1
|
Ho AVT, Øvensen E, Lilja D, Toska K, Grenager O, Kristiansen K, Wesche J. Changes in electrodermal activity following sympathicotomy in hyperhidrosis patients. Front Surg 2024; 11:1358357. [PMID: 38529470 PMCID: PMC10961364 DOI: 10.3389/fsurg.2024.1358357] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Accepted: 02/22/2024] [Indexed: 03/27/2024] Open
Abstract
Objectives The aim of this study was to assess the potential of electrodermal activity (EDA) as a diagnostic tool for preoperative evaluation in hyperhidrosis patients. EDA levels and patterns in different skin areas were investigated before and after endoscopic thoracic sympathicotomy (ETS) and was compared to healthy subjects. Methods Thirty-seven patients underwent two days of measurements before and after the operation. Twenty-five (67.5%) of the patients also had a third measurement after six months. Non-invasive EDA measurements, involving skin conductance, were sampled from five different skin areas while patients were at rest in supine and sitting positions or when subjected to stimuli such as deep inspirations, mental challenge, and exposure to a sudden loud sound. Results Prior to the operation, hyperhidrosis patients showed higher spontaneous palm EDA variations at rest and stronger responses to stimuli compared to healthy subjects. Patients with facial blushing/hyperhidrosis or combined facial/palmar hyperhidrosis showed minimal spontaneous activity or responses, particularly during mental challenge and sound stimulus. Notably, palm EDA response was abolished shortly following sympathicotomy, although a minor response was observed after six months. Minimal EDA responses were also observed in the back and abdomen postoperatively. Conclusion Hyperhidrosis patients showed stronger EDA response to stimuli compared to healthy subjects. Sympathicotomy resulted in the complete elimination of palm EDA responses, gradually returning to a limited extent after six months. These findings suggest that EDA recordings could be utilized in preoperative assessment of hyperhidrosis patients.
Collapse
Affiliation(s)
- Ai Van Thuy Ho
- The Faculty of Medicine, Institute of Clinical Medicine, University of Oslo, Oslo, Norway
- Department of Thoracic and Vascular Surgery, Akershus University Hospital, Lørenskog, Norway
| | - Eirik Øvensen
- Department of Thoracic and Vascular Surgery, Akershus University Hospital, Lørenskog, Norway
| | - Didrik Lilja
- The Intervention Centre, Oslo University Hospital, Oslo, Norway
| | - Karin Toska
- The Faculty of Medicine, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway
- Department of Medical Biochemistry, Oslo University Hospital, Oslo, Norway
| | - Odd Grenager
- Department of Thoracic and Vascular Surgery, Akershus University Hospital, Lørenskog, Norway
| | - Knut Kristiansen
- Department of Thoracic and Vascular Surgery, Akershus University Hospital, Lørenskog, Norway
| | - Jarlis Wesche
- The Faculty of Medicine, Institute of Clinical Medicine, University of Oslo, Oslo, Norway
- Department of Thoracic and Vascular Surgery, Akershus University Hospital, Lørenskog, Norway
| |
Collapse
|
2
|
Tran HT, Kong Y, Talati A, Posada-Quintero H, Chon KH, Chen IP. The use of electrodermal activity in pulpal diagnosis and dental pain assessment. Int Endod J 2023; 56:356-368. [PMID: 36367715 PMCID: PMC10044487 DOI: 10.1111/iej.13868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 11/07/2022] [Accepted: 11/08/2022] [Indexed: 11/13/2022]
Abstract
AIMS To explore whether electrodermal activity (EDA) can serve as a complementary tool for pulpal diagnosis (Aim 1) and an objective metric to assess dental pain before and after local anaesthesia (Aim 2). METHODOLOGY A total of 53 subjects (189 teeth) and 14 subjects (14 teeth) were recruited for Aim 1 and Aim 2, respectively. We recorded EDA using commercially available devices, PowerLab and Galvanic Skin Response (GSR) Amplifier, in conjunction with cold and electric pulp testing (EPT). Participants rated their level of sensation on a 0-10 visual analogue scale (VAS) after each test. We recorded EPT-stimulated EDA activity before and after the administration of local anaesthesia for participants who required root canal treatment (RCT) due to painful pulpitis. The raw data were converted to the time-varying index of sympathetic activity (TVSymp), a sensitive and specific parameter of EDA. Statistical analysis was performed using Python 3.6 and its Scikit-post hoc library. RESULTS Electrodermal activity was upregulated by the stimuli of cold and EPT testing in the normal pulp. TVSymp signals were significantly increased in vital pulp compared to necrotic pulp by both cold test and EPT. Teeth that exhibited intensive sensitivity to cold with or without lingering pain had increased peak numbers of TVSymp than teeth with mild sensation to cold. Pre- and post-anaesthesia EDA activity and VAS scores were recorded in patients with painful pulpitis. Post-anaesthesia EDA signals were significantly lower compared to pre-anaesthesia levels. Approximately 71% of patients (10 of 14 patients) experienced no pain during treatment and reported VAS score of 0 or 1. The majority of patients (10 of 14) showed a reduction of TVSymp after the administration of anaesthesia. Two of three patients who experienced increased pain during RCT (post-treatment VAS > pre-treatment VAS) exhibited increased post-anaesthesia TVSymp. CONCLUSIONS Our data show promising results for using EDA in pulpal diagnosis and for assessing dental pain. Whilst our testing was limited to subjects who had adequate communication skills, our future goal is to be able to use this technology to aid in the endodontic diagnosis of patients who have limited communication ability.
Collapse
Affiliation(s)
- Hanh T Tran
- Department of Oral Health and Diagnostic Sciences, School of Dental Medicine, University of Connecticut Health, Farmington, Connecticut, USA
| | - Youngsun Kong
- Department of Biomedical Engineering, School of Engineering, University of Connecticut, Storrs, Connecticut, USA
| | - Ankur Talati
- Department of Oral Health and Diagnostic Sciences, School of Dental Medicine, University of Connecticut Health, Farmington, Connecticut, USA
| | - Hugo Posada-Quintero
- Department of Biomedical Engineering, School of Engineering, University of Connecticut, Storrs, Connecticut, USA
| | - Ki H Chon
- Department of Biomedical Engineering, School of Engineering, University of Connecticut, Storrs, Connecticut, USA
| | - I-Ping Chen
- Department of Oral Health and Diagnostic Sciences, School of Dental Medicine, University of Connecticut Health, Farmington, Connecticut, USA
| |
Collapse
|
3
|
Tronstad C, Pabst O, Amini M, Kleggetveit IP, Elvebakk O, Martinsen OG, Jenssen TG, Hisdal J, Berg TJ, Qvigstad E. Development of a prototype toe sensor for detection of diabetic peripheral small fiber neuropathy. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:99-104. [PMID: 36086669 DOI: 10.1109/embc48229.2022.9871101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Diabetic peripheral neuropathy (DPN) affects a large proportion of people with diabetes, and early detection is essential to prevent further progression. Widespread clinical testing relies on simplicity and cost-effectiveness of examination. Early signs of DPN may be detected by assessing the sudomotor nerves, and sudomotor activity can be measured by bioimpedance. We present a prototype toe probe for DPN detection including sensors for measuring skin AC conductance, skin temperature and humidity. The prototype was tested on five participants with DPN and five healthy age-matched controls in a pilot study. Sudomotor sensor responses to a simple deep breathing test were very weak or absent in the DPN group, with all controls having larger responses than the DPN group. Evaporation was lower for the DPN group, and skin temperature was higher on average. For the same foot, the results for sudomotor responses were in agreement with sensory neurography amplitudes from the sural nerve whereas the monofilament test gave normal results for two of the DPN participants. If sufficient detection accuracy is confirmed in larger studies, the method may provide a simple and cost-effective tool to support clinical examination. Clinical Relevance- We present the early realization and testing of a simple device to support early detection of diabetic peripheral neuropathy.
Collapse
|
4
|
Tronstad C, Amini M, Bach DR, Martinsen OG. Current trends and opportunities in the methodology of electrodermal activity measurement. Physiol Meas 2022; 43. [PMID: 35090148 DOI: 10.1088/1361-6579/ac5007] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Accepted: 01/28/2022] [Indexed: 11/12/2022]
Abstract
Electrodermal activity (EDA) has been measured in the laboratory since the late 1800s. Although the influence of sudomotor nerve activity and the sympathetic nervous system on EDA is well established, the mechanisms underlying EDA signal generation are not completely understood. Owing to simplicity of instrumentation and modern electronics, these measurements have recently seen a transfer from the laboratory to wearable devices, sparking numerous novel applications while bringing along both challenges and new opportunities. In addition to developments in electronics and miniaturization, current trends in material technology and manufacturing have sparked innovations in electrode technologies, and trends in data science such as machine learning and sensor fusion are expanding the ways that measurement data can be processed and utilized. Although challenges remain for the quality of wearable EDA measurement, ongoing research and developments may shorten the quality gap between wearable EDA and standardized recordings in the laboratory. In this topical review, we provide an overview of the basics of EDA measurement, discuss the challenges and opportunities of wearable EDA, and review recent developments in instrumentation, material technology, signal processing, modeling and data science tools that may advance the field of EDA research and applications over the coming years.
Collapse
Affiliation(s)
- Christian Tronstad
- Department of Clinical and Biomedical Engineering, Oslo University Hospital, Sognsvannsveien 20, Oslo, 0372, NORWAY
| | - Maryam Amini
- Physics, University of Oslo Faculty of Mathematics and Natural Sciences, Sem Sælands vei 24, Oslo, 0371, NORWAY
| | - Dominik R Bach
- Wellcome Centre for Human Neuroimaging, University College London, 12 Queen Square, London, London, WC1N 3AZ, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | | |
Collapse
|
5
|
Ho AVT, Toska K, Wesche J. Rapid, Large, and Synchronous Sweat and Cardiovascular Responses Upon Minor Stimuli in Healthy Subjects. Dynamics and Reproducibility. Front Neurol 2020; 11:51. [PMID: 32117014 PMCID: PMC7010925 DOI: 10.3389/fneur.2020.00051] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Accepted: 01/14/2020] [Indexed: 11/13/2022] Open
Abstract
Purpose: The aim of the study was to investigate steady state levels, dynamics and reproducibility of cardiovascular variables and electrodermal activity in different skin areas in response to minor physiological and mental stimuli in healthy subjects in the thermoneutral zone, carried out in high time resolution. Methods: Thirteen healthy subjects underwent experiments on two separate days. Non-invasive electrodermal activity in five different skin areas was measured continuously using a skin conductance method, including resting supine and sitting positions, performing deep inspirations, a mental challenge and being exposed to a sudden loud sound. Blood pressure, heart rate, radial artery blood flow, and skin perfusion were measured simultaneously. Results: Electrodermal activity in the right and left palms was almost identical, with rapid and large increases within a few seconds in response to stimuli, whereas no such significant changes were seen in the face, back, and abdomen. Radial artery blood flow and palmar skin perfusion changed synchronously with electrodermal activity for each stimulus, and were correlated to changes in blood pressure and heart rate. The response patterns in each subject were very similar on the two experimental days. There was very low spontaneous electrodermal activity in the supine position, contrary to the resting sitting position. Conclusion: The electrodermal activity increased rapidly and synchronously in both palms within a few seconds as a response to minor physiological and mental stimuli, synchronous with fluctuations in radial artery blood flow, palmar skin perfusion, and cardiovascular variables. The responses are reproducible from day to day, making them a stable and constant stimuli to be used for studies in patients with hyperhidrosis.
Collapse
Affiliation(s)
- Ai Van Thuy Ho
- Faculty of Medicine, Institute of Clinical Medicine, University of Oslo, Oslo, Norway.,Department of Vascular and Thoracic Surgery, Akershus University Hospital, Lørenskog, Norway
| | - Karin Toska
- Department of Physiology, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway.,Department of Medical Biochemistry, Oslo University Hospital, Oslo, Norway
| | - Jarlis Wesche
- Faculty of Medicine, Institute of Clinical Medicine, University of Oslo, Oslo, Norway.,Department of Vascular and Thoracic Surgery, Akershus University Hospital, Lørenskog, Norway
| |
Collapse
|
6
|
Bjørhei A, Pedersen FT, Muhammad S, Tronstad C, Kalvøy H, Wojniusz S, Pabst O, Sütterlin S. An Investigation on Bilateral Asymmetry in Electrodermal Activity. Front Behav Neurosci 2019; 13:88. [PMID: 31133830 PMCID: PMC6514357 DOI: 10.3389/fnbeh.2019.00088] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Accepted: 04/11/2019] [Indexed: 11/29/2022] Open
Abstract
The Multiple Arousal Theory (Picard et al., 2016) was proposed to explain retrospective observations of bilateral differences in electrodermal activities occurring in threat-related high-stake situations. The theory proposes different cortical and subcortical structures to be involved in the processing of various facets of emotional states. Systematic investigations of this effect are still scarce. This study tested the prediction of bilateral electrodermal effects in a controlled laboratory environment where electrodermal activity (EDA) was recorded bilaterally during normal activity and two stress-tasks in 25 healthy volunteers. A visual search stress task with a performance-related staircase algorithm was used, ensuring intersubjectively comparable stress levels across individuals. After completion of the task, a sense of ownership of an attractive price was created and loss aversion introduced to create a high-stake situation. Confirmation of the theory should satisfy the hypothesis of a bilateral difference in EDA between the dominant and non-dominant hand, which is larger during high-stake stressors than during low-stake stressors. The bilateral difference was quantified and compared statistically between the two stress-tasks, revealing no significant difference between them nor any significant difference between the stress tasks and the period of normal activity. Subgroup analysis of only the participants with maximum self-rating of their desire to win the price (n = 7) revealed neither any significant difference between the two tasks nor between the stress-tasks and the period of normal activity. Although the theory was not confirmed by this study, eight cases suggestive of bilateral difference within the recordings were identified and are presented. Because the study is limited in using one of several possible operationalizations of the phenomenon, it is not possible to draw a general conclusion on the theory. Nevertheless, the study might contribute to a better understanding and encourage systematic review and hypothesis development regarding this new theory. Possible explanations and suggestions for future pathways to systematically investigate the Multiple Arousal Theory are discussed.
Collapse
Affiliation(s)
- Andreas Bjørhei
- Department of Mechanical, Electronic and Chemical Engineering, Oslo Metropolitan University, Oslo, Norway
| | - Filip T. Pedersen
- Department of Mechanical, Electronic and Chemical Engineering, Oslo Metropolitan University, Oslo, Norway
| | - Saeed Muhammad
- Department of Mechanical, Electronic and Chemical Engineering, Oslo Metropolitan University, Oslo, Norway
| | - Christian Tronstad
- Department of Clinical and Biomedical Engineering, Oslo University Hospital, Oslo, Norway
| | - Håvard Kalvøy
- Department of Clinical and Biomedical Engineering, Oslo University Hospital, Oslo, Norway
| | - Slawomir Wojniusz
- Department of Physiotherapy, Faculty of Health Sciences, Oslo Metropolitan University, Oslo, Norway
- Division of Clinical Neuroscience, Oslo University Hospital, Oslo, Norway
| | - Oliver Pabst
- Department of Physics, University of Oslo, Oslo, Norway
| | - Stefan Sütterlin
- Division of Clinical Neuroscience, Oslo University Hospital, Oslo, Norway
- Faculty of Health and Welfare Sciences, Østfold University College, Halden, Norway
| |
Collapse
|
7
|
Andò A, Girolamo MD, Pignolo C, Zennaro A, Giromini L, Minichino A, Salatino A, Morese R. Personality features and vulnerability to stress: a case study on hyperhidrosis. RESEARCH IN PSYCHOTHERAPY 2019; 22:344. [PMID: 32913779 PMCID: PMC7451363 DOI: 10.4081/ripppo.2019.344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Accepted: 02/01/2019] [Indexed: 11/30/2022]
Abstract
By using the Rorschach test, self-reports, and psychophysiological measures, we investigated thoroughly the psychological functioning in a hyperhidrotic case. Erica, a young female with hyperhidrosis, was assessed in three times at one-week distance. First, specific tools assessing potential psychological and affective distress, and the Rorschach test were administered. About one week later, Electrodermal Activity was recorded during the exposure to a mild laboratory stress-inducing task. Finally, a magnetic resonance imaging exam was performed in order to exclude medical conditions/neurological alterations for potential physiological anomalies. Erica tends to avoid living in the moment and prefers to experience close relationships in her inner world where she can rehearse the future and imagine different contexts and social situations without risks and embarrassment. She reports high capacities to perform goaldirected behaviors and clarity of emotions only in absence of stressful situations. The study has the merit to be the first to combine Rorschach data with physiological data in order to investigate the psychological functioning in a hyperhidrotic case.
Collapse
Affiliation(s)
- Agata Andò
- Department of Psychology, University of Turin, Italy
| | | | | | | | | | | | | | - Rosalba Morese
- Department of Psychology, University of Turin, Italy.,Faculty of Communication Sciences, Università della Svizzera Italiana, Lugano, Switzerland
| |
Collapse
|
8
|
Salvo P, Pingitore A, Barbini A, Di Francesco F. A wearable sweat rate sensor to monitor the athletes’ performance during training. Sci Sports 2018. [DOI: 10.1016/j.scispo.2017.03.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
9
|
Skjærvø Ø, Brandtzaeg OK, Lausund KB, Pabst O, Martinsen ØG, Lundanes E, Wilson SR. Exploring bioimpendance instrumentation for the characterization of open tubular liquid chromatography columns. J Chromatogr A 2018; 1534:195-200. [DOI: 10.1016/j.chroma.2017.12.060] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2017] [Revised: 12/21/2017] [Accepted: 12/21/2017] [Indexed: 11/26/2022]
|
10
|
Tronstad C, Elvebakk O, Kalvoy H, Bjorgaas MR, Martinsen OG. Detection of sympathoadrenal discharge by parameterisation of skin conductance and ECG measurement. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2017:3997-4000. [PMID: 29060773 DOI: 10.1109/embc.2017.8037732] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Detection of sympathoadrenal discharge is valuable for stress monitoring, but measuring the circulating adrenaline level directly is inconvenient, making non-invasive physiological sensors an attractive alternative. Little is known however, about their performance in detecting different adrenaline levels. In this study, adrenaline measurements over time from 20 subjects × 2 trials were compared with skin conductance (SC) from different skin sites and ECG recordings from which the heart rate and QT interval were derived. The frequency of sudomotor responses (FSR) was derived from the SC recording, and a new composite parameter for amplification of synchronous changes in multiple sensor signals was calculated for different combinations of FSR from different skin sites, heart rate and QT interval. The single and composite parameters were evaluated for detection performance of adrenaline levels above 1000, 1500 and 2000 pmol/L. The best prediction performance was indicated for the composite parameter using the FSR from the abdomen, FSR from the forehead and the heart rate, with a ROC area under the curve of 0.93 for the 2000 pmol/L threshold. In conclusion, detection of strong sympathoadrenal discharges is feasible with good accuracy during resting conditions in comfortable room temperature.
Collapse
|
11
|
Yokus MA, Hass C, Agcayazi T, Bozkurt A, Daniele MA. Towards a wearable perspiration sensor. 2017 IEEE SENSORS 2017. [DOI: 10.1109/icsens.2017.8234296] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
12
|
Pabst O, Tronstad C, Grimnes S, Fowles D, Martinsen ØG. Comparison between the AC and DC measurement of electrodermal activity. Psychophysiology 2016; 54:374-385. [PMID: 28000290 DOI: 10.1111/psyp.12803] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2016] [Revised: 10/24/2016] [Accepted: 11/02/2016] [Indexed: 10/20/2022]
Abstract
Recording electrodermal activity is a well-accepted physiological measurement for clinical approaches and research. Historically, applying a DC (direct current) signal to the skin to measure the conductance is the most common practice for exogenous recordings. However, this method can be subject to error due to electrode polarization even with "nonpolarizing" electrodes-a problem that can be eliminated with alternating current (AC) methodology. For that reason, Boucsein et al. () called for research demonstrating an AC method that is validated by comparison to standard DC methodology. Additionally, the complex structure of human skin has electrical properties that include both resistance and capacitance, and AC recording enables the measurement of skin susceptance (associated with current flow through capacitors). Finally, AC recording permits the simultaneous recording of the endogenous skin potential. In this paper, the results from a direct comparison between both methods are presented, which has not been reported previously. The results demonstrated excellent agreement between a 20 Hz AC method and a standard DC method, supporting the validity of the AC recording methodology employed. The results also showed that an applied voltage of 0.2 V is sufficient for DC recordings.
Collapse
Affiliation(s)
- Oliver Pabst
- Department of Physics, University of Oslo, Oslo, Norway
| | - Christian Tronstad
- Department of Clinical and Biomedical Engineering, Oslo University Hospital HF, Oslo, Norway
| | - Sverre Grimnes
- Department of Physics, University of Oslo, Oslo, Norway.,Department of Clinical and Biomedical Engineering, Oslo University Hospital HF, Oslo, Norway
| | - Don Fowles
- Department of Psychological & Brain Sciences, University of Iowa, Iowa City, Iowa, USA
| | - Ørjan G Martinsen
- Department of Physics, University of Oslo, Oslo, Norway.,Department of Clinical and Biomedical Engineering, Oslo University Hospital HF, Oslo, Norway
| |
Collapse
|
13
|
Seno SI, Nemoto T, Fukuoka M, Watanabe A, Kato S, Kogure E, Kobayashi H, Shimazu H. Quantitative Evaluation of an Unrestrictive Sweat Rate Measurement Device. ADVANCED BIOMEDICAL ENGINEERING 2016. [DOI: 10.14326/abe.5.76] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Affiliation(s)
| | - Tetsu Nemoto
- Department of Clinical Laboratory Science, Graduate School of Medical Science, Kanazawa University
| | - Masakazu Fukuoka
- Advanced Research Center for Human Sciences, Waseda University
- Rousette Strategy Inc
| | | | | | - Eiki Kogure
- Faculty of Health Sciences, Kyorin University
| | | | | |
Collapse
|
14
|
Abstract
The purpose of this review is to describe the unique anatomical and physiological features of the hands and feet that support heat conservation and dissipation, and in so doing, highlight the importance of these appendages in human thermoregulation. For instance, the surface area to mass ratio of each hand is 4-5 times greater than that of the body, whilst for each foot, it is ~3 times larger. This characteristic is supported by vascular responses that permit a theoretical maximal mass flow of thermal energy of 6.0 W (136 W m(2)) to each hand for a 1 °C thermal gradient. For each foot, this is 8.5 W (119 W m(2)). In an air temperature of 27 °C, the hands and feet of resting individuals can each dissipate 150-220 W m(2) (male-female) of heat through radiation and convection. During hypothermia, the extremities are physiologically isolated, restricting heat flow to <0.1 W. When the core temperature increases ~0.5 °C above thermoneutral (rest), each hand and foot can sweat at 22-33 mL h(-1), with complete evaporation dissipating 15-22 W (respectively). During heated exercise, sweat flows increase (one hand: 99 mL h(-1); one foot: 68 mL h(-1)), with evaporative heat losses of 67-46 W (respectively). It is concluded that these attributes allow the hands and feet to behave as excellent radiators, insulators and evaporators.
Collapse
|
15
|
Hands and feet: physiological insulators, radiators and evaporators. Eur J Appl Physiol 2014; 114:2037-60. [DOI: 10.1007/s00421-014-2940-8] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2013] [Accepted: 06/16/2014] [Indexed: 10/25/2022]
|
16
|
Nordbotten BJ, Tronstad C, Martinsen ØG, Grimnes S. Estimation of skin conductance at low frequencies using measurements at higher frequencies for EDA applications. Physiol Meas 2014; 35:1011-8. [PMID: 24844405 DOI: 10.1088/0967-3334/35/6/1011] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Using low-frequency (LF) alternating current skin conductance (SC) has recently been recommended for electrodermal activity (EDA) measurement, but the method may imply some limitations in sampling rate, which are insufficient for capturing the complete SC waveform. The aim of this study was to assess whether LF SC can be estimated based on skin admittance (SA) measurements at higher frequencies allowing higher sampling rates. SA measurements from 1 Hz to 70 kHz were gathered from 20 healthy human participants, and an interval from 500 Hz to 10 kHz was used to fit a Cole model to the measured SA by means of the nonlinear least squares method. The LF extrapolation of this fit was used to estimate the LF SC at 1, 10, 22 and 30 Hz. The method produced an overestimation of SC by approximately 20%, and the variation in LF SC was preserved by approximately 95%. The overestimation is most likely due to different frequency dependence behavior (dispersion) of SC at the lowest frequencies, which is not accounted for by a single dispersion model. In conclusion, the SA method using high frequency is unsuitable for estimation of the LF SC level, but can probably be used in EDA measurements, which are scored based on the variations in SC.
Collapse
|
17
|
Filingeri D, Redortier B, Hodder S, Havenith G. The role of decreasing contact temperatures and skin cooling in the perception of skin wetness. Neurosci Lett 2013; 551:65-9. [PMID: 23886487 DOI: 10.1016/j.neulet.2013.07.015] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2013] [Revised: 07/02/2013] [Accepted: 07/08/2013] [Indexed: 12/19/2022]
Abstract
Cold sensations are suggested as the primary inducer of the perception of skin wetness. However, limited data are available on the effects of skin cooling. Hence, we investigated the role of peripheral cold afferents in the perception of wetness. Six cold-dry stimuli (producing skin cooling rates in a range of 0.02-0.41°C/s) were applied on the forearm of 9 female participants. Skin temperature and conductance, thermal and wetness perception were recorded. Five out of 9 participants perceived wetness as a result of cold-dry stimuli with cooling rates in a range of 0.14-0.41°C/s, while 4 did not perceive skin wetness at all. Although skin cooling and cold sensations play a role in evoking the perception of wetness, these are not always of a primary importance and other sensory modalities (i.e. touch and vision), as well as the inter-individual variability in thermal sensitivity, might be equally determinant in characterising this perception.
Collapse
Affiliation(s)
- Davide Filingeri
- Environmental Ergonomics Research Centre, Loughborough Design School, Loughborough University, Loughborough LE11 3TU, UK.
| | | | | | | |
Collapse
|
18
|
Taylor NA, Machado-Moreira CA. Regional variations in transepidermal water loss, eccrine sweat gland density, sweat secretion rates and electrolyte composition in resting and exercising humans. EXTREME PHYSIOLOGY & MEDICINE 2013; 2:4. [PMID: 23849497 PMCID: PMC3710196 DOI: 10.1186/2046-7648-2-4] [Citation(s) in RCA: 250] [Impact Index Per Article: 22.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/17/2012] [Accepted: 12/06/2012] [Indexed: 11/10/2022]
Abstract
Literature from the past 168 years has been filtered to provide a unified summary of the regional distribution of cutaneous water and electrolyte losses. The former occurs via transepidermal water vapour diffusion and secretion from the eccrine sweat glands. Daily insensible water losses for a standardised individual (surface area 1.8 m2) will be 0.6-2.3 L, with the hands (80-160 g.h-1) and feet (50-150 g.h-1) losing the most, the head and neck losing intermediate amounts (40-75 g.h-1) and all remaining sites losing 15-60 g.h-1. Whilst sweat gland densities vary widely across the skin surface, this same individual would possess some 2.03 million functional glands, with the highest density on the volar surfaces of the fingers (530 glands.cm-2) and the lowest on the upper lip (16 glands.cm-2). During passive heating that results in a resting whole-body sweat rate of approximately 0.4 L.min-1, the forehead (0.99 mg.cm-2.min-1), dorsal fingers (0.62 mg.cm-2.min-1) and upper back (0.59 mg.cm-2.min-1) would display the highest sweat flows, whilst the medial thighs and anterior legs will secrete the least (both 0.12 mg.cm-2.min-1). Since sweat glands selectively reabsorb electrolytes, the sodium and chloride composition of discharged sweat varies with secretion rate. Across whole-body sweat rates from 0.72 to 3.65 mg.cm-2.min-1, sodium losses of 26.5-49.7 mmol.L-1 could be expected, with the corresponding chloride loss being 26.8-36.7 mmol.L-1. Nevertheless, there can be threefold differences in electrolyte losses across skin regions. When exercising in the heat, local sweat rates increase dramatically, with regional glandular flows becoming more homogeneous. However, intra-regional evaporative potential remains proportional to each local surface area. Thus, there is little evidence that regional sudomotor variations reflect an hierarchical distribution of sweating either at rest or during exercise.
Collapse
Affiliation(s)
- Nigel As Taylor
- Centre for Human and Applied Physiology, School of Health Sciences, University of Wollongong, Wollongong, New South Wales, 2522, Australia.
| | | |
Collapse
|
19
|
van Dooren M, de Vries JJGGJ, Janssen JH. Emotional sweating across the body: comparing 16 different skin conductance measurement locations. Physiol Behav 2012; 106:298-304. [PMID: 22330325 DOI: 10.1016/j.physbeh.2012.01.020] [Citation(s) in RCA: 137] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2011] [Revised: 01/19/2012] [Accepted: 01/30/2012] [Indexed: 11/30/2022]
Abstract
Skin conductance (SC) is one of the most commonly used measures in psychophysiological studies involving emotional arousal and is traditionally measured at the fingers or the palms (i.e., the palmar locations) of the hand. Palmar skin conductance recording positions are, however, not always preferred for ambulatory recordings in real-life situations. This study quantifies the responsiveness and similarity with the finger of 16 different recording positions of skin conductance while watching emotional film fragments. Findings indicated foot, fingers and shoulders being most responsive, whereas arm, back, armpit, and thighbone were least responsive. The measurements at the foot were most similar with those of the finger. In contrast, arm, back, and armpit traces differed most from the finger trace. Taken together, foot and shoulders are the best alternatives to the finger for ambulatory measurement of skin conductance to reflect emotional arousal. These findings can help new applications using skin conductance, like automated emotion measurements, to come to fruition.
Collapse
Affiliation(s)
- Marieke van Dooren
- Philips Research Europe, High Tech Campus 34, 5656 AE Eindhoven, The Netherlands.
| | | | | |
Collapse
|
20
|
Dewarrat F, Falco L, Mueller M, Reinhard S, Caduff A, Talary MS. A dielectric inverse problem applied to human skin measurements during glucose excursions. Physiol Meas 2011; 32:1285-300. [PMID: 21743123 DOI: 10.1088/0967-3334/32/8/018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A fringing field capacitive sensor has been used to measure the dielectric properties of human skin and underlying tissue in the MHz frequency range. It has recently been shown in clinical experimental studies that these dielectric properties can be related to the effects of in vivo glucose variations of the test subject. Previously, the relationship between electrical impedance and the glucose level has been established via statistical methods, such as the regression method. In this work, we explored a different approach, namely the resolution of the so-called inverse problem. First we applied the method on an artificial two-layer lossy system in order to test the sensitivity of the solution to forced changes in the layer properties and its stability to a constant setting. After validation of this method on artificial systems, a similar inverse problem was set and solved for dielectric measurements on human skin during an induced glucose excursion, where the skin is also modelled as a double-layer system. The changes of the measured permittivity and conductivity of the second layer versus the glucose changes are calculated for 22 study days. The statistical distribution shows that the median slopes of both dielectric properties are negative. These results can be used to test our hypothesis and to continue building potential explanations for the phenomena induced by the glucose changes on the skin layer dielectric parameters.
Collapse
Affiliation(s)
- F Dewarrat
- Solianis Monitoring AG, Leutschenbachstrasse 46, Zurich 8050, Switzerland
| | | | | | | | | | | |
Collapse
|
21
|
Grimnes S, Jabbari A, Martinsen ØG, Tronstad C. Electrodermal activity by DC potential and AC conductance measured simultaneously at the same skin site. Skin Res Technol 2011; 17:26-34. [DOI: 10.1111/j.1600-0846.2010.00459.x] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
22
|
Birgersson U, Birgersson E, Åberg P, Nicander I, Ollmar S. Non-invasive bioimpedance of intact skin: mathematical modeling and experiments. Physiol Meas 2010; 32:1-18. [DOI: 10.1088/0967-3334/32/1/001] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
23
|
Tronstad C, Johnsen GK, Grimnes S, Martinsen ØG. A study on electrode gels for skin conductance measurements. Physiol Meas 2010; 31:1395-410. [DOI: 10.1088/0967-3334/31/10/008] [Citation(s) in RCA: 66] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
24
|
Increase of electrodermal activity of heart meridian during physical exercise: The significance of electrical values in acupuncture and diagnostic importance. Complement Ther Clin Pract 2010; 16:149-153. [DOI: 10.1016/j.ctcp.2010.01.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2009] [Revised: 01/08/2010] [Accepted: 01/12/2010] [Indexed: 11/23/2022]
|
25
|
Poh MZ, Swenson NC, Picard RW. A wearable sensor for unobtrusive, long-term assessment of electrodermal activity. IEEE Trans Biomed Eng 2010; 57:1243-52. [PMID: 20172811 DOI: 10.1109/tbme.2009.2038487] [Citation(s) in RCA: 202] [Impact Index Per Article: 14.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Electrodermal activity (EDA) is a sensitive index of sympathetic nervous system activity. Due to the lack of sensors that can be worn comfortably during normal daily activity and over extensive periods of time, research in this area is limited to laboratory settings or artificial clinical environments. We developed a novel, unobtrusive, nonstigmatizing, wrist-worn integrated sensor, and present, for the very first time, a demonstration of long-term, continuous assessment of EDA outside of a laboratory setting. We evaluated the performance of our device against a Food and Drug Administration (FDA) approved system for the measurement of EDA during physical, cognitive, as well as emotional stressors at both palmar and distal forearm sites, and found high correlations across all the tests. We also evaluated the choice of electrode material by comparing conductive fabric with Ag/AgCl electrodes and discuss the limitations found. An important result presented in this paper is evidence that the distal forearm is a viable alternative to the traditional palmar sites for EDA measurements. Our device offers the unprecedented ability to perform comfortable, long-term, and in situ assessment of EDA. This paper opens up opportunities for future investigations that were previously not feasible, and could have far-reaching implications for diagnosis and understanding of psychological or neurological conditions.
Collapse
Affiliation(s)
- Ming-Zher Poh
- Harvard-MIT Division of Health Sciences and Technology (HST), Cambridge, MA 02139, USA.
| | | | | |
Collapse
|