1
|
Cabezudo Ballesteros S, Sanabria Carretero P, Reinoso Barbero F. Review of electrical impedance tomography in the pediatric patient. REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION 2024; 71:479-485. [PMID: 38458492 DOI: 10.1016/j.redare.2024.03.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Accepted: 08/28/2023] [Indexed: 03/10/2024]
Abstract
Electrical impedance tomography (EIT) is a new method of monitoring non-invasive mechanical ventilation, at the bedside and useful in critically ill patients. It allows lung monitoring of ventilation and perfusion, obtaining images that provide information on lung function. It is based on the physical principle of impedanciometry or the body's ability to conduct an electrical current. Various studies have shown its usefulness both in adults and in pediatrics in respiratory distress syndrome, pneumonia and atelectasis in addition to pulmonary thromboembolism and pulmonary hypertension by also providing information on pulmonary perfusion, and may be very useful in perioperative medicine; especially in pediatrics avoiding repetitive imaging tests with ionizing radiation.
Collapse
Affiliation(s)
| | - P Sanabria Carretero
- Servicio de Anestesia y Reanimación, Hospital Universitario La Paz, Madrid, Spain
| | - F Reinoso Barbero
- Servicio de Anestesia y Reanimación, Hospital Universitario La Paz, Madrid, Spain
| |
Collapse
|
2
|
Chen R, Krueger-Ziolek S, Lovas A, Benyó B, Rupitsch SJ, Moeller K. Structural priors represented by discrete cosine transform improve EIT functional imaging. PLoS One 2023; 18:e0285619. [PMID: 37167237 PMCID: PMC10174522 DOI: 10.1371/journal.pone.0285619] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Accepted: 04/26/2023] [Indexed: 05/13/2023] Open
Abstract
Structural prior information can improve electrical impedance tomography (EIT) reconstruction. In this contribution, we introduce a discrete cosine transformation-based (DCT-based) EIT reconstruction algorithm to demonstrate a way to incorporate the structural prior with the EIT reconstruction process. Structural prior information is obtained from other available imaging methods, e.g., thorax-CT. The DCT-based approach creates a functional EIT image of regional lung ventilation while preserving the introduced structural information. This leads to an easier interpretation in clinical settings while maintaining the advantages of EIT in terms of bedside monitoring during mechanical ventilation. Structural priors introduced in the DCT-based approach are of two categories in terms of different levels of information included: a contour prior only differentiates lung and non-lung region, while a detail prior includes information, such as atelectasis, within the lung area. To demonstrate the increased interpretability of the EIT image through structural prior in the DCT-based approach, the DCT-based reconstructions were compared with reconstructions from a widely applied one-step Gauss-Newton solver with background prior and from the advanced GREIT algorithm. The comparisons were conducted both on simulation data and retrospective patient data. In the simulation, we used two sets of forward models to simulate different lung conditions. A contour prior and a detail prior were derived from simulation ground truth. With these two structural priors, the reconstructions from the DCT-based approach were compared with the reconstructions from both the one-step Gauss-Newton solver and the GREIT. The difference between the reconstructions and the simulation ground truth is calculated by the ℓ2-norm image difference. In retrospective patient data analysis, datasets from six lung disease patients were included. For each patient, a detail prior was derived from the patient's CT, respectively. The detail prior was used for the reconstructions using the DCT-based approach, which was compared with the reconstructions from the GREIT. The reconstructions from the DCT-based approach are more comprehensive and interpretable in terms of preserving the structure specified by the priors, both in simulation and retrospective patient data analysis. In simulation analysis, the ℓ2-norm image difference of the DCT-based approach with a contour prior decreased on average by 34% from GREIT and 49% from the Gauss-Newton solver with background prior; for reconstructions of the DCT-based approach with detail prior, on average the ℓ2-norm image difference is 53% less than GREIT and 63% less than the reconstruction with background prior. In retrospective patient data analysis, the reconstructions from both the DCT-based approach and GREIT can indicate the current patient status, but the DCT-based approach yields more interpretable results. However, it is worth noting that the preserved structure in the DCT-based approach is derived from another imaging method, not from the EIT measurement. If the structural prior is outdated or wrong, the result might be misleadingly interpreted, which induces false clinical conclusions. Further research in terms of evaluating the validity of the structural prior and detecting the outdated prior is necessary.
Collapse
Affiliation(s)
- Rongqing Chen
- Institute of Technical Medicine (ITeM), Furtwangen University, Villingen-Schwenningen, Germany
- Faculty of Engineering, University of Freiburg, Freiburg, Germany
| | - Sabine Krueger-Ziolek
- Institute of Technical Medicine (ITeM), Furtwangen University, Villingen-Schwenningen, Germany
| | - András Lovas
- Department of Anaesthesiology and Intensive Therapy, Kiskunhalas Semmelweis Hospital, Kiskunhalas, Hungary
| | - Balázs Benyó
- Department of Control Engineering and Information Technology, Faculty of Electrical Engineering and Informatics, Budapest University of Technology and Economics, Budapest, Hungary
| | | | - Knut Moeller
- Institute of Technical Medicine (ITeM), Furtwangen University, Villingen-Schwenningen, Germany
| |
Collapse
|
3
|
Brabant O, Loroesch S, Adler A, Waldmann AD, Raisis A, Mosing M. Performance evaluation of electrode design and material for a large animal electrical impedance tomography belt. Vet Rec 2022; 191:e2184. [PMID: 36197754 DOI: 10.1002/vetr.2184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 06/14/2022] [Accepted: 08/08/2022] [Indexed: 11/06/2022]
Abstract
BACKGROUND Electrical impedance tomography (EIT) produces lung ventilation images via a thoracic electrode belt. Robust electrode design and material, providing low electrode skin contact impedance (SCI), is needed in veterinary medicine. The aim of this study was to compare three EIT electrode designs and materials. METHODS Simulations of cylindrical, rectangular and spiked electrode designs were used to evaluate electrode SCI as a function of electrode size, where skin contact was uneven. Gold-plated washers (EGW ), zinc-plated rivets (EZR ) and zinc-galvanised spikes (EZS ) were assigned randomly on two interconnected EIT belts. Gel was applied to the cranial or caudal belt and placed on 17 standing cattle. SCI was recorded at baseline and 3, 5, 7, 9 and 11 minutes later. RESULTS Simulations that involved electrodes with a greater skin contact area had lower and more uniform SCI. In cattle, SCI decreased with all electrodes over time (p < 0.01). Without gel, no difference was found between EGW and EZS , while SCI was higher for EZR (p < 0.03). With gel, SCI was lower in EGW and EZR (p < 0.026), with the SCI in EGW being the lowest (p < 0.01). LIMITATIONS Low numbers of animals and static electrode position may affect SCI. CONCLUSIONS Electrode design is important for EIT measurement, with larger electrode designs able to compensate for the use of less conductive materials. Gel is not necessary to achieve acceptable SCI in large animals.
Collapse
Affiliation(s)
- Olivia Brabant
- School of Veterinary and Life Sciences, Murdoch University, Murdoch, Western Australia, Australia
| | - Sarah Loroesch
- School of Veterinary and Life Sciences, Murdoch University, Murdoch, Western Australia, Australia
| | - Andy Adler
- Department of Systems and Computer Engineering, Carleton University, Ottawa, Ontario, Canada
| | - Andreas D Waldmann
- Department of Anaesthesiology and Intensive Care Medicine, Rostock University Medical Centre, Rostock, Germany
| | - Anthea Raisis
- School of Veterinary and Life Sciences, Murdoch University, Murdoch, Western Australia, Australia
| | - Martina Mosing
- School of Veterinary and Life Sciences, Murdoch University, Murdoch, Western Australia, Australia
| |
Collapse
|
4
|
McAlinden BM, Hough JL, Kuys S. Measuring the effects of airway clearance in mechanically ventilated infants and children: A systematic review. Physiotherapy 2022; 117:47-62. [DOI: 10.1016/j.physio.2022.08.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 04/05/2022] [Accepted: 08/31/2022] [Indexed: 10/14/2022]
|
5
|
Renz M, Müllejans L, Riedel J, Mohnke K, Rissel R, Ziebart A, Duenges B, Hartmann EK, Ruemmler R. High PEEP Levels during CPR Improve Ventilation without Deleterious Haemodynamic Effects in Pigs. J Clin Med 2022; 11:jcm11164921. [PMID: 36013161 PMCID: PMC9410261 DOI: 10.3390/jcm11164921] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 08/17/2022] [Accepted: 08/18/2022] [Indexed: 11/16/2022] Open
Abstract
Background: Invasive ventilation during cardiopulmonary resuscitation (CPR) is very complex due to unique thoracic pressure conditions. Current guidelines do not provide specific recommendations for ventilation during ongoing chest compressions regarding positive end-expiratory pressure (PEEP). This trial examines the cardiopulmonary effects of PEEP application during CPR. Methods: Forty-two German landrace pigs were anaesthetised, instrumented, and randomised into six intervention groups. Three PEEP levels (0, 8, and 16 mbar) were compared in high standard and ultralow tidal volume ventilation. After the induction of ventricular fibrillation, mechanical chest compressions and ventilation were initiated and maintained for thirty minutes. Blood gases, ventilation/perfusion ratio, and electrical impedance tomography loops were taken repeatedly. Ventilation pressures and haemodynamic parameters were measured continuously. Postmortem lung tissue damage was assessed using the diffuse alveolar damage (DAD) score. Statistical analyses were performed using SPSS, and p values <0.05 were considered significant. Results: The driving pressure (Pdrive) showed significantly lower values when using PEEP 16 mbar than when using PEEP 8 mbar (p = 0.045) or PEEP 0 mbar (p < 0.001) when adjusted for the ventilation mode. Substantially increased overall lung damage was detected in the PEEP 0 mbar group (vs. PEEP 8 mbar, p = 0.038; vs. PEEP 16 mbar, p = 0.009). No significant differences in mean arterial pressure could be detected. Conclusion: The use of PEEP during CPR seems beneficial because it optimises ventilation pressures and reduces lung damage without significantly compromising blood pressure. Further studies are needed to examine long-term effects in resuscitated animals.
Collapse
|
6
|
Abstract
OBJECTIVE To describe, through a narrative review, the physiologic principles underlying electrical impedance tomography, and its potential applications in managing acute respiratory distress syndrome (ARDS). To address the current evidence supporting its use in different clinical scenarios along the ARDS management continuum. DATA SOURCES We performed an online search in Pubmed to review articles. We searched MEDLINE, Cochrane Central Register, and clinicaltrials.gov for controlled trials databases. STUDY SELECTION Selected publications included case series, pilot-physiologic studies, observational cohorts, and randomized controlled trials. To describe the rationale underlying physiologic principles, we included experimental studies. DATA EXTRACTION Data from relevant publications were reviewed, analyzed, and its content summarized. DATA SYNTHESIS Electrical impedance tomography is an imaging technique that has aided in understanding the mechanisms underlying multiple interventions used in ARDS management. It has the potential to monitor and predict the response to prone positioning, aid in the dosage of flow rate in high-flow nasal cannula, and guide the titration of positive-end expiratory pressure during invasive mechanical ventilation. The latter has been demonstrated to improve physiologic and mechanical parameters correlating with lung recruitment. Similarly, its use in detecting pneumothorax and harmful patient-ventilator interactions such as pendelluft has been proven effective. Nonetheless, its impact on clinically meaningful outcomes remains to be determined. CONCLUSIONS Electrical impedance tomography is a potential tool for the individualized management of ARDS throughout its different stages. Clinical trials should aim to determine whether a specific approach can improve clinical outcomes in ARDS management.
Collapse
|
7
|
Influence of the end inspiratory pause on respiratory mechanics and tidal gas distribution of surgical patients ventilated under a tailored open lung approach strategy: A randomised, crossover trial. Anaesth Crit Care Pain Med 2022; 41:101038. [DOI: 10.1016/j.accpm.2022.101038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Revised: 12/09/2021] [Accepted: 12/12/2021] [Indexed: 11/21/2022]
|
8
|
Effects of PEEP on the relationship between tidal volume and total impedance change measured via electrical impedance tomography (EIT). J Clin Monit Comput 2022; 36:325-334. [PMID: 33492490 PMCID: PMC7829490 DOI: 10.1007/s10877-021-00651-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Accepted: 01/06/2021] [Indexed: 01/31/2023]
Abstract
Electrical impedance tomography (EIT) is used in lung physiology monitoring. There is evidence that EIT is linearly associated with global tidal volume (VT) in clinically healthy patients where no positive end-expiratory pressure (PEEP) is applied. This linearity has not been challenged by altering lung conditions. The aim of this study was to determine the effect of PEEP on VT estimation, using EIT technology and spirometry, and observe the stability of the relationship under changing lung conditions. Twelve male castrated cattle (Steer), mean age 7.8 months (SD ± 1.7) were premedicated with xylazine followed by anaesthesia induction with ketamine and maintenance with halothane in oxygen via an endotracheal tube. An EIT belt was applied around the thorax at the level of the fifth intercostal space. Volume controlled ventilation was used. PEEP was increased in a stepwise manner from 0 to 5, 10 and 15 cmH2O. At each PEEP, the VT was increased stepwise from 5 to 10 and 15 mL kg-1. After a minute of stabilisation, total impedance change (VTEIT), using EIT and VT measured by a spirometer connected to a flow-partitioning device (VTSpiro) was recorded for the following minute before changing ventilator settings. Data was analysed using linear regression and multi variable analysis. There was a linear relationship between VTEIT and VTSpiro at all levels of PEEP with an R2 of 0.71, 0.68, 0.63 and 0.63 at 0, 5, 10 and 15 cmH2O, respectively. The variance in VTEIT was best described by peak inspiratory pressure (PIP) and PEEP (adjusted R2 0.82) while variance in VTSpiro was best described by PIP and airway deadspace (adjusted R2 0.76). The relationship between VTEIT and VTSpiro remains linear with changes in tidal volume, and stable across altered lung conditions. This may have application for monitoring and assessment in vivo.
Collapse
|
9
|
Alsaker M, Cárdenas DAC, Furuie SS, Mueller JL. Complementary use of priors for pulmonary imaging with electrical impedance and ultrasound computed tomography. JOURNAL OF COMPUTATIONAL AND APPLIED MATHEMATICS 2021; 395:113591. [PMID: 34092904 PMCID: PMC8177074 DOI: 10.1016/j.cam.2021.113591] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
For medical professionals caring for patients undergoing mechanical ventilation due to respiratory failure, the ability to quickly and safely obtain images of pulmonary function at the patient's bedside would be highly desirable. Such images could be used to provide early warnings of developing pulmonary pathologies in real time, thereby reducing the incidence of complications and improving patient outcomes. Electrical impedance tomography (EIT) and low-frequency ultrasound computed tomography (USCT) are two imaging techniques with the potential to provide real-time non-ionizing pulmonary monitoring in the ICU setting, and each method has its own unique advantages as well as drawbacks. In this work, we describe a new algorithm for a system in which the strengths of the two modalities are combined in a complementary fashion. Specifically, preliminary reconstructions from each modality are used as priors to stabilize subsequent reconstructions, providing improved spatial resolution, sharper organ boundaries, and enhanced appearance of pathologies and other features. Results are validated using three numerically simulated thoracic phantoms representing pulmonary pathologies.
Collapse
Affiliation(s)
- Melody Alsaker
- Department of Mathematics; Gonzaga University, Spokane, WA 99258 USA
| | | | | | - Jennifer L. Mueller
- Department of Mathematics and School of Biomedical Engineering, Colorado State University, CO 80523 USA
| |
Collapse
|
10
|
Hovnanian ALD, Costa ELV, Hoette S, Fernandes CJCS, Jardim CVP, Dias BA, Morinaga LTK, Amato MBP, Souza R. Electrical impedance tomography in pulmonary arterial hypertension. PLoS One 2021; 16:e0248214. [PMID: 33730110 PMCID: PMC7968654 DOI: 10.1371/journal.pone.0248214] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2020] [Accepted: 02/22/2021] [Indexed: 02/06/2023] Open
Abstract
The characterization of pulmonary arterial hypertension (PAH) relies mainly on right heart catheterization (RHC). Electrical impedance tomography (EIT) provides a non-invasive estimation of lung perfusion that could complement the hemodynamic information from RHC. To assess the association between impedance variation of lung perfusion (ΔZQ) and hemodynamic profile, severity, and prognosis, suspected of PAH or worsening PAH patients were submitted simultaneously to RHC and EIT. Measurements of ΔZQ were obtained. Based on the results of the RHC, 35 patients composed the PAH group, and eight patients, the normopressoric (NP) group. PAH patients showed a significantly reduced ΔZQ compared to the NP group. There was a significant correlation between ΔZQ and hemodynamic parameters, particularly with stroke volume (SV) (r = 0.76; P < 0.001). At 60 months, 15 patients died (43%) and 1 received lung transplantation; at baseline they had worse hemodynamics, and reduced ΔZQ when compared to survivors. Patients with low ΔZQ (≤154.6%.Kg) presented significantly worse survival (P = 0.033). ΔZQ is associated with hemodynamic status of PAH patients, with disease severity and survival, demonstrating EIT as a promising tool for monitoring patients with pulmonary vascular disease.
Collapse
Affiliation(s)
- André L. D. Hovnanian
- Pulmonary Divison, Heart Institute, Hospital das Clínicas, University of São Paulo, São Paulo, Brazil
- * E-mail:
| | - Eduardo L. V. Costa
- Pulmonary Divison, Heart Institute, Hospital das Clínicas, University of São Paulo, São Paulo, Brazil
| | - Susana Hoette
- Pulmonary Divison, Heart Institute, Hospital das Clínicas, University of São Paulo, São Paulo, Brazil
| | - Caio J. C. S. Fernandes
- Pulmonary Divison, Heart Institute, Hospital das Clínicas, University of São Paulo, São Paulo, Brazil
| | - Carlos V. P. Jardim
- Pulmonary Divison, Heart Institute, Hospital das Clínicas, University of São Paulo, São Paulo, Brazil
| | - Bruno A. Dias
- Pulmonary Divison, Heart Institute, Hospital das Clínicas, University of São Paulo, São Paulo, Brazil
| | - Luciana T. K. Morinaga
- Pulmonary Divison, Heart Institute, Hospital das Clínicas, University of São Paulo, São Paulo, Brazil
| | - Marcelo B. P. Amato
- Pulmonary Divison, Heart Institute, Hospital das Clínicas, University of São Paulo, São Paulo, Brazil
| | - Rogério Souza
- Pulmonary Divison, Heart Institute, Hospital das Clínicas, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
11
|
Hahn G, Niewenhuys J, Just A, Tonetti T, Behnemann T, Rapetti F, Collino F, Vasques F, Maiolo G, Romitti F, Gattinoni L, Quintel M, Moerer O. Monitoring lung impedance changes during long-term ventilator-induced lung injury ventilation using electrical impedance tomography. Physiol Meas 2020; 41:095011. [PMID: 33035199 DOI: 10.1088/1361-6579/abb1fb] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE The target of this methodological evaluation was the feasibility of long-term monitoring of changes in lung conditions by time-difference electrical impedance tomography (tdEIT). In contrast to ventilation monitoring by tdEIT, the monitoring of end-expiratory (EELIC) or end-inspiratory (EILIC) lung impedance change always requires a reference measurement. APPROACH To determine the stability of the used Pulmovista 500® EIT system, as a prerequisite it was initially secured on a resistive phantom for 50 h. By comparing the slopes of EELIC for the whole lung area up to 48 h from 36 pigs ventilated at six positive end-expiratory pressure (PEEP) levels from 0 to 18 cmH2O we found a good agreement (range of r 2 = 0.93-1.0) between absolute EIT (aEIT) and tdEIT values. This justified the usage of tdEIT with its superior local resolution compared to aEIT for long-term determination of EELIC. MAIN RESULTS The EELIC was between -0.07 Ωm day-1 at PEEP 4 and -1.04 Ωm day-1 at PEEP 18 cmH2O. The complex local time pattern for EELIC was roughly quantified by the new parameter, centre of end-expiratory change (CoEEC), in equivalence to the established centre of ventilation (CoV). The ventrally located mean of the CoV was fairly constant in the range of 42%-46% of thorax diameter; however, on the contrary, the CoEEC shifted from about 40% to about 75% in the dorsal direction for PEEP levels of 14 and 18 cmH2O. SIGNIFICANCE The observed shifts started earlier for higher PEEP levels. Changes of EELI could be precisely monitored over a period of 48 h by tdEIT on pigs.
Collapse
Affiliation(s)
- G Hahn
- Department of Anaesthesiology, University Medical Center Göttingen (UMG), Robert-Koch-Str. 40, D-37075, Göttingen, Germany
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Mellenthin MM, Mueller JL, de Camargo EDLB, de Moura FS, Santos TBR, Lima RG, Hamilton SJ, Muller PA, Alsaker M. The ACE1 Electrical Impedance Tomography System for Thoracic Imaging. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT 2019; 68:3137-3150. [PMID: 33223563 PMCID: PMC7678726 DOI: 10.1109/tim.2018.2874127] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
The design and performance of the ACE1 (Active Complex Electrode) electrical impedance tomography system for single-ended phasic voltage measurements is presented. The design of the hardware and calibration procedures allow for reconstruction of conductivity and permittivity images. Phase measurement is achieved with the ACE1 active electrode circuit which measures the amplitude and phase of the voltage and the applied current at the location at which current is injected into the body. An evaluation of the system performance under typical operating conditions includes details of demodulation and calibration and an in-depth look at insightful metrics, such as signal-to-noise ratio variations during a single current pattern. Static and dynamic images of conductivity and permittivity are presented from ACE1 data collected on tank phantoms and human subjects to illustrate the system's utility.
Collapse
Affiliation(s)
| | - Jennifer L Mueller
- Department of Mathematics and School of Biomedical Engineering and the Department of Electrical and Computer Engineering, Colorado State University, CO 80523 USA
| | | | - Fernando Silva de Moura
- Center for Engineering, Modeling and Applied Social Sciences, Federal University of ABC, São Paulo, Brazil
| | | | - Raul Gonzalez Lima
- Mechanical Engineering Department, University of São Paulo, São Paulo, Brazil
| | - Sarah J Hamilton
- Department of Mathematics, Statistics, and Computer Science; Marquette University, Milwaukee, WI, 53233 USA
| | - Peter A Muller
- Department of Mathematics, Colorado State University, CO 80523 USA
| | - Melody Alsaker
- Department of Mathematics, Colorado State University, Fort Collins, C0, 80523 USA
| |
Collapse
|
13
|
Standardized Unloading of Respiratory Muscles during Neurally Adjusted Ventilatory Assist: A Randomized Crossover Pilot Study. Anesthesiology 2019; 129:769-777. [PMID: 30045094 DOI: 10.1097/aln.0000000000002335] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
WHAT WE ALREADY KNOW ABOUT THIS TOPIC WHAT THIS ARTICLE TELLS US THAT IS NEW: BACKGROUND:: Currently, there is no standardized method to set the support level in neurally adjusted ventilatory assist (NAVA). The primary aim was to explore the feasibility of titrating NAVA to specific diaphragm unloading targets, based on the neuroventilatory efficiency (NVE) index. The secondary outcome was to investigate the effect of reduced diaphragm unloading on distribution of lung ventilation. METHODS This is a randomized crossover study between pressure support and NAVA at different diaphragm unloading at a single neurointensive care unit. Ten adult patients who had started weaning from mechanical ventilation completed the study. Two unloading targets were used: 40 and 60%. The NVE index was used to guide the titration of the assist in NAVA. Electrical impedance tomography data, blood-gas samples, and ventilatory parameters were collected. RESULTS The median unloading was 43% (interquartile range 32, 60) for 40% unloading target and 60% (interquartile range 47, 69) for 60% unloading target. NAVA with 40% unloading led to more dorsal ventilation (center of ventilation at 55% [51, 56]) compared with pressure support (52% [49, 56]; P = 0.019). No differences were found in oxygenation, CO2, and respiratory parameters. The electrical activity of the diaphragm was higher during NAVA with 40% unloading than in pressure support. CONCLUSIONS In this pilot study, NAVA could be titrated to different diaphragm unloading levels based on the NVE index. Less unloading was associated with greater diaphragm activity and improved ventilation of the dependent lung regions.
Collapse
|
14
|
Nguyen DM, Qian P, Barry T, McEwan A. Self-weighted NOSER-prior electrical impedance tomography using internal electrodes in cardiac radiofrequency ablation. Physiol Meas 2019; 40:065006. [DOI: 10.1088/1361-6579/ab1937] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
15
|
Rahmel T, Koniusch A, Schwertner M, Oprea G, Adamzik M, Nowak H. Evaluation of inhaled salbutamol effectiveness under supportive use of electrical impedance tomography in ventilated ICU patients: study protocol for a randomised controlled clinical trial. BMJ Open 2019; 9:e026038. [PMID: 30862635 PMCID: PMC6429886 DOI: 10.1136/bmjopen-2018-026038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Revised: 01/25/2019] [Accepted: 01/28/2019] [Indexed: 11/04/2022] Open
Abstract
INTRODUCTION The inhalative administration of drugs is a non-invasive application form that is regularly used in the treatment of ventilated patients in critical care setting. However, assessment of effectiveness or distribution of nebulised drugs is one of the lacking cornerstones of modern intensive care monitoring. Electrical impedance tomography (EIT) may provide a promising new monitoring and guiding tool for an adequate optimisation of mechanical ventilation in critically ill patients. EIT may assist in defining mechanical ventilation settings, assess distribution of tidal volume and evaluate associated pathologies at bedside. This study aims to elucidate the extent to which the effectiveness of inhaled salbutamol can be increased by the additional use of EIT for optimisation of respirator settings. METHODS AND ANALYSIS This study is a randomised, open-label, superiority trial conducted on an intensive care unit of a German university hospital, comparing two groups of mechanically ventilated patients with an acute or chronic bronchial airway obstruction according to the effectiveness of inhaled salbutamol with (intervention) or without (control) additional use of EIT for optimising ventilator settings. The primary outcome is change in airway resistance 30 min after salbutamol inhalation. ETHICS AND DISSEMINATION The study has received approval from the Ethics Committee of the Medical Faculty of Ruhr-University Bochum (17-6306). The results will be made available to critical care survivors, their caregivers, the funders, the critical care societies and other researchers by publication in a peer-reviewed journal. TRIAL REGISTRATION NUMBER DRKS00014706; Pre-results.
Collapse
Affiliation(s)
- Tim Rahmel
- Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Universitätsklinikum Knappschaftskrankenhaus Bochum, Bochum, Germany
| | - Alexandra Koniusch
- Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Universitätsklinikum Knappschaftskrankenhaus Bochum, Bochum, Germany
| | - Martin Schwertner
- Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Universitätsklinikum Knappschaftskrankenhaus Bochum, Bochum, Germany
| | - Günther Oprea
- Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Universitätsklinikum Knappschaftskrankenhaus Bochum, Bochum, Germany
| | - Michael Adamzik
- Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Universitätsklinikum Knappschaftskrankenhaus Bochum, Bochum, Germany
| | - Hartmuth Nowak
- Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Universitätsklinikum Knappschaftskrankenhaus Bochum, Bochum, Germany
| |
Collapse
|
16
|
Muller PA, Mueller JL, Mellenthin M, Murthy R, Capps M, Wagner BD, Alsaker M, Deterding R, Sagel SD, Hoppe J. Evaluation of surrogate measures of pulmonary function derived from electrical impedance tomography data in children with cystic fibrosis. Physiol Meas 2018; 39:045008. [PMID: 29565263 DOI: 10.1088/1361-6579/aab8c4] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Lung function monitoring by spirometry plays a critical role in the clinical care of pediatric cystic fibrosis (CF) patients, but many young children are unable to perform spirometry, and the outputs are often normal even in the presence of lung disease. Measures derived from electrical impedance tomography (EIT) images were studied for their utility as potential surrogates for spirometry in CF patients and to assess response to intravenous antibiotic treatment for acute pulmonary exacerbations (PEx) in a subset of patients. APPROACH EIT data were collected on 35 subjects (21 with CF, 14 healthy controls, 8 CF patients pre- and post-treatment for an acute PEx) ages 2 to 20 years during tidal breathing and also concurrently with spirometry on subjects over age 8. EIT-derived measures of FEV1, FVC, and FEV1/FVC were computed globally and regionally from dynamic EIT images. MAIN RESULTS Global EIT-derived FEV1/FVC showed good correlation with spirometry FEV1/FVC values (r = 0.54, p = 0.01), and were able to distinguish between the groups (p = 0.01). Lung heterogeneity was assessed through the spatial coefficient of variation (CV) of EIT difference images between key time points, and the CVs for EIT-derived FEV1 and FVC showed significant correlation with the CV for tidal breathing (r = 0.47, p = 0.01 and r = 0.50, p = 0.01, respectively). Global EIT-derived FEV1/FVC was better able to distinguish between groups than spirometry FEV1 (F-values 776.5 and 146.3, respectively, p < 0.01.) The same held true for the CVs for EIT-derived FEV1, FVC, and tidal breathing (F-values 215.93, 193.89, 204.57, respectively, p < 0.01). SIGNIFICANCE The strong correlation between the CVs for tidal breathing, FEV1, and FVC, and the statistically significant ability of CV for tidal breathing to distinguish between healthy subjects and CF patients, and between the studied CF disease states suggests that the CV may be useful for measuring the extent and severity of structural lung disease.
Collapse
Affiliation(s)
- Peter A Muller
- Department of Mathematics & Statistics, Villanova University, PA, United States of America. was at Department of Mathematics, Colorado State University, CO, United States of America
| | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Caruana LR, Barnett AG, Tronstad O, Paratz JD, Chang AT, Fraser JF. Global tidal variations, regional distribution of ventilation, and the regional onset of filling determined by electrical impedance tomography: reproducibility. Anaesth Intensive Care 2017; 45:235-243. [PMID: 28267946 DOI: 10.1177/0310057x1704500214] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The reproducibility of the regional distribution of ventilation and the timing of onset of regional filling as measured by electrical impedance tomography lacks evidence. This study investigated whether electrical impedance tomography measurements in healthy males were reproducible when electrodes were replaced between measurements. Part 1: Recordings of five volunteers lying supine were made using electrical impedance tomography and a pneumotachometer. Measurements were repeated at least three hours later. Skin marking ensured accurate replacement of electrodes. No stabilisation period was allowed. Part 2: Electrical impedance tomography recordings of ten volunteers; a 15 minute stabilisation period, extra skin markings, and time-averaging were incorporated to improve the reproducibility. Reproducibility was determined using the Bland-Altman method. To judge the transferability of the limits of agreement, a Pearson correlation was used for electrical impedance tomography tidal variation and tidal volume. Tidal variation was judged to be reproducible due to the significant correlation between tidal variation and tidal volume (r2 = 0.93). The ventilation distribution was not reproducible. A stabilisation period, extra skin markings and time-averaging did not improve the outcome. The timing of regional onset of filling was reproducible and could prove clinically valuable. The reproducibility of the tidal variation indicates that non-reproducibility of the ventilation distribution was probably a biological difference and not measurement error. Other causes of variability such as electrode placement variability or lack of stabilisation when accounted for did not improve the reproducibility of the ventilation distribution.
Collapse
Affiliation(s)
- L R Caruana
- Physiotherapist, The Critical Care Research Group, The Prince Charles Hospital, The University of Queensland School of Medicine, Brisbane, Queensland
| | - A G Barnett
- Associate Professor, The Critical Care Research Group, The Prince Charles Hospital, School of Public Health & Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Queensland
| | - O Tronstad
- Clinical Lead Physiotherapist, The Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland
| | - J D Paratz
- Physiotherapist, The Critical Care Research Group, The Prince Charles Hospital, Burns, Trauma and Critical Research Centre, School of Medicine, University of Queensland, Brisbane, Griffith University, Southport, Queensland
| | - A T Chang
- Physiotherapist, The Critical Care Research Group, The Prince Charles Hospital, School of Health and Rehabilitation Sciences, University of Queensland, Brisbane, Queensland
| | - J F Fraser
- Director, The Critical Care Research Group, The Prince Charles Hospital, Professor, School of Health and Rehabilitation Sciences, University of Queensland, Brisbane, Queensland
| |
Collapse
|
18
|
Prone Positioning Improves Ventilation Homogeneity in Children With Acute Respiratory Distress Syndrome. Pediatr Crit Care Med 2017; 18:e229-e234. [PMID: 28328787 DOI: 10.1097/pcc.0000000000001145] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES To determine the effect of prone positioning on ventilation distribution in children with acute respiratory distress syndrome. DESIGN Prospective observational study. SETTING Paediatric Intensive Care at Red Cross War Memorial Children's Hospital, Cape Town, South Africa. PATIENTS Mechanically ventilated children with acute respiratory distress syndrome. INTERVENTIONS Electrical impedance tomography measures were taken in the supine position, after which the child was turned into the prone position, and subsequent electrical impedance tomography measurements were taken. MEASUREMENTS AND MAIN RESULTS Thoracic electrical impedance tomography measures were taken at baseline and after 5, 20, and 60 minutes in the prone position. The proportion of ventilation, regional filling characteristics, and global inhomogeneity index were calculated for the ventral and dorsal lung regions. Arterial blood gas measurements were taken before and after the intervention. A responder was defined as having an improvement of more than 10% in the oxygenation index after 60 minutes in prone position. Twelve children (nine male, 65%) were studied. Four children were responders, three were nonresponders, and five showed no change to prone positioning. Ventilation in ventral and dorsal lung regions was no different in the supine or prone positions between response groups. The proportion of ventilation in the dorsal lung increased from 49% to 57% in responders, while it became more equal between ventral and dorsal lung regions in the prone position in nonresponders. Responders showed greater improvements in ventilation homogeneity with R improving from 0.86 ± 0.24 to 0.98 ± 0.02 in the ventral lung and 0.91 ± 0.15 to 0.99 ± 0.01 in the dorsal lung region with time in the prone position. CONCLUSIONS The response to prone position was variable in children with acute respiratory distress syndrome. Prone positioning improves homogeneity of ventilation and may result in recruitment of the dorsal lung regions.
Collapse
|
19
|
Traser L, Knab J, Echternach M, Fuhrer H, Richter B, Buerkle H, Schumann S. Regional ventilation during phonation in professional male and female singers. Respir Physiol Neurobiol 2017; 239:26-33. [PMID: 28109943 DOI: 10.1016/j.resp.2017.01.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2016] [Revised: 01/05/2017] [Accepted: 01/11/2017] [Indexed: 01/08/2023]
Abstract
The respiratory system is a central part of voice production, but details in breath control during phonation are not yet fully understood. This study therefore aims to investigate regional ventilation of the lungs during phonation. It was analyzed in 11 professional singers using electrical impedance tomography during breathing and phonation with maximum phonation time. Our results show differences in impedance changes between phonation and exhalation in the courses of time and amplitude normalized curves. Furthermore, differences related to gender and professionalism were found in the temporal and spatial profiles of regional ventilation. For female singers (sopranos and mezzo-sopranos) the anterior region participated less at the start of ventilation, and was more stable at the midpoint compared to male singers (tenors). This might be an expression of a smaller relative movement in rib cage and anterior diaphragm, primarily in early phonation.
Collapse
Affiliation(s)
- Louisa Traser
- Institute of Musicians' Medicine, Medical Center-University of Freiburg, Germany; Department of Otolaryngology, Medical Center-University of Freiburg, Germany; Faculty of Medicine, University of Freiburg, Germany.
| | - Jana Knab
- Faculty of Medicine, University of Freiburg, Germany; Department of Anesthesiology and Critical Care, Medical Center-University of Freiburg, Germany
| | - Matthias Echternach
- Institute of Musicians' Medicine, Medical Center-University of Freiburg, Germany; Faculty of Medicine, University of Freiburg, Germany
| | - Hannah Fuhrer
- Faculty of Medicine, University of Freiburg, Germany; Department of Neurology, Medical Center-University of Freiburg, Germany
| | - Bernhard Richter
- Institute of Musicians' Medicine, Medical Center-University of Freiburg, Germany; Faculty of Medicine, University of Freiburg, Germany
| | - Hartmut Buerkle
- Faculty of Medicine, University of Freiburg, Germany; Department of Anesthesiology and Critical Care, Medical Center-University of Freiburg, Germany
| | - Stefan Schumann
- Faculty of Medicine, University of Freiburg, Germany; Department of Anesthesiology and Critical Care, Medical Center-University of Freiburg, Germany
| |
Collapse
|
20
|
Effect of time and body position on ventilation in premature infants. Pediatr Res 2016; 80:499-504. [PMID: 27331352 DOI: 10.1038/pr.2016.116] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2016] [Accepted: 04/05/2016] [Indexed: 11/08/2022]
Abstract
BACKGROUND Infants with respiratory dysfunction undergo regular position changes to improve lung function however it is not known how often a position change should occur. This study measured changes in lung function occurring over time after repositioning in preterm infants. METHODS Changes in end-expiratory level (EEL) and ventilation distribution were measured 30 mins, 2 h, and 4 h after repositioning into either prone, quarter turn from prone, or supine using Electrical Impedance Tomography (EIT). Physiological measurements were also taken. RESULTS Sixty preterm infants were included in the study. Infants receiving respiratory support (mechanical ventilation or continuous positive airway pressure (CPAP)) had improved ventilation homogeneity after 2 h (P < 0.01), maintained at 4 h. Spontaneously breathing infants had improved homogeneity at 2 h (P < 0.01) and improved global EEL after 4 h (P < 0.01) whereas infants receiving CPAP demonstrated an improved global EEL at 2 h (P < 0.01). CONCLUSION Regional ventilation distribution is influenced by time independent of changes due to body position. Differences exist between infants on ventilatory support compared with those who are spontaneously breathing. Infants receiving ventilatory support have a physiological peak in lung function after 2 h which remains above baseline at 4 h. A change in body position facilitates an improvement in lung function in infants on ventilatory support.
Collapse
|
21
|
Yerworth RJ, Frerichs I, Bayford R. Analysis and compensation for errors in electrical impedance tomography images and ventilation-related measures due to serial data collection. J Clin Monit Comput 2016; 31:1093-1101. [PMID: 27534624 PMCID: PMC5599443 DOI: 10.1007/s10877-016-9920-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2015] [Accepted: 08/09/2016] [Indexed: 12/27/2022]
Abstract
Electrical impedance tomography (EIT) is increasingly being used as a bedside tool for monitoring regional lung ventilation. However, most clinical systems use serial data collection which, if uncorrected, results in image distortion, particularly at high breathing rates. The objective of this study was to determine the extent to which this affects derived parameters. Raw EIT data were acquired with the GOE-MF II EIT device (CareFusion, Höchberg, Germany) at a scan rate of 13 images/s during both spontaneous breathing and mechanical ventilation. Boundary data for periods of undisturbed tidal breathing were corrected for serial data collection errors using a Fourier based algorithm. Images were reconstructed for both the corrected and original data using the GREIT algorithm, and parameters describing the filling characteristics of the right and left lung derived on a breath by breath basis. Values from the original and corrected data were compared using paired t-tests. Of the 33 data sets, 23 showed significant differences in filling index for at least one region, 11 had significant differences in calculated tidal impedance change and 12 had significantly different filling fractions (p = 0.05). We conclude that serial collection errors should be corrected before image reconstruction to avoid clinically misleading results.
Collapse
Affiliation(s)
- Rebecca J Yerworth
- Medical Physics and Biomedical Engineering Department, University College London, London, WC1E 6BT, England, UK.
| | - Inéz Frerichs
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Richard Bayford
- Department of Natural Sciences, Middlesex University, London, England, UK
| |
Collapse
|
22
|
Vogt B, Zhao Z, Zabel P, Weiler N, Frerichs I. Regional lung response to bronchodilator reversibility testing determined by electrical impedance tomography in chronic obstructive pulmonary disease. Am J Physiol Lung Cell Mol Physiol 2016; 311:L8-L19. [DOI: 10.1152/ajplung.00463.2015] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2016] [Accepted: 05/17/2016] [Indexed: 01/01/2023] Open
Abstract
Patients with obstructive lung diseases commonly undergo bronchodilator reversibility testing during examination of their pulmonary function by spirometry. A positive response is defined by an increase in forced expiratory volume in 1 s (FEV1). FEV1 is a rather nonspecific criterion not allowing the regional effects of bronchodilator to be assessed. We employed the imaging technique of electrical impedance tomography (EIT) to visualize the spatial and temporal ventilation distribution in 35 patients with chronic obstructive pulmonary disease at baseline and 5, 10, and 20 min after bronchodilator inhalation. EIT scanning was performed during tidal breathing and forced full expiration maneuver in parallel with spirometry. Ventilation distribution was determined by EIT by calculating the image pixel values of FEV1, forced vital capacity (FVC), tidal volume, peak flow, and mean forced expiratory flow between 25 and 75% of FVC. The global inhomogeneity indexes of each measure and histograms of pixel FEV1/FVC values were then determined to assess the bronchodilator effect on spatial ventilation distribution. Temporal ventilation distribution was analyzed from pixel values of times needed to exhale 75 and 90% of pixel FVC. Based on spirometric FEV1, significant bronchodilator response was found in 17 patients. These patients exhibited higher postbronchodilator values of all regional EIT-derived lung function measures in contrast to nonresponders. Ventilation distribution was inhomogeneous in both groups. Significant improvements were noted for spatial distribution of pixel FEV1 and tidal volume and temporal distribution in responders. By providing regional data, EIT might increase the diagnostic and prognostic information derived from reversibility testing.
Collapse
Affiliation(s)
- Barbara Vogt
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Zhanqi Zhao
- Department of Biomedical Engineering, Furtwangen University, Villingen-Schwenningen, Germany; and
| | - Peter Zabel
- Department of Pneumology, Medical Clinic, Research Center Borstel, Germany
| | - Norbert Weiler
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Inéz Frerichs
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| |
Collapse
|
23
|
Boverman G, Isaacson D, Newell JC, Saulnier GJ, Kao TJ, Amm BC, Wang X, Davenport DM, Chong DH, Sahni R, Ashe JM. Efficient Simultaneous Reconstruction of Time-Varying Images and Electrode Contact Impedances in Electrical Impedance Tomography. IEEE Trans Biomed Eng 2016; 64:795-806. [PMID: 27295649 DOI: 10.1109/tbme.2016.2578646] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE In electrical impedance tomography (EIT), we apply patterns of currents on a set of electrodes at the external boundary of an object, measure the resulting potentials at the electrodes, and, given the aggregate dataset, reconstruct the complex conductivity and permittivity within the object. It is possible to maximize sensitivity to internal conductivity changes by simultaneously applying currents and measuring potentials on all electrodes but this approach also maximizes sensitivity to changes in impedance at the interface. METHODS We have, therefore, developed algorithms to assess contact impedance changes at the interface as well as to efficiently and simultaneously reconstruct internal conductivity/permittivity changes within the body. We use simple linear algebraic manipulations, the generalized singular value decomposition, and a dual-mesh finite-element-based framework to reconstruct images in real time. We are also able to efficiently compute the linearized reconstruction for a wide range of regularization parameters and to compute both the generalized cross-validation parameter as well as the L-curve, objective approaches to determining the optimal regularization parameter, in a similarly efficient manner. RESULTS Results are shown using data from a normal subject and from a clinical intensive care unit patient, both acquired with the GE GENESIS prototype EIT system, demonstrating significantly reduced boundary artifacts due to electrode drift and motion artifact.
Collapse
|
24
|
Radke OC, Schneider T, Vogel E, Koch T. Effect of Trigger Sensitivity on Redistribution of Ventilation During Pressure Support Ventilation Detected by Electrical Impedance Tomography. Anesth Pain Med 2015; 5:e27439. [PMID: 26478865 PMCID: PMC4604485 DOI: 10.5812/aapm.27439v2] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2015] [Revised: 03/15/2015] [Accepted: 03/30/2015] [Indexed: 11/16/2022] Open
Abstract
Background: In supine position, pressure support ventilation causes a redistribution of ventilation towards the ventral regions of the lung. Theoretically, a less sensitive support trigger would cause the patient to breathe more actively, potentially attenuating the effect of positive pressure ventilation. Objectives: To quantify the effect of trigger setting, we assessed redistribution of ventilation during pressure support ventilation (PSV) using electrical impedance tomography (EIT). Patients and Methods: With approval from the local ethics committee, six orthopedic patients were enrolled. All patients had general anesthesia with a laryngeal mask airway and a standardized anesthetic regimen (sufentanil, propofol and sevoflurane). Pressure support trigger settings varied between 2 and 15 L/minute and compared to unassisted spontaneous breathing. From EIT data, the center of ventilation (COV), the fraction of the total ventilation per region of interest (ROI) and intratidal gas distribution were calculated. Results: At all trigger settings, pressure support ventilation caused a significant ventral shift of the center of ventilation compared with during spontaneous breathing, confirmed by the analysis by regions of interest. During spontaneous breathing, COV was not different from baseline values obtained before induction of anesthesia. During PSV, the intratidal regional gas distribution (ITV-analysis) revealed subtle changes during the early inspiratory phase not detected by the COV-analysis. Conclusions: Pressure support ventilation, but not spontaneous breathing, induces a significant redistribution of ventilation towards the ventral region. The sensitivity of the support trigger appears to influence the distribution of ventilation only during the early phase of inspiration.
Collapse
Affiliation(s)
- Oliver C. Radke
- Department of Anesthesiology and Intensive Care Medicine,Klinikum Bremerhaven-Reinkenheide, Postbrookstr. 103, 27574 Bremerhaven, Germany
- Department of Anesthesia and Perioperative Care, San Francisco General Hospital, University of California San Francisco, San Francisco, California, USA
- Department of Anaesthesiology and Intensive Care Medicine, University Hospital, Technische Universitat Dresden, Germany
- Corresponding author: Oliver C. Radke, Department of Anesthesiology and Intensive Care Medicine, Klinikum Bremerhaven-Reinkenheide, Postbrookstr. 103, 27574 Bremerhaven, Germany. Tel: +49-471 2993268, Fax: +49-4712993286, E-mail:
| | - Thomas Schneider
- Department of Anaesthesiology and Intensive Care Medicine, University Hospital, Technische Universitat Dresden, Germany
| | - Elisabeth Vogel
- Department of Anaesthesiology and Intensive Care Medicine, University Hospital, Technische Universitat Dresden, Germany
| | - Thea Koch
- Department of Anaesthesiology and Intensive Care Medicine, University Hospital, Technische Universitat Dresden, Germany
| |
Collapse
|
25
|
Lupton-Smith A, Argent A, Rimensberger P, Morrow B. The effects of prone and supine positions on the regional distribution of ventilation in infants and children using electrical impedance tomography. SOUTH AFRICAN JOURNAL OF PHYSIOTHERAPY 2015; 71:237. [PMID: 30135874 PMCID: PMC6093132 DOI: 10.4102/sajp.v71i1.237] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2015] [Accepted: 04/14/2015] [Indexed: 11/17/2022] Open
Abstract
Background Positioning of ill children is often used to optimise ventilation–perfusion matching, thereby improving oxygenation. Objectives To determine the effects of supine and prone positions, and different head positions, on the distribution of ventilation in healthy, spontaneously breathing infants and children between the ages of 6 months and 9 years. Methods Electrical impedance tomography measurements were recorded from participants in supine and prone positions. Head positions included the head turned to the left and right in supine and prone positions, and in the midline in the supine position. Distribution of ventilation was described using end-expiratory–end-inspiratory relative impedance change. Results A total of 56 participants (boys = 31 [55%]; girls = 25 [45%]) were studied. The dorsal lung was significantly better ventilated than the ventral lung (P < 0.001) in both body positions. The majority of participants (83%) had greater ventilation in the dorsal lung in both positions, whilst five participants (10%) demonstrated consistently better ventilation in the non-dependent lung in both positions. Head position had no effect on the distribution of ventilation. Conclusions This study demonstrates that the distribution of ventilation in healthy, spontaneously breathing infants and children in supine and prone positions is not as straightforward as previously thought, with no clear reversal of the adult pattern evident.
Collapse
Affiliation(s)
- Alison Lupton-Smith
- School of Child and Adolescent Health, University of Cape Town, South Africa
| | - Andrew Argent
- School of Child and Adolescent Health, University of Cape Town, South Africa.,Paediatric Intensive Care Unit, Red Cross War Memorial Children's Hospital, South Africa
| | - Peter Rimensberger
- Paediatric and Neonatal Intensive Care Unit, University Hospital of Geneva, Switzerland
| | - Brenda Morrow
- School of Child and Adolescent Health, University of Cape Town, South Africa.,Paediatric Intensive Care Unit, Red Cross War Memorial Children's Hospital, South Africa
| |
Collapse
|
26
|
REINIUS H, BORGES JB, FREDÉN F, JIDEUS L, CAMARGO EDLB, AMATO MBP, HEDENSTIERNA G, LARSSON A, LENNMYR F. Real-time ventilation and perfusion distributions by electrical impedance tomography during one-lung ventilation with capnothorax. Acta Anaesthesiol Scand 2015; 59:354-68. [PMID: 25556329 DOI: 10.1111/aas.12455] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2014] [Accepted: 11/17/2014] [Indexed: 01/18/2023]
Abstract
BACKGROUND Carbon dioxide insufflation into the pleural cavity, capnothorax, with one-lung ventilation (OLV) may entail respiratory and hemodynamic impairments. We investigated the online physiological effects of OLV/capnothorax by electrical impedance tomography (EIT) in a porcine model mimicking the clinical setting. METHODS Five anesthetized, muscle-relaxed piglets were subjected to first right and then left capnothorax with an intra-pleural pressure of 19 cm H2 O. The contra-lateral lung was mechanically ventilated with a double-lumen tube at positive end-expiratory pressure 5 and subsequently 10 cm H2 O. Regional lung perfusion and ventilation were assessed by EIT. Hemodynamics, cerebral tissue oxygenation and lung gas exchange were also measured. RESULTS During right-sided capnothorax, mixed venous oxygen saturation (P = 0.018), as well as a tissue oxygenation index (P = 0.038) decreased. There was also an increase in central venous pressure (P = 0.006), and a decrease in mean arterial pressure (P = 0.045) and cardiac output (P = 0.017). During the left-sided capnothorax, the hemodynamic impairment was less than during the right side. EIT revealed that during the first period of OLV/capnothorax, no or very minor ventilation on the right side could be seen (3 ± 3% vs. 97 ± 3%, right vs. left, P = 0.007), perfusion decreased in the non-ventilated and increased in the ventilated lung (18 ± 2% vs. 82 ± 2%, right vs. left, P = 0.03). During the second OLV/capnothorax period, a similar distribution of perfusion was seen in the animals with successful separation (84 ± 4% vs. 16 ± 4%, right vs. left). CONCLUSION EIT detected in real-time dynamic changes in pulmonary ventilation and perfusion distributions. OLV to the left lung with right-sided capnothorax caused a decrease in cardiac output, arterial oxygenation and mixed venous saturation.
Collapse
Affiliation(s)
- H. REINIUS
- Hedenstierna Laboratory; Department of Surgical Sciences; Section of Anaesthesiology & Critical Care; Uppsala University; Uppsala Sweden
| | - J. B. BORGES
- Hedenstierna Laboratory; Department of Surgical Sciences; Section of Anaesthesiology & Critical Care; Uppsala University; Uppsala Sweden
- Cardio-Pulmonary Department; Pulmonary Division; Heart Institute (Incor); University of São Paulo; São Paulo Brazil
| | - F. FREDÉN
- Hedenstierna Laboratory; Department of Surgical Sciences; Section of Anaesthesiology & Critical Care; Uppsala University; Uppsala Sweden
| | - L. JIDEUS
- Department of Surgical Sciences; Section of Cardiothoracic Surgery; Uppsala University; Uppsala Sweden
| | - E. D. L. B. CAMARGO
- Department of Mechanical Engineer; Polytechnic School; University of São Paulo; São Paulo Brazil
| | - M. B. P. AMATO
- Cardio-Pulmonary Department; Pulmonary Division; Heart Institute (Incor); University of São Paulo; São Paulo Brazil
| | - G. HEDENSTIERNA
- Hedenstierna Laboratory; Department of Medical Sciences; Clinical Physiology; Uppsala University; Uppsala Sweden
| | - A. LARSSON
- Hedenstierna Laboratory; Department of Surgical Sciences; Section of Anaesthesiology & Critical Care; Uppsala University; Uppsala Sweden
| | - F. LENNMYR
- Department of Surgical Sciences; Section of Cardiothoracic Anesthesiology and Intensive Care; Uppsala University; Uppsala Sweden
| |
Collapse
|
27
|
Influence of Inspiration to Expiration Ratio on Cyclic Recruitment and Derecruitment of Atelectasis in a Saline Lavage Model of Acute Respiratory Distress Syndrome*. Crit Care Med 2015; 43:e65-74. [DOI: 10.1097/ccm.0000000000000788] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|
28
|
Hough JL, Shearman AD, Liley H, Grant CA, Schibler A. Lung recruitment and endotracheal suction in ventilated preterm infants measured with electrical impedance tomography. J Paediatr Child Health 2014; 50:884-9. [PMID: 24965750 DOI: 10.1111/jpc.12661] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 05/09/2014] [Indexed: 11/30/2022]
Abstract
AIMS Although suctioning is a standard airway maintenance procedure, there are significant associated risks, such as loss of lung volume due to high negative suction pressures. This study aims to assess the extent and duration of change in end-expiratory level (EEL) resulting from endotracheal tube (ETT) suction and to examine the relationship between EEL and regional lung ventilation in ventilated preterm infants with respiratory distress syndrome. METHODS A prospective observational clinical study of the effect of ETT suction on 20 non-muscle-relaxed preterm infants with respiratory distress syndrome (RDS) on conventional mechanical ventilation was conducted in a neonatal intensive care unit. Ventilation distribution was measured with regional impedance amplitudes and EEL using electrical impedance tomography. RESULTS ETT suction resulted in a significant increase in EEL post-suction (P < 0.01). Regionally, anterior EEL decreased and posterior EEL increased post-suction, suggesting heterogeneity. Tidal volume was significantly lower in volume-guarantee ventilation compared with pressure-controlled ventilation (P = 0.04). CONCLUSIONS ETT suction in non-muscle-relaxed and ventilated preterm infants with RDS results in significant lung volume increase that is maintained for at least 90 min. Regional differences in distribution of ventilation with ETT suction suggest that the behaviour of the lung is heterogeneous in nature.
Collapse
Affiliation(s)
- Judith L Hough
- Critical Care of the Newborn Program, Mater Research, Brisbane, Queensland, Australia; School of Physiotherapy, Australian Catholic University, Brisbane, Queensland, Australia; Paediatric Critical Care Research Group, Paediatric Intensive Care Unit, Mater Children's Hospital, Brisbane, Queensland, Australia
| | | | | | | | | |
Collapse
|
29
|
Dodd M, Mueller JL. A Real-time D-bar Algorithm for 2-D Electrical Impedance Tomography Data. INVERSE PROBLEMS AND IMAGING (SPRINGFIELD, MO.) 2014; 8:1013-1031. [PMID: 25937856 PMCID: PMC4414053 DOI: 10.3934/ipi.2014.8.1013] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The aim of this paper is to show the feasibility of the D-bar method for real-time 2-D EIT reconstructions. A fast implementation of the D-bar method for reconstructing conductivity changes on a 2-D chest-shaped domain is described. Cross-sectional difference images from the chest of a healthy human subject are presented, demonstrating what can be achieved in real time. The images constitute the first D-bar images from EIT data on a human subject collected on a pairwise current injection system.
Collapse
Affiliation(s)
- Melody Dodd
- Department of Mathematics, Colorado State University, USA
| | - Jennifer L Mueller
- Department of Mathematics and School of Biomedical Engineering, Colorado State University, USA
| |
Collapse
|
30
|
Borges JB, Hedenstierna G, Bergman JS, Amato MBP, Avenel J, Montmerle-Borgdorff S. First-time imaging of effects of inspired oxygen concentration on regional lung volumes and breathing pattern during hypergravity. Eur J Appl Physiol 2014; 115:353-63. [PMID: 25323531 DOI: 10.1007/s00421-014-3020-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2014] [Accepted: 10/02/2014] [Indexed: 11/30/2022]
Abstract
PURPOSE Aeroatelectasis can develop in aircrew flying the latest generation high-performance aircraft. Causes alleged are relative hyperoxia, increased gravity in the head-to-foot direction (+Gz), and compression of legs and stomach by anti-G trousers (AGT). We aimed to assess, in real time, the effects of hyperoxia, +Gz accelerations and AGT inflation on changes in regional lung volumes and breathing pattern evaluated in an axial plane by electrical impedance tomography (EIT). METHODS The protocol mimicked a routine peacetime flight in combat aircraft. Eight subjects wearing AGT were studied in a human centrifuge during 1 h 15 min exposure of +1 to +3.5Gz. They performed this sequence three times, breathing AIR, 44.5 % O2 or 100 % O2. Continuous recording of functional EIT enabled uninterrupted assessment of regional lung volumes at the 5th intercostal level. Breathing pattern was also monitored. RESULTS EIT data showed that +3.5Gz, compared with any moment without hypergravity, caused an abrupt decrease in regional tidal volume (VT) and regional end-expiratory lung volume (EELV) measured in the EIT slice, independently of inspired oxygen concentration. Breathing AIR or 44.5 % O2, sub-regional EELV measured in the EIT slice decreased similarly in dorsal and ventral regions, but sub-regional VT measured in the EIT slice decreased significantly more dorsally than ventrally. Breathing 100 % O2, EELV and VT decreased similarly in both regions. Inspired tidal volume increased in hyperoxia, whereas breathing frequency increased in hypergravity and hyperoxia. CONCLUSIONS Our findings suggest that hypergravity and AGT inflation cause airway closure and air trapping in gravity-dependent lung regions, facilitating absorption atelectasis formation, in particular during hyperoxia.
Collapse
Affiliation(s)
- João Batista Borges
- Hedenstierna Laboratory, Department of Surgical Sciences, Section of Anaesthesiology & Critical Care, Uppsala University, Uppsala, Sweden,
| | | | | | | | | | | |
Collapse
|
31
|
Lupton-Smith AR, Argent AC, Rimensberger PC, Morrow BM. Challenging a paradigm: positional changes in ventilation distribution are highly variable in healthy infants and children. Pediatr Pulmonol 2014; 49:764-71. [PMID: 24009188 DOI: 10.1002/ppul.22893] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2013] [Revised: 07/17/2013] [Accepted: 07/17/2013] [Indexed: 11/06/2022]
Abstract
RATIONALE Current understanding is that infants and children preferentially ventilate non-dependent lungs, a reversal of that of adults, based on studies using krypton-81m ventilation scanning. Participants in these studies had lung disease and were either sedated or ventilated. There is little understanding of the distribution of ventilation in spontaneous breathing healthy infants and children. OBJECTIVES This study aimed to determine the effects of side lying on the distribution of ventilation in healthy, spontaneously breathing infants and children between the ages of 6 months and 9 years. METHODS AND MEASUREMENTS Measurements were taken using electrical impedance tomography (EIT) in supine, left and right side lying. Distribution of ventilation was described using end-expiratory to end-inspiratory relative impedance change. RESULTS Fifty-six (31, 55% male) participants were studied. Nineteen (35%) participants consistently showed greater ventilation in the non-dependent lung, eight (15%) consistently showed greater ventilation in the dependent lung and 28 (51%) showed a varied pattern between left and right side lying. Overall, left side lying resulted in significantly better mean ventilation of the right (non-dependent) lung (P < 0.01). Distribution of ventilation in right side lying was relatively equal between left and right lungs. CONCLUSIONS This study demonstrates that the distribution of ventilation in spontaneously breathing infants and children is not as straightforward as previously described. The distribution of ventilation was variably affected by body position with no clear reversal of the adult pattern evident.
Collapse
Affiliation(s)
- Alison R Lupton-Smith
- School of Child and Adolescent Health, University of Cape Town, Cape Town, South Africa
| | | | | | | |
Collapse
|
32
|
Lung reaeration and reventilation after aspiration of pleural effusions: a study using electrical impedance tomography. Ann Am Thorac Soc 2014; 11:466. [PMID: 24673704 DOI: 10.1513/annalsats.201312-457le] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
33
|
Lung Reaeration and Reventilation after Aspiration of Pleural Effusions. A Study Using Electrical Impedance Tomography. Ann Am Thorac Soc 2014; 11:186-91. [DOI: 10.1513/annalsats.201306-142oc] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
34
|
Caruana LR, Paratz J, Chang AT, Fraser JF. Electrical impedance tomography in the clinical assessment of lung volumes following recruitment manoeuvres. PHYSICAL THERAPY REVIEWS 2013. [DOI: 10.1179/1743288x10y.0000000021] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
35
|
Elke G, Fuld MK, Halaweish AF, Grychtol B, Weiler N, Hoffman EA, Frerichs I. Quantification of ventilation distribution in regional lung injury by electrical impedance tomography and xenon computed tomography. Physiol Meas 2013; 34:1303-18. [DOI: 10.1088/0967-3334/34/10/1303] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
36
|
Effect of PEEP and tidal volume on ventilation distribution and end-expiratory lung volume: a prospective experimental animal and pilot clinical study. PLoS One 2013; 8:e72675. [PMID: 23991138 PMCID: PMC3750001 DOI: 10.1371/journal.pone.0072675] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2012] [Accepted: 07/18/2013] [Indexed: 11/19/2022] Open
Abstract
Introduction Lung-protective ventilation aims at using low tidal volumes (VT) at optimum positive end-expiratory pressures (PEEP). Optimum PEEP should recruit atelectatic lung regions and avoid tidal recruitment and end-inspiratory overinflation. We examined the effect of VT and PEEP on ventilation distribution, regional respiratory system compliance (CRS), and end-expiratory lung volume (EELV) in an animal model of acute lung injury (ALI) and patients with ARDS by using electrical impedance tomography (EIT) with the aim to assess tidal recruitment and overinflation. Methods EIT examinations were performed in 10 anaesthetized pigs with normal lungs ventilated at 5 and 10 ml/kg body weight VT and 5 cmH2O PEEP. After ALI induction, 10 ml/kg VT and 10 cmH2O PEEP were applied. Afterwards, PEEP was set according to the pressure-volume curve. Animals were randomized to either low or high VT ventilation changed after 30 minutes in a crossover design. Ventilation distribution, regional CRS and changes in EELV were analyzed. The same measures were determined in five ARDS patients examined during low and high VT ventilation (6 and 10 (8) ml/kg) at three PEEP levels. Results In healthy animals, high compared to low VT increased CRS and ventilation in dependent lung regions implying tidal recruitment. ALI reduced CRS and EELV in all regions without changing ventilation distribution. Pressure-volume curve-derived PEEP of 21±4 cmH2O (mean±SD) resulted in comparable increase in CRS in dependent and decrease in non-dependent regions at both VT. This implied that tidal recruitment was avoided but end-inspiratory overinflation was present irrespective of VT. In patients, regional CRS differences between low and high VT revealed high degree of tidal recruitment and low overinflation at 3±1 cmH2O PEEP. Tidal recruitment decreased at 10±1 cmH2O and was further reduced at 15±2 cmH2O PEEP. Conclusions Tidal recruitment and end-inspiratory overinflation can be assessed by EIT-based analysis of regional CRS.
Collapse
|
37
|
Hamilton SJ, Mueller JL. Direct EIT reconstructions of complex admittivities on a chest-shaped domain in 2-D. IEEE TRANSACTIONS ON MEDICAL IMAGING 2013; 32:757-769. [PMID: 23314771 DOI: 10.1109/tmi.2012.2237389] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Electrical impedance tomography (EIT) is a medical imaging technique in which current is applied on electrodes on the surface of the body, the resulting voltage is measured, and an inverse problem is solved to recover the conductivity and/or permittivity in the interior. Images are then formed from the reconstructed conductivity and permittivity distributions. In the 2-D geometry, EIT is clinically useful for chest imaging. In this work, an implementation of a D-bar method for complex admittivities on a general 2-D domain is presented. In particular, reconstructions are computed on a chest-shaped domain for several realistic phantoms including a simulated pneumothorax, hyperinflation, and pleural effusion. The method demonstrates robustness in the presence of noise. Reconstructions from trigonometric and pairwise current injection patterns are included.
Collapse
Affiliation(s)
- Sarah J Hamilton
- Department of Mathematics, Colorado State University, Fort Collins, CO 80523, USA.
| | | |
Collapse
|
38
|
Hough JL, Johnston L, Brauer S, Woodgate P, Schibler A. Effect of body position on ventilation distribution in ventilated preterm infants. Pediatr Crit Care Med 2013; 14:171-7. [PMID: 23314179 DOI: 10.1097/pcc.0b013e31826e708a] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
RATIONALE Positioning is considered vital to the maintenance of good lung ventilation by optimizing oxygen transport and gas exchange in ventilated premature infants. Previous studies suggest that the prone position is advantageous; however, no data exist on regional ventilation distribution for this age group. OBJECTIVES To investigate the effect of body position on regional ventilation distribution in ventilated and nonventilated preterm infants using electrical impedance tomography. DESIGN Randomized crossover study design. SETTING Neonatal ICU. PATIENTS A total of 24 ventilated preterm infants were compared with six spontaneously breathing preterm infants. INTERVENTIONS Random assignment of the order of the positions supine, prone, and quarter prone. MEASUREMENTS AND MAIN RESULTS Ventilation distribution was measured with regional impedance amplitudes and global inhomogeneity indices using electrical impedance tomography. In the spontaneously breathing infants, regional impedance amplitudes were increased in the posterior compared with the anterior lung (p < 0.01) and in the right compared with the left lung (p = 0.03). No differences were found in the ventilated infants. Ventilation was more inhomogeneous in the ventilated compared with the healthy infants (p < 0.01). Assessment of temporal regional lung filling showed that the posterior lung filled earlier than the anterior lung in the spontaneously breathing infants (p < 0.02) whereas in the in the ventilated infants the right lung filled before the left lung (p < 0.01). CONCLUSIONS In contrast to previous studies showing that ventilation is distributed to the nondependent lung in infants and children, this study shows that gravity has little effect on regional ventilation distribution.
Collapse
Affiliation(s)
- Judith L Hough
- Critical Care of the Newborn Program, Mater Medical Research Institute, South Brisbane, QLD, Australia.
| | | | | | | | | |
Collapse
|
39
|
Ferrario D, Grychtol B, Adler A, Sola J, Bohm SH, Bodenstein M. Toward Morphological Thoracic EIT: Major Signal Sources Correspond to Respective Organ Locations in CT. IEEE Trans Biomed Eng 2012; 59:3000-8. [DOI: 10.1109/tbme.2012.2209116] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
40
|
Thurgood J, Hooper S, Siew M, Wallace M, Dubsky S, Kitchen M, Jamison RA, Carnibella R, Fouras A. Functional lung imaging during HFV in preterm rabbits. PLoS One 2012; 7:e48122. [PMID: 23118938 PMCID: PMC3484156 DOI: 10.1371/journal.pone.0048122] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2012] [Accepted: 09/20/2012] [Indexed: 11/27/2022] Open
Abstract
Although high frequency ventilation (HFV) is an effective mode of ventilation, there is limited information available in regard to lung dynamics during HFV. To improve the knowledge of lung function during HFV we have developed a novel lung imaging and analysis technique. The technique can determine complex lung motion information in vivo with a temporal resolution capable of observing HFV dynamics. Using high-speed synchrotron based phase contrast X-ray imaging and cross-correlation analysis, this method is capable of recording data in more than 60 independent regions across a preterm rabbit lung in excess of 300 frames per second (fps). This technique is utilised to determine regional intra-breath lung mechanics of preterm rabbit pups during HFV. Whilst ventilated at fixed pressures, each animal was ventilated at frequencies of 1, 3, 5 and 10 Hz. A 50% decrease in delivered tidal volume was measured at 10 Hz compared to 1 Hz, yet at the higher frequency a 500% increase in minute activity was measured. Additionally, HFV induced greater homogeneity of lung expansion activity suggesting this ventilation strategy potentially minimizes tissue damage and improves gas mixing. The development of this technique permits greater insight and further research into lung mechanics and may have implications for the improvement of ventilation strategies used to support severe pulmonary trauma and disease.
Collapse
Affiliation(s)
- Jordan Thurgood
- Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, Victoria, Australia.
| | | | | | | | | | | | | | | | | |
Collapse
|
41
|
Hamilton SJ, Herrera CNL, Mueller JL, Von Herrmann A. A direct D-bar reconstruction algorithm for recovering a complex conductivity in 2-D. INVERSE PROBLEMS 2012; 28:095005. [PMID: 23641121 PMCID: PMC3638890 DOI: 10.1088/0266-5611/28/9/095005] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
A direct reconstruction algorithm for complex conductivities in W2,∞ (Ω), where Ω is a bounded, simply connected Lipschitz domain in ℝ2, is presented. The framework is based on the uniqueness proof by Francini [Inverse Problems 20 2000], but equations relating the Dirichlet-to-Neumann to the scattering transform and the exponentially growing solutions are not present in that work, and are derived here. The algorithm constitutes the first D-bar method for the reconstruction of conductivities and permittivities in two dimensions. Reconstructions of numerically simulated chest phantoms with discontinuities at the organ boundaries are included.
Collapse
Affiliation(s)
- S J Hamilton
- Department of Mathematics, Colorado State University, USA
| | | | | | | |
Collapse
|
42
|
Effect of body position on ventilation distribution in preterm infants on continuous positive airway pressure. Pediatr Crit Care Med 2012; 13:446-51. [PMID: 21926660 DOI: 10.1097/pcc.0b013e31822f18d9] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
RATIONALE Although continuous positive airway pressure is used extensively in neonatal intensive care units, and despite the belief that positioning is considered vital to the maintenance of good lung ventilation, no data exist on regional ventilation distribution in infants on continuous positive airway pressure ventilatory support. OBJECTIVES To investigate the effect of body position on regional ventilation in preterm infants on continuous positive airway pressure ventilatory support using electrical impedance tomography. DESIGN Randomized crossover study design. SETTING Neonatal intensive care unit. PATIENTS Twenty-four preterm infants on continuous positive airway pressure were compared to six spontaneously breathing preterm infants. INTERVENTIONS Random assignment of the order of the positions supine, prone, and quarter prone. MEASUREMENTS AND RESULTS Changes in global and regional lung volume were measured with electrical impedance tomography. Although there were no differences between positions, regional tidal volume was increased in the posterior compared with the anterior lung (p < .01) and in the right compared with the left lung (p < .03) in both the spontaneously breathing infants and in the infants on continuous positive airway pressure. The posterior lung filled earlier than the anterior lung in the spontaneously breathing infants (p < .02), whereas in the infants on continuous positive airway pressure the right lung filled before the left lung (p < .01). There was more ventilation inhomogeneity in the infants on continuous positive airway pressure than in the healthy infants (p < .01). CONCLUSIONS This study presents the first results on regional ventilation distribution in preterm infants on continuous positive airway pressure using electrical impedance tomography. Gravity had little impact on regional ventilation distribution in preterm infants on continuous positive airway pressure or in spontaneously breathing infants in the supine or prone position, indicating that ventilation distribution in preterm infants is not gravity-dependent but follows an anatomical pattern. AUSTRALIA NEW ZEALAND CLINICAL TRIALS REGISTRY:: ACTRN12606000210572.
Collapse
|
43
|
Nouvelles perspectives dans le monitoring respiratoire. MEDECINE INTENSIVE REANIMATION 2012. [DOI: 10.1007/s13546-011-0323-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
44
|
Abstract
PURPOSE OF REVIEW Electrical impedance tomography (EIT) is an attractive method of monitoring patients during mechanical ventilation because it can provide a noninvasive continuous image of pulmonary impedance, which indicates the distribution of ventilation. This article will discuss ongoing research on EIT, with a focus on methodological aspects and limitations and novel approaches in terms of pathophysiology, diagnosis and therapeutic advancements. RECENT FINDINGS EIT enables the detection of regional distribution of alveolar ventilation and, thus, the quantification of local inhomogeneities in lung mechanics. By detecting recruitment and derecruitment, a positive end-expiratory pressure level at which tidal ventilation is relatively homogeneous in all lung regions can be defined. Additionally, different approaches to characterize the temporal local behaviour of lung tissue during ventilation have been proposed, which adds important information. SUMMARY There is growing evidence that supports EIT usage as a bedside measure to individually optimize ventilator settings in critically ill patients in order to prevent ventilator-induced lung injury. A standardization of current approaches to analyse and interpret EIT data is required in order to facilitate the clinical implementation.
Collapse
|
45
|
Borges JB, Suarez-Sipmann F, Bohm SH, Tusman G, Melo A, Maripuu E, Sandström M, Park M, Costa ELV, Hedenstierna G, Amato M. Regional lung perfusion estimated by electrical impedance tomography in a piglet model of lung collapse. J Appl Physiol (1985) 2011; 112:225-36. [PMID: 21960654 DOI: 10.1152/japplphysiol.01090.2010] [Citation(s) in RCA: 127] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The assessment of the regional match between alveolar ventilation and perfusion in critically ill patients requires simultaneous measurements of both parameters. Ideally, assessment of lung perfusion should be performed in real-time with an imaging technology that provides, through fast acquisition of sequential images, information about the regional dynamics or regional kinetics of an appropriate tracer. We present a novel electrical impedance tomography (EIT)-based method that quantitatively estimates regional lung perfusion based on first-pass kinetics of a bolus of hypertonic saline contrast. Pulmonary blood flow was measured in six piglets during control and unilateral or bilateral lung collapse conditions. The first-pass kinetics method showed good agreement with the estimates obtained by single-photon-emission computerized tomography (SPECT). The mean difference (SPECT minus EIT) between fractional blood flow to lung areas suffering atelectasis was -0.6%, with a SD of 2.9%. This method outperformed the estimates of lung perfusion based on impedance pulsatility. In conclusion, we describe a novel method based on EIT for estimating regional lung perfusion at the bedside. In both healthy and injured lung conditions, the distribution of pulmonary blood flow as assessed by EIT agreed well with the one obtained by SPECT. The method proposed in this study has the potential to contribute to a better understanding of the behavior of regional perfusion under different lung and therapeutic conditions.
Collapse
Affiliation(s)
- João Batista Borges
- Department of Surgical Sciences, Section of Anaesthesiology and Critical Care, Uppsala University, Uppsala, Sweden.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
46
|
Humphreys S, Pham TMT, Stocker C, Schibler A. The effect of induction of anesthesia and intubation on end-expiratory lung level and regional ventilation distribution in cardiac children. Paediatr Anaesth 2011; 21:887-93. [PMID: 21395895 DOI: 10.1111/j.1460-9592.2011.03547.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND During the induction of anesthesia, changes in functional residual capacity and ventilation distribution (VD) occur. Although these physiological changes are well investigated in adults, little data are available in infants and children. AIM To describe continuous changes in lung physiology during the induction of anesthesia in infants and children using electrical impedance tomography (EIT). METHODS Lung mechanics and volume changes in 38 infants and children undergoing elective cardiac surgery were assessed using EIT before, during, and after the induction of anesthesia. End-expiratory level (EEL as an equivalent to FRC) and VD were measured with EIT and referenced to a period of spontaneous breathing prior to induction. RESULTS EEL changed significantly during induction with the lowest during the intubation phase and normalized with the application of positive end-expiratory pressures (PEEP) after induction. Ventilation prior to induction was preferentially distributed toward the dependent lung, whereas after induction, the nondependent lung was better ventilated. PEEP during mechanical ventilation did not improve ventilation inhomogeneity. CONCLUSION Lung volume and mechanics deteriorate significantly during the induction of anesthesia and remain altered during mechanical ventilation.
Collapse
Affiliation(s)
- Susan Humphreys
- Paediatric Critical Care Research Group, Mater Children's Hospital, South Brisbane, Qld., Australia
| | | | | | | |
Collapse
|
47
|
Reifferscheid F, Elke G, Pulletz S, Gawelczyk B, Lautenschläger I, Steinfath M, Weiler N, Frerichs I. Regional ventilation distribution determined by electrical impedance tomography: reproducibility and effects of posture and chest plane. Respirology 2011; 16:523-31. [PMID: 21261780 DOI: 10.1111/j.1440-1843.2011.01929.x] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND AND OBJECTIVE Reliable assessment of regional lung ventilation and good reproducibility of electrical impedance tomography (EIT) data are the prerequisites for the future application of EIT in a clinical setting. The aims of our study were to determine (i) the reproducibility of repeated EIT measurements and (ii) the effect of the studied transverse chest plane on ventilation distribution in different postures. METHODS Ten healthy adult subjects were studied in three postures on two separate days. EIT and spirometric data were obtained during tidal breathing and slow vital capacity (VC) manoeuvres. EIT data were acquired in two chest planes at 13 scans/s. Reproducibility of EIT findings was assessed by Bland-Altman analysis and Pearson correlation in 16 regions of interest in each plane. Regional ventilation distribution during tidal breathing and deep expiration was determined as fractional ventilation in four quadrants of the studied chest cross-sections. RESULTS Our study showed a good reproducibility of EIT measurements repeated after an average time interval of 8 days. Global tidal volumes and VCs determined by spirometry on separate days were not significantly different. Regional ventilation in chest quadrants assessed by EIT was also unaffected. Posture exerted a significant effect on ventilation distribution among the chest quadrants during spontaneous breathing and deep expiration in both planes. The spatial distribution patterns in the two planes were not identical. CONCLUSIONS We conclude that regional EIT ventilation findings are reproducible and recommend that the EIT examination location on the chest is carefully chosen especially during repeated measurements and follow-up.
Collapse
Affiliation(s)
- Florian Reifferscheid
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre Schleswig-Holstein-Campus Kiel, Kiel, Germany
| | | | | | | | | | | | | | | |
Collapse
|
48
|
Abstract
OBJECTIVE To investigate regional lung volume changes occurring during an inflation-deflation maneuver using high-frequency oscillatory ventilation. DESIGN Prospective animal trial. SETTING Animal research laboratory. SUBJECTS Six Yorkshire swine. INTERVENTIONS Electrical impedance tomography was used to quantify regional ventilation during high-frequency oscillatory ventilation. The electrical impedance tomography-derived center of ventilation was used to describe the distribution of regional ventilation, whereas spectral analysis was used to describe regional ventilation-induced impedance changes. Lung injury was induced using surfactant lavage. Animals were transitioned to high-frequency oscillatory ventilation and a slow inflation-deflation maneuver was performed by changing mean airway pressure by 5 cm H2O every 15 mins to a maximum mean airway pressure of 40 cm H2O. MEASUREMENTS AND MAIN RESULTS The induction of lung injury was associated with a significant shift of the center of ventilation toward nondependent areas and an increase in shunt fraction (p < .001). During the following inflation-deflation maneuver using high-frequency oscillatory ventilation, inflation was associated with a shift of the center of ventilation from nondependent to dependent areas. Center of ventilation was significantly correlated with the shunt fraction (p < .001). Analyzing different lung layers along the gravitational axis separately, nondependent lung areas showed significantly decreased regional ventilation-induced impedance changes at higher pressures, suggesting overdistension, whereas dependent lung areas showed increased impedance changes, suggesting recruitment. The reverse was observed during deflation (all p < .05). CONCLUSIONS The center of ventilation during high-frequency oscillatory ventilation correlated with oxygenating efficiency as measured by the shunt fraction. Lung recruitment during high-frequency oscillatory ventilation produced a significant shift of regional ventilation toward dependent areas of the lung and led to overdistension of nondependent areas.
Collapse
|
49
|
Wolf GK, Grychtol B, Boyd TK, Zurakowski D, Arnold JH. Regional overdistension identified with electrical impedance tomography in the perflubron-treated lung. Physiol Meas 2010; 31:S85-95. [PMID: 20647621 DOI: 10.1088/0967-3334/31/8/s07] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Regional lung overdistension occurring during high frequency oscillatory ventilation (HFOV) and partial liquid ventilation (PLV) was investigated in a prospective animal trial using 18 mechanically ventilated Yorkshire swine under general anesthesia. Lung injury was induced with saline lavage and augmented using large tidal volumes. Electrical impedance tomography (EIT) and regional lung histopathology were used to identify regional lung overdistension during HFOV. Lung injury was quantified using a histopathologic lung injury score. The animals were randomized to three groups (n = 6 animals in each group): a control group and two dose groups of perfluorooctyl bromide (PFOB) (PFOB-Lo 1.5 ml kg(-1) and PFOB-Hi 3 ml kg(-1)). The animals were transitioned from conventional ventilation to HFOV, and a slow inflation-deflation maneuver was performed by changing mean airway pressure (Paw) by 5 cmH(2)O every 15 min to a maximum Paw of 40 cmH(2)O. In dependent lung areas, the PFOB-Hi (3 ml kg(-1)) group, in comparison with the control group, was associated with significantly greater alveolar overdistension seen on lung histopathology (P < 0.001 compared to control), a decreased mean impedance (P < 0.05 compared to the control group) and a decreased ventilation-induced impedance change during HFOV (P < 0.05 compared to the control group). We conclude that treatment with PFOB-Hi during HFOV compared to a control group in an animal model of lung injury led to regional overdistension of dependent lung areas, as evidenced by increased alveolar overdistension on lung histopathology, decreased mean lung impedance and decreased HFOV-induced regional lung volume changes as measured by EIT.
Collapse
Affiliation(s)
- Gerhard K Wolf
- Division of Critical Care Medicine, Department of Anesthesiology, Perioperative and Pain Medicine, Children's Hospital Boston, Harvard Medical School, Boston, MA, USA.
| | | | | | | | | |
Collapse
|
50
|
Hahn G, Dittmar J, Just A, Quintel M, Hellige G. Different approaches for quantifying ventilation distribution and lung tissue properties by functional EIT. Physiol Meas 2010; 31:S73-84. [DOI: 10.1088/0967-3334/31/8/s06] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|