-Cheng Cheng
- Industrial Technology Research Institute, Hsinchu 310, Taiwan; (I.-C.C.); (K.-J.T.); (C.-J.L.); (C.-W.L.)
| | - Chih-Hsien Huang
- Department of Electrical Engineering, National Cheng Kung University, Tainan 701, Taiwan; (C.-H.H.); (C.-H.W.)
| | - Yu-Te Liao
- Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu 300, Taiwan; (Y.-T.L.); (I.-T.L.)
| | - Wei-Chieh Lin
- Division of Critical Care Medicine, Department of Internal Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan 701, Taiwan; (W.-C.L.); (C.-W.C.)
| | - Kun-Ju Tsai
- Industrial Technology Research Institute, Hsinchu 310, Taiwan; (I.-C.C.); (K.-J.T.); (C.-J.L.); (C.-W.L.)
| | - Chih-Hsien Chi
- Department of Emergency Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan 701, Taiwan;
| | - Chang-Wen Chen
- Division of Critical Care Medicine, Department of Internal Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan 701, Taiwan; (W.-C.L.); (C.-W.C.)
| | - Chia-Hsi Wu
- Department of Electrical Engineering, National Cheng Kung University, Tainan 701, Taiwan; (C.-H.H.); (C.-H.W.)
| | - I-Te Lin
- Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu 300, Taiwan; (Y.-T.L.); (I.-T.L.)
| | - Chien-Ju Li
- Industrial Technology Research Institute, Hsinchu 310, Taiwan; (I.-C.C.); (K.-J.T.); (C.-J.L.); (C.-W.L.)
| | - Chii-Wann Lin
- Industrial Technology Research Institute, Hsinchu 310, Taiwan; (I.-C.C.); (K.-J.T.); (C.-J.L.); (C.-W.L.)
- Department of Biomedical Engineering, National Taiwan University, Taipei 106, Taiwan
| |
Collapse
|
6
|
Kobayashi M, Wada Y, Okumiya Y, Yataka K, Suzuki K, Nakashima Y, Ishibashi H, Okubo K. Use of carbon nanotube sensor for detecting postoperative abnormal respiratory waveforms. J Thorac Dis 2021; 13:3051-3060. [PMID: 34164196 PMCID: PMC8182515 DOI: 10.21037/jtd-21-156] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Background This feasibility study aimed to detect respiratory waveforms from thoracic movements and evaluate if postoperative complications could be predicted using a carbon nanotube sensor. Methods Fifty patients who underwent lung resection for lung tumors were enrolled. The lung monitoring system of the carbon nanotube sensor was placed on bilateral chest walls across the 6th–9th ribs to measure chest wall motion. We examined the respiratory waveform in relation to surgical findings, postoperative course, and complications using Hilbert transform and Fast Fourier Transform (FFT). Results Of 50 patients (37 males, 13 females), 22 were included in the normal lung function group and 28 were included in the low lung function group. The respiratory rate and waveform indicated a regular pattern in the normal lung function group and the respiratory rate could be detected. Conversely, irregular respiratory pattern was detected in 70% of patients in the low lung function group. There was no significant different overall envelope peak value between operated side and non-operated side (0.195±0.05 and 0.18±0.06). In contrast, there was significantly high peak value in the presence of postoperative complications (P<0.05). And there was a significantly higher peak value in air leakage presence than air leakage absence in operated side (P=0.045). Conclusions The present study confirmed the feasibility of the sensor. It is promising in visualizing the respiratory state and detecting respiratory changes postoperatively.
Collapse
Affiliation(s)
- Masashi Kobayashi
- Department of Thoracic Surgery, Tokyo Medical and Dental University, Tokyo, Japan
| | - Yohei Wada
- Research and Development Division, Technology Unit, Yamaha Corporation, Hamamatsu, Japan
| | - Yasuro Okumiya
- Research and Development Division, Technology Unit, Yamaha Corporation, Hamamatsu, Japan
| | - Koji Yataka
- Research and Development Division, Technology Unit, Yamaha Corporation, Hamamatsu, Japan
| | - Katsunori Suzuki
- Research and Development Division, Technology Unit, Yamaha Corporation, Hamamatsu, Japan
| | - Yasuhiro Nakashima
- Department of Thoracic Surgery, Tokyo Medical and Dental University, Tokyo, Japan
| | - Hironori Ishibashi
- Department of Thoracic Surgery, Tokyo Medical and Dental University, Tokyo, Japan
| | - Kenichi Okubo
- Department of Thoracic Surgery, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
7
|
|
8
|
Mohino-Herranz I, Gil-Pita R, Rosa-Zurera M, Seoane F. Activity Recognition Using Wearable Physiological Measurements: Selection of Features from a Comprehensive Literature Study. SENSORS (BASEL, SWITZERLAND) 2019; 19:E5524. [PMID: 31847261 PMCID: PMC6960825 DOI: 10.3390/s19245524] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Revised: 12/07/2019] [Accepted: 12/11/2019] [Indexed: 11/17/2022]
Abstract
Activity and emotion recognition based on physiological signal processing in health care applications is a relevant research field, with promising future and relevant applications, such as health at work or preventive care. This paper carries out a deep analysis of features proposed to extract information from the electrocardiogram, thoracic electrical bioimpedance, and electrodermal activity signals. The activities analyzed are: neutral, emotional, mental and physical. A total number of 533 features are tested for activity recognition, performing a comprehensive study taking into consideration the prediction accuracy, feature calculation, window length, and type of classifier. Feature selection to know the most relevant features from the complete set is implemented using a genetic algorithm, with a different number of features. This study has allowed us to determine the best number of features to obtain a good error probability avoiding over-fitting, and the best subset of features among those proposed in the literature. The lowest error probability that is obtained is 22.2%, with 40 features, a least squares error classifier, and 40 seconds window length.
Collapse
Affiliation(s)
- Inma Mohino-Herranz
- Department of Signal Theory and Communications, University of Alcala, 28805 Alcala de Henares, Madrid, Spain; (R.G.-P.); (M.R.-Z.)
| | - Roberto Gil-Pita
- Department of Signal Theory and Communications, University of Alcala, 28805 Alcala de Henares, Madrid, Spain; (R.G.-P.); (M.R.-Z.)
| | - Manuel Rosa-Zurera
- Department of Signal Theory and Communications, University of Alcala, 28805 Alcala de Henares, Madrid, Spain; (R.G.-P.); (M.R.-Z.)
| | - Fernando Seoane
- Clinical Science, Intervention an Technology, Karolinska Institutet, 17177 Stockholm, Sweden;
- Department Biomedical Engineering, Karolinska University Hospital, 14186 Stockholm, Sweden
- Swedish School of Textiles, University of Boras, 50190 Boras, Sweden
| |
Collapse
|
9
|
Spinelli E, Mauri T, Fogagnolo A, Scaramuzzo G, Rundo A, Grieco DL, Grasselli G, Volta CA, Spadaro S. Electrical impedance tomography in perioperative medicine: careful respiratory monitoring for tailored interventions. BMC Anesthesiol 2019; 19:140. [PMID: 31390977 PMCID: PMC6686519 DOI: 10.1186/s12871-019-0814-7] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Accepted: 07/29/2019] [Indexed: 01/26/2023] Open
Abstract
BACKGROUND Electrical impedance tomography (EIT) is a non-invasive radiation-free monitoring technique that provides images based on tissue electrical conductivity of the chest. Several investigations applied EIT in the context of perioperative medicine, which is not confined to the intraoperative period but begins with the preoperative assessment and extends to postoperative follow-up. MAIN BODY EIT could provide careful respiratory monitoring in the preoperative assessment to improve preparation for surgery, during anaesthesia to guide optimal ventilation strategies and to monitor the hemodynamic status and in the postoperative period for early detection of respiratory complications. Moreover, EIT could further enhance care of patients undergoing perioperative diagnostic procedures. This narrative review summarizes the latest evidence on the application of this technique to the surgical patient, focusing also on possible future perspectives. CONCLUSIONS EIT is a promising technique for the perioperative assessment of surgical patients, providing tailored adaptive respiratory and haemodynamic monitoring. Further studies are needed to address the current technological limitations, confirm the findings and evaluate which patients can benefit more from this technology.
Collapse
Affiliation(s)
- Elena Spinelli
- Dipartimento di Anestesia, Rianimazione ed Emergenza-Urgenza, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Università degli studi di Milano, Milan, Italy
| | - Tommaso Mauri
- Dipartimento di Anestesia, Rianimazione ed Emergenza-Urgenza, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Università degli studi di Milano, Milan, Italy
| | - Alberto Fogagnolo
- Department Morphology, Surgery and Experimental medicine, Anesthesia and Intensive care section, University of Ferrara, Azienda Ospedaliera- Universitaria Sant'Anna, 8, Aldo Moro, Ferrara, Italy
| | - Gaetano Scaramuzzo
- Department Morphology, Surgery and Experimental medicine, Anesthesia and Intensive care section, University of Ferrara, Azienda Ospedaliera- Universitaria Sant'Anna, 8, Aldo Moro, Ferrara, Italy
| | - Annalisa Rundo
- UOC Anestesia e Rianimazione, Polo ospedaliero Belcolle ASL, Viterbo, Italy
| | - Domenico Luca Grieco
- Department of Anesthesiology and Intensive Care Medicine, Catholic University of the Sacred Heart, Fondazione "Policlinico Universitario A. Gemelli", Rome, Italy
| | - Giacomo Grasselli
- Dipartimento di Anestesia, Rianimazione ed Emergenza-Urgenza, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Università degli studi di Milano, Milan, Italy
| | - Carlo Alberto Volta
- Department Morphology, Surgery and Experimental medicine, Anesthesia and Intensive care section, University of Ferrara, Azienda Ospedaliera- Universitaria Sant'Anna, 8, Aldo Moro, Ferrara, Italy
| | - Savino Spadaro
- Department Morphology, Surgery and Experimental medicine, Anesthesia and Intensive care section, University of Ferrara, Azienda Ospedaliera- Universitaria Sant'Anna, 8, Aldo Moro, Ferrara, Italy.
| |
Collapse
|
10
|
Electrical Impedance Tomography for Cardio-Pulmonary Monitoring. J Clin Med 2019; 8:jcm8081176. [PMID: 31394721 PMCID: PMC6722958 DOI: 10.3390/jcm8081176] [Citation(s) in RCA: 64] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 08/05/2019] [Accepted: 08/06/2019] [Indexed: 12/14/2022] Open
Abstract
Electrical impedance tomography (EIT) is a bedside monitoring tool that noninvasively visualizes local ventilation and arguably lung perfusion distribution. This article reviews and discusses both methodological and clinical aspects of thoracic EIT. Initially, investigators addressed the validation of EIT to measure regional ventilation. Current studies focus mainly on its clinical applications to quantify lung collapse, tidal recruitment, and lung overdistension to titrate positive end-expiratory pressure (PEEP) and tidal volume. In addition, EIT may help to detect pneumothorax. Recent studies evaluated EIT as a tool to measure regional lung perfusion. Indicator-free EIT measurements might be sufficient to continuously measure cardiac stroke volume. The use of a contrast agent such as saline might be required to assess regional lung perfusion. As a result, EIT-based monitoring of regional ventilation and lung perfusion may visualize local ventilation and perfusion matching, which can be helpful in the treatment of patients with acute respiratory distress syndrome (ARDS).
Collapse
|
11
|
Sosio S, Bellani G, Villa S, Lupieri E, Mauri T, Foti G. A Calibration Technique for the Estimation of Lung Volumes in Nonintubated Subjects by Electrical Impedance Tomography. Respiration 2019; 98:189-197. [PMID: 31195395 DOI: 10.1159/000499159] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2018] [Accepted: 02/26/2019] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Electrical impedance tomography (EIT) is a bedside monitoring technique of the respiratory system that measures impedance changes within the thorax. The close correlation between variations in impedance (ΔZ) and lung volumes (Vt) is known. Unless Vt is measured by an external reference (e.g., spirometry), its absolute value (in milliliters) cannot be determined; however, measurement of Vt would be useful in nonintubated subjects. OBJECTIVE To validate a simplified and feasible calibration method of EIT, which allows estimation of Vt in nonintubated subjects. MATERIALS AND METHODS We performed a prospective study on 13 healthy volunteers. Subjects breathed 10 times in a nonexpandable "calibration balloon" with a known volume while wearing the EIT belt. The relationship between ΔZ and the balloon volume was calculated (ΔZ/Vt). Subsequently, subjects were connected to a mechanical ventilator by a mouthpiece under different settings. Vt was calculated from EIT measurements (VtEIT) by means of the ΔZ/Vt coefficient and compared with the value obtained from the ventilator (Vtflow). RESULTS There was a close correlation between Vtflow and VtEIT (r2 = 0.89). The fit equation was VtEIT = 0.9 × Vtflow +10.1. The highest correlation was found at positive endexpiratory pressure (PEEP) 0 (mean: VtEIT = 0.93 × Vtflow) versus PEEP 8 (mean: VtEIT = 0.8 × Vtflow), p = 0.01. No differences in the fit equation were found between pressure support ventilation (PSV) 0 and PSV 8, p = 0.50. Further analysis showed no statistically significant differences between sex, height, and BMI. CONCLUSION A simple and fast EIT calibration technique enables reliable, noninvasive monitoring of Vt in nonintubated subjects.
Collapse
Affiliation(s)
- Simone Sosio
- Department of Medicine and Surgery, University of Milano Bicocca, Milan, Italy
| | - Giacomo Bellani
- Department of Medicine and Surgery, University of Milano Bicocca, Milan, Italy, .,Department of Emergency and Intensive Care, San Gerardo Hospital, Monza, Italy,
| | - Silvia Villa
- Department of Medicine and Surgery, University of Milano Bicocca, Milan, Italy
| | - Ermes Lupieri
- Department of Medicine and Surgery, University of Milano Bicocca, Milan, Italy
| | - Tommaso Mauri
- Department of Anesthesia, Critical Care, and Emergency, Fondazione IRCCS Ca'Granda Ospedale Maggiore Policlinico, University of Milan, Milan, Italy
| | - Giuseppe Foti
- Department of Medicine and Surgery, University of Milano Bicocca, Milan, Italy.,Department of Emergency and Intensive Care, San Gerardo Hospital, Monza, Italy
| |
Collapse
|
12
|
Victor M, Melo J, Roldán R, Nakamura M, Tucci M, Costa E, Amato M, Yoneyama T, Tanaka H. Modelling approach to obtain regional respiratory mechanics using electrical impedance tomography and volume-dependent elastance model. Physiol Meas 2019; 40:045001. [PMID: 30921784 DOI: 10.1088/1361-6579/ab144a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE This paper presents a method for breath-by-breath estimation of regional respiratory mechanics without the need for special manoeuvres (such as inspiratory pause or low-flow inflation) using electrical impedance tomography (EIT) associated with pressure/airflow waveforms. APPROACH We developed a method to estimate regional parameters using the regional impedance fraction, by multiplying it by global flow and volume waveforms. A volume-dependent elastance model was used to obtain compliance, resistance, volume-independent (E 1), and volume-dependent (E 2) components. Three swine under invasive mechanical ventilation were used to assess internal consistency and illustrate potential applications of our method. One animal (case 1) was ventilated with a broad range of tidal volumes to compare the consistency between regional and global resistances and compliances. Two other animals (cases 2 and 3) had respiratory compliance decreased, respectively, by overdistension and collapse as quantified by x-ray computed tomography. MAIN RESULTS In case 1, derived global estimates obtained from the independent regional estimates were strongly associated with direct measurements of global mechanics (correlation coefficients of 0.9976 and 0.9981 for compliances and resistances, respectively), suggesting consistency of our modelling. In cases 2 and 3, the development of lung overdistension and collapse over time was captured by regional estimates. CONCLUSIONS Using EIT and pressure/airflow waveforms, regional respiratory parameters can be obtained cycle-by-cycle, refining lung function monitoring. SIGNIFICANCE The method allows real-time monitoring of regional parameters and their trends over time, which might be helpful to differentiate deterioration in lung compliance due to overdistension or collapse.
Collapse
Affiliation(s)
- M Victor
- Electronics Engineering Department, Aeronautics Institute of Technology, São Paulo, Brazil
| | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Sadr N, de Chazal P. A comparison of three ECG-derived respiration methods for sleep apnoea detection. Biomed Phys Eng Express 2019. [DOI: 10.1088/2057-1976/aafc80] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
14
|
Mazzotti DR, Lim DC, Sutherland K, Bittencourt L, Mindel JW, Magalang U, Pack AI, de Chazal P, Penzel T. Opportunities for utilizing polysomnography signals to characterize obstructive sleep apnea subtypes and severity. Physiol Meas 2018; 39:09TR01. [PMID: 30047487 DOI: 10.1088/1361-6579/aad5fe] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
BACKGROUND Obstructive sleep apnea (OSA) is a heterogeneous sleep disorder with many pathophysiological pathways to disease. Currently, the diagnosis and classification of OSA is based on the apnea-hypopnea index, which poorly correlates to underlying pathology and clinical consequences. A large number of in-laboratory sleep studies are performed around the world every year, already collecting an enormous amount of physiological data within an individual. Clinically, we have not yet fully taken advantage of this data, but combined with existing analytical approaches, we have the potential to transform the way OSA is managed within an individual patient. Currently, respiratory signals are used to count apneas and hypopneas, but patterns such as inspiratory flow signals can be used to predict optimal OSA treatment. Electrocardiographic data can reveal arrhythmias, but patterns such as heart rate variability can also be used to detect and classify OSA. Electroencephalography is used to score sleep stages and arousals, but specific patterns such as the odds-ratio product can be used to classify how OSA patients responds differently to arousals. OBJECTIVE In this review, we examine these and many other existing computer-aided polysomnography signal processing algorithms and how they can reflect an individual's manifestation of OSA. SIGNIFICANCE Together with current technological advance, it is only a matter of time before advanced automatic signal processing and analysis is widely applied to precision medicine of OSA in the clinical setting.
Collapse
Affiliation(s)
- Diego R Mazzotti
- Center for Sleep and Circadian Neurobiology, University of Pennsylvania, Philadelphia, United States of America
| | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Bialka S, Copik M, Rybczyk K, Owczarek A, Jedrusik E, Czyzewski D, Filipowski M, Rivas E, Ruetzler K, Szarpak L, Misiolek H. Assessment of changes of regional ventilation distribution in the lung tissue depending on the driving pressure applied during high frequency jet ventilation. BMC Anesthesiol 2018; 18:101. [PMID: 30064377 PMCID: PMC6069840 DOI: 10.1186/s12871-018-0552-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Accepted: 06/27/2018] [Indexed: 12/26/2022] Open
Abstract
Background Electrical impedance tomography (EIT) is a tool to monitor regional ventilation distribution in patient’s lungs under general anesthesia. The objective of this study was to assess the regional ventilation distribution using different driving pressures (DP) during high frequency jet ventilation (HFJV). Methods Prospective, observational, cross-over study. Patients undergoing rigid bronchoscopy were ventilated HFJV with DP 1.5 and 2.5 atm. Hemodynamic and ventilation parameters, as well as ventilation in different regions of the lungs in percentage of total ventilation, assessed by EIT, were recorded. Results Thirty-six patients scheduled for elective rigid bronchoscopy. The final analysis included thirty patients. There was no significant difference in systolic, diastolic and mean arterial blood pressure, heart rate, and peripheral saturation between the two groups. Peak inspiratory pressure, mean inspiratory pressure, tidal volume, and minute volume significantly increased in the second, compared to the first intervention group. Furthermore, there were no statistically significant differences between each time profiles in all ROI regions in EIT. Conclusions In our study intraoperative EIT was an effective method of functional monitoring of the lungs during HFJV for rigid bronchoscopy procedure. Lower driving pressure was as effective in providing sufficient ventilation distribution through the lungs as the higher driving pressure but characterized by lower airway pressure. Trial registration The study was registered on ClinicalTrials.gov under no. NCT02997072.
Collapse
Affiliation(s)
- Szymon Bialka
- Chair and Department of Anesthesiology, Intensive Therapy and Emergency Medicine, Medical University of Silesia, Katowice, Poland
| | - Maja Copik
- Chair and Department of Anesthesiology, Intensive Therapy and Emergency Medicine, Medical University of Silesia, Katowice, Poland
| | - Katarzyna Rybczyk
- Chair and Department of Anesthesiology, Intensive Therapy and Emergency Medicine, Medical University of Silesia, Katowice, Poland
| | - Aleksander Owczarek
- Department of Statistics, School of Pharmacy with the Division of Laboratory Medicine in Sosnowiec, Medical University of Silesia, Katowice, Poland
| | - Ewa Jedrusik
- Department of Statistics, School of Pharmacy with the Division of Laboratory Medicine in Sosnowiec, Medical University of Silesia, Katowice, Poland
| | - Damian Czyzewski
- Chair and Department of Chest Surgery, Medical University of Silesia, Katowice, Poland
| | - Marek Filipowski
- Chair and Department of Chest Surgery, Medical University of Silesia, Katowice, Poland
| | - Eva Rivas
- Department of Outcomes Research, Cleveland Clinic, Cleveland, OH, USA.,Hospital Clinic of Barcelona, IDIBPAS, University of Barcelona, Barcelona, Spain
| | - Kurt Ruetzler
- Department of Outcomes Research, Cleveland Clinic, Cleveland, OH, USA
| | - Lukasz Szarpak
- Lazarski University, 43 Swieradowska Str, 02-662, Warsaw, Poland.
| | - Hanna Misiolek
- Chair and Department of Anesthesiology, Intensive Therapy and Emergency Medicine, Medical University of Silesia, Katowice, Poland
| |
Collapse
|
16
|
Sharma H, Sharma KK. ECG-derived respiration based on iterated Hilbert transform and Hilbert vibration decomposition. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2018; 41:429-443. [PMID: 29667117 DOI: 10.1007/s13246-018-0640-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2017] [Accepted: 04/11/2018] [Indexed: 11/26/2022]
Abstract
Monitoring of the respiration using the electrocardiogram (ECG) is desirable for the simultaneous study of cardiac activities and the respiration in the aspects of comfort, mobility, and cost of the healthcare system. This paper proposes a new approach for deriving the respiration from single-lead ECG based on the iterated Hilbert transform (IHT) and the Hilbert vibration decomposition (HVD). The ECG signal is first decomposed into the multicomponent sinusoidal signals using the IHT technique. Afterward, the lower order amplitude components obtained from the IHT are filtered using the HVD to extract the respiration information. Experiments are performed on the Fantasia and Apnea-ECG datasets. The performance of the proposed ECG-derived respiration (EDR) approach is compared with the existing techniques including the principal component analysis (PCA), R-peak amplitudes (RPA), respiratory sinus arrhythmia (RSA), slopes of the QRS complex, and R-wave angle. The proposed technique showed the higher median values of correlation (first and third quartile) for both the Fantasia and Apnea-ECG datasets as 0.699 (0.55, 0.82) and 0.57 (0.40, 0.73), respectively. Also, the proposed algorithm provided the lowest values of the mean absolute error and the average percentage error computed from the EDR and reference (recorded) respiration signals for both the Fantasia and Apnea-ECG datasets as 1.27 and 9.3%, and 1.35 and 10.2%, respectively. In the experiments performed over different age group subjects of the Fantasia dataset, the proposed algorithm provided effective results in the younger population but outperformed the existing techniques in the case of elderly subjects. The proposed EDR technique has the advantages over existing techniques in terms of the better agreement in the respiratory rates and specifically, it reduces the need for an extra step required for the detection of fiducial points in the ECG for the estimation of respiration which makes the process effective and less-complex. The above performance results obtained from two different datasets validate that the proposed approach can be used for monitoring of the respiration using single-lead ECG.
Collapse
Affiliation(s)
- Hemant Sharma
- Department of Electronics and Communication Engineering, National Institute of Technology Rourkela, Rourkela, India.
| | - K K Sharma
- Department of Electronics and Communication Engineering, Malaviya National Institute of Technology Jaipur, Jaipur, India
| |
Collapse
|
17
|
Zhao Z, Yun PJ, Kuo YL, Fu F, Dai M, Frerichs I, Möller K. Comparison of different functional EIT approaches to quantify tidal ventilation distribution. Physiol Meas 2018; 39:01NT01. [DOI: 10.1088/1361-6579/aa9eb4] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
18
|
|
19
|
Sadr N, de Chazal P. A fast approximation method for principal component analysis applied to ECG derived respiration for OSA detection. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2016:6198-6201. [PMID: 28269667 DOI: 10.1109/embc.2016.7592144] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
In this paper, we present an approximation method for principal component analysis (PCA) and apply it to estimating the respiration from the overnight ECG signal. The approximation method is computationally fast with low memory requirements. We compare it to a full PCA method which is applied to segments of the ECG. Features were calculated from the two ECG derived respiration signals (EDR) and classifiers trained to detect obstructive sleep apnoea (OSA). The Extreme Learning Machine and Linear Discriminant classifier were used to classify the recordings. The data from 35 overnight ECG recordings from MIT PhysioNet Apnea-ECG training database was utilized in the paper. Apnoea detection was evaluated with leave-one-record-out cross validation. The approximated PCA method obtained the highest accuracy of 76.4% by ELM classifier at fan-out 10 and accuracy of 78.4% by LDA. While, the segmented PCA achieved lower accuracies for both classifiers, 75.9% by ELM classifier and 76.6% by LDA. We conclude that the approximation method for PCA is well suited to deriving the respiration signal from overnight ECGs.
Collapse
|
20
|
Durlak W, Klimek M, Kwinta P. Regional lung ventilation pattern in preschool children with bronchopulmonary dysplasia is modified by bronchodilator response. Pediatr Pulmonol 2017; 52:353-359. [PMID: 28221733 DOI: 10.1002/ppul.23540] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2016] [Revised: 07/11/2016] [Accepted: 07/14/2016] [Indexed: 11/07/2022]
Abstract
BACKGROUND Bronchopulmonary dysplasia (BPD) remains a significant long-term complication of prematurity. A standardized method of pulmonary function testing is still not available in preschool children with BPD. We investigated the feasibility of Electrical Impedance Segmentography (EIS) monitoring in this group and the impact of bronchodilator response (BDR) to salbutamol on the pattern of lung ventilation. METHODS We conducted a follow-up study of 4-year-old premature children who had been treated in the tertiary NICU. The cohort was divided into two groups based on the presence of BPD. EIS monitoring was performed before and 15 min after the administration of 400 µg of salbutamol (pMDI with spacer) in all subjects during spontaneous tidal breathing in upright position. Data were expressed as median segmental impedance amplitude differences and segmental ventilation inhomogeneity index (II) changes. RESULTS We included 51 children in our analysis: 33 with BPD (median birth weight-840 g; median gestational age-27 weeks) and 18 without BPD (1,290 g; 30 weeks, respectively). There was a significant increase in median segmental impedance amplitude after salbutamol in gravity non-dependent segments in children with BPD: upper left (UL): 462 versus 534 AU; (P = 0.003); upper right (UR): 481 versus 595 AU (P < 0.001) and II in these segments: UL: 0.046 versus 0.078 (P = 0.003) UR: 0.049 versus 0.064 (P = 0.006). There were no changes in the lower segments. There were no changes in ventilation pattern in children without BPD. CONCLUSION BDR to salbutamol increases breath amplitude in gravity non-dependent segments of the lungs during spontaneous tidal breathing in preschool children with BPD. Pediatr Pulmonol. 2017;52:353-359. © 2016 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Wojciech Durlak
- Department of Pediatrics, Jagiellonian University, Wielicka 265, Cracow, 30-663, Poland
| | - Małgorzata Klimek
- Department of Pediatrics, Jagiellonian University, Wielicka 265, Cracow, 30-663, Poland
| | - Przemko Kwinta
- Department of Pediatrics, Jagiellonian University, Wielicka 265, Cracow, 30-663, Poland
| |
Collapse
|
21
|
Frerichs I, Golisch W, Hahn G, Michael K, Burchardi H, Hellige G. Heterogeneous Distribution of Pulmonary Ventilation in Intensive Care Patients Detected by Functional Electrical Impedance Tomography. J Intensive Care Med 2016. [DOI: 10.1177/088506669801300404] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Electrical impedance tomography (EIT) is a new noninvasive imaging technique which utilizes the different electrical properties of biological tissues to produce cross-sectional images of selected parts of the body. When applied on the thorax, the cyclic fluctuations of electrical impedance of the lung tissue, associated with different air contents of the lungs in the course of the respiratory cycle, can be used to generate derived EIT tomograms which represent the spatial distribution of ventilation in the chosen transverse plane. The corresponding evaluation technique, the functional EIT, was used for the first time to follow the regional ventilation in three intensive care patients. The method was shown (1) to identify the redistribution of inspired air in the lungs associated with controlled ventilation in a patient undergoing elective laparotomy, (2) to follow the improvement of locally impaired lung ventilation in the course of severe pneumonia, and (3) to detect regional reduction of ventilation due to lobar atelectasis with stasis pneumonia in a patient with bronchial carcinoma.
Collapse
Affiliation(s)
- Inéz Frerichs
- Department of Anesthesiological Research, University of Göttingen, Göttingen, Germany
| | - Wolfgang Golisch
- Department of Anesthesiological Research, University of Göttingen, Göttingen, Germany
| | - Günter Hahn
- Department of Anesthesiological Research, University of Göttingen, Göttingen, Germany
| | - Kurpitz Michael
- Department of Anesthesiological Research, University of Göttingen, Göttingen, Germany
| | - Hilmar Burchardi
- Department of Anesthesiological Research, University of Göttingen, Göttingen, Germany
| | - Gerhard Hellige
- Department of Anesthesiological Research, University of Göttingen, Göttingen, Germany
| |
Collapse
|
22
|
Cambiaghi B, Moerer O, Kunze-Szikszay N, Mauri T, Just A, Dittmar J, Hahn G. A spiky pattern in the course of electrical thoracic impedance as a very early sign of a developing pneumothorax. Clin Physiol Funct Imaging 2016; 38:158-162. [PMID: 27619316 DOI: 10.1111/cpf.12385] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2016] [Accepted: 07/11/2016] [Indexed: 11/29/2022]
Abstract
A pneumothorax (PTX) is a potentially lethal condition in high-risk intensive care patients. Electrical impedance tomography (EIT) has been proven to detect PTX at the bedside. A so far not described pattern in the course of thoracic impedance at an early state of PTX was observed in a pig model of ventilator-induced lung injury (VILI) used for a more extensive study. EIT was performed at a framerate of 50 Hz. Beginning of PTX at normal ventilation, manifestation of PTX at VILI ventilation (plateau pressure 42 cm H2 O) and final pleural drainage were documented. At ventilation with 8·6 ml kg-1 , early PTX findings prior to any clinical deterioration consisted in a spike-like pattern in the time course of impedance (relative impedance change referred to initial end-expiratory level). Spike amplitudes (mean ± SD) were the following: 0·154 ± 0·059 (right lung) and 0·048 ± 0·050 (left lung). At this state, end-expiratory levels (mean ± SD) were still similar, -0·035 ± 0·010 (right) and -0·058 ± 0·022 (left). After application of VILI ventilation (38 ml kg-1 ), a PTX developed slowly, being confirmed by a continuous increase in the end-expiratory level on the right side and diverging levels of +0·320 ± 0·057 (right) and -0·193 ± 0·147 (left) at full manifestation. We assume that spikes reflect a temporary change in the electrical pathway caused by leakage into the pleural cavity. This newly described phenomenon of spikes is considered to be a potentially useful indicator for a very early detection of an evolving PTX in high-risk ICU patients.
Collapse
Affiliation(s)
- B Cambiaghi
- Dipartimento di Medicina e Chirurgia, Università Degli Studi Milano-Bicocca, Monza (MB), Italy
| | - O Moerer
- Department of Anesthesiology, University Medical Center Goettingen, Goettingen, Germany
| | - N Kunze-Szikszay
- Department of Anesthesiology, University Medical Center Goettingen, Goettingen, Germany
| | - T Mauri
- Department of Anesthesiology, Intensive Care and Emergency Medicine IRCCS Ca' Granda Foundation, Hospital Maggiore Policlinico di Milano, Milan, Italy
| | - A Just
- Department of Anesthesiology, University Medical Center Goettingen, Goettingen, Germany
| | - J Dittmar
- Department of Anesthesiology, University Medical Center Goettingen, Goettingen, Germany
| | - G Hahn
- Department of Anesthesiology, University Medical Center Goettingen, Goettingen, Germany
| |
Collapse
|
23
|
Horses Auto-Recruit Their Lungs by Inspiratory Breath Holding Following Recovery from General Anaesthesia. PLoS One 2016; 11:e0158080. [PMID: 27331910 PMCID: PMC4917253 DOI: 10.1371/journal.pone.0158080] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2015] [Accepted: 06/09/2016] [Indexed: 11/19/2022] Open
Abstract
This study evaluated the breathing pattern and distribution of ventilation in horses prior to and following recovery from general anaesthesia using electrical impedance tomography (EIT). Six horses were anaesthetised for 6 hours in dorsal recumbency. Arterial blood gas and EIT measurements were performed 24 hours before (baseline) and 1, 2, 3, 4, 5 and 6 hours after horses stood following anaesthesia. At each time point 4 representative spontaneous breaths were analysed. The percentage of the total breath length during which impedance remained greater than 50% of the maximum inspiratory impedance change (breath holding), the fraction of total tidal ventilation within each of four stacked regions of interest (ROI) (distribution of ventilation) and the filling time and inflation period of seven ROI evenly distributed over the dorso-ventral height of the lungs were calculated. Mixed effects multi-linear regression and linear regression were used and significance was set at p<0.05. All horses demonstrated inspiratory breath holding until 5 hours after standing. No change from baseline was seen for the distribution of ventilation during inspiration. Filling time and inflation period were more rapid and shorter in ventral and slower and longer in most dorsal ROI compared to baseline, respectively. In a mixed effects multi-linear regression, breath holding was significantly correlated with PaCO2 in both the univariate and multivariate regression. Following recovery from anaesthesia, horses showed inspiratory breath holding during which gas redistributed from ventral into dorsal regions of the lungs. This suggests auto-recruitment of lung tissue which would have been dependent and likely atelectic during anaesthesia.
Collapse
|
24
|
Lehmann S, Leonhardt S, Ngo C, Bergmann L, Schrading S, Heimann K, Wagner N, Tenbrock K. Electrical impedance tomography as possible guidance for individual positioning of patients with multiple lung injury. CLINICAL RESPIRATORY JOURNAL 2016; 12:68-75. [PMID: 27058971 DOI: 10.1111/crj.12481] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2015] [Revised: 03/08/2016] [Accepted: 03/31/2016] [Indexed: 11/26/2022]
Abstract
INTRODUCTION Electrical Impedance Tomography (EIT) is a tomographic, radiation-free technique based on the injection of a harmless alternating current. OBJECTIVE As electrical impedance strictly correlates with the variation of air content, EIT delivers highly dynamic information about global and regional ventilation. We want to demonstrate the potential of EIT individualizing ventilation by positioning. METHODS Gravity-dependent EIT findings were analyzed retrospectively in a critically ill mechanically ventilated pediatric patient with cystic fibrosis and coincident lung diseases. To further evaluate gravity-dependent changes in ventilation, six adult healthy and spontaneously breathing volunteers were investigated during simultaneous detection of EIT, breathing patterns, tidal volume (VT) and breathing frequency (BF). RESULTS EIT findings in healthy lungs in five positions showed gravity-dependent effects of ventilation with overall ventilation of predominantly the right lung (except during left-side positioning) and with the ventral lung in supine, prone and upright position. These EIT-derived observations are in line with pathophysiological mechanisms and earlier EIT studies. Unexpectedly, the patient with cystic fibrosis and lobectomy of the right upper and middle lobe one year earlier, showed improvement of global and regional ventilation in the right position despite reduced lung volume and overinflation of this side. This resulted in individualized positioning and improvement of ventilation. CONCLUSIONS Although therapeutic recommendations are available for gravitational influences of lung ventilation, they can be contradictory depending on the underlying lung disease. EIT has the potential to guide therapists in the positioning of patients according to their individual condition and disease, especially in case of multiple lung injury.
Collapse
Affiliation(s)
- Sylvia Lehmann
- Department of Pediatrics, Division Pediatric Pulmonology, University Hospital RWTH Aachen, Aachen, Germany
| | - Steffen Leonhardt
- Philips Chair for Medical Information Technology, RWTH Aachen, Aachen, Germany
| | - Chuong Ngo
- Philips Chair for Medical Information Technology, RWTH Aachen, Aachen, Germany
| | - Lukas Bergmann
- Philips Chair for Medical Information Technology, RWTH Aachen, Aachen, Germany
| | - Simone Schrading
- Department of Radiology, University Hospital RWTH Aachen, Aachen, Germany
| | - Konrad Heimann
- Department of Pediatrics, Division of Neonatology, University Hospital RWTH Aachen, Aachen, Germany
| | - Norbert Wagner
- Department of Pediatrics, Division Pediatric Pulmonology, University Hospital RWTH Aachen, Aachen, Germany
| | - Klaus Tenbrock
- Department of Pediatrics, Division Pediatric Pulmonology, University Hospital RWTH Aachen, Aachen, Germany
| |
Collapse
|
25
|
Kobylianskii J, Murray A, Brace D, Goligher E, Fan E. Electrical impedance tomography in adult patients undergoing mechanical ventilation: A systematic review. J Crit Care 2016; 35:33-50. [PMID: 27481734 DOI: 10.1016/j.jcrc.2016.04.028] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2016] [Revised: 04/25/2016] [Accepted: 04/27/2016] [Indexed: 01/20/2023]
Abstract
PURPOSE The purpose of the study is to systematically review and summarize current literature concerning the validation and application of electrical impedance tomography (EIT) in mechanically ventilated adult patients. MATERIALS AND METHODS An electronic search of MEDLINE, EMBASE, CINAHL, Cochrane Central Register of Controlled Trials, and the Web of Science was performed up to June 2014. Studies investigating the use of EIT in an adult human patient population treated with mechanical ventilation (MV) were included. Data extracted included study objectives, EIT details, interventions, MV protocol, validation and comparators, population characteristics, and key findings. RESULTS Of the 67 included studies, 35 had the primary objective of validating EIT measures including regional ventilation distribution, lung volume, regional respiratory mechanics, and nonventilatory parameters. Thirty-two studies had the primary objective of applying EIT to monitor the response to therapeutic MV interventions including change in ventilation mode, patient repositioning, endotracheal suctioning, recruitment maneuvers, and change in positive end-expiratory pressure. CONCLUSIONS In adult patients, EIT has been successfully validated for assessing ventilation distribution, measuring changes in lung volume, studying regional respiratory mechanics, and investigating nonventilatory parameters. Electrical impedance tomography has also been demonstrated to be useful in monitoring regional respiratory system changes during MV interventions, although existing literature lacks clinical outcome evidence.
Collapse
Affiliation(s)
- Jane Kobylianskii
- School of Medicine, Queen's University, Kingston, Canada; Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Canada
| | - Alistair Murray
- Schulich School of Medicine & Dentistry, Western University, London, Canada; Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Canada
| | - Debbie Brace
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Canada
| | - Ewan Goligher
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Canada
| | - Eddy Fan
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Canada.
| |
Collapse
|
26
|
Regional distribution of ventilation in patients with obstructive sleep apnea: the role of thoracic electrical impedance tomography (EIT) monitoring. Sleep Breath 2016; 20:1245-1253. [PMID: 27136936 DOI: 10.1007/s11325-016-1349-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2016] [Revised: 03/29/2016] [Accepted: 04/19/2016] [Indexed: 12/27/2022]
Abstract
PURPOSE The aim of our study was to apply the electrical impedance tomography (EIT) technique to the study of ventilation during wake and NREM and REM sleep in patients with obstructive sleep apneas (OSA). METHODS This is a prospective, observational, monocentric, pilot study in a neurology department with a sleep disorder center. Inclusion criteria were age ≥18 years, both gender, and diagnosis of OSA. Exclusion criteria were the contraindications to the thoracic EIT. All patients underwent laboratory-based polysomnography (PSG) alongside thoracic EIT. Primary endpoint was to compare the global impedance (GI) among the conditions: "Wake" vs "Sleep," "NREM" vs "REM," and "OSA" vs "Non-OSA." Secondary endpoint was to measure the regional distribution of impedance in the four regions of interest (ROIs), in each condition. RESULTS Of the 17 consecutive patients enrolled, two were excluded because of poor-quality EIT tracings. Fifteen were analyzed, 10 men and 5 women, mean age 51.6 ± 14.4 years. GI was higher in Wake vs Sleep (Wake 13.24 ± 11.23; Sleep 12.56 ± 13.36; p < 0.01), in NREM vs REM (NREM 13.48 ± 13.43; REM 0.59 ± 0.01; p < 0.01), and in Non-OSA vs OSA (Non-OSA 10.50 ± 12.99; OSA 18.98 ± 10.06; p < 0.01). No significant differences were observed in the regional distribution of impedance between Wake and Sleep (χ 2 = 3.66; p = 0.299) and between Non-OSA and OSA (χ 2 = 1.00; p = 0.799); conversely, a significant difference was observed between NREM and REM sleep (χ 2 = 62.94; p < 0.001). CONCLUSIONS To our knowledge, this is the first study that addresses the issue of regional ventilation in OSA patients during sleep. Thoracic electrical impedance changes through the sleep-wake cycle and during obstructive events. The application of thoracic EIT can prove a valuable additional strategy for the evaluation of OSA patients.
Collapse
|
27
|
Sirevaag EJ, Casaccia S, Richter EA, O'Sullivan JA, Scalise L, Rohrbaugh JW. Cardiorespiratory interactions: Noncontact assessment using laser Doppler vibrometry. Psychophysiology 2016; 53:847-67. [PMID: 26970208 DOI: 10.1111/psyp.12638] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2015] [Accepted: 01/17/2016] [Indexed: 01/02/2023]
Abstract
The application of a noncontact physiological recording technique, based on the method of laser Doppler vibrometry (LDV), is described. The effectiveness of the LDV method as a physiological recording modality lies in the ability to detect very small movements of the skin, associated with internal mechanophysiological activities. The method is validated for a range of cardiovascular variables, extracted from the contour of the carotid pulse waveform as a function of phase of the respiration cycle. Data were obtained from 32 young healthy participants, while resting and breathing spontaneously. Individual beats were assigned to four segments, corresponding with inspiration and expiration peaks and transitional periods. Measures relating to cardiac and vascular dynamics are shown to agree with the pattern of effects seen in the substantial body of literature based on human and animal experiments, and with selected signals recorded simultaneously with conventional sensors. These effects include changes in heart rate, systolic time intervals, and stroke volume. There was also some evidence for vascular adjustments over the respiration cycle. The effectiveness of custom algorithmic approaches for extracting the key signal features was confirmed. The advantages of the LDV method are discussed in terms of the metrological properties and utility in psychophysiological research. Although used here within a suite of conventional sensors and electrodes, the LDV method can be used on a stand-alone, noncontact basis, with no requirement for skin preparation, and can be used in harsh environments including the MR scanner.
Collapse
Affiliation(s)
- Erik J Sirevaag
- Department of Psychiatry, Washington University School of Medicine, St. Louis, Missouri, USA
| | - Sara Casaccia
- Preston M. Green Department of Electrical and Systems Engineering, School of Engineering, Washington University in St. Louis, St. Louis, Missouri, USA.,Department of Industrial Engineering and Mathematical Science, Università Politecnica delle Marche, Ancona, Italy
| | - Edward A Richter
- Preston M. Green Department of Electrical and Systems Engineering, School of Engineering, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Joseph A O'Sullivan
- Preston M. Green Department of Electrical and Systems Engineering, School of Engineering, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Lorenzo Scalise
- Department of Industrial Engineering and Mathematical Science, Università Politecnica delle Marche, Ancona, Italy
| | - John W Rohrbaugh
- Department of Psychiatry, Washington University School of Medicine, St. Louis, Missouri, USA
| |
Collapse
|
28
|
Sharma H, Sharma K, Bhagat OL. Respiratory rate extraction from single-lead ECG using homomorphic filtering. Comput Biol Med 2015; 59:80-86. [DOI: 10.1016/j.compbiomed.2015.01.024] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2014] [Revised: 01/27/2015] [Accepted: 01/30/2015] [Indexed: 11/16/2022]
|
29
|
Changes in lung volume and ventilation following transition from invasive to noninvasive respiratory support and prone positioning in preterm infants. Pediatr Res 2015; 77:484-8. [PMID: 25518010 DOI: 10.1038/pr.2014.201] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2014] [Accepted: 09/20/2014] [Indexed: 11/08/2022]
Abstract
BACKGROUND To minimize secondary lung injury, ventilated preterm infants are extubated as soon as possible. To maximize extubation success, they are often placed in prone position. The effect of extubation and subsequent prone positioning on lung volumes is currently unknown. METHODS Changes in end-expiratory lung volume (ΔEELV), tidal volume (VT), and ventilation distribution were monitored during transition from endotracheal to nasal continuous positive airway pressure and following prone positioning using electrical impedance tomography. In addition, the continuous distending pressure (CDP) and oxygen need (FiO₂) were recorded. RESULTS Twenty preterm infants (GA 28.7 ± 1.7 wk) were included. Following extubation, the CDP decreased from 7.9 ± 0.5 to 6.0 ± 0.2 cmH₂O, while the FiO₂ remained stable. Both ΔEELV and VT increased significantly (P < 0.05) after extubation, without changing ventilation distribution. Prone positioning resulted in a further increase in ΔEELV (P < 0.01) and a decrease in respiratory rate. VT remained stable but its distribution clearly shifted toward the ventral lung regions. CONCLUSION Infants who are transitioned from invasive to noninvasive respiratory support are able to maintain their EELV and increase their VT. Prone positioning increases EELV and shifts tidal ventilation to the ventral lung regions. The latter suggests that infants should preferably be placed in prone position after extubation.
Collapse
|
30
|
Monitoring Lung Volumes During Mechanical Ventilation. PEDIATRIC AND NEONATAL MECHANICAL VENTILATION 2015. [PMCID: PMC7193716 DOI: 10.1007/978-3-642-01219-8_14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Respiratory inductive plethysmography (RIP) is a non-invasive method of measuring change in lung volume which is well-established as a monitor of tidal ventilation and thus respiratory patterns in sleep medicine. As RIP is leak independent, can measure end-expiratory lung volume as well as tidal volume and is applicable to both the ventilated and spontaneously breathing patient, there has been a recent interest in its use as a bedside tool in the intensive care unit.
Collapse
|
31
|
Bodenstein M, Boehme S, Wang H, Duenges B, Markstaller K. Hints for cyclical recruitment of atelectasis during ongoing mechanical ventilation in lavage and oleic acid lung injury detected by SpO₂ oscillations and electrical impedance tomography. Exp Lung Res 2014; 40:427-38. [PMID: 25153803 DOI: 10.3109/01902148.2014.944719] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE OF THE STUDY Detection of cyclical recruitment of atelectasis after induction of lavage (LAV) or oleic acid injury (OAI) in mechanically ventilated pigs. Primary hypothesis is that oxygen oscillations within the respiratory cycle can be detected by SpO₂ recordings (direct hint). SpO₂ oscillations reflect shunt oscillations that can only be explained by cyclical recruitment of atelectasis. Secondary hypothesis is that electrical impedance tomography (EIT) depicts specific regional changes of lung aeration and of pulmonary mechanical properties (indirect hint). MATERIALS AND METHODS Three groups (each n = 7) of mechanically ventilated pigs were investigated applying above mentioned methods before and repeatedly after induction of lung injury: (1) sham treated animals (SHAM), (2) LAV, and (3) OAI. RESULTS Early oxygen oscillations occurred in the LAV group (mean calculated amplitude: 73.8 mmHg reflecting shunt oscillation of 11.2% in mean). In the OAI group oxygen oscillations occurred hours after induction of lung injury (mean calculated amplitude: 57.1 mmHg reflecting shunt oscillations of 8.4% in mean). The SHAM group had no relevant oxygen oscillations (<30 mmHg, shunt oscillations < 1.5%). Synchronously to oxygen oscillations, EIT depicted (1) a decrease of ventilation in dorsal areas, (2) an increase in ventral areas, (3) a decrease of especially dependent expiratory impedance, 3) an increase in late inspiratory flow especially in the dependant areas, (4) an increase in the speed of peak expiratory flow (PEF), and (5) a decrease of dorsal late expiratory flow. CONCLUSIONS SpO2 and EIT recordings detect events that are interpreted as cyclical recruitment of atelectasis.
Collapse
Affiliation(s)
- Marc Bodenstein
- 1Department of Anaesthesiology, University Medical Center Mainz, Mainz, Germany
| | | | | | | | | |
Collapse
|
32
|
Monitoring of regional lung ventilation using electrical impedance tomography after cardiac surgery in infants and children. Pediatr Cardiol 2014; 35:990-7. [PMID: 24569885 DOI: 10.1007/s00246-014-0886-6] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2013] [Accepted: 02/06/2014] [Indexed: 02/05/2023]
Abstract
Electrical impedance tomography (EIT) is a noninvasive method to monitor regional lung ventilation in infants and children without using radiation. The objective of this prospective study was to determine the value of EIT as an additional monitoring tool to assess regional lung ventilation after pediatric cardiac surgery for congenital heart disease in infants and children. EIT monitoring was performed in a prospective study comprising 30 pediatric patients who were mechanically ventilated after cardiac surgery. Data were analyzed off-line with respect to regional lung ventilation in different clinical situations. EIT data were correlated with respirator settings and arterial carbon dioxide (CO2) partial pressure in the blood. In 29 of 30 patients, regional ventilation of the lung could sufficiently and reliably be monitored by means of EIT. The effects of the transition from mechanical ventilation to spontaneous breathing after extubation on regional lung ventilation were studied. After extubation, a significant decrease of relative impedance changes was evident. In addition, a negative correlation of arterial CO2 partial pressure and relative impedance changes could be shown. EIT was sufficient to discriminate differences of regional lung ventilation in children and adolescents after cardiac surgery. EIT reliably provided additional information on regional lung ventilation in children after cardiac surgery. Neither chest tubes nor pacemaker wires nor the intensive care unit environment interfered with the application of EIT. EIT therefore may be used as an additional real-time monitoring tool in pediatric cardiac intensive care because it is noninvasive.
Collapse
|
33
|
Cross-Sectional Changes in Lung Volume Measured by Electrical Impedance Tomography Are Representative for the Whole Lung in Ventilated Preterm Infants. Crit Care Med 2014; 42:1524-30. [DOI: 10.1097/ccm.0000000000000230] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
34
|
Bodenstein M, Boehme S, Bierschock S, Vogt A, David M, Markstaller K. Determination of respiratory gas flow by electrical impedance tomography in an animal model of mechanical ventilation. BMC Pulm Med 2014; 14:73. [PMID: 24779960 PMCID: PMC4012093 DOI: 10.1186/1471-2466-14-73] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2013] [Accepted: 03/28/2014] [Indexed: 01/10/2023] Open
Abstract
Background A recent method determines regional gas flow of the lung by electrical impedance tomography (EIT). The aim of this study is to show the applicability of this method in a porcine model of mechanical ventilation in healthy and diseased lungs. Our primary hypothesis is that global gas flow measured by EIT can be correlated with spirometry. Our secondary hypothesis is that regional analysis of respiratory gas flow delivers physiologically meaningful results. Methods In two sets of experiments n = 7 healthy pigs and n = 6 pigs before and after induction of lavage lung injury were investigated. EIT of the lung and spirometry were registered synchronously during ongoing mechanical ventilation. In-vivo aeration of the lung was analysed in four regions-of-interest (ROI) by EIT: 1) global, 2) ventral (non-dependent), 3) middle and 4) dorsal (dependent) ROI. Respiratory gas flow was calculated by the first derivative of the regional aeration curve. Four phases of the respiratory cycle were discriminated. They delivered peak and late inspiratory and expiratory gas flow (PIF, LIF, PEF, LEF) characterizing early or late inspiration or expiration. Results Linear regression analysis of EIT and spirometry in healthy pigs revealed a very good correlation measuring peak flow and a good correlation detecting late flow. PIFEIT = 0.702 · PIFspiro + 117.4, r2 = 0.809; PEFEIT = 0.690 · PEFspiro-124.2, r2 = 0.760; LIFEIT = 0.909 · LIFspiro + 27.32, r2 = 0.572 and LEFEIT = 0.858 · LEFspiro-10.94, r2 = 0.647. EIT derived absolute gas flow was generally smaller than data from spirometry. Regional gas flow was distributed heterogeneously during different phases of the respiratory cycle. But, the regional distribution of gas flow stayed stable during different ventilator settings. Moderate lung injury changed the regional pattern of gas flow. Conclusions We conclude that the presented method is able to determine global respiratory gas flow of the lung in different phases of the respiratory cycle. Additionally, it delivers meaningful insight into regional pulmonary characteristics, i.e. the regional ability of the lung to take up and to release air.
Collapse
Affiliation(s)
- Marc Bodenstein
- Department of Anaesthesiology, University Medical Center Mainz, Mainz 55101, Germany.
| | | | | | | | | | | |
Collapse
|
35
|
Assessment of regional ventilation distribution: comparison of vibration response imaging (VRI) with electrical impedance tomography (EIT). PLoS One 2014; 9:e86638. [PMID: 24475160 PMCID: PMC3903564 DOI: 10.1371/journal.pone.0086638] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2013] [Accepted: 12/11/2013] [Indexed: 11/21/2022] Open
Abstract
Background Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation. Methodology/Principal Findings Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) by EIT, were evaluated in seven regions of interest (ROIs). To assess the distribution of tidal volume (VT) by VRI and EIT, absolute values were normalized to the VT obtained by simultaneous spirometry measurements. Redistribution of ventilation by ALI and PEEP was detected by VRI and EIT. The linear correlation between pooled VT by VEA and rel.ΔZ was R2 = 0.96. Bland-Altman analysis showed a bias of −1.07±24.71 ml and limits of agreement of −49.05 to +47.36 ml. Within the different ROIs, correlations of VT-distribution by EIT and VRI ranged between R2 values of 0.29 and 0.96. ALI and PEEP did not alter the agreement of VT between VRI and EIT. Conclusions/Significance Measurements of regional ventilation distribution by VRI are comparable to those obtained by EIT.
Collapse
|
36
|
Role of electrical impedance tomography in clinical practice in pediatric respiratory medicine. ISRN PEDIATRICS 2013; 2013:529038. [PMID: 24455294 PMCID: PMC3886230 DOI: 10.1155/2013/529038] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 10/31/2013] [Accepted: 12/08/2013] [Indexed: 11/18/2022]
Abstract
This paper summarizes current knowledge about electrical impedance tomography (EIT) and its present and possible applications in clinical practice in pediatric respiratory medicine. EIT is a relatively new technique based on real-time monitoring of bioimpedance. Its possible application in clinical practice related to ventilation and perfusion monitoring in children has gaine increasing attention in recent years. Most of the currently published data is based on studies performed on small and heterogenous groups of patients. Thus the results need to be corroborated in future well-designed clinical trials. Firstly a short theoretical overview summarizing physical principles and main advantages and disadvantages is provided. It is followed by a review of the current data regarding EIT application in ventilation distribution monitoring in healthy individuals. Finally the most important studies utilizing EIT in ventilation and perfusion monitoring in critically ill newborns and children are outlined.
Collapse
|
37
|
Hahn G, Just A, Hellige G, Dittmar J, Quintel M. How absolute EIT reflects the dependence of unilateral lung aeration on hyper-gravity and weightlessness? Physiol Meas 2013; 34:1063-74. [DOI: 10.1088/0967-3334/34/9/1063] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
38
|
Burkhardt W, Kurth F, Pitterle M, Blassnig N, Wemhöner A, Rüdiger M. Continuous noninvasive monitoring of lung recruitment during high-frequency oscillatory ventilation by electrical impedance measurement: an animal study. Neonatology 2013; 103:218-23. [PMID: 23364000 DOI: 10.1159/000345612] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2012] [Accepted: 11/05/2012] [Indexed: 11/19/2022]
Abstract
BACKGROUND Ventilatory pressures should target the range between the upper and lower inflection point of the pressure volume curve in order to avoid atelecto- and volutrauma. During high-frequency oscillatory ventilation (HFOV), this range is difficult to determine. Quadrant impedance measurement (QIM) has recently been shown to allow accurate and precise measurement of lung volume changes during conventional mechanical ventilation. OBJECTIVES To investigate if QIM can be used to determine a static pressure-residual impedance curve during a recruitment-derecruitment manoeuvre on HFOV and to monitor the time course of alveolar recruitment after changing mean airway pressure (MAP). METHODS An incremental and decremental MAP trial (6 cm H2O to 27 cm H2O) was conducted in five surfactant-depleted newborn piglets during HFOV. Ventilatory, gas exchange and haemodynamic parameters were recorded. Continuous measurement of thoracic impedance change was performed. RESULTS Mean residual impedance (RI) increased with each stepwise increase of MAP resulting in a total mean increase of +26.5% (±4.0) at the highest MAP (27 cm H2O) compared to baseline ventilation at 6 cm H2O. Upon decreasing MAP levels, RI fell more slowly compared to its ascent; 83.4% (±19.1) and 84.8% (±16.4) of impedance changes occurred in the first 5 min after an increase or decrease in airway pressure, respectively. CONCLUSIONS QIM could be used for continuous monitoring of thoracic impedance and determination of the pressure-RI curve during HFOV. The method could prove to be a promising bedside method for the monitoring of lung recruitment during HFOV in the future.
Collapse
Affiliation(s)
- Wolfram Burkhardt
- Department of Neonatology and Paediatric Intensive Care, University Hospital Carl Gustav Carus Dresden, Dresden, Germany
| | | | | | | | | | | |
Collapse
|
39
|
Ferrario D, Grychtol B, Adler A, Sola J, Bohm SH, Bodenstein M. Toward Morphological Thoracic EIT: Major Signal Sources Correspond to Respective Organ Locations in CT. IEEE Trans Biomed Eng 2012; 59:3000-8. [DOI: 10.1109/tbme.2012.2209116] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
40
|
Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring? Intensive Care Med 2012; 38:1917-29. [DOI: 10.1007/s00134-012-2684-z] [Citation(s) in RCA: 87] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2011] [Accepted: 08/08/2012] [Indexed: 01/08/2023]
|
41
|
Dunster KR, Friese M, Fraser JF, Cowin GJ, Schibler A. Ventilation distribution in rats: Part I--The effect of gas composition as measured with electrical impedance tomography. Biomed Eng Online 2012; 11:64. [PMID: 22947026 PMCID: PMC3497876 DOI: 10.1186/1475-925x-11-64] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2012] [Accepted: 08/22/2012] [Indexed: 11/17/2022] Open
Abstract
Abstract The measurement of ventilation distribution is currently performed using inhaled tracer gases for multiple breath inhalation studies or imaging techniques to quantify spatial gas distribution. Most tracer gases used for these studies have properties different from that of air. The effect of gas density on regional ventilation distribution has not been studied. This study aimed to measure the effect of gas density on regional ventilation distribution. Methods Ventilation distribution was measured in seven rats using electrical impedance tomography (EIT) in supine, prone, left and right lateral positions while being mechanically ventilated with either air, heliox (30% oxygen, 70% helium) or sulfur hexafluoride (20% SF6, 20% oxygen, 60% air). The effect of gas density on regional ventilation distribution was assessed. Results Gas density did not impact on regional ventilation distribution. The non-dependent lung was better ventilated in all four body positions. Gas density had no further impact on regional filling characteristics. The filling characteristics followed an anatomical pattern with the anterior and left lung showing a greater impedance change during the initial phase of the inspiration. Conclusion It was shown that gas density did not impact on convection dependent ventilation distribution in rats measured with EIT.
Collapse
Affiliation(s)
- Kimble R Dunster
- Paediatric Critical Care Research Group, Paediatric Intensive Care Unit, Mater Children's Hospital, South Brisbane, QLD, Australia.
| | | | | | | | | |
Collapse
|
42
|
Schnidrig S, Casaulta C, Schibler A, Riedel T. Influence of end-expiratory level and tidal volume on gravitational ventilation distribution during tidal breathing in healthy adults. Eur J Appl Physiol 2012; 113:591-8. [PMID: 22872368 DOI: 10.1007/s00421-012-2469-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2012] [Accepted: 07/25/2012] [Indexed: 10/27/2022]
Abstract
Our understanding of regional filling of the lung and regional ventilation distribution is based on studies using stepwise inhalation of radiolabelled tracer gases, magnetic resonance imaging and positron emission tomography. We aimed to investigate whether these differences in ventilation distribution at different end-expiratory levels (EELs) and tidal volumes (V (T)s) held also true during tidal breathing. Electrical impedance tomography (EIT) measurements were performed in ten healthy adults in the right lateral position. Five different EELs with four different V (T)s at each EEL were tested in random order, resulting in 19 combinations. There were no measurements for the combination of the highest EEL/highest V (T). EEL and V (T) were controlled by visual feedback based on airflow. The fraction of ventilation directed to different slices of the lung (VENT(RL1)-VENT(RL8)) and the rate of the regional filling of each slice versus the total lung were analysed. With increasing EEL but normal tidal volume, ventilation was preferentially distributed to the dependent lung and the filling of the right and left lung was more homogeneous. With increasing V (T) and maintained normal EEL (FRC), ventilation was preferentially distributed to the dependent lung and regional filling became more inhomogeneous (p < 0.05). We could demonstrate that regional and temporal ventilation distribution during tidal breathing was highly influenced by EEL and V (T).
Collapse
Affiliation(s)
- Silvia Schnidrig
- Division of Paediatric and Neonatal Intensive Care Medicine, Department of Paediatrics, Inselspital, University Children's Hospital and University of Bern, 3010 Bern, Switzerland
| | | | | | | |
Collapse
|
43
|
Czaplik M, Biener I, Dembinski R, Pelosi P, Soodt T, Schroeder W, Leonhardt S, Marx G, Rossaint R, Bickenbach J. Analysis of regional compliance in a porcine model of acute lung injury. Respir Physiol Neurobiol 2012; 184:16-26. [PMID: 22820182 DOI: 10.1016/j.resp.2012.07.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2012] [Revised: 07/11/2012] [Accepted: 07/12/2012] [Indexed: 11/25/2022]
Abstract
Lung protective ventilation in acute lung injury (ALI) focuses on using low tidal volumes and adequate levels of positive end-expiratory pressure (PEEP). Identifying optimal pressure is difficult because pressure-volume (PV) relations differ regionally. Precise analysis demands local measurements of pressures and related alveolar morphologies. In a porcine model of surfactant depletion (n=24), we combined measuring static pressures with endoscopic microscopy and electrical impedance tomography (EIT) to examine regional PV loops and morphologic heterogeneities between healthy (control group; CON) and ALI lungs ventilated with low (LVT) or high tidal volumes (HVT). Quantification included indices for microscopy (Volume Air Index (VAI), Heterogeneity and Circularity Index), EIT analysis and calculation of regional compliances due to generated PV loops. We found that: (1) VAI decreased in lower lobe after ALI, (2) electrical impedance decreased in dorsal regions and (3) PV loops differed regionally. Further studies should prove the potentials of these techniques on individual respiratory settings and clinical outcome.
Collapse
Affiliation(s)
- Michael Czaplik
- Department of Anesthesiology, University Hospital RWTH, Aachen, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
44
|
Bodenstein M, Wang H, Boehme S, Vogt A, Kwiecien R, David M, Markstaller K. Influence of crystalloid and colloid fluid infusion and blood withdrawal on pulmonary bioimpedance in an animal model of mechanical ventilation. Physiol Meas 2012; 33:1225-36. [PMID: 22735353 DOI: 10.1088/0967-3334/33/7/1225] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Electrical impedance tomography (EIT) is considered useful for monitoring regional ventilation and aeration in intensive-care patients during mechanical ventilation. Changes in their body fluid state modify the electrical properties of lung tissue and may interfere with the EIT measurements of lung aeration. The aim of our study was to assess the effects of crystalloid and colloid infusion and blood withdrawal on bioimpedance determined by EIT in a chest cross-section. Fourteen anaesthetized mechanically ventilated pigs were subjected to interventions affecting the volume state (crystalloid and colloid infusion, blood withdrawal). Six animals received additional crystalloid fluids (fluid group) whereas eight did not (no-fluid group). Global and regional relative impedance changes (RIC, dimensionless unit) were determined by backprojection at end-expiration. Regional ventilation distribution was analyzed by calculating the tidal RIC in the same regions. Colloid infusion led to a significant fall in the global end-expiratory RIC (mean differences: fluid: -91.2, p < 0.001, no-fluid: -38.9, p < 0.001), which was partially reversed after blood withdrawal (mean differences, fluid: +45.1, p = 0.047 and no-fluid: +26.2, p = 0.009). The RIC was significantly lower in the animals with additional crystalloids (mean group difference: 45.5, p < 0.001). Global and regional tidal volumes were not significantly affected by the fluid and volume states.
Collapse
Affiliation(s)
- Marc Bodenstein
- Department of Anaesthesiology, University Medical Centre, 55101 Mainz, Germany.
| | | | | | | | | | | | | |
Collapse
|
45
|
Schramel J, Nagel C, Auer U, Palm F, Aurich C, Moens Y. Distribution of ventilation in pregnant Shetland ponies measured by Electrical Impedance Tomography. Respir Physiol Neurobiol 2012; 180:258-62. [DOI: 10.1016/j.resp.2011.11.018] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2011] [Revised: 11/10/2011] [Accepted: 11/30/2011] [Indexed: 10/14/2022]
|
46
|
Reifferscheid F, Elke G, Pulletz S, Gawelczyk B, Lautenschläger I, Steinfath M, Weiler N, Frerichs I. Regional ventilation distribution determined by electrical impedance tomography: reproducibility and effects of posture and chest plane. Respirology 2011; 16:523-31. [PMID: 21261780 DOI: 10.1111/j.1440-1843.2011.01929.x] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND AND OBJECTIVE Reliable assessment of regional lung ventilation and good reproducibility of electrical impedance tomography (EIT) data are the prerequisites for the future application of EIT in a clinical setting. The aims of our study were to determine (i) the reproducibility of repeated EIT measurements and (ii) the effect of the studied transverse chest plane on ventilation distribution in different postures. METHODS Ten healthy adult subjects were studied in three postures on two separate days. EIT and spirometric data were obtained during tidal breathing and slow vital capacity (VC) manoeuvres. EIT data were acquired in two chest planes at 13 scans/s. Reproducibility of EIT findings was assessed by Bland-Altman analysis and Pearson correlation in 16 regions of interest in each plane. Regional ventilation distribution during tidal breathing and deep expiration was determined as fractional ventilation in four quadrants of the studied chest cross-sections. RESULTS Our study showed a good reproducibility of EIT measurements repeated after an average time interval of 8 days. Global tidal volumes and VCs determined by spirometry on separate days were not significantly different. Regional ventilation in chest quadrants assessed by EIT was also unaffected. Posture exerted a significant effect on ventilation distribution among the chest quadrants during spontaneous breathing and deep expiration in both planes. The spatial distribution patterns in the two planes were not identical. CONCLUSIONS We conclude that regional EIT ventilation findings are reproducible and recommend that the EIT examination location on the chest is carefully chosen especially during repeated measurements and follow-up.
Collapse
Affiliation(s)
- Florian Reifferscheid
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre Schleswig-Holstein-Campus Kiel, Kiel, Germany
| | | | | | | | | | | | | | | |
Collapse
|
47
|
Miedema M, de Jongh FH, Frerichs I, van Veenendaal MB, van Kaam AH. Changes in Lung Volume and Ventilation during Surfactant Treatment in Ventilated Preterm Infants. Am J Respir Crit Care Med 2011; 184:100-5. [DOI: 10.1164/rccm.201103-0375oc] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
48
|
Riera J, Riu PJ, Casan P, Masclans JR. [Electrical impedance tomography in acute lung injury]. Med Intensiva 2011; 35:509-17. [PMID: 21680060 DOI: 10.1016/j.medin.2011.05.005] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2011] [Revised: 05/01/2011] [Accepted: 05/03/2011] [Indexed: 01/18/2023]
Abstract
Electrical impedance tomography has been described as a new method of monitoring critically ill patients on mechanical ventilation. It has recently gained special interest because of its applicability for monitoring ventilation and pulmonary perfusion. Its bedside and continuous implementation, and the fact that it is a non-ionizing and non-invasive technique, makes it an extremely attractive measurement tool. Likewise, given its ability to assess the regional characteristics of lung structure, it could be considered an ideal monitoring tool in the heterogeneous lung with acute lung injury. This review explains the physical concept of bioimpedance and its clinical application, and summarizes the scientific evidence published to date with regard to the implementation of electrical impedance tomography as a method for monitoring ventilation and perfusion, mainly in the patient with acute lung injury, and other possible applications of the technique in the critically ill patient. The review also summarizes the limitations of the technique and its potential areas of future development.
Collapse
Affiliation(s)
- J Riera
- Servicio de Medicina Intensiva, Hospital Universitario Vall d'Hebron, Vall d'Hebron Institut de Recerca, Universitat Autònoma de Barcelona, Barcelona, España.
| | | | | | | |
Collapse
|
49
|
Elke G, Pulletz S, Schädler D, Zick G, Gawelczyk B, Frerichs I, Weiler N. Measurement of regional pulmonary oxygen uptake—a novel approach using electrical impedance tomography. Physiol Meas 2011; 32:877-86. [DOI: 10.1088/0967-3334/32/7/s11] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
50
|
Leonhardt S, Cordes A, Plewa H, Pikkemaat R, Soljanik I, Moehring K, Gerner HJ, Rupp R. Electric impedance tomography for monitoring volume and size of the urinary bladder. ACTA ACUST UNITED AC 2011; 56:301-7. [DOI: 10.1515/bmt.2011.022] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|