1
|
Guendouz Y, Razif NAM, Bernasconi F, Brien GO, Johnston RD, Lally C. Simulating atherosclerotic plaque mechanics using polyvinyl alcohol (PVA) cryogel artery phantoms, ultrasound imaging and inverse finite element analysis. Phys Med Biol 2024; 69:245020. [PMID: 39626619 DOI: 10.1088/1361-6560/ad9a4b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Accepted: 12/03/2024] [Indexed: 12/20/2024]
Abstract
The clinical decision to establish if a patient with carotid disease should undergo surgical intervention is primarily based on the percent stenosis. Whilst this applies for high-grade stenosed vessels (>70%), it falls short for other cases. Due to the heterogeneity of plaque tissue, probing the mechanics of the tissue would likely provide further insights into why some plaques are more prone to rupture. Mechanical characterization of such tissue is nontrivial, however, due to the difficulties in collecting fresh, intact plaque tissue and using physiologically relevant mechanical testing of such material. The use of polyvinyl alcohol (PVA) cryogel is thus highly convenient because of its acoustic properties and tunable mechanical properties.Methods.The aim of this study is to demonstrate the potential of PVA phantoms to simulate atherosclerotic features. In addition, a testing and simulation framework is developed for full PVA vessel material characterization using ring tensile testing and inflation testing combined with non-invasive ultrasound imaging and computational modeling.Results.Strain stiffening behavior was observed in PVA through ring tensile tests, particularly at high (n= 6) freeze-thaw cycles (FTCs). Inflation testing of bi-layered phantoms featuring lipid pool inclusions demonstrated high strains at shoulder regions. The application of an inverse finite element framework successfully recovered boundaries and determined the shear moduli for the PVA wall to lie within the range 27-53 kPa.Conclusion.The imaging-modeling framework presented facilitates the use and characterization of arterial mimicking phantoms to further explore plaque rupture. It also shows translational potential for non-invasive mechanical characterization of atherosclerotic plaques to improve the identification of clinically relevant metrics of plaque vulnerability.
Collapse
Affiliation(s)
- Yasmine Guendouz
- Trinity Centre for Biomedical Engineering, Trinity College Dublin, Dublin, Ireland
- Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland
| | - Noor Adeebah Mohamed Razif
- Trinity Centre for Biomedical Engineering, Trinity College Dublin, Dublin, Ireland
- Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland
| | - Floriane Bernasconi
- Trinity Centre for Biomedical Engineering, Trinity College Dublin, Dublin, Ireland
- Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland
| | - Gordon O' Brien
- Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland
| | - Robert D Johnston
- Trinity Centre for Biomedical Engineering, Trinity College Dublin, Dublin, Ireland
- Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland
- Advanced Materials and Bioengineering Research Centre (AMBER), Royal College of Surgeons in Ireland and Trinity College Dublin, Dublin, Ireland
| | - Caitríona Lally
- Trinity Centre for Biomedical Engineering, Trinity College Dublin, Dublin, Ireland
- Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland
- Advanced Materials and Bioengineering Research Centre (AMBER), Royal College of Surgeons in Ireland and Trinity College Dublin, Dublin, Ireland
| |
Collapse
|
2
|
Jawli A, Nabi G, Huang Z. A Polyvinyl Alcohol (PVA)-Based Phantom for Prostate Cancer Detection Using Multiparametric Ultrasound: A Validation Study. Bioengineering (Basel) 2024; 11:1052. [PMID: 39593712 PMCID: PMC11591372 DOI: 10.3390/bioengineering11111052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2024] [Revised: 10/17/2024] [Accepted: 10/19/2024] [Indexed: 11/28/2024] Open
Abstract
Multiparametric ultrasound (mpUS) enhances prostate cancer (PCa) diagnosis by using multiple imaging modalities. Tissue-mimicking materials (TMM) phantoms, favoured over animal models for ethical and consistency reasons, were created using polyvinyl alcohol (PVA) with varying molecular weights (Mw). METHODS Four PVA samples, varying in Mw with constant concertation, were mixed with glycerol, silicon carbide (SiC), and aluminium oxide (Al2O3). Phantoms with varying depth and inclusion sizes were created and tested using shear-wave elastography (SWE). An mpUS phantom was developed to mimic prostate tissue, including isoechoic and hypoechoic inclusions and vessels. The phantom was scanned using supersonic ultrasound, strain elastography, and Doppler ultrasound. Validation was performed using radical prostatectomy data and shear-wave elastography. RESULTS The acoustic properties varied with enhancers like glycerol and Al2O3. Low Mw PVA samples had a speed of sound ranging from 1547.50 ± 2 to 1553.70 ± 2.2 m/s and attenuation of 0.61 ± 0.062 to 0.63 ± 0.05 dB/cm/MHz. High Mw PVA samples ranged from 1555 ± 2.82 to 1566 ± 4.5 m/s and 0.71 ± 0.02 to 0.73 ± 0.046 dB/cm/MHz. Young's modulus ranged from 11 ± 2 to 82.3 ± 0.5 kPa across 1 to 10 freeze-thaw cycles. Inclusion size, depth, and interaction statistically affect the SWE measurements with p-value = 0.056327, p-value = 8.0039 × 10-8, and p-value = 0.057089, respectively. SWE showed isoechoic inclusions, prostate tissue, and surrounding tissue only. The Doppler velocity was measured in three different inner diameters. CONCLUSION PVA mixed with enhancer materials creates an mpUS phantom with properties that mimic normal and abnormal prostate tissue, blood vessels, and soft tissue, facilitating advanced diagnostic training and validation.
Collapse
Affiliation(s)
- Adel Jawli
- Division of Imaging Sciences and Technology, School of Medicine, Ninewells Hospital, University of Dundee, Dundee DD1 9SY, UK
- Department of Clinical Radiology, Sheikh Jaber Al-Ahmad Al-Sabah Hospital, Ministry of Health, Sulaibikhat, Kuwait City 13001, Kuwait
| | - Ghulam Nabi
- Division of Imaging Sciences and Technology, School of Medicine, Ninewells Hospital, University of Dundee, Dundee DD1 9SY, UK
| | - Zhihong Huang
- Division of Imaging Sciences and Technology, School of Medicine, Ninewells Hospital, University of Dundee, Dundee DD1 9SY, UK
- School of Science and Engineering, University of Dundee, Dundee DD1 4HN, UK
| |
Collapse
|
3
|
Henriques J, Amaro AM, Piedade AP. Biomimicking Atherosclerotic Vessels: A Relevant and (Yet) Sub-Explored Topic. Biomimetics (Basel) 2024; 9:135. [PMID: 38534820 DOI: 10.3390/biomimetics9030135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 02/20/2024] [Accepted: 02/21/2024] [Indexed: 03/28/2024] Open
Abstract
Atherosclerosis represents the etiologic source of several cardiovascular events, including myocardial infarction, cerebrovascular accidents, and peripheral artery disease, which remain the leading cause of mortality in the world. Numerous strategies are being delineated to revert the non-optimal projections of the World Health Organization, by both designing new diagnostic and therapeutic approaches or improving the interventional procedures performed by physicians. Deeply understanding the pathological process of atherosclerosis is, therefore, mandatory to accomplish improved results in these trials. Due to their availability, reproducibility, low expensiveness, and rapid production, biomimicking physical models are preferred over animal experimentation because they can overcome some limitations, mainly related to replicability and ethical issues. Their capability to represent any atherosclerotic stage and/or plaque type makes them valuable tools to investigate hemodynamical, pharmacodynamical, and biomechanical behaviors, as well as to optimize imaging systems and, thus, obtain meaningful prospects to improve the efficacy and effectiveness of treatment on a patient-specific basis. However, the broadness of possible applications in which these biomodels can be used is associated with a wide range of tissue-mimicking materials that are selected depending on the final purpose of the model and, consequently, prioritizing some materials' properties over others. This review aims to summarize the progress in fabricating biomimicking atherosclerotic models, mainly focusing on using materials according to the intended application.
Collapse
Affiliation(s)
- Joana Henriques
- University of Coimbra, CEMMPRE, ARISE, Department of Mechanical Engineering, 3030-788 Coimbra, Portugal
| | - Ana M Amaro
- University of Coimbra, CEMMPRE, ARISE, Department of Mechanical Engineering, 3030-788 Coimbra, Portugal
| | - Ana P Piedade
- University of Coimbra, CEMMPRE, ARISE, Department of Mechanical Engineering, 3030-788 Coimbra, Portugal
| |
Collapse
|
4
|
Mobadersany N, Liang P, Kemper P, Konofagou EE. Polyvinyl Alcohol Phantoms With Heterogeneous Plaques: Estimation of Pulse Wave Velocity at the Stenotic Region Using Pulse Wave Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:91-98. [PMID: 37838523 PMCID: PMC11102764 DOI: 10.1016/j.ultrasmedbio.2023.09.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 09/01/2023] [Accepted: 09/08/2023] [Indexed: 10/16/2023]
Abstract
OBJECTIVE Plaque characterization is essential for stroke prevention. In the study reported herein, we describe a heterogeneous phantom manufacturing technique with varying plaque compositions of different stiffness using polyvinyl alcohol (PVA) to emulate stenotic arteries and evaluated the use of pulse wave imaging (PWI) to assess plaque stiffness by comparing derived pulse wave velocities, with the goal of assessing plaque vulnerability and identifying high-risk patients for stroke. METHODS Five stenotic phantoms (50% stenosis) were fabricated by pouring PVA solutions into 3-D-printed molds. Two of the phantoms had heterogeneous plaque compositions of soft (E0 = 13 kPa) and intermediate (E0 = 40 kPa) materials and of stiff (E0 = 54 kPa) and intermediate materials. Ultrasound sequences were acquired as the arterial phantoms were connected to a pulsating pump, and PWI was performed on the ultrasound acquisition using normalized cross-correlation to track the pulse-induced phantom wall distension propagations. Pulse wave velocities were estimated by fitting a linear regression line between the arrival time of the peak acceleration of the wall distension waveform and the corresponding location. RESULTS Arterial phantoms with heterogeneous plaque stiffness were successfully fabricated. Pulse wave velocities of 2.06, 2.21, 2.49, 2.67 and 3.31 m/s were found in the phantom experiments using PWI for homogeneous soft plaque, the heterogeneous soft and intermediate plaque, homogeneous intermediate plaque, the heterogeneous stiff and intermediate plaque and homogeneous stiff plaque, respectively. CONCLUSION A novel arterial phantom building technique was reported with varying heterogenous plaque compositions of different stiffness. The feasibility of using PWI to evaluate plaque stiffness in stenotic arteries was determined and found that PWI can distinguish between plaques of distinct stiffness and composition.
Collapse
Affiliation(s)
- Nima Mobadersany
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - Pengcheng Liang
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - Paul Kemper
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - Elisa E Konofagou
- Department of Biomedical Engineering, Columbia University, New York, NY, USA; Department of Radiology, Columbia University, New York, New York, NY, USA.
| |
Collapse
|
5
|
Cherkaoui I, Bettaibi S, Barkaoui A, Kuznik F. Toward a Mesoscopic Modeling Approach of Magnetohydrodynamic Blood Flow in Pathological Vessels: A Comprehensive Review. Ann Biomed Eng 2023; 51:2415-2440. [PMID: 37639179 DOI: 10.1007/s10439-023-03350-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Accepted: 08/01/2023] [Indexed: 08/29/2023]
Abstract
The investigation of magnetohydrodynamic (MHD) blood flow within configurations that are pertinent to the human anatomy holds significant importance in the realm of scientific inquiry because of its practical implications within the medical field. This article presents an exhaustive appraisal of the diverse applications of magnetohydrodynamics and their computational modeling in biological contexts. These applications are classified into two categories: simple flow and pulsatile flow. An alternative approach of traditional CFD methods called Lattice Boltzmann Method (LBM), a mesoscopic method based on kinetic theory, is introduced to solve complex problems, such as hemodynamics. The results show that the flow velocity reduces considerably by increasing the magnetic field intensity, and the flow separation area is minimized by the increase of magnetic field strength. The LBM with BGK collision model has shown good results in terms of precision. Finally, this literature review has revealed a number of potential avenues for further research. Suggestions for future works are proposed accordingly.
Collapse
Affiliation(s)
- Ikram Cherkaoui
- Laboratoire des Energies Renouvelable et Matériaux Avancés, Université Internationale de Rabat (UIR), Rocade Rabat-Salé, 11100, Rabat, Morocco
| | - Soufiene Bettaibi
- Laboratoire des Energies Renouvelable et Matériaux Avancés, Université Internationale de Rabat (UIR), Rocade Rabat-Salé, 11100, Rabat, Morocco.
| | - Abdelwahed Barkaoui
- Laboratoire des Energies Renouvelable et Matériaux Avancés, Université Internationale de Rabat (UIR), Rocade Rabat-Salé, 11100, Rabat, Morocco
| | | |
Collapse
|
6
|
Mobadersany N, Meshram NH, Kemper P, Sise CV, Karageorgos GM, Liang P, Ateshian GA, Konofagou EE. Pulse wave imaging of a stenotic artery model with plaque constituents of different stiffnesses: Experimental demonstration in phantoms and fluid-structure interaction simulation. J Biomech 2023; 149:111502. [PMID: 36842406 PMCID: PMC10392770 DOI: 10.1016/j.jbiomech.2023.111502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 02/03/2023] [Accepted: 02/13/2023] [Indexed: 02/18/2023]
Abstract
Vulnerable plaques associated with softer components may rupture, releasing thrombotic emboli to smaller vessels in the brain, thus causing an ischemic stroke. Pulse Wave Imaging (PWI) is an ultrasound-based method that allows for pulse wave visualization while the regional pulse wave velocity (PWV) is mapped along the arterial wall to infer the underlying wall compliance. One potential application of PWI is the non-invasive estimation of plaque's mechanical properties for investigating its vulnerability. In this study, the accuracy of PWV estimation in stenotic vessels was investigated by computational simulation and PWI in validation phantoms to evaluate this modality for assessing future stroke risk. Polyvinyl alcohol (PVA) phantoms with plaque constituents of different stiffnesses were designed and constructed to emulate stenotic arteries in the experiment, and the novel fabrication process was described. Finite-element fluid-structure interaction simulations were performed in a stenotic phantom model that matched the geometry and parameters of the experiment in phantoms. The peak distension acceleration of the phantom wall was tracked to estimate PWV. PWVs of 2.57 ms-1, 3.41 ms-1, and 4.48 ms-1 were respectively obtained in the soft, intermediate, and stiff plaque material in phantoms during the experiment using PWI. PWVs of 2.10 ms-1, 3.33 ms-1, and 4.02 ms-1 were respectively found in the soft, intermediate, and stiff plaque material in the computational simulation. These results demonstrate that PWI can effectively distinguish the mechanical properties of plaque in phantoms as compared to computational simulation.
Collapse
Affiliation(s)
- Nima Mobadersany
- Department of Biomedical Engineering, Columbia University, New York, NY, United States
| | - Nirvedh H Meshram
- Department of Biomedical Engineering, Columbia University, New York, NY, United States
| | - Paul Kemper
- Department of Biomedical Engineering, Columbia University, New York, NY, United States
| | - C V Sise
- Department of Biomedical Engineering, Columbia University, New York, NY, United States
| | | | - Pengcheng Liang
- Department of Biomedical Engineering, Columbia University, New York, NY, United States
| | - Gerard A Ateshian
- Department of Biomedical Engineering, Columbia University, New York, NY, United States; Department of Mechanical Engineering, Columbia University, New York, NY, United States
| | - Elisa E Konofagou
- Department of Biomedical Engineering, Columbia University, New York, NY, United States; Department of Radiology, Columbia University, New York, New York, NY, United States.
| |
Collapse
|
7
|
Wajihah SA, Sankar DS. A review on non-Newtonian fluid models for multi-layered blood rheology in constricted arteries. ARCHIVE OF APPLIED MECHANICS = INGENIEUR-ARCHIV 2023; 93:1771-1796. [PMID: 36743075 PMCID: PMC9886544 DOI: 10.1007/s00419-023-02368-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 01/13/2023] [Indexed: 06/18/2023]
Abstract
Haemodynamics is a branch of fluid mechanics which investigates the features of blood when it flows not only via blood vessels of smaller/larger diameter, but also under normal as well as abnormal flow states, such as in the presence of stenosis, aneurysm, and thrombosis. This review aims to discuss the rheological properties of blood, geometry of constrictions, dilations and the emergence of single-layered fluid to four-layered fluid models. To discuss further the influence of the aforesaid parameters on the physiologically important flow quantities, the mathematical formulation and solution methodology of the two-layered and four layered arterial blood flow problems studied by the authors (Afiqah and Sankar in ARPN J Eng Appl Sci 15:1129--1143, 2020, Comput Methods Programs Biomed 199:105907, 2021. 10.1016/j.cmpb.2020.105907) are recalled. It should be pointed out that the increasing resistive impedance to flow in three distinct states encompassing healthy, anaemic, and diabetic demonstrates that the greater the restriction in the artery, very few blood is carried to the pathetic organs, leading to subjects' death. It is also discovered that the pulsatile nature of blood movement produces a dynamic environment that poses a slew of intriguing and unstable fluid mechanical state. It is hoped that the intriguing results gathered from this literature survey and review conducted may help the medical practitioners to forecast blood behaviour mobility in stenotic arteries. Furthermore, the physiological information gathered from the available clinical data from the literature on patients diagnosed with diabetes and anaemia may be beneficial to doctors in deciding the therapeutic procedure for treating some particular cardiovascular disease.
Collapse
Affiliation(s)
- S. Afiqah Wajihah
- Applied Mathematics and Economics Programme Area, School of Applied Sciences and Mathematics, Universiti Teknologi Brunei, Jalan Tungku Link, Gadong, Bandar Seri Begawan, BE1410 Brunei Darussalam
| | - D. S. Sankar
- Applied Mathematics and Economics Programme Area, School of Applied Sciences and Mathematics, Universiti Teknologi Brunei, Jalan Tungku Link, Gadong, Bandar Seri Begawan, BE1410 Brunei Darussalam
| |
Collapse
|
8
|
Dakok KK, Matjafri MZ, Suardi N, Oglat AA, Nabasu SE. A Review of Carotid Artery Phantoms for Doppler Ultrasound Applications. J Med Ultrasound 2021; 29:157-166. [PMID: 34729323 PMCID: PMC8515632 DOI: 10.4103/jmu.jmu_164_20] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 01/19/2021] [Accepted: 02/25/2021] [Indexed: 11/19/2022] Open
Abstract
Ultrasound imaging systems need tissue-mimicking phantoms with a good range of acoustic properties. Many studies on carotid artery phantoms have been carried out using ultrasound; hence this study presents a review of the different forms of carotid artery phantoms used to examine blood hemodynamics by Doppler ultrasound (DU) methods and explains the ingredients that constitute every phantom with their advantages and disadvantages. Different research databases were consulted to access relevant information on carotid artery phantoms used for DU measurements after which the information were presented systematically spanning from walled phantoms to wall-less phantoms. This review points out the fact that carotid artery phantoms are made up of tissue mimicking materials, vessel mimicking materials, and blood mimicking fluid whose properties matched those of real human tissues and vessels. These materials are a combination of substances such as water, gelatin, glycerol, scatterers, and other powders in their right proportions.
Collapse
Affiliation(s)
- Kyermang Kyense Dakok
- Department of Medical Physics and Radiation Science, School of Physics, Univirsti Sains Malaysia, Penang Malaysia, Nigeria
| | - Mohammed Zubir Matjafri
- Department of Medical Physics and Radiation Science, School of Physics, Univirsti Sains Malaysia, Penang Malaysia, Nigeria
| | - Nursakinah Suardi
- Department of Medical Physics and Radiation Science, School of Physics, Univirsti Sains Malaysia, Penang Malaysia, Nigeria
| | - Ammar Anwar Oglat
- Department of Medical Imaging, Faculty of Applied Medical Sciences, The Hashemite University, Zarqa, Joradan, Nigeria
| | - Seth Ezra Nabasu
- Department of Physics, Plateau State University Bokkos, Plateau State, Nigeria
| |
Collapse
|
9
|
Chee AJY, Ishii T, Yiu BYS, Yu ACH. Helical toroid phantom for 3D flow imaging investigations. Phys Med Biol 2021; 66:045029. [PMID: 33586671 DOI: 10.1088/1361-6560/abda99] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The medical physics community has hitherto lacked an effective calibration phantom to holistically evaluate the performance of three-dimensional (3D) flow imaging techniques. Here, we present the design of a new omnidirectional, three-component (3-C) flow phantom whose lumen is consisted of a helical toroid structure (4 mm lumen diameter; helically winded for 5 revolutions over a torus with 10 mm radius; 5 mm helix radius). This phantom's intraluminal flow trajectory embraces all combinations of x, y, and z directional components, as confirmed using computational fluid dynamics (CFD) simulations. The phantom was physically fabricated via lost-core casting with polyvinyl alcohol cryogel (PVA) as the tissue mimic. 3D ultrasound confirmed that the phantom lumen expectedly resembled a helical toroid geometry. Pulsed Doppler measurements showed that the phantom, when operating under steady flow conditions (3 ml s-1 flow rate), yielded flow velocity magnitudes that agreed well with those derived from CFD at both the inner torus (-47.6 ± 5.7 versus -52.0 ± 2.2 cm s-1; mean ± 1 S.D.) and the outer torus (49.5 ± 4.2 versus 48.0 ± 1.7 cm s-1). Additionally, 3-C velocity vectors acquired from multi-angle pulsed Doppler showed good agreement with CFD-derived velocity vectors (<7% and 10° difference in magnitude and flow angle, respectively). Ultrasound color flow imaging further revealed that the phantom's axial flow pattern was aligned with the CFD-derived flow profile. Overall, the helical toroid phantom has strong potential as an investigative tool in 3D flow imaging innovation endeavors, such as the development of flow vector estimators and visualization algorithms.
Collapse
Affiliation(s)
- Adrian J Y Chee
- Schlegel Research Institute for Aging and Department of Electrical and Computer Engineering, University of Waterloo, Waterloo ON, Canada
| | | | | | | |
Collapse
|
10
|
Abstract
Atherosclerosis is one of the main causes of cardiovascular events, namely, myocardium infarction and cerebral stroke, responsible for a great number of deaths every year worldwide. This pathology is caused by the progressive accumulation of low-density lipoproteins, cholesterol, and other substances on the arterial wall, narrowing its lumen. To date, many hemodynamic studies have been conducted experimentally and/or numerically; however, this disease is not yet fully understood. For this reason, the research of this pathology is still ongoing, mainly, resorting to computational methods. These have been increasingly used in biomedical research of atherosclerosis because of their high-performance hardware and software. Taking into account the attempts that have been made in computational techniques to simulate realistic conditions of blood flow in both diseased and healthy arteries, the present review aims to give an overview of the most recent numerical studies focused on coronary arteries, by addressing the blood viscosity models, and applied physiological flow conditions. In general, regardless of the boundary conditions, numerical studies have been contributed to a better understanding of the development of this disease, its diagnosis, and its treatment.
Collapse
|
11
|
Carvalho V, Maia I, Souza A, Ribeiro J, Costa P, Puga H, Teixeira S, Lima RA. In vitro
Biomodels in Stenotic Arteries to Perform Blood Analogues Flow Visualizations and Measurements: A Review. Open Biomed Eng J 2020. [DOI: 10.2174/1874120702014010087] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Cardiovascular diseases are one of the leading causes of death globally and the most common pathological process is atherosclerosis. Over the years, these cardiovascular complications have been extensively studied by applying in vivo, in vitro and numerical methods (in silico). In vivo studies represent more accurately the physiological conditions and provide the most realistic data. Nevertheless, these approaches are expensive, and it is complex to control several physiological variables. Hence, the continuous effort to find reliable alternative methods has been growing. In the last decades, numerical simulations have been widely used to assess the blood flow behavior in stenotic arteries and, consequently, providing insights into the cardiovascular disease condition, its progression and therapeutic optimization. However, it is necessary to ensure its accuracy and reliability by comparing the numerical simulations with clinical and experimental data. For this reason, with the progress of the in vitro flow measurement techniques and rapid prototyping, experimental investigation of hemodynamics has gained widespread attention. The present work reviews state-of-the-art in vitro macro-scale arterial stenotic biomodels for flow measurements, summarizing the different fabrication methods, blood analogues and highlighting advantages and limitations of the most used techniques.
Collapse
|
12
|
He Z, Mongrain R, Lessard S, Chayer B, Cloutier G, Soulez G. Anthropomorphic and biomechanical mockup for abdominal aortic aneurysm. Med Eng Phys 2020; 77:60-68. [PMID: 31954613 DOI: 10.1016/j.medengphy.2019.12.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Revised: 09/08/2019] [Accepted: 12/15/2019] [Indexed: 11/16/2022]
Abstract
Abdominal aortic aneurysm (AAA) is an asymptomatic condition due to the dilation of abdominal aorta along with progressive wall degeneration, where rupture of AAA is life-threatening. Failures of AAA endovascular repair (EVAR) reflect our inadequate knowledge about the complex interaction between the aortic wall and medical devices. In this regard, we are presenting a hydrogel-based anthropomorphic mockup (AMM) to better understand the biomechanical constraints during EVAR. By adjusting the cryogenic treatments, we tailored the hydrogel to mimic the mechanical behavior of human AAA wall, thrombus and abdominal fat. A specific molding sequence and a pressurizing system were designed to reproduce the geometrical and diseased characteristics of AAA. A mechanically, anatomically and pathologically realistic AMM for AAA was developed for the first time, EVAR experiments were then performed with and without the surrounding fat. Substantial displacements of the aortic centerlines and vessel expansion were observed in the case without surrounding fat, revealing an essential framework created by the surrounding fat to account for the interactions with medical devices. In conclusion, the importance to consider surrounding tissue for the global deformation of AAA during EVAR was highlighted. Furthermore, potential use of this AMM for medical training was also suggested.
Collapse
Affiliation(s)
- Zinan He
- McGill University, 845 Sherbrooke Street West, Montréal, Québec H3A 0G4, Canada; Centre de recherche du Centre hospitalier de l'Université de Montréal (CRCHUM), 900 Rue Saint-Denis, Montréal, Québec H2X 0A9, Canada
| | - Rosaire Mongrain
- McGill University, 845 Sherbrooke Street West, Montréal, Québec H3A 0G4, Canada
| | - Simon Lessard
- Centre de recherche du Centre hospitalier de l'Université de Montréal (CRCHUM), 900 Rue Saint-Denis, Montréal, Québec H2X 0A9, Canada
| | - Boris Chayer
- Centre de recherche du Centre hospitalier de l'Université de Montréal (CRCHUM), 900 Rue Saint-Denis, Montréal, Québec H2X 0A9, Canada
| | - Guy Cloutier
- Centre de recherche du Centre hospitalier de l'Université de Montréal (CRCHUM), 900 Rue Saint-Denis, Montréal, Québec H2X 0A9, Canada; Université de Montréal, 2900 Boulevard Edouard-Montpetit, Montréal, Québec H3T 1J4, Canada
| | - Gilles Soulez
- Centre de recherche du Centre hospitalier de l'Université de Montréal (CRCHUM), 900 Rue Saint-Denis, Montréal, Québec H2X 0A9, Canada; Université de Montréal, 2900 Boulevard Edouard-Montpetit, Montréal, Québec H3T 1J4, Canada.
| |
Collapse
|